Shoulder-wearable soft robot for assisting older adults in scapular stretching Authors: Kosuke Isobe, Masakazu Hirokawa, Yasuhiro Suzuki, Hideki Kadone, Yukiyo Shimizu, Kenji Suzuki Published: 2026 ABSTRACT We propose a wearable soft robot that assists with individualized scapula adduction and abduction for thoracic stretching in respiratory rehabilitation. Although thoracic stretching is known to be effective for respiratory rehabilitation, the range of motion of older adult patients narrows with age, and long-term external aid by physical therapists is required. The proposed robot consists of a soft and shoulder-wearable brace and cable-pulling mechanism to apply rotational torque on shoulders, resulting in stretching the thorax and scapulae. We designed the pulling mechanism by modeling the humeral head trajectory during stretching by a therapist and reproducing it with two linear actuators pulling the right and left shoulders simultaneously, based on position control aimed at achieving a target tension. The main results of validation experiments with older adults confirmed that the robot-assisted stretching was able to perform scapular stretching similar to that of a physical therapist. Introduction Chronic obstructive pulmonary disease (COPD) was the third leading cause of death worldwide in 2019 (Seattle, WA: Institute for Health Metrics and Evaluation, 2019). COPD is more common in older adults (Halbert et al., 2006). In addition, COPD, caused by irreversible and slowly progressive lung lesions, is a chronic condition (COPD Guideline 6th Edition Development Committee, 2022). It requires patients to undergo long-term treatment and support to prevent the gradual progression of the disease. Among respiratory rehabilitation, exercise therapy is one of the fundamental components of COPD treatment, which aims to improve physical activity by combining respiratory muscle stretching, lower-limb muscle training, and strength training of the upper limb and respiratory muscles. Respiratory muscle stretching is a technique for improving the mobility of respiratory muscles and respiratory accessory muscles, such as the diaphragm and intercostal muscles through upper-limb movements, including scapular movements that are effective for reducing dyspnea (COPD Guideline 6th Edition Development Committee, 2022) and increasing chest expansion (Rehman et al., 2020). The effectiveness of exercise therapy in maintaining physical function, such as a 6-min walking distance and the COPD assessment test, has been verified (Zanaboni et al., 2017). As the active range of motion (ROM) of the shoulder and scapula decreases with aging (Barnes et al., 2001; Endo et al., 2004), older adults may not be able to move their shoulders and scapula through a full ROM with active stretching alone. Consequently, for older adults who cannot achieve a full ROM, externally assisted stretching becomes crucial. Specifically, manual therapy techniques targeting the thoracic region have been shown to provide immediate improvements in respiratory function (e.g., FEV 1.0Subscript 1.0 ) and reduce dyspnea in patients with COPD (Yilmaz Yelvar et al., 2016). Manual therapy by physical therapists is a technique to assist in expanding the ROM by applying external force. In manual therapy, the physical therapists mobilize the shoulder by grasping and moving it, thereby activating shoulder adductor muscles such as the pectoralis major, which secondarily enhances thoracic mobility. While patients themselves can stretch with external force using elastic bands and stretching machines, physical therapists have the advantage of being able to adjust the force, direction, and timing appropriately. Another advantage of manual therapy is that COPD patients often have musculoskeletal disorders, which may benefit from manual intervention (Chen et al., 2017). Thus, physical therapists are essential, and the demand for physical therapists is estimated to increase (Ministry of Health, Labour, and Welfare, 2019). Especially in a super-aging society such as Japan, the burden on physical therapists is significant. Therefore, the ability to consistently provide such high-quality interventions is largely dependent on the experience and skills of physical therapists, and there are also issues such as physical burden, time constraints, and regional maldistribution. Furthermore, there is a need to realize individualized rehabilitation based on more objective and quantitative data and to provide continuous intervention support outside of facilities, such as at home. Therefore, there is a need for robots that can assist or supplement the work of physical therapists. There are several challenges in reproducing thoracic stretching performed by physical therapists using robots. First, it is necessary to control not only the upper arm angle but also the humeral head position. Robotic systems capable of supporting these high degrees of freedom (DoF) are often bulky. Second, physical therapists qualitatively adjust the force application and movement direction for each individual based on the shoulder reaction force perceived in their hands during stretching. By perceiving shoulder reaction forces and the sensation at the final ROM, known as the end-feel (Cyriax, 1978), physical therapists provide optimal stretching tailored to individual patients. Such highly individualized adjustment is also a crucial factor in robotic interventions. However, the perception of end-feel can vary depending on the skill level of the physical therapist (Tasaka et al., 2019). Furthermore, although quantification based on force–displacement characteristics (Maitland and Kawchuk, 1997) has been proposed, this approach has been inadequate for complex joints such as the shoulder. Therefore, in this study, we empirically aim for movement up to the final ROM by using the judgment of the patient, limitations imposed by hardware, and real-time measurement of force–displacement values. In addition, the size of the robot needs to be small enough to be used at home. Therefore, this study aims to reproduce the thoracic stretching intervention of a physical therapist using a wearable robot. This work targets a passive therapeutic intervention – scapular stretching – specifically designed to support respiratory rehabilitation in older adults. Using a low-degree-of-freedom cable-driven system to manage a complex joint presents a highly compact alternative to traditional rigid rehabilitation exoskeletons. Our main contributions are as follows:Proposed a shoulder-wearable soft robot for assisting scapular adduction and abduction stretching that adjusts the intensity according to the individual.Clarified the mechanical properties of the proposed robot.Verified the feasibility based on the scapular movement of younger and older adults. Proposed a shoulder-wearable soft robot for assisting scapular adduction and abduction stretching that adjusts the intensity according to the individual. Proposed a shoulder-wearable soft robot for assisting scapular adduction and abduction stretching that adjusts the intensity according to the individual. Clarified the mechanical properties of the proposed robot. Clarified the mechanical properties of the proposed robot. Verified the feasibility based on the scapular movement of younger and older adults. Verified the feasibility based on the scapular movement of younger and older adults. Related works There are several robotic methods to assist the wider ROM of people’s shoulder joints with different purposes and mechanisms. Several reviews have been published on upper-limb exoskeletons (Gull et al., 2020; Dhatrak et al., 2024). However, few exoskeletons or robots have been designed to assist older adults in respiratory muscle stretching. Passive shoulder movement assistance Stretching machines are used to improve muscle flexibility and strength. The Chest Spread (Park Corp.), a stretching machine, is designed to stretch chest and back muscles (Chest Spread, 2020). It consists of a simple mechanism that does not require the control of human joint angles. With the aid of this machine, the user can perform thoracic stretching without the therapist’s support. However, since this machine was designed to adjust its intensity based on the lower-limb movement (e.g., pedaling), its use is challenging for older adults with limited lower-limb mobility. Passive mechanisms are used in industrial exosuits to assist shoulder motion (Tian et al., 2024). However, many mechanisms use gravity-compensation mechanisms to support long-duration tasks, making it difficult to apply them to stretching scapulae. Robotic movement assistance Upper-limb exoskeletons are used for medical and rehabilitation purposes such as neurorehabilitation, musculoskeletal rehabilitation, and motion assessment. For shoulder or scapular rehabilitation purposes, these exoskeletons provide high DoF control of the shoulder. Gopura et al. (2009) developed a 7-DoF upper-limb exoskeleton robot that can assist shoulder internal/external rotation. The robot is capable of supporting shoulder rotation through a mechanism that adjusts to the shoulder rotation center displacement. In addition, B Kim and Deshpande (2017) developed an exoskeleton system, “Harmony,” that can support glenohumeral joint and upper arm movements. The robot uses a 2-DoF mechanism to control the position of the humeral head to adjust to the displacement of the center of rotation of the shoulder. However, exoskeletons that support shoulder joint movements for bilateral configurations such as “Harmony” are often bulky due to their complex mechanisms to support movements with many DoFs (Rosen et al., 2014; Kim and Deshpande, 2017; Gull et al., 2020; Dhatrak et al., 2024). Several exoskeletons or exosuits for assisting activities of daily living (ADL) for occupational purposes are more compact than exoskeletons for rehabilitating patients with paralysis (Jalal et al., 2024; Tian et al., 2024). For example, Kwok and Yu (2024) developed a lightweight bilateral underactuated upper-limb exoskeleton for bimanual ADL. In addition, Kim et al. (2018) developed a soft exosuit for industrial applications. However, these exoskeletons only provide assistance or gravity compensation for the shoulder abduction/adduction and shoulder extension/flexion and thus cannot achieve scapular adduction/abduction. They achieve compactness by treating humeral head displacement as an acceptable or negligible misalignment. Continuous passive motion (CPM) machine is a mechanical device that supports a joint and can be set to move slowly through a designated ROM to promote controlled movement in the operated joint (Intervention applications, 2013). For example, the Kinex Shoulder CPM machine (Kinex Medical Company, 2018) is designed to move the patient’s shoulder joint through a prescribed ROM over a specified duration. However, most CPM machines do not consider changes in the position of the humeral head. Some robots for respiratory rehabilitation assistance have also been studied (Zhu et al., 2015; Lee et al., 2022; Zhang et al., 2024; Zhou et al., 2025). Zhou et al. (2025) have proposed a bedside assistive robot using pneumatic actuators. This robot is a soft robot and is more comfortable than rigid robots. However, because it uses pneumatics, it requires the use of air compressors and other equipment, making it difficult to use at home. Cable-driven wearable approach Among the robotic assistance approaches, cable-driven wearable robots for the shoulder are suitable for home use due to their lightweight and compact design. Several cable-driven mechanisms are designed to support upper-limb movement, including the displacement of the humeral head (Samper-Escudero et al., 2020; Georgarakis et al., 2022). However, most methods are intended to assist with daily life activities and reduce the burden of work. Therefore, these cable-driven exoskeletons are designed to support the arm-raising motion based on the scapulohumeral rhythm; hence, they are not sufficient to assist the scapular adduction/abduction for thoracic stretching (Thalman and Artemiadis, 2020). Several studies suggested wearable robots for resistance training that consider the movement of the humeral head. Park et al. developed a wearable fitness device for upper-limb exercise that constitutes cable-driven actuation to control the resistance profiles (Park et al., 2023). In addition, Pyeon et al. (2024) developed a cable-driven exosuit for upper-limb home fitness, capable of transmitting bidirectional resistance and applying focused loads to specific muscles utilizing cable routing. However, the primary objective of resistance training is strengthening muscle strength and muscular endurance, not to control the position or increase the ROM of the humeral head. Although many related studies have shown that the shoulder can assist with the ROM required for ADL, few studies have examined the effectiveness of robotic stretching for older adults in comparison with manual therapy. We focus on a wearable robot with a cable-driven system to achieve stretching at home. A model is needed for movements involving scapular adduction/abduction. There is a musculoskeletal model for the scapula and shoulder, but it is difficult to simplify as much as the scapulohumeral rhythm, and the high DoF make the robot bulky. Therefore, the design is aimed only at supporting the movement of thoracic stretching. A cable-driven robot for thoracic stretching has also been proposed by our group (Isobe et al., 2023). This device was designed to support the adduction and abduction of scapulae by controlling the position of the humeral head using a 2-DoFs cable-driven mechanism. However, in the study, due to safety concerns and to align the intervention conditions, the same control parameters (e.g., pulling force) were applied to all participants regardless of their physical size and/or strength. As a result, the robotic stretching was unable to provide sufficient support regarding the ROM compared to the manual stretching by a therapist. Therefore, the pulling force needs to be adjusted to the individual to ensure that the robot provides a sufficient ROM. However, that study was limited to younger participants, leaving its effectiveness for older adults unverified. Therefore, verification is also needed for older adults. To address these limitations and ensure clinical applicability, the current study incorporates the following specific advancements compared to our previous work (Isobe et al., 2023):an individualized target tension procedure based on user feedback;a modified spine fixation mechanism to support the C7 reference point;a mechanical characterization of Bowden cable friction effects; anda feasibility study with older adults and comparison to a physical therapist. an individualized target tension procedure based on user feedback; an individualized target tension procedure based on user feedback; a modified spine fixation mechanism to support the C7 reference point; a modified spine fixation mechanism to support the C7 reference point; a mechanical characterization of Bowden cable friction effects; and a mechanical characterization of Bowden cable friction effects; and a feasibility study with older adults and comparison to a physical therapist. a feasibility study with older adults and comparison to a physical therapist. Summary of the related works Robots such as the upper-limb exoskeletons and exosuits in the previous studies mentioned above have not been investigated for the purpose of assisting thoracic stretching. To achieve thoracic stretching, controlling the humeral head position based on the understanding of the scapular motion is crucial. However, due to the high degree of freedom of the scapular movement, conventional exoskeleton approaches require a large mechanism. To make the system suitable for home use, it is essential to create a simpler mechanism. Exoskeletons and wearable robots designed for thoracic stretching lack performance verification of their effect on actual users’ range of movement, particularly for older adults. Therefore, in this study, we propose a shoulder-wearable robot with a 2-DoF flexible cable-driven mechanism. We propose a control that varies the intensity of the stretching, which was fixed in our previous study (Isobe et al., 2023), according to the individual, and to characterize the mechanical properties of the proposed mechanism. We also verify the feasibility of the proposed robot for scapular adduction/abduction assistance through experiments with younger and older adults. Methodology Scapular adduction/abduction support robot The overview of the proposed robot-assisted scapular stretching is shown in Figure 1. We propose a method to reproduce manual therapy shown in Figure 1(a) by using a wearable robot shown in Figure 1(c). Our method aims to reproduce manual therapy by modulating the pulling intensity based on shoulder reaction forces, as shown in Figure 1(b), providing robotic stretching for older adults. The proposed system dynamically supports scapular adduction by cable pulling while the elastic components of the shoulder brace passively facilitate the return motion to scapular abduction.Figure 1.(a) A physical therapist performing thoracic stretching. (b) Overview of the similarities between manual stretching and the proposed wearable robot to assist in thoracic stretching. The physical therapist grasps the shoulder and controls it based on the shoulder’s reaction force, while the proposed robot controls the shoulder, which is stabilized by a brace, based on the pulling force. (c) Overview of the proposed robot. Figure 1. long description.A three-panel diagram comparing manual thoracic stretching by a therapist and robotic-assisted stretching, with device components labeled. See long description. (a) A physical therapist performing thoracic stretching. (b) Overview of the similarities between manual stretching and the proposed wearable robot to assist in thoracic stretching. The physical therapist grasps the shoulder and controls it based on the shoulder’s reaction force, while the proposed robot controls the shoulder, which is stabilized by a brace, based on the pulling force. (c) Overview of the proposed robot. Figure 1. long description. First, we measured the trajectory of the humeral head during manual therapy by a physical therapist. The following describes the approximation process for determining the pulling direction based on a model with C7 as the origin, as shown in Figure 2(a). The position of the humeral head PHH(x1,y1,z1)bold italic upper P Subscript upper H upper H Baseline left parenthesis x 1 comma y 1 comma z 1 right parenthesis in 3-dimensional space represented by C7 as the origin is expressed by the following equation:(3.1) PHH=(x1y1z1)=(l1sin⁡θ1cos⁡ϕ1l1sin⁡θ1sin⁡ϕ1l1cos⁡θ1)bold italic upper P Subscript upper H upper H Baseline equals Start 3 By 1 Matrix 1st Row x 1 2nd Row y 1 3rd Row z 1 EndMatrix equals Start 3 By 1 Matrix 1st Row l 1 sine theta 1 cosine phi 1 2nd Row l 1 sine theta 1 sine phi 1 3rd Row l 1 cosine theta 1 EndMatrix P^HHModifyingAbove bold italic upper P With caret Subscript upper H upper H represents the approximated position of PHHbold italic upper P Subscript upper H upper H on a linear trajectory consisting of the normalized first principal components as follows:(3.2) P^HH=w1a1+uModifyingAbove bold italic upper P With caret Subscript upper H upper H Baseline equals w 1 bold a 1 plus bold u where a1bold a 1 denotes the normalized first principal component, w1w 1 denotes the weight value obtained from the principal component analysis of PHHbold italic upper P Subscript upper H upper H trajectory, and ubold u denotes the center of gravity of the trajectory, as shown in Figure 2(b). Assuming that the change in l1l 1 and lsl Subscript s is proportional when the distance from C7 to PHHbold italic upper P Subscript upper H upper H for another user is lsl Subscript s , the humeral head position PHHbold italic upper P Subscript upper H upper H can be expressed by the following equation:(3.3) P^HH=lsl1(w1a1+u)ModifyingAbove bold italic upper P With caret Subscript upper H upper H Baseline equals StartFraction l Subscript s Baseline Over l 1 EndFraction left parenthesis w 1 bold a 1 plus bold u right parenthesis The direction of this approximate line ( a1bold a 1 ) is assumed to be independent of the user’s body size. The pulling direction is fixed by adjusting the width and height of the cable guides according to the lsl Subscript s and l1l 1 . By controlling the cable pulling distance and tension with a cable-driven system using linear actuators, load cells, and Bowden cables, the 2-DoF robot can assist both scapular adduction/abduction simultaneously, as shown in Figure 3(a). When the distance from C7 to the cable guide is denoted as dd , the distance between the cable guides, ww , and the height from C7 to the cable guide, hh , are expressed by the following equations:(3.4) w=2|lsl1uy+|lsl1ux−d|a1ya1x|,h=lsl1uz+∣lsl1ux−d∣a1za1xw equals 2 StartAbsoluteValue StartFraction l Subscript s Baseline Over l 1 EndFraction u Subscript y Baseline plus EndAbsoluteValue StartFraction l Subscript s Baseline Over l 1 EndFraction u Subscript x Baseline minus d StartAbsoluteValue StartFraction a Subscript 1 y Baseline Over a Subscript 1 x Baseline EndFraction EndAbsoluteValue comma h equals StartFraction l Subscript s Baseline Over l 1 EndFraction u Subscript z Baseline plus StartAbsoluteValue StartFraction l Subscript s Baseline Over l 1 EndFraction u Subscript x Baseline minus d EndAbsoluteValue StartFraction a Subscript 1 z Baseline Over a Subscript 1 x Baseline EndFraction An example of the cable guide mounting positions is shown in Figure 3(b). The width and height of the cable guides are adjusted according to the C7 position. Bowden cables are also used to reduce friction between the cable and the cable guide. By using redundant wiring, the Bowden cable adapts to changes in the position of the cable guide. A flexible shoulder brace is used for connecting the body and the cable-driven system.Figure 2.(a) Shoulder link model. (b) Trajectory of the right humeral head and approximate line. PHHupper P Subscript upper H upper H : position of humeral head, P^HHModifyingAbove upper P With caret Subscript upper H upper H : approximated position of humeral head. Figure 2. long description.Two-panel schematic showing a shoulder link model with labeled humeral head position and a projected trajectory of the right humeral head compared to its approximate line. See long description. Figure 3.(a) Proposed robot configuration and cable guides positioning parameters. (b) The position of the cable guides. By adjusting the height and width of the cable guides, calculated by the shoulder width of the user, the pull direction of the cable-driven system can be aligned with the direction of movement of the user’s humeral head. Figure 3. long description.A four-panel technical diagram showing robot cable-driven system configuration and cable guide positioning relative to user anatomy. See long description. (a) Shoulder link model. (b) Trajectory of the right humeral head and approximate line. PHHupper P Subscript upper H upper H : position of humeral head, P^HHModifyingAbove upper P With caret Subscript upper H upper H : approximated position of humeral head. Figure 2. long description. (a) Proposed robot configuration and cable guides positioning parameters. (b) The position of the cable guides. By adjusting the height and width of the cable guides, calculated by the shoulder width of the user, the pull direction of the cable-driven system can be aligned with the direction of movement of the user’s humeral head. Figure 3. long description. It should be noted that the kinematic modeling of the humeral head described in this section is used only for hardware placement – specifically, to identify the optimal spatial arrangement of the cable guides in relation to individual anatomical landmarks. Since the current prototype cannot perform real-time shoulder position sensing, this model remains static and is not integrated into the active dynamic control loop. Shoulder brace The shoulder brace serves multiple functions beyond simply connecting the shoulder to the cable-driven system. The shoulder brace supports and stabilizes the shoulder joint, and the shoulder brace generally plays a role in pulling the shoulders toward the torso and preventing them from dropping downwards. Its function of restricting shoulder movement is used to achieve combined control around the shoulder joint. In addition, the torque required for shoulder motion varies with the angle of rotation of the upper arm (Kuechle et al., 1997). For example, Miyaguchi et al. (2008) attempted to support shoulder motion by CPM based on upper arm rotation measurements. The proposed robot uses a shoulder brace to prevent excessive upper arm inner/outer rotation change. Figure 4 shows a shoulder brace model and views of an older person wearing a brace. The shoulder brace is fixed with Velcro. Velcro is placed on the front of the body, making it easier for older adults to wear it alone. By pulling on the cable, the proposed robot can actively assist in scapular abduction, but releasing the cable does not actively assist in scapular abduction. Therefore, the braces on both sides are connected with elastic fabrics to passively support the movement of returning to the neutral posture during scapular abduction support.Figure 4.(a) Shoulder brace link model. The front elastic band passively supports scapular abduction. (b) An older person wearing a brace. Figure 4. long description.A two-panel layout with a labeled shoulder brace schematic on the left and three photos showing an older person wearing the brace from front, back, and side views. See long description. (a) Shoulder brace link model. The front elastic band passively supports scapular abduction. (b) An older person wearing a brace. Figure 4. long description. Control Review papers of the upper-limb control approach show that high-level interaction control strategies can be implemented in a range of methods, mainly including impedance/admittance-based strategies, adaptive control techniques, and physiological signal control (Rahman et al., 2010; Miao et al., 2018). The active motion of the scapula and the humeral head are modeled (FVD, 1994), but the passive joint ROM is unclear, so an intuitive and simple control method is required. Approaching the final ROM poses ethical safety concerns; therefore, our control strategy aims to apply high-intensity stretching tailored to the individual. Freitas et al. found a greater ROM in joint stretching with high-intensity loading than with low-intensity stretching (Freitas et al., 2016). Therefore, we refer to the physical therapist’s direction of movement based on our previous study (Isobe et al., 2023) and aim for stretching with force set at a high intensity to suit the individual. As described above in Section 1, the greater the amount of pull on the shoulder, the greater the load required. The tendency of change in load and distance changes significantly near the final ROM. Therefore, in this study, to achieve high-intensity stretching, the ROM is set by setting the maximum tension in advance, rather than by detecting the end-feel and setting the controlled ROM. Depending on the individual’s physique and flexibility, the maximum tension varies and is determined based on the user’s diagnosis. During practical stretching by the robot, the maximum tension is set as the target tension, and traction of the shoulder and adduction of the scapula are realized by position-based force control. When holding the stretching state after the target tension is reached, the difference between the target tension and the current tension is used as an input for position control to cope with fluctuations in shoulder reaction force. Since the robot is not equipped with a system for sensing the user’s shoulder position, the humeral head position used in the model described in Section 3.1 is not used for control. We adopted this position-based force control strategy because setting safety thresholds based on 3D shoulder posture is technically difficult due to the joint’s complex 3D kinematics. Furthermore, electromyography (EMG) was not used because it is difficult to distinguish the stretching state from passive tissue resistance using muscle activity alone. The robot operation is divided into two stages: the preparation and control processes. The preparation process aims to determine the individualized target tension Frefupper F Subscript ref based on user feedback. Following this, the control process executes a full stretching cycle consisting of three phases: loading, holding, and unloading. The preparation process is an empirical protocol for determining the individualized target tension Frefupper F Subscript ref for each user. As explained in Section 1, the force increases as the pulling distance increases according to the force–displacement properties of a joint. Therefore, we estimate the maximum pulling force by gradually pulling the brace while the user wears the device. The force at a distance considered appropriate by the user is set as the target tension Frefupper F Subscript ref . The robot’s control process strategy is mathematically described as follows. The control process performs stretching support based on the Frefupper F Subscript ref estimated in the preparation process. The robot uses a discrete-time, position-based force control method to ensure stable, safe stretching. The system updates the position command xrefx Subscript ref at each sampling interval based on the tension F[k]upper F left bracket k right bracket measured by load cells. At the start of the control process, the control logic for the next step k+1k plus 1 is expressed as follows:(3.5) xref[k+1]={xlimF[k]