Guaiazulene-Based 2‑Hydrazinylpyridine Probe (GAHP550) for Ultralow, Reversible Cu2+ Detection and Molecular Logic Gate Applications Authors: Mehmet Kaplan, Gabriele Kociok-Köhn, G. Dan Pantoş, Simon E. Lewis, Tony D. James Published: 2026 ABSTRACT A guaiazulene-derived 2-hydrazinylpyridine probe (GAHP550) was developed for the highly sensitive, selective, and reversible detection of Cu2+ ions, with seamless integration into a smartphone-based analytical platform. The probe was synthesized via a simple two-step procedure from commercially available guaiazulene in 88.7% overall yield, without the need for chromatographic purification. The structure was confirmed using NMR, HRMS, FTIR, and single-crystal X-ray diffraction. GAHP550 exhibits a rapid, visually perceptible green-to-brown color change upon Cu2+ binding, with a linear response between 5.0 × 10–7 and 1.2 × 10–3 M and an ultralow detection limit of 9.45 × 10–7 M (55.4 ppb), far below WHO (2.0 ppm) and EPA (1.3 ppm) recommended limits for drinking water. High selectivity was observed against a broad panel of competing cations and anions, and reversible sensing was demonstrated via multiple Cu2+/Na4EDTA cycles. The binding stoichiometry was determined as 1:2 (Cu2+: GAHP550) with a strong binding constant of 1.21 × 106 M–2. Interestingly, the probe functions as an INHIBIT-type molecular logic gate using Cu2+ and Na4EDTA as inputs. A smartphone application was developed to quantify Cu2+ concentrations in real-time using RGB analysis of the colorimetric transition. GAHP550 was then used to successfully quantify Cu2+ in tap and bottled water, achieving excellent recovery values of 83.5–104.2%, confirming the robustness and applicability in practical aqueous solutions. The integration of ultrahigh sensitivity, fast reversible response, logic gate functionality, and mobile-device compatibility establishes GAHP550 as a powerful, portable tool for environmental and field-based Cu2+ detection. Introduction Copper­(II) is the third most abundant essential metal ion in the human body after Fe3+ and Zn2+, − and functions as a crucial cofactor in numerous metalloenzymes, including tyrosinase, superoxide dismutase, , and cytochrome c oxidase. ,, It plays indispensable roles in hemopoiesis, iron homeostasis, mitochondrial respiration, and redox regulation. ,− Disruption of Cu2+ homeostasis can have severe pathological consequences. Both deficiency and excess of copper are implicated in neurodegenerative disorders (e.g., Alzheimer’s disease, − Parkinson’s disease, Wilson’s and Menkes , syndromes), cardiovascular and metabolic dysfunctions, hematological abnormalities, oxidative stress–related damage, skeletal malformations, and psychological conditions such as depression, anxiety, and cognitive impairment. Moreover, chronic overexposure to copper has been associated with carcinogenesis in liver, lung, oral, and prostate tissues. Beyond physiological relevance, Cu2+ is extensively utilized in industrial sectors including metallurgy, electronics, agriculture, construction, and energy materials. As such, improper waste management and industrial discharge can result in persistent Cu2+ accumulation in soil and aquatic ecosystems, posing substantial environmental and public health risks. − Consequently, regulatory agencies have established strict safety limits for copper in drinking water1.3 ppm (∼20 μM) by the United States Environmental Pollution Agency (EPA) and 2.0 ppm (∼30 μM) by the World Health Organization (WHO). , A wide range of analytical techniques have been employed for Cu2+ determination, such as atomic absorption spectroscopy, , inductively coupled plasma mass spectroscopy, inductively coupled plasma atomic emission spectrometry, , high-performance liquid chromatography, and electrochemical methods. , Although these approaches offer high sensitivity and selectivity, their practical deployment is limited by high instrumentation cost, need for trained operators, laborious sample preparation, and lack of portability. − As a result, colorimetric and spectrophotometric chemosensors have garnered increasing attention as low-cost, rapid, and field-deployable alternatives for Cu2+ monitoring. ,− Azulene, a non alternant bicyclic aromatic system comprising fused five- and seven-membered rings, exhibits exceptional physicochemical properties distinct from its naphthalene isomer. − Its intrinsic polarization, high dipole moment, and narrow HOMO–LUMO gap impart characteristic blue coloration and strong visible-region absorption, making it an attractive scaffold for functional material design. , Azulene derivatives have been successfully utilized in photonic materials, fluorescent and colorimetric sensors, molecular logic devices, and stimuli-responsive systems, with reported applications for CN–, Hg2+, Ag+, F–, NO2 –, PO4 3–, ATP, and reactive oxygen species detection. ,,,,− A pioneering early report from Wakabayashi et al. describes a colorimetric response to Cu2+ of some pyridylazulenes, but this was not quantified and selectivity over other transition metals (Pb2+, Hg2+, Cr3+) was minimal. Guaiazulene is a naturally occurring azulene-containing sesquiterpene which exhibits diverse bioactivitiesanti-inflammatory, antioxidant, antimicrobial, and epithelial healingand is an FDA-approved cosmetic ingredient. Guaiazulene derivatives have also been evaluated as food colorants. , Compared to azulene, guaiazulene offers advantages as a starting material, including commercial availability on scale and low cost. These features, combined with guaiazulene’s modifiable chromophoric framework, have stimulated increasing interest in guaiazulene-based sensing platforms. ,, Inspired by the principles of Boolean computation, molecular logic gates have emerged as chemical systems capable of executing logic functions (YES, NOT, AND, OR, INHIBIT, XOR, etc.) via analyte-induced signal variations. − Since the pioneering work of de Silva, the field has advanced toward integrated optical logic circuits and multi-input molecular computation for chemical information processing and smart sensing applications. ,,− Examples of use of azulene in molecular logic gates reported to date include in half adders and full adders, − as well as in AND and OR gates with chemical and optical inputs and electrical outputs. With this research, a guaiazulene-derived 2-hydrazinylpyridine-functionalized probe (GAHP550) was designed and synthesized for selective and sensitive Cu2+ detection. The probe offers high synthetic efficiency, requiring no chromatographic purification, and was fully characterized by NMR, HRMS, FTIR, and single-crystal X-ray diffraction. GAHP550 demonstrates rapid and reversible response toward Cu2+ with an ultralow detection limit of 9.45 × 10–7 M (55.4 ppb), well below EPA and WHO regulatory limits. Distinct green-to-brown color transition enables naked-eye sensing, and accurate quantification was achieved for bottled and tap water samples with excellent recovery values. Additionally, GAHP550 operates as an INHIBIT-type molecular logic gate and was successfully integrated into a smartphone-based analytical platform, highlighting its potential for portable environmental monitoring and real-world application. Materials and Methods Materials Zinc nitrate hexahydrate [Zn­(NO3)2•6H2O], 2-hydrazinylpyridine, potassium acetate, deuterated dimethyl sulfoxide (DMSO-d 6), deuterated chloroform (CDCl3) were purchased from Fluorochem Ltd. (Hadfield, England) and were used without any purification process. Lithium nitrate (LiNO3), sodium nitrate (NaNO3), potassium nitrate (KNO3), cesium nitrate (CsNO3), calcium nitrate hydrate [Ca­(NO3)2•xH2O], strontium nitrate [Sr­(NO3)2], barium nitrate [Ba­(NO3)2], chromium­(III) nitrate nonahydrate [Cr­(NO)3•9H2O], iron­(II) perchlorate hydrate [Fe­(ClO4)2•xH2O], cobalt­(II) nitrate hexahydrate [Co­(NO3)2•6H2O], nickel­(II) nitrate hexahydrate [Ni­(NO3)2•6H2O], copper­(II) nitrate hydrate [Cu­(NO3)2•xH2O], silver nitrate (AgNO3), mercury­(II) nitrate monohydrate [Hg­(NO3)2•H2O], aluminum nitrate nonahydrate [Al­(NO3)3•9H2O], potassium hydroxide (KOH), sodium sulfide (Na2S), sodium hydrosulfide hydrate [NaSH•xH2O], sodium sulfite (Na2SO3), sodium sulfate (Na2SO4), sodium bisulfite (NaHSO3), sodium hydrogen sulfate monohydrate (NaHSO4•H2O), sodium hydrosulfite (Na2S2O4), sodium nitrate (NaNO3), potassium thiocyanate (KSCN), sodium bicarbonate (NaHCO3), potassium carbonate (K2CO3), potassium dihydrogen phosphate (KH2PO4), disodium hydrogen phosphate (Na2HPO4), potassium permanganate (KMnO4), guaiazulene (99%), magnesium sulfate (MgSO4), sodium tetraborate decahydrate [Na2B4O7•10H2O], ethylenediaminetetraacetic acid tetrasodium salt dihydrate (Na4EDTA•2H2O) were purchased from Fisher Scientific (New Hampshire, USA) and were used without any purification process. Rubidium nitrate (RbNO3), ammonium nitrate (NH4NO3), magnesium nitrate hexahydrate [Mg­(NO3)2•6H2O], manganese­(II) nitrate hydrate [Mn­(NO3)2•xH2O], iron­(III) nitrate nonahydrate [Fe­(NO3)3•9H2O], cadmium nitrate tetrahydrate [Cd­(NO3)2•4H2O], tin­(II) chloride (SnCl2), tin­(IV) chloride (SnCl4), lead­(II) nitrate [Pb­(NO3)2], hydrazine monohydrate [NH2NH2•H2O], sodium fluoride (NaF), potassium chloride (KCl), potassium bromide (KBr), potassium iodide (KI), sodium hypochlorite solution (6–14% active chlorine) (NaClO), sodium thiosulfate (Na2S2O3), sodium metabisulfite (Na2S2O5), sodium nitrite (NaNO2), sodium acetate (CH3COONa), potassium phosphate tribasic (K3PO4), phosphorus­(V) oxychloride (POCl3), N,N-dimethylformamide (DMF), 2-amino-2-(hydroxymethyl)-1,3-propanediol (Trizma base), 2-[4-(2-hydroxyethyl)­piperazin-1-yl]­ethane-1-sulfonic acid (HEPES), sodium hydroxide (NaOH), pentane, ethyl acetate (EtOAc), glacial acetic acid (CH3CO2H), ethanol (EtOH), silica gel (high-purity grade, 200–400 mesh), thin layer chromatography (TLC) (silica gel 60 F-254 aluminum-backed) plates were purchased from Merck (Darmstadt, Germany) and all solvents and chemicals were used without any purification process. Dichloromethane (DCM) and hydrochloric acid (HCl) were purchased from VWR (Pennsylvania, USA). Apparatus UV–Vis spectroscopic measurements were performed at room temperature using an Agilent Cary 60 UV–Vis spectrophotometer and a BMG LabTech CLARIOstar microplate reader. A 1.0 cm path length quartz cuvette and 96-well flat-bottom microplates (Corning Costar) were employed for the measurements. During synthesis and solution preparation steps, an IKA RCT Basic magnetic stirrer hot plate, Sartorius analytical balance, Clifton ultrasonic bath, and Heidolph Hei-VAP Core rotary evaporator were utilized. 1H NMR and 13C NMR spectra were recorded on a Bruker Ascend 400 MHz spectrometer. High-resolution mass spectrometry (HRMS) analysis was conducted using an Agilent 6545 Q-TOF LC–MS system. Fourier-transform infrared (FTIR) spectra were acquired using a PerkinElmer Spectrum 100 FTIR spectrophotometer. The melting points were determined using a Stanford Research Systems OptiMelt Automated Melting Point Apparatus 100. Smartphone-based image acquisition and processing were carried out using a Samsung Galaxy S24 Ultra (SM-S928B/DS) device. X-ray Crystallography Single crystals of GAHP550, grown from chloroform, were used for X-ray diffraction analysis. The resulting solid-state structure is depicted in Figure . (a) Synthesis of 3-formylguaiazulene and (b) GAHP550. Solid-state structure of GAHP550. Thermal ellipsoids are drawn at 50% probability, and hydrogen atoms are depicted as spheres of arbitrary radius (CCDC: 2503754). Single-crystal X-ray diffraction data were collected on a Rigaku XtaLAB Synergy, Dualflex diffractometer equipped with a Cu microfocus source (λ = 1.54184 Å) and a HyPix-Arc 100 detector. Unit cell determination, data collection, data reduction, and multiscan (symmetry-related) absorption correction were performed using CrysAlisPro software. The crystal structure was solved using SHELXT and refined through full-matrix least-squares refinement on F 2 using SHELXL-2019/3. All non-hydrogen atoms were refined anisotropically. Hydrogen atoms were positioned geometrically and refined using a riding model. Synthesis of GAHP550 As shown in Figure , the probe was obtained in two steps. The 3-formylguaiazulene obtained in the first step was synthesized based on a literature procedure, and detailed information regarding its synthesis and characterization is provided in the Supporting Information (Figure a). In the second step, 226.3 mg (1.0 mmol) of 3-formylguaiazulene was dissolved in 10 mL of EtOH in a round-bottom flask, and 120.1 mg (1.1 mmol) of 2-hydrazinylpyridine along with 60.0 μL (1.0 mmol) of glacial acetic acid were added to the solution. The reaction mixture was refluxed at 80 °C for 1 h. After cooling to room temperature, the solvent was removed under reduced pressure. The obtained product was then recrystallized from EtOH, affording GAHP550 as a dark green solid (Figure b) (281.5 mg, 88.7% yield). R f: 0.30 (SiO2, 3:1 Pentane/EtOAc); mp = 160–162 °C; 1H NMR (DMSO-d 6, 400 MHz): δ = 10.60 (s, 1H, H-23), 8.93 (s, 1H, H-16), 8.15 (s, 1H, H-9), 8.07 (d, J = 4.1 Hz, 1H, H-21), 8.01 (d, J = 2.1 Hz, 1H, H-2) 7.60 (app t, J = 7.7 Hz, 1H, H-19), 7.33 (dd, J = 10.4, 2.1 Hz, 1H, H-4), 7.24 (d, J = 8.4 Hz, 1H, H-18), 6.95 (d, J = 10.5 Hz, 1H, H-5), 6.69 (dd, J = 7.1, 4.9 Hz, 1H, H-20), 3.03 (hept, J = 6.8 Hz, 1H, H-12), 2.89 (s, 3H, H-11), 2.57 (s, 3H, H-15), 1.29 (d, J = 6.8 Hz, 6H, H-13, H-14) ppm; 13C NMR (DMSO-d 6, 101 MHz): δ = 157.3 (C-17), 147.8 (C-21), 145.1 (C-6), 141.8 (C-3), 140.9 (C-1), 138.3 (C-16), 137.7 (C-19), 135.2 (C-9), 134.9 (C-4), 133.7 (C-2), 132.2 (C-7), 127.6 (C-5), 126.2 (C-10), 123.5 (C-8), 114.0 (C-20), 106.0 (C-18), 36.8 (C-12), 28.4 (C-11), 24.2 (C-13, C-14), 12.7 (C-15) ppm; IR (ATR): v max/cm–1 (neat) = 3181, 2944, 2856, 1597, 1536, 1441, 1312, 1282, 1137, 1087, 990, 898, 810, 761, 682, 649; HRMS (ESI+) m/z: [(C21H23N3) + H]+ theoretical: 318.1965; found, 318.1964. Preparation of Solutions for Spectral Measurements Stock solutions of all ions (Li+, Na+, K+, Rb+, Cs+, NH4 +, Mg2+, Ca2+, Sr2+, Ba2+, Cr3+, Mn2+, Fe2+, Fe3+, Co2+, Ni2+, Cu2+, Zn2+, Cd2+, Ag+, Hg2+, Al3+, Sn2+, Sn4+, Pb2+, N2H4, F–, Cl–, Br–, I–, OH–, ClO–, S2–, SH–, SO3 2–, SO4 2–, HSO3 –, HSO4 –, S2O3 2–, S2O4 2–, S2O5 2–, NO2 –, NO3 –, SCN–, CH3COO–, HCO3 –, CO3 2–, H2PO4 –, HPO4 2–, PO4 3–, MnO4 –) were prepared in distilled water at a concentration of 5.0 × 10–2 M. The solubility of GAHP550 in various water-miscible organic solvents was assessed. GAHP550 was observed to be only sparingly soluble in EtOH, MeOH, MeCN, DMF, and THF. In contrast, GAHP550 exhibited good solubility in DMSO, which was accordingly selected as the organic cosolvent for the measurements. A linear calibration graph of the GAHP550 probe was obtained in accordance with the Lambert–Beer law, and the optimal working concentration for GAHP550 was determined to be 1.0 × 10–3 M (Figure S2). 0.1 M HEPES buffer at pH 7.4 was selected as the aqueous component of the measurement solvent, as it provides the optimal response upon the addition of Cu2+, ensures suitable selectivity, and does not alter the intrinsic response of the probe (Figure S3). Additionally, experiments with various proportions of 0.1 M HEPES buffer at pH 7.4 revealed that solubility decreases with increasing buffer content, and the optimal buffer proportion was confirmed to be 15% (Figure S4). Thus, the optimal working conditions were determined to be 1.0 × 10–3 M GAHP550 with a binary solvent mixture consisting of 17:3 (v/v) DMSO/pH 7.4 HEPES (0.1 M). Titration studies were conducted by adding aqueous Cu­(NO3)2 to the medium at concentrations ranging from 5.0 × 10–7 to 1.2 × 10–3 M. In selectivity and interference studies, group 1A, 2A, and 3A cations were used at 20 equiv, anions at 10 equiv, and transition metals at 5 equiv. Reversibility, reusability, and logic gate applications were performed using 5.0 × 10–4 M Cu­(NO3)2 and 6.6 × 10–4 M Na4EDTA, respectively. For stability studies, the GAHP550 probe was stored in an amber flask at room temperature in a laboratory environment under a DMSO: H2O 17:3, v/v HEPES buffer at pH 7.4 mixture. Measurements were taken over a 100 day period, and the results were recorded. In response time studies, 5.0 × 10–4 M Cu­(NO3)2 was added to the medium containing the GAHP550 probe, and measurements were recorded over a period of 10 min. All experiments were conducted in triplicate. Smartphone Application In the smartphone application study, 1.0 × 10–3 M GAHP550 probe (DMSO/H2O 17:3, v/v, HEPES, pH 7.4, 0.1 M) was used, and aqueous Cu­(NO3)2 was added to the medium at concentrations ranging from 7.9 × 10–5 M to 4.2 × 10–4 M. Photographs were taken using a Samsung Galaxy S24 Ultra (SM-S928B/DS) mounted on a tripod within a mini photo studio to minimize potential vibrations and changes in lighting conditions. After each photograph was taken, three distinct points were selected, and the red/green/blue (RGB) values of these points were automatically calculated using a Python script. An increase in the green/red value was observed with increasing concentration, and a calibration graph was generated. Using the slope, intercept, and linear working range obtained from the calibration data, a mobile application named “GAHP550 Cu2+ Detector” was developed. Determination of Cu2+ in Real Samples In the real sample studies, tap water collected directly from the laboratory and two different bottled drinking water samples purchased from a supermarket in Bath, United Kingdom, were used. To perform the analyses, 5.0 × 10–2 M Cu­(NO3)2 solutions were prepared using the respective water samples, and all necessary dilutions were also made with the same water sources. All real sample analyses were performed in triplicate using a UV–vis spectrophotometer. Preparation of Cotton Buds For the colorimetric selectivity and titration studies using cotton buds, a 1.0 × 10–3 M stock solution of GAHP550 was first prepared in DMSO/pH 7.4 HEPES (0.1 M) (17:3, v/v). The cotton buds were then immersed in this solution for 1 min to allow complete impregnation with the probe. After impregnation, the cotton buds were removed and allowed to dry at room temperature. For the titration study, 5.0 mL aqueous stock solutions of Cu­(NO3)2.3H2O were prepared at 0.10, 0.25, 0.50, 0.75, 1.00, 1.50, 2.00, 3.00, 4.00, 5.00, 6.00, 7.00, 8.00, 9.00, and 10.00 equiv. The probe-impregnated cotton buds were immersed in each Cu2+ solution for 30 s, removed, and immediately photographed. For the colorimetric selectivity study, all competing ions were prepared as 5.0 mL solutions at 5.0 equiv. The probe-coated cotton buds were immersed individually in each competing ion solution for 30 s before being removed and photographed. All photographs were acquired using a Samsung Galaxy S24 Ultra (SM-S928B/DS) mounted on a tripod inside a mini photo studio to minimize the effects of vibration and fluctuations in ambient lighting. Results and Discussion Design, Synthesis and Structural Characterization of GAHP550 A guaiazulene-derived 2-hydrazinylpyridine-modified probe, designated GAHP550, was designed for the selective, sensitive, and colorimetric detection of Cu2+ ions. As illustrated in Figure , GAHP550 was synthesized in two steps. First, 3-formylguaiazulene was obtained from commercially available guaiazulene following a reported procedure and structural confirmation was achieved through 1H NMR, 13C NMR, and HRMS analysis (Figures S5–S7). In the second step, condensation of 3-formylguaiazulene with 2-hydrazinopyridine in ethanol in the presence of glacial acetic acid afforded the target probe GAHP550 in a high yield of 88.7%, in 1 h. Notably, the product was obtained in pure form without the need for chromatographic purification, requiring only recrystallization. Structural confirmation was achieved using 1H NMR, 13C NMR, COSY, NOESY, HSQC, HMBC, FT-IR, HRMS (Figures S8–S15), and single-crystal X-ray diffraction (Figure S28 and Tables S1–S8) analyses. Diagnostic changes in the 1H NMR spectra were observed, with the aldehyde signal in the starting material (δ = 10.64 ppm) being replaced by the hydrazone signal in GAHP550 (δ = 8.93 ppm), as well as the appearance of the N–H signal (δ = 10.60 ppm). Analogously, in the 13C NMR spectra, the aldehyde signal (δ = 186.4 ppm) shifts significantly upfield upon hydrazone formation (δ = 138.3 ppm). Spectral Response to Cu2+ and other Competitive Ions The spectral response of the GAHP550 probe in the presence of various ions was examined under the conditions of DMSO/H2O (17:3, v/v, HEPES, pH 7.4). As shown in Figure , the probe exhibits a maximum absorbance peak around 640 nm, which shifts to approximately 550 nm upon the addition of Cu2+. This spectral change was accompanied by a visible color transition of the probe from green to brown with increasing concentrations of Cu2+. In contrast, no significant spectral changes were observed in the presence of competing cations and anions. The bar graph presented in Figure clearly demonstrates that the GAHP550 probe exhibits high selectivity toward Cu2+ ions. Additionally, to evaluate the stability of the probe, its spectrophotometric response was monitored over a 100 day period. As shown in Figure S18, the response of GAHP550 remained constant throughout this period, indicating its suitability for long-term use and reliable Cu2+ detection. Bar graph presents the response of GAHP550 (1.0 × 10–3 M) in the presence of Cu2+ and various potentially competing ions (1: Li+, 2: Na+, 3: K+, 4: Rb+, 5: Cs+, 6: NH4 +, 7: Mg2+, 8: Ca2+, 9: Sr2+, 10: Ba2+, 11: Cr3+, 12: Mn2+, 13: Fe2+, 14: Fe3+, 15: Co2+, 16: Ni2+, 17: Cu2+, 18: Zn2+, 19: Cd2+, 20: Ag+, 21: Hg2+, 22: Al3+, 23: Sn2+, 24: Sn4+, 25: Pb2+, 26: N2H4, 27: F–, 28: Cl–, 29: Br–, 30: I–, 31: OH–, 32: ClO–, 33: S2–, 34: SH–, 35: SO3 2–, 36: SO4 2–, 37: HSO3 –, 38: HSO4 –, 39: S2O3 2–, 40: S2O4 2–, 41: S2O5 2–, 42: NO2 –, 43: NO3 –, 44: SCN–, 45: CH3COO–, 46: HCO3 –, 47: CO3 2–, 48: H2PO4 –, 49: HPO4 2–, 50: PO4 3–, 51: MnO4 –). The inset displays the corresponding UV–vis absorption profiles recorded after sequential introduction of Cu2+ and competing ions. Measurements were performed in a DMSO/H2O (17:3, v/v) medium buffered with 0.1 M HEPES at pH 7.4. Ions numbered 1–10, 27–31, 42, 43, and 45–51 were used at 20 equiv; ions numbered 11–16, 18–26, 32–41, and 44 were used at 5 equiv, while ion 17 (Cu2+) was used at 1 equiv. Error bars represent the standard deviation of three independent measurements (n = 3). The colorimetric selectivity of GAHP550 toward Cu2+ can be clearly observed in Figure . Initially green in color, the GAHP550 probe retains its green hue in the presence of all other competing analytes, whereas in the presence of Cu2+, it immediately changes to brown. Distinct visual color variations were recorded when GAHP550 (1.0 × 10–3 M) was treated with Cu2+ and a series of competing ions in a DMSO/H2O (17:3, v/v) system buffered with 0.1 M HEPES at pH 7.4. Li+, Na+, K+, Rb+, Cs+, NH4 +, Mg2+, Ca2+, Sr2+, Ba2+, F–, Cl–, Br–, I–, OH–, NO2 –, NO3 –, CH3COO–, HCO3 –, CO3 2–, H2PO4 –, HPO4 2–, PO4 3–, and MnO4 – were used at 20 equiv, whereas Cr3+, Mn2+, Fe2+, Fe3+, Co2+, Ni2+, Zn2+, Cd2+, Ag+, Hg2+, Al3+, Sn2+, Sn4+, Pb2+, N2H4, ClO–, S2–, SH–, SO3 2–, SO4 2–, HSO3 –, HSO4 –, S2O3 2–, S2O4 2–, S2O5 2– and SCN– were used at 5 equiv. Cu2+ was used at 1 equiv. Additionally, the titration study revealed that increasing equivalents of Cu2+ in the medium led to a corresponding increase in absorbance at 550 nm (Figure ). Based on the obtained linear calibration graph, the limit of detection (LOD) was calculated using the formula LOD = 3 × SD/S, resulting in a value of 9.45 × 10–7 M (55.4 ppb). Here, SD represents the standard deviation of blank measurements (0.00049), and S is the slope of the linear calibration graph. Titration profile of GAHP550 (1.0 × 10–3 M) upon incremental addition of Cu2+, demonstrating a progressive absorbance enhancement with increasing ion concentration. Inset: UV–vis spectra recorded during the titration, along with a linear calibration curve obtained over the concentration range of 5.0 × 10–7–3.7 × 10–4 M. Experimental medium: DMSO/H2O (17:3, v/v) containing 0.1 M HEPES buffer at pH 7.4. Error bars represent the standard deviation of three independent measurements (n = 3). To investigate the binding mode between GAHP550 and Cu2+ ions, a Job’s plot analysis was performed. In this study, the total concentration was kept constant at 1.0 × 10–4 M, with varying molar ratios of Cu2+. As shown in the resulting graph (Figure S19), the binding mode was determined to be 1:2 (Cu2+/GAHP550). Based on the identified binding stoichiometry and the UV–vis data obtained from the titration experiment, the binding constant was calculated to be 1.21 × 106 M–2 (Figure S20). Examination of Interference Effects An interference study was conducted to determine whether the spectrophotometric and colorimetric changes observed for GAHP550 in the presence of Cu2+ ions could also occur in the presence of other potential competing ions. In this study, the addition of various competing ions (Li+, Na+, K+, Rb+, Cs+, NH4 +, Mg2+, Ca2+, Sr2+, Ba2+, F–, Cl–, Br–, I–, OH–, NO2 –, NO3 –, CH3COO–, HCO3 –, CO3 2–, H2PO4 –, HPO4 2–, PO4 3–, and MnO4 – (20 equiv); Cr3+, Mn2+, Fe2+, Fe3+, Co2+, Ni2+, Zn2+, Cd2+, Ag+, Hg2+, Al3+, Sn2+, Sn4+, Pb2+, N2H4, ClO–, S2–, SH–, SO3 2–, SO4 2–, HSO3 –, HSO4 –, S2O3 2–, S2O4 2–, S2O5 2–, and SCN– (5 equiv)) to the Cu2+-containing medium showed no significant interference effects, confirming that Cu2+ can be accurately detected by GAHP550 even in the presence of these ions (Figure ). Only a partial interference was observed in the presence of Hg2+; however, this effect was successfully masked by the addition of Na2S2O3 to the medium. Interference experiments were conducted by introducing Cu2+ into GAHP550 (1.0 × 10–3 M) solutions containing various potentially competing ions (1: Li+ + Cu2+, 2: Na+ + Cu2+, 3: K+ + Cu2+, 4: Rb+ + Cu2+, 5: Cs+ + Cu2+, 6: NH4 + + Cu2+, 7: Mg2+ + Cu2+, 8: Ca2+ + Cu2+, 9: Sr2+ + Cu2+, 10: Ba2+ + Cu2+, 11: Cr3+ + Cu2+, 12: Mn2+ + Cu2+, 13: Fe2+ + Cu2+, 14: Fe3+ + Cu2+, 15: Co2+ + Cu2+, 16: Ni2+ + Cu2+, 17: Cu2+, 18: Zn2+ + Cu2+, 19: Cd2+ + Cu2+, 20: Ag+ + Cu2+, 21: Hg2+ + Cu2+, 22: Al3+ + Cu2+, 23: Sn2+ + Cu2+, 24: Sn4+ + Cu2+, 25: Pb2+ + Cu2+, 26: N2H4 + Cu2+, 27: F– + Cu2+, 28: Cl– + Cu2+, 29: Br– + Cu2+, 30: I– + Cu2+, 31: OH– + Cu2+, 32: ClO– + Cu2+, 33: S2– + Cu2+, 34: SH– + Cu2+, 35: SO3 2– + Cu2+, 36: SO4 2– + Cu2+, 37: HSO3 – + Cu2+, 38: HSO4 – + Cu2+, 39: S2O3 2– + Cu2+, 40: S2O4 2– + Cu2+, 41: S2O5 2– + Cu2+, 42: NO2 – + Cu2+, 43: NO3 – + Cu2+, 44: SCN– + Cu2+, 45: CH3COO– + Cu2+, 46: HCO3 – + Cu2+, 47: CO3 2– + Cu2+, 48: H2PO4 – + Cu2+, 49: HPO4 2– + Cu2+, 50: PO4 3– + Cu2+, 51: MnO4 – + Cu2+). The measurements were performed in a DMSO/H2O (17:3, v/v) mixture buffered with 0.1 M HEPES at pH 7.4. Ions numbered 1–10, 27–31, 42, 43, and 45–51 were used at 20 equiv; ions numbered 11–16, 18–26, 32–41, and 44 were used at 5 equiv, while ion 17 (Cu2+) was used at 1 equiv. To suppress interference from Hg2+, Na2S2O3 was employed at a 4-fold molar excess relative to Hg2+ ions (entry 21). Error bars represent the standard deviation of three independent measurements (n = 3). In addition to evaluating the interference effects of individual competing analytes on the response of GAHP550 toward Cu2+, a mixed-ion system containing all potential interfering species was also evaluated. To eliminate the possible interference caused by Hg2+, Na2S2O3 was added to the medium. The results demonstrated that even in the presence of mixed ions at different equivalents, Cu2+ could still be successfully detected using the GAHP550 probe (Figure S21). Determination of Response Time To determine the response time for Cu2+ detection using the GAHP550 probe, UV–vis measurements were recorded using a microplate reader at 10 s intervals over a 10 min period. Upon the addition of Cu2+ to the probe solution, an increase in absorbance at 550 nm was observed, accompanied by a rapid (<10 s) color change from green to brown, which remained nearly constant throughout the 10 min period (Figure S22). Based on these results, it can be concluded that Cu2+ detection with the GAHP550 probe occurs near-instantaneously and represents a more rapid response compared to the previous systems outlined in Table . 1Comparison of Analytical Performance Parameters of GAHP550 with Previously Reported Cu2+-Detecting Probesprobe nosolvent mediumcolorimetric changeresponse timelimit of detection (LOD)smartphone measurementsreversible and reusablelogic gate applicationrefswithout dedicated appwith dedicated app1THF/H2O (1:1, v/v, pH 7.4 tris buffer)yes45 s2.07 × 10–7 Myesnoyesno 20.02 M citrate-sodium citrate bufferyes6 min3.60 × 10–7 Myesnonono 3DMSO/H2O (1:9, v/v, pH 7.4 HEPES)yes1 min1.48 × 10–7 Myesnoyesno 4acetone/H2O (2:3, v/v, pH 7.4 HEPES 0.01 M)yes200 s3.08 × 10–7 Mnonoyesno 5EtOH/H2O (4:1, v/v, pH 6.3, 20 mM HEPES)no5 min3.30 × 10–7 Mnonoyesno 6DMSO: CH3CN (7:3, v/v)yes-4.80 × 10–7 Mnonoyesno 7MeOH/H2O (9:1, v/v, pH 7.0 PBS 10 mM)yes-5.50 × 10–7 Mnonoyesno 8Tris–HCl/ethanol (1:1, v/v, pH 7.4)yes∼50 min6.23 × 10–7 Mnononono 9MeOH: H2O (1:1, v/v, pH 7.2 Tris)yes-2.04 × 10–7 Mnonoyesyes 10DMSO/H2O (17:3, v/v, pH 7.4 HEPES 0.1 M)yes<10 s9.45 × 10–7 Myesyesyesyesthis work Comparison of Analytical Performance Parameters of GAHP550 with Previously Reported Cu2+-Detecting Probes Reversibility and Reusability To evaluate the reversibility of GAHP550 colorimetric and spectrophotometric response toward Cu2+, Na4EDTA (0.67 equiv) was added following the introduction of Cu2+ ions (0.5 equiv). The formation of the Cu2+–EDTA complex resulted in a substantial, although partial, recovery of both the absorbance and colorimetric responses. Based on absorbance measurements, the recovery efficiency per cycle ranged from 75.7% to 95.5%, with an average of approximately 83.5%. Subsequent readdition of Cu2+ reproduced comparable responses. As shown in Figure S23, this reversible cycle was successfully repeated seven times, demonstrating the good reversibility and reusability of the probe. Proposed Binding Mode between GAHP550 and Cu2+ The previously obtained Job’s plot analysis (Figure S19) indicated a 1:2 metal/ligand binding stoichiometry, consistent with the formation of a Cu­(GAHP550) 2 complex. This assignment was further supported by HRMS analysis (Figure S24). In addition, the 1H, COSY, and NOESY NMR spectra (Figures S16 and S17) of Cu­(GAHP550) 2 confirm the 1:2 metal/ligand stoichiometry and indicate that the complex is not symmetric, with the two GAHP550 ligands being inequivalent. In order to further explore the structure of this complex we undertook DFT studies (BHLYP/D3BJ/def2-TZVP/SMD­(H2O)) − using a penta-coordinated Cu­(II) center with 2 × 2 co-ordination sites being occupied by the N-donor ligands of the GAHP550 (pyridine N and –NC–) while the fifth co-ordination site is occupied by an aqua ligand. Of the four different optimized geometries (Figure S29) the structure with the lowest energy (Table S9) is consistent with the 1H NMR data and the UV–vis spectrum predicted via TDDFT (BHLYP/D3BJ/def2-TZVP/SMD­(H2O)) has a high similarity factor when compared with the experimental spectrum (Figure ). Comparison of the experimental and computed UV–vis spectrum of Cu­(GAHP550) 2 with the computed electronic transitions indicated with black vertical lines (similarity factor of 0.977); DFT predicted structure of Cu­(GAHP550) 2 . Logic Gate Applications In recent years, molecular logic gate applications have also gained increasing attention in chemical sensing studies. ,− ,, The reversible spectrophotometric and colorimetric response of GAHP550 toward Cu2+ in the presence of Na4EDTA enabled its use in a molecular logic gate system. In this system, Cu2+ and Na4EDTA were considered as Input 1 and Input 2, respectively, while the output was defined either as the color change or the absorbance variation at 550 nm (A550) (Figure ). (a) Logic diagram representing the INHIBIT gate behavior based on the absorbance response at 550 nm; (b) corresponding logic circuit illustrating the INHIBIT operation derived from the observed color transition. When A550 was monitored with a threshold value of 0.4, the absence of both Cu2+ and Na4EDTA resulted in an absorbance below 0.4, corresponding to an output of 0. The presence of Cu2+ alone increased the absorbance above 0.4, giving an output of 1. However, when both Cu2+ and Na4EDTA were present, or when only Na4EDTA was present, the absorbance remained below 0.4, giving an output of 0 (Figure S25). Therefore, the system produced an output of 1 only in the Input 1 AND NOT Input 2 condition, while in all other cases the output was 0 (Table ). This clearly demonstrates that the designed system functions as an INHIBIT logic gate, which represents the combination of AND and NOT operations (Figure ). Similarly, when the output is defined as the color change, green as 0 and brown as 1, the same logic behavior is observed, further confirming that the GAHP550 based system successfully mimics an INHIBIT logic gate (Figure S26). 2Truth Table Illustrating the Operational Logic of the INHIBIT Gateinput 1: Cu2+ input 2: Na4EDTAoutput: A550 output: color change0000101101001100 Truth Table Illustrating the Operational Logic of the INHIBIT Gate Real Sample Studies To evaluate the applicability of GAHP550 for Cu2+ detection in real samples, experiments were conducted using two different bottled drinking water samples and a tap water sample. In this study, the real samples were spiked with Cu­(NO3)2, and the results were compared with those obtained from Cu2+ samples prepared in pure water to calculate the recovery values. As shown in the Table , Cu2+ additions at concentrations of 0.50, 55.00, and 273.00 μM resulted in excellent recovery values ranging from 83.5% to 104.2%. These findings clearly demonstrate that Cu2+ detection using the GAHP550 probe can be successfully achieved in real water samples. 3Cu2+ Recovery Performance and Associated RSD Values Obtained from Real-Sample Studies Using Multiple Bottled Water Sources and Tap Water Matricessampleadded Cu2+ (μM)found Cu2+ (μM)recovery (%)RSD (n = 3)tap water0.500.4895.010.2 55.0050.0891.10.99 273.00227.8283.50.69drinking water-10.500.5100.55.47 55.0053.1796.71.49 273.00232.9285.31.22drinking water-20.500.52104.22.63 55.0053.6197.51.34 273.00234.8686.00.42 Cu2+ Recovery Performance and Associated RSD Values Obtained from Real-Sample Studies Using Multiple Bottled Water Sources and Tap Water Matrices Smartphone Based Cu2+ Detection A smartphone application was developed based on the color transition of GAHP550 from green to brown with increasing Cu2+ concentrations. For this purpose, a titration experiment was conducted to capture the color response of GAHP550 toward Cu2+, and photographs were taken throughout the process. Three common pixel points were identified across all images, and their red, green, and blue (RGB) values were calculated using a custom Python code that evaluated all possible variations. The analysis revealed that the red/green (R/G) ratio increased linearly with the rising Cu2+ concentration. A linear calibration curve was then constructed, with Cu2+ concentration plotted on the X-axis and the R/G ratio on the Y-axis (Figure ). A calibration plot was generated by correlating increasing Cu2+ concentrations (7.9 × 10–5–4.2 × 10–4 M) with the R/G intensity ratio obtained through the smartphone application. Inset: visual representation of the progressive color transition of GAHP550 (1.0 × 10–3 M) upon exposure to rising Cu2+ levels (0–4.5 × 10–4 M) under the same conditions. Measurement medium: DMSO/H2O (17:3, v/v) with 0.1 M HEPES buffer at pH 7.4. Error bars represent the standard deviation of three independent measurements (n = 3). Using the slope, intercept, and linear range obtained from this calibration curve, an Android mobile application named “GAHP550 Cu2+ Detector” was developed. When a photograph is taken directly via the smartphone, the application automatically selects a defined region, calculates the average R/G value, and determines the Cu2+ concentration in both M and ppm units if the value falls within the established linear range. If the value lies outside this range, the application notifies the user accordingly (Figure S27). The application developed in this study provides a more user-friendly operation compared with existing smartphone-based applications reported in the literature. As summarized in Table , many of the smartphone applications reported to date require multiple user inputs to obtain the final result. In contrast, with the “GAHP550 Cu2+ Detector” application, color selection from the captured image, matching of the obtained response with the calibration curve, and determination of the corresponding Cu2+concentration are performed fully automatically. This automated workflow minimizes user intervention and offers clear advantages in terms of user experience, practicality, and ease of operation. The ability to perform accurate Cu2+ detection using only a smartphone and the GAHP550 probe highlights the strong potential of this system for practical and field-based analytical applications. Deployment on Cotton Buds To evaluate the practical applicability of the probe, a cotton bud-based colorimetric assay was also developed. Probe-coated cotton buds were prepared by immersing them in a 1.0 × 10–3 M GAHP550 solution in DMSO/pH 7.4 HEPES (0.1 M) (17:3, v/v) and allowing them to dry at room temperature. The dried cotton buds were then immersed in Cu2+ solutions containing different equivalents of the metal ion and subsequently photographed. As shown in Figure , the initially green probe-coated cotton buds exhibited a distinct color transition from yellow to brown with increasing Cu2+ concentration. To further assess the selectivity of this platform, the probe-coated cotton buds were exposed to various competing ions under identical conditions. As illustrated in Figure , no noticeable color change was observed for any of the competing species, whereas a clear color transition occurred exclusively in the presence of Cu2+. Colorimetric response of GAHP550-coated cotton buds after immersion for 30 s in Cu2+ solutions containing 0–10 equiv of Cu2+. The cotton buds were preimpregnated with 1.0 × 10–3 M GAHP550 in DMSO/pH 7.4 HEPES (0.1 M) (17:3, v/v) and dried at room temperature prior to use. Colorimetric selectivity of GAHP550-coated cotton buds toward Cu2+ in the presence of competing ions (5.0 equiv). The cotton buds were preimpregnated with 1.0 × 10–3 M GAHP550 in DMSO/pH 7.4 HEPES (0.1 M) (17:3, v/v), dried at room temperature, and immersed in each ion solution for 30 s prior to photography. These results demonstrate that GAHP550-impregnated cotton buds provide a simple, highly selective, and sensitive platform for the visual detection of Cu2+, highlighting their potential for practical on-site applications. Conclusion Our guaiazulene-based probe GAHP550 provides a rapid, reversible, and highly selective platform for Cu2+ detection, achieving an ultralow detection limit of 9.45 × 10–7 M (55.4 ppb), well below WHO and EPA thresholds. Its 1:2 binding stoichiometry and high binding constant (1.21 × 106 M–2) ensure strong affinity and reproducible sensing. The probe exhibits INHIBIT-type molecular logic gate functionality, enabling chemical information processing through analyte-triggered optical outputs. In real sample analysis, GAHP550 accurately quantified Cu2+ in tap and bottled water with excellent recovery values ranging from 83.5–104.2%, demonstrating robustness in practical matrices. A dedicated smartphone application was developed to quantify Cu2+ concentrations in real-time using RGB analysis of the colorimetric transition, enabling precise on-site monitoring and mobile-based detection. By combining ultrahigh sensitivity, instantaneous colorimetric response, reversibility, logic-gate operation, and mobile-readout capability, GAHP550 represents a versatile tool for both laboratory and field-based Cu2+ monitoring, highlighting the potential of portable chemical sensors in smart practical analytical applications. Supplementary Material