INL/RPT-25-86867 Enhanced Component Performance Study: Turbine-Driven Pumps 1998–2024 JULY 2025 Zhegang Ma and Sai Zhang Idaho National Laboratory INL/RPT-25-86867 Enhanced Component Performance Study: Turbine-Driven Pumps 1998–2024 Zhegang Ma and Sai Zhang Idaho National Laboratory July 2025 Idaho National Laboratory Idaho Falls, Idaho 83415 http://www.inl.gov Prepared for the Division of Risk Analysis Office of Nuclear Regulatory Research U.S. Nuclear Regulatory Commission NRC Agreement Number 31310024S0038 Page intentionally left blank ABSTRACT This report presents an enhanced performance evaluation of turbine-driven pumps (TDPs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from calendar year 1998 through 2024 as reported in the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS). The TDP failure modes considered for standby systems are fail to start (FTS), fail to run (FTR) for 1 hour of operation (FTR≤1H), FTR after 1 hour of operation (FTR>1H), and for normally running systems FTS and FTR. A 24-hour total unreliability estimate is also calculated and trended. The component reliability estimates and the reliability data are trended for the most recent 10-year period, while yearly estimates for reliability are provided for the entire study period. The following reliability trends in component failure probabilities, failure rates, unavailability, and total reliability were identified for TDPs for the most recent 10-year period. • Standby TDP FTR>1H failure rate—decreasing • Normally running TDP FTR failure rate—decreasing • Standby TDP total unreliability (24-hour mission)—decreasing. The following engineering trends in demands, run hours, and failure events were identified for TDPs for the most recent 10-year period: • Standby TDP frequency of FTR>1H events (events per reactor year)—decreasing • Normally running TDP frequency of start demands (demands per reactor year)— decreasing • Normally running TDP frequency of run hours (hours per reactor year)—decreasing • Normally running TDP frequency of FTR events (events per reactor year)—decreasing. v Page intentionally left blank vi CONTENTS ABSTRACT .................................................................................................................................................. v ACRONYMS ............................................................................................................................................... xi 1. INTRODUCTION............................................................................................................................... 1 2. SUMMARY OF FINDINGS .............................................................................................................. 3 2.1. Reliability Trends ..................................................................................................................... 3 2.2. Engineering Trends .................................................................................................................. 3 2.3. Consistency Check Results ...................................................................................................... 3 3. FAILURE PROBABILITIES AND FAILURE RATES .................................................................... 5 3.1. Overview .................................................................................................................................. 5 3.2. TDP Failure Probability and Failure Rate Trends.................................................................... 6 4. UNAVAILABILITY......................................................................................................................... 11 4.1. Overview ................................................................................................................................ 11 4.2. TDP Unavailability Trends .................................................................................................... 11 5. TDP TOTAL UNRELIABILITY TRENDS ..................................................................................... 13 6. ENGINEERING ANALYSIS ........................................................................................................... 15 6.1. Standby TDP Engineering Trends ......................................................................................... 15 6.2. Normally Running TDP Engineering Trends ........................................................................ 19 6.3. Comparison of IRIS TDP Unplanned Demand Results with Industry Results ...................... 22 6.4. TDP Engineering Analysis by Failure Modes ....................................................................... 23 7. TDP ASSEMBLY DESCRIPTION .................................................................................................. 30 8. DATA TABLES................................................................................................................................ 31 9. REFERENCES.................................................................................................................................. 50 vii FIGURES Figure 1. Failure probability estimate trend for standby TDP FTS. ............................................................. 8 Figure 2. Failure probability estimate trend for standby TDP FTR≤1H. ...................................................... 8 Figure 3. Failure rate estimate trend for standby TDP FTR>1H. ................................................................. 9 Figure 4. Failure probability estimate trend for normally running TDP FTS. .............................................. 9 Figure 5. Failure rate estimate trend for normally running TDP FTR. ....................................................... 10 Figure 6. Pooled standby TDP UA trend. ................................................................................................... 12 Figure 7. Standby TDP total unreliability trend (24-hour mission). ........................................................... 13 Figure 8. Normally running TDP total unreliability trend (24-hour mission). ........................................... 14 Figure 9. Frequency of start demands (demands per reactor year) for standby TDPs. ............................... 16 Figure 10. Frequency of run ≤ 1H hours (hours per reactor year) trend for standby TDPs. ....................... 16 Figure 11. Frequency of run > 1H hours (hours per reactor year) trend for standby TDPs. ....................... 17 Figure 12. Frequency of FTS events (events per reactor year) trend for standby TDPs. ............................ 17 Figure 13. Frequency of FTR≤1H events (events per reactor year) trend for standby TDPs. .................... 18 Figure 14. Frequency of FTR>1H events (events per reactor year) trend for standby TDPs. .................... 18 Figure 15. Frequency of start demands (demands per reactor year) trend for normally running TDPs. .......................................................................................................................................... 20 Figure 16. Frequency of run hours (hours per reactor year) trend for normally running TDPs.................. 21 Figure 17. Frequency of FTS events (events per reactor year) trend for normally running TDPs. ............ 21 Figure 18. Frequency of FTR events (events per reactor year) trend for normally running TDPs. ............ 22 Figure 19. TDP failure event breakdown by subcomponent, failure mode, and operational status............ 26 Figure 20. TDP failure event breakdown by cause group, failure mode, and operational status. ............... 27 Figure 21. TDP failure event breakdown by failure detection method, failure mode, and operational status. ....................................................................................................................... 28 Figure 22. TDP failure event breakdown by recoverability determination, failure mode, and operational status. ....................................................................................................................... 29 viii TABLES Table 1. TDP systems. .................................................................................................................................. 5 Table 2. Industry-wide distributions of p (failure probability) and λ (hourly rate) in the 2020 Parameter Update for TDPs [7]. .................................................................................................. 5 Table 3. Industry-average distributions of unavailability in the 2020 Parameter Update [7] for TDPs. .......................................................................................................................................... 11 Table 4. Summary of TDP failure counts for the FTS failure mode over time by system. ........................ 19 Table 5. Summary of TDP failure counts for the FTR≤1H failure mode over time by system. ................. 19 Table 6. Summary of TDP failure counts for the FTR>1H and FTR failure modes over time by system. ........................................................................................................................................ 19 Table 7. Standby TDP unplanned demand performance comparison with industry-average performance. ............................................................................................................................... 23 Table 8. Component failure cause groups. .................................................................................................. 24 Table 9. Plot data for Figure 1, failure probability estimate trend for standby TDP FTS........................... 32 Table 10. Plot data for Figure 2, failure probability estimate trend for standby TDP FTR≤1H. ................ 33 Table 11. Plot data for Figure 3, failure rate estimate trend for standby TDP FTR>1H. ........................... 34 Table 12. Plot data for Figure 4, failure probability estimate trend for normally running TDP FTS. ........ 35 Table 13. Plot data for Figure 5, failure rate estimate trend for normally running TDP FTR. ................... 36 Table 14. Plot data for Figure 6, pooled standby TDP UA trend................................................................ 37 Table 15. Plot data for Figure 7, standby TDP total unreliability trend (24-hour mission). ....................... 38 Table 16. Plot data for Figure 8, normally running TDP total unreliability trend (24-hour mission). ..................................................................................................................................... 39 Table 17. Plot data for Figure 9, frequency of start demands (demands per reactor year) trend for standby TDPs.............................................................................................................................. 40 Table 18. Plot data for Figure 10, frequency of run ≤ 1H hours (hours per reactor year) trend for standby TDPs.............................................................................................................................. 41 Table 19. Plot data for Figure 11, frequency of run > 1H hours (hours per reactor year) trend for standby TDPs.............................................................................................................................. 42 Table 20. Plot data for Figure 12, frequency of FTS events (events per reactor year) trend for standby TDPs.............................................................................................................................. 43 Table 21. Plot data for Figure 13, frequency of FTR≤1H events (events per reactor year) trend for standby TDPs.............................................................................................................................. 44 Table 22. Plot data for Figure 14, frequency of FTR>1H events (events per reactor year) trend for standby TDPs.............................................................................................................................. 45 Table 23. Plot data for Figure 15, frequency of start demands (demands per reactor year) trend for normally running TDPs. ............................................................................................................. 46 Table 24. Plot data for Figure 16, frequency of run hours (hours per reactor year) trend for normally running TDPs. ............................................................................................................. 47 ix Table 25. Plot data for Figure 17, frequency of FTS events (events per reactor year) trend for normally running TDPs. ............................................................................................................. 48 Table 26. Plot data for Figure 18, frequency of FTR events (events per reactor year) trend for normally running TDPs. ............................................................................................................. 49 x ACRONYMS AFW auxiliary feed water AOV air-operated valve CCF common-cause failure CNID constrained noninformative prior distribution EDG emergency diesel generator EPIX Equipment Performance and Information Exchange EPS emergency power supply ESF engineered safety feature FTR≤1H fail to run for 1 hour of operation FTR>1H fail to run after 1 hour of operation FTR fail to run FTS fail to start HPCI high-pressure coolant injection HPCS high-pressure core spray ICES INPO Consolidated Events Database INL Idaho National Laboratory INPO Institute of Nuclear Power Operations IRIS Industry Reporting and Information System MDP motor-driven pump MFW main feed water MOV motor-operated valve MSPI Mitigating Systems Performance Index NPRDS Nuclear Plant Reliability Data System NRC Nuclear Regulatory Commission OLS ordinary least squares PMT post maintenance testing PRA probabilistic risk assessment RCIC reactor core isolation cooling SPAR standardized plant analysis risk TDP turbine-driven pump UA unavailability xi Page intentionally left blank xii Enhanced Component Performance Study: Turbine-Driven Pumps 1998–2024 1. INTRODUCTION This report presents an enhanced performance evaluation of turbine-driven pumps (TDPs) at U.S. commercial nuclear power plants from 1998 through 2024. The objective of each updated component performance study is to obtain annual performance trends of failure rates and probabilities and to present an analysis of factors that could influence the component trends. This year’s update continues with the two changes implemented in the 2016 update that are different from earlier updates: (1) the update results are based on calendar year instead of the federal fiscal year, and (2) the failure events included in the update are “hard” failures (i.e., the p-valuesa indicating the likelihood the component would have failed during a 24-hour mission are 1.0). Previous updates (2015 and before) included events with lower p- values, indicating degraded conditions that probably would have caused failure during a 24-hour mission but were not quite hard failures at their outset. The enhanced component performance studies are conducted for the following component types: air-operated valves (AOVs), emergency diesel generators (EDGs), motor-driven pumps (MDPs), motor-operated valves (MOVs), and TDPs. The TDP performance analysis was originally published as NUREG-1715, Volume 1, in April 2000 [1], and then updated annually (from 2002 to 2014) or every other year (since 2016) in a series of reports, with the last one being documented in INL/RPT-23-73957, Enhanced Component Performance Study: Turbine-Driven Pumps 1998-2022 [2]. The Nuclear Regulatory Commission (NRC) Reactor Operational Experience Results and Databases web page provides the link to the historical and current results of component performance studies (http://nrcoe.inl.gov/CompPerf). An overview of the trending methods, glossary of terms, and abbreviations is documented in the paper Overview and Reference Document for Operational Experience Results and Databases Trending, referred to in this report as Overview and Reference [3], that can also be found from https://nrcoe.inl.gov/. The data used in this study are based on the operating experience failure reports from Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS) [4], formerly the Equipment Performance and Information Exchange Database (EPIX) and INPO Consolidated Events Database (ICES) [5]. Maintenance unavailability (UA) performance data came from the Reactor Oversight Process program’s Mitigating Systems Performance Index (MSPI) program [6] and IRIS. Previously, the study relied on operating experience obtained from licensee event reports, Nuclear Plant Reliability Data System (NPRDS), and EPIX. The IRIS database, which includes the MSPI designated devices as a subset, has matured to the point where both component availability and reliability can be estimated with a high degree of accuracy. TDPs are categorized as either standby or normally running. The TDP failure modes considered for standby systems are fail to start (FTS), fail to run (FTR) for 1 hour of operation (FTR≤1H), and FTR after 1 hour of operation (FTR>1H). The TDP failure modes considered for normally running systems are FTS and FTR. Annual failure probabilities (failures per demand) are provided for FTS and FTR≤1H events. Annual failure rates (failures per run hour) are provided for FTR > 1H and FTR events. TDP train maintenance unavailability probabilities are also considered. In addition to the presentation of the component failure mode data and the UA data, a 24-hour total unreliability is calculated and trended. a The “p-values” here refer to the component degradation values, which indicate the extent of a component's failure as a probability that the degree of degradation would have led to failure during system operation. This is different from the “p- value” used for statistical tests in the remainder of the report. 1 Each of the estimates is trended for the most recent 10-year period, while yearly estimates are provided for the entire study period. While this report provides an overview of operational data and evaluates component performance over time, it makes no attempt to estimate values for use in probabilistic risk assessments (PRAs) or Standardized Plant Analysis Risk (SPAR) models. INL/EXT-21-65055, Industry-Average Performance for Components and Initiating Events at U.S. Commercial Nuclear Power Plants: 2020 Update, referred to in this report as the 2020 Parameter Update [7], is the most recent update to NUREG/CR-6928, Industry-Average Performance for Components and Initiating Events at U.S Commercial Nuclear Power Plants [8], using data through 2020, and provides component unreliability estimates for SPAR models.b Estimates from that report are included herein for comparison. Those estimates are labeled “SPAR 2020” in the associated tables and figures. Section 2 of this report presents the summary of findings from the study, with particular emphasis on the existence of any statistically significant increasing or decreasing trends in component performances. Section 3 provides the annual estimates of failure probabilities and rates related to TDPs as well as the trend analysis of the estimates. Section 4 provides TDP train UA estimates and their trends. Section 5 estimates the annual total unreliability and the trends for TDPs. Section 6 presents various engineering analyses performed for TDPs, such as the trend for demands or run hours per plant reactor year, the trend for events per plant reactor year, and the breakdown of TDP failures by subcomponents, failure causes, detection methods, and recovery possibility. A comparison of IRIS TDP unplanned demand results with the 2020 Parameter Update for standby TDPs is also conducted in Section 6 in order to determine whether the current data are consistent with the estimated values used in PRA. Section 7 provides the TDP assembly information. Section 8 presents the plot data for various figures in previous sections. b Appendix B of INL/RPT-25-86864, Enhanced Component Performance Study: Emergency Diesel Generators 1998–2024 [12], provides a comparative overview of the three primary update activities under the NRC’s operating experience data analysis program: the SPAR Parameter Update, the Component Performance Study Update, and the System Study Update. It summarizes their respective purposes, methodologies, data periods, and other key considerations. 2 2. SUMMARY OF FINDINGS The results of this study are summarized in this section. Of particular interest is the existence of any statistically significantc reliability trends in component failure probabilities, failure rates, unavailability, and total reliability. Engineering trends in component demands, run hours, and failure events provide additional insights. 2.1. Reliability Trends • An extremely statistically significant decreasing trend was identified in the standby TDP FTR>1H failure rate estimates with a p-value of 0.0006. The same trend was observed in the 2022 and 2020 TDP update studies [2], [9] as highly statistically significant or statistically significant. • An extremely statistically significant decreasing trend was identified in normally running TDP FTR failure rate estimates with a p-value of 0.0004. The same trend was observed in the 2022 TDP update study [2] as highly statistically significant. • An extremely statistically significant decreasing trend was identified in the standby TDP total unreliability (24-hour mission) estimates with a p-value of 0.001. The same trend was observed in the 2022 and 2020 TDP update studies [2], [9] as extremely or highly statistically significant. 2.2. Engineering Trends • An extremely statistically significant decreasing trend was identified in the standby TDP frequency of FTR>1H events (events per reactor year) estimates with a p-value of 0.0003. The same trend was observed in the 2022 and 2020 TDP update studies [2], [9] as extremely or highly statistically significant. • A statistically significant decreasing trend was identified in normally running TDP frequency of start demands (demands per reactor year) estimates with a p-value of 0.037. The same trend was observed in the 2022, 2020, and 2016 TDP update studies [2], [9], [10] as extremely or highly statistically significant. • A statistically significant decreasing trend was identified in the normally running TDP frequency of run hours (hours per reactor year) estimates with a p-value of 0.027. The same trend was observed in the 2022, 2020, and 2016 TDP update studies [2], [9], [10] as extremely or highly statistically significant. • An extremely statistically significant decreasing trend was identified in the normally running TDP frequency of FTR events (events per reactor year) estimates with a p-value of 0.0004. The same trend was observed in the 2022 TDP update study [2] as highly statistically significant. 2.3. Consistency Check Results An ongoing concern in the industry is whether a combination of test demand, non-test demand, and engineered safety feature (ESF) demand data produces failure estimates that adequately predict standby component performance during unplanned demands (i.e., non-test and ESF demands). Section 6.3 provides the results of consistency checks that compare failure predictions obtained via simulation tests on industry-average parameters from the 2020 Parameter Update against operational failure counts obtained from actual TDP performance with ESF demands. These consistency checks show that the FTS and FTR>1H failure observations in the unplanned demand data lie within the corresponding c. Statistically significant is defined in terms of the p-value. A p-value is a probability indicating whether to accept or reject the null hypothesis that there is no trend in the data. P-values of less than or equal to 0.05 indicate that we are 95% confident there is a trend in the data (reject the null hypothesis of no trend.) By convention, we use the “Michelin Guide” scale: p-value < 0.05 (statistically significant), p-value < 0.01 (highly statistically significant), and p-value < 0.001 (extremely statistically significant). 3 industry-average failure estimate distributions, provided in the 2020 Parameter Update, that were based on both test and unplanned demands. However, the FTR≤1H failure observations are not consistent with the industry-average failure estimate distributions, which means that the TDP performs worse on an actual non-test or ESF demand than on a test demand. 4 3. FAILURE PROBABILITIES AND FAILURE RATES 3.1. Overview TDPs are categorized as either standby or normally running. The industry-wide failure probabilities and failure rates have been calculated from the operating experience for standby pump FTS, FTR≤1H, and FTR>1H, and for normally running pumps FTS and FTR. The TDP data set obtained from IRIS includes TDPs in the systems listed in Table 1. This report follows the definition of these categories in previous studies, which determines the status by evaluating the number of run-hours per demand. The pumps with low run-hours per demand (≤360) are considered standby, while those with higher run-hours per demand (>360) are considered normally running. Table 2 shows industry-wide failure probability and failure rate results for the TDP from 2020 Parameter Update [7]. The 2020 Parameter Update results are provided for comparison purposes and are important because they are intended for use in PRA. The results in this section demonstrate the extent to which the 2020 Parameter Update results remain suitable estimates for use in PRA by examining whether there are any statistically significant trends existing in industry-wide annual failure probabilities and failure rates. The TDPs are assumed to operate both when the reactor is critical and during shutdown periods with sufficient steam pressure. The number of TDPs in operation is the number of pumps that have been in operation at any time during the study period. New devices put in service during the period are included, as are devices that were in service at one time but have since been removed from service. All demand types are considered—testing, non-testing, and, as applicable, ESF demands. Non-test demands are those actual plant demands that are not ESF demands. Table 1. TDP systems. System Description Total Normally Running Standby AFW Auxiliary feed water 75 — 75 HPCI High-pressure coolant injection 28 — 28 MFW Main feed water 43 43 — RCIC Reactor core isolation cooling 31 — 31 Total 177 43 134 Table 2. Industry-wide distributions of p (failure probability) and λ (hourly rate) in the 2020 Parameter Update for TDPs [7]. Failure Distribution Operation 5% Median Mean 95% Mode Type   Standby FTS 4.59E-4 4.02E-3 5.32E-3 1.47E-2 Beta 1.26 2.35E+02 FTR≤1H 5.17E-6 1.04E-3 2.56E-3 1.03E-2 Gamma 0.44 1.73E+02 FTR>1H 1.23E-5 2.56E-3 6.35E-3 2.55E-2 Gamma 0.44 6.95E+01 Running/ FTS 5.45E-5 2.52E-3 4.60E-3 1.62E-2 Beta 0.63 1.37E+02 Alternating FTR 2.53E-7 5.37E-6 8.45E-6 2.71E-5 Gamma 0.82 9.76E+04 5 3.2. TDP Failure Probability and Failure Rate Trends This section estimates industry-wide annual failure probabilities and failure rates for standby and normally running TDPs in the entire study period, covering 1998 through 2024. The estimates are trended for the most recent 10-year period. The failure probability and failure rate estimates in this section were obtained from a Bayesian update process. The means from the posterior distributions were plotted for each year. The 5th and 95th percentiles from the posterior distributions are also provided and give an indication of the relative uncertainty in the estimated parameters from year to year. When there are no failures, the interval is larger than the interval for years when there are one or more failures because of the form of the posterior variance. Each update utilizes a relatively “flat” constrained noninformative prior distribution (CNID), which has wide bounds [3], [11]. CNID is a compromise between an informative prior and the Jeffreys noninformative prior. The mean of the CNID uses prior belief and is based on a pooling of the component or event type data for the years going into the plot, but the dispersion is defined to correspond to little information (i.e., relatively flat by set) so that the prior distributions do not create large changes in the data. For failure rates or Poisson data, the CNID is a gamma distribution, with the mean (𝜇) given by prior belief and calculated as: ∑ 𝑓𝑖 + 0.5 (1) 𝜇= ∑ 𝑇𝑖 where 𝑓𝑖 and 𝑇𝑖 are the failures and operating/standby time for the ith year, respectively. The CNID shape parameter (𝛼) is a constant number of 0.5. The posterior distribution mean for the ith year (𝜇𝑖 ) can be calculated as: 𝑓𝑖 + 0.5 (2) 𝜇𝑖 = 0.5 𝜇 + 𝑇𝑖 For failure probabilities or binomial data, the CNID is a beta distribution, with the mean given by prior belief and calculated as: ∑ 𝑓𝑖 + 0.5 (3) 𝜇= ∑ 𝐷𝑖 + 1 where 𝑓𝑖 and 𝐷𝑖 are the failures and demands for the ith year, respectively. The CNID shape parameter (𝛼) is a number between 0.3 and 0.5 based on the mean μ (see Table C.8 of [11]). The posterior distribution mean for the ith year (𝜇𝑖 ) can be calculated as: 𝑓𝑖 + 𝛼 (4) 𝜇𝑖 = 𝛼 𝜇 + 𝐷𝑖 The horizontal curves plotted around the regression lines in the graphs form 90% simultaneous confidence bands for the fitted lines. The bounds are larger than ordinary confidence bands for the individual coefficients because they form a confidence band for the entire line. In the lower left-hand corner of the trend figures, the regression p-values are reported. They come from a statistical test to assess evidence against the slope of the regression line being zero. Low p-values indicate strong evidence that the slopes are not zero and, therefore, suggest a trend does exist. P-values of less than or equal to 0.05 indicate strong evidence that there is a trend in the data (reject the null hypothesis of no trend). By 6 convention, this study uses the “Michelin Guide” scale: p-value < 0.05 (statistically significant), p-value < 0.01 (highly statistically significant), and p-value < 0.001 (extremely statistically significant). The regression methods are all based on ordinary least squares (OLS), which minimizes the residuals, or the square of the vertical distance between the annual data points and the fitted regression line. The p- values assume normal distributions for the residuals, with the same variability in the residuals across the years. In the case where the data involve failure counts, the iterative reweighted least squares method is used to account for the fact that count data are not expected to have a constant variance (e.g., the variance for Poisson-distributed counts is equal to the expected number of counts, which is expected to vary proportionally to the expected number of counts). Further information on the trending methods is provided in Section 2 of Overview and Reference [3]. A final feature of the trend graphs is that the baseline industry values from the 2020 Parameter Update (Table 2) are shown as “SPAR 2020” in the graphs for comparison. Figure 1 to Figure 5 provide the plots for industry-wide failure probabilities/rates of standby and normally running TDPs. The data for these plots are provided in Section 8: • Figure 1 shows the failure probability estimate trends for standby TDP FTS • Figure 2 shows the failure probability estimate trends for standby TDP FTR≤1H • Figure 3 shows the failure rate estimate trends for standby TDP FTR>1H • Figure 4 shows the failure probability estimate trends for normally running TDP FTS • Figure 5 shows the failure rate estimate trends for normally running TDP FTR. The following trend was identified for TDP failure probabilities/rates for FTS, FTR≤1H, FTR>1H, or FTR events in the most recent 10-year period: • Decreasing trend in the standby TDP FTR>1H failure rate estimates, which is extremely statistically significant with a p-value of 0.0006 (see Figure 3). The same trend was observed in the 2022 and 2020 TDP update studies [2], [9] as highly statistically significant or statistically significant. • Decreasing trend in the normally running TDP FTR failure rate estimates, which is highly statistically significant with a p-value of 0.0004 (see Figure 5). The same trend was observed in the 2022 TDP update study [2] as highly statistically significant. 7 Figure 1. Failure probability estimate trend for standby TDP FTS. Figure 2. Failure probability estimate trend for standby TDP FTR≤1H. 8 Figure 3. Failure rate estimate trend for standby TDP FTR>1H. Figure 4. Failure probability estimate trend for normally running TDP FTS. 9 Figure 5. Failure rate estimate trend for normally running TDP FTR. 10 4. UNAVAILABILITY 4.1. Overview The industry-wide test or maintenance UA of TDP trains has been calculated from operating experience. UA data are for TDP trains, which can include more than just the TDP. However, in most cases, the TDP contributes the majority of the UA reported. Table 3 shows overall results for the TDP from the 2020 Parameter Update [7], which is based on UA data from the IRIS database, which includes the MSPI designated devices as a subset. In the calculations, planned and unplanned unavailable hours for a train are combined. Table 3. Industry-average distributions of unavailability in the 2020 Parameter Update [7] for TDPs. Standard Description Distribution Mean Deviation TDP Test or Maintenance (AFW) Normal 4.64E-3 2.99E-03 TDP Test or Maintenance (HPCI) Normal 1.11E-2 2.77E-03 TDP Test or Maintenance (RCIC) Normal 1.01E-2 4.26E-03 TDP Test or Maintenance (All) Normal 7.30E-3 4.43E-03 4.2. TDP Unavailability Trends This section presents overall maintenance UA data for the 1998–2024 period. Note that these data do not supersede the data in Table 3 for use in risk assessments. The trend in standby TDP train unavailability is shown in Figure 6. The data for this figure is in Section 8. The TDPs in the systems with maintenance UA data currently analyzed (e.g., AFW, HPCI, and RCIC) are pooled and trended. The trend chart shows the results of using data for each year’s component UA data over time. The yearly unavailability and reactor critical hour data were obtained from the Reactor Oversight Process program (1998 to 2001) and IRIS (2002 to 2024) data for the TDP component. The total downtimes during operation for each plant and year were summed and divided by the corresponding number of TDP-reactor critical hours. UA data for shutdown periods are not reported. The mean and variance for each year is the sample mean and variance calculated from the plant-level UAs for that year. The vertical bar spans the calculated 5th to 95th percentiles of the beta distribution with matching means. For the trend graphs, a least squares fit is sought for the linear or logit model depending on which is more appropriate. Section 3 in Overview and Reference provides further information [3]. In the lower left-hand corner of the trend figures, the regression method and the p-value are reported. A review of the p-values identified no statistically significant trends in the standby TDP UA for the most recent 10-year period. 11 Figure 6. Pooled standby TDP UA trend. 12 5. TDP TOTAL UNRELIABILITY TRENDS Trends in total component unreliability are shown in Figure 7 and Figure 8. Plot data for these figures are in Section 8. Total unreliability is defined as the result of the union of the UA, FTS, FTR≤1H, and FTR>1H (or FTR) failure probabilities. The FTR>1H is calculated for 23 hours, and the FTR is calculated for 24 hours to provide the results for a 24-hour mission. Since the normally running systems TDP components do not have UA data or the FTR≤1H data, there is no UA or FTR≤1H for that calculation. The trending method is described in more detail in Section 4 of Overview and Reference [3]. In the lower left-hand corner of the trend figures, the regression method and the p-value are reported. A review of the p-value identified the following trend for the most recent 10-year period: • Decreasing trend in the standby TDP total unreliability (24-hour mission) estimates, which is extremely statistically significant with a p-value of 0.001 (see Figure 7). The same trend was observed in the 2022 and 2020 TDP update studies [2], [9] as extremely or highly statistically significant. Because there is no total unreliability estimates in the 2020 Parameter Update, there is no 2020 Parameter Update baseline industry values shown in Figure 7 and Figure 8 for comparison purpose. Figure 7. Standby TDP total unreliability trend (24-hour mission). 13 Figure 8. Normally running TDP total unreliability trend (24-hour mission). 14 6. ENGINEERING ANALYSIS This section presents various engineering analyses performed for TDP. Frequency trends of component demands, run hours, and failure events are presented in Sections 6.1 and 6.2 for standby and normally running TDPs, respectively. The data are normalized by reactor year for plants that have the equipment being trended. A comparison of IRIS TDP unplanned demand results with the industry- average results for standby TDPs is presented in Section 6.3 to determine whether the current data are consistent with the 2020 Parameter Update values used in PRA. An engineering analysis of TDP failure breakdown by failure mode and other factors is presented in Section 6.4. The factors analyzed include subcomponents, failure causes, detection methods, and recovery possibility. 6.1. Standby TDP Engineering Trends This section presents frequency trends for standby TDP demands, run hours, and failure events. The data are normalized by reactor year for plants that have the equipment being trended. The trends provide an overview of the demand counts, run hours, and failure counts associated with each failure mode across the years. Figure 9 to Figure 14 provide the plots for frequency of standby TDP start demands, run < 1H hours, run > 1H hours, FTS events, FTR≤1H events, and FTR>1H events: • Figure 9 shows the trend for standby TDP frequency of start demands (demands per reactor year) • Figure 10 shows the trend for standby TDP frequency of run ≤ 1H hours (hours per reactor year) • Figure 11 shows the trend for standby TDP frequency of run > 1H hours (hours per reactor year) • Figure 12 shows the trend for standby TDP frequency of FTS events (events per reactor year) • Figure 13 shows the trend for standby TDP frequency of FTR≤1H events (events per reactor year) • Figure 14 shows the trend for standby TDP frequency of FTR>1H events (events per reactor year). The data for the figures listed above are provided in Section 8. The standby systems from Table 1 are trended together for each figure. In the lower left-hand corner of the trend figures, the regression p-values are reported along with the prior distribution used in the Bayesian update. A review of these p-values identified the following trend for standby TDP for the most recent 10-year period: • Decreasing trend in the standby TDP frequency of FTR>1H events (events per reactor year) estimates, which is extremely statistically significant with a p-value of 0.0003 (see Figure 14). The same trend was observed in the 2022 and 2020 TDP update studies [2], [9] as extremely or highly statistically significant. Table 4 to Table 6 provide a summary of TDP (both standby and normally running) FTS, FTR≤1H, FTR>1H, and FTR failure counts by system and year during the most recent 10-year period (FTR≤1H and FTR>1H are failure modes for standby TDPs in AFW, HPCI, and RCIC systems, while FTR is the failure mode for normally running TDPs in MFW system): • Table 4 presents the TDP FTS failure counts by system and year • Table 5 presents the TDP FTR≤1H failure counts by system and year • Table 6 presents the TDP FTR>1H failure counts by system and year. 15 Figure 9. Frequency of start demands (demands per reactor year) for standby TDPs. Figure 10. Frequency of run ≤ 1H hours (hours per reactor year) trend for standby TDPs. 16 Figure 11. Frequency of run > 1H hours (hours per reactor year) trend for standby TDPs. Figure 12. Frequency of FTS events (events per reactor year) trend for standby TDPs. 17 Figure 13. Frequency of FTR≤1H events (events per reactor year) trend for standby TDPs. Figure 14. Frequency of FTR>1H events (events per reactor year) trend for standby TDPs. 18 Table 4. Summary of TDP failure counts for the FTS failure mode over time by system. Percent System TDP TDP 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 Total of Code Count Percent Failures AFW 75 42.4% 2 2 4 3 4 — 2 3 2 22 45.8% HPCI 28 15.8% — 4 1 1 4 1 1 1 — — 13 27.1% MFW 43 24.3% — 1 — — — 1 — — — — 2 4.2% RCIC 31 17.5% 1 3 2 — — 1 1 1 2 — 11 22.9% Total 177 100.0% 3 10 7 4 8 3 4 2 5 2 48 100.0% Table 5. Summary of standby TDP failure counts for the FTR≤1H failure mode over time by system. Percent System TDP TDP 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 Total of Code Count Percent Failures AFW 75 56.0% 3 1 — 1 — — — — — 1 6 35.3% HPCI 28 20.9% 1 2 — — — — 1 1 — — 5 29.4% RCIC 31 23.1% — 1 — 2 — 1 1 — — 1 6 35.3% Total 134 100.0% 4 4 0 3 0 1 2 1 0 2 17 100.0% Table 6. Summary of TDP failure counts for the FTR>1H and FTR failure modes over time by system. Percent System TDP TDP 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 Total of Code Count Percent Failures AFW 75 42.4% 2 — 1 2 1 — — — — — 6 27.3% HPCI 28 15.8% — 1 — — — — — — — — 1 4.5% MFW 43 24.3% 5 2 3 2 — 1 — — — — 13 59.1% RCIC 31 17.5% — 1 1 — — — — — — — 2 9.1% Total 177 100.0% 7 4 5 4 1 1 0 0 0 0 22 100.0% Note: a. FTR>1H is a failure mode for standby components (e.g., TDPs in AFW, HPCI, and RCIC systems), while FTR is a failure mode for normally running components (TDPs in MFW system). 6.2. Normally Running TDP Engineering Trends This section presents frequency trends for normally running TDP demands, run hours, and failure events. Figure 15 to Figure 18 provide the plots for frequency of normally running TDP start demands, run hours, FTS events, and FTR events: • Figure 15 shows the trend for normally running TDP frequency of start demands (demands per reactor year) • Figure 16 shows the trend for normally running TDP frequency of run hours (hours per reactor year) • Figure 17 shows the trend for normally running TDP frequency of FTS events (events per reactor year) 19 • Figure 18 shows the trend for normally running TDP frequency of FTR events (events per reactor year). The data for the above figures are provided in Section 8. The normally running system (MFW) from Table 2 is trended for each figure. In the lower left-hand corner of the trend figures, the regression p-values are reported along with the prior distribution used in the Bayesian update. A review of these p-values identified the following trend for normally running TDP for the most recent 10-year period: • Decreasing trend in the normally running TDP frequency of start demands (demands per reactor year) estimates, which is statistically significant with a p-value of 0.037 (see Figure 15). The same trend was observed in the 2022, 2020, and 2016 TDP update studies [2], [9], [10] as extremely or highly statistically significant. • Decreasing trend in the normally running TDP frequency of run hours (hours per reactor year) estimates, which is statistically significant with a p-value of 0.027 (see Figure 16). The same trend was observed in the 2022, 2020, and 2016 TDP update studies [2], [9], [10] as extremely or highly statistically significant. • Decreasing trend in the normally running TDP frequency of FTR events (events per reactor year) estimates, which is extremely statistically significant with a p-value of 0.0004 (see Figure 18). The same trend was observed in the 2022 TDP update study [2] as highly statistically significant. Figure 15. Frequency of start demands (demands per reactor year) trend for normally running TDPs. 20 Figure 16. Frequency of run hours (hours per reactor year) trend for normally running TDPs. Figure 17. Frequency of FTS events (events per reactor year) trend for normally running TDPs. 21 Figure 18. Frequency of FTR events (events per reactor year) trend for normally running TDPs. 6.3. Comparison of IRIS TDP Unplanned Demand Results with Industry Results An ongoing concern in the industry is whether a combination of test demand, non-test demand, and ESF demand data produces failure estimates that adequately predict standby component performance during unplanned demands (i.e., non-test and ESF demands). This comparison evaluates the same dataset for standby components used for the overall trends shown in this document but limits the failure data to those discovered during an ESF demand and the ESF demands reported in IRIS. The data are further limited to 2003 to present since the ESF demand reporting in IRIS is inconsistent prior to 2003. The standby TDP ESF unplanned demand data covering 2003 through 2024 are summarized in Table 7. Consistency between the unplanned demand data and the industry-average performance from 2020 Parameter Update (Table 2) was evaluated using the predictive distribution approach outlined in Sections 6.2.3.5 and 6.3.3.4 of NUREG/CR-6823, Handbook of Parameter Estimation for PRA [11]. The unplanned demand data were aggregated at the plant and system level (failures and demands). Assuming each plant and system can have a different failure probability, the industry-average distribution (from Table 2) was sampled for each plant and system. The predicted number of failure events for each plant and system was evaluated using the binomial distribution with the plant-specific failure probability and its associated number of demands. Then the total number of predicted failures was obtained by summing the individual plant results. This process was repeated 1,000 times, each time obtaining a total number of predicted failures. The 1,000 sample results were ordered from high to low. Then the actual number of unplanned demand failures observed (listed in the Observed Failures column of Table 7) was compared with this sample to determine the probability of observing this number of failures or greater. If the probability was greater than 0.05 and less than 0.95, then the unplanned demand performance is consistent with the industry-average distribution obtained from the IRIS data analysis. 22 Table 7. Standby TDP unplanned demand performance comparison with industry-average performance. Probability of Consistent with Demands or Observed Expected Failure Modes Plants ≥ Observed Industry-Average Hours Failures Failures Failures Performance? a FTS 99 900 4 4.8 0.49 Yes FTR≤1H 99 498 7 1.3 0.04 No FTR>1H 99 1400 1 8.9 0.75 Yes Note: a. If the probability of observing the actual failures or greater is ≥ 0.05 and ≤ 0.95, then the observed performance is considered to be consistent with the industry-average performance estimate. These consistency checks show that the FTS and FTR>1H failure observations in the unplanned demand data lie within their corresponding industry-average failure estimate distributions, provided in the 2020 Parameter Update (Table 2), that were based on both test and unplanned demands. However, the FTR≤1H failure observations are not consistent with the industry-average failure estimate distributions, and the TDP performs worse on a non-test or ESF demand than on a test demand. A review of the seven TDP ESF FTR≤1H failures showed that all events occurred between 2003 and 2008. This suggests that, if the consistency check were based on the most recent 15 years of data rather than the full 2003- 2024period, there would be zero failures over approximately 200-300 hours. This outcome would be consistent with the 2020 SPAR parameter update, which used 15-year data from 2006 to 2020. A quality assurance item has been created to revise the consistency check analysis by modifying the study period from the current 2003–study year range to the most recent 15 years. Once the code revision is completed, the 2024 TDP report can be updated with revised results. 6.4. TDP Engineering Analysis by Failure Modes The engineering analysis of the TDP failure breakdown by failure modes and other factors, such as subcomponents, failure causes, detection methods, and recovery possibility, are presented in this section. First, each analysis divides the events into two categories: standby and normally running TDPs. Note that the FTR≤1H failure mode only applies to standby TDPs and therefore only shows the standby category data. Then the events are further divided by the failure modes and factors, such as subcomponents, failure causes, detection methods, and recovery possibility. The failure modes are determined after IRIS data review by Idaho National Laboratory (INL) staff. See Section 7 for further description of failure modes. TDP subcomponent contributions to the three failure modes are presented in Figure 19. The subcomponent categories are similar to those used in the common-cause failure (CCF) database. The driver (specifically the governor) has the highest percentage contributions to failures for all the failure modes. TDP failure cause group contributions to the three failure modes are presented in Error! Reference source not found.. The cause groups are similar to those used in the CCF database. Table 8 shows the breakdown of the cause groups with the specific causes that were coded during the data collection. The most likely cause groups are Human, Design, and Component. The Human cause group is primarily influenced by maintenance and operating procedures and practices. The Component cause group includes the causes that were related to something internal to the component or an aging or worn-out part, which were categorized as the Internal cause group in 2016 and earlier previous studies. The Design cause group is influenced by manufacturing, installation, and design issues. 23 TDP failure detection methods for the three failure modes are presented in Figure 21. A failure can be detected during inspection, testing, post-maintenance testing (PMT), non-testing, or ESF demand. There are differences in the detection method based on the standby and normally running categories. • Standby: the most likely detection method for all three failure modes is test demand. Inspection is also important for the FTS and FTR failure modes. • Normally running: the most likely detection method for FTS and FTR is non-test demand. TDP recovery fractions for the three failure modes are presented in Figure 22. The overall non-recovery to recovery ratio is approximately 6:1, meaning that six of every seven failures were not recovered. Table 8. Component failure cause groups. Groupd Specific Cause Description Used when the cause of a failure is a non-specific result Internal to component, of a failure internal to the component that failed other piece-part than aging or wear. Component Used when the cause of a failure is the result of set point Set point drift drift or adjustment. Used when the cause of the failure is a non-specific Age/wear aging or wear issue. Used when a construction or installation error is made Construction/installation during the original or modification installation. This error or inadequacy includes specification of an incorrect component or material. Design Design error or inadequacy Used when a design error is made. Manufacturing error or Used when a manufacturing error is made during inadequacy component manufacture. Used when the cause of a failure is the result of an Ambient environmental environmental condition from the location of the stress component. The internal environment led to the failure. Internal environment Debris/foreign material as well as an operating medium Environment chemistry issue. Used when the cause of a failure is the result of an Extreme environmental environmental condition that places a higher-than- stress expected load on the equipment and is transitory in nature. Accidental action Used when a human error (during the performance of an (unintentional or undesired activity) results in an unintentional or undesired action. human errors) Human Used when the correct procedure is not followed, or the wrong procedure is followed (e.g., when a missed step or Human action procedure incorrect step in a surveillance procedure results in a component failure). d. The cause groups have been re-arranged in order to align with those currently used in the CCF database. 24 Groupd Specific Cause Description Used when a human error (during the performance of Inadequate maintenance maintenance) results in an unintentional or undesired action. Used when the cause of a failure is the result of an Inadequate procedure inadequate procedure operating or maintenance. Used when the cause of a failure is the result of a component state that is not associated with the State of other component component that failed. An example would be the diesel failed due to empty fuel storage tanks. Other Other (stated cause does Used when the cause of a failure is provided, but it does not fit other categories) not meet any one of the descriptions. Unknown Used when the cause of the failure is not known. 25 Figure 19. TDP failure event breakdown by subcomponent, failure mode, and operational status. 26 Figure 20. TDP failure event breakdown by cause group, failure mode, and operational status. 27 Figure 21. TDP failure event breakdown by failure detection method, failure mode, and operational status. 28 Figure 22. TDP failure event breakdown by recoverability determination, failure mode, and operational status. 29 7. TDP ASSEMBLY DESCRIPTION The TDP is generally comprised of a pump, a turbine driver, and a governor. Most plant designs use a single stage “Terry Turbine,” whose piece-parts include a turbine trip and throttle valve, a mechanical over speed trip mechanism, and a lubrication system. The various types of governors used for turbine speed control are mostly manufactured by the Woodward Corporation. For the AFW system TDP, the governors are predominantly mechanical/hydraulic, pressure-compensated, and have a pneumatic remote speed-setting capability. For the RCIC and HPCI systems, the TDPs typically have a Woodward-type EG-M electric/electronic governor and EGR hydraulic actuators. Piece-parts of all governors include a turbine stop valve and a governor valve, while the EG-M usually includes a ramp generator/signal converter and other electrical controls. The TDP failure modes include FTS, FTR≤1H, and FTR>1H for standby systems, FTS and FTR for normally running systems. These failure modes were used in NUREG/CR-6928 [8] and are similar to those used in the MSPI program. Guidelines for determining whether a component event reported in IRIS is to be included in FTS, FTR≤1H, or FTR>1H (FTR for normally running components) are similar to those used in the MSPI program. In general, any circumstance in which the component is not able to meet the performance requirements defined in the PRA is counted. This includes conditions revealed through testing, non- testing, ESF demands, or inspection. Run failures that occur beyond the typical 24-hour mission time in PRAs are included. However, certain events are excluded (e.g., events with slow starting times that do not exceed the PRA success criteria, events that are annunciated immediately in the control room without a demand, and run events that are shown to not have caused an actual run failure within 24 hours). Events occurring during maintenance or PMT that are related to the actual maintenance activities are excluded. All TDP events within IRIS were reviewed to ensure that they were binned to the correct failure mode— FTS, FTR≤1H, FTR>1H (or FTR), or no failure. However, even given detailed descriptions of failure events, this binning still required some judgment and involves some uncertainty. Guidelines for counting demands and run hours are similar to those in the MSPI program. Start and run demands include those resulting from tests, non-test demands, and ESF demands. Demands during maintenance and post-maintenance are excluded. Similarly, run hours include those from tests, non-test demands, and ESF demands, but exclude those during maintenance and post-maintenance. 30 8. DATA TABLES In this section, the plot data for Figure 1 to Figure 18 in previous sections are provided in Table 9 to Table 26, respectively. Figure Table Analysis Figure 1 Table 9 Failure probability estimate trend for standby TDP FTS Figure 2 Table 10 Failure probability estimate trend for standby TDP FTR≤1H Figure 3 Table 11 Failure rate estimate trend for standby TDP FTR>1H Figure 4 Table 12 Failure probability estimate trend for normally running TDP FTS Figure 5 Table 13 Failure rate estimate trend for normally running TDP FTR Figure 6 Table 14 Pooled standby TDP UA trend Figure 7 Table 15 Standby TDP total unreliability trend (24-hour mission) Figure 8 Table 16 Normally running TDP total unreliability trend (24-hour mission) Frequency of start demands (demands per reactor year) trend for standby Figure 9 Table 17 TDPs Figure 10 Table 18 Frequency of run ≤ 1H hours (hours per reactor year) trend for standby TDPs Figure 11 Table 19 Frequency of run > 1H hours (hours per reactor year) trend for standby TDPs Figure 12 Table 20 Frequency of FTS events (events per reactor year) trend for standby TDPs Figure 13 Table 21 Frequency of FTR≤1H events (events per reactor year) trend for standby TDPs Frequency of FTR>1H events (events per reactor year) trend for standby Figure 14 Table 22 TDPs Frequency of start demands (demands per reactor year) trend for normally Figure 15 Table 23 running TDPs Frequency of run hours (hours per reactor year) trend for normally running Figure 16 Table 24 TDPs Frequency of FTS events (events per reactor year) trend for normally running Figure 17 Table 25 TDPs Frequency of FTR events (events per reactor year) trend for normally running Figure 18 Table 26 TDPs 31 Table 9. Plot data for Figure 1, failure probability estimate trend for standby TDP FTS. Year Failures Demands Lower Upper Lower Upper Mean Mean (5%) (95%) (5%) (95%) SPAR 2020 — — — 4.59E-04 1.47E-02 5.32E-03 1998 2 1,599 — — — 3.34E-04 3.24E-03 1.46E-03 1999 12 1,511 — — — 4.49E-03 1.15E-02 7.68E-03 2000 12 1,443 — — — 4.69E-03 1.20E-02 8.01E-03 2001 5 1,441 — — — 1.47E-03 6.33E-03 3.54E-03 2002 4 1,414 — — — 1.09E-03 5.54E-03 2.95E-03 2003 8 1,539 — — — 2.63E-03 8.34E-03 5.14E-03 2004 10 1,484 — — — 3.63E-03 1.02E-02 6.57E-03 2005 6 1,462 — — — 1.87E-03 7.10E-03 4.13E-03 2006 9 1,500 — — — 3.14E-03 9.32E-03 5.88E-03 2007 7 1,421 — — — 2.37E-03 8.14E-03 4.89E-03 2008 12 1,467 — — — 4.62E-03 1.19E-02 7.89E-03 2009 12 1,547 — — — 4.40E-03 1.13E-02 7.51E-03 2010 9 1,578 — — — 2.99E-03 8.90E-03 5.61E-03 2011 9 1,576 — — — 3.00E-03 8.91E-03 5.62E-03 2012 6 1,519 — — — 1.81E-03 6.85E-03 3.98E-03 2013 8 1,556 — — — 2.60E-03 8.25E-03 5.09E-03 2014 12 1,507 — — — 4.51E-03 1.16E-02 7.70E-03 2015 3 1,528 3.81E-03 1.98E-03 7.32E-03 6.61E-04 4.29E-03 2.14E-03 2016 9 1,508 3.57E-03 2.05E-03 6.18E-03 3.12E-03 9.28E-03 5.86E-03 2017 7 1,502 3.34E-03 2.10E-03 5.31E-03 2.25E-03 7.73E-03 4.64E-03 2018 4 1,489 3.12E-03 2.09E-03 4.68E-03 1.04E-03 5.29E-03 2.81E-03 2019 8 1,448 2.93E-03 2.00E-03 4.29E-03 2.78E-03 8.82E-03 5.44E-03 2020 2 1,421 2.74E-03 1.82E-03 4.11E-03 3.73E-04 3.62E-03 1.63E-03 2021 4 1,416 2.56E-03 1.60E-03 4.10E-03 1.09E-03 5.54E-03 2.95E-03 2022 2 1,382 2.40E-03 1.37E-03 4.19E-03 3.83E-04 3.71E-03 1.67E-03 2023 5 1,387 2.25E-03 1.16E-03 4.36E-03 1.53E-03 6.56E-03 3.67E-03 2024 2 1,418 2.10E-03 9.68E-04 4.57E-03 3.74E-04 3.62E-03 1.64E-03 Total 189 40,063 32 Table 10. Plot data for Figure 2, failure probability estimate trend for standby TDP FTR≤1H. Year Failures Demands Lower Upper Lower Upper Mean Mean (5%) (95%) (5%) (95%) SPAR 2020 — — — 5.17E-06 1.03E-02 2.56E-03 1998 2 1,599 — — — 3.10E-04 3.00E-03 1.35E-03 1999 3 1,511 — — — 6.16E-04 4.00E-03 1.99E-03 2000 10 1,443 — — — 3.43E-03 9.65E-03 6.21E-03 2001 4 1,441 — — — 9.84E-04 5.01E-03 2.66E-03 2002 5 1,414 — — — 1.38E-03 5.92E-03 3.31E-03 2003 8 1,539 — — — 2.43E-03 7.72E-03 4.75E-03 2004 0 1,484 — — — 1.13E-06 1.11E-03 2.89E-04 2005 4 1,462 — — — 9.72E-04 4.94E-03 2.63E-03 2006 2 1,500 — — — 3.27E-04 3.16E-03 1.43E-03 2007 7 1,421 — — — 2.17E-03 7.48E-03 4.49E-03 2008 4 1,467 — — — 9.69E-04 4.93E-03 2.62E-03 2009 5 1,547 — — — 1.27E-03 5.48E-03 3.06E-03 2010 3 1,578 — — — 5.93E-04 3.85E-03 1.92E-03 2011 4 1,576 — — — 9.11E-04 4.64E-03 2.47E-03 2012 1 1,519 — — — 9.95E-05 2.21E-03 8.48E-04 2013 0 1,556 — — — 1.09E-06 1.06E-03 2.77E-04 2014 1 1,507 — — — 1.00E-04 2.23E-03 8.54E-04 2015 4 1,528 1.34E-03 3.83E-04 4.69E-03 9.36E-04 4.76E-03 2.53E-03 2016 4 1,508 1.22E-03 4.23E-04 3.51E-03 9.46E-04 4.82E-03 2.56E-03 2017 0 1,502 1.11E-03 4.54E-04 2.70E-03 1.12E-06 1.10E-03 2.86E-04 2018 3 1,489 1.01E-03 4.66E-04 2.17E-03 6.24E-04 4.05E-03 2.01E-03 2019 0 1,448 9.15E-04 4.46E-04 1.88E-03 1.16E-06 1.13E-03 2.95E-04 2020 1 1,421 8.32E-04 3.92E-04 1.76E-03 1.05E-04 2.34E-03 8.98E-04 2021 2 1,416 7.56E-04 3.21E-04 1.78E-03 3.44E-04 3.32E-03 1.50E-03 2022 1 1,382 6.87E-04 2.49E-04 1.90E-03 1.08E-04 2.40E-03 9.20E-04 2023 0 1,387 6.25E-04 1.87E-04 2.09E-03 1.20E-06 1.17E-03 3.06E-04 2024 2 1,418 5.68E-04 1.38E-04 2.34E-03 3.44E-04 3.32E-03 1.50E-03 Total 80 40,063 33 Table 11. Plot data for Figure 3, failure rate estimate trend for standby TDP FTR>1H. Regression Curve Data Points Yearly Estimate Data Points Year Failures Hours Lower Upper Lower Upper Mean Mean (5%) (95%) (5%) (95%) SPAR 2020 — — — 1.23E-05 2.55E-02 6.35E-03 1998 0 2,126 — — — 8.60E-07 8.40E-04 2.19E-04 1999 1 1,097 — — — 1.40E-04 3.11E-03 1.19E-03 2000 3 510 — — — 1.62E-03 1.05E-02 5.22E-03 2001 1 653 — — — 2.16E-04 4.80E-03 1.84E-03 2002 0 1,174 — — — 1.47E-06 1.44E-03 3.75E-04 2003 1 1,500 — — — 1.06E-04 2.35E-03 9.04E-04 2004 4 366 — — — 3.16E-03 1.61E-02 8.55E-03 2005 3 240 — — — 2.70E-03 1.76E-02 8.74E-03 2006 0 240 — — — 4.91E-06 4.80E-03 1.25E-03 2007 1 254 — — — 4.25E-04 9.43E-03 3.62E-03 2008 2 279 — — — 1.30E-03 1.26E-02 5.69E-03 2009 0 230 — — — 5.03E-06 4.92E-03 1.28E-03 2010 1 318 — — — 3.68E-04 8.16E-03 3.13E-03 2011 4 416 — — — 2.89E-03 1.47E-02 7.81E-03 2012 4 298 — — — 3.63E-03 1.84E-02 9.81E-03 2013 3 329 — — — 2.22E-03 1.44E-02 7.16E-03 2014 3 314 — — — 2.28E-03 1.48E-02 7.38E-03 2015 2 283 6.91E-03 4.20E-03 1.14E-02 1.29E-03 1.25E-02 5.64E-03 2016 2 366 5.58E-03 3.66E-03 8.53E-03 1.09E-03 1.05E-02 4.75E-03 2017 2 327 4.51E-03 3.15E-03 6.45E-03 1.18E-03 1.14E-02 5.13E-03 2018 2 220 3.64E-03 2.66E-03 4.97E-03 1.51E-03 1.46E-02 6.57E-03 2019 1 218 2.94E-03 2.19E-03 3.94E-03 4.65E-04 1.03E-02 3.96E-03 2020 0 266 2.37E-03 1.75E-03 3.22E-03 4.61E-06 4.50E-03 1.17E-03 2021 0 220 1.91E-03 1.35E-03 2.71E-03 5.18E-06 5.06E-03 1.32E-03 2022 0 250 1.55E-03 1.03E-03 2.33E-03 4.79E-06 4.68E-03 1.22E-03 2023 0 221 1.25E-03 7.71E-04 2.02E-03 5.16E-06 5.04E-03 1.31E-03 2024 0 273 1.01E-03 5.74E-04 1.77E-03 4.54E-06 4.44E-03 1.15E-03 Total 40 12,987 34 Table 12. Plot data for Figure 4, failure probability estimate trend for normally running TDP FTS. Year Failures Demands Lower Upper Lower Upper Mean Mean (5%) (95%) (5%) (95%) SPAR 2020 — — — 5.45E-05 1.62E-02 4.60E-03 1998 2 79 — — — 3.83E-03 3.66E-02 1.66E-02 1999 2 79 — — — 3.83E-03 3.66E-02 1.66E-02 2000 0 79 — — — 1.17E-05 1.28E-02 3.31E-03 2001 1 78 — — — 1.17E-03 2.61E-02 1.01E-02 2002 0 78 — — — 1.17E-05 1.29E-02 3.33E-03 2003 0 78 — — — 1.17E-05 1.29E-02 3.33E-03 2004 0 78 — — — 1.17E-05 1.29E-02 3.33E-03 2005 3 78 — — — 7.26E-03 4.64E-02 2.32E-02 2006 1 78 — — — 1.17E-03 2.61E-02 1.00E-02 2007 0 78 — — — 1.17E-05 1.28E-02 3.32E-03 2008 0 78 — — — 1.17E-05 1.28E-02 3.32E-03 2009 1 78 — — — 1.18E-03 2.62E-02 1.01E-02 2010 0 76 — — — 1.19E-05 1.30E-02 3.37E-03 2011 0 76 — — — 1.19E-05 1.30E-02 3.37E-03 2012 1 76 — — — 1.19E-03 2.65E-02 1.02E-02 2013 1 76 — — — 1.19E-03 2.65E-02 1.02E-02 2014 0 76 — — — 1.19E-05 1.30E-02 3.37E-03 2015 0 75 3.43E-03 1.69E-03 6.97E-03 1.19E-05 1.31E-02 3.39E-03 2016 1 72 3.30E-03 1.80E-03 6.02E-03 1.22E-03 2.72E-02 1.05E-02 2017 0 72 3.17E-03 1.91E-03 5.26E-03 1.22E-05 1.34E-02 3.47E-03 2018 0 72 3.04E-03 1.98E-03 4.67E-03 1.22E-05 1.34E-02 3.47E-03 2019 0 72 2.92E-03 1.99E-03 4.28E-03 1.22E-05 1.34E-02 3.47E-03 2020 1 72 2.80E-03 1.92E-03 4.08E-03 1.22E-03 2.72E-02 1.05E-02 2021 0 72 2.69E-03 1.78E-03 4.07E-03 1.22E-05 1.34E-02 3.47E-03 2022 0 72 2.59E-03 1.59E-03 4.19E-03 1.22E-05 1.34E-02 3.47E-03 2023 0 72 2.48E-03 1.40E-03 4.41E-03 1.22E-05 1.34E-02 3.47E-03 2024 0 72 2.38E-03 1.21E-03 4.70E-03 1.22E-05 1.34E-02 3.47E-03 Total 14 2,044 35 Table 13. Plot data for Figure 5, failure rate estimate trend for normally running TDP FTR. Regression Curve Data Points Yearly Estimate Data Points Year Failures Hours Lower Upper Lower Upper Mean Mean (5%) (95%) (5%) (95%) SPAR 2020 — — — 2.53E-07 2.71E-05 8.45E-06 1998 1 335,022 — — — 4.47E-07 9.92E-06 3.81E-06 1999 6 335,022 — — — 7.48E-06 2.84E-05 1.65E-05 2000 2 335,022 — — — 1.45E-06 1.41E-05 6.35E-06 2001 3 335,417 — — — 2.75E-06 1.78E-05 8.88E-06 2002 3 335,311 — — — 2.75E-06 1.78E-05 8.88E-06 2003 6 335,387 — — — 7.47E-06 2.84E-05 1.65E-05 2004 3 335,356 — — — 2.75E-06 1.78E-05 8.88E-06 2005 6 335,371 — — — 7.47E-06 2.84E-05 1.65E-05 2006 3 335,356 — — — 2.75E-06 1.78E-05 8.88E-06 2007 3 335,387 — — — 2.75E-06 1.78E-05 8.88E-06 2008 3 335,432 — — — 2.75E-06 1.78E-05 8.88E-06 2009 3 333,290 — — — 2.76E-06 1.79E-05 8.93E-06 2010 6 327,196 — — — 7.63E-06 2.90E-05 1.68E-05 2011 2 327,105 — — — 1.48E-06 1.43E-05 6.48E-06 2012 6 327,181 — — — 7.63E-06 2.90E-05 1.68E-05 2013 4 327,166 — — — 4.31E-06 2.19E-05 1.17E-05 2014 2 327,135 — — — 1.48E-06 1.43E-05 6.48E-06 2015 5 326,131 1.00E-05 5.49E-06 1.82E-05 5.94E-06 2.56E-05 1.43E-05 2016 2 321,356 7.51E-06 4.52E-06 1.25E-05 1.51E-06 1.46E-05 6.58E-06 2017 3 321,325 5.64E-06 3.66E-06 8.70E-06 2.85E-06 1.85E-05 9.21E-06 2018 2 321,280 4.23E-06 2.89E-06 6.21E-06 1.51E-06 1.46E-05 6.58E-06 2019 0 321,386 3.18E-06 2.19E-06 4.60E-06 5.17E-09 5.05E-06 1.32E-06 2020 1 321,325 2.39E-06 1.60E-06 3.55E-06 4.63E-07 1.03E-05 3.95E-06 2021 0 321,386 1.79E-06 1.13E-06 2.83E-06 5.17E-09 5.05E-06 1.32E-06 2022 0 321,447 1.34E-06 7.84E-07 2.30E-06 5.17E-09 5.05E-06 1.32E-06 2023 0 321,325 1.01E-06 5.35E-07 1.90E-06 5.17E-09 5.05E-06 1.32E-06 2024 0 321,280 7.58E-07 3.62E-07 1.59E-06 5.17E-09 5.05E-06 1.32E-06 Total 75 8,875,397 36 Table 14. Plot data for Figure 6, pooled standby TDP UA trend. Regression Curve Data Points Yearly Estimate Data Points Year UA Hours Critical Hours Lower Upper Lower Upper Mean Mean (5%) (95%) (5%) (95%) SPAR 2020 — — — 1.16E-05 1.46E-02 7.30E-03 1998 8,303 866,019 — — — 1.06E-04 3.54E-02 9.96E-03 1999 8,368 932,827 — — — 6.85E-04 2.55E-02 9.06E-03 2000 7,172 953,904 — — — 8.55E-04 2.05E-02 7.77E-03 2001 7,895 960,556 — — — 3.67E-04 2.56E-02 8.39E-03 2002 7,870 962,744 — — — 5.37E-04 2.36E-02 8.19E-03 2003 8,371 939,190 — — — 8.62E-04 2.42E-02 8.97E-03 2004 7,232 972,701 — — — 5.32E-04 2.17E-02 7.62E-03 2005 6,152 962,533 — — — 8.19E-04 1.66E-02 6.50E-03 2006 6,545 965,329 — — — 9.07E-04 1.71E-02 6.78E-03 2007 7,838 976,725 — — — 4.91E-05 3.07E-02 8.26E-03 2008 7,332 971,612 — — — 5.97E-05 2.74E-02 7.53E-03 2009 7,832 954,932 — — — 2.41E-05 3.26E-02 8.33E-03 2010 8,167 964,327 — — — 8.02E-04 2.29E-02 8.46E-03 2011 8,041 937,926 — — — 5.32E-04 2.58E-02 8.84E-03 2012 7,352 921,716 — — — 4.34E-04 2.26E-02 7.68E-03 2013 8,161 927,540 — — — 1.85E-08 4.32E-02 8.48E-03 2014 7,050 938,778 — — — 4.90E-04 2.20E-02 7.61E-03 2015 6,365 924,172 6.93E-03 5.87E-03 7.98E-03 7.69E-04 1.80E-02 6.88E-03 2016 7,131 932,914 6.77E-03 5.94E-03 7.59E-03 6.79E-04 2.10E-02 7.66E-03 2017 6,750 926,540 6.60E-03 6.02E-03 7.19E-03 4.12E-04 2.15E-02 7.30E-03 2018 5,280 920,288 6.44E-03 6.09E-03 6.79E-03 2.77E-04 1.76E-02 5.81E-03 2019 5,371 916,107 6.28E-03 6.16E-03 6.40E-03 4.24E-04 1.70E-02 5.97E-03 2020 4,264 890,347 6.12E-03 6.00E-03 6.24E-03 2.19E-04 1.49E-02 4.89E-03 2021 4,832 872,242 5.96E-03 5.61E-03 6.31E-03 3.27E-04 1.64E-02 5.60E-03 2022 4,444 860,755 5.80E-03 5.21E-03 6.38E-03 3.42E-05 1.94E-02 5.24E-03 2023 5,515 862,112 5.64E-03 4.82E-03 6.46E-03 1.26E-04 2.17E-02 6.46E-03 2024 5,283 856,426 5.47E-03 4.42E-03 6.53E-03 9.96E-05 2.12E-02 6.19E-03 Total 184,918 25,071,261 37 Table 15. Plot data for Figure 7, standby TDP total unreliability trend (24-hour mission). Regression Curve Data Points Yearly Estimate Data Points Year Lower Upper Lower Mean Upper (95%) Mean (5%) (95%) (5%) 1998 — — — 3.48E-03 4.55E-02 1.75E-02 1999 — — — 1.70E-02 8.38E-02 4.36E-02 2000 — — — 5.54E-02 2.33E-01 1.31E-01 2001 — — — 1.64E-02 1.22E-01 5.68E-02 2002 — — — 7.54E-03 5.25E-02 2.34E-02 2003 — — — 1.70E-02 7.26E-02 3.84E-02 2004 — — — 7.98E-02 3.15E-01 1.85E-01 2005 — — — 7.42E-02 3.44E-01 1.88E-01 2006 — — — 1.01E-02 1.17E-01 4.09E-02 2007 — — — 2.33E-02 2.12E-01 9.40E-02 2008 — — — 4.47E-02 2.72E-01 1.36E-01 2009 — — — 1.22E-02 1.26E-01 4.60E-02 2010 — — — 2.28E-02 1.90E-01 8.41E-02 2011 — — — 7.38E-02 2.90E-01 1.72E-01 2012 — — — 9.15E-02 3.48E-01 2.07E-01 2013 — — — 6.00E-02 2.85E-01 1.59E-01 2014 — — — 6.72E-02 3.05E-01 1.66E-01 2015 1.51E-01 9.88E-02 2.30E-01 4.05E-02 2.63E-01 1.32E-01 2016 1.25E-01 8.75E-02 1.79E-01 4.15E-02 2.22E-01 1.15E-01 2017 1.04E-01 7.70E-02 1.41E-01 3.76E-02 2.47E-01 1.18E-01 2018 8.64E-02 6.69E-02 1.12E-01 4.61E-02 2.81E-01 1.42E-01 2019 7.18E-02 5.70E-02 9.04E-02 2.01E-02 2.23E-01 9.51E-02 2020 5.96E-02 4.73E-02 7.51E-02 4.19E-03 1.01E-01 3.29E-02 2021 4.95E-02 3.83E-02 6.40E-02 6.24E-03 1.16E-01 3.77E-02 2022 4.11E-02 3.04E-02 5.56E-02 4.24E-03 1.12E-01 3.40E-02 2023 3.42E-02 2.39E-02 4.89E-02 5.86E-03 1.21E-01 4.02E-02 2024 2.84E-02 1.86E-02 4.33E-02 4.37E-03 1.12E-01 3.48E-02 38 Table 16. Plot data for Figure 8, normally running TDP total unreliability trend (24-hour mission). Regression Curve Data Points Yearly Estimate Data Points Year Lower Upper Lower Upper Mean Mean (5%) (95%) (5%) (95%) 1998 — — — 3.96E-03 3.81E-02 1.71E-02 1999 — — — 4.29E-03 3.50E-02 1.67E-02 2000 — — — 1.36E-04 1.41E-02 3.69E-03 2001 — — — 1.41E-03 2.78E-02 1.06E-02 2002 — — — 2.06E-04 1.30E-02 3.55E-03 2003 — — — 3.28E-04 1.44E-02 3.88E-03 2004 — — — 1.84E-04 1.27E-02 3.42E-03 2005 — — — 7.29E-03 4.66E-02 2.34E-02 2006 — — — 1.35E-03 2.56E-02 9.84E-03 2007 — — — 1.68E-04 1.31E-02 3.42E-03 2008 — — — 1.70E-04 1.50E-02 4.02E-03 2009 — — — 1.35E-03 2.75E-02 1.02E-02 2010 — — — 3.33E-04 1.27E-02 3.67E-03 2011 — — — 1.39E-04 1.24E-02 3.27E-03 2012 — — — 1.51E-03 2.60E-02 1.03E-02 2013 — — — 1.39E-03 2.62E-02 1.04E-02 2014 — — — 1.36E-04 1.24E-02 3.35E-03 2015 5.35E-03 2.93E-03 9.78E-03 2.83E-04 1.33E-02 3.60E-03 2016 5.10E-03 3.06E-03 8.51E-03 1.46E-03 2.64E-02 1.05E-02 2017 4.86E-03 3.16E-03 7.48E-03 1.90E-04 1.20E-02 3.48E-03 2018 4.64E-03 3.22E-03 6.69E-03 1.49E-04 1.39E-02 3.61E-03 2019 4.42E-03 3.18E-03 6.15E-03 2.90E-05 1.25E-02 3.28E-03 2020 4.22E-03 3.03E-03 5.86E-03 1.24E-03 2.72E-02 1.06E-02 2021 4.02E-03 2.79E-03 5.80E-03 4.94E-05 1.34E-02 3.58E-03 2022 3.83E-03 2.49E-03 5.89E-03 2.47E-05 1.36E-02 3.63E-03 2023 3.65E-03 2.19E-03 6.09E-03 3.21E-05 1.36E-02 3.38E-03 2024 3.48E-03 1.91E-03 6.37E-03 3.03E-05 1.17E-02 3.11E-03 39 Table 17. Plot data for Figure 9, frequency of start demands (demands per reactor year) trend for standby TDPs. Reactor Year Demands Lower Upper Upper Years Mean Lower (5%) Mean (5%) (95%) (95%) 1998 1,599 97.0 — — — 1.58E+01 1.72E+01 1.65E+01 1999 1,511 97.0 — — — 1.49E+01 1.63E+01 1.56E+01 2000 1,443 97.3 — — — 1.42E+01 1.55E+01 1.48E+01 2001 1,441 97.0 — — — 1.42E+01 1.55E+01 1.49E+01 2002 1,414 97.0 — — — 1.39E+01 1.52E+01 1.46E+01 2003 1,539 97.0 — — — 1.52E+01 1.65E+01 1.59E+01 2004 1,484 97.3 — — — 1.46E+01 1.59E+01 1.53E+01 2005 1,462 97.0 — — — 1.44E+01 1.57E+01 1.51E+01 2006 1,500 97.0 — — — 1.48E+01 1.61E+01 1.55E+01 2007 1,421 97.6 — — — 1.39E+01 1.52E+01 1.46E+01 2008 1,467 98.3 — — — 1.43E+01 1.56E+01 1.49E+01 2009 1,547 98.0 — — — 1.51E+01 1.65E+01 1.58E+01 2010 1,578 98.0 — — — 1.54E+01 1.68E+01 1.61E+01 2011 1,576 98.0 — — — 1.54E+01 1.68E+01 1.61E+01 2012 1,519 98.3 — — — 1.48E+01 1.61E+01 1.55E+01 2013 1,556 95.6 — — — 1.56E+01 1.70E+01 1.63E+01 2014 1,507 94.0 — — — 1.54E+01 1.67E+01 1.60E+01 2015 1,528 93.0 1.62E+01 1.58E+01 1.65E+01 1.57E+01 1.71E+01 1.64E+01 2016 1,508 93.2 1.61E+01 1.59E+01 1.64E+01 1.55E+01 1.69E+01 1.62E+01 2017 1,502 93.0 1.61E+01 1.59E+01 1.63E+01 1.55E+01 1.69E+01 1.61E+01 2018 1,489 93.0 1.61E+01 1.59E+01 1.63E+01 1.53E+01 1.67E+01 1.60E+01 2019 1,448 92.0 1.60E+01 1.59E+01 1.62E+01 1.51E+01 1.64E+01 1.57E+01 2020 1,421 90.2 1.60E+01 1.58E+01 1.62E+01 1.51E+01 1.64E+01 1.57E+01 2021 1,416 88.3 1.60E+01 1.58E+01 1.62E+01 1.53E+01 1.68E+01 1.60E+01 2022 1,382 87.4 1.59E+01 1.57E+01 1.62E+01 1.51E+01 1.65E+01 1.58E+01 2023 1,387 87.0 1.59E+01 1.56E+01 1.62E+01 1.52E+01 1.67E+01 1.59E+01 2024 1,418 87.2 1.59E+01 1.56E+01 1.62E+01 1.55E+01 1.70E+01 1.62E+01 Total 40,063 2,555.7 40 Table 18. Plot data for Figure 10, frequency of run ≤ 1H hours (hours per reactor year) trend for standby TDPs. Reactor Year Hours Upper Upper Years Mean Lower (5%) Lower (5%) Mean (95%) (95%) 1998 1,599 97.0 — — — 1.58E+01 1.72E+01 1.65E+01 1999 1,511 97.0 — — — 1.49E+01 1.63E+01 1.56E+01 2000 1,443 97.3 — — — 1.42E+01 1.55E+01 1.48E+01 2001 1,441 97.0 — — — 1.42E+01 1.55E+01 1.49E+01 2002 1,414 97.0 — — — 1.39E+01 1.52E+01 1.46E+01 2003 1,539 97.0 — — — 1.52E+01 1.65E+01 1.59E+01 2004 1,484 97.3 — — — 1.46E+01 1.59E+01 1.53E+01 2005 1,462 97.0 — — — 1.44E+01 1.57E+01 1.51E+01 2006 1,500 97.0 — — — 1.48E+01 1.61E+01 1.55E+01 2007 1,421 97.6 — — — 1.39E+01 1.52E+01 1.46E+01 2008 1,467 98.3 — — — 1.43E+01 1.56E+01 1.49E+01 2009 1,547 98.0 — — — 1.51E+01 1.65E+01 1.58E+01 2010 1,578 98.0 — — — 1.54E+01 1.68E+01 1.61E+01 2011 1,576 98.0 — — — 1.54E+01 1.68E+01 1.61E+01 2012 1,519 98.3 — — — 1.48E+01 1.61E+01 1.55E+01 2013 1,556 95.6 — — — 1.56E+01 1.70E+01 1.63E+01 2014 1,507 94.0 — — — 1.54E+01 1.67E+01 1.60E+01 2015 1,528 93.0 1.62E+01 1.58E+01 1.65E+01 1.57E+01 1.71E+01 1.64E+01 2016 1,508 93.2 1.61E+01 1.59E+01 1.64E+01 1.55E+01 1.69E+01 1.62E+01 2017 1,502 93.0 1.61E+01 1.59E+01 1.63E+01 1.55E+01 1.69E+01 1.61E+01 2018 1,489 93.0 1.61E+01 1.59E+01 1.63E+01 1.53E+01 1.67E+01 1.60E+01 2019 1,448 92.0 1.60E+01 1.59E+01 1.62E+01 1.51E+01 1.64E+01 1.57E+01 2020 1,421 90.2 1.60E+01 1.58E+01 1.62E+01 1.51E+01 1.64E+01 1.57E+01 2021 1,416 88.3 1.60E+01 1.58E+01 1.62E+01 1.53E+01 1.68E+01 1.60E+01 2022 1,382 87.4 1.59E+01 1.57E+01 1.62E+01 1.51E+01 1.65E+01 1.58E+01 2023 1,387 87.0 1.59E+01 1.56E+01 1.62E+01 1.52E+01 1.67E+01 1.59E+01 2024 1,418 87.2 1.59E+01 1.56E+01 1.62E+01 1.55E+01 1.70E+01 1.62E+01 Total 40,063 2,555.7 41 Table 19. Plot data for Figure 11, frequency of run > 1H hours (hours per reactor year) trend for standby TDPs. Reactor Year Run Hours Lower Upper Lower Upper Years Mean Mean (5%) (95%) (5%) (95%) 1998 2,126 97.0 — — — 2.11E+01 2.27E+01 2.19E+01 1999 1,097 97.0 — — — 1.07E+01 1.19E+01 1.13E+01 2000 510 97.3 — — — 4.86E+00 5.64E+00 5.24E+00 2001 653 97.0 — — — 6.30E+00 7.18E+00 6.73E+00 2002 1,174 97.0 — — — 1.15E+01 1.27E+01 1.21E+01 2003 1,500 97.0 — — — 1.48E+01 1.61E+01 1.54E+01 2004 366 97.3 — — — 3.44E+00 4.10E+00 3.76E+00 2005 240 97.0 — — — 2.22E+00 2.76E+00 2.48E+00 2006 240 97.0 — — — 2.22E+00 2.75E+00 2.47E+00 2007 254 97.6 — — — 2.34E+00 2.89E+00 2.60E+00 2008 279 98.3 — — — 2.56E+00 3.13E+00 2.84E+00 2009 230 98.0 — — — 2.10E+00 2.62E+00 2.35E+00 2010 318 98.0 — — — 2.95E+00 3.56E+00 3.25E+00 2011 416 98.0 — — — 3.90E+00 4.60E+00 4.24E+00 2012 298 98.3 — — — 2.75E+00 3.34E+00 3.03E+00 2013 329 95.6 — — — 3.13E+00 3.77E+00 3.44E+00 2014 314 94.0 — — — 3.04E+00 3.67E+00 3.34E+00 2015 283 93.0 3.19E+00 2.52E+00 4.05E+00 2.75E+00 3.36E+00 3.05E+00 2016 366 93.2 3.12E+00 2.55E+00 3.81E+00 3.59E+00 4.28E+00 3.92E+00 2017 327 93.0 3.05E+00 2.57E+00 3.61E+00 3.20E+00 3.85E+00 3.51E+00 2018 220 93.0 2.98E+00 2.58E+00 3.44E+00 2.11E+00 2.65E+00 2.37E+00 2019 218 92.0 2.91E+00 2.55E+00 3.33E+00 2.12E+00 2.66E+00 2.37E+00 2020 266 90.2 2.84E+00 2.48E+00 3.27E+00 2.66E+00 3.26E+00 2.95E+00 2021 220 88.3 2.78E+00 2.38E+00 3.25E+00 2.22E+00 2.78E+00 2.49E+00 2022 250 87.4 2.72E+00 2.26E+00 3.27E+00 2.57E+00 3.18E+00 2.86E+00 2023 221 87.0 2.66E+00 2.13E+00 3.31E+00 2.26E+00 2.84E+00 2.54E+00 2024 273 87.2 2.59E+00 2.00E+00 3.36E+00 2.82E+00 3.45E+00 3.12E+00 Total 12,987 2,555.7 42 Table 20. Plot data for Figure 12, frequency of FTS events (events per reactor year) trend for standby TDPs. Reactor Year Failures Lower Upper Lower Upper Years Mean Mean (5%) (95%) (5%) (95%) 1998 2 97.0 — — — 5.37E-03 6.59E-02 2.34E-02 1999 12 97.0 — — — 6.85E-02 1.88E-01 1.17E-01 2000 12 97.3 — — — 6.83E-02 1.87E-01 1.17E-01 2001 5 97.0 — — — 2.14E-02 1.05E-01 5.15E-02 2002 4 97.0 — — — 1.56E-02 9.22E-02 4.22E-02 2003 8 97.0 — — — 4.06E-02 1.41E-01 7.96E-02 2004 10 97.3 — — — 5.42E-02 1.64E-01 9.81E-02 2005 6 97.0 — — — 2.76E-02 1.17E-01 6.09E-02 2006 9 97.0 — — — 4.74E-02 1.53E-01 8.90E-02 2007 7 97.6 — — — 3.38E-02 1.29E-01 6.99E-02 2008 12 98.3 — — — 6.77E-02 1.86E-01 1.16E-01 2009 12 98.0 — — — 6.78E-02 1.86E-01 1.16E-01 2010 9 98.0 — — — 4.70E-02 1.52E-01 8.82E-02 2011 9 98.0 — — — 4.70E-02 1.52E-01 8.82E-02 2012 6 98.3 — — — 2.73E-02 1.16E-01 6.02E-02 2013 8 95.6 — — — 4.12E-02 1.43E-01 8.07E-02 2014 12 94.0 — — — 7.04E-02 1.93E-01 1.21E-01 2015 3 93.0 6.19E-02 3.21E-02 1.19E-01 1.05E-02 8.23E-02 3.41E-02 2016 9 93.2 5.78E-02 3.32E-02 1.00E-01 4.91E-02 1.59E-01 9.23E-02 2017 7 93.0 5.39E-02 3.39E-02 8.58E-02 3.53E-02 1.34E-01 7.30E-02 2018 4 93.0 5.03E-02 3.36E-02 7.53E-02 1.62E-02 9.58E-02 4.38E-02 2019 8 92.0 4.70E-02 3.21E-02 6.87E-02 4.26E-02 1.48E-01 8.36E-02 2020 2 90.2 4.39E-02 2.93E-02 6.56E-02 5.73E-03 7.04E-02 2.50E-02 2021 4 88.3 4.09E-02 2.57E-02 6.52E-02 1.70E-02 1.00E-01 4.59E-02 2022 2 87.4 3.82E-02 2.20E-02 6.64E-02 5.90E-03 7.24E-02 2.57E-02 2023 5 87.0 3.57E-02 1.85E-02 6.87E-02 2.36E-02 1.16E-01 5.69E-02 2024 2 87.2 3.33E-02 1.54E-02 7.18E-02 5.91E-03 7.25E-02 2.58E-02 Total 189 2,555.7 43 Table 21. Plot data for Figure 13, frequency of FTR≤1H events (events per reactor year) trend for standby TDPs. Reactor Year Failures Lower Upper Lower Upper Years Mean Mean (5%) (95%) (5%) (95%) 1998 2 97.0 — — — 4.66E-03 5.73E-02 2.04E-02 1999 3 97.0 — — — 8.82E-03 6.89E-02 2.85E-02 2000 10 97.3 — — — 4.71E-02 1.43E-01 8.53E-02 2001 4 97.0 — — — 1.35E-02 8.01E-02 3.66E-02 2002 5 97.0 — — — 1.86E-02 9.10E-02 4.48E-02 2003 8 97.0 — — — 3.53E-02 1.23E-01 6.92E-02 2004 0 97.3 — — — 1.60E-05 3.17E-02 4.06E-03 2005 4 97.0 — — — 1.35E-02 8.01E-02 3.66E-02 2006 2 97.0 — — — 4.66E-03 5.73E-02 2.04E-02 2007 7 97.6 — — — 2.94E-02 1.12E-01 6.08E-02 2008 4 98.3 — — — 1.34E-02 7.93E-02 3.63E-02 2009 5 98.0 — — — 1.85E-02 9.03E-02 4.44E-02 2010 3 98.0 — — — 8.75E-03 6.83E-02 2.83E-02 2011 4 98.0 — — — 1.34E-02 7.94E-02 3.63E-02 2012 1 98.3 — — — 1.42E-03 4.46E-02 1.21E-02 2013 0 95.6 — — — 1.62E-05 3.22E-02 4.12E-03 2014 1 94.0 — — — 1.47E-03 4.62E-02 1.25E-02 2015 4 93.0 2.16E-02 6.11E-03 7.63E-02 1.40E-02 8.28E-02 3.79E-02 2016 4 93.2 1.96E-02 6.74E-03 5.69E-02 1.40E-02 8.26E-02 3.78E-02 2017 0 93.0 1.78E-02 7.24E-03 4.36E-02 1.65E-05 3.29E-02 4.21E-03 2018 3 93.0 1.61E-02 7.43E-03 3.50E-02 9.12E-03 7.12E-02 2.95E-02 2019 0 92.0 1.46E-02 7.11E-03 3.02E-02 1.67E-05 3.32E-02 4.24E-03 2020 1 90.2 1.33E-02 6.25E-03 2.83E-02 1.52E-03 4.77E-02 1.29E-02 2021 2 88.3 1.21E-02 5.09E-03 2.86E-02 5.02E-03 6.16E-02 2.19E-02 2022 1 87.4 1.10E-02 3.94E-03 3.04E-02 1.55E-03 4.89E-02 1.32E-02 2023 0 87.0 9.94E-03 2.96E-03 3.34E-02 1.74E-05 3.46E-02 4.43E-03 2024 2 87.2 9.02E-03 2.18E-03 3.74E-02 5.07E-03 6.22E-02 2.21E-02 Total 80 2,555.7 44 Table 22. Plot data for Figure 14, frequency of FTR>1H events (events per reactor year) trend for standby TDPs. Reactor Year Failures Lower Upper Lower Upper Years Mean Mean (5%) (95%) (5%) (95%) 1998 0 97.0 — — — 1.36E-05 2.70E-02 3.46E-03 1999 1 97.0 — — — 1.22E-03 3.83E-02 1.04E-02 2000 3 97.3 — — — 7.48E-03 5.84E-02 2.42E-02 2001 1 97.0 — — — 1.22E-03 3.83E-02 1.04E-02 2002 0 97.0 — — — 1.36E-05 2.70E-02 3.46E-03 2003 1 97.0 — — — 1.22E-03 3.83E-02 1.04E-02 2004 4 97.3 — — — 1.15E-02 6.79E-02 3.11E-02 2005 3 97.0 — — — 7.49E-03 5.85E-02 2.42E-02 2006 0 97.0 — — — 1.36E-05 2.70E-02 3.46E-03 2007 1 97.6 — — — 1.21E-03 3.81E-02 1.03E-02 2008 2 98.3 — — — 3.93E-03 4.82E-02 1.71E-02 2009 0 98.0 — — — 1.35E-05 2.68E-02 3.43E-03 2010 1 98.0 — — — 1.21E-03 3.80E-02 1.03E-02 2011 4 98.0 — — — 1.14E-02 6.76E-02 3.09E-02 2012 4 98.3 — — — 1.14E-02 6.74E-02 3.08E-02 2013 3 95.6 — — — 7.57E-03 5.91E-02 2.44E-02 2014 3 94.0 — — — 7.65E-03 5.97E-02 2.47E-02 2015 2 93.0 2.18E-02 1.34E-02 3.53E-02 4.07E-03 5.00E-02 1.78E-02 2016 2 93.2 1.73E-02 1.15E-02 2.61E-02 4.07E-03 5.00E-02 1.78E-02 2017 2 93.0 1.38E-02 9.72E-03 1.95E-02 4.07E-03 5.00E-02 1.78E-02 2018 2 93.0 1.09E-02 8.09E-03 1.48E-02 4.07E-03 5.00E-02 1.78E-02 2019 1 92.0 8.69E-03 6.56E-03 1.15E-02 1.26E-03 3.97E-02 1.07E-02 2020 0 90.2 6.91E-03 5.16E-03 9.24E-03 1.43E-05 2.83E-02 3.63E-03 2021 0 88.3 5.49E-03 3.95E-03 7.63E-03 1.45E-05 2.87E-02 3.68E-03 2022 0 87.4 4.36E-03 2.96E-03 6.43E-03 1.46E-05 2.89E-02 3.70E-03 2023 0 87.0 3.47E-03 2.20E-03 5.48E-03 1.46E-05 2.90E-02 3.71E-03 2024 0 87.2 2.76E-03 1.62E-03 4.71E-03 1.46E-05 2.90E-02 3.71E-03 Total 40 2,555.7 45 Table 23. Plot data for Figure 15, frequency of start demands (demands per reactor year) trend for normally running TDPs. Reactor Year Demands Lower Upper Lower Upper Years Mean Mean (5%) (95%) (5%) (95%) 1998 79 30.0 — — — 2.16E+00 3.16E+00 2.62E+00 1999 79 30.0 — — — 2.16E+00 3.16E+00 2.62E+00 2000 79 30.1 — — — 2.15E+00 3.15E+00 2.61E+00 2001 78 30.0 — — — 2.14E+00 3.14E+00 2.60E+00 2002 78 30.0 — — — 2.14E+00 3.14E+00 2.60E+00 2003 78 30.0 — — — 2.14E+00 3.14E+00 2.60E+00 2004 78 30.1 — — — 2.13E+00 3.13E+00 2.59E+00 2005 78 30.0 — — — 2.14E+00 3.14E+00 2.60E+00 2006 78 30.0 — — — 2.14E+00 3.14E+00 2.60E+00 2007 78 30.6 — — — 2.10E+00 3.08E+00 2.55E+00 2008 78 31.1 — — — 2.07E+00 3.03E+00 2.51E+00 2009 78 31.0 — — — 2.06E+00 3.02E+00 2.50E+00 2010 76 31.0 — — — 2.01E+00 2.96E+00 2.45E+00 2011 76 31.0 — — — 2.01E+00 2.97E+00 2.45E+00 2012 76 31.1 — — — 2.01E+00 2.96E+00 2.45E+00 2013 76 31.0 — — — 2.01E+00 2.97E+00 2.45E+00 2014 76 31.0 — — — 2.01E+00 2.97E+00 2.45E+00 2015 75 31.0 2.33E+00 2.26E+00 2.40E+00 1.99E+00 2.94E+00 2.43E+00 2016 72 31.3 2.32E+00 2.26E+00 2.37E+00 1.88E+00 2.80E+00 2.30E+00 2017 72 32.0 2.30E+00 2.26E+00 2.35E+00 1.84E+00 2.74E+00 2.25E+00 2018 72 32.0 2.29E+00 2.25E+00 2.33E+00 1.84E+00 2.74E+00 2.25E+00 2019 72 32.0 2.28E+00 2.24E+00 2.32E+00 1.84E+00 2.74E+00 2.25E+00 2020 72 32.1 2.27E+00 2.23E+00 2.30E+00 1.83E+00 2.73E+00 2.25E+00 2021 72 32.0 2.26E+00 2.22E+00 2.29E+00 1.84E+00 2.74E+00 2.25E+00 2022 72 32.0 2.24E+00 2.20E+00 2.29E+00 1.83E+00 2.74E+00 2.25E+00 2023 72 32.0 2.23E+00 2.18E+00 2.29E+00 1.83E+00 2.73E+00 2.25E+00 2024 72 32.1 2.22E+00 2.16E+00 2.28E+00 1.83E+00 2.73E+00 2.25E+00 Total 2,044 836.4 46 Table 24. Plot data for Figure 16, frequency of run hours (hours per reactor year) trend for normally running TDPs. Reactor Year Run Hours Lower Upper Upper Years Mean Lower (5%) Mean (5%) (95%) (95%) 1998 335,022 30.0 — — — 1.11E+04 1.12E+04 1.12E+04 1999 335,022 30.0 — — — 1.11E+04 1.12E+04 1.12E+04 2000 335,022 30.1 — — — 1.11E+04 1.12E+04 1.11E+04 2001 335,417 30.0 — — — 1.12E+04 1.12E+04 1.12E+04 2002 335,311 30.0 — — — 1.11E+04 1.12E+04 1.12E+04 2003 335,387 30.0 — — — 1.11E+04 1.12E+04 1.12E+04 2004 335,356 30.1 — — — 1.11E+04 1.12E+04 1.11E+04 2005 335,371 30.0 — — — 1.11E+04 1.12E+04 1.12E+04 2006 335,356 30.0 — — — 1.11E+04 1.12E+04 1.12E+04 2007 335,387 30.6 — — — 1.09E+04 1.10E+04 1.10E+04 2008 335,432 31.1 — — — 1.08E+04 1.08E+04 1.08E+04 2009 333,290 31.0 — — — 1.07E+04 1.08E+04 1.08E+04 2010 327,196 31.0 — — — 1.05E+04 1.06E+04 1.06E+04 2011 327,105 31.0 — — — 1.05E+04 1.06E+04 1.06E+04 2012 327,181 31.1 — — — 1.05E+04 1.06E+04 1.05E+04 2013 327,166 31.0 — — — 1.05E+04 1.06E+04 1.06E+04 2014 327,135 31.0 — — — 1.05E+04 1.06E+04 1.06E+04 2015 326,131 31.0 1.03E+04 1.01E+04 1.05E+04 1.05E+04 1.06E+04 1.05E+04 2016 321,356 31.3 1.02E+04 1.01E+04 1.04E+04 1.02E+04 1.03E+04 1.03E+04 2017 321,325 32.0 1.02E+04 1.01E+04 1.03E+04 1.00E+04 1.01E+04 1.00E+04 2018 321,280 32.0 1.02E+04 1.01E+04 1.03E+04 1.00E+04 1.01E+04 1.00E+04 2019 321,386 32.0 1.01E+04 1.00E+04 1.02E+04 1.00E+04 1.01E+04 1.00E+04 2020 321,325 32.1 1.01E+04 9.99E+03 1.02E+04 9.99E+03 1.00E+04 1.00E+04 2021 321,386 32.0 1.01E+04 9.94E+03 1.02E+04 1.00E+04 1.01E+04 1.00E+04 2022 321,447 32.0 1.00E+04 9.89E+03 1.01E+04 1.00E+04 1.01E+04 1.00E+04 2023 321,325 32.0 9.98E+03 9.83E+03 1.01E+04 1.00E+04 1.01E+04 1.00E+04 2024 321,280 32.1 9.94E+03 9.76E+03 1.01E+04 9.98E+03 1.00E+04 1.00E+04 Total 8,875,397 836.4 47 Table 25. Plot data for Figure 17, frequency of FTS events (events per reactor year) trend for normally running TDPs. Reactor Year Failures Lower Upper Lower Upper Years Mean Mean (5%) (95%) (5%) (95%) 1998 2 30.0 — — — 6.11E-03 7.51E-02 2.67E-02 1999 2 30.0 — — — 6.11E-03 7.51E-02 2.67E-02 2000 0 30.1 — — — 2.10E-05 4.17E-02 5.33E-03 2001 1 30.0 — — — 1.88E-03 5.91E-02 1.60E-02 2002 0 30.0 — — — 2.10E-05 4.17E-02 5.34E-03 2003 0 30.0 — — — 2.10E-05 4.17E-02 5.34E-03 2004 0 30.1 — — — 2.10E-05 4.17E-02 5.33E-03 2005 3 30.0 — — — 1.16E-02 9.03E-02 3.74E-02 2006 1 30.0 — — — 1.88E-03 5.91E-02 1.60E-02 2007 0 30.6 — — — 2.08E-05 4.14E-02 5.30E-03 2008 0 31.1 — — — 2.07E-05 4.12E-02 5.28E-03 2009 1 31.0 — — — 1.86E-03 5.85E-02 1.58E-02 2010 0 31.0 — — — 2.08E-05 4.13E-02 5.28E-03 2011 0 31.0 — — — 2.08E-05 4.13E-02 5.28E-03 2012 1 31.1 — — — 1.86E-03 5.84E-02 1.58E-02 2013 1 31.0 — — — 1.86E-03 5.85E-02 1.58E-02 2014 0 31.0 — — — 2.08E-05 4.13E-02 5.28E-03 2015 0 31.0 7.87E-03 3.90E-03 1.59E-02 2.08E-05 4.13E-02 5.28E-03 2016 1 31.3 7.55E-03 4.16E-03 1.37E-02 1.85E-03 5.83E-02 1.58E-02 2017 0 32.0 7.24E-03 4.38E-03 1.19E-02 2.05E-05 4.08E-02 5.23E-03 2018 0 32.0 6.94E-03 4.54E-03 1.06E-02 2.05E-05 4.08E-02 5.23E-03 2019 0 32.0 6.66E-03 4.56E-03 9.72E-03 2.05E-05 4.08E-02 5.23E-03 2020 1 32.1 6.38E-03 4.40E-03 9.27E-03 1.84E-03 5.78E-02 1.57E-02 2021 0 32.0 6.12E-03 4.07E-03 9.22E-03 2.05E-05 4.08E-02 5.23E-03 2022 0 32.0 5.87E-03 3.64E-03 9.48E-03 2.05E-05 4.08E-02 5.23E-03 2023 0 32.0 5.63E-03 3.19E-03 9.95E-03 2.05E-05 4.08E-02 5.23E-03 2024 0 32.1 5.40E-03 2.76E-03 1.06E-02 2.05E-05 4.08E-02 5.22E-03 Total 14 836.4 48 Table 26. Plot data for Figure 18, frequency of FTR events (events per reactor year) trend for normally running TDPs. Reactor Year Failures Lower Upper Lower Upper Years Mean Mean (5%) (95%) (5%) (95%) 1998 1 30.0 — — — 4.21E-03 1.32E-01 3.59E-02 1999 6 30.0 — — — 7.05E-02 2.99E-01 1.56E-01 2000 2 30.1 — — — 1.37E-02 1.68E-01 5.97E-02 2001 3 30.0 — — — 2.59E-02 2.02E-01 8.37E-02 2002 3 30.0 — — — 2.59E-02 2.02E-01 8.37E-02 2003 6 30.0 — — — 7.05E-02 2.99E-01 1.56E-01 2004 3 30.1 — — — 2.59E-02 2.02E-01 8.36E-02 2005 6 30.0 — — — 7.05E-02 2.99E-01 1.56E-01 2006 3 30.0 — — — 2.59E-02 2.02E-01 8.37E-02 2007 3 30.6 — — — 2.56E-02 1.99E-01 8.25E-02 2008 3 31.1 — — — 2.53E-02 1.97E-01 8.16E-02 2009 3 31.0 — — — 2.53E-02 1.98E-01 8.18E-02 2010 6 31.0 — — — 6.88E-02 2.92E-01 1.52E-01 2011 2 31.0 — — — 1.34E-02 1.64E-01 5.84E-02 2012 6 31.1 — — — 6.87E-02 2.91E-01 1.52E-01 2013 4 31.0 — — — 3.88E-02 2.30E-01 1.05E-01 2014 2 31.0 — — — 1.34E-02 1.64E-01 5.84E-02 2015 5 31.0 1.03E-01 5.60E-02 1.88E-01 5.34E-02 2.61E-01 1.29E-01 2016 2 31.3 7.68E-02 4.60E-02 1.28E-01 1.33E-02 1.63E-01 5.80E-02 2017 3 32.0 5.75E-02 3.72E-02 8.88E-02 2.47E-02 1.93E-01 7.99E-02 2018 2 32.0 4.30E-02 2.92E-02 6.32E-02 1.31E-02 1.61E-01 5.71E-02 2019 0 32.0 3.22E-02 2.22E-02 4.67E-02 4.49E-05 8.92E-02 1.14E-02 2020 1 32.1 2.41E-02 1.62E-02 3.59E-02 4.01E-03 1.26E-01 3.42E-02 2021 0 32.0 1.80E-02 1.14E-02 2.85E-02 4.49E-05 8.92E-02 1.14E-02 2022 0 32.0 1.35E-02 7.86E-03 2.32E-02 4.49E-05 8.92E-02 1.14E-02 2023 0 32.0 1.01E-02 5.34E-03 1.91E-02 4.49E-05 8.92E-02 1.14E-02 2024 0 32.1 7.56E-03 3.60E-03 1.59E-02 4.48E-05 8.90E-02 1.14E-02 Total 75 836.4 49 9. REFERENCES [1] Houghton, J. R. and H. G. Hamzehee. 2000. “Component Performance Study – Turbine-Driven Pumps, 1987-1998,” NUREG-1715, Vol. 2, U.S. Nuclear Regulatory Commission. https://www.nrc.gov/docs/ML0037/ML003708823.pdf. [2] Ma, Z. 2023. “Enhanced Component Performance Study: Turbine-Driven Pumps 1998-2022,” INL/RPT-23-73957, Idaho National Laboratory. https://nrcoe.inl.gov/publicdocs/CompPerf/tdp-2022.pdf. [3] Gentillion, C. D. 2016. “Overview and Reference Document for Operational Experience Results and Databases Trending.” Accessed March 8, 2022. https://nrcoe.inl.gov/publicdocs/Overview-and-Reference.pdf. [4] Institute of Nuclear Power Operations. 2019. “Industry Reporting and Information System (IRIS) Reporting Requirements,” INPO 19-002, Revision 1. [5] Lane, J. C. 2015. “NRC Operating Experience (OpE) Programs,” Office of Nuclear Regulatory Research, SPAR Workshop Public Meeting, July 14–15, 2015. http://pbadupws.nrc.gov/docs/ML1518/ML15189A345.pdf. [6] Nuclear Energy Institute. 2013. “Regulatory Assessment Performance Indicator Guideline.” NEI 99-02, Revision 7, Nuclear Energy Institute. https://www.nrc.gov/docs/ML1326/ML13261A116.pdf. [7] Ma, Z., T. E. Wierman, and K. J. Kvarfordt. 2021. “Industry-Average Performance for Components and Initiating Events at U.S. Commercial Nuclear Power Plants: 2020 Update,” INL/EXT-21-65055, Idaho National Laboratory. https://nrcoe.inl.gov/publicdocs/AvgPerf/AvgPara2020.pdf. [8] Eide, S. A., T. E. Wierman, C. D. Gentillon, D. M. Rasmuson, and C. L. Atwood. 2007. “Industry- Average Performance for Components and Initiating Events at U.S. Commercial Nuclear Power Plants,” NUREG/CR-6928, U.S. Nuclear Regulatory Commission. https://www.nrc.gov/docs/ML0706/ML070650650.pdf. [9] Ma, Z. 2022. “Enhanced Component Performance Study: Turbine-Driven Pumps 1998-2020,” INL/RPT-22-66598, Idaho National Laboratory. https://nrcoe.inl.gov/publicdocs/CompPerf/tdp-2020.pdf. [10] Schroeder, J. A.. 2018. “Enhanced Component Performance Study: Turbine-Driven Pumps 1998- 2016,” INL/EXT-17-44116, Idaho National Laboratory. https://nrcoe.inl.gov/publicdocs/CompPerf/tdp-2016.pdf. [11] Atwood, C. L., et al. 2003. “Handbook of Parameter Estimation for Probabilistic Risk Assessment,” NUREG/CR-6823, U.S. Nuclear Regulatory Commission. https://www.nrc.gov/docs/ML0329/ML032900131.pdf. [12] Ma, Z, T. Liu, N. Johnson, and J.W. Merickle. 2025. “Enhanced Component Performance Study: Emergency Diesel Generators 1998–2024,” INL/RPT-25-86864, Idaho National Laboratory. https://nrcoe.inl.gov/publicdocs/CompPerf/edg-2024.pdf. 50