Read A Way to Picometer X-ray Displacement Sensing and Nanometer Resolution 3D X-ray Micro-Tomography by Li Hua Yu (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2512-17863.txt.
Introduction
Li Hua Yu proposes a new way to sense tiny shifts and to image small objects with X-rays. His two point propagation field tracks how the chance of catching a single photon changes when a speck blocks part of the path. Near the detector slit, that field ripples with a period of only 4 to 7 nanometers.
Those ripples could let a setup sense shifts near 200 picometers, far below the size of an atom, using 6 keV X-rays. The same field reshapes scan data in a way that may allow 3D images without slow step by step solving. The paper lays the groundwork for such tools.
Catalog record
| CREATOR | Li Hua Yu |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 98 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2512-17863
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
A Way to Picometer X-ray Displacement Sensing and Nanometer Resolution 3D X-ray Micro-Tomography Li Hua Yu Abstract We introduce the two-point propagation field (TPPF)—a real-valued, phase-sensitive quantity defined as the functional derivative of the single-photon detection probability with respect to an infinitesimal opaque perturbation placed between source and detection slits. The TPPF is analytically derived and shown to exhibit stable, high-frequency sinusoidal structure ( ≈ \approx 6.7 nm period) near the detection slit. This structure enables shot-noise-limited displacement sensing at ∼ \sim 15 pm precision using routinely available synchrotron fluxes and practical nanofabricated slit/comb geometries, requiring mechanical stability only over the final 0.5 mm. The same principle provides a foundation for future nanometer-resolution 3D X-ray micro-tomography of bulk samples with potentially reduced radiation dose. Two conceptual strategies—a central blocker and off-axis multi-slit arrays—are estimated to lower the required incident fluence by more than one order of magnitude each, yielding combined reductions of two to three orders of magnitude with near-term detector development. The TPPF concept, originally developed in a perturbative study of single-particle propagation, thus bridges fundamental quantum measurement questions with practical high-resolution X-ray metrology and imaging. 1. Introduction and Motivation This technical note outlines a new theoretical concept—the two-point propagation field (TPPF)—that may offer a practical basis for achieving shot-noise-limited X-ray displacement sensing at \sim 15 pm precision with existing synchrotron beamlines and practical slit-comb geometries. This approach addresses key limitations in current tomography, such as relative sample-beam motion restricting resolution to \sim 4 nm swiss_tomography_4nm , and is rooted in the two-point propagation field (TPPF), a real-valued, phase-sensitive function derived from perturbative analysis of single-particle propagation. TPPF is derived from the perturbative response of detection rates to localized perturbations—such as placing a thin opaque pin to block the wave—at intermediate points along the photon propagation path between a source slit and a detection slit. This quantity, referred to as the two-point propagation field (TPPF), was introduced and derived in detail in a recent theoretical study yu-1 , where it was originally termed the "perturbative function." The central idea is that this function captures projection-like information about a sample’s internal structure by encoding how the count rate at a detector changes when the wave is perturbed by a pin at different points. When we replace the perturbation pin with a sample as the perturbation, the detection rate becomes a function of the position and the angle of the sample orientation. The function is a convolution between the TPPF and the sample’s structural function. The result is a stable, reproducible function that varies with the scan position and angle of the sample, and may be viewed as analogous to the projection data used in Radon-transform-based reconstruction techniques. However, in this case, the measured signal is directly related to the Fourier transform of the Radon transform, due to the high-frequency phase information inherent in the TPPF. Although this work does not address reconstruction techniques directly, the structure of the TPPF suggests a possible path toward extending classical tomographic methods to single-particle quantum systems—particularly in efforts to resolve nanometer-scale structural features. This note presents the TPPF formula, its physical interpretation, and a proposed connection to projection-based 3D-tomography 3Dtomo_flann ; 3Dtomo_path . The goal is to communicate this idea clearly to researchers in 3D imaging and X-ray science, and to explore whether the method can be experimentally tested and integrated into an existing tomographic method. In the first step in this direction, the analysis leads to practical shot-noise-limited displacement sensing at \sim 15 pm precision with existing synchrotron beamlines and practical slit/comb geometries. Such precision enables lensless, counting-based sensors that require stability only over the final 0.5 mm propagation distance, utilizing routine fluxes from synchrotron or XFEL sources (e.g., ~10^{11} to 10^{13}) incident photons, depending on slit configurations. This step itself is useful for the advance of x-ray tomography because the motion between the x-ray beam and the sample of order of 4 nm is one of the limitations of tomography resolution swiss_tomography_4nm . By encoding high-frequency phase information akin to a Fourier-transformed Radon projection (Section 3), the TPPF supports reconstruction of internal structures at nanometer scales, offering a pathway to lower-dose imaging compared to conventional ptychography or burst methods. This not only facilitates experimental validation of the TPPF but also reduces radiation damage in biological samples potentially by more than one order of magnitude through strategies like central blockers or off-axis slit arrays, as explored in Sections 5 and 6. Section 2 introduces the two-point propagation function (TPPF). Section 3 examines its connection to the Radon transform and 3D tomography. In Section 4, we discuss how cascaded double or triple slit configurations can enable nanometer resolution using existing technology. In Section 5, we present the calculation of 4 practical options for a lensless picometer X-ray displacement sensor, one of our main result of this work, which bridge the TPPF testing and the further exploration of the new x-ray tomography method. Section 6 describes ongoing work for a significant reduction of the photon flux required. Section 7 discusses the relation between TPPF and the quantum measurement during the free space propagation between the source and the detector slit. Section 8 is the conclusion. This work is approached from a theoretical standpoint, using broadly referenced parameters to assess the feasibility of a picometer x-ray displacement sensor and the nanometer-resolution 3D tomography. Although not based on direct experience with experimental tomography or biological imaging, the analysis is intended to provide a foundation for discussion and further evaluation by experts in these areas. 2. Description of the Experiment to Measure the Two-point Propagation Field 2.1 TPPF and its physical interpretation As illustrated in Figure 1 (a), we analyze the wave function evolution of a particle when it propagates through free space in the longitudinal z -direction from a thin entrance slit 1 to a detector behind a thin exit slit 2 to find the information about whether the wave function collapse occurs at the entrance slit 1 or the exit slit 2. The slits are parallel to the y -axis (perpendicular to the plane of the figure). The x -axis is vertical in the figure. Between the slits, the wave function must follow the Schrödinger equation because the only non-unitary (irreversible) process is at the slits. Only the particles that pass through the slits are selected and detected. The probability of a particle found between z_{1} and z_{2} is a constant independent of z due to particle number conservation. We insert a thin pin \chi(x)=1+\Delta\chi(x) between the two slits at position z,x to cut off the wave function as a perturbation. When \Delta\chi(x)=0 , there is no pin. When \Delta\chi(x,z)=-1 within a thin section \Delta x around a point at (x,z), it represents a thin pin. When |\Delta\chi(x,z)|\ll 1 in an extended area, it becomes a sample as a perturbation. The caption for Fig. 1(a) gives the notations. In Fig. 1 (a), we study the effect of a perturbation \Delta\chi(x) on the counting rate P_{2b}=\int_{-\infty}^{\infty}dx_{2}|\psi_{2b}(x_{2})|^{2} , and calculate the ratio of the counting rate change over the perturbation. As the perturbation approaches zero, the ratio \frac{\Delta P_{2b}}{\Delta\chi(x,z)} becomes the functional derivative \frac{\delta P_{2b}}{\delta\chi(x,z)} of the counting rate over the perturbation \Delta\chi(x) . This perturbative function is