Correction: Indoor methane consistently above outdoor levels in homes with natural gas service Authors: Nathan G. Phillips, Robert Ackley, Andee Krasner Published: 2026 There is an error in affiliation 3 for author Andee Krasner. The correct affiliation 3 is: Independent Public Health Consultant, Boston, Massachusetts, United States of America. In Table 1, all values in Column 6 entitled “Standard Error” are miscalculated. Please see the correct Table 1 here. In S1 Appendix, most values in Column 8 of Table 4, entitled "“Third Floor Minus Outdoor Gas,” are incorrect. It can be viewed below. 10.1371/journal.pone.0357112.t001Table 1Summary statistics of [CH4] concentrations in parts per million (ppm) outdoors and indoors. Indoor concentrations are unadjusted for outdoor concentrations. P-values are for differences between indoor and outdoor [CH4].CategoryOutdoor/Indoor FloorMean(ppm)Standard DeviationNumber of homes (n)Standard ErrorMedian (ppm)P-valueGasOutdoors2.040.101750.012.02No Gas2.030.09200.022.01GasBasement3.953.801640.302.83< 0.0001No Gas2.060.27180.062.02>0.10GasFirst Floor3.352.31166*0.182.63< 0.0001No Gas2.130.25200.062.070.04Gas2nd Floor3.332.181410.182.65< 0.0001No Gas2.110.16120.052.08>.10Gas3rd floor3.322.77410.432.500.005No Gas2.100.2140.102.03***Note that the first floor of a dwelling unit may not be the first floor of a building, for example in multi-story apartments.**P-value is not presented due to the small number of homes with 3rd floors in the no gas group. Summary statistics of [CH4] concentrations in parts per million (ppm) outdoors and indoors. Indoor concentrations are unadjusted for outdoor concentrations. P-values are for differences between indoor and outdoor [CH4]. *Note that the first floor of a dwelling unit may not be the first floor of a building, for example in multi-story apartments. **P-value is not presented due to the small number of homes with 3rd floors in the no gas group. Supporting information Instrument calibration check. We tested the analyzer prior to the beginning of the survey, on February 29, 2024; during a midpoint of the survey, on April 23, 2024, and near the conclusion of the survey on June 19, 2024, against nominal 0.0 ppm; 2.0 ppm and 10 ppm test gasses in ultrapure air. The test gas tanks (Scott-Marrin, Riverside, CA USA) were certified to contain < 0.01 ppm; 2.072 ppm; and 10.32 ppm [CH4] respectively (+/- 1% NIST). Test gasses were supplied to the analyzer using Tedlar bags filled with test gasses and connected to the analyzer inlet during normal operation. Tedlar bags of test gas supply were maintained until the graphical data display indicated the analyzer [CH4] reading stabilized near the nominal value. Table 3 shows the match between analyzer values of [CH4] and test gas values. These results demonstrate that our analyzer was working properly and with adequate precision for the study. (DOCX)