Correction to: Deep learning-based motion correction: cardiac motion artifact and image quality improvements on chest CT Authors: Yoshiyuki Ozawa, Daisuke Takenaka, Masahiko Nomura, Takahiro Ueda, Hirona Kimata, Yuya Ito, Kenji Fujii, Naruomi Akino, Takeshi Yoshikawa, Masahiro Endo, Yoshiharu Ohno Published: 2026 Correction to : Japanese Journal of Radiology https://doi.org/10.1007/s11604-026-01986-8 In Table 3 of the original publication the entry “CPES” and its corresponding values were inadvertently omitted. Table 3Comparisons of quantitative image quality indices between CT data with and without CLEAR MotionCT with CLEAR MotionCT without CLEAR Motionp value CT value Whole lung (mean ± SD) -882.1 ± 68.6-885.4 ± 35.40.87 Right lung (mean ± SD) -887.1 ± 38.9-887.3 ± 39.00.79 Left lung (mean ± SD) -881.2 ± 89.1-883.6 ± 31.40.87 Image noise Whole lung (mean ± SD) 43.0 ± 17.534.9 ± 18.7< 0.0001 Right lung (mean ± SD) 40.9 ± 14.533.5 ± 15.7< 0.0001 Left lung (mean ± SD) 45.1 ± 19.836.4 ± 21.2< 0.0001 SNR Whole lung (mean ± SD) 41.5 ± 6.264.6 ± 7.2< 0.0001 Right lung (mean ± SD) 41.8 ± 5.864.8 ± 7.4< 0.0001 Left lung (mean ± SD) 41.3 ± 6.764.4 ± 7.1< 0.0001 CPED Whole lung (mean ± SD) 2.0 ± 1.62.8 ± 2.70.001 Right lung (mean ± SD) 2.1 ± 1.52.0 ± 1.40.63 Left lung (mean ± SD) 2.0 ± 1.63.6 ± 3.40.0001SNR: signal-to-noise ratio, CPED: cardio-pulmonary edge distance, CPES: cardio-pulmonary edge slope, SD: standard deviation Comparisons of quantitative image quality indices between CT data with and without CLEAR Motion SNR: signal-to-noise ratio, CPED: cardio-pulmonary edge distance, CPES: cardio-pulmonary edge slope, SD: standard deviation The incorrect and the corrected versions of Table 3 are given below. Table 3Comparisons of quantitative image quality indices between CT data with and without CLEAR MotionCT with CLEAR MotionCT without CLEAR Motionp valueCT valueWhole lung(mean ± SD)-882.1 ± 68.6-885.4 ± 35.40.87Right lung(mean ± SD)-887.1 ± 38.9-887.3 ± 39.00.79Left lung(mean ± SD)-881.2 ± 89.1-883.6 ± 31.40.87Image noiseWhole lung(mean ± SD)43.0 ± 17.534.9 ± 18.7< 0.001Right lung(mean ± SD)40.9 ± 14.533.5 ± 15.7< 0.001Left lung(mean ± SD)45.1 ± 19.836.4 ± 21.2< 0.001SNRWhole lung(mean ± SD)41.5 ± 6.264.6 ± 7.2< 0.001Right lung(mean ± SD)41.8 ± 5.864.8 ± 7.4< 0.001Left lung(mean ± SD)41.3 ± 6.764.4 ± 7.1< 0.001CPEDWhole lung(mean ± SD)2.0 ± 1.62.8 ± 2.70.001Right lung(mean ± SD)2.1 ± 1.52.0 ± 1.40.63Left lung(mean ± SD)2.0 ± 1.63.6 ± 3.4< 0.001CPESWhole lung(mean ± SD)486.3 ± 233.3430.1 ± 252.10.001Right lung(mean ± SD)467.8 ± 213.3497.2 ± 238.00.80Left lung(mean ± SD)504.9 ± 252.3361.7 ± 249.7< 0.001SNR: signal-to-noise ratio, CPED: cardio-pulmonary edge distance, CPES: cardio-pulmonary edge slope, SD: standard deviation. Comparisons of quantitative image quality indices between CT data with and without CLEAR Motion SNR: signal-to-noise ratio, CPED: cardio-pulmonary edge distance, CPES: cardio-pulmonary edge slope, SD: standard deviation. Incorrect version: Corrected version: Footnotes Publisher’s note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.