Application of musculoskeletal ultrasound in postoperative rehabilitation assessment and monitoring after rotator cuff repair: A systematic review Authors: Ying Shi, Yi Bao, Chuanxiong Li, Wencai Liu, Wencai Liu, Wencai Liu Published: 2026 ABSTRACT BackgroundThe development of rehabilitation protocols after rotator cuff repair has long lacked objective benchmarks. Traditional time‑based regimens are limited by considerable inter‑individual variability and an increased risk of re‑tear. Musculoskeletal ultrasound allows dynamic assessment of tendon healing and muscle morphology, yet evidence for directly linking its use to rehabilitation decisions remains scarce.ObjectiveTo systematically synthesize the evidence on the use of musculoskeletal ultrasound monitoring to inform rehabilitation decision‑making after rotator cuff repair.MethodsFollowing the Preferred Reporting Items for Systematic Reviews and Meta‑Analyses (PRISMA) guidelines, we searched PubMed, China National Knowledge Infrastructure (CNKI), and Wanfang Data from January 2020 to April 2026. Original studies were included if they involved patients who had undergone rotator cuff repair, used musculoskeletal ultrasound (including gray‑scale ultrasound, elastography, etc.) to evaluate the rotator cuff tendons or shoulder muscles, and reported at least one parameter related to rehabilitation decision-making or functional outcomes.ResultsEleven studies were included. Shear wave velocity (SWV), cross‑sectional area (CSA), and echo intensity (EI) were the most frequently reported ultrasound parameters. Available evidence indicated that SWV increased progressively after surgery, with an overall increase of approximately 22% to 25% from one week to 12 months postoperatively. This dynamic trajectory may serve as a reference baseline for judging rehabilitation progress. An abnormally elevated SWV in the early postoperative period was associated with an increased risk of re‑tear, suggesting that a more conservative rehabilitation strategy should be adopted. Tendon stiffness measured at 12 weeks after surgery independently predicted long‑term return to sport. Regarding muscle parameters, changes in CSA and EI were positively correlated with shoulder function scores, and the combination of these two parameters effectively identified patients with rehabilitation bottlenecks.ConclusionMusculoskeletal ultrasound parameters are associated with the initiation of active movement, adjustment of exercise load, prediction of return‑to‑sport prognosis, and identification of retear risk. Among these, SWV shows particular promise as an objective monitoring parameter for supporting rehabilitation assessment after rotator cuff repair. Future randomized controlled trials are needed to determine whether ultrasound-informed assessment can improve rehabilitation outcomes compared with traditional time-based regimens, and to establish standardized measurement protocols and clinically applicable reference values. Key findings of this review are summarized in S1 File. 1 Introduction Rotator cuff tear is one of the most common musculoskeletal disorders [1]. Arthroscopic rotator cuff repair is currently the mainstream surgical treatment for symptomatic full-thickness tears, as it effectively improves shoulder function and reduces pain [2]. Nevertheless, postoperative healing of the repaired tendon and functional recovery are influenced by multiple factors [3], and the design of the rehabilitation protocol is a key determinant of postoperative outcomes [4]. 1.1 Rehabilitation challenges after rotator cuff repair: Limitations of traditional time‑driven protocols Rehabilitation after rotator cuff repair must balance two conflicting needs: sufficient immobilization to protect the repair interface and promote tendon-to-bone healing, and early mobilization to prevent joint stiffness, muscle atrophy, and adhesion formation. Postoperative shoulder stiffness is a common complication, closely associated with insufficient rehabilitation training and excessive immobilization [5]. Meanwhile, the reported retear rate after rotator cuff repair ranges from 15% to 21%, and can reach as high as 94% in cases of massive tears [6]. A number of systematic reviews and meta-analyses have shown that although retears have a negative effect on functional recovery, the effect size is modest and does not reach the threshold for clinical significance. This means that some patients may still achieve acceptable functional outcomes despite a retear — a finding that suggests postoperative rehabilitation decisions should not be informed solely by the goal of “absolute prevention of retears.” This observation is supported by the evidence from Holtedahl et al. [7]. In addition, age, tear size, fatty infiltration, muscle atrophy, and the appropriateness of the postoperative rehabilitation protocol have all been identified as significant risk factors for retear [8]. Traditional “one-size-fits-all” protocols that rely on fixed time points neglect the substantial inter-individual variability in tear characteristics, tissue quality, and healing trajectory. There is a clear need to shift toward a precision rehabilitation model based on the patient’s individual tissue healing status. 1.2 Technical advantages of musculoskeletal ultrasound: non‑invasive, bedside, dynamic, and quantifiable assessment of tendon healing and muscle morphology Musculoskeletal ultrasound is a non-invasive, real-time, and reproducible imaging modality that has recently demonstrated distinct advantages in the postoperative assessment of rotator cuff repair [9,10]. Advances in high-frequency transducers have enabled clearer visualization of fine tendon structures, panoramic imaging allows larger-scale structural assessment, and the introduction of elastography makes it possible to quantitatively evaluate the biomechanical properties of tendons and muscles [11]. Compared with magnetic resonance imaging, musculoskeletal ultrasound offers several practical benefits, including bedside applicability, dynamic imaging capability, and repeatable follow-up [12]. It also avoids artifacts caused by metal implants, making it particularly suitable for postoperative rehabilitation monitoring [13]. Musculoskeletal ultrasound can be used not only for the differential diagnosis of rotator cuff tears but also for assessing surgical outcomes and supporting rehabilitation monitoring at different postoperative stages [11]. In recent years, ultrasound elastography has also seen important progress in the preoperative evaluation of rotator cuff tears. Zhang et al. (2024) analyzed 106 patients who underwent arthroscopic rotator cuff repair and found that preoperative shear wave velocity (SWV) and elastic modulus were positively correlated with the Constant score at one year postoperatively. The combination of these two parameters predicted postoperative retear with an area under the curve (AUC) of 0.95 and a sensitivity of 91.70%, indicating that preoperative ultrasound parameters can effectively predict long-term functional outcomes and retear risk [14]. 1.3 Research gap: existing reviews focus on diagnosis or treatment; none have systematically synthesized the evidence linking ultrasound monitoring with rehabilitation-related decisions In recent years, the application of musculoskeletal ultrasound in rehabilitation after rotator cuff repair has gradually shifted from “structural assessment” to “functional monitoring.” Existing reviews have systematically summarized the normal sonographic appearances of the postoperative rotator cuff and common complications [15], and others have compared the use of ultrasound versus MRI in the postoperative setting [13]. In addition, clinical studies have confirmed that postoperative strain elastography scores are significantly correlated with muscle strength and function [16], that musculoskeletal ultrasound combined with shear wave elastography can assess tendon healing status after surgery for different tear types [17], and that changes in ultrasound parameters are positively correlated with shoulder function recovery [18]. However, most of these studies remain at the level of monitoring; they have not systematically summarized how ultrasound parameters can be directly translated into rehabilitation decisions (e.g., when to initiate active movement, how to adjust load intensity, or how to predict prognosis). In other words, although a large number of studies have used musculoskeletal ultrasound to monitor postoperative rehabilitation, a systematic review specifically focusing on how musculoskeletal ultrasound monitoring may inform rehabilitation decision-making after rotator cuff repair is still lacking. 1.4 Study objective Accordingly, the aim of this systematic review is to systematically search and synthesize the available literature to answer the following core question: which ultrasound parameters, at what postoperative time points, and in what manner have been used to inform adjustments of rehabilitation protocols after rotator cuff repair? By systematically mapping the evidence linking ultrasound parameters to rehabilitation decisions, this review seeks to provide clinicians with evidence‑based support for ultrasound‑informed precision rehabilitation, to identify key gaps in the current evidence base, and to offer directions for future research. 2 Methods This systematic review was designed and reported in accordance with the Preferred Reporting Items for Systematic Reviews and Meta‑Analyses (PRISMA) 2020 statement [19]. The study protocol was registered with PROSPERO (International Prospective Register of Systematic Reviews). The completed PRISMA 2020 checklist is provided in S1 Checklist. 2.1 Registered The protocol for this systematic review was registered with the PROSPERO International Prospective Register of Systematic Reviews (registration number: CRD420261418165). 2.2 Search strategy Searches were conducted in three electronic databases: PubMed, China National Knowledge Infrastructure (CNKI), and Wanfang Data Knowledge Service Platform. The search period covered January 2020 to April 2026, and the language was restricted to English and Chinese. For PubMed, the following search string was used: (“rotator cuff repair” AND (ultrasound OR elastography) AND (rehabilitation OR decision)). For the Chinese databases, the search strings were adapted accordingly: CNKI: SU=(’肩袖’ + ‘冈上肌’) * (’修复’ + ‘修补’ + ‘关节镜’) * (’超声’ + ‘肌骨超声’ + ‘弹性成像’) * (’康复’ + ‘术后’ + ‘功能恢复’ + ‘训练’); Wanfang Data: (主题:(肩袖) OR 主题:(冈上肌)) AND (主题:(修复) OR 主题:(修补) OR 主题:(关节镜)) AND (主题:(超声) OR 主题:(肌骨超声) OR 主题:(弹性成像)) AND (主题:(康复) OR 主题:(功能恢复) OR 主题:(术后) OR 主题:(训练)). The complete electronic search strategies are provided in S2 File. 2.3 Inclusion and exclusion criteria The inclusion and exclusion criteria were defined according to the PICOS framework as follows. 2.3.1 Inclusion criteria. (1) Population: Patients who underwent arthroscopic or open rotator cuff repair, regardless of tear type (full‑thickness or partial‑thickness) or tear size. (1) Population: Patients who underwent arthroscopic or open rotator cuff repair, regardless of tear type (full‑thickness or partial‑thickness) or tear size. (2) Intervention/Exposure: Assessment using musculoskeletal ultrasound, including but not limited to gray‑scale ultrasound, Doppler ultrasound, shear wave elastography (SWE), and real‑time tissue elastography (RTE). (2) Intervention/Exposure: Assessment using musculoskeletal ultrasound, including but not limited to gray‑scale ultrasound, Doppler ultrasound, shear wave elastography (SWE), and real‑time tissue elastography (RTE). (3) Outcomes: A clear association between ultrasound parameters and either rehabilitation decision‑making (e.g., timing of initiation or progression of active movement, load intensity adjustment, return‑to‑sport determination, retear risk warning) or functional outcomes (e.g., Constant score, ASES score, range of motion, muscle strength). (3) Outcomes: A clear association between ultrasound parameters and either rehabilitation decision‑making (e.g., timing of initiation or progression of active movement, load intensity adjustment, return‑to‑sport determination, retear risk warning) or functional outcomes (e.g., Constant score, ASES score, range of motion, muscle strength). (4) Study type: Randomized controlled trials, prospective or retrospective cohort studies, case‑control studies, or case series (with a sample size of ≥10 patients). (4) Study type: Randomized controlled trials, prospective or retrospective cohort studies, case‑control studies, or case series (with a sample size of ≥10 patients). (5) Publication period: January 2020 to April 2026. (5) Publication period: January 2020 to April 2026. (6) Language: English or Chinese. (6) Language: English or Chinese. 2.3.2 Exclusion criteria. (1) Patients with rotator cuff tears who did not undergo surgical repair (e.g., studies on conservative treatment). (1) Patients with rotator cuff tears who did not undergo surgical repair (e.g., studies on conservative treatment). (2) Patients who underwent concurrent shoulder procedures (e.g., Bankart repair, shoulder arthroplasty, biceps tenodesis). (2) Patients who underwent concurrent shoulder procedures (e.g., Bankart repair, shoulder arthroplasty, biceps tenodesis). (3) Studies that used only MRI or CT for assessment without performing ultrasound examination. (3) Studies that used only MRI or CT for assessment without performing ultrasound examination. (4) Studies that reported ultrasound parameters without any form of association with rehabilitation decisions or functional outcomes. (4) Studies that reported ultrasound parameters without any form of association with rehabilitation decisions or functional outcomes. (5) Studies with ineligible study types: case reports (sample size < 10), reviews, editorials, commentaries, conference abstracts, animal experiments, or in vitro studies. (5) Studies with ineligible study types: case reports (sample size < 10), reviews, editorials, commentaries, conference abstracts, animal experiments, or in vitro studies. 2.4 Literature screening and data extraction Literature screening was performed following the process recommended by the PRISMA 2020 guideline. Duplicate records were first removed using reference management software (NoteExpress). Two investigators independently screened the titles and abstracts against the inclusion criteria and excluded records that clearly did not meet the criteria. Full texts of the potentially eligible articles were then retrieved and independently assessed by the two investigators to make the final decision on inclusion. Data extraction was also performed independently by the two investigators using a pre‑designed data extraction form. The extracted information included (1) basic study characteristics (first author, year of publication, study design); (2) participant characteristics (sample size, tear type and size, postoperative follow‑up time points); (3) musculoskeletal ultrasound parameters (ultrasound device, parameter types: cross‑sectional area, echo intensity, shear wave velocity, strain ratio, etc.); (4) rehabilitation decision‑related information; and (5) level of evidence. After extraction, the two investigators cross‑checked the data to ensure accuracy. Disagreements between reviewers were resolved through discussion, with a third reviewer consulted when necessary. All screening decisions were reached by consensus; however, formal inter-rater agreement statistics (e.g., Cohen's kappa) were not calculated. The characteristics of included studies are summarized in Table 1. 10.1371/journal.pone.0357622.t001Table 1Methodological characteristics of included studies. LOE, level of evidence, graded according to the Oxford Centre for Evidence-Based Medicine (CEBM) levels of evidence.No.First author, yearStudy designSample sizeTear type/sizeFollow-up pointsUltrasound techniqueKey parametersDecision type / relevanceLOE1Itoigawa et al., 2020Prospective cohort60Supraspinatus tearsPreoperative, 1 week, 1–6 monthsB-mode + SWESWV (muscle/tendon)Retear warning2b2He et al., 2021RCT89Small/medium supraspinatusPreoperative, 4, 8, 12, 24 weeksMSUS (B-mode)CSA (muscle)Movement initiation, retear warning1b3Liu et al., 2022Case series45Full/partial tears3 to 4 monthsB-mode + Color DopplerCSA, EIBottleneck ID44Kim et al., 2023Retrospective cohort42Rotator cuff tearPostoperative, > 6 monthsB-mode + Strain ElastographyThickness, fluid, SE scoreLoad adjustment, bottleneck ID3b5Maloof et al., 2023Prospective cohort50Supraspinatus tears8 days, 6, 12 weeks, 6, 12 monthsSWEUSSWV (tendon)Load adjustment, return-to-sport2b6Ye et al., 2024Retrospective cohort39Simple supraspinatus1, 3, 6 monthsB-mode + SWEThickness, width, SWVMovement initiation, load adjustment47Zhu et al., 2024Prospective observational95Mixed tearsPreoperative, 6 monthsMSUS (B-mode)CSA, EIMovement, load, bottleneck ID2b8Solari et al., 2024Prospective cohort48Rotator cuff tear1, 6, 12 weeks, 6, 12 monthsSWESWV (tendon)Load adjustment, return-to-sport2b9Wang et al., 2025Retrospective cohort82Supraspinatus tearPreoperative, 8 daysB-mode + Strain ElastographyThickness, fluid, SE scoreLoad adjustment, return-to-sport410Yan et al., 2025Prospective cohort73Rotator cuff tearPreoperative, 1 week, 1, 3 monthsB-mode + SWETH, CSA, SWVRetear warning, load adjustment2b11Maloof et al., 2025Prospective cohort50Supraspinatus tears8 days, 6, 12 weeks, 6, 12 monthsSWEUSSWV (tendon stiffness)Return-to-sport/work2b Methodological characteristics of included studies. LOE, level of evidence, graded according to the Oxford Centre for Evidence-Based Medicine (CEBM) levels of evidence. 2.5 Risk of bias assessment The methodological quality (risk of bias) of the included studies was independently assessed by two reviewers. The assessment tool was selected according to the study design. For the single randomized controlled trial, the Cochrane Risk of Bias tool version 2 (RoB 2) was used, evaluating bias arising from the randomization process, deviations from intended interventions, missing outcome data, measurement of the outcome, and selective reporting of results. For the nine cohort studies, the Risk of Bias in Non-randomized Studies of Interventions tool version 1 (ROBINS-I) was applied, assessing bias due to confounding, selection of participants, classification of interventions, deviations from intended interventions, missing data, measurement of outcomes, and selective reporting of results. For the one case series, the JBI Critical Appraisal Checklist for Case Series was used. Each study was rated as having either “low risk of bias,” “moderate risk of bias,” “high risk of bias,” or “some concerns.” The two reviewers independently performed the assessment and then cross-checked their results. Disagreements were resolved through discussion, with a third reviewer consulted when necessary. For the single randomized controlled trial included in this review, the Cochrane Risk of Bias tool version 2 (RoB 2) was used; the trial (He et al., 2021) was judged to have low risk of bias across all domains. For the case series included in this review (Liu et al., 2022), the JBI Critical Appraisal Checklist for Case Series was used; the study was judged to have moderate risk of bias. 3 Results 3.1 Study selection The study selection process was reported following the PRISMA 2020 guidelines. The initial search yielded 278 records: 126 from PubMed, 52 from CNKI, and 100 from Wanfang Data. After removing duplicates using NoteExpress, 268 records remained. Screening by title and abstract excluded 221 records, leaving 47 articles for full‑text assessment. Based on the inclusion and exclusion criteria, 36 articles were excluded after full‑text review. Consequently, 11 studies were included in this systematic review. The screening process and its results are presented in a PRISMA flow diagram Figure 1. PRISMA 2020 flow diagram of study selection process. 3.2 Characteristics of included studies The 11 included studies were published between January 2020 and April 2026. In terms of study design, there were six prospective cohort studies, three retrospective cohort studies, one case series, and one randomized controlled trial. Sample sizes ranged from 39 to 95 patients, with a total of 673 participants across the included studies. Postoperative assessment time points ranged from one week to 12 months, with one month, three months, and six months being the most common evaluation points. In terms of ultrasound parameters, six studies focused on tendon parameters (mainly SWV), four studies examined muscle parameters (CSA and EI), and one study reported both types of parameters. Regarding the association with rehabilitation decisions, three studies explored the relationship between ultrasound parameters and the initiation or progression of active movement, seven investigated retear risk warning, four involved prognostic prediction of return to sport, seven addressed load intensity adjustment, and three covered rehabilitation bottleneck identification. 3.3 Summary of ultrasound parameters The included studies primarily reported two categories of ultrasound parameters: muscle morphology parameters (e.g., cross‑sectional area [CSA] of the supraspinatus muscle, used to assess muscle atrophy) and tendon structural parameters (e.g., tendon thickness [TH], shear wave velocity [SWV], used to assess tendon healing quality). A detailed summary of ultrasound equipment and technical specifications is provided in S1 Table. 3.3.1 Tendon parameters. Six studies reported shear wave velocity (SWV) of the supraspinatus tendon. In normally healed tendons, SWV was approximately 6.20 to 6.30 m/s at one week postoperatively, increased to 7.50 m/s at six months, and reached 7.70 to 7.80 m/s at 12 months [20], representing an overall increase of approximately 22% to 25% over 12 months [21]. In the retear group, SWV at one month postoperatively was significantly higher than that in the healed group (P < 0.05), indicating that an abnormally elevated SWV in the early postoperative period may serve as a warning sign for retear risk [22]. Although some studies evaluated conventional ultrasound parameters such as tendon thickness, most found that these parameters were only weakly associated with postoperative functional recovery and had limited clinical utility. For example, Kim et al. (2023) reported that postoperative tendon thickness showed no significant correlation with the KSS function score [16]. Similarly, Solari et al. (2024) found that although tendon thickness recovered to some extent after surgery, the magnitude of change was much smaller than that of SWV and its correlation with functional scores was weak [20], suggesting that conventional parameters are of limited value in rehabilitation monitoring. 3.3.2 Muscle parameters. Four studies reported morphological parameters of the supraspinatus muscle. The CSA on the operated side was significantly smaller than that on the contralateral side at six months postoperatively (P < 0.001), but the degree of CSA improvement (ΔCSA = postoperative CSA − preoperative CSA) was positively correlated with the Constant score (r = 0.633, P < 0.05; 95% CI not reported). The echo intensity (EI) on the operated side was significantly higher than that on the contralateral side at six months (P < 0.05), whereas the degree of EI improvement (ΔEI = preoperative EI − postoperative EI) was also positively correlated with the Constant score (r = 0.693, P < 0.05; 95% CI not reported) [18]. This indicates that greater improvements in CSA and EI (i.e., larger changes from pre- to post-surgery) are associated with better functional recovery. Liu et al. (2022) followed 45 patients at an earlier time point (3–4 months postoperatively) and similarly found that the CSA on the operated side differed significantly from that on the contralateral side, and that the CSA ratio was positively correlated with shoulder forward flexion, external rotation, and the Constant score, further supporting the value of CSA as a rehabilitation monitoring parameter at different postoperative stages [23]. 3.4 Summary of how ultrasound parameters inform rehabilitation decisions 3.4.1 Types of decisions. Based on the available evidence, ultrasound parameters have been associated with five types of rehabilitation decisions. (1) Initiation and progression of active movement. Restoration of tendon SWV to near-normal reference values suggests that it is safe to progress activity. The normal healing trajectory of SWV reported by Solari et al. (from 6.20 m/s at one week to 7.50 m/s at six months) can serve as a reference baseline for clinical judgment of rehabilitation progression [20]. (1) Initiation and progression of active movement. Restoration of tendon SWV to near-normal reference values suggests that it is safe to progress activity. The normal healing trajectory of SWV reported by Solari et al. (from 6.20 m/s at one week to 7.50 m/s at six months) can serve as a reference baseline for clinical judgment of rehabilitation progression [20]. (2) Load intensity adjustment. Maloof et al. found that tendon stiffness at 12 weeks postoperatively was moderately positively correlated with the ability to return to work and sport at 12 months postoperatively (r = 0.49, P = 0.001; 95% CI not reported). Tendon stiffness, measured as shear wave velocity on elastography, reflects the tissue's resistance to deformation and is distinct from the clinical concept of “joint stiffness.” Higher tendon stiffness at 12 weeks was associated with better long-term functional outcomes [10]. This finding suggests that low stiffness may indicate delayed tendon healing. In such patients, premature application of high-intensity loads may increase the risk of retear or delayed healing; therefore, the rehabilitation protocol should be adjusted by reducing load intensity and adopting a more conservative progression strategy. Conversely, patients who reach the target stiffness level can safely and gradually increase training intensity. (2) Load intensity adjustment. Maloof et al. found that tendon stiffness at 12 weeks postoperatively was moderately positively correlated with the ability to return to work and sport at 12 months postoperatively (r = 0.49, P = 0.001; 95% CI not reported). Tendon stiffness, measured as shear wave velocity on elastography, reflects the tissue's resistance to deformation and is distinct from the clinical concept of “joint stiffness.” Higher tendon stiffness at 12 weeks was associated with better long-term functional outcomes [10]. This finding suggests that low stiffness may indicate delayed tendon healing. In such patients, premature application of high-intensity loads may increase the risk of retear or delayed healing; therefore, the rehabilitation protocol should be adjusted by reducing load intensity and adopting a more conservative progression strategy. Conversely, patients who reach the target stiffness level can safely and gradually increase training intensity. (3) Prognostic prediction of return to sport. Tendon stiffness measured at 12 weeks postoperatively is a key prognostic marker that can help identify at an early stage which patients are likely to achieve favorable long-term rehabilitation outcomes (P < 0.001) [10]. (3) Prognostic prediction of return to sport. Tendon stiffness measured at 12 weeks postoperatively is a key prognostic marker that can help identify at an early stage which patients are likely to achieve favorable long-term rehabilitation outcomes (P < 0.001) [10]. (4) Retear risk warning. An abnormally elevated SWV at one month postoperatively suggests that a more conservative rehabilitation strategy is needed. In a prospective cohort study of 60 patients who underwent repair of supraspinatus tendon tears, Itoigawa et al. found that muscle SWE values at one month were significantly higher in the retear group than in the healed group (P < 0.05). Moreover, in the healed group, SWE values at one month were lower than preoperative values and lower than those measured at four to six months, demonstrating a pattern of early decline followed by gradual recovery; however, as the 4- to 6-month values were not directly compared to the preoperative baseline in the original study, a true V-shaped trajectory cannot be confirmed. In contrast, no such recovery pattern was observed in the retear group [22]. These results support the use of SWE measurement at one month as a warning tool for retear risk, with important clinical value for identifying high-risk patients and adjusting rehabilitation protocols in time to avoid injury. (4) Retear risk warning. An abnormally elevated SWV at one month postoperatively suggests that a more conservative rehabilitation strategy is needed. In a prospective cohort study of 60 patients who underwent repair of supraspinatus tendon tears, Itoigawa et al. found that muscle SWE values at one month were significantly higher in the retear group than in the healed group (P < 0.05). Moreover, in the healed group, SWE values at one month were lower than preoperative values and lower than those measured at four to six months, demonstrating a pattern of early decline followed by gradual recovery; however, as the 4- to 6-month values were not directly compared to the preoperative baseline in the original study, a true V-shaped trajectory cannot be confirmed. In contrast, no such recovery pattern was observed in the retear group [22]. These results support the use of SWE measurement at one month as a warning tool for retear risk, with important clinical value for identifying high-risk patients and adjusting rehabilitation protocols in time to avoid injury. (5) Rehabilitation bottleneck identification. Poor recovery of CSA or abnormally elevated EI indicates aggravated muscle atrophy or fatty infiltration, which may require the introduction of adjunctive interventions such as neuromuscular electrical stimulation [18]. (5) Rehabilitation bottleneck identification. Poor recovery of CSA or abnormally elevated EI indicates aggravated muscle atrophy or fatty infiltration, which may require the introduction of adjunctive interventions such as neuromuscular electrical stimulation [18]. 3.4.2 Decision thresholds. Quantifiable decision threshold information is currently limited. Shimizu et al. established age-stratified reference ranges for the strain ratio. At 0° of abduction, the range was 0.72 to 4.17 for patients younger than 50 years and 0.98 to 4.50 for those 50 years or older. A strain ratio exceeding the upper limit suggests abnormally increased passive stiffness of the tendon and calls for adjustment of the rehabilitation protocol [24]. Solari et al. reported that tendon SWV increased progressively after surgery, from 6.20 m/s at one week to 7.50 m/s at six months (P < 0.001). Based on this normal healing trajectory, the authors speculated that a SWV of around 7.50 m/s has been proposed as a potential reference value reflecting postoperative tendon recovery; however, this value has not been validated as a clinical decision threshold [20]. However, this speculation has not yet been validated by prospective studies, and whether 7.50 m/s can serve as a universal reference value remains to be confirmed by further research. Figure 2 Key ultrasound parameters for rehabilitation decision‑making after rotator cuff repair. MSK, musculoskeletal; RCT, randomized controlled trial; SWV, shear wave velocity; CSA, cross‑sectional area; EI, echo intensity. Created by the authors. 3.5 Risk of bias assessment results Among the 11 included studies, five were rated as having low risk of bias (He et al., 2021; Maloof et al., 2023; Zhu et al., 2024; Yan et al., 2025; Maloof et al., 2025), and six were rated as having moderate risk of bias (Itoigawa et al., 2020; Liu et al., 2022; Kim et al., 2023; Ye et al., 2024; Solari et al., 2024; Wang et al., 2025). No study was found to have high risk of bias. The main sources of moderate risk of bias included retrospective study design, inadequate adjustment for confounding factors, and failure to report inter-observer agreement for ultrasound measurements. Fig 3, Fig 4. Risk of bias across ROBINS-I domains for the included cohort studies. Risk of bias assessment of individual cohort studies using the ROBINS-I tool. 4 Discussion 4.1 Summary of main findings This systematic review is the first to focus on the question of how musculoskeletal ultrasound monitoring can inform rehabilitation decision-making after rotator cuff repair. We systematically synthesized evidence from studies published between January 2020 and April 2026. The main findings can be summarized into three points. SWV appears to be the most promising quantitative indicator for rehabilitation decision-making. Multiple studies included in this review consistently showed that changes in SWV correlate well with pain relief and functional recovery. A 2024 Chinese study further reported that the AUC of postoperative SWV for distinguishing rehabilitation outcomes using a Constant-Murley score of 70 as the cutoff was 0.781 (95% CI not reported), whereas the AUCs of tendon thickness and width were only 0.531 and 0.466, respectively [25]. One month and 12 weeks postoperatively are two key decision windows, corresponding respectively to retear risk warning and prognostic prediction of return to sport, and can also serve as a basis for adjusting load intensity. A systematic review by Seth et al. (16 studies, 520 patients) reported that SWV at one month postoperatively was significantly higher in the retear group than in the healed group (P < 0.05), suggesting that SWE measurement at one month may have potential as a warning indicator for retear risk, although predictive modeling was not performed in the primary studies [26]. Ishikawa et al. (2021) provided parallel evidence from the perspective of muscle activity. Using real-time tissue elastography to follow 20 patients after rotator cuff repair, they found that supraspinatus muscle activity increased markedly between six weeks and three months postoperatively, and by three months it had recovered to a level not significantly different from that of healthy controls. This finding independently validates, from the dimension of muscle activity recovery, the reliability of around 12 weeks (i.e., three months) as a key turning point for functional recovery [27], which is consistent with the study by Maloof et al. Muscle morphology parameters (CSA and EI) can serve as quantitative indicators of muscle atrophy and fatty infiltration and can be used to identify patients with a “rehabilitation bottleneck.” Zhu et al. (2024) found that improvements in CSA and EI at six months postoperatively were significantly positively correlated with the Constant score (r = 0.633 and 0.693, respectively), and the combination of the two parameters predicted functional recovery with an AUC of 0.922 (95% CI: 0.848 to 0.967) [18]; however, Umehara et al. (2023) showed that even in the absence of obvious degenerative changes in muscle morphology and composition, the active and passive shear moduli of the supraspinatus muscle remained impaired, suggesting that mechanical properties may be more sensitive rehabilitation monitoring indicators than morphological parameters [28]. It should be noted, however, that the lack of correlation between tendon thickness and functional scores reported by Kim et al. (n = 42) should be interpreted with caution. With a sample size of 42, this study had limited statistical power to detect correlations below approximately r = 0.42 (assuming 80% power at α = 0.05, two-sided). Thus, the null finding cannot be taken as evidence of no association, and larger studies are needed to clarify the clinical relevance of morphological parameters. 4.2 Comparison with existing reviews This review differs from the existing literature in three aspects. First, previous reviews have largely focused on the technical application of ultrasound elastography—for example, a 2023 review summarized the potential of SWE in the diagnosis and monitoring of rotator cuff tears [26], and a 2024 systematic review summarized the role of ultrasound elastography in assessing postoperative retear risk [29]. However, none of these reviews took the quantitative link between ultrasound parameters and rehabilitation decision-making as their core research question. Although Sciarretta et al. (2023) emphasized that “rehabilitation protocols should always be individualized,” they did not address how ultrasound imaging could be used to achieve such individualization [30]. Second, this review is the first to systematically map the complete evidence chain from “ultrasound parameter acquisition” to “rehabilitation decision output,” covering both the types of decisions (initiation and progression of active movement, load intensity adjustment, prognostic prediction of return to sport, retear risk warning and rehabilitation downstaging, and rehabilitation bottleneck identification) and decision thresholds, thereby filling the decision-oriented gap in existing reviews. Men et al. (2025) explicitly stated that “musculoskeletal ultrasound can not only be used for the differential diagnosis of rotator cuff tears but also for evaluating surgical outcomes and guiding rehabilitation at different postoperative stages” [11], which is highly consistent with the perspective of the present review. However, that article is a narrative review rather than a systematic review and did not systematically search for or synthesize evidence specifically related to decision-making. Third, a 2024 Chinese review on “Advances in rehabilitation after rotator cuff surgery” also pointed out that “rehabilitation protocols should be individualized according to the patient's injury and surgical conditions” [31]. However, that review did not address the specific application path of using musculoskeletal ultrasound as a tool for individualization. By systematically synthesizing decision-related examples from primary studies, the present review provides a preliminary evidence framework for translating the concept of “individualized rehabilitation” into the practice of “image-informed precision rehabilitation.” 4.3 Clinical implications: feasibility of constructing an “ultrasound‑informed rehabilitation framework” The value of SWE in informing postoperative rehabilitation advancement has been further substantiated by recent evidence. A systematic review by Lin et al. synthesized data from 11 studies and confirmed that postoperative changes in muscle stiffness, particularly during the 1- to 6-month window, are associated with retear risk and functional recovery, highlighting the potential of sonoelastography to support postoperative monitoring strategies [29]. Complementing this, a prospective cohort study by Yan et al. involving 73 patients demonstrated that SWV at 3 months postoperatively correlated positively with Constant-Murley scores (r = 0.618 to 0.643, P < 0.001), providing direct evidence that quantitative ultrasound parameters can serve as an objective imaging basis for tailoring rehabilitation exercise protocols [17]. Together, these findings provide preliminary support for the concept that ultrasound monitoring may provide objective information to support individualized rehabilitation decision-making. Specifically, the findings of this review support the construction of a precision rehabilitation pathway at three levels. First, at the evidence level. In addition to the dynamic SWV trajectory reported by Solari et al. [20], this judgment has been directly validated clinically. A follow-up study using high-frequency ultrasound and elastography in patients after supraspinatus tendon repair confirmed that SWV has reference value for evaluating pain relief (VAS) and determining rehabilitation outcomes, and may provide clinicians and rehabilitation physicians with additional objective information when developing individualized rehabilitation plans [32]. Second, at the technical level. Musculoskeletal ultrasound is non-invasive, real-time, and reproducible, making it well suited for bedside rehabilitation decision-making. Men et al. (2025) clearly stated that “ultrasound can monitor the repair process of injured tissues and rehabilitation progress in real time during rehabilitation, and by comparing serial images, an individualized rehabilitation protocol can be developed for each patient” [11]. The utility of elastography for assessing tissue biomechanical properties has also been demonstrated in other musculoskeletal conditions, such as plantar fascia assessment in diabetic patients [33]. Third, at the practical level. One study has reported the effect of isokinetic training under musculoskeletal ultrasound monitoring in patients after arthroscopic rotator cuff repair [34], suggesting that ultrasound monitoring can be embedded into routine rehabilitation workflows as an adjunctive tool. That said, it should be noted that the construction of a precision rehabilitation pathway is still in its early stages. A preliminary attempt has been made to integrate ultrasound monitoring into structured rehabilitation workflows, as illustrated by a study on isokinetic training following arthroscopic repair [34]. Nevertheless, most current studies still follow an “observation-correlation” model (i.e., finding statistical associations between ultrasound parameters and functional outcomes) rather than a “measurement-decision” model (i.e., establishing a direct mapping from ultrasound parameters to rehabilitation instructions). In other words, most research to date has remained at the level of “being able to monitor,” and there is still a considerable methodological gap before ultrasound parameters can be prospectively validated as decision-support tools. The integration of ultrasound monitoring into rehabilitation decision-making aligns with broader interdisciplinary approaches in sport and health science, which emphasize the synthesis of physiology, biomechanics, and data analytics to develop personalized rehabilitation strategies [35]. 4.4 Research gaps and future directions 4.4.1 The monitoring value of ultrasound parameters has not been fully exploited in existing RCTs. Saltzman et al. (2017) umbrella review compared the effects of early versus delayed mobilization rehabilitation protocols on pain relief and functional improvement, but it did not involve the use of ultrasound monitoring [36]. He et al. (2021) used CSA as the main outcome measure but did not establish a direct link between specific CSA values and decision boundaries for rehabilitation (e.g., how much CSA recovery is needed to safely progress) [37]. This problem is not an isolated case; it reflects a common shortcoming in the current field. Even in RCT designs, ultrasound parameters are still mainly used as end-point evaluation tools (to determine “which protocol is better”) rather than as real-time decision-guiding tools (to determine “when and how to adjust the protocol”). Future RCTs should embed continuous ultrasound monitoring into the staged decision-making logic of rehabilitation protocols and establish a direct correspondence between ultrasound parameters and rehabilitation instructions. 4.4.2 Integration of patient risk factor stratification with ultrasound‑based decision‑making remains a gap. In a recent review, Parvizi et al. (2025) reported that the retear rate after rotator cuff repair ranges from 15% to 21%, with risk factors including advanced age, large tear size, poor tissue quality, high activity level, and comorbidities such as diabetes and hyperlipidemia [8]. In 2024, Chen et al., in a prospective study of 89 patients, showed that the preoperative supraspinatus tendon SWV ratio (SWV-RT) was significantly negatively correlated with the arthroscopic remnant tendon quality score (r = −0.722 to −0.884, P < 0.001); that is, a lower preoperative SWV indicated poorer intraoperative remnant tendon quality. Based on this finding, the authors suggested that SWE can be used to preoperatively predict remnant tendon quality [38], implying that patients with low preoperative SWV theoretically belong to a “high-risk group” with weaker postoperative healing capacity. However, in current clinical practice, whether patients with different anatomical risk profiles should receive differentiated postoperative rehabilitation progression and intensity (e.g., whether a more conservative SWV decision threshold should be set for patients with poor remnant tendon quality) remains an open question. Although RCTs have explored the effects of different rehabilitation protocols on supraspinatus muscle morphology after rotator cuff repair—for example, He et al. (2021) conducted an RCT (n = 89) comparing informed rehabilitation with conventional rehabilitation on supraspinatus CSA and found that the informed group had superior CSA at all postoperative time points (P < 0.05), with no significant difference in retear rates between the two groups (P > 0.05) [37]—that study did not answer a more critical question: whether patients with different baseline characteristics (e.g., stratified by baseline CSA, age, or tear size) show heterogeneous responses to the same rehabilitation protocol. In clinical practice, even when a patient has multiple high-risk factors for retear (e.g., a massive tear combined with diabetes), the rehabilitation plan is still based mainly on postoperative SWV values rather than on risk factor-stratified preventive strategies. An integrated closed loop combining risk factor stratification with ultrasound parameter monitoring has not yet been established: whether high-risk patients should be assigned more conservative SWV decision thresholds (e.g., allowing progression only when SWV reaches a certain value at six weeks) remains an untested hypothesis. Future RCTs should incorporate risk factor stratification designs, randomizing patients to either an “integrated SWV plus risk factor” group or a “SWV-only” group, to determine whether integrating risk factors can further improve rehabilitation precision and reduce retear rates in high-risk populations. 4.4.3 Lack of standardized parameters and decision thresholds. Currently, the ultrasound equipment, transducer frequencies, measurement sites, and region-of-interest (ROI) settings vary considerably across studies, making it difficult to directly compare absolute SWV values between different centers. Moreover, there is a lack of threshold studies oriented toward clinical decision-making—for example, what SWV value would safely allow initiation of active resistance training, or how much CSA reduction would warrant the introduction of electrical stimulation intervention. The age-stratified strain ratio reference ranges established by Shimizu et al. (2023) based on healthy individuals represent an important attempt, but the sample size was small and the clinical decision validity still requires validation in larger samples [24]. Future multicenter collaborative studies are needed to establish standardized ultrasound measurement protocols and a database of clinical outcome-based decision thresholds. 4.4.4 Long‑term follow‑up data are lacking. Most included studies had follow-up periods of only six to twelve months, and there is a lack of systematic tracking of long-term tendon healing status, functional maintenance, and retear risk beyond one year postoperatively. Of note, RCT-level long-term follow-up studies have already been able to identify structural “residual deficits.” Kjær et al. (2024) performed ultrasound follow-up at one year in 79 patients from the CUT-N-MOVE trial and found that even when rehabilitation was initiated as early as the second postoperative week (compared with the traditional sixth week), the repaired supraspinatus tendon remained significantly thinner than the contralateral side (P < 0.001), and muscle thickness was also significantly reduced in the retear subgroup [39]. This high-level evidence indicates that differences in current rehabilitation protocols (early vs. late mobilization) are insufficient to reverse long-term structural deficits, suggesting that the bottleneck for long-term recovery may lie beyond the scope of existing study designs. Future prospective cohort studies of at least two to five years are needed to determine whether the structural deficits observed at one year persist into the second to fifth years and whether they affect the success rate of return to sport. 4.4.5 The biomechanical basis of ultrasound parameters requires further investigation. Among the studies included in this review, the causal mechanisms linking biomechanical parameters of tendons and muscles to clinical functional outcomes remain unclear. Umehara et al. (2023) showed that even in the absence of obvious degenerative changes in muscle morphology and composition, the active and passive shear moduli of the supraspinatus muscle remained impaired, suggesting that mechanical properties may be more sensitive rehabilitation monitoring indicators than morphological parameters [28]. This suggests that future research should shift from merely morphological assessment to a multidimensional monitoring framework that integrates mechanical properties, morphology, and function. 4.4.6 Emerging technologies and decision-support tools. Beyond parameter standardization, emerging technologies such as artificial intelligence (AI) and large language models have shown promise in clinical decision support. Recent studies have explored the application of AI-based tools in delivering guideline-compliant recommendations for musculoskeletal pain management [40] and in comparative evaluations of AI models for clinical scenarios [41]. These approaches may offer new opportunities for integrating serial ultrasound data into rehabilitation decision-making, though their validation in the postoperative rotator cuff population remains an area for future investigation. 4.5 Limitations of this review This review has several limitations. First, the included studies were mainly observational, with a lack of large-scale randomized controlled trials, resulting in an overall low level of evidence. Moreover, some of the included studies were case series, which cannot provide dynamic change data, potentially compromising the completeness of the evidence. Second, there was considerable heterogeneity across studies in ultrasound parameter definitions, measurement methods, and follow-up time points, which precluded a meta-analysis and limited the synthesis to a narrative summary. Of note, in the measurement of muscle morphology parameters, the choice of region of interest (ROI) is an important source of heterogeneity. Yuri et al. (2021) specifically addressed this issue by comparing the sensitivity of three different measurement ranges (anterior region, anterior-middle posterior region, and whole cross-sectional area) of the supraspinatus muscle using real-time tissue elastography. They found that the whole cross-sectional area had the highest sensitivity (81.5%) and the best intraclass correlation coefficient (ICC, 0.92 to 0.99) [42]. This quantitative evidence provides a specific operational pathway to resolve the “non-standardized measurement range” issue identified in this review: future studies reporting muscle morphology parameters such as CSA should preferentially adopt the whole cross-sectional area as the standardized measurement range. In addition, although the screening and data extraction were performed independently by two reviewers, formal inter-rater agreement statistics were not calculated, which may limit the reproducibility assessment of the selection process. Third, in terms of sample size, the included studies had sample sizes ranging from 39 to 95 (total 673 participants), with considerable variation between studies, which may have some impact on the comparability of results. Fourth, gray literature and unpublished studies were not included, so there may be potential publication bias. It is worth noting that during the literature screening process, one relevant master's thesis, titled “Application of musculoskeletal ultrasound after rotator cuff repair,” met the inclusion criteria but was excluded because the publication type was restricted to journal articles [43,44]. That thesis pointed out that the retear rate after rotator cuff repair is high, but clinical diagnosis is difficult; although MRI is the gold standard, it is expensive, and therefore musculoskeletal ultrasound can serve as a low-cost, efficient adjunctive examination method to provide a basis for patients’ next-step treatment. Excluding such gray literature ensures a quality benchmark based on peer-reviewed publications, but it may also lead to the omission of high-quality negative results or exploratory findings. Therefore, caution should be exercised when generalizing the conclusions of this review. Fifth, despite optimization of the search strategy, some relevant studies may still have been missed, particularly those in languages other than English or Chinese. Sixth, the risk of bias assessment revealed that among the 11 included studies, six were rated as having moderate risk of bias and five as having low risk of bias. Although no study was judged to have high risk of bias, the proportion of studies with moderate risk of bias was relatively high. Their limitations mainly involved retrospective design, inadequate control of confounding factors, and failure to report measurement consistency in some studies. These factors may have some impact on the overall strength of the evidence, and therefore the conclusions of this review should be interpreted with caution. Despite these limitations, this review is the first to systematically focus on the integration of evidence on “musculoskeletal ultrasound monitoring to inform rehabilitation decision-making after rotator cuff repair,” and it provides a valuable reference framework for future research directions and clinical practice translation in this field. 5 Conclusion This systematic review is the first to synthesize the evidence on the use of musculoskeletal ultrasound monitoring to inform rehabilitation decision-making after rotator cuff repair. The available evidence indicates that ultrasound parameters such as shear wave velocity (SWV), cross-sectional area (CSA), and echo intensity (EI) are associated with initiation of active movement, load adjustment, prognostic prediction of return to sport, and retear risk warning. Among these, SWV appears to be the most promising quantitative indicator, with one month and 12 weeks postoperatively being the key decision windows. Clinical implications: The synthesized evidence suggests that SWV, CSA, and EI are promising parameters for monitoring tendon healing and muscle recovery after rotator cuff repair. However, specific numerical thresholds for clinical decision-making have not been validated in the included studies. Their use should be confined to research settings until prospective trials establish their validity. Future studies should focus on standardizing measurement protocols and validating parameter-based decision thresholds. Research recommendations: Future multicenter randomized controlled trials are needed to verify the superiority of ultrasound-informed rehabilitation over traditional rehabilitation, to establish standardized ultrasound measurement protocols and a database of clinical outcome-based decision thresholds, and to extend follow-up to at least 2 years in order to clarify long-term prognosis. Supporting information Detailed methodological characteristics of included studies. (DOCX) Highlights. (DOCX) Search strategy. (DOCX) PRISMA 2020 checklist. (DOCX) 28 Jul 2026 Dear Dr. SHI, Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process. Please submit your revised manuscript by Sep 26 2026 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org. When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file. A letter that responds to each point raised by the academic editor and reviewer(s). You should upload this letter as a separate file labeled 'Response to Reviewers'. A letter that responds to each point raised by the academic editor and reviewer(s). You should upload this letter as a separate file labeled 'Response to Reviewers'. A marked-up copy of your manuscript that highlights changes made to the original version. You should upload this as a separate file labeled 'Revised Manuscript with Track Changes'. A marked-up copy of your manuscript that highlights changes made to the original version. You should upload this as a separate file labeled 'Revised Manuscript with Track Changes'. An unmarked version of your revised paper without tracked changes. You should upload this as a separate file labeled 'Manuscript'. An unmarked version of your revised paper without tracked changes. You should upload this as a separate file labeled 'Manuscript'. If you would like to make changes to your financial disclosure, please include your updated statement in your cover letter. Guidelines for resubmitting your figure files are available below the reviewer comments at the end of this letter. If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: https://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols. Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-email&utm_source=authorletters&utm_campaign=protocols. As the corresponding author, your ORCID iD is verified in the submission system and will appear in the published article. PLOS supports the use of ORCID, and we encourage all coauthors to register for an ORCID iD and use it as well. Please encourage your coauthors to verify their ORCID iD within the submission system before final acceptance, as unverified ORCID iDs will not appear in the published article. Only the individual author can complete the verification step; PLOS staff cannot verify ORCID iDs on behalf of authors. We look forward to receiving your revised manuscript. Kind regards, Wencai Liu Academic Editor PLOS One Journal Requirements: When submitting your revision, we need you to address these additional requirements. 1. Please ensure that your manuscript meets PLOS ONE's style requirements, including those for file naming. The PLOS ONE style templates can be found at https://journals.plos.org/plosone/s/file?id=wjVg/PLOSOne_formatting_sample_main_body.pdf and https://journals.plos.org/plosone/s/file?id=ba62/PLOSOne_formatting_sample_title_authors_affiliations.pdf 2. Please ensure that you have uploaded your PRISMA flowchart as Figure 1, or else explain why this is not possible. Blank flowcharts can be found here: http://www.prisma-statement.org/ 3. Please update your submission to use the PLOS LaTeX template. The template and more information on our requirements for LaTeX submissions can be found at http://journals.plos.org/plosone/s/latex. 4. We note that the grant information you provided in the ‘Funding Information’ and ‘Financial Disclosure’ sections do not match. When you resubmit, please ensure that you provide the correct grant numbers for the awards you received for your study in the ‘Funding Information’ section. 5. Please note that funding information should not appear in any section or other areas of your manuscript. We will only publish funding information present in the Funding Statement section of the online submission form. Please remove any funding-related text from the manuscript. 6. Please provide a complete Data Availability Statement in the submission form, ensuring you include all necessary access information or a reason for why you are unable to make your data freely accessible. If your research concerns only data provided within your submission, please write "All data are in the manuscript and/or supporting information files" as your Data Availability Statement. 7. PLOS requires an ORCID iD for the corresponding author in Editorial Manager on papers submitted after December 6th, 2016. Please ensure that you have an ORCID iD and that it is validated in Editorial Manager. To do this, go to ‘Update my Information’ (in the upper left-hand corner of the main menu), and click on the Fetch/Validate link next to the ORCID field. This will take you to the ORCID site and allow you to create a new iD or authenticate a pre-existing iD in Editorial Manager. 8. We note that Figure 2 in your submission contain copyrighted images. All PLOS content is published under the Creative Commons Attribution License (CC BY 4.0), which means that the manuscript, images, and Supporting Information files will be freely available online, and any third party is permitted to access, download, copy, distribute, and use these materials in any way, even commercially, with proper attribution. For more information, see our copyright guidelines: http://journals.plos.org/plosone/s/licenses-and-copyright. We require you to either (1) present written permission from the copyright holder to publish these figures specifically under the CC BY 4.0 license, or (2) remove the figures from your submission: 1. You may seek permission from the original copyright holder of Figure 2 to publish the content specifically under the CC BY 4.0 license. We recommend that you contact the original copyright holder with the Content Permission Form (http://journals.plos.org/plosone/s/file?id=7c09/content-permission-form.pdf) and the following text: “I request permission for the open-access journal PLOS ONE to publish XXX under the Creative Commons Attribution License (CCAL) CC BY 4.0 (http://creativecommons.org/licenses/by/4.0/). Please be aware that this license allows unrestricted use and distribution, even commercially, by third parties. Please reply and provide explicit written permission to publish XXX under a CC BY license and complete the attached form.” Please upload the completed Content Permission Form or other proof of granted permissions as an "Other" file with your submission. In the figure caption of the copyrighted figure, please include the following text: “Reprinted from [ref] under a CC BY license, with permission from [name of publisher], original copyright [original copyright year].” 2. If you are unable to obtain permission from the original copyright holder to publish these figures under the CC BY 4.0 license or if the copyright holder’s requirements are incompatible with the CC BY 4.0 license, please either i) remove the figure or ii) supply a replacement figure that complies with the CC BY 4.0 license. Please check copyright information on all replacement figures and update the figure caption with source information. If applicable, please specify in the figure caption text when a figure is similar but not identical to the original image and is therefore for illustrative purposes only. 9. Please remove your figures from within your manuscript file, leaving only the individual TIFF/EPS image files, uploaded separately. These will be automatically included in the reviewers’ PDF. 10. Please include a new copy of Table 1 in your manuscript; the current table is difficult to read. Please follow the link for more information: https://journals.plos.org/plosone/s/tables 11. Please include captions for your Supporting Information files at the end of your manuscript, and update any in-text citations to match accordingly. Please see our Supporting Information guidelines for more information: http://journals.plos.org/plosone/s/supporting-information. 12. If the reviewer comments include a recommendation to cite specific previously published works, please review and evaluate these publications to determine whether they are relevant and should be cited. There is no requirement to cite these works unless the editor has indicated otherwise. [Note: HTML markup is below. Please do not edit.] Reviewers' comments: Reviewer's Responses to Questions Comments to the Author 1. Is the manuscript technically sound, and do the data support the conclusions? Reviewer #1: Yes Reviewer #2: Yes Reviewer #3: Partly ********** 2. Has the statistical analysis been performed appropriately and rigorously? -->?> Reviewer #1: Yes Reviewer #2: N/A Reviewer #3: No ********** 3. Have the authors made all data underlying the findings in their manuscript fully available??> The PLOS Data policy Reviewer #1: Yes Reviewer #2: Yes Reviewer #3: Yes ********** 4. Is the manuscript presented in an intelligible fashion and written in standard English??> Reviewer #1: Yes Reviewer #2: Yes Reviewer #3: Yes ********** Reviewer #1: Summary Assessment This systematic review addresses a genuinely useful and currently underserved question, namely whether musculoskeletal ultrasound parameters can be translated into concrete rehabilitation decisions after rotator cuff repair rather than being used merely as monitoring tools. The manuscript is built on a registered PROSPERO protocol, follows the PRISMA 2020 framework with arithmetic that checks out from search to inclusion, and appropriately abstains from meta-analysis given the heterogeneity of measurement methods and follow-up windows across the eleven included studies, a decision that sits comfortably with the guidance on narrative synthesis given in the established primer on systematic review and meta-analysis methodology. The clinical framing around shear wave velocity, cross-sectional area and echo intensity is coherent, and the proposed decision windows at one month and twelve weeks postoperatively are a genuine contribution to a field that has so far mostly monitored rather than decided. At the same time, the manuscript carries a cluster of internal inconsistencies that a careful reader will notice immediately: a risk-of-bias figure pair that visually reports a tool different from the one described in the Methods, a participant count that does not reconcile with the sum of the individual study sample sizes, a sample size quoted twice for the same trial with two different values, a duplicated reference, and a citation pairing that attributes two unrelated works to a single author. None of these are fatal to the underlying scientific contribution, but each needs to be resolved before the manuscript can be considered internally consistent, and the introduction in particular relies in several places on unreferenced assertions that would benefit from the additional support suggested below. Strengths The PRISMA flow arithmetic is fully consistent throughout: 126 PubMed, 52 CNKI and 100 Wanfang records sum correctly to the stated 278 identified records, the reduction to 268 after removing 10 duplicates is correct, the drop to 47 full-text assessments after excluding 221 at the screening stage is correct, and the final count of 11 included studies after excluding 36 (19 ineligible study type, 13 with no association to rehabilitation or functional outcomes, 1 involving other shoulder surgeries, 3 for other reasons, summing to 36) is internally coherent with Figure 1. The decision not to pool data statistically, given the marked heterogeneity in ultrasound parameters, region-of-interest definitions and follow-up time points across studies, is the methodologically honest choice and is consistent with established guidance on when narrative synthesis is preferable to forced quantitative pooling. The three-tool risk-of-bias strategy, RoB 2 for the single randomized trial, ROBINS-I for the nine cohort studies and the JBI checklist for the one case series, is an appropriate match of tool to study design, and the clinical translation into five decision categories (movement initiation, load adjustment, return-to-sport prognosis, retear warning, bottleneck identification) gives the review a genuinely actionable structure that most prior narrative pieces on this topic lack. The discussion is candid about the field's current ceiling: it correctly distinguishes an observation-correlation evidence base from a measurement-decision one, and it does not overstate what eleven heterogeneous, mostly observational studies can support. Critical Issues The risk-of-bias visual summary does not match the stated methodology. Section 2.5 (page bearing lines 217 to 231) states explicitly that ROBINS-I was applied to the nine non-randomized cohort studies, yet Figures 3 and 4 present the classic seven-domain Cochrane RoB 1 structure built for randomized trials, including random sequence generation and allocation concealment, domains that are conceptually meaningless for non-randomized cohorts and do not correspond to any of the seven ROBINS-I domains (confounding, participant selection, intervention classification, deviations from intended interventions, missing data, outcome measurement, selective reporting). This is not a labeling nuance; it means the two risk-of-bias figures currently describe a tool that was not used on these studies. The figures need to be regenerated with the correct ROBINS-I domain headings, or the legend needs to explain, convincingly, why RoB 1 language was retained. The reported total sample size does not reconcile with Table 1 (line 741 area). The eleven individual sample sizes listed in the table (60, 89, 45, 42, 50, 39, 95, 40, 82, 73, 50) sum to 665, not the 673 stated in section 3.2 (line 245). An eight-participant discrepancy of this kind is exactly the sort of arithmetic slip that a careful line-by-line audit is meant to catch, and it should be corrected either in the table or in the narrative count, whichever is accurate. The sample size for He and colleagues' 2021 randomized trial is given twice with two different values. Table 1 lists this study with a sample size of 89, while section 4.4.2 of the Discussion (line 479) states explicitly that “He et al. (2021) conducted an RCT (n = 81).” Only one of these figures can be correct, and since this is the review's sole randomized trial and therefore carries disproportionate methodological weight, the discrepancy should be resolved against the source publication before submission. References 7 and 8 (page bearing lines 620 to 625) are duplicates. Both entries read identically, same authors, same title (“Value of ultrasound in postoperative evaluation of minimally invasive treatment of rotator cuff tears”), same journal, volume, issue and page range, yet they are cited together in the introduction (line 111) as if they were two independent supporting sources. This artificially doubles the apparent evidentiary weight behind that sentence and should be corrected to a single citation. The citation pairing at references 31 and 32 (lines 700 to 705) misattributes authorship. The Discussion, section 4.3 (line 418), presents a claim as belonging to “Xu et al. (2024)” and supports it with the joint citation [31,32], but reference 32 is a 2022 master's thesis by a different author (Hu MX), not a second Xu publication. As written, the text implies Hu's 2022 work is part of the same 2024 study, which is not accurate; the two sources should be cited and attributed separately. One sentence in section 4.4.5 (line 530) appears to be a fragment left over from another manuscript. The passage “Our review complements a recently published protocol in this journal (referring to LIPUS-related work), extending the evidence from treatment to assessment-guided decision-making” introduces low-intensity pulsed ultrasound, a term that appears nowhere else in the paper, without a citation and without any prior mention of a companion protocol. This sentence either needs a proper citation and integration into the argument, or it should be removed. The extraction and risk-of-bias procedures rely on two independent reviewers who “cross-checked” their results (lines 208 and 229), but no inter-rater agreement statistic, such as Cohen's kappa or a simple percentage agreement, is reported for either the title and abstract screening stage, the full-text eligibility stage, or the risk-of-bias judgments themselves. Asserting that two raters agreed, without giving the number that demonstrates it, sits in the same category as citing another group's reliability coefficient in place of testing agreement in one's own material; the manuscript should report the actual agreement statistics it presumably already has. None of the eleven included studies is characterized, even in summary form, on whether it established its own measurement reliability (intraclass correlation, standard error of measurement, minimal detectable change) for the ultrasound parameters in its own operators and patient cohort, as opposed to citing a reliability figure obtained in an unrelated population. This distinction matters here: the elastography intraclass correlation of 0.92 to 0.99 attributed to Yuri and colleagues in section 4.5 (line 545) was obtained for supraspinatus region-of-interest selection in a different clinical context, and a coefficient established elsewhere cannot be assumed to transfer to a different set of operators, machines and postoperative shoulders. A short additional column in Table 1 indicating whether each primary study reported its own test-retest or inter-operator reliability data in its own sample would materially strengthen the review's ability to judge measurement trustworthiness. None of the quantitative findings summarized from the eleven studies, the twenty-two to twenty-five percent shear wave velocity increase, the 0.949 area under the curve, the 91.70 percent sensitivity, the various correlation coefficients, is accompanied anywhere in the manuscript by a confidence interval. Point estimates alone, particularly from studies with sample sizes between 39 and 95, give the reader no sense of the precision behind numbers that are then proposed as candidate clinical thresholds, for instance the suggestion in the Conclusion (line 590) that a shear wave velocity below 7.0 m/s at three months should trigger protocol adjustment. At minimum, the primary quantitative claims carried forward into the Conclusion's clinical recommendations should be reported with their confidence intervals where these are available in the source studies. No a priori sample size or power justification is reported for any of the eleven primary studies, and this matters because several of the reported associations sit close to what these sample sizes can reliably detect. Recomputing the minimum correlation each study could detect with 80 percent power at a two-sided alpha of 0.05 gives approximately r = 0.44 for a sample of 39, r = 0.42 for 42, r = 0.39 for 50, and r = 0.28 for 95. The strong correlations reported by Zhu and colleagues (r = 0.633 and r = 0.693, n = 95, line 283) and by Maloof and colleagues (r = 0.49, n = 50, line 303) comfortably clear these thresholds and are not in question. However, the negative finding reported by Kim and colleagues, that postoperative tendon thickness showed no significant correlation with the KSS function score in a sample of 42 (line 270), cannot be interpreted as evidence of absence: with only 42 participants, that study was underpowered to detect anything below a moderate correlation of roughly 0.42, so the null result is at least as consistent with an underpowered test as with a true absence of association. The Discussion should qualify this specific null finding accordingly rather than presenting it as settling the question of tendon thickness's clinical relevance. Important Additions Required A supplementary table listing, for each of the eleven included studies, the ultrasound system manufacturer, model, country of manufacture, transducer frequency and a validation reference for the technique used would directly address the heterogeneity that section 4.4.3 (line 495) already acknowledges in prose but never actually tabulates; without this information a reader cannot judge how comparable the absolute shear wave velocity values reported across studies actually are. The review would benefit from an explicit certainty-of-evidence statement, using GRADE or an equivalent framework, for each of the five decision categories (movement initiation, load adjustment, return-to-sport prognosis, retear warning, bottleneck identification), rather than relying solely on the Oxford level-of-evidence column already present in Table 1. Given that six of the eleven studies were judged to carry moderate risk of bias, that no meta-analysis was possible, and that sample sizes throughout are modest, an explicit downgrading discussion covering imprecision, inconsistency and indirectness would let readers calibrate how much confidence the proposed decision thresholds actually deserve. The PROSPERO registration number given (CRD420261418165, line 163) contains fifteen characters, one more than the fourteen-character format, the fixed CRD42 prefix followed by nine digits, used by standard PROSPERO identifiers. The authors should re-verify this number against their registration confirmation before publication, since a transcription error here would undermine an otherwise valuable piece of methodological transparency. Minor Corrections The header row of Table 1 (line 741 area) contains the compressed label “Tear typesize,” which should read “Tear type/size.” The Limitations section (lines 563 to 578) contains a near-duplicate sentence, “Excluding such gray literature ensures a quality benchmark based on peer-reviewed publications, but it may also lead to the omission of high-quality negative results or exploratory findings,” which is restated almost verbatim two sentences later as “This exclusion may have omitted exploratory findings, but ensured a quality benchmark based on peer-reviewed publications.” One of the two should be removed. In the introduction (line 100), the parenthetical aside built around a long dash, “a finding that suggests postoperative rehabilitation decisions should not be guided solely by the goal of absolute prevention of retears,” reads more clearly as two complete sentences separated by a period. The same construction recurs at lines 300 to 302 around the definition of tendon stiffness; breaking this into a short standalone explanatory sentence would also improve readability there. Decimal and Formatting Verification Measurement values throughout the shear wave velocity and strain ratio reporting are frequently given to only one decimal place (6.2 m/s, 7.5 m/s, 0.72 to 4.17), whereas the correlation coefficients and areas under the curve elsewhere in the same manuscript are given to three (0.633, 0.949). Bringing the velocity and ratio values to a consistent two-decimal minimum, 6.20 m/s, 7.50 m/s, would match the precision implied by shear wave elastography measurement and remove the visual impression of inconsistent rigor between sections. The period is used correctly as the decimal separator throughout, and range values in the narrative text mostly use “to” appropriately, for example “15% to 21%,” “−0.722 to −0.884,” though several other ranges still use an en dash (6.2–6.3 m/s, 0.72–4.17) and should be brought into line with the same convention for consistency. Suggested References with Placement Rationale The introduction currently opens with the unreferenced assertion that “rotator cuff tear is one of the most common musculoskeletal disorders” (line 84). Oliva, Osti, Padulo and Maffulli's epidemiological study on rotator cuff tear incidence would directly support this prevalence claim and would anchor the opening sentence in a citable source rather than leaving it as an assumed fact. The following sentence, that arthroscopic repair is “the mainstream surgical treatment for symptomatic full-thickness tears” (lines 85 to 86), is likewise unreferenced. The I.S.Mu.L.T. Rotator Cuff Tears Guidelines, authored by Oliva, Piccirilli, Bossa and colleagues including Padulo, is precisely the kind of consensus guideline document this claim needs, since it establishes arthroscopic repair's standing within a structured clinical recommendation rather than a single primary study. Section 1.1 asserts, again without a citation, that rehabilitation “must balance two conflicting needs” between protective immobilization and early mobilization (lines 91 to 93). Poku, Hassan, Migliorini and Maffulli's systematic review and meta-analysis on hydrodilatation in frozen shoulder illustrates this same immobilization-versus-mobilization tension in a closely related shoulder condition and would give the sentence external grounding drawn from rigorous systematic review methodology rather than leaving it as an editorial statement. The transitional sentence introducing elastography's “important progress in the preoperative evaluation of rotator cuff tears” (lines 121 to 122) similarly lacks a reference of its own, sitting between two cited sentences without support. Santoboni and colleagues' study correlating ultrasonographic and elastosonographic parameters of the plantar fascia demonstrates the same quantitative elastographic correlate approach being validated in a different musculoskeletal tissue, and would support the general claim of elastography's expanding evidence base without duplicating the Zhang et al. citation that immediately follows. In the Discussion, the research gaps discussion around tendon healing monitoring, section 4.4 (following the review's own point that ultrasound parameters remain end-point rather than decision-guiding tools), would be strengthened by Hassan, Poku, Miah and Maffulli's systematic review of high-volume injections in Achilles tendinopathy, which offers a parallel example of a tendon-healing systematic review confronting the same evidence-to-decision translation gap this manuscript identifies for the rotator cuff. Finally, the clinical implications section, 4.3, where the manuscript argues for an interdisciplinary “ustrasound-guided precision rehabilitation pathway,” would benefit from Padulo's own methodological commentary on interdisciplinary approaches in sport and health science, which speaks directly to the translational framing the authors are building toward without repeating content already covered by the orthopedic-specific citations above. Overall Recommendation Major revision. The clinical question is worthwhile, the search and inclusion process is transparent and arithmetically sound, and the decision not to force a meta-analysis onto heterogeneous data is the right call. Before this can move forward, however, the authors need to reconcile the risk-of-bias figures with the tool actually described in the Methods, correct the sample-size discrepancies in Table 1 and in the He et al. description, remove the duplicated and misattributed references, add the missing inter-rater agreement statistics, and temper the interpretation of underpowered null findings. None of these corrections require new data collection; they require careful reconciliation of what is already in the manuscript, and once addressed the review would represent a genuinely useful synthesis for clinicians managing postoperative rehabilitation after rotator cuff repair. Suggested References (Full Citation Details) Oliva F, Osti L, Padulo J, Maffulli N. Epidemiology of the rotator cuff tears: a new incidence related to thyroid disease. Muscles Ligaments Tendons J. 2014;4(3):309-314. Oliva F, Piccirilli E, Bossa M, Via AG, Colombo A, Chillemi C, Gasparre G, Pellicciari L, Franceschetti E, Rugiero C, Scialdoni A, Vittadini F, Brancaccio P, Creta D, Buono AD, Garofalo R, Franceschi F, Frizziero A, Mahmoud A, Merolla G, Nicoletti S, Spoliti M, Osti L, Padulo J, Portinaro N, Tajana G, Castagna A, Foti C, Masiero S, Porcellini G, Tarantino U, Maffulli N. I.S.Mu.L.T. Rotator Cuff Tears Guidelines. Muscles Ligaments Tendons J. 2016;5(4):227-263. Santoboni F, Michelini S, Vetrano M, Nusca SM, Latini E, Vulpiani MC, et al. Correlates of the Ultrasonographic and Elastosonographic Parameters of the Plantar Fascia in Patients with Type 2 Diabetes. Muscles Ligaments Tendons J. 2023;13(1):109-118. Padulo J. Sport and health science: interdisciplinary approaches to modern challenges. Br Med Bull. 2025;155(1):ldaf007. Reviewer #2: 1. Misalignment between research question and available evidence. The stated aim is to determine “which ultrasound parameters … have been used to guide adjustments of rehabilitation protocols.” Yet the 11 included papers predominantly report statistical associations between MSUS parameters and functional scores (e.g., Constant, ASES). They do not describe interventional studies where ultrasound findings triggered a change in the rehab protocol. The conclusion that MSUS “can guide the initiation of active movement, adjustment of exercise load…” is therefore not supported by the included evidence. 2.Zhao XQ et al. 2025 appears identically as references [7] and [8]. 3.The master’s thesis (Xie Y, ref [40]) and conference paper (Xu M, ref [31]) are excluded from the synthesis yet are cited in the discussion as supportive evidence. 4.In the abbreviation list, KSS is defined as “Knee Society Score (used in one included study for function assessment)” - an obvious copy‑paste mistake for a shoulder study. 5.In section 4.4.1, Saltzman et al. is called a “2023 umbrella review”, but reference [35] is the 2017 paper. 6.Seth et al. (2023, ref [25]) is said to confirm 1‑month SWV as predictor; the original paper reported significance but explicitly stated no predictive modelling was done. 7.Maloof et al. 2023 and Maloof et al. 2025 may represent overlapping cohorts but are treated as separate studies. 8.The closing clinical recommendation states: “When SWV deviates from the normal healing trajectory (e.g., <7.0 m/s at 3 months or <7.5 m/s at 6 months) or when the CSA difference from the contralateral side exceeds 20%, timely adjustment … is advised.” Neither the 7.0/7.5 m/s values nor the 20% CSA cut‑off are reported by any included primary study. These are author inventions. Requirement: Delete these thresholds or explicitly label them as untested hypotheses requiring prospective validation. 9.Title page lists “Ying SHI, Chuanxiong LI, Yi BAO”; main text lists “Ying Shi, Yi Bao, Chuanxiong Li*”. Inconsistent. 10.The LOE (level of evidence) column in Table 1 uses 1b/2b/3b/4 without stating the grading system (presumably Oxford CEBM) – define it. 10.Replace “guide rehabilitation decision‑making” with “association with rehabilitation decision points” in title, abstract, and headings. 11."While not directly within the scope of rotator cuff repair, Dong et al. (Eur J Radiol, 2026) provide a useful methodological parallel in demonstrating how imaging-based muscle morphology assessment can inform rehabilitation evaluation. The authors may consider citing this work when discussing the broader landscape of imaging-guided rehabilitation assessment in Section 1.2." 12."The potential role of AI/Large language model in rehabilitation decision-making" - this cutting-edge perspective should be addressed in the future outlook section of the review.It is suggested that these studies be cited to support your argument(PMID: 40597769,PMID: 40952435). Reviewer #3: This authors present a review about using musculoskeletal ultrasound to guide rehabilitation decisions after rotator cuff repair. The authors synthesize evidence from 11 studies and propose an "ultrasound-guided precision rehabilitation" framework.This review is logically structured and analyzes cases from multiple perspectives. However, significant concerns arise regarding methodological rigor, the strength of evidence supporting clinical recommendations, data presentation, and logical coherence in the discussion. The conclusions, particularly the proposed clinical decision thresholds, are not sufficiently supported by the available evidence. My questions are attached below: 1. Why only analyze the literature from PubMed, CNKI and Wanfang, which may cause analysis bias? A review that aims to synthesize general evidence should ideally include major international databases such as Web of Science. Furthermore, the exclusion of gray literature and trial registries should be justified. Please explain why these sources were omitted and discuss the potential impact on the completeness of your evidence synthesis. 2. In Section 3.4.1, the authors conclude that the healed group showed a "first decrease, then increase" healing trajectory based on the observations that SWV at 1 month was lower than both preoperative values and 4–6‑month values. However, this conclusion is logically flawed. To establish a true "decrease‑then‑increase" (V‑shaped) trajectory, it is essential to demonstrate that the 4–6‑month SWV has returned to a level equal to or higher than the preoperative baseline. Without this comparison, the data could equally represent a continuous downward trend (preoperative → 1 month → 4–6 months) with only a deceleration in decline. 3. The authors repeatedly cite Solari et al. (2024) and Maloof et al. (2023) to establish a reference trajectory: 6.2 m/s at 1 week → 7.5 m/s at 6 months → 7.7–7.8 m/s at 12 months. However, it is unclear whether these two studies are from the same center, using the same equipment and operator, or whether they represent independent validation cohorts. Presenting findings from one or two studies as a "reference baseline" for clinical decision-making overstates the evidence. Please clarify the provenance of this trajectory and discuss its generalizability. 4. In the Conclusion section, the authors recommend that "when SWV falls below 7.0 m/s at 3 months or 7.5 m/s at 6 months, the rehabilitation protocol should be adjusted." However, in Section 3.4.2, they explicitly acknowledge that these thresholds have not been validated in prospective studies. Placing unvalidated numerical cutoffs in the conclusion risks premature clinical adoption. These should be rephrased as "preliminary research references" rather than actionable clinical recommendations, and the need for validation should be emphasized. 5. The authors recommend routine ultrasound examinations at 1, 3, and 6 months postoperatively. However, no consideration is given to cost-effectiveness, patient adherence, or the actual rate of rehabilitation protocol change resulting from these examinations. Given that most supporting evidence comes from observational studies, this specific schedule is premature. Please reframe this as a research-based monitoring strategy and highlight the need for future RCTs to evaluate its clinical utility and economic viability. 6. The core premise of the manuscript is that ultrasound can guide rehabilitation decisions. However, the authors do not address whether ultrasound-guided protocols can reduce retear rates without increasing the risk of joint stiffness or delayed recovery—both of which are critical safety endpoints. The discussion should either address this evidence gap or acknowledge that current data are insufficient to evaluate the safety balance. 7. The Discussion currently jumps from "main findings" to "comparison with existing reviews" to "clinical pathway feasibility" to "research gaps" without a clear narrative thread. I recommend reorganizing this section along a more logical pathway, which would strengthen the argument and improve readability. Minor questions: 8. The authors state that "the combination of CSA and EI effectively identified patients with rehabilitation bottlenecks." However, the cited studies (Zhu et al., 2024; Liu et al., 2022) are cross-sectional or short-term observational designs that only demonstrate correlation, not causation. It remains unclear whether muscle atrophy causes functional limitation or vice versa. Please revise the language to reflect associations rather than causal relationships. 9. References 7 and 8 are identical duplicates. Please remove one and also check other references. 10. Although Section 3.2 provides a textual description of the included studies, there is no comprehensive table summarizing key characteristics such as sample size, patient demographics (age/sex), tear type/size, surgical approach, follow-up time points, and ultrasound device/model. Such a table would greatly enhance transparency and allow readers to quickly assess the evidence base. Please add this table. ********** what does this mean?). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy Reviewer #1: No Reviewer #2: No Reviewer #3: No ********** [NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.] To ensure your figures meet our technical requirements, please review our figure guidelines: https://journals.plos.org/plosone/s/figures You may also use PLOS’s free figure tool, NAAS, to help you prepare publication quality figures: https://journals.plos.org/plosone/s/figures#loc-tools-for-figure-preparation. NAAS will assess whether your figures meet our technical requirements by comparing each figure against our figure specifications. 4 Aug 2026 Response to Reviewers Manuscript ID: PONE-D-26-27615 Title: Application of Musculoskeletal Ultrasound in Postoperative Rehabilitation Assessment and Monitoring After Rotator Cuff Repair: A Systematic Review Dear Dr. Liu and Reviewers, We sincerely thank the editor and the reviewers for their insightful comments and constructive suggestions on our manuscript. We have carefully considered all the points raised and have revised the manuscript accordingly. Below, we provide our point-by-point responses to each comment. All changes in the revised manuscript are highlighted in yellow for easy identification. Page numbers refer to the revised manuscript with tracked changes. Responses to Journal Requirements Journal Requirement 1: Please ensure that your manuscript meets PLOS ONE's style requirements. Response: We have carefully reviewed the PLOS ONE style templates and have formatted our manuscript accordingly, including file naming conventions. Journal Requirement 2: Please ensure that you have uploaded your PRISMA flowchart as Figure 1. Response: We have uploaded the PRISMA flowchart as Figure 1, as requested. Journal Requirement 3: Please update your submission to use the PLOS LaTeX template. Response: We have carefully reviewed the PLOS ONE formatting requirements and revised the manuscript accordingly to ensure compliance with the journal’s formatting guidelines. Journal Requirement 4 & 5: The grant information provided in the 'Funding Information' and 'Financial Disclosure' sections do not match. Please remove any funding-related text from the manuscript. Response: We have removed all funding-related text from the manuscript and ensured that the grant information in the submission system matches the financial disclosure. The correct grant numbers have been verified. Journal Requirement 6: Please provide a complete Data Availability Statement in the submission form. Response: We have included a complete Data Availability Statement in the submission form. All data presented in this review are derived from the included studies, which are fully cited in the manuscript and supplementary materials. Journal Requirement 7: PLOS requires an ORCID iD for the corresponding author. Response: The corresponding author's ORCID iD has been validated in Editorial Manager. Journal Requirement 8: Figure 2 contains copyrighted images. Please provide permission or remove. Journal Requirement 9: Please remove your figures from within your manuscript file, leaving only the individual TIFF/EPS image files. Response: We apologize for the misunderstanding. Figure 2 is created entirely by the authors using Adobe Photoshop. All graphical elements and layouts were created by the authors using original drawings and publicly available software-generated elements. Journal Requirement 10: Please include a new copy of Table 1; the current table is difficult to read. Response: We have revised Table 1 and improved its readability. Time points have been standardized (e.g., "8 days" instead of "8d"), and all abbreviations have been clarified in the footnotes. Journal Requirement 11: Please include captions for your Supporting Information files at the end of your manuscript. Response: We have included captions for Supporting Information at the end of the manuscript. Journal Requirement 12: If the reviewer comments include a recommendation to cite specific previously published works, please review and evaluate these publications. Response: We have carefully reviewed all reviewer-suggested publications and have cited those that are relevant to our manuscript. These citations have been integrated into the appropriate sections of the text. We are deeply grateful to Reviewer #1 for the thorough and insightful evaluation of our work. Your meticulous reading and constructive suggestions have been instrumental in improving the clarity and rigor of this manuscript. We particularly appreciate your detailed guidance on the risk-of-bias assessment, sample size verification, and methodological transparency. We have carefully addressed each of your concerns, and we believe the manuscript has been substantially strengthened as a result. Please find our point-by-point responses below. Reviewer #1 Comment 1: The risk-of-bias visual summary does not match the stated methodology. Section 2.5 states explicitly that ROBINS-I was applied to the nine non-randomized cohort studies, yet Figures 3 and 4 present the classic seven-domain Cochrane RoB 1 structure built for randomized trials... The figures need to be regenerated with the correct ROBINS-I domain headings. Response: We thank the reviewer for identifying this critical inconsistency. We have now thoroughly revised our risk-of-bias assessment figures. Action Taken: We have regenerated Figures 3 and 4 using the ROBINS-I tool for the nine cohort studies. The figures now display the seven ROBINS-I domains: (1) confounding, (2) selection of participants, (3) classification of interventions, (4) deviations from intended interventions, (5) missing data, (6) measurement of outcomes, and (7) selection of the reported result. The figure titles have also been updated to indicate that the assessments were performed using ROBINS-I. Location in Revised Manuscript: Figures 3 and 4; Section 3.5. Reviewer #1 Comment 2: The reported total sample size does not reconcile with Table 1. The eleven individual sample sizes listed in the table sum to 665, not the 673 stated in section 3.2. Response: We apologize for this arithmetic error. We have rechecked all sample sizes against the original publications. Action Taken: The correct total is 673 (60+89+45+42+50+39+95+48+82+73+50 = 673). We have confirmed that the text in Section 3.2 matches this calculation. Location in Revised Manuscript: Section 3.2. Reviewer #1 Comment 3: The sample size for He and colleagues' 2021 randomized trial is given twice with two different values. Table 1 lists this study with a sample size of 89, while section 4.4.2 states explicitly that 'He et al. (2021) conducted an RCT (n = 81).' Response: We appreciate the reviewer's careful reading. We have verified the sample size from the original publication. Action Taken: The correct figures are: 89 patients enrolled, with 81 completing follow-up. We have clarified in the text that 89 patients were enrolled, with 81 completing the study. In Section 4.4.2, we now refer to the enrolled sample size (n = 89) for consistency with Table 1. Location in Revised Manuscript: Section 4.4.2. Reviewer #1 Comment 4: References 7 and 8 are duplicates. Both entries read identically... yet they are cited together in the introduction as if they were two independent supporting sources. Response: We apologize for this oversight. Action Taken: We have removed the duplicate reference and replaced it with a new relevant reference (Maloof et al., 2025; Orthop J Sports Med). The Introduction now cites only one source [7] for this reference. Location in Revised Manuscript: References [7] and [8]. Reviewer #1 Comment 5: The citation pairing at references 31 and 32 misattributes authorship. The Discussion presents a claim as belonging to 'Xu et al. (2024)' and supports it with the joint citation [31,32], but reference 32 is a 2022 master's thesis by a different author. Response: We thank the reviewer for pointing out this error. Action Taken: We have removed both the conference paper (Xu et al., 2024) and the master's thesis (Hu, 2022) from the references, as these publication types were excluded from our inclusion criteria. We have replaced these citations with more robust evidence from peer-reviewed studies: a systematic review by Lin et al. (2024) and a prospective cohort study by Yan et al. (2025). The corresponding text in Section 4.3 has been revised accordingly. Location in Revised Manuscript: References [31] and [32]; Section 4.3. Reviewer #1 Comment 6: The sentence... introduces low-intensity pulsed ultrasound, a term that appears nowhere else in the paper, without a citation and without any prior mention of a companion protocol. This sentence either needs a proper citation and integration into the argument, or it should be removed. Response: We agree with the reviewer's assessment. Action Taken: We have removed this sentence from Section 4.4.5. Location in Revised Manuscript: Section 4.4.5. Reviewer #1 Comment 7: No inter-rater agreement statistic, such as Cohen's kappa, is reported for either the title and abstract screening stage, the full-text eligibility stage, or the risk-of-bias judgments themselves. Response: The reviewer raises an important methodological point. We acknowledge that formal inter-rater agreement statistics were not calculated during our screening process. Action Taken: We have added a statement in Section 2.4 describing how disagreements were resolved through discussion and consensus, with a third reviewer consulted when necessary. Additionally, we have acknowledged this limitation in Section 4.5. While we acknowledge that a formal Kappa statistic would have strengthened the reproducibility assessment, we believe our consensus-based approach with documented discussion of disagreements represents a transparent and methodologically sound alternative. Location in Revised Manuscript: Section 2.4; Section 4.5. Reviewer #1 Comment 8: A supplementary table listing, for each of the eleven included studies, the ultrasound system manufacturer, model, country of manufacture, transducer frequency and a validation reference for the technique used would directly address the heterogeneity that section 4.4.3 already acknowledges. Response: We agree that this information is essential for readers to assess the comparability of measurements across studies. Action Taken: We have created Supplementary Table S1, which summarizes the ultrasound system manufacturer, model, transducer frequency, measurement technique, ROI definition, and reported reliability for each of the 11 included studies. Location in Revised Manuscript: Supplementary Table S1; Section 3.3. Reviewer #1 Comment 9: None of the quantitative findings summarized from the eleven studies is accompanied anywhere in the manuscript by a confidence interval. Response: We have addressed this by reviewing the original publications. Action Taken: For findings where the original studies reported confidence intervals, we have included them. For studies that did not report CIs, we have explicitly noted this (e.g., "95% CI not reported"). Specifically, we have added the CI for the AUC of 0.922 (95% CI: 0.848 to 0.967) from Zhu et al. (2024), and noted where CIs were not available. Location in Revised Manuscript: Section 3.3.2; Section 3.4.1; Section 4.1. Reviewer #1 Comment 10: The negative finding reported by Kim and colleagues... cannot be interpreted as evidence of absence: with only 42 participants, that study was underpowered to detect anything below a moderate correlation of roughly 0.42. Response: We agree with the reviewer's interpretation. Action Taken: We have added a discussion in Section 4.1 noting that the null finding from Kim et al. (n = 42) should be interpreted with caution, as the study was underpowered to detect correlations below approximately r = 0.42 (assuming 80% power at α = 0.05, two-sided). Thus, the absence of a significant correlation cannot be taken as evidence of no true association. Location in Revised Manuscript: Section 4.1. Reviewer #1 Comment 11: The header row of Table 1 contains the compressed label 'Tear typesize'... The Limitations section contains a near-duplicate sentence... The parenthetical aside built around a long dash... Decimal and formatting verification... Response: We have carefully revised all language and punctuation issues identified by the reviewer. Action Taken: Table 1 header corrected to "Tear type/size" Duplicate sentence in Section 4.5 removed Long dashes revised into separate sentences Decimal formatting standardized to two decimal places for SWV values (e.g., "6.20 to 6.30 m/s") Range expressions standardized to use "to" consistently (e.g., "15% to 21%") Location in Revised Manuscript: Table 1; Section 4.5; Section 3.3.1. Reviewer #1 Comment 12: The introduction... opens with the unreferenced assertion that 'rotator cuff tear is one of the most common musculoskeletal disorders.'... [The authors should cite Oliva et al., I.S.Mu.L.T. Guidelines, Padulo et al., etc.] Response: We thank the reviewer for these valuable suggestions. Action Taken: We have incorporated the recommended references: Oliva et al. (2014) to support the epidemiology statement I.S.Mu.L.T. Rotator Cuff Tears Guidelines (2016) to support arthroscopic repair as mainstream treatment Padulo (2025) in Discussion 4.3 for interdisciplinary approaches Santoboni et al. (2023) in Discussion 4.3 as a methodological parallel Location in Revised Manuscript: References [41]-[44]; Section 1; Section 4.3. Reviewer #1 Comment 13: The PROSPERO registration number given (CRD420261418165) contains fifteen characters, one more than the fourteen-character format... The authors should re-verify this number. Response: We have verified the PROSPERO registration number. Action Taken: The registration number CRD420261418165 is correct and matches our PROSPERO registration record. The 15-character format is valid for PROSPERO IDs. Location in Revised Manuscript: Section 2.1. We sincerely thank Reviewer #2 for the thoughtful and constructive feedback on our manuscript. Your critical assessment of the alignment between our research question and the available evidence was especially valuable. We have carefully reconsidered our language throughout the manuscript, shifting from "guide" to "inform" and "associate with" to more accurately reflect the nature of the evidence. We have also incorporated your suggestions on the AI/large language model perspective and clarified the methodological limitations you raised. We are confident that these revisions have significantly improved the manuscript. Please find our detailed responses below. Reviewer #2 Comment 1: The stated aim is to determine 'which ultrasound parameters ... have been used to guide adjustments of rehabilitation protocols.' Yet the 11 included papers predominantly report statistical associations between MSUS parameters and functional scores... The conclusion that MSUS 'can guide the initiation of active movement...' is therefore not supported by the included evidence. Response: The reviewer raises a critical point. We acknowledge that the evidence base consists primarily of observational studies reporting associations, not interventional studies where ultrasound findings directly triggered protocol changes. Action Taken: We have systematically revised the language throughout the manuscript to accurately reflect the nature of the evidence. Specifically, we have replaced terms such as "guide" and "guided" with more appropriate terms such as "associate with," "inform," and "provide a reference for." The title, abstract, main text, and conclusion have all been revised accordingly. We have also emphasized in the Discussion that most current studies follow an "observation-correlation" model rather than a "measurement-decision" model. We have also carefully removed remaining causal wording and emphasized that current evidence supports association and decision support rather than direct ultrasound-triggered rehabilitation protocols. Location in Revised Manuscript: Abstract; Section 1.4; Section 3.4; Section 4.1; Section 4.3; Section 5. Reviewer #2 Comment 2: Zhao XQ et al. 2025 appears identically as references [7] and [8]. Response: We apologize for this error. As detailed in our response to Reviewer #1 Comment 4, we have removed the duplicate reference and replaced it with a new relevant citation (Maloof et al., 2025). Location in Revised Manuscript: References [7] and [8]. Reviewer #2 Comment 3: The master's thesis (Xie Y, ref [40]) and conference paper (Xu M, ref [31]) are excluded from the synthesis yet are cited in the discussion as supportive evidence. Response: We agree with the reviewer that this was inconsistent. Action Taken: As detailed in our response to Reviewer #1 C Submitted filename: Reviewers.docx 19 Aug 2026 Application of Musculoskeletal Ultrasound in Postoperative Rehabilitation Assessment and Monitoring After Rotator Cuff Repair: A Systematic Review PONE-D-26-27615R1 Dear Dr. Shi, We’re pleased to inform you that your manuscript has been judged scientifically suitable for publication and will be formally accepted for publication once it meets all outstanding technical requirements. Within one week, you’ll receive an e-mail detailing the required amendments. When these have been addressed, you’ll receive a formal acceptance letter and your manuscript will be scheduled for publication. An invoice will be generated when your article is formally accepted. Please note, if your institution has a publishing partnership with PLOS and your article meets the relevant criteria, all or part of your publication costs will be covered. Please make sure your user information is up-to-date by logging into Editorial Manager at Editorial Manager® and clicking the ‘Update My Information' link at the top of the page. For questions related to billing, please contact billing support. If your institution or institutions have a press office, please notify them about your upcoming paper to help maximize its impact. If they’ll be preparing press materials, please inform our press team as soon as possible -- no later than 48 hours after receiving the formal acceptance. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org. Kind regards, Wencai Liu Academic Editor PLOS One Reviewers' comments: Reviewer's Responses to Questions Comments to the Author Reviewer #1: All comments have been addressed Reviewer #2: All comments have been addressed Reviewer #3: All comments have been addressed ********** 2. Is the manuscript technically sound, and do the data support the conclusions??> Reviewer #1: Yes Reviewer #2: Yes Reviewer #3: Yes ********** 3. Has the statistical analysis been performed appropriately and rigorously? -->?> Reviewer #1: Yes Reviewer #2: N/A Reviewer #3: Yes ********** 4. Have the authors made all data underlying the findings in their manuscript fully available??> The PLOS Data policy Reviewer #1: Yes Reviewer #2: Yes Reviewer #3: Yes ********** 5. Is the manuscript presented in an intelligible fashion and written in standard English??> Reviewer #1: Yes Reviewer #2: Yes Reviewer #3: Yes ********** Reviewer #1: well done i have no further suggestions the paper looks emproved after accurate revision qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq Reviewer #2: I appreciate the authors' diligent efforts in revising the manuscript (PONE-D-26-27615R1) and addressing many of the methodological and linguistic concerns raised in the previous round. Reviewer #3: Congratulations. the authors addressed all of my questions. This revised manuscript now features clearlogic and high readability for readers. ********** what does this mean?). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy Reviewer #1: No Reviewer #2: No Reviewer #3: No ********** PONE-D-26-27615R1 PLOS One Dear Dr. Shi, I'm pleased to inform you that your manuscript has been deemed suitable for publication in PLOS One. Congratulations! Your manuscript is now being handed over to our production team. At this stage, our production department will prepare your paper for publication. This includes ensuring the following: * All references, tables, and figures are properly cited * All relevant supporting information is included in the manuscript submission, * There are no issues that prevent the paper from being properly typeset You will receive further instructions from the production team, including instructions on how to review your proof when it is ready. Please keep in mind that we are working through a large volume of accepted articles, so please give us a few days to review your paper and let you know the next and final steps. Lastly, if your institution or institutions have a press office, please let them know about your upcoming paper now to help maximize its impact. If they'll be preparing press materials, please inform our press team within the next 48 hours. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org. You will receive an invoice from PLOS for your publication fee after your manuscript has reached the completed accept phase. If you receive an email requesting payment before acceptance or for any other service, this may be a phishing scheme. Learn how to identify phishing emails and protect your accounts at https://explore.plos.org/phishing. If we can help with anything else, please email us at customercare@plos.org. Thank you for submitting your work to PLOS One and supporting open access. Kind regards, PLOS One Editorial Office Staff on behalf of Dr. Wencai Liu Academic Editor PLOS One