Enhanced Component Performance Study: Turbine-Driven Pumps 1998-2024
Ma, Zhegang, Zhang, Sai · 2026
Read Enhanced Component Performance Study: Turbine-Driven Pumps 1998-2024 by Ma, Zhegang, Zhang, Sai (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/doe-osti-3364334-enhanced-component-performance-study-tur.txt.
Description
Idaho National Laboratory report INL/RPT-25-86867, by Zhegang Ma and Sai Zhang and dated July 2025, evaluates turbine-driven pump reliability at U.S. commercial nuclear plants for the Nuclear Regulatory Commission. Turbine-driven pumps matter in emergencies because steam, not electricity, powers them. Failure records from the industry reporting system cover 1998 through 2024, split into fail-to-start and fail-to-run modes for standby and normally running service.
Trends over the most recent ten years mostly improved. The standby fail-to-run rate beyond one hour fell, the normally running fail-to-run rate fell, and total 24-hour unreliability for standby pumps fell. Demands, run hours, and failure events for normally running pumps also declined. Yearly data tables back every figure, giving risk analysts updated failure rates for plant safety models.
Catalog record
| CREATOR | Ma, Zhegang, Zhang, Sai |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 120 KB |
| LICENSE | Public Domain |
| RIGHTS | PUBLIC DOMAIN |
| SOURCE | DOE OSTI |