A Way to Picometer X-ray Displacement Sensing and Nanometer Resolution 3D X-ray Micro-Tomography Li Hua Yu Abstract We introduce the two-point propagation field (TPPF)—a real-valued, phase-sensitive quantity defined as the functional derivative of the single-photon detection probability with respect to an infinitesimal opaque perturbation placed between source and detection slits. The TPPF is analytically derived and shown to exhibit stable, high-frequency sinusoidal structure ( ≈ \approx 6.7 nm period) near the detection slit. This structure enables shot-noise-limited displacement sensing at ∼ \sim 15 pm precision using routinely available synchrotron fluxes and practical nanofabricated slit/comb geometries, requiring mechanical stability only over the final 0.5 mm. The same principle provides a foundation for future nanometer-resolution 3D X-ray micro-tomography of bulk samples with potentially reduced radiation dose. Two conceptual strategies—a central blocker and off-axis multi-slit arrays—are estimated to lower the required incident fluence by more than one order of magnitude each, yielding combined reductions of two to three orders of magnitude with near-term detector development. The TPPF concept, originally developed in a perturbative study of single-particle propagation, thus bridges fundamental quantum measurement questions with practical high-resolution X-ray metrology and imaging. 1. Introduction and Motivation This technical note outlines a new theoretical concept—the two-point propagation field (TPPF)—that may offer a practical basis for achieving shot-noise-limited X-ray displacement sensing at \sim 15 pm precision with existing synchrotron beamlines and practical slit-comb geometries. This approach addresses key limitations in current tomography, such as relative sample-beam motion restricting resolution to \sim 4 nm swiss_tomography_4nm , and is rooted in the two-point propagation field (TPPF), a real-valued, phase-sensitive function derived from perturbative analysis of single-particle propagation. TPPF is derived from the perturbative response of detection rates to localized perturbations—such as placing a thin opaque pin to block the wave—at intermediate points along the photon propagation path between a source slit and a detection slit. This quantity, referred to as the two-point propagation field (TPPF), was introduced and derived in detail in a recent theoretical study yu-1 , where it was originally termed the "perturbative function." The central idea is that this function captures projection-like information about a sample’s internal structure by encoding how the count rate at a detector changes when the wave is perturbed by a pin at different points. When we replace the perturbation pin with a sample as the perturbation, the detection rate becomes a function of the position and the angle of the sample orientation. The function is a convolution between the TPPF and the sample’s structural function. The result is a stable, reproducible function that varies with the scan position and angle of the sample, and may be viewed as analogous to the projection data used in Radon-transform-based reconstruction techniques. However, in this case, the measured signal is directly related to the Fourier transform of the Radon transform, due to the high-frequency phase information inherent in the TPPF. Although this work does not address reconstruction techniques directly, the structure of the TPPF suggests a possible path toward extending classical tomographic methods to single-particle quantum systems—particularly in efforts to resolve nanometer-scale structural features. This note presents the TPPF formula, its physical interpretation, and a proposed connection to projection-based 3D-tomography 3Dtomo_flann ; 3Dtomo_path . The goal is to communicate this idea clearly to researchers in 3D imaging and X-ray science, and to explore whether the method can be experimentally tested and integrated into an existing tomographic method. In the first step in this direction, the analysis leads to practical shot-noise-limited displacement sensing at \sim 15 pm precision with existing synchrotron beamlines and practical slit/comb geometries. Such precision enables lensless, counting-based sensors that require stability only over the final 0.5 mm propagation distance, utilizing routine fluxes from synchrotron or XFEL sources (e.g., ~10^{11} to 10^{13}) incident photons, depending on slit configurations. This step itself is useful for the advance of x-ray tomography because the motion between the x-ray beam and the sample of order of 4 nm is one of the limitations of tomography resolution swiss_tomography_4nm . By encoding high-frequency phase information akin to a Fourier-transformed Radon projection (Section 3), the TPPF supports reconstruction of internal structures at nanometer scales, offering a pathway to lower-dose imaging compared to conventional ptychography or burst methods. This not only facilitates experimental validation of the TPPF but also reduces radiation damage in biological samples potentially by more than one order of magnitude through strategies like central blockers or off-axis slit arrays, as explored in Sections 5 and 6. Section 2 introduces the two-point propagation function (TPPF). Section 3 examines its connection to the Radon transform and 3D tomography. In Section 4, we discuss how cascaded double or triple slit configurations can enable nanometer resolution using existing technology. In Section 5, we present the calculation of 4 practical options for a lensless picometer X-ray displacement sensor, one of our main result of this work, which bridge the TPPF testing and the further exploration of the new x-ray tomography method. Section 6 describes ongoing work for a significant reduction of the photon flux required. Section 7 discusses the relation between TPPF and the quantum measurement during the free space propagation between the source and the detector slit. Section 8 is the conclusion. This work is approached from a theoretical standpoint, using broadly referenced parameters to assess the feasibility of a picometer x-ray displacement sensor and the nanometer-resolution 3D tomography. Although not based on direct experience with experimental tomography or biological imaging, the analysis is intended to provide a foundation for discussion and further evaluation by experts in these areas. 2. Description of the Experiment to Measure the Two-point Propagation Field 2.1 TPPF and its physical interpretation As illustrated in Figure 1 (a), we analyze the wave function evolution of a particle when it propagates through free space in the longitudinal z -direction from a thin entrance slit 1 to a detector behind a thin exit slit 2 to find the information about whether the wave function collapse occurs at the entrance slit 1 or the exit slit 2. The slits are parallel to the y -axis (perpendicular to the plane of the figure). The x -axis is vertical in the figure. Between the slits, the wave function must follow the Schrödinger equation because the only non-unitary (irreversible) process is at the slits. Only the particles that pass through the slits are selected and detected. The probability of a particle found between z_{1} and z_{2} is a constant independent of z due to particle number conservation. We insert a thin pin \chi(x)=1+\Delta\chi(x) between the two slits at position z,x to cut off the wave function as a perturbation. When \Delta\chi(x)=0 , there is no pin. When \Delta\chi(x,z)=-1 within a thin section \Delta x around a point at (x,z), it represents a thin pin. When |\Delta\chi(x,z)|\ll 1 in an extended area, it becomes a sample as a perturbation. The caption for Fig. 1(a) gives the notations. In Fig. 1 (a), we study the effect of a perturbation \Delta\chi(x) on the counting rate P_{2b}=\int_{-\infty}^{\infty}dx_{2}|\psi_{2b}(x_{2})|^{2} , and calculate the ratio of the counting rate change over the perturbation. As the perturbation approaches zero, the ratio \frac{\Delta P_{2b}}{\Delta\chi(x,z)} becomes the functional derivative \frac{\delta P_{2b}}{\delta\chi(x,z)} of the counting rate over the perturbation \Delta\chi(x) . This perturbative function is independent of perturbation, it is a real-valued function containing high-resolution phase information, determined solely by the two-slit geometry in our 2D study, as we will show in the following. It can be measured with high precision and reproducibility, and it uniquely characterizes the individual event of a particle propagating between the two slits. Unlike a probability amplitude, it manifests as a stable, reproducible structure that we interpret as consistent with an objectively existing field, which we define as the two-point propagation field (TPPF). The TPPF does not correspond to a probability distribution. While the wave function describes an ensemble of possible detection outcomes, the TPPF characterizes the process underlying a single detection — a realization selected according to the Born rule. Figure 1: (a) Experimental geometry (not to scale) . The wave functions at slits 1,2 at z_{1},z_{2} with apertures \sigma_{1},\sigma_{2} and corresponding transverse displacements s_{1},s_{2} in the x-direction, and a pin \chi(x) at z,x_{p} of width \sigma_{\chi} . The distances between the slits and the pin are z,L-z, and L. The longitudinal is the z -axis, the x-axis is vertical in this figure. The slits are perpendicular to the plane of the figure, parallel to the y -axis. We use \psi_{1}(x_{1},z_{1}) , \psi(x,z), \psi_{2a}(x_{2},z_{2}) and \psi_{2b}(x_{2},z_{2}) to represent the wave function at the entrance, the pin and the exit, respectively. The subscripts a and b represent before and after slit 2. We use f_{1}(x_{1}) and f_{2}(x_{2}) to represent the effect of the slits such that \psi_{1}(x_{1},z_{1})\equiv f_{1}(x_{1}),\psi_{2b}(x_{2},z_{2})=f_{2}(x_{2})\psi_{2a}(x_{2},z_{2}) . If we choose the slit with the hard-edged opening, f_{1}(x_{1}) and f_{2}(x_{2}) would be zero outside the slits and equal to 1 within the slits. To simplify the calculation, we assume they are Gaussian with peak value 1, except that we choose f_{1}(x_{1}) to normalize \psi_{1} as P_{1}=\int dx_{1}|\psi_{1}(x_{1},z_{1}=0)|^{2}=1 . The pin profile is \chi(x)=1 when it is removed. When inserted, \chi(x)=1-\exp(-\frac{1}{2\sigma_{\chi}^{2}}\left(x-x_{p}\right)^{2}) ; effective width (equivalent hard-edged slit width) is \Delta x=\sqrt{2\pi}\sigma_{\chi} . (b)The wave function of a single particle spreads over a wide region after emission and collapses instantaneously upon detection In Appendix II we outline a derivation of the calculation of TPPF using the basics of quantum mechanics. Since in this work we consider X-ray 3D tomography, for the case in Fig. 1 (a) and for sufficiently long and narrow slits and pin, we neglect the y dependence and assume a 2D Maxwell equation \frac{1}{c^{2}}\frac{\partial^{2}}{\partial t^{2}}\phi(x,z,t)=\left(\frac{\partial^{2}}{\partial x^{2}}+\frac{\partial^{2}}{\partial z^{2}}\right)\phi(x,z,t), (1) because we do not consider polarization, we just use \phi to denote any component of the electromagnetic field. We assume k=\frac{\omega}{c} , \phi(x,z,t)=e^{i(kz-\omega t)}\psi(x,z) , take the paraxial approximation: | \frac{\partial^{2}}{\partial z^{2}}\psi|\ll|\frac{\partial^{2}}{\partial x^{2}}\psi |, | \frac{\partial^{2}}{\partial z^{2}}\psi|\ll 2k|\frac{\partial}{\partial z}\psi |, we get the 1D Schrӧdinger equation i\frac{\partial}{\partial z}\psi=-\frac{1}{2k}\frac{\partial^{2}}{\partial x^{2}}\psi . \psi is the slowly varying amplitude and phase of the wave function. We can characterize the experiment by specifying the wavelength \lambda=\frac{2\pi}{k} only. The Green’s function from slit 1 to slit 2 is \displaystyle G(x_{2},x_{1};z_{2},z_{1})=\left(\frac{k}{2\pi i(z_{2}-z_{1})}\right)^{\frac{1}{2}}\exp\left[i\frac{k}{2(z_{2}-z_{1})}\left(x_{2}-x_{1}\right)^{2}\right] (2) The initial wave function \psi_{1}(x_{1},z_{1})\equiv f_{1}(x_{1})=\left(\frac{1}{2\pi\sigma_{1}^{2}}\right)^{\frac{1}{4}}\exp(-\frac{1}{4\sigma_{1}^{2}}(x_{1}-s_{1})^{2}) is the Gaussian profile of slit 1, f_{2}=\exp(-\frac{1}{4\sigma_{2}^{2}}(x_{2}-s_{2})^{2}) is for slit 2. Our analysis shows that for the narrow slits we considered, replacing the Gaussian profile by a hard-edge profile of width \sqrt{2\pi}\sigma_{2} would only cause a negligible difference, while the Gaussian profile allows us to derive a simple analytical result to be described in Section 2.2. In the derivation of the TPPF, the Green’s functions G(x,x_{1} ), G(x_{2},x ) are given by replacing the corresponding variables in Eq.( 2 ). When wave function at the entrance slit 1 is normalized as \psi_{1}(x_{1},z_{1})\equiv f_{1}(x_{1}) , applying the property of the Green’s function, without the pin, the wave function at the exit of slit 2 is \psi_{2b}(x_{2})=f_{2}(x_{2})\int_{-\infty}^{\infty}dxG(x_{2},x;t_{2}-t)\int_{-\infty}^{\infty}dx_{1}G(x,x_{1};t-t_{1})f_{1}(x_{1}) . When there is a perturbation \chi(x)=1+\Delta\chi(x) of a pin, the wave function after the slit 2 is \psi_{2b}(x_{2})+\Delta\psi_{2b}(x_{2})=f_{2}(x_{2})\int_{-\infty}^{\infty}dxG(x_{2},x;t_{2}-t)\left(1+\Delta\chi(x)\right)\int_{-\infty}^{\infty}dx_{1}G(x,x_{1};t-t_{1})f_{1}(x_{1}) (3) The increment for infinitesimal \Delta x is \displaystyle\Delta\psi_{2b}(x_{2})=f_{2}(x_{2})\int_{-\infty}^{\infty}dxG(x_{2},x;t_{2}-t)\Delta\chi(x)\int_{-\infty}^{\infty}dx_{1}G(x,x_{1};t-t_{1})f_{1}(x_{1}) \displaystyle=-\int_{x}^{x+\Delta x}dxf_{2}(x_{2})G(x_{2},x;t_{2}-t)\int_{-\infty}^{\infty}dx_{1}G(x,x_{1};t-t_{1})f_{1}(x_{1}) \displaystyle=-\Delta xf_{2}(x_{2})G(x_{2},x;t_{2}-t)\int_{-\infty}^{\infty}dx_{1}G(x,x_{1};t-t_{1})f_{1}(x_{1}) Thus the functional derivaive of \psi_{2b}(x_{2}) over the perturbation is \displaystyle\frac{\delta\psi_{2b}(x_{2})}{\delta\chi(x,z)}=\frac{\Delta\psi_{2b}(x_{2})}{\Delta x}=-f_{2}(x_{2})G(x_{2},x;t_{2}-t)\int_{-\infty}^{\infty}dx_{1}G(x,x_{1};t-t_{1})f_{1}(x_{1}) (4) The TPPF is the functional derivative of the detection probability P_{2b}=\int_{-\infty}^{\infty}dx_{2}|\psi_{2b}(x_{2})|^{2} over the perturbation \Delta\chi(x) , and we define the complext part of TPPF as \frac{\delta P_{2b}^{(c)}}{\delta\chi(x,z)}\equiv\int_{-\infty}^{\infty}dx_{2}\frac{\delta\psi_{2b}(x_{2})}{\delta\chi(x,z)}\psi_{2b}^{*}(x_{2}) , we have, \displaystyle\frac{\delta P_{2b}}{\delta\chi(x,z)}=\int_{-\infty}^{\infty}dx_{2}\frac{\delta\psi_{2b}(x_{2})}{\delta\chi(x,z)}\psi_{2b}^{*}(x_{2})+\int_{-\infty}^{\infty}dx_{2}\psi_{2b}(x_{2})\frac{\delta\psi_{2b}^{*}(x_{2})}{\delta\chi(x,z)}\equiv\frac{\delta P_{2b}^{(c)}}{\delta\chi(x,z)}+c.c. (5) Applying Eq.( 4 ) , we have the complex TPPF \displaystyle\frac{\delta P_{2b}^{(c)}}{\delta\chi(x,z)}=-\int_{-\infty}^{\infty}dx_{2}\int_{-\infty}^{\infty}dx_{1}\psi_{2b}^{*}(x_{2})f_{2}(x_{2})G(x_{2},x;t_{2}-t)G(x,x_{1};t-t_{1})f_{1}(x_{1}) \displaystyle=\int_{-\infty}^{\infty}dx_{2}f_{2}^{2}(x_{2})G(x_{2},x;t_{2}-t)\int_{-\infty}^{\infty}dx_{1}G(x-x_{1},x_{1};t-t_{1})f_{1}(x_{1})\int_{-\infty}^{\infty}dx^{\prime}_{1}G^{*}(x_{2}-x^{\prime}_{1};t_{2}-t_{1})f_{1}(x^{\prime}_{1}) (6) The last step shows there is a simple relation between TPPF and the probability P_{2b} , i.e. \displaystyle\int_{-\infty}^{\infty}dx\frac{\delta P_{2b}^{(c)}}{\delta\chi(x,z)}=\int_{-\infty}^{\infty}dx_{2}f_{2}^{2}(x_{2})\left(\int_{-\infty}^{\infty}dxG(x_{2},x;t_{2}-t)\int_{-\infty}^{\infty}dx_{1}G(x-x_{1},x_{1};t-t_{1})f_{1}(x_{1})\right)\psi_{2a}^{*}(x_{2}) \displaystyle=\int_{-\infty}^{\infty}dx_{2}f_{2}^{2}(x_{2})\psi_{2a}(x_{2})\psi_{2a}^{*}(x_{2})=\int_{-\infty}^{\infty}dx_{2}\psi_{2b}(x_{2})\psi_{2b}^{*}(x_{2})=P_{2b} \displaystyle P_{2b}=\frac{1}{2}\int_{-\infty}^{\infty}dx\frac{\delta P_{2b}^{(c)}}{\delta\chi(x,z)}+c.c.=\frac{1}{2}\int_{-\infty}^{\infty}dx\frac{\delta P_{2b}}{\delta\chi(x,z)} (7) Thus, the integration of TPPF over x is not the probability but twice of it. An important observation is that \frac{1}{2P_{2b}}\frac{\delta P_{2b}}{\delta\chi(x,z)} is a function of z , i.e. the position z of the pin, but \frac{1}{2P_{2b}}\int_{-\infty}^{\infty}dx\frac{\delta P_{2b}}{\delta\chi(x,z)}=1 is independent of z and represents the particle number consevation during the free propagation in free space. Although the two-point propagation field (TPPF) is not positive-definite, its integral over space yields a conserved total probability. When normalized and scaled by h\nu , it acquires the dimensions of energy density and integrates to the particle’s total energy. The possibility of local negative values is not without precedent; similar behavior occurs in quantum field theory, such as in the Casimir effect casimir . We therefore interpret the scaled TPPF as a generalized energy density associated with the spatial structure of single-particle propagation. Since \frac{1}{2P_{2b}}\frac{\delta P_{2b}}{\delta\chi(x,z)} is the real part of the complex-valued \frac{\delta P_{2b}^{(c)}}{\delta\chi(x,z)} , its imaginary part—and thus the full complex derivative—can be readily obtained via a Hilbert transform hilbert_tranform by multiplying the coefficients of the Fourier transform of \frac{1}{2P_{2b}}\frac{\delta P_{2b}}{\delta\chi(x,z)} by a constant accoding to the sign of the frequency of the term (see Appendix A) and followed by an inverse Fourier transform. As we shall show, \psi(x,z) and \frac{1}{2P_{2b}}\frac{\delta P_{2b}}{\delta\chi(x,z)} are entirely different functions: \psi(x,z) is wide spread as illustrated in Fig. 1 (b), however \frac{1}{2P_{2b}}\frac{\delta P_{2b}}{\delta\chi(x,z)} becomes wide spread only in between the two slits and finaly converges into the slit 2. This answered the fundamental question: the evolution of the energy distribution h\nu is continuous without sudden collapse at the detector, as suggested by the TPPF model, even though the wave function \psi(x) collapses at the instant of the detection. \psi(x) represents a statistical distribution of the ensemble, while \frac{1}{2P_{2b}}\frac{\delta P_{2b}}{\delta\chi(x,z)} represents an individual realization of the ensemble. 2.2 The Expression of TPPF and its Difference from the Wave Function \psi(x) This simple relation between TPPF and counting rate in Eq.( 7 ) is used in simplifying the derivation of the complex TPPF Eq.( 6 ) in Appendix II. The result for the counting rate (i.e., the probability) P_{2b} and the explicit complex valued TPPF \frac{\delta P_{2b}^{(c)}}{\delta\chi(x,z)} is simpler when expressed in terms of a few scaled parameters for slits width, and longitudinal position: \mu\equiv\frac{4\pi\sigma_{1}^{2}}{\lambda L}=\frac{2k\sigma_{1}^{2}}{L},\rho\equiv\frac{\sigma_{2}^{2}}{\sigma_{1}^{2}} , z_{2}=L, z_{1}=0,z=\xi L : \displaystyle P_{2b}=\sqrt{\frac{\mu^{2}\rho}{\mu^{2}+\rho\mu^{2}+1}}\exp\left(-\frac{1}{2\sigma_{1}^{2}}{\displaystyle\frac{\mu^{2}}{\mu^{2}+1+\mu^{2}\rho}}(s_{1}-s_{2})^{2}\right) \displaystyle\frac{\delta P_{2b}^{(c)}}{\delta\chi(x,z)}=P_{2b}\frac{\sqrt{-\alpha_{\chi}}}{\sqrt{\pi}}\exp\left({\displaystyle\alpha_{\chi}\left(x-x_{c}\right)^{2}}\right) (8) \displaystyle\alpha_{\chi}=-\frac{1}{2\sigma_{1}^{2}}\frac{i\mu{\displaystyle\left(\mu^{2}+\rho\mu^{2}+1\right)}}{\left(-i\mu+\xi\right)\left(\mu{\displaystyle\left(i\xi-\mu\right)}\rho+2\left(\xi-1\right)\left(i\mu+1\right)\right)} Here x_{c}=\frac{{\displaystyle c_{S1}}s_{1}+{\displaystyle c_{S2}}s_{2}}{{\displaystyle\mu^{2}+\rho\mu^{2}+1}}, s_{1},s_{2} are the transverse displacement of the slits in Fig. 1 (a), and {\displaystyle c_{S1}}\equiv{\displaystyle\rho\mu^{2}-\left(i\mu+1\right)}\left(\xi-1\right) , {\displaystyle c_{S2}}\equiv{\displaystyle\left(\mu-i\right)\left(\mu+i\xi\right)} . For the next discussion on the tomography, we only consider the case of s_{1}=s_{2}=0 , thus x_{c}=0 , and hence TPPF is characterized mainly by the probability P_{2b} and \alpha_{\chi} that provides the information about the distribution width, fringe spacing, and frequency bandwidth. etc. of TPPF. In the example in Fig. 2 (a), we display the TPPF using a color scale for a case of \lambda=0.541 nm with the setup parameters in Fig.1. The red contour in Fig. 2 (a) is also plotted as the contour of main peak for the case of s_{2}=50\mu m in Fig. 3 , where we show several different contours of the main peaks for s_{2}=0,25,50,75\mu m respectively, to show the different realizations of the ensemble represented by the Schrӧdinger equation solution, the wave function \psi(x) with initial condition \psi_{1}(x_{1},z_{1})\equiv f_{1}(x_{1}) . Fig. 2 (b,c,d) shows several regions in Fig. 2 (a) near the exit slit 2 with details important for the next micro-tomography discussion. In particular, Fig. 2 (b) shows that the evolution of the TPPF is continuous from z=0.498 m to Z=0.5 m at the exit. To compare TPPF with \psi(x) , the RMS of |\psi(x,z)|^{2} is shown in Fig. 3 , as the thick dashed cyan line, showing its width continues to spread till the exit screen. Fig. 3 shows the contours of TPPF’s central peak emitted from slit 1 with the shape of a spindle projected in different directions; their width increases to a maximum in the middle at about 0.25m from the end at 0.5 m. The width of the central peak decreases after the maximum and finally, without a lens or focusing device, converges into the end slits. When the slit 2 is much narrower than the slit 1, as for the case of Fig. 2 , the two sides of the central peaks are wave packets with increasing width like the the width of \psi(x) until very close to the exit slit 2 within a few hundreds \mu m, where they converge rapidly into the slit 2 as shown in Fig. 2 (b) and Fig. 2 (c). The rapid convergence is evident in Fig. 2 (b); in particular, comparing the horizontal and vertical scales reveals that the convergence angle is much larger than the apparent 90 degrees—despite the fact that this is free-space propagation without any focusing. This phenomenon has a profound meaning for the photon wave packet propagation: the existence of the exit slit allowing the wave packet with energy h\nu to pass through has a profound influence on the rapid convergence into the exit before it reaches the slit. In the analysis of the 1D Schrӧdinger equation i\frac{\partial}{\partial z}\psi=-\frac{1}{2k}\frac{\partial^{2}}{\partial x^{2}}\psi , we use the transformation \phi(x,z,t)=e^{i(kz-\omega t)}\psi(x,z) , to study only monochromatic photons. When we introduce energy bandwidth, and hence study the pulse structure of the wave packet, we would be able to analyze the time-dependent behavior of the photon wave packet and further explore how the exit slit influences the convergence process. This would be an important issue to be studied. The distribution of different wave packets is described by \psi(x,z) as illustrated in Fig. 1 (b). The comparison of Fig. 1 (b) and Fig. 3 clearly shows \psi(x,z) more like a water wavefront propagating in a pond while the different wave packets \frac{\delta P_{2b}^{(c)}}{\delta\chi(x,z)} of various s_{2} are more like projectiles with detailed phase information as visible fringes in Fig. 2 (a) shooting into different directions in Fig. 3 . This observation leads to the conclusion that \psi(x) represents a statistical distribution of the ensemble, while \frac{1}{2P_{2b}}\frac{\delta P_{2b}}{\delta\chi(x,z)} represents an individual realization of the ensemble. The main point is that the evolution of TPPF in Fig.2(b) further clarified the answer to a fundamental question to be addressed later in Section 7: we understand that it represents a continuous evolution of the energy distribution h\nu , unlike the sudden discontinuous collapse of the probability amplitude \psi(x,z) at the exit slit. Figure 2: For a setup in Fig. 1 (a), take \lambda=0.541nm,\sigma_{2}=0.8nm,\sigma_{1}=0.5\mu m,L=0.5m,L-z=0.5mm , Fig.2(a): \frac{\delta P_{2b}}{\delta\chi(x,z)} vs. x,z in color scale for s_{2}=50\text{$\mu$}m , P_{2b}=9.47\times 10^{-6} . Some elliptical patterns are artifact due to the limited number of points of the plot and the nearly periodic structure of the function \frac{\delta P_{2b}}{\delta\chi(x,z)} . The patterns change with the number of points of the plot, but it is hard to avoid even with pixels increased to 4\times 10^{6} in the plot. Fig.2(b): A narrow region within 2mm from the slit 2 in (a) showing the details not visible in (a). The detailed fringe structure is not visible in this plot because it is visible only when magnified, as given in the following (c) and (d) plots. The region between the two white lines (45 \mu m\sigma_{\omega}^{(b)} . As we pointed out in Section 3.3 , the frequency at x=\sigma_{w}^{(a)} is about equal to the bandwidth of |\hat{G_{a}}^{(c)}(\omega)| , i.e. \sigma_{\omega}^{(a)} . In addition, the TPPF width \sigma_{w}^{(a)}>\sigma_{w}^{(b)} too. At x=\sigma_{w}^{(a)}>\sigma_{w}^{(b)} , the frequency of G_{b}^{(c)}(x) is beyond its bandwidth \sigma_{\omega}^{(b)} , thus |G_{b}^{(c)}(x=\sigma_{w}^{(a)})| is exponentially reduced and is negligibly small compared with |G_{a}^{(c)}(x=\sigma_{w}^{(a)})| . Hence for the Radon Fourier transform scan at the width s=\sigma_{w}^{(a)} , G^{(c)}(x=\sigma_{w}^{(a)})=C_{a}G_{a}^{(c)}(x=\sigma_{w}^{(a)}) , in simple term this means at the beam waist of slit a, the TPPF is only determined by slit a, the contribution from slit b is negligible. Similarly, at the bandwidth \omega=\sigma_{\omega}^{(a)} , \hat{G}^{(c)}(\omega=\sigma_{\omega}^{(a)})=C_{a}\hat{G_{a}}^{(c)}(\omega=\sigma_{\omega}^{(a)}) . In particular, for the Radon Fourier transform in the s scan, the main signal crucial for the resolution is measured at s=\sigma_{w}^{(a)} , where \frac{\Delta P_{2b}}{P_{2b}}=C_{a}\frac{\Delta P_{2b}^{(a)}}{P_{2b}^{(a)}} , according to Eq.( 13 ). Thus, the achievable resolution is determined by the amplitude of TPPF at \sigma_{\omega}^{(a)} . \frac{\Delta P_{2b}}{P_{2b}}=C_{a}\frac{\Delta P_{2b}^{(a)}}{P_{2b}^{(a)}} and P_{2b}=\frac{c_{a}}{C_{a}}P_{2b}^{(a)} expressed the photon counting number and its variation of the cascaded double slit in terms of a single idealized slit. This derivation shows that the cascaded double slit acts as a spatial frequency filter, the 2nm slit allows critically important high frequency components to reach the beam waist at x=\sigma_{w} while cutting off the lower frequency components. The 10nm slit allows the low frequency component near the center to pass through to the detector while suppressing them to low intensity outside the 10nm slit, and hence lowers the low frequency components, which if not cutoff, would increase the total detected photon number and the shot noise, and degrade the resolution mainly determined by high frequency components. 4.2 The counting number and its relation to the measurement signal-to-noise ratio at the width \sigma_{w}^{(a)} of TPPF of resolution 3.3nm For a single slit of width \sigma_{a} and with idealized thickness, in Section 2.4 we find the signal-to-noise ratio (SNR) is S_{na}\equiv\frac{\Delta N_{2a}(x=\sigma_{w}^{(a)})}{\delta N_{2a}}=37 . To derive the SNR for the double slit in the following, we denote the parameters of the idealized single slit by subscript a to distinguish them from the parameters for the cascaded double slit. For a cascaded double slit instead of a single slit a , apply the result of the last section P_{2b}=\frac{c_{a}}{C_{a}}P_{2b}^{(a)} and \frac{\Delta P_{2b}(x=\sigma_{w}^{(a)})}{P_{2b}}\approx C_{a}\frac{\Delta P_{2b}^{(a)}(x=\sigma_{w}^{(a)})}{P_{2b}^{(a)}} to Eq.( 11 ), we find S_{n}=\frac{\Delta N_{2}(x=\sigma_{w}^{(a)})}{\delta N_{2}}=\sqrt{N_{1}P_{2b}}\frac{\Delta P_{2b}(x=\sigma_{w}^{(a)})}{P_{2b}} =\sqrt{N_{1}\frac{c_{a}}{C_{a}}P_{2b}^{(a)}}C_{a}\frac{\Delta P_{2b}^{(a)}(x=\sigma_{w}^{(a)})}{P_{2b}^{(a)}} . If we keep N_{1}=N_{1a}, then S_{n} =\sqrt{c_{a}C_{a}}S_{na} . Since c_{a}C_{a}<1 , the SNR for the cascaded double is smaller than the idealized single slit. If we choose N_{1}=\frac{1}{c_{a}C_{a}}N_{1a} , then the SNR is recovered to S_{n}=S_{na} . As a result N_{2} increases by a factor \frac{1}{C_{a}^{2}} , while \delta N_{2} and \Delta N_{2}(x=\sigma_{w}^{(a)}) both increase by a factor \frac{1}{C_{a}} compared with the idealized single slit a , to keep \Delta N_{2}(x=\sigma_{w}^{(a)})/\delta N_{2} unchanged. For the parameters in Fig. 4 at 2.29kev, with the cascaded double slit in Fig. 8 ( c_{a}=0.842 , C_{a}=\frac{c_{a}\sqrt{2\pi}\sigma_{a}}{c_{a}\sqrt{2\pi}\sigma_{a}+c_{b}\sqrt{2\pi}\sigma_{b}}=\frac{0.842\times 2nm}{0.842\times 2nm+0.8158\times 10nm}=0.516 ), \sqrt{c_{a}C_{a}}=0.66 . Thus, SNR becomes 0.66\times 37\approx 24. If the input photon number remains as 2.15\times 10^{9} . To recover to SNR=37 we need to increase by a factor 1/(c_{a}C_{a})=2.27 to 4.9\times 10^{9} . 4.3 Assessment of 3.3 nm Resolution and SNR=37 when the requirement on the slit thickness is reduced from 400nm to 150nm for a cascated triple slit If we prefer using the existing example in ref. nm_cm_slit to produce a 2nm wide 150nm thick slit instead of the 400nm thick example in the cascaded double slit , we consider using the 150nm slit combined with another two slits aligned together. The extension of the discussion of the cascaded double slit in Sections 4.1 and 4.2 to a cascaded triple slit is straightforward. We consider a 2nm wide 150nm slit, a 4nm wide 300nm slit aligned with a 10nm wide 2\mu m slit. Following the same way as 4.1, the first slit attenuates to 50%, c_{a}=1-0.5=0.5 , the second slit, further from 0.5 attenuates to c_{c}=0.25*0.5=0.125 , so c_{b}=0.5-0.125=0.375 . Then, outside slit b, the transmission drops from 0.125 to nearly zero. Thus, the transmission drops from 1 to 0.5 to 0.125 to zero in 3 steps as x_{2} moves away from the center. Hence, the cascaded triple slit function is f_{2}^{2}(x_{2})=c_{a}f_{2}^{2}(x_{2},\sigma_{a})+c_{b}f_{2}^{2}(x_{2},\sigma_{b})+c_{c}f_{2}^{2}(x_{2},\sigma_{c}) . Again, we have P_{2b}=\frac{c_{a}}{C_{a}}P_{2b}^{(a)} . Since the TPPF width and the bandwidth of the slit b and c are smaller than a , we can choose cut off at x=\sigma_{w}^{(a)} to reach the bandwidth given by the slit a , and we have \frac{\Delta P_{2b}(x=\sigma_{w}^{(a)})}{P_{2b}}\approx C_{a}\frac{\Delta P_{2b}^{(a)}(x=\sigma_{w}^{(a)})}{P_{2b}^{(a)}} again except now C_{a}=\frac{c_{a}\sigma_{a}}{c_{a}\sigma_{a}+c_{b}\sigma_{b}+c_{c}\sigma_{c}}=0.267 , and, \frac{1}{c_{a}C_{a}}=7.5 . Now following the same steps as 4.2, the error bar increases from 2.7\% to 7.4\% by the factor \sqrt{\frac{1}{c_{a}C_{a}}}=2.74 when the cascaded triple slit is used. To recover the error bar due to the shot noise back to 2.7\%, we need to increase the photon number at slit 1 from N_{1}=2.1\times 10^{9} to 16\times 10^{9} by the factor \frac{1}{c_{a}C_{a}}=7.5 . Therefore, given a realistic noise floor 2.7%, the 3.3 nm resolution is likely achievable if the sample has enough Fourier strength at that frequency. If other sources of noise is much less than 2.7%, and if the signal in the sample is less, it might be nessesary to increase the photon number at slit 1. On the other hand, if the signal is larger than 2.7%, the photon number required may be reduced. 5. Picometer X-ray Displacement Sensing via Two-Point Propagation Field With the cascaded double-triple slit calculation ready, our next step to develop TPPF-based tomography is to analyze the feasibility of replacing the 50-line comb made of 50 pins of 3nm width, preferably and more practically, by a single \sim 15-25\,nm -thick gold film patterned with 50 lines of 6.7\,nm period, operated at x\approx 40\mu m . The discussion on the cascaded double-triple slit in Section 4, indicated the feasibility of such a comb as a sample using the technology in refs. cfn_nano ; cfn_jove ; nm_cm_slit . We apply the formula developed in sections 2,3,4 to provide the first step of testing the TPPF and its connection with tomography to show that the gold film pattern can be used as a lensless picometer x-ray displacement sensor. Detection rate variation of the gold film pattern. We assume a modulation depth of 10nm, the modulated attenuation depth estimated using the gold \mu/\rho given in Section 4 is m_{gold}=0.023, Since the gold film sample width \Delta x=330nm\ll\sigma_{w} , the gold film attenuation is \Delta\chi(x-x_{p})=m_{gold}\cos(kx-kx_{p}) , and \frac{1}{P_{2b}}\frac{\delta P_{2b}}{\delta\chi(x,y,z)}\approx m_{TPPF}\cos(kx+\phi) , given as m_{TPPF}=2.3\times 10^{6}m^{-1} in Section 2.4, we have \frac{\Delta P_{2b}}{P_{2b}}\approx\frac{1}{P_{2b}}\frac{\delta P_{2b}}{\delta\chi(x,y,z)}\Delta\chi(x-x_{p})\Delta x\approx\frac{1}{2}m_{TPPF}m_{gold}\cos\left(kx_{p}-\phi\right)\Delta x , ignoring the term with a fast oscilating phase 2kx . Thus, when we move the gold film x_{p} by 3.35nm, the peak to peak variation is |\frac{\Delta P_{2b}}{P_{2b}}|_{p}=m_{TPPF}m_{gold}\Delta x\approx 0.0175 . The incident photon number N_{1a} required to achieve 15 pm sensitivity for an idealized slit 2 with photon counting N_{2a} . The detection probability is P_{2b}=1.86\times 10^{-5} in our example (see Fig. 4 ). Assume the photon counting number N_{2a}=4\times 10^{6} at the detector behind the slit 2, the RMS shot noise is \delta N_{2a}=\sqrt{N_{2a}}=2000 , when we move the gold film pattern x_{p} , the photon counting variation is \Delta N_{2a}=|\frac{\Delta P_{2b}(s)}{P_{2b}}|_{p}N_{2a}=0.0175\times 4\times 10^{6} =7\times 10^{4} . Thus the signal noise ratio is \frac{\Delta N_{2a}}{\delta N_{2a}}=|\frac{\Delta P_{2b}(s)}{P_{2b}}|_{p}\sqrt{N_{2a}} =0.0175\times\sqrt{4\times 10^{6}}=35 . From the discussion above, the photon counting signal is \Delta N_{2a}=N_{2a}|\frac{\Delta P_{2b}}{P_{2b}}|_{p}\cos\left(kx_{p}-\phi_{1}\right) . Then shot-noise-limited displacement sensitivity follows directly from Poisson statistics of the detected photons, the sensitivity is \delta x_{p}=\frac{\delta N_{2a}}{kN_{2a}|\frac{\Delta P_{2b}}{P_{2b}}|_{p}}=\frac{\lambda_{fringe}}{2\pi\sqrt{N_{2a}}|\frac{\Delta P_{2b}}{P_{2b}}|_{p}}=\frac{6.7nm}{2\pi\sqrt{4\times 10^{6}}\times 0.0175}=15pm . The incident photon number at the entrance slit 1 when the slit 2 is idealized is N_{1a}=\frac{N_{2a}}{P_{2b}}=\frac{4\times 10^{6}}{1.86\times 10^{-5}}\approx 2.15\times 10^{11} . Then for a possible cascaded double-triple slit, we calculate for the following 4 options. 5.1 Cascaded Double slit with first slit 2nm wide 400nm thick. We apply the analysis of the cascaded double slit in Setions 4.2 and 4.3. The example of ALD gold on SiN membranes in reference nm_cm_slit is a 2nm wide, 150 nm thick, and 2 cm long slit. We first consider an option of a possible \sqrt{2\pi}\sigma_{a}=2 nm wide 400 nm depth first slit followed by a \sqrt{2\pi}\sigma_{b}=10nm wide 2 \mu m depth slit. The first slit a suppresses the intensity to c_{b}=0.158 right before the second slit b, then the latter further suppresses the intensity to \ll 10^{-4} and can be ignored. Thus, the slit a contributes to the transmission by c_{a}=1-c_{b}=0.842 . The TPPF for the 2nm wide slit given Eq.( 8 ) as a function of x, is dominated by a simple factor \exp(\alpha_{\chi r}x^{2})=\exp(\alpha_{\chi r}x^{2})\exp(i\alpha_{\chi i}x^{2}) , where \alpha_{\chi}=\alpha_{\chi r}+i\alpha_{\chi i} is a complex valued parameter with |\alpha_{\chi i}|\gg|\alpha_{\chi r}| and \alpha_{\chi r}<0 (see Sec. 2.3). The factor \exp(i\alpha_{\chi i}x^{2}) results in a chirp of high spatial frequency k_{x}=2\alpha_{\chi i}x linearly increasing with x , while the amplitude of TPPF slowly drops according to a factor \exp(\alpha_{\chi r}x^{2}) . At the beam waist x=\sigma_{w}\approx 40\mu m , \exp(\alpha_{\chi r}x^{2})=\exp(-1/2)\approx 0.6 , and k_{\sigma_{w}}=2\pi/\lambda_{fringe} with \lambda_{fringe}=6.7nm . The width of the TPPF for the 10 nm slit b has much smaller angular spread, i.e., its width in x is smaller and its contribution dominates the region of x\ll\sigma_{w}=40\mu m , while its contribution at x=\sigma_{w}\approx 40\mu m is negligible. Thus, TPPF near x=40\mu m is dominated by the TPPF of slit a, so it remains as if there is only slit a. The combined effect of the cascaded double slit is that TPPF for low spatial frequency k_{x} increased while at x=40\mu m remains the same. This gives the quantitative analysis of the cascaded double slit in Section 4.1 a qualitative interpretation. The analysis in Section 4.1 shows when the cascaded double slit replace the single idealized slit a, because the low spatial frequency component increased, the shot noise increased, the signal noise ratio becomes SNR=\frac{\Delta N_{2}}{\delta N_{2}}=\sqrt{c_{a}C_{a}}\frac{\Delta N_{2a}}{\delta N_{2a}} , where C_{a}\equiv\frac{c_{a}\sigma_{a}}{c_{a}\sigma_{a}+c_{b}\sigma_{b}}=\frac{0.842\times 2nm}{0.842\times 2nm+0.158\times 10nm}=0.516 . \frac{\Delta N_{2a}}{\delta N_{2a}} is the SNR when there is only one idealized slit a. Thus, for the cascaded double slit SNR =\sqrt{0.842\times 0.516}\times 35=23 . The derivation in 4.2 shows , to recover the SNR back to 35 , thus also recover the position sensitivity back to 15pm, we need to increase the incident photon number to N_{1}=\frac{1}{c_{a}C_{a}}N_{1a}=\frac{1}{0.842\times 0.516}\times 2.15\times 10^{11}=4.9\times 10^{11} . 5.2 Cascaded Triple slit with first slit 2nm wide, 150nm thick. Assume we apply the technique based on the existing example in nm_cm_slit , we generalize the cascaded double slit to a cascaded triple slit. We consider a cascaded triple slit TPPF for 2.29 keV case (0.541nm case), (a) 2nm wide,150nm thick,(b) 4nm wide, 300nm thick,(c) 10nm wide, 2 \mu m thick. The performance calculation using the formula in 4.1 is almost the same as the cascaded double slit. Using the same gold \mu/\rho and the formula in 4.2, the first slit a attenuates to 50%, c_{b}=1-0.5=0.5 , the second slit b, further from 0.5 attenuates to 0.25*0.5=0.125 before the slit c, so c_{b}=0.5-0.125=0.375 . Then, outside slit c, the transmission drops from 0.125 to nearly zero ( \sim 1.2\times 10^{-5}) . Thus, we find with c_{a}=0.5,\sqrt{2\pi}\sigma_{a}=2nm,c_{b}=0.375,\sqrt{2\pi}\sigma_{b}=4nm, c_{c}=0.125,\sqrt{2\pi}\sigma_{b}=10nm . C_{a}\equiv\frac{c_{a}\sigma_{a}}{c_{a}\sigma_{a}+c_{b}\sigma_{b}+c_{c}\sigma_{c}}=0.267 , c_{a}C_{a}=0.133 . To recover the increased signal noise ratio back to 35, and 15pm sensitivity, we need to increase the incident photon number to N_{1}=\frac{N_{1a}}{c_{a}C_{a}}=\frac{2.15\times 10^{11}}{0.133}=1.6\times 10^{12} . 5.3 Cascaded Triple slit with first slit 4nm wide, 300nm thick. If we would like to avoid using the most advanced technology as prescribed in nm_cm_slit , a more robust 4 nm first slit gives identical performance at \sim 2.8\times 10^{12} photons but uses the same aspect ratio for the slit. We consider a cascaded triple slit consisting of 3 slits: (a) 4nm wide, 300nm thick,(b) 10nm wide, 750nm thick,(c) 20nm wide, 1.5 \mu m thick. For \sqrt{2\pi}\sigma_{2}=4 nm, we find \alpha_{\chi i} (See Appendix III) remains the same, so at x\approx 40\mu m , the fringe spacing \lambda_{fringe}=6.7nm remains the same, while \alpha_{\chi r} increased by a factor 2.68, thus the amplitude factor \exp(\alpha_{\chi r}x^{2}) drops from \exp(-1/2)=0.6 to \exp(-1/2\times 2.68)=0.261 . Thus, the amplitude drops by a factor \frac{0.6}{0.261}=2.3 . To achieve the same precision, we need to increase the photon number by a factor 2.3^{2}\approx 5.3 . For the cascaded triplet now with the first 4nm wide slit a has c_{a}C_{a}=0.749\times 0.536=0.40 . Thus, we need to increase the incident photon number to N_{1}=\frac{N_{1a}}{c_{a}C_{a}}=\frac{5.3\times 2.15\times 10^{11}}{0.4}=2.8\times 10^{12} for the same precision of 15pm. 5.4 Cascaded Triple slit with first slit 2nm wide, 150nm thick, and the gold film pattern at x=80\mu m to achieve sensitivity at 7.5pm. To improve the sensitivity to displacement further down to 7.5 pm we consider still using the cascaded triple slit with a first 2 nm wide 150nm thick slit. We need to double the position of the gold film pattern from 40\mu m to x=80\mu m . Since the only change is x in the dominating factor \exp(i\alpha_{\chi i}x^{2}) of the TPPF , the frequency k_{x}=2\alpha_{\chi i}x becomes k_{x}=2\pi/\lambda_{fringe} with fringe spacing halved to \lambda_{fringe}=3.35nm , but the ampltude factor drops from \exp(\alpha_{\chi r}\sigma_{w}^{2})=\exp(-1/2)\approx 0.6 in section 3.1 to \exp(\alpha_{\chi r}4\sigma_{w}^{2})=\exp(-2)\approx 0.135 by a ratio 0.6/0.135=4.4 . Thus, to recover to the same signal noise ratio, we need to increase the incident photon number by the ratio squared to N_{1}=\frac{4.4^{2}N_{1a}}{c_{a}C_{a}}=\frac{4.4^{2}\times 2.15\times 10^{11}}{0.133}\approx 3.1\times 10^{13} . In short, we considered 4 possible options for the slit 2: (1) A cascaded double slit with first 2 nm wide 400nm thick slit need incident photon number N_{1}=4.9\times 10^{11} to reach sensitivity of 15pm for the idealized single 2nm slit a. (2) A cascaded double slit with first 2 nm wide 150nm thick slit: N_{1}=1.6\times 10^{12} , 15pm senstivity. (3) A cascaded triple slit with a first 4 nm wide 300nm thick slit: N_{1}=2.8\times 10^{12} , 15pm sensitivity. (4) A cascaded double slit with a first 2 nm wide 150nm thick slit: N_{1}=3.1\times 10^{13} for 7.5pm sensitivity. We note that, in our example, the displacement sensitivity is \delta x\approx 15pm , while the photon’s momentum spread is bounded by \delta p\leq h/\lambda (with \lambda=0.541 nm). This yields \delta x\delta p<15 pm \times h/0.541 nm \approx 0.026h . Compared to the Heisenberg uncertainty relation \Delta x\Delta p\geq h/4\pi\approx 0.08h , we have \delta x\delta p\lesssim(1/3)(\Delta x\Delta p) . Since \delta x represents the relative movement of the macroscopic gold film pattern with respect to the TPPF structure—rather than a direct measurement of the photon’s position—this result is consistent with the uncertainty principle and poses no violation. 5.5 The Broadening from Finite X-ray beam bandwidth \frac{\Delta E}{E} The calculations assume a monochromatic beam. For finite bandwidth, by Eq.( 10 ), the TPPF phase \phi=\alpha_{\chi i}x^{2}\approx\frac{\pi x^{2}}{\lambda L(1-\xi)} shifts relatively as \frac{\delta\phi}{\phi}=-\frac{\delta\lambda}{\lambda} . To compensate this shift (maintain constant phase at fixed x ), a displacement \delta x=\frac{x}{2}\frac{\delta\lambda}{\lambda} is required. At the beam waist x=\sigma_{w}\approx 40\,\mu m and \frac{\delta\lambda}{\lambda}=10^{-5} , this yields \delta x\approx 200 pm. Optionally, to match the shot-noise-limited sensitivity to this broadening (rather than 15 pm), the required incident photons N_{1a}\approx 2.15\times 10^{11} are reduced by a factor \left(\frac{200\,\text{pm}}{15\,\text{pm}}\right)^{2}\approx 178 , to N_{1a}\approx 1.2\times 10^{9} . Correspondingly the flux required in the 4 options above, is also reduced by the same factor. Practical grating monochromators achieve \Delta E/E\approx 10^{-5} ; ultra-high-resolution optics can approach lower values. 6 Prospective Flux Reduction via Central Spatial-Frequency Filtering and Multiple Detector Slit Option and Their Influence on the Development of Lensless X-ray Picometer and Radon Fourier Transform Based X-ray Micro-tomography The TPPF at |x| \approx 40 µm has a high spatial frequency (\lambda_{fringe}\approx 6.7nm ). Photons propagating near x\approx 0 contribute negligibly to the sinusoidal signal at 6.7nm but dominate the total detected counting number N{{}_{2}} and thus the shot noise. A micron-scale opaque blocker placed centrally 0.4mm before slit 2 is expected to suppress this useless background by >90 % while leaving the signal-carrying high-frequency component nearly untouched. A preliminary estimate suggests the required N{{}_{1}} could drop below 10{{}^{1}}{{}^{0}}\text{\textendash}10{{}^{1}}{{}^{1}} photons for 15 pm sensitivity — a >10\text{\textendash}100\times improvement in speed and dose. Full wave-optical calculation is in progress. Another, potentially far more powerful flux-reduction strategy is to use a two-dimensional array of many detection slits displaced from the optical axis ( s_{2}\neq 0 in Fig. 1). Because the TPPF fringes at different off-axis positions are laterally shifted, their intensity modulations add incoherently when summed: the total signal scales linearly with the number of slits N_{slit} , while shot noise scales only as \sqrt{N_{slit}} . A moderate 2-D array of N_{slit}=10^{3} detection channels — readily achievable in the near term by fabricating arrays of triple-slit cascades with 20–50 µm pitch over a few-millimetre detector area — is estimated to reduce the required incident fluence by an additional two orders of magnitude. Larger custom arrays ( N_{slit} \gtrsim 10{{}^{4}}) , which would also eliminate mechanical scanning and enable instantaneous picometer readout with extremely low radiation dose for biological samples, appear feasible with continuing advances in nanofabricated multi-slit technology. So far for simplicity, we only consider a single slit 2 at x=s_{2}=0 , while Eq.( 8 ) the analytical expression of TPPF already gives the option of s_{2}\neq 0 . Depends on the technology available for the separate slit 2 at another location, such as s_{2}=1\mu m , we may consider a slit array to simultaneously record the counting rate for other sample positions and hence for other spatial frequencies without increasing the incident photons. This option requires revising the TPPF-Radon Fourier transform relation Eq.( 13 ), to increase a variable s_{2} in g(s),G^{(c)}(x) to g(s,s_{2}),G^{(c)}(x,s_{2}) , with a remark that s here is the position of the sample relative to x , while s_{2} is the position of slit 2. In principle, this would not change the formulation of TPPF-Radon Fourier transform relation, except it increases the matrix dimension in the reconstruction program, also extends the calibration of TPPF from s_{2}=0 , to a calibration of TPPF for various s_{2} . However, this does not increase the time the calibration takes because all these various s_{2} calibration can be done simultaneously with s_{2}=0 . A single photon detection can at most be in one of these slits 2, and for the multiple slits 2, each can only record the photons statistics at its position with the corresponding spatial frequency and phase, however their accumulation of data is simultaneous, so the total statiscs of the slit array will be increased proportionaly by a factor of 100 or more to significantly reduce the required scan points in the Radon scan if it is possible to minimize the spacing of the slit to the order of 1 \mu m . If the array of slits 2 also includes different y position of slits 2, then even the number of Radon scans in y -direction can be reduced too. Hence, their impact on reducing the flux and radiation damage will be expected to be significant. Another remark is the gold film attenuation introduced \Delta\chi(x-x_{p})=m_{gold}\cos(kx-kx_{p}) , where m_{gold} can be replaced in tomography by the Fouier expansion coefficient m_{sample} at a specified wavelength \lambda_{fringe} , and the formula can be used to estmate the required incident photon number to achive a desired resolution, just as our analysis in Section 5 for the x-ray picometer sensor. Both posibility can provide significant flux reduction for the x-ray picometer sensor, and for further improve of the lensless x-ray-tomography, in particular, it will reduce the flux requirement and hence reduce the radiation damage to the sample due to those photons reaching the sample, which is only a small fraction of the incident photon number. This reduction may have a significant impact on the application of tomography of biomolecular samples. 7. Relation To Quantum Measurement During the Free Space Propagation Between the Source and Detector Slit The TPPF concept originates from a perturbative study of single-particle propagation and measurement yu-1 . The consideration and interpretation of the following questions about this measurement problem led to the TPPF concept. This then turns to the X-ray picometer displacement sensor and the connection to tomography. We first discuss the system in Fig. 1 with \Delta\chi(x)=0 because the following fundamental question in quantum mechanics. The wave function of a single particle starting from the entrance slit becomes wide-spread before it strikes the screen with the exit slit, as shown in Fig 1(b). Most times, it is not detected, but there is a fixed probability that it is detected. And in the instant of the detection, the wave function collapses into the slit with energy h\nu . We understand there is no contradiction with relativity here because the wave function is only a probability amplitude, after the detection our knowledge changes from a probability distribution of the particle to a point. However, there is a question about whether and how the associated energy distribution of h\nu also collapses. Whatever happens, the energy h\nu becomes concentrated in the detector when detected. Experimental investigation is difficult because any intermediate measurement between the source and detection slits either collapses the wave function or substantially alters it. Even in a weak measurement, for example, as discussed in an overview weak_WIKI , the wave function is significantly altered. In the example ahanorov , it is caused by magnets, in the case of ludeen ; kocsis , it is caused by lenses. To seek an answer for this question, in Fig. 1 (a), we study the effect of a perturbation \Delta\chi(x) on the counting rate P_{2b}=\int_{-\infty}^{\infty}dx_{2}|\psi_{2b}(x_{2})|^{2} , and calculate the ratio of the counting rate change over the perturbation. As the perturbation approaches zero, the ratio \frac{\Delta P_{2b}}{\Delta\chi(x,z)} becomes the functional derivative \frac{\delta P_{2b}}{\delta\chi(x,z)} of the counting rate over the perturbation \Delta\chi(x) . This perturbative function is independent of perturbation. It is a real-valued function containing high-resolution phase information, determined solely by the two-slit geometry in our 2D study as we show in the Fig. 2 . It can be measured with high precision and reproducibility, it uniquely characterizes the individual event of a particle propagating between the two slits. Unlike a probability amplitude, it manifests as a stable, reproducible structure that we interpret as consistent with an objectively existing field, which we define as the two-point propagation field (TPPF). The TPPF does not correspond to a probability distribution. While the wave function describes an ensemble of possible detection outcomes, the TPPF characterizes the process underlying a single detection — a realization selected according to the Born rule. While these interpretative aspects remain speculative, experimental validation of the TPPF through picometer sensing could provide empirical insights into such foundational questions 8. Conclusion The analysis based on the TPPF and the cascaded triple slit estimation provides, (1) An experimental test basis for TPPF as a detailed wavefunction collapse process where fine fringes, without lens or focusing, continuously converge to the 2 nm slit and confirm that TPPF turns the wave function into a measurable observable with 15 pm displacement precision, while a measurement of the wave function absolute square, as a probability density, lost the phase information in the propagation. (2) A direct feasibility study of a practical tool to stabilize the displacement between the x-ray beam and the sample, as one of the main goals of this work. The tool itself can be very useful for tomography applications, because the motion between the x-ray beam and the sample of order of 4 nm is one ot the limitations of tomography resolution swiss_tomography_4nm . And (3) provide a direct calibration of TPPF function \frac{1}{P_{2b}}\frac{\delta P_{2b}^{(c)}}{\delta\chi(x,z)} in Eq.( 12 ) for various spatial wavelengths obtained by various orientations of the gold film pattern. As we discussed in Section 3.1, this function is the basis of the Radon Fourier transform to be used for the tomography, and we should use this experimentally calibrated function rather than the theoretical function of Eq. ( 8 ) because this would remove the systematic error between the experimental setup and the theoretical model. (4). It also bridges between the TPPF experimental confirmation and nanometer x-ray micro-tomography, and provides a basis for a more detailed study in this direction, from the Radon scan to the photon number required to achieve the resolution. (5) The example here is not optimized for tomography because the parameters such as \lambda,L-z,\sigma_{1},\sigma_{2},x have large room for variation, depending on sample mass attenuation coefficients, sample’s attenuation Fourier expansion coefficients, damage threshold, prior knowledge for reconstruction of tomography, etc. This justifies engaging in discussions with X-ray tomography experts to develop simulations that test the new lensless method and determine the best achievable resolution. For example, we can reduce the incident photon number at the expense of lower precision. Here we provide a simple analytical tool to help with the assessment. Hence, the picometer X-ray displacement Sensing via TPPF, in addition to its direct application in X-ray tomography, is also a stepping stone for the exploration of its application in a new method in X-ray tomography bassed on Radon Fourier transform. This becomes clearer when we consider the ongoing study discussed in Section 6 to significantly reduce the photon flux. The TPPF bears analogy to Green’s functions or propagators, offering a real-valued, measurable correlate to complex amplitudes, potentially extensible to high-energy contexts. We thank Dr. T. Shaftan, and Dr. V. Smaluk for their discussion and suggestions on the manuscript. Appendix I Hilbert Transform For a real function with Fourier exanpsion u(t)=\Sigma_{-n}^{n}a_{n}e^{i\omega_{n}t} , its Hilbert transform is H(u)(t)=\Sigma_{-n}^{n}b_{n}e^{i\omega_{n}t} such that for terms with \omega_{n}>0 , b_{n}=-ic_{n} , for terms with \omega_{n}<0 , b_{n}=ic_{n} , for terms with \omega_{n}=0 , b_{n}=0 . Then f(t)=u(t)+iH(u)(t) is an analytical function. The real part of f(t) is u (t), its imaginary part is H(u)(t) . Thus, once we have u(t) we can calculate its amplitude and phase from f(t) using The Hilbert transform. Appendix II Analytic TPPF \frac{\delta P_{2b}^{(c)}}{\delta\chi(x,z)} Expressed by \alpha_{\chi} and P_{2b} The complex TPPF \frac{\delta P_{2b}^{(c)}}{\delta\chi(x,z)} in Eq.( 6 ) is a triple Gaussian integral over three variables x_{1},x_{2},x^{\prime}_{1} , each of which can be integrated by the formula \int dx\exp\left(ax^{2}+bx+c\right)=\left(\frac{\pi}{-a}\right)^{\frac{1}{2}}\exp\left(-\frac{b^{2}}{4a}+c\right)=\exp\left(-\frac{b^{2}}{4a}+c+\ln\left(\frac{\pi}{-a}\right)^{\frac{1}{2}}\right), (16) The integral over x^{\prime}_{1} result is expressed by the parameters \mu,\rho,\xi defind before Eq.( 8 ) in Section 2.2 in terms of the basic parameters in the setup in Fig.1: \sigma_{1},\sigma_{2},\lambda,k,L , and z , \displaystyle\frac{\delta P_{2b}^{(c)}}{\delta\chi(x,z)}=\left(\frac{1}{2\pi^{3}\sigma_{1}^{2}(1-\xi)\xi\left(1-\frac{i}{\mu}\right)}\right)^{\frac{1}{2}}\left(\frac{ik}{2L}\right)\int_{-\infty}^{\infty}dx_{2}\int_{-\infty}^{\infty}dx_{1}\exp\left[\frac{ik}{2L}f(x_{1},x_{2})\right] (17) \displaystyle f(x_{1},x_{2})=A_{1}(x_{1}-\frac{B_{1}}{A_{1}})^{2}+A_{2}(x_{2}-\frac{B_{2}}{A_{2}})^{2}+C where A_{1},B_{1},A_{2},B_{2},C are expressed in term of the basic parameters, A_{1},A_{2} are independent of x,s_{1},s_{2} the variable indicated in Fig.1, while B_{1},B_{2} are linear in x,s_{1},s_{2} , C is a quadratic polynomial of x,s_{1},s_{2} . The integral over x_{1},x_{2} in Eq.( 17 ) then carried out as a Gaussian integral by Eq.( 16 ), the result is \displaystyle\frac{\delta P_{2b}^{(c)}}{\delta\chi(x,y,z)}=\left(\frac{1}{2\pi\sigma_{1}^{2}(1-\xi)\xi\left(1-\frac{i}{\mu}\right)}\frac{1}{A_{1}A_{2}}\right)^{\frac{1}{2}}\exp\left[\frac{ik}{2L}a(x-b)^{2}+\frac{ik}{2L}D\right] (18) \displaystyle A_{1}=\frac{1}{\xi}+\frac{i}{\mu},A_{2}=\frac{1}{1-\xi}+\frac{2i}{\rho\mu}-1+\frac{1}{1-\frac{i}{\mu}}, \displaystyle a=\left(\frac{1}{(1-\xi)}+\frac{1}{\xi}\right)-\left(\frac{1}{A_{1}}\frac{1}{\xi^{2}}+\frac{1}{A_{2}}\frac{1}{\left(1-\xi\right)^{2}}\right) \displaystyle b=\frac{1}{a}\left(\frac{b_{1}}{A_{1}}\frac{1}{\xi}+\frac{b_{2}}{A_{2}}\frac{1}{1-\xi}\right) \displaystyle b_{1}=\frac{is_{1}}{\mu},b_{2}=\frac{2is_{2}}{\rho\mu}+\frac{i\frac{s_{1}}{\mu}}{1-\frac{i}{\mu}} \displaystyle D=C(x=0)-ab^{2} \displaystyle C(x=0)=\frac{2i}{\rho\mu}(s_{2})^{2}+\frac{2i}{\mu}s_{1}^{2}-\frac{1}{\mu^{2}\left(1-\frac{i}{\mu}\right)}s_{1}^{2}-\left(\frac{\left(\frac{is_{1}}{\mu}\right)^{2}}{A_{1}}+\frac{\left(\frac{2is_{2}}{\rho\mu}+\frac{i\frac{s_{1}}{\mu}}{1-\frac{i}{\mu}}\right)^{2}}{A_{2}}\right) Since P_{2b}=\frac{1}{2}\int_{-\infty}^{\infty}dx\frac{\delta P_{2b}}{\delta\chi(x,z)}=\int_{-\infty}^{\infty}dx\frac{\delta P_{2b}^{(c)}}{\delta\chi(x,z)} is independent of z , we use this to simplify the calculation of \frac{\delta P_{2b}^{(c)}}{\delta\chi(x,y,z)}, and find \displaystyle P_{2b}=\int dx\frac{\delta P_{2b}^{(c)}}{\delta\chi(x,y,z)}=\left(\frac{1}{-2\sigma_{1}^{2}(1-\xi)\xi\left(1-\frac{i}{\mu}\right)\frac{ik}{2L}aA_{1}A_{2}}\right)^{\frac{1}{2}}\exp\left[\frac{ik}{2L}D\right] Now compare this with P_{2b}=\sqrt{\frac{\mu^{2}\rho}{\mu^{2}+\rho\mu^{2}+1}}\exp\left(-\frac{1}{2\sigma_{1}^{2}}{\displaystyle\frac{\mu^{2}}{\mu^{2}+1+\mu^{2}\rho}}(s_{1}-s_{2})^{2}\right) derived as Eq.(10) of refs. yu-1 , we can simplify the two complicated expressions. Compared with the coefficient and the exponent of P_{2b} , we find the following relation, \displaystyle(1-\xi)\xi\left(1-\frac{i}{\mu}\right)\frac{ik}{2L}aA_{1}A_{2}=\frac{\mu^{2}+\rho\mu^{2}+1}{-2\sigma_{1}^{2}\mu^{2}\rho}. (19) Applying this relation, the complex TPPF in Eq.( 18 ) is simplified as an exponential function expressed by a parameter \alpha_{\chi} that determines the peak, width and spatial frequency distribution of TPPF, \displaystyle\frac{\delta P_{2b}^{(c)}}{\delta\chi(x,z)}=P_{2b}\sqrt{\frac{-\frac{ik}{2L}a}{\pi}}\exp\left[\frac{ik}{2L}a(x-b)^{2}\right]=P_{2b}\sqrt{\frac{-\alpha_{\chi}}{\pi}}\exp\left[\alpha_{\chi}(x-x_{c})^{2}\right] \displaystyle\alpha_{\chi}=-\frac{i\mu\left(\mu^{2}+\rho\mu^{2}+1\right)}{2\sigma_{1}^{2}\left(-i\mu+\xi\right)\left(2(\xi-1)\left(\mu i+1\right)+\mu\left(i\xi-\mu\right)\rho\right)} Now with 2k\sigma_{1}^{2}=\mu L , use the relation Eq.( 19 ), we find x_{c} , \displaystyle x_{c}=\frac{{\displaystyle c_{S1}}s_{1}+{\displaystyle c_{S2}}s_{2}}{{\displaystyle\mu^{2}+\rho\mu^{2}+1}} \displaystyle{\displaystyle c_{S1}}\equiv{\displaystyle\rho\mu^{2}-\left(i\mu+1\right)}\left(\xi-1\right),{\displaystyle c_{S2}}\equiv{\displaystyle\left(\mu-i\right)\left(\mu+i\xi\right)} (20) Appendix III Approximation of \alpha_{\chi} , P_{2b} Near Narrow Slit \sigma_{2} The formula Eq.( 8 ) for \alpha_{\chi} is not complicated. But the order of magnitude estimation of \alpha_{\chi r},\alpha_{\chi i} , \text{Re}{\displaystyle\left(\frac{1}{\alpha_{\chi}}\right)} , and \text{Im}\left(\frac{1}{\alpha_{\chi}}\right) in its small slit size limit \mu=\frac{4\pi\sigma_{1}^{2}}{\lambda L}\ll 1 , \rho=\frac{\sigma_{2}^{2}}{\sigma_{1}^{2}}\ll 1 is simpler, in particular when close to slit 2 when , as in the 3D tomography study: \displaystyle\alpha_{\chi i}\approx-\frac{\mu}{4\sigma_{1}^{2}}\frac{{\displaystyle 1}}{{\displaystyle\xi\left(\xi-1\right)}}\approx\frac{\pi}{\lambda L}\frac{{\displaystyle 1}}{{\displaystyle 1-\xi}} \displaystyle\alpha_{\chi r}\approx-\frac{\mu^{2}}{4\sigma_{1}^{2}}\frac{{\displaystyle\left(\rho\xi^{2}+2(\xi-1)^{2}\right)}}{{\displaystyle 2\xi^{2}\left(\xi-1\right)}^{2}}\approx-\left(\frac{\pi}{\lambda L}2\sigma_{1}\right)^{2}\left(1+\frac{\rho}{{\displaystyle 2\left(\xi-1\right)}^{2}}\right) \displaystyle\text{Re}{\displaystyle\left(\frac{1}{\alpha_{\chi}}\right)}=-2\sigma_{1}^{2}\frac{\left(\rho\left(\mu^{2}+\xi^{2}\right)+2\left(\xi-1\right)^{2}\right)}{{\displaystyle\left(\mu^{2}+\rho\mu^{2}+1\right)}}\approx-2\sigma_{1}^{2}\rho=-2\sigma_{2}^{2} \displaystyle\text{Im}\left(\frac{1}{\alpha_{\chi}}\right)\approx 4\sigma_{1}^{2}\frac{\left(\xi-1\right)}{\mu}{\displaystyle\left(-\mu^{2}-\rho\mu^{2}+1\right)}\approx-\frac{\lambda L}{\pi}\left(1-\xi\right)\left(1-\mu^{2}\right) \displaystyle P_{2b}\approx\frac{4\pi\sigma_{1}\sigma_{2}}{\lambda L}\exp\left(-\frac{\mu^{2}}{2\sigma_{1}^{2}}(s_{1}-s_{2})^{2}\right)