The association between objective visual quality, retinal structure, and dynamic visual acuity Authors: Ruoyu Li, Zesong Wang, Yuexin Wang Published: 2026 ABSTRACT AbstractBackgroundThe dynamic visual acuity (DVA) is crucial to assess dynamic visual function in clinical ophthalmology. The impact of objective ocular parameters on DVA remained unknown, which limits the clinical applicability and interpretability of the DVA test. Thus, the present research aims to investigate the impact of objective visual quality and retinal structure on DVA.MethodsHealthy young myopic adults aged 18 to 35 years were recruited. Binocular dynamic visual acuity (DVA) was evaluated at a 1-meter distance with habitual spectacles. The test comprised four sequential assessments of horizontal motion DVA at increasing velocities of 20, 40, 60, and 80 degrees per second (dps). Modulation transfer function (MTF) and higher-order aberrations (HOA) were measured to evaluate visual quality. Retinal structure, including retinal thickness and capillary density in the optic disc and macula was measured with optical coherence tomography angiography (OCTA).ResultsThirty participants were enrolled with a mean age of 23.0 ± 3.7 years. DVA differed significantly across velocities (P < 0.001). DVA at 20 dps (r = -0.537, P = 0.002) and 60 dps (r = -0.430, P = 0.018) were negatively correlated with the binocular mean sphere. DVA at 20 and 60 dps was significantly associated with MTF value from 5 to 30 cycle/degree (c/d), and 80 dps DVA was associated with MTF value at spatial frequencies from 10 to 20 c/d (P < 0.05, respectively). The Z9 aberration showed a positive association with DVA at 20 dps (P = 0.047), and the Z7 aberration showed a significant positive association with DVA at 80 dps (P = 0.030). Limited associations were observed between DVA and retinal thickness or capillary density in the optic disc and macula.ConclusionsIn healthy myopic adults, better objective visual quality, as measured by MTF, might be associated with better DVA at both low and high speeds, whereas retinal structural parameters had a limited association with DVA. The conclusions are limited by applicating habitual spectacle during the DVA test, which precludes full quantification of optical confounding.Supplementary InformationThe online version contains supplementary material available at 10.1186/s12886-026-04985-5.Keywords: Dynamic visual acuity (DVA), Optical coherence tomography angiography (OCTA), Modulation transfer function (MTF), Higher-order aberration (HOA) Background Dynamic visual acuity (DVA) refers to the capacity to discern subtle spatial details within a visual target during relative motion between the observer and the target [1]. Our daily activities frequently require the perception and interaction with moving objects, and dynamic visual functions significantly affect performance in various tasks, such as reading, sports, driving, and walking [2–4]. There are various DVA tests, including the dynamic-object DVA test, where participants identify or assess moving targets with their head stabilized, and the static-object DVA test, where participants view stationary targets while their head or body is in motion [1, 5, 6]. The dynamic-object DVA (abbreviated as DVA in the following text) test has been applied to assess dynamic visual function in clinical ophthalmology, including cataract, dry eye, myopia and refractive surgery [7–10]. The visual signal transduction pathway of dynamic vision is different from static vision [11]. The difference in the transduction pathway determines different influential factors between dynamic and static vision, including ocular functional and structural parameters. Investigating the impact of objective ocular parameters on DVA could enhance its clinical applicability and improve the interpretability of test results. Previous research demonstrated that myopia severity affects DVA when corrected to normal static vision with spectacles [9]. In addition to refractive error, objective visual quality, including higher-order aberration (HOA) and modulation transfer function (MTF), was also quantified to evaluate static visual quality [12–14]. However, the impact of HOA and MTF on DVA has not been investigated. The retina, with its complex multi-layer, is the key structure for visual signal transduction. Apart from the P ganglion cell, the M ganglion cell-related pathway is critical in transmitting visual signals with high temporal and low spatial frequency, which is related to dynamic vision [15]. Thus, the retinal structural parameters, including retinal thickness and vascularity, could potentially impact DVA, which remains to be fully explored. Thus, the present study included healthy young adults to test DVA at different velocities and assessed total eye MTF and HOA as objective measures of visual quality with an aberrometer, as well as measured macular and optic disc retinal thickness and capillary density using optical coherence tomography angiography (OCTA). OCTA are widely used optical imaging modalities that allow in vivo structural and functional assessment of the neural retina [16]. This study aimed to investigate the influence of objective visual quality and retinal structural parameters on DVA across different velocities. The findings indicate potential factors affecting DVA and provide a foundation for utilizing DVA testing as a tool for assessing visual function. Methods Participants This is a cross-sectional study. Healthy young adults aged 18 to 35 years were recruited for the study, with the following exclusion criteria: (1) monocular best-corrected visual acuity worse than 0 LogMAR (20/20) (subjective refraction); (2) monocular corrected distance visual acuity worse than 0.4 LogMAR (20/50) (habitual spectacles); (3) high myopia (subjective refraction ≤ -6.00D, indicating severe nearsightedness), high hyperopia (subjective refraction ≥ 4.00D, indicating severe farsightedness) or high astigmatism (subjective refraction ≤ -3.00D, indicating severe astigmatism), considering the potential optical artifacts caused by severe refractive error [9]; (3) history of severe ocular diseases, including glaucoma, corneal diseases, retinal disorders, or macular degeneration; (4) Systemic conditions that could potentially affect visual acuity; (5) vestibular or cognitive impairments that may interfere with the accuracy of the test; (6) inability to properly track dynamic visual stimuli or follow instructions provided by the examiner. The study was conducted in accordance with the Declaration of Helsinki, received approval from the Institutional Review Board (No.S2024779), and all participants provided written informed consent before the study. Ocular assessment The ocular assessment was performed in the following order: corrected distance visual acuity assessed with habitual spectacles (LogMAR visual chart), automatic refraction (Topcon, KR-800, Japan), subjective refraction, slit lamp biomicroscopy, OCTA (Cirrus, Zeiss, Germany) and iTrace analyzer (Tracey Technologies, United States). Subjective refraction was performed monocularly with the following steps: first maximum plus to maximum visual acuity (MPMVA) was achieved after fogging, followed by refinement of the cylinder axis and power with the Jackson-cross cylinder device, and a second MPMVA to tune the spherical diopter. A SD-OCTA device with a wavelength of 840 nm and 100,000 A-scans/second was utilized to quantify retinal thickness and capillary density automatically, with a 3 mm × 3 mm scan performed for the macula and a 4.5 mm × 4.5 mm scan for the optic disc. Only images with a signal strength index greater than 8/10 were included. Images with significant motion artifacts, segmentation errors, or poor clarity were excluded. For the retinal thickness, the peripapillary retinal nerve fiber layer (RNFL), fovea (1.0 mm × 1.0 mm), parafovea (1.0 mm to 3.0 mm) thickness, ganglion cell layer thickness (3.0 mm × 3.0 mm) and macular avascular zone size were quantified. For the vascularity, the inside disc (1.5 mm × 1.5 mm) and peripapillary capillary density, superficial and deep fovea (1.0 mm × 1.0 mm) and parafovea (1.0 mm to 3.0 mm) capillary density were quantified. The iTrace analyzer was applied to measure ocular aberration and the MTF curve. The device combines the Placido corneal topography and ray-tracing aberrometry to precisely quantify ocular aberrations. The total eye higher-order aberration at a pupil size of 4.00 mm was recorded and presented in Zernike polynomial coefficients, including Z6 (), Z7 (), Z8 (), Z9 () and Z12 (). The total eye MTF value at a pupil size of 4.00 mm was collected for the analysis, including the spatial frequency of 5, 10, 15, 20, 25 and 30 cycles per degree (c/d). Dynamic visual acuity test Four DVA tests were performed sequentially, with horizontal motion velocities set at 20, 40, 60, and 80 degrees per second (dps). The velocities were selected according to our previous research, considering the variety of eye movement strategies [9]. DVA was examined binocularly with habitual spectacles at 1 m. Habitual spectacles were defined as the participant’s daily-wear corrective glasses. The test optotypes were presented on a 24-inch 120 Hz in-plane switching screen. Custom software, created with MATLAB 2017b (MathWorks, United States), was employed to generate a moving optotype letter E at predefined speeds and sizes. The configuration and size of the optotype letter E were designed based on the standard logarithmic visual chart, and the moving velocity was quantified as the viewing angle changed per second. During the test, the letter E moved across the screen, starting from the midpoint of the left edge and proceeding to the right. Participants were required to identify the opening direction of the letter E in a four alternative forced choice regime. The DVA test began with the optotype size, three steps larger than the subjects’ static visual acuity. Following a preliminary round of five randomly selected optotypes for familiarization, the formal testing phase commenced. During the formal test, eight optotypes of the same size were presented individually at two-second intervals, featuring a randomly oriented opening. If the participant correctly identified at least five out of eight optotypes, the size was decremented by one logMAR step. The smallest optotype size (A, presented in logMAR, range from 0 to 1) at which participants could reliably identify greater than 5/8 optotypes and the count (b, range from 0 to 8) of correctly identified optotypes at the next smaller size were documented. The DVA was computed using the following formula [8]: Lower values indicate better DVA. Statistical analysis Statistical analysis was performed with IBM SPSS Statistics (version 23.0, IBM Corp., United States). Continuous variables were expressed as mean and standard deviation (SD), and categorical variables were expressed as numbers and percentages. The Shapiro-Wilk test was performed to determine the normality of the distribution. A linear mixed model with a random intercept for the participant was applied to compare the DVA of different velocities, followed by a Bonferroni-corrected post-hoc pairwise comparison. Pearson correlation analysis was performed to examine the associations between binocular DVA at various velocities and mean refraction results for normally distributed data. Otherwise, Spearman’s correlation was performed. Generalized linear models with an identity link function and normal distribution were applied to analyze the impact of binocular mean MTF value, higher-order aberration, retinal thickness, and capillary density on DVA at various velocities, adjusting for mean sphere and visual acuity as covariates to control for potential confounding. Because DVA was measured binocularly, optical and structural parameters were averaged across both eyes for primary analyses. Effect sizes are reported as regression coefficients with 95% confidence intervals (CI). Exploratory subgroup analysis was further conducted by individual eye with the same generalized linear model specification. However, these should be interpreted cautiously because measurements from the two eyes of the same participant are correlated. No correction was applied for multiple tests to the generalized linear model. P < 0.05 was determined to be significant. Results Baseline characters A total of 30 participants were enrolled, with a mean age of 23.0 ± 3.7 years, and 40.0% of participants were male. The descriptive results for refraction, MTF value, aberration, retinal thickness and capillary density are summarized in Table 1. The mean sphere power was − 4.52 ± 2.23 diopters (D), and the average cylinder power was − 1.01 ± 0.59 D. The mean corrected distance visual acuity with habitual spectacles was 0.03 ± 0.11 (LogMAR). A significant difference was observed among DVA results at different velocities (P < 0.001). DVA at 20 dps was significantly better than at 40 dps (P < 0.001), 60 dps (P < 0.001), and 80 dps (P < 0.001). Table 1The descriptive results* (n = 30)Age, yearsMeanSDMaxMin23.03.73320Refraction and visual acuitySphere (diopter)-4.522.23-0.38-8.25Cylinder (diopter)-1.010.59-0.13-2.38Spherical equivalent (diopter)-5.022.30-0.50-8.69Corrected distance visual acuity (LogMAR)0.030.110.35-0.13DVA (20 dps, LogMAR)0.14000.10130.01250.3000DVA (40 dps, LogMAR)0.26040.09490.07500.5625DVA (60 dps, LogMAR)0.31040.08360.16250.4500DVA (80 dps, LogMAR)0.29750.10800.07500.5500Total eye modulation transfer function value (4.0 mm)5 c/d (%)0.7480.1140.9210.53010 c/d (%)0.4760.1590.7920.20015 c/d (%)0.3080.1430.6520.09420 c/d (%)0.2200.1090.5240.08625 c/d (%)0.1670.0850.4170.06330 c/d (%)0.1350.0690.3340.052Total eye higher-order aberration (4.0 mm)Z6 (µm)0.0720.0570.2370.006Z7 (µm)0.0820.0480.1830.016Z8 (µm)0.0530.0240.1160.017Z9 (µm)0.0640.0450.2500.005Z12 (µm)0.0470.0300.1230.005Optic disc and macula thickness and capillary densityPeripapillary RNFL thickness (µm)11912146101Fovea thickness (µm)25022306209Parafovea thickness (µm)32311344304Avascular zone (mm2)0.2910.1090.5590.090Inside optic disc capillary density (%)54.33.961.546.1Peripapillary capillary density (%)52.23.060.145.6Superficial fovea capillary density (%)19.66.232.84.9Superficial parafovea capillary density (%)49.73.256.943.9Deep fovea capillary density (%)35.26.948.718.1Deep parafovea capillary density (%)52.53.761.045.1*Binocular mean value is presented for refraction, modulation transfer function value, higher-order aberration and optic disc and macula thickness and capillary densityAbbreviation: dps, degrees per second; DVA, dynamic visual acuity; RNFL, retinal nerve fiber layer; SD, standard deviation The descriptive results* (n = 30) *Binocular mean value is presented for refraction, modulation transfer function value, higher-order aberration and optic disc and macula thickness and capillary density Abbreviation: dps, degrees per second; DVA, dynamic visual acuity; RNFL, retinal nerve fiber layer; SD, standard deviation The correlation between refraction and DVA The outcome of the correlation analysis between mean refraction and DVA is demonstrated in Table 2. DVA at 20 dps (r = -0.537, P = 0.002) and 60 dps (r = -0.430, P = 0.018) were significantly negatively correlated with the mean sphere. DVA at 80 dps was positively correlated with mean visual acuity (r = 0.469, P = 0.009). The results of subgroup analysis by eye are summarized in Table S1. The DVA at 20 dps (P = 0.003), 40 dps (P = 0.036), 60 dps (P = 0.023) and 80 dps (P = 0.046) were negatively associated with the right eye sphere, but a significant correlation between the left eye sphere and DVA was observed only at 20 dps (P = 0.001) and 60 dps (P = 0.018). A significant correlation was observed between DVA at 80 dps and visual acuity in the right eye (P = 0.025) but not in the left (P = 0.059). Table 2The correlation between the refraction result and DVAMean sphereMean SEMean visual acuityDVA (20 dps)r-0.537-0.5980.068P 0.002 < 0.001 0.719DVA (40 dps)r-0.337-0.3500.259P0.0690.0580.167DVA (60 dps)r-0.430-0.4030.309P 0.018 0.027 0.096DVA (80 dps)r-0.335-0.3130.469P0.0700.092 0.009 Abbreviation: dps, degrees per second; DVA, dynamic visual acuity; SE, spherical equivalent The correlation between the refraction result and DVA Abbreviation: dps, degrees per second; DVA, dynamic visual acuity; SE, spherical equivalent The impact of objective visual quality on DVA The impact of the total eye MTF value of different spatial frequencies on DVA is demonstrated in Table 3. Higher MTF values at the spatial frequencies of 5 to 30 c/d were significantly associated with better DVA at 20 dps, with regression coefficients (β) ranging from − 0.338 (5 c/d, P = 0.013) to -0.511 (30 c/d, P = 0.021). Similarly, at 60 dps, significant negative associations were found at higher spatial frequencies (15 to 30 c/d), with β values ranging from − 0.239 (15 c/d, P = 0.009) to -0.488 (30 c/d, P = 0.010). For DVA at 80 dps, significant negative associations were observed at spatial frequencies from 10 to 20 c/d, with β values ranging from − 0.250 (10 c/d, P = 0.021) to -0.312 (20 c/d, P = 0.050). No significant associations were observed between MTF values at all spatial frequencies and DVA at 40 dps (P > 0.05, respectively). The results of the subgroup analysis by eye are summarized in Table S2. For the right eye, significant negative associations between MTF values and DVA at 60 and 80 dps were observed at spatial frequencies ranging from 10 to 25 c/d (P < 0.05, respectively). In the left eye, a significant negative association was observed between DVA at 20 and 60 dps and MTF values (P < 0.05, respectively). Table 3The impact of the total eye MTF value of different spatial frequencies* on DVA5 c/d10 c/d15 c/d20 c/d25 c/d30 c/dDVA (20 dps)β-0.338-0.253-0.302-0.384-0.457-0.51195% CI-0.606 to -0.070-0.440 to -0.066-0.503 to -0.101-0.649 to -0.119-0.805 to -0.110-0.945 to -0.078P 0.013 0.008 0.003 0.005 0.010 0.021 DVA (40 dps)β-0.027-0.066-0.101-0.112-0.119-0.11695% CI-0.334 to 0.280-0.281 to 0.150-0.336 to 0.135-0.421 to 0.197-0.518 to 0.280-0.605 to 0.374P0.8620.5490.4020.4780.5580.643DVA (60 dps)β-0.140-0.158-0.239-0.340-0.427-0.48895% CI-0.393 to 0.113-0.332 to 0.015-0.420 to -0.059-0.571 to -0.109-0.726 to -0.127-0.861 to -0.115P0.2780.073 0.009 0.004 0.005 0.010 DVA (80 dps)β-0.291-0.250-0.278-0.312-0.352-0.39195% CI-0.608 to 0.059-0.476 to -0.017-0.531 to -0.030-0.702 to -0.021-0.751 to 0.131-0.891 to 0.195P0.065 0.021 0.019 0.037 0.0910.129*The MTF parameter was measured at a pupil size of 4.0 mmAbbreviation: c/d, cycles per degree; CI, confidence interval; dps, degrees per second; DVA, dynamic visual acuity; MTF, modulation transfer function The impact of the total eye MTF value of different spatial frequencies* on DVA *The MTF parameter was measured at a pupil size of 4.0 mm Abbreviation: c/d, cycles per degree; CI, confidence interval; dps, degrees per second; DVA, dynamic visual acuity; MTF, modulation transfer function The impact of total eye higher-order aberration on DVA is presented in Table 4. Specifically, the Z9 aberration showed a significant positive association with DVA at 20 dps (β = 0.685, P = 0.047), and the Z7 aberration showed a significant positive association with DVA at 80 dps (β = 0.799, P = 0.030). No significant associations were detected between other types of higher-order aberration and DVA at 40 and 60 dps (P > 0.05, respectively). The results of subgroup analysis by eye are summarized in Table S3. For the left eye, a significant positive association was found between the Z9 aberration and DVA at 20 dps (β = 0.548, P = 0.027). No significant associations were observed between higher-order aberration in the right eye and DVA across all velocities (P > 0.05, respectively). Table 4The impact of total eye higher-order ocular aberration* on DVAZ6Z7Z8Z9Z12DVA (20 dps)β0.4360.3530.0440.6850.98595% CI-0.102 to 0.974-0.294 to 0.100-1.272 to 1.3610.010 to 1.359-0.006 to 1.976P0.1120.2850.947 0.047 0.052DVA (40 dps)β0.106< 0.001-0.1770.414-0.10595% CI-0.476 to 0.689-0.687 to 0.687-1.546 to 1.192-0.319 to 1.147-1.201 to 0.992P0.7200.9990.8000.2690.851DVA (60 dps)β0.2640.2980.2560.300-0.34095% CI-0.218 to 0.746-0.269 to 0.865-0.893 to 1.405-0.320 to 0.921-1.255 to 0.575P0.2840.3030.6620.3420.466DVA (80 dps)β0.4870.7991.0080.3580.04895% CI-0.152 to 1.1270.076 to 1.523-0.504 to 2.520-0.482 to 1.197-1.197 to 1.293P0.135 0.030 0.1910.4040.940*The total eye higher-order ocular aberration was measured at the pupil size of 4.0 mm and presented in Zernike polynomialAbbreviation: CI, confidence interval; dps, degrees per second; DVA, dynamic visual acuity The impact of total eye higher-order ocular aberration* on DVA *The total eye higher-order ocular aberration was measured at the pupil size of 4.0 mm and presented in Zernike polynomial Abbreviation: CI, confidence interval; dps, degrees per second; DVA, dynamic visual acuity The impact of retinal structure on DVA The impact of the optic disc and macular structure on DVA is demonstrated in Table 5. No significant associations were observed between peripapillary RNFL thickness, foveal thickness, parafoveal thickness, ganglion cell layer thickness, avascular zone area and DVA across all velocities (P > 0.05, respectively). The results of the subgroup analysis by eye are summarized in Table S4. A statistically significant positive association was observed between peripapillary RNFL thickness of the right eye and DVA at 60 dps (β = 0.002, P = 0.013). For the left eye, a significant positive association was found between the avascular zone area and DVA at 80 dps (β = 0.391, P = 0.022). Table 5The impact of optic disc* and macular# structure on DVAPeripapillary RNFL thicknessFovea thicknessParafoveathicknessGanglion Cell layer thicknessAvascularzoneDVA (20 dps)β0.002-0.001-0.001-0.0010.17995% CI0.000 to 0.004-0.002 to 0.000-0.004 to 0.002-0.003 to 0.005-0.108 to 0.466P0.1150.1380.1620.5720.221DVA (40 dps)β< 0.001< 0.001-0.001< 0.0010.11695% CI-0.003 to 0.002-0.002 to 0.001-0.004 to 0.002-0.030 to 0.000-0.186 to 0.419P0.8120.5720.7070.9210.451DVA (60 dps)β0.002-0.001-0.0010.0010.15295% CI0.000 to 0.004-0.002 to 0.001-0.004 to 0.001-0.003 to 0.004-0.100 to 0.404P0.0850.2790.2880.6100.238DVA (80 dps)β0.001-0.001< 0.0010.0010.31995% CI-0.002 to 0.004-0.003 to 0.000-0.004 to 0.003-0.003 to 0.006-0.010 to 0.648P0.4240.1400.8500.6550.057*The optic disc retinal nerve fiber layer thickness was measured at a size of 4.5 mm × 4.5 mm#The fovea thickness was measured at a size of 1.0 mm × 1.0 mm, and the parafovea thickness was measured at a range between 1.0 mm and 3.0 mm, and the ganglion cell layer thickness was measured at a range of 3.0 mmAbbreviation: CI, confidence interval; dps, degrees per second; DVA, dynamic visual acuity; RNFL, retinal nerve fiber layer The impact of optic disc* and macular# structure on DVA *The optic disc retinal nerve fiber layer thickness was measured at a size of 4.5 mm × 4.5 mm #The fovea thickness was measured at a size of 1.0 mm × 1.0 mm, and the parafovea thickness was measured at a range between 1.0 mm and 3.0 mm, and the ganglion cell layer thickness was measured at a range of 3.0 mm Abbreviation: CI, confidence interval; dps, degrees per second; DVA, dynamic visual acuity; RNFL, retinal nerve fiber layer The impact of optic disc and macular capillary density on DVA is presented in Table 6. A significant negative association was observed between peripapillary capillary density and DVA at 80 dps (β = -0.013, P = 0.019). No other significant associations were detected between capillary density in the optic disc (inside disc), superficial macula (fovea and parafovea), or deep macula (fovea and parafovea) and DVA across all velocities (P > 0.05, respectively). The results of the subgroup analysis by eye are summarized in Table S5. For the right eye, significant negative associations were observed between peripapillary capillary density and DVA at 80 dps (β = -0.014, P = 0.007) and between parafoveal deep macular capillary density and DVA at 80 dps (β = -0.007, P = 0.047). A significant negative association was found between the foveal deep macular capillary density of the left eye and DVA at 80 dps (β = -0.005, P = 0.027). Table 6The impact of optic disc* and macular# capillary density on DVAOptic DiscSuperficial maculaDeep maculaInside discPeripapillaryFoveaParafoveaFoveaParafoveaDVA (20dps)β-0.002-0.003-0.0020.002-0.003-0.00495% CI-0.011 to 0.008-0.014 to 0.007-0.007 to 0.003-0.007 to 0.012-0.007 to 0.001-0.013 to 0.005P0.7260.5110.4120.6240.1660.378DVA (40dps)β-0.004-0.004-0.0020.004-0.0020.00295% CI-0.013 to 0.006-0.014 to 0.007-0.007 to 0.004-0.005 to 0.014-0.006 to 0.003-0.008 to 0.011P0.4710.4930.5340.3820.5230.711DVA (60dps)β-0.001-0.006-0.0010.001-0.002-0.00195% CI-0.009 to 0.008-0.015 to 0.003-0.006 to 0.003-0.007 to 0.010-0.006 to 0.002-0.009 to 0.007P0.8880.1740.5390.8000.4280.809DVA (80dps)β0.004-0.013-0.0030.003-0.0040.00295% CI-0.007 to 0.014-0.025 to -0.002-0.009 to 0.002-0.008 to 0.014-0.009 to 0.002-0.008 to 0.013P0.522 0.019 0.2520.5880.1740.654*The inside disc capillary density was measured at a size of 1.5 mm × 1.5 mm, and the peripapillary capillary density was measured at a range between 1.5 mm and 4.5 mm#The fovea capillary density was measured at a size of 1.0 mm × 1.0 mm, and the parafovea capillary density was measured at a range between 1.0 mm and 3.0 mmAbbreviation: CI, confidence interval; dps, degrees per second; DVA, dynamic visual acuity The impact of optic disc* and macular# capillary density on DVA *The inside disc capillary density was measured at a size of 1.5 mm × 1.5 mm, and the peripapillary capillary density was measured at a range between 1.5 mm and 4.5 mm #The fovea capillary density was measured at a size of 1.0 mm × 1.0 mm, and the parafovea capillary density was measured at a range between 1.0 mm and 3.0 mm Abbreviation: CI, confidence interval; dps, degrees per second; DVA, dynamic visual acuity Discussion Dynamic visual acuity (DVA) is crucial for tasks involving moving objects and serves as a promising metric for assessing visual function [17]. However, the factors influencing DVA have not been fully investigated. This study aimed to explore the impact of objective visual quality, including higher-order aberrations and MTF, and retinal structural parameters on DVA across different velocities in healthy young adults. The goal was to identify key influential factors and enhance the clinical utility of the DVA test. Velocity is a significant influential factor for DVA. The present research demonstrated that DVA at 20 dps was significantly better than at higher speeds, and no significant differences were observed between DVA at 40 dps and 80 dps, or between 60 dps and 80 dps. These results are consistent with our previous research on horizontal motion DVA [18]. As velocity increases, the ability to track moving targets diminishes, significantly impacting DVA outcomes [19, 20]. Refractive errors significantly influence DVA, including uncorrected and corrected refractive errors [9, 21]. For uncorrected refractive errors, previous studies have shown that minor retinal defocus may not significantly affect athletic performance. However, higher refractive errors are likely to impair DVA [22]. Additionally, Jorge et al. identified a significant correlation between DVA and astigmatism [17]. In the present research, all participants had their static visual acuity (SVA) corrected with habitual spectacles during the DVA test. The binocular mean sphere and SE had significant correlations with DVA at 20 and 60 dps, while the monocular sphere and SE in the right eye were significantly correlated with DVA at all tested velocities. These results suggest that the further the refractive state deviates from emmetropia, the worse the DVA, even after correction. This finding aligns with our previous research [9]. There are several potential reasons. First, for participants with more severe myopia, the prism effect of the spectacles became more pronounced. The prism effect might cause spatial disorientation, which impairs the ability to track moving targets and leads to worse DVA performance. Second, the defocus effect in the peripheral regions of spectacles reduces visual clarity outside the central visual field, essential for tracking objects moving across a wide range of visual angles [23]. Considering the instinct flaws of spectacles, the application of contact lens or refractive surgery might minimize the spectacle-related artifacts. The subgroup analysis revealed that the right eye’s refractive error had significant correlations with DVA at 40 and 80 dps, while the left eye did not. In our study, the right eye was more frequently the dominant eye among participants. Previous studies have found that, compared to the nondominant eye, the dominant eye is more sensitive and performs better in visual target detection [24]. The visual sensitivity difference between the dominant and nondominant eye might explain the greater influence of the right eye’s refractive error on DVA. The MTF value is a widely recognized metric for evaluating objective visual quality. It quantifies the resolution of an optical system at different spatial frequencies [14]. The present research found negative associations between MTF values and DVA at 20, 60 and 80 dps, suggesting that superior visual quality contributes to better DVA performance. Significant associations between DVA at 20 and 60 dps and MTF values were observed across low to high spatial frequencies. In contrast, DVA at 80 dps was associated with MTF values at spatial frequencies from 10 to 20 c/d but not at high spatial frequencies. The results might be attributed to the difference between static and dynamic visual signal transduction, which becomes more pronounced at higher velocities. The M ganglion cell-related pathway mainly transmits visual signals with low spatial and high temporal frequencies, which is associated with dynamic vision [15]. At 40 dps, no significant association was observed between MTF values and DVA. One possible explanation is perceptual learning or transfer effects from the preceding 20 dps test [18]. Future studies employing randomized or counterbalanced velocity sequences are needed to disentangle the learning effect. The retinal structure, including retinal thickness and vascularity, might influence visual signal transduction. In the present research, higher capillary density in the peripapillary area was associated with better DVA at 80 dps. However, no significant relationship was observed between DVA and macular thickness or vascularity. These findings suggest that increased vascular density in the optic nerve head, rather than in the macular region, may enhance visual perception during rapid motion. Previous studies have demonstrated that M ganglion cells, which are primarily linked to rod cells, are related to the transduction of dynamic visual signals [15]. The mid-peripheral retina, rather than the macular region, contains the highest density of rod cells, which might explain the lack of association between macular structure and DVA. Further research is required to investigate the potential impact of peripheral retinal structure and rod cell density on DVA. In contrast to high-speed DVA, low-speed DVA was not associated with retinal structure in this study. These results indicate that higher-speed DVA might serve as a more promising indicator of subtle retinal structural damage than lower-speed DVA. Consistent across velocities, higher MTF values were associated with better DVA. In contrast, isolated significant associations for specific Zernike terms or single OCTA parameters should be interpreted cautiously, as they may reflect chance findings given the number of comparisons and modest sample size. While the present study identifies statistically significant associations between objective optical quality (MTF) and DVA in healthy young myopic adults wearing habitual spectacles, the translation of these findings into routine clinical practice requires careful consideration. Currently, DVA testing remains primarily a research tool, and normative thresholds for clinical decision-making have not been established. The observed associations suggest that objective metrics like MTF may complement traditional static visual acuity measures in assessing visual function, particularly for activities involving motion perception such as driving or sports. However, given the use of habitual spectacles and the restricted demographic, these findings cannot be directly generalized to clinical populations with different refractive profiles or to those wearing contact lenses or with refractive surgeries. Future research should establish standardized DVA protocols, validate these associations in larger prospective cohorts with diverse refractive statuses, and determine specific clinical scenarios where DVA assessment coupled with optical quality metrics would provide actionable diagnostic or prognostic information beyond current standard examinations. This study has several limitations that constrain the interpretation and generalizability of the findings. First, DVA was evaluated using habitual spectacles. While this approach reflects real-world conditions, it introduces a systemic optical confounder. The habitual prescription may deviate from the subjective refraction. Unfortunately, the exact habitual spectacle prescription was not recorded, precluding quantification of the discrepancy. Although static vision and refractive error were adjusted using the generalized linear model, their influence could not be completely ruled out. The optical limitation precludes isolation of pure retinal or neural factors and restricts generalizability to other populations. Standardized correction (e.g., trial frames or contact lenses) would better isolate these factors in future studies. Second, only horizontally moving DVA was assessed in this study. Other motion patterns, such as vertical and diagonal motion, may be influenced by different factors, which require further investigation. Third, the sample size was not supported by a formal prior power calculation and the study remains underpowered for small effects and vulnerable to model instability, highlighting the need for larger-scale studies in the future to validate these findings. Fourth, potential confounding factors were not considered in the subject inclusion that might influence the visual processing or cognitive function, such as high-performance sports, educational attainment, or reading habits. Fifth, the failure to assess ocular dominance represents a significant limitation, as the observed asymmetry in right and left eyes may suggest that dominant eye performance may differentially drive binocular DVA outcomes, and unrecorded dominance status prevents stratified analysis of this potential confounder. Sixth, the study only assesses retinal thickness in the macular region, which primarily reflects the parvocellular pathway. Dynamic vision predominantly engages the magnocellular pathway and mid-peripheral retina. The absence of peripheral retinal structural assessment and evaluation of rod-cell function limits mechanistic interpretation of the velocity-dependent findings. Seventh, the four DVA tests were conducted sequentially in a fixed order, and the learning or fatigue effect might impact the results. Including randomized velocity orders would reduce these effects in future studies. Eighth, the generalized linear model analysis examines multiple predictors across velocities. The approach may increase the risk of false positives, and the isolated significant association should be interpreted cautiously. Ninth, eye-level subgroup analyses treated right and left eyes as independent units, which should be interpreted cautiously because measurements from the two eyes of the same participant are correlated and standard generalized linear models do not account for this hierarchical dependency. Conclusions The cross-sectional study investigates the relationship between DVA and objective visual quality and retinal structure in healthy young myopic adults. The findings suggest that a higher modulation transfer function (MTF) value was associated with better DVA at both low and high velocities. However, only weak or nonsignificant associations were observed between DVA and retinal thickness or capillary density in the optic disc and macula. The findings indicate that objective optical quality metrics may be relevant to dynamic visual performance. However, these conclusions are restricted to healthy young myopic adults wearing habitual spectacles and clinical translation requires validation in larger, prospectively designed studies with standardized protocols and diverse refractive populations. Supplementary Information Below is the link to the electronic supplementary material. Supplementary Material 1 Abbreviations Cycles per degree Degrees per second Dynamic visual acuity Higher-order aberration First maximum plus to maximum visual acuity Optical coherence tomography angiography Retinal nerve fiber layer Standard deviation Spherical equivalent Author contributions Conceptualization: Y. W.; Methodology: Y. W.; Investigation: Y. W., R. L., Z. W.; Data curation: R. L., Z. W.; Formal analysis: Y. W., R. L.; Writing-original draft preparation: R. L.; Writing-review and editing: Y. W. Funding This research was funded by the National Natural Science Foundation of China, grant number 82201243 and 82571273. Data availability The datasets generated during the current study are available from the corresponding author upon reasonable request. Declarations Ethics approval and consent to participate The study was conducted in accordance with the Declaration of Helsinki and approved by the Ethics Committee of Peking University Third Hospital (No.S2024779). Written informed consent was obtained from each participant before enrollment. Consent for publication Not applicable. Competing interests The authors declare no competing interests. Footnotes Publisher’s note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations. References Associated Data Supplementary Materials Supplementary Material 1 Data Availability Statement The datasets generated during the current study are available from the corresponding author upon reasonable request.