From conventional to biosensor-based detection of Cryptosporidium spp. and Toxoplasma gondii in food and water: Implications for food and water safety Authors: Munwar Ali, Xiaohui Liang, Ali Raza, Chang Xu, Tingting Sun, Qing He, Zizye Zhu, Kun Li, Lizeng Peng Published: 2026 ABSTRACT Zoonotic food- and waterborne protozoan parasites (FWPPs) pose a significant global public health risk, causing substantial morbidity via contaminated fresh produce, water, and meat. Despite their notable impact, surveillance and detection technologies remain inadequate for high-priority protozoans such as Cryptosporidium spp. and Toxoplasma gondii, as current World Health Organization (WHO) and Food and Agriculture Organization (FAO) guidelines primarily focus on bacterial pathogens. This review evaluates the global burden of Cryptosporidium spp. and T. gondii, and highlights the limitations of conventional detection methods, justifying the forward-looking perspective on biosensors' applications in detecting protozoan parasites (PPs), and future strategies in this regard. The complex nature and varied transmission routes of these parasites, along with challenges such as culturing, sample preparation, and morphological similarities, complicate their detection by conventional methods like microscopy, serology, and molecular assays. Additionally, these limitations include time-intensive protocols, infrastructure requirements, cost, and lack of portability, which restrict their suitability for rapid, on-site detection. Recent advances in biosensor technology may offer rapid, sensitive, and accurate on-site detection of FWPPs, driving a paradigm shift toward a smart food safety system. This review highlights the potential of emerging biosensor technologies, especially electrochemical, optical, and piezoelectric (gravimetric) biosensors, for the detection of Cryptosporidium spp. and T. gondii in food and water. Integrating biosensors with nanotechnology, artificial intelligence, point-of-care systems and microfluidics to create portable, cost-effective biosensors may revolutionize food safety surveillance, mitigating the impact of FWPPs, and aligning with Hazard Analysis and Critical Control Points (HACCP) priorities to safeguard public health. Introduction Foodborne diseases impose a substantial global health burden, affecting an estimated 600 million people and causing approximately 420,000 deaths annually (WHO, U.N, 2015; WHO, 2021). Parasitic infections represent a major component of this morbidity, with global estimates for 2010 showing around 400 million individuals infected; notably, foodborne transmission accounts for approximately 91.1 million cases (22%) and 52,000 deaths each year (Chalmers et al., 2020; Torgerson et al., 2015). Among food- and waterborne protozoan parasites (FWPPs), Cryptosporidium spp. is a leading cause of diarrheal mortality, particularly in children under five (Khalil et al., 2018), while T. gondii causes significant morbidity through congenital infections, ocular disease, and life-threatening encephalitis in immunocompromised individuals (Montoya and Liesenfeld, 2004; Torgerson et al., 2015); both contaminate food and water with environmentally resistant oocysts (Fayer et al., 2000; Dubey, 2004). Furthermore, global climate shifts, including increased rainfall, elevate the risk of these PPs in water sources through terrestrial runoff and sewage bypasses, subsequently contaminating fruits and vegetables (Li et al., 2020a). Foodborne protozoan parasites pose a significant public health risk and are recognized in the International Organization for Standardization (ISO) standard (16140–2:2016/Amd 1:2024) (FAO, 2021; ISO (International Organization for Standardization), 2016a). Although the detection of Cryptosporidium spp. in food items is guided by ISO 18744:2016 (efficiency: 10–60% depending on matrix, limit of detection (LOD): ∼10–100 oocysts L−1), it suffers considerable constraints for routine analytical applications, including the analysis of complex matrices such as fruit juice (Chalmers et al., 2020; ISO (International Organization for Standardization), 2016b). Additionally, no standard ISO method currently exists for the detection of T. gondii in food products (Marín-García et al., 2022), creating a critical regulatory void in parasite surveillance. Unlike bacteria, Cryptosporidium spp. and T. gondii are difficult to cultivate in vitro, and their identification is challenging due to their complex life cycles, diverse hosts, and transmission routes, further complicated by overlapping characteristics shared across a vast range of protozoan species (Gabriël et al., 2022; Vinayak, 2020,Vinayak et al., 2020). Additionally, the diversity of food matrices in which parasites may occur, such as untreated milk, raw meat, contaminated vegetables, and fruits (ISO (International Organization for Standardization), 2016a, ISO (International Organization for Standardization), 2016b; FAO, 2021; WHO, U.N, 2015), together with variations in target identification, requirements for large sample volumes, and the complexities of sampling methods and associated preparation protocols, hinder accurate detection. Conventional detection methods for foodborne parasites such as T. gondii are constrained by challenges including variable DNA concentration and difficulties in parasite purification (Chalmers et al., 2020), often requiring days or weeks, involving significant time and financial investment (Di Nardo and Anfossi, 2020). Also, the detection of FWPPs is hindered by the inability to mass culture these protozoa, which limits the availability of standardized antigens. Moreover, antigenic variation across different life stages further restricts the development of reliable immunoassays (Feyziazar et al., 2022). To overcome these limitations, biosensor-based detection offers a promising alternative, utilizing diverse recognition elements, including aptamers (Iqbal et al., 2015; Hassan et al., 2021a; Siavash Moakhar et al., 2023), DNA probes (Gökce et al., 2016; Alves et al., 2017), synthetic receptors (Zhang et al., 2021; Sarkhosh et al., 2021), etc., bypassing the need for purified antigens while enabling rapid, sensitive, and portable analysis suitable for point-of-care (POC) testing (Luka et al., 2021; Yu et al., 2021; Lei et al., 2022). According to the International Union of Pure and Applied Chemistry (IUPAC), “a biosensor utilizes biochemical reactions, primarily involving enzymes, immune systems or cells, to detect a readable signal via electrical, thermal, magnetic or optical means”, underpinning POC testing (IUPAC, 2006). This review briefly examines the public health threats posed by Cryptosporidium spp. and T. gondii, acknowledging that while conventional detection methods (microscopy, PCR, immunoassays) remain analytically robust in terms of sensitivity and specificity and are essential for validating emerging detection technologies, they are constrained by time-intensive protocols, infrastructure requirements, and portability. We discuss how biosensor-based detection can complement these established methods by addressing gaps in portability and real-time analysis. We also assess the suitability of selected biosensors for rapid, accurate, and on-site detection of these protozoa, as well as their associated challenges and future perspectives in food safety and surveillance. Methodology for data searching and selection criteria The data synthesized in this review were retrieved from electronic databases (Google Scholar, Science Direct, Web of Science, PubMed, SCOPUS) and targeted field-specific journals. Keywords included biosensor types like electrochemical, optical (including colorimetric, fluorescence, surface plasmon resonance (SPR)), piezoelectric (gravimetric), and thermal, Cryptosporidium, T. gondii, and FWPPs, public health, detection, diagnostic limitations, CRISPR/Cas12a integration with biosensors, advancements in biosensors, and future perspectives in biosensor development for FWPPs. Given the rapidly evolving nature of biosensor technology, emphasis was placed on publications from 2015 to 2025, while seminal earlier works establishing foundational methodologies (e.g., ISO validation standards, gold-standard bioassays) were included to provide necessary technical context. Reference selection prioritized studies reporting analytical validation data, including LOD, specificity, matrix testing, and regulatory guidelines (WHO/FAO/ISO); covering electrochemical, optical, and piezoelectric transduction platforms, while ensuring representation of both prototype development and validation in complex food/water matrices (Fig. 1A, B).Fig. 1Schematic representation of (A) Word cloud visualization of key terms in the manuscript: It represents frequently used terms that encapsulate central themes of the given review article. The key terms are “biosensor, parasites detection, Cryptosporidium, T. gondii, food, sensitivity, and types of biosensors”, underscoring the basic focus of the whole manuscript. (B) Temporal distribution of reviewed publications: It represents the publication years of the included studies, with the majority between 2019 and 2025, reflecting a surge in research on the current topic in recent years. These trends highlight the growing scientific interest and emphasis on advancing the use of biosensor-based technologies for the detection of food- and waterborne protozoan parasites.Fig. 1 Schematic representation of (A) Word cloud visualization of key terms in the manuscript: It represents frequently used terms that encapsulate central themes of the given review article. The key terms are “biosensor, parasites detection, Cryptosporidium, T. gondii, food, sensitivity, and types of biosensors”, underscoring the basic focus of the whole manuscript. (B) Temporal distribution of reviewed publications: It represents the publication years of the included studies, with the majority between 2019 and 2025, reflecting a surge in research on the current topic in recent years. These trends highlight the growing scientific interest and emphasis on advancing the use of biosensor-based technologies for the detection of food- and waterborne protozoan parasites. T. gondii and Cryptosporidium spp. as significant food- and waterborne hazards As ∼70% of global water resources are linked to the agricultural sector, farm-based effluents frequently contaminate the natural ecosystems (Mateo-Sagasta et al., 2017; Wato, 2020). In Europe, 38% of water bodies are under significant pressure from agricultural pollution (Evans et al., 2019); hence, drinking water supplies and food products derived from food animals and fresh produce washed with contaminated water are at risk (WHO, U.N, 2015), elevating concerns about food- and waterborne pathogens, including PPs. An FAO/WHO Expert Committee reported 24 high-priority foodborne parasites globally (and 25 specifically for Europe in 2016), with Cryptosporidium spp. and T. gondii being of particular concern (FAO, 2021; WHO, U.N, 2015; Bouwknegt et al., 2018). These protozoa are often overlooked, yet they have caused a significant number of outbreaks in recent decades (Carstens et al., 2019). A recent systematic review and meta-analysis indicated that, based on available regional studies (predominantly from Asia and Africa), 41.22% of fruits and vegetables were contaminated with PPs, with Asia showing a notably high pooled prevalence of 57.12% (Eslahi et al., 2024), threatening global public health. Cryptosporidium spp. has been ranked fifth among 24 potential foodborne parasites (WHO, U.N, 2015). The Global Enteric Multicenter Study (GEMS) reported that it is the leading cause of diarrhea-associated mortality in children under five years of age in sub-Saharan Africa, second only to rotavirus (Chalmers et al., 2020; Kotloff et al., 2013). Sow et al. (2016) estimated approximately 202,000 Cryptosporidium-attributable deaths annually in children aged <24 months in sub-Saharan Africa and South Asia. In terms of measurable healthcare burden, in the US, an estimated 822,000 cases occur annually due to cryptosporidiosis as the leading cause of zoonotic enteric illness (CDC (Centers for Disease Control and Prevention), 2019). Similarly, in India, Cryptosporidium spp. results in 3.9–7.1 million diarrheal episodes in children under five (Sarkar et al., 2014). In the Netherlands, the annual disease burden was estimated at 50,000 cases, 300 hospitalizations, and €19.2 million in total costs of illness (Monge et al., 2019). The Global Burden of Disease (GBD) study 2016 reported that globally, Cryptosporidium spp. infection was associated with 4,224,000 Disability Adjusted Life Years (DALYs) and 57,203 deaths in children under five (Troeger et al., 2018). Recent surveillance data demonstrate a significant increase in reported cases, with a marked rise in Spain (Martinez et al., 2024) and an enhanced detection revealing endemicity in Denmark (Larsen et al., 2025). Food and waterborne outbreaks have occurred worldwide due to protozoan parasites (Fig. 2A) (Augendre et al., 2023). In South America, a recent study found Cryptosporidium spp. in 6.6% of strawberries, blackberries, and peaches (González-Ramírez et al., 2024). In Southeast England, 17% of ready-to-eat vegetable samples tested positive for C. parvum DNA by nested PCR (Suleiman et al., 2024). In Spain, Cryptosporidium spp. was found in 6.8% of lettuce, spinach, cabbage, and strawberry samples and in 7.8% of lettuce samples in another study (Moreno-Mesonero et al., 2023; Trelis et al., 2022). In Australia, 10% of arugula samples were reported to be contaminated with Cryptosporidium and Giardia spp. (Ng-Hublin et al., 2018). In Kuwait, 5% of arugula samples collected in 2023–2024 were contaminated with parasites, including Cryptosporidium spp. (Al-Awadhi and Iqbal, 2025). In China, Cryptosporidium spp. and Giardia were detected in 1.7% of vegetable samples collected between 2015 and 2017 (Li et al., 2020b). In Morocco, Cryptosporidium spp. was found in 3.03% of fresh produce, including carrots, coriander, lettuce, parsley, and radish collected between 2017 and 2018 (Berrouch et al., 2020), emphasizing the need for enhanced surveillance through rapid and on-site detection. In Germany, a study of 23 cryptosporidiosis cases with travel history to Croatia in August and September 2023 reported that 93% could be attributed to swimming pools as the most likely source of infection (Schoeps et al., 2024). From 2009 to 2017, over 444 cryptosporidiosis outbreaks were reported in the US alone, with 15% originating from contact with infected cattle and 12.8% from contact with infected individuals in child care settings (Gharpure et al., 2019). The largest waterborne outbreak due to Cryptosporidium spp. occurred in Milwaukee, Wisconsin (USA) (Mac Kenzie et al., 1994), costing US$96.2 million, including medical expenditures of US $31.7 million and productivity losses of US$64.6 million (Corso et al., 2003). Globally, Karanis et al. (2007) identified 165 Cryptosporidium-associated waterborne outbreaks occurring up to 2004, Baldursson and Karanis (2011) reported 120 outbreaks (60.3% of total waterborne protozoan outbreaks) between 2004 and 2010, Efstratiou et al. (2017) documented 239 outbreaks between 2011 and 2016, and Bourli et al. (2023) identified 322 outbreaks between 2017 and 2022, indicating a significant health threat.Fig. 2Transmission pathways of food- and waterborne protozoan parasites. (A) Cryptosporidium spp. transmission from infected hosts (livestock, humans) via oocyst shedding to water sources and agricultural produce (B) T. gondii transmission cycle: (1) Definitive hosts (felids) oocysts shed in feces; (2) Environmental sporulation and contamination of water/soil; (3) Ingestion by intermediate hosts (livestock, wildlife) or direct contamination of produce; (4) Human exposure via consumption of contaminated water, undercooked meat, and unwashed produce. Early detection at the environmental and food chain stages is critical for preventing human infection. Created in BioRender: https://BioRender.com/vowfth1, (License number: LU285QJ3XE).Fig. 2 Transmission pathways of food- and waterborne protozoan parasites. (A) Cryptosporidium spp. transmission from infected hosts (livestock, humans) via oocyst shedding to water sources and agricultural produce (B) T. gondii transmission cycle: (1) Definitive hosts (felids) oocysts shed in feces; (2) Environmental sporulation and contamination of water/soil; (3) Ingestion by intermediate hosts (livestock, wildlife) or direct contamination of produce; (4) Human exposure via consumption of contaminated water, undercooked meat, and unwashed produce. Early detection at the environmental and food chain stages is critical for preventing human infection. Created in BioRender: https://BioRender.com/vowfth1, (License number: LU285QJ3XE). Similarly, T. gondii ranks among the highly prevalent zoonotic parasites of humans, infecting up to one-third of the global human population (Montoya and Liesenfeld, 2004; Hussain et al., 2017). Transmission occurs principally via two distinct routes: ingestion of environmentally resistant oocysts, shed by felid definitive hosts into the environment, including water sources and onto fresh produce, or consumption of viable tissue cysts in undercooked meat from infected intermediate hosts (Fig. 2B). Infectious doses can be as low as 1–10 oocysts (Augendre et al., 2023; Dubey, 2021). Waterborne outbreaks have been documented in municipal drinking water supplies (Bowie et al., 1997; Aramini et al., 1999) and in endemic settings (de Moura et al., 2006). Notably, the largest waterborne toxoplasmosis outbreak occurred in Victoria, British Columbia, Canada in 1995, with an estimated 2894–7718 individuals infected when the Humpback Reservoir serving 219,000 people became contaminated with T. gondii oocysts from infected cat and cougar feces washed into the water supply by heavy rainfall (Bowie et al., 1997; Aramini et al., 1999). According to the FAO/WHO multicriteria global ranking of 14 foodborne parasites, T. gondii is the fourth most significant worldwide, based on disease burden measured in DALYs (FAO, 2021; WHO, U.N, 2015), and has been linked to several outbreaks. At the national level, it has ranked as the second most burdensome foodborne parasite in the United States (Batz et al., 2012; Hoffmann et al., 2012) and the leading one in the Netherlands (Havelaar et al., 2012). In a 2018 outbreak in the USA, 82% of individuals who consumed undercooked venison became ill (Schumacher et al., 2021). Similarly, in Quebec, Canada, an outbreak among deer hunters was linked to undercooked venison consumption, with 60% of the group developing symptoms (Gaulin et al., 2020). Ferreira et al. (2018) detected T. gondii in 12.9% of organic vegetable samples from Brazil, associating contamination with irrigation water sources and soil supplementation practices. In Europe, T. gondii was detected in 40% of watercress, lettuce, parsley, and different berry fruits in Portugal and Spain (Marques et al., 2020). T. gondii was also found in 3.6% of vegetable samples in China (Lass et al., 2019), and in 2020, 25% of sheep liver specimens were positive for T. gondii in Tunisia (Amdouni et al., 2024). All these studies clearly call for concern regarding early detection in food systems to control and prevent outbreaks. Conventional detection methods and their associated limitations Conventional detection methods for Cryptosporidium spp. Presently, the detection of Cryptosporidium spp. in food items is guided by ISO 18744:2016 (ISO (International Organization for Standardization), 2016b), an international standard based on microscopy alone; however, this approach is not ideal for routine analysis due to limitations in species or genotype identification and oocyst infectivity assessment (Chalmers et al., 2020). Additionally, US-EPA 1623.1 for water is widely used as the gold standard for Cryptosporidium detection, but a critical drawback is its suboptimal recovery efficiency (≤ 50%), attributed to significant oocyst losses during centrifugation, post-filtration and elution, as documented in comparative studies using immunomagnetic separation followed by immunofluorescence microscopy (IMS-IFM) (Fradette et al., 2022). Furthermore, no validated method exists for the detection of C. parvum in frozen foodstuffs, creating a gap in food safety assessments (Åberg et al., 2015). The US-EPA 1623.1 method employs IMS-IFM for oocyst identification, typically achieving recovery efficiencies of ≤50% (< 10% to >80%); however, this approach is costly and requires skilled personnel for accurate interpretation (Efstratiou et al., 2017; Siwak et al., 2023). Hence, for on-site and real-time detection, more practical and cost-effective methods are needed. Immunoassay-based methods for Cryptosporidium detection were developed to overcome the limitations associated with microscopy. The direct fluorescent antibody (DFA) assay, which uses fluorescein isothiocyanate-conjugated anti-Cryptosporidium monoclonal antibodies to bind the surface epitopes on oocysts and produce a yellow-green fluorescence, demonstrates 96–100% specificity and 98.5–100% sensitivity (Efstratiou et al., 2017). However, a drawback of DFA and other immunological assays is that commercially produced anti-Cryptosporidium monoclonal antibodies (mAbs) are raised against a limited pool of C. parvum isolates, and binding affinity may vary across species or genotypes, potentially making identification vague (Chalmers et al., 2020; Graczyk et al., 1996; Siwak et al., 2023). While DFA achieves 96–100% specificity, its detection limit typically ranges from 104 to 105 oocysts per gram (OPG) of environmental sample or fecal material, significantly higher than molecular methods (Efstratiou et al., 2017; Chalmers et al., 2020). Moreover, these standard methods cannot differentiate viable from non-viable oocysts without additional viability staining procedures (Brescia et al., 2009), exaggerating the actual public health risk. ELISA is predominantly used to detect Cryptosporidium spp. antigens in fecal samples, but due to the complexity of water samples and the typically low concentration of oocysts, ELISA is not directly applicable to water samples (Hassan et al., 2021b). Immunochromatographic lateral-flow assays have been developed for the rapid detection of Cryptosporidium in water and fecal samples; however, both ELISA and immunochromatographic strips may lead to false-positive results due to cross-reactivity with non-target organisms (Chalmers et al., 2020; Garcia and Shimizu, 1997; Siwak et al., 2023). Also, molecular detection methods for Cryptosporidium spp. face multiple technical and methodological limitations. The primer design remains a critical challenge, particularly regarding real-time PCR, as non-specific amplifications from food matrices such as raspberries and iceberg lettuce have been shown to yield variable results in ring trials, necessitating post-PCR verifications such as sequencing to confirm target specificity, especially when targeting conserved regions like the 18S gene (Chalmers et al., 2020; Fradette et al., 2022). Furthermore, molecular methods, including nested PCR and RT-PCR, demand specialized equipment, technical expertise and costly reagents, limiting scalability (Mahmudunnabi et al., 2024; O'Leary et al., 2021). Analytically, PCR-based methods achieve detection limits of 1–10 oocysts per reaction in purified water samples; however, in complex food matrices (e.g., raspberries, lettuce), practical LODs often rise to 102–103 OPG due to extraction losses, PCR inhibition by humic acids and co-contaminants (Fradette et al., 2022; Mahmudunnabi et al., 2024). Conventional detection methods for T. gondii Despite the significant public health threat posed by T. gondii, standardized methods for detecting the parasite across diverse food matrices contaminated with different life stages (tachyzoites, bradyzoites, oocysts) remain unavailable (Marín-García et al., 2022). A gold standard test for confirming T. gondii viability in meat tissue is the bioassay, which recovers viable tachyzoites or bradyzoites. While the mouse or cat bioassay can theoretically detect as few as 10 tachyzoites, the 6-week incubation period and ethical constraints limit its practical utility for large-scale studies (Opsteegh et al., 2020). Cell culture methods (e.g., human foreskin fibroblasts) offer alternatives but exhibit lower sensitivity than bioassays (Opsteegh et al., 2020). In contrast, no equivalent method exists for oocysts, and their isolation and concentration from complex matrices such as raw vegetables remain hindered by the lack of precise and efficient laboratory techniques (Eslahi et al., 2024). Light microscopy enables identification but carries low sensitivity and requires skilled personnel (Liu et al., 2015) and risks false-positive results due to morphological similarities between oocysts and food-derived debris (Fig. 3) (Eslahi et al., 2024).Fig. 3A detailed outline demonstrating the transition from conventional detection methods to a biosensor-based approach for FWPPs. The top panel highlights the conventional detection methods (from microscopy to biochemical assays) along with their associated limitations, while the bottom panel illustrates the benefits of biosensor-based technologies, emphasizing the significance of the above-mentioned shift in food safety and surveillance by overcoming the constraints of traditional detection techniques. Created in BioRender: https://BioRender.com/vf1vn1y, (License number: OS285QLYVL).Fig. 3 A detailed outline demonstrating the transition from conventional detection methods to a biosensor-based approach for FWPPs. The top panel highlights the conventional detection methods (from microscopy to biochemical assays) along with their associated limitations, while the bottom panel illustrates the benefits of biosensor-based technologies, emphasizing the significance of the above-mentioned shift in food safety and surveillance by overcoming the constraints of traditional detection techniques. Created in BioRender: https://BioRender.com/vf1vn1y, (License number: OS285QLYVL). Molecular detection of T. gondii is limited by technical constraints. Magnetic capture qPCR (MC-qPCR), though validated for T. gondii tissue cysts in pork (Fig. 3) (Abhari et al., 2023; Algaba et al., 2017), remains underutilized. Conventional PCR targeting the B1 gene in water and meat indicated that 90% of samples were positive for T. gondii (Useche et al., 2022), with reported detection limits of 65.4 tachyzoites per 100 g of meat (Algaba et al., 2017; Useche et al., 2022). Assays targeting single-copy genes (e.g., B1) show reduced sensitivity compared to multi-copy targets (e.g., 529-bp repeat element) due to low genomic copy number, particularly in complex food matrices (Reischl et al., 2003). In addition, real-time PCR requires expensive instrumentation (Abhari et al., 2023). These PCR-based methods are primarily used for detection. In outbreak investigations, PCR detection was successfully applied during the 1995 Victoria, British Columbia waterborne toxoplasmosis outbreak to isolate and characterize T. gondii from contaminated reservoir water (Aramini et al., 1999; Bowie et al., 1997). Later, multilocus PCR-RFLP genotyping identified the type I strain responsible for the 2001 toxoplasmosis outbreak in Brazil linked to contaminated water (de Moura et al., 2006). For detection in water, oocysts are typically concentrated by filtration, followed by molecular detection, though standardized methods are lacking compared to Cryptosporidium (Karanis et al., 2007; Dumètre et al., 2013). These constraints emphasize the need for biosensor-based approaches to identify PPs in contaminated water and food matrices. A shift from conventional to biosensor-based detection for PPs Overview, working principle, and classification of biosensors Biosensors are analytical devices that can overcome the limitations of conventional testing methods by enabling rapid, precise, and sensitive detection of pathogens. Portable and cost-effective biosensors provide real-time monitoring of food quality and manufacturing process, combining high sensitivity, rapidity, and accuracy for tracking pathogens or their metabolic byproducts (Turasan and Kokini, 2021; Yasmin et al., 2016). The recognition element (RE) identifies analytes in complex samples, the transducer translates the biological response into a measurable output, and the processor presents interpretable data (Fig. 4).Fig. 4Schematic presentation of biosensor-based detection methods to detect FWPPs. Biosensor systems integrate recognition elements (enzymes, antibodies, aptamers, phages, etc.) with transducers (optical, electrochemical, gravimetric, magnetic) to convert analytes (antigens, DNA, parasites) into measurable signals. Applications span food safety diagnosis, pathogen detection, and water hazard monitoring. Created in BioRender: https://BioRender.com/sj3iim2, (HO285QML8O).Fig. 4 Schematic presentation of biosensor-based detection methods to detect FWPPs. Biosensor systems integrate recognition elements (enzymes, antibodies, aptamers, phages, etc.) with transducers (optical, electrochemical, gravimetric, magnetic) to convert analytes (antigens, DNA, parasites) into measurable signals. Applications span food safety diagnosis, pathogen detection, and water hazard monitoring. Created in BioRender: https://BioRender.com/sj3iim2, (HO285QML8O). Biosensors are classified by RE, including antibiotic (Byrne et al., 2009; Sande et al., 2021), antibody (Byrne et al., 2009; Crivianu-Gaita and Thompson, 2016), aptamer (Crivianu-Gaita and Thompson, 2016; Hianik et al., 2024; Xiao et al., 2021), bacteriophage (Al-Hindi et al., 2022), DNA/RNA (Techakasikornpanich et al., 2024), enzyme (Vaidya and Annapure, 2019), lectin (Mi et al., 2021), molecularly imprinted polymer (MIP) (Zhang et al., 2021), and whole cell (Wu et al., 2021) types. They can also be classified by transducer type: electrochemical (amperometric, impedimetric, potentiometric, and voltammetric) (Singh et al., 2021), gravimetric (Cali et al., 2020), optical (e.g., SPR) (Chen and Wang, 2020), magnetic (Turasan and Kokini, 2021; Yasmin et al., 2016) or thermal (Ramanathan and Danielsson, 2001) (Fig. 4). Biosensor classifications also include genosensors (DNA/RNA detection), immunosensors (proteins/antibodies), and aptasensors (Davis and Higson, 2012; Felix and Angnes, 2018; Hosu et al., 2018), thereby encompassing a wide range of recognition strategies. Although advancements in biosensor development for detecting foodborne pathogens (bacteria, viruses) and toxins (mycotoxins) have been made in recent years (Banakar et al., 2022; Eyvazi et al., 2021; Hjort et al., 2024), a research gap persists regarding the use of biosensor technology for the detection of zoonotic PPs like Cryptosporidium spp. and T. gondii in food and water matrices. Types of biosensors aimed at detecting Cryptosporidium spp. in food and water samples Electrochemical biosensors Electrochemical sensors, a pivotal analytical tool, function by interfacing chemical solutions with sensor systems to generate electrical signals proportional to analyte concentrations. Due to the small size of Cryptosporidium, usually a chemical agent is used to amplify the electrochemical signal to a detectable level, as the organism covers a small portion of the electrode surface and imparts only a slight difference in current variations at the electrode-electrolyte surface. It involves a biorecognition element (e.g., aptamer, enzyme, antibody) that binds to target analyte (e.g., Cryptosporidium oocysts), followed by transduction, which includes different methods like electrochemical impedance spectroscopy (EIS), which measures changes in charge transfer resistance (Luka et al., 2022); voltammetry (square wave voltammetry/differential pulse voltammetry), which recognizes current changes resulting from redox reactions (Iqbal et al., 2015); and capacitance, which detects dielectric changes at the electrode-solution interface when the analyte binds to immobilized receptors (Luka et al., 2019). Finally, the electrical output (current and impedance) is quantified and correlated with analyte concentration with high sensitivity. Current platforms integrate nanomaterials, such as gold nanoparticles (AuNPs), to amplify signals (Iqbal et al., 2019). These approaches are beneficial due to their ability to detect electrochemical responses at specified reduction potentials, ensuring specificity and precision (Hasanzadeh et al., 2018; Nemati et al., 2023; Safarpour et al., 2020; Singh et al., 2021). Impedance spectroscopy-based electrochemical biosensor Due to their cost-effectiveness, miniaturized EIS systems are used to construct biosensor chips. A significant feature of these types of biosensors is label-free detection. In this biosensor type, impedance is measured by applying an AC potential to an electrochemical cell, and the current and resistance across the system are measured according to Ohm's law (Khare et al., 2022). In this context, Luka et al. (2022) developed a fast, cost-effective, on-chip electrochemical sensor with high sensitivity for detecting Cryptosporidium oocysts. The equipment includes a gold electrode functionalized with anti-Cryptosporidium mAbs (IgG3 subclass) immobilized via thiolated protein G (Fig. 5). By measuring changes in charge-transfer resistance, this biosensor achieves a detection limit of 20 oocysts in a 5 μL detection volume. While environmental waters require pre-concentration from larger volumes (standard practice in parasitological monitoring), this sensitivity enables rapid, label-free confirmation of Cryptosporidium spp. in concentrated water samples or high-risk matrices, supporting early warning systems for waterborne outbreaks (Table 1).Fig. 5The modified sensor surface was analyzed by CV, SWV, and EIS. In the absence of Cryptosporidium spp. oocysts, the [Fe(CN)₆]3−/4− redox probe diffuses through the monolayer to access the working electrode (WE) surface, where its oxidation/reduction generates a detectable charge transfer current. Conversely, the presence of oocysts blocks the monolayer, increasing the film's resistance and hindering electron transfer. This disruption is quantified via EIS, which reveals elevated impedance due to oocysts-induced interference. Adapted from (Luka et al., 2022), Sci Rep 12:6957. https://doi.org/10.1038/s41598-022-10765-0. Licensed under CC BY 4.0 (https://creativecommons.org/licenses/by/4.0/).Fig. 5Table 1Different biosensors with transducers, chip types, LODss, and linear/dynamic ranges for the detection of Cryptosporidium spp.AnalyteType of sensorTransducerType of chip (electrode)LODLinear/dynamic rangeSourceReferenceC. parvumImmunosensorElectrochemical sensorScreen-printed carbon electrodes2 × 104 oocysts mL−1Not reportedGround beef(Nze et al., 2019)C. parvumImmunosensorOptical microfluidic biosensorMicrofluidic chip based on an immune agglutination assay100 to 101 oocysts mL−1100 to 104 oocysts mL−1Water sample(Angus et al., 2012b)C. parvumImmunosensorOptical (colorimetric, enzymatic amplification + AuNP signal enhancement)Not reported (nitrocellulose membrane)10 oocysts mL−13 to 200 oocysts mL−1Water samples(Thiruppathiraja et al., 2011a)Cryptosporidium spp.ImmunosensorSandwich enzyme-linked electrochemical biosensorIndium Tin Oxide (ITO) electrode3 oocysts mL−15–100 oocysts mL−1Water samples(Thiruppathiraja et al., 2011b)C. parvumImmunosensorOptical SPR biosensorGold-coated, polyclonal anti-mouse IgM arrayed SPR sensor chip1 × 102 oocysts mL−11 × 106 to 1 × 102 oocysts mL−1Natural water systems(Kang et al., 2008)Cryptosporidium spp.Immunosensor (labeled)Evanescent wave fiber (optic chemical sensor)R Plus 4Sb105 oocysts mL−1106 oocysts mL−1Water sample(Kramer et al., 2007)C. parvumImmunosensorPiezoelectric electrochemical sensorQuartz crystal microbalance3 × 105 to 107 oocysts mL−13 × 105 to 1 × 107 oocysts mL−1Water sample(Poitras et al., 2009)C. parvumImmunosensorEIS, CV, SWVMicrofabricated; thiolated gold electrodes20 oocysts /5 μL0 to 300 oocystsWater sample(Luka et al., 2022)C. parvumImmunosensorCVInterdigitated gold electrodes40 cells/mm215 to 153 cells/mm2Water sample(Luka et al., 2019)C. parvumImmunosensorEISInterdigitated micro-electrode10 cells μL−11.43433 × 10−5 × C + 7.545921 × 10−4Water sample(Houssin et al., 2010)C. parvumImmunosensorPiezoelectric-excited millimeter-sized cantilever (PEMCn)PZTe and glass film102, 103, and 104 oocysts mL−1102 to 104 oocysts mL−1Drinking water(Campbell and Mutharasan, 2008)C. parvumImmunosensorColorimetric detection (non-labeling fluorescence sensor)Polydiacetylene-based fluorescence chip1 × 103 oocysts mL−11 × 102 to 1 × 105 oocysts mL−1Water sample(Park et al., 2008)C. parvumImmunosensor (FITC-labeled antibody-based)Optical (Fluorescence detection via microscope)PDMSm microfluidic device integrated with a SUSi micromesh10 oocysts mL−118–200 oocysts mL−1Contaminated water(Taguchi et al., 2007)C. parvumImmunosensorOptical SPR biosensorGold chip1 × 106 oocysts mL−1Not reportedOocyst Stock Waterborne, Inc. (USA)(Kang et al., 2006)C. parvumCRISPR/Cas12a-powered immunosensorFluorescence plate readerNot reported (streptavidin-coated 96-well plate with biotinylated antibody capture interface)Single oocyst per sample (∼10 oocysts mL−1)6.25 to 1600 oocysts mL−1Water sample(Li et al., 2021)C. parvum hsp70 mRNAGenosensorOptical/colorimetric transducerPMMA microfluidic chip with surface modifications30 oocystsNot reportedCommercial oocysts (Waterborne Inc.)(Reinholt et al., 2014)Cryptosporidium spp.GenosensorOptical; colorimetric (camera for signal transmission)Micro-fabricated chip; thiolated oligonucleotides/AuNPs (sensing probe)5.0 μM5 to 100 μMWater (Cryptosporidium RNA)(Luka et al., 2021)Cryptosporidium spp. DNAGenosensorElectrochemical DPVd and EIS3D μTASf1.8 ng mL−12.5 ng mL−1 - 0.1 μg mL−1Cryptosporidium DNA(Ilkhani et al., 2019)C. parvumGenosensorAmperometric electrochemical biosensorIDUA integrated with a gold electrode1 oocyst mL−1Not reportedC. parvum oocyst DNA(Nugen et al., 2009)C. parvumSolution-phase genosensorNanoparticle-based optical sensorAuNP Probes670 oocysts μL−1 reaction mix4 × 105 and 4 × 106 copies of RNA μL−1Stool sample (100 mg)(Weigum et al., 2013)C. parvum, G. duodenalis, E. coli, and impuritiesOptical sensorOptical (CMOSj camera; PMTk for triggering)Glass microfluidic chipNot reported3000 parasites/min at a flow rate of 12 μL/min (accuracy >96%)Contaminated water(Huang et al., 2017)C. parvumOptical SPR biosensorPlasmonic multilayer structurePrism-coupled SPR chip with Ag, TiO₂, and MXene layers3 × 10−5 RIUaNot reportedContaminated water(Daher et al., 2025)C. parvumOptical sensor using DIHM*650 nm laser and CMOS* cameraNot reported (3.5 mL optical glass cuvette)0.33 oocysts mL−10.3 to 300 oocysts mL−1Lab-cultured Iowa isolate oocysts(Thompson et al., 2020)C. parvum, G. duodenalisLabel-free optical biosensor (100% accuracy)Optical (DPMl system with a CCD camera)PDMSm microfluidic chipNot reportedNot reportedDrinking water(Gu et al., 2019)C. parvumElectrochemical aptasensorSWV with GNP-SPCE⁎Not reported (SPCE modified with gold nanoparticles)∼103 oocystsmL−150 to 900 oocystsDrinking and recreational water(Iqbal et al., 2019)C. parvumElectrical impedance biosensorIMAso functionalized with HCT-8 cellsGold-coated Pyrex substrate with IMAso1 × 102 oocysts mL−11 × 102 to 1 × 106 oocysts mL−1Oocysts from Waterborne Inc. (New Orleans, LA, USA), Iowa strain(Dibao-Dina et al., 2015)C. parvumAptamerCV, EIS, chronocoulometry3D gold NMI*103 to 104 oocysts mL−1101 to 105 oocysts mL−1Oocysts retrieved from buffer, tap water, and stool(Siavash Moakhar et al., 2023)Cryptosporidium spp.Aptamer-conjugated magnetic beadsNot reported (flow cytometry and fluorescence microplate-based assay)Not reported (uses micro-magnetic beads)5 oocysts/300 μLNot reportedWaste sample(Hassan et al., 2021a)C. parvumAptasensorSWVScreen-printed carbon electrode100 oocysts mL−1200 to 700 oocysts mL−1Fresh fruits(Iqbal et al., 2015)C. parvumAntibodies and aptamersColorimetric/ fluorescence detectionNot reported (syringe filters)1 × 105 oocysts mL−11 × 103 to 1 × 108 oocysts mL−1Recreational water(Ruiz-andino, 2022)Cryptosporidium spp.IMS combined LAMPh-based detectionFluorescence and colorimetric detectionMagnetic beads functionalized with anti-Cryptosporidium monoclonal antibodies for target capture)5 to 10 oocysts per 10 mL5 to 1000 oocysts per 10 mLCommercial oocysts (from Biopoint Pty. Ltd., Sydney)(Mahmudunnabi et al., 2025)C. parvumCIPp biosensorFluorescence microscopy (staining with the Crypt-a-Glo antibody kit and DAPIr for oocyst visualization).PDMSm surfaces100 oocysts mL−1100 to 100,000 oocysts mL−1Lab-cultured Iowa isolate(Sarkhosh et al., 2021)RIUa: Refractive index unit; R Plus 4Sb: RAPTOR Plus 4S; NMIc: Nano−/microisland; DPVd: Differential pulse voltammetry 0.0375 to 1.2 AU mL−1and 2.0 to 18 AU mL−1, PZTe: Lead Zirconate Titanate; 3D μTASf: Three-dimensional micro total analysis systems; GNP-SPCEg: Gold nanoparticle-modified screen-printed carbon electrode; LAMPh: Loop-mediated isothermal amplification-based detection; SUSi: Special use stainless 304; CMOSj: Complementary metal-oxide-semiconductor; PMTk: Photomultiplier tube; DPMl: Diffraction phase microscopy; PDMSm: Polydimethylsiloxane; PEMCn: Piezoelectric-excited millimeter-sized cantilever; IMAso: Interdigitated Microelectrode Arrays; CIPp: Cell-imprinted polymer; DIHMq: Digital inline holographic microscopy; DAPIr: 4′,6-diamidino-2-phenylindole. Note: LODs represent analytical sensitivities determined primarily under optimized laboratory conditions using spiked samples (typically 5–100 μL volumes). The modified sensor surface was analyzed by CV, SWV, and EIS. In the absence of Cryptosporidium spp. oocysts, the [Fe(CN)₆]3−/4− redox probe diffuses through the monolayer to access the working electrode (WE) surface, where its oxidation/reduction generates a detectable charge transfer current. Conversely, the presence of oocysts blocks the monolayer, increasing the film's resistance and hindering electron transfer. This disruption is quantified via EIS, which reveals elevated impedance due to oocysts-induced interference. Adapted from (Luka et al., 2022), Sci Rep 12:6957. https://doi.org/10.1038/s41598-022-10765-0. Licensed under CC BY 4.0 (https://creativecommons.org/licenses/by/4.0/). Table 1Different biosensors with transducers, chip types, LODss, and linear/dynamic ranges for the detection of Cryptosporidium spp.AnalyteType of sensorTransducerType of chip (electrode)LODLinear/dynamic rangeSourceReferenceC. parvumImmunosensorElectrochemical sensorScreen-printed carbon electrodes2 × 104 oocysts mL−1Not reportedGround beef(Nze et al., 2019)C. parvumImmunosensorOptical microfluidic biosensorMicrofluidic chip based on an immune agglutination assay100 to 101 oocysts mL−1100 to 104 oocysts mL−1Water sample(Angus et al., 2012b)C. parvumImmunosensorOptical (colorimetric, enzymatic amplification + AuNP signal enhancement)Not reported (nitrocellulose membrane)10 oocysts mL−13 to 200 oocysts mL−1Water samples(Thiruppathiraja et al., 2011a)Cryptosporidium spp.ImmunosensorSandwich enzyme-linked electrochemical biosensorIndium Tin Oxide (ITO) electrode3 oocysts mL−15–100 oocysts mL−1Water samples(Thiruppathiraja et al., 2011b)C. parvumImmunosensorOptical SPR biosensorGold-coated, polyclonal anti-mouse IgM arrayed SPR sensor chip1 × 102 oocysts mL−11 × 106 to 1 × 102 oocysts mL−1Natural water systems(Kang et al., 2008)Cryptosporidium spp.Immunosensor (labeled)Evanescent wave fiber (optic chemical sensor)R Plus 4Sb105 oocysts mL−1106 oocysts mL−1Water sample(Kramer et al., 2007)C. parvumImmunosensorPiezoelectric electrochemical sensorQuartz crystal microbalance3 × 105 to 107 oocysts mL−13 × 105 to 1 × 107 oocysts mL−1Water sample(Poitras et al., 2009)C. parvumImmunosensorEIS, CV, SWVMicrofabricated; thiolated gold electrodes20 oocysts /5 μL0 to 300 oocystsWater sample(Luka et al., 2022)C. parvumImmunosensorCVInterdigitated gold electrodes40 cells/mm215 to 153 cells/mm2Water sample(Luka et al., 2019)C. parvumImmunosensorEISInterdigitated micro-electrode10 cells μL−11.43433 × 10−5 × C + 7.545921 × 10−4Water sample(Houssin et al., 2010)C. parvumImmunosensorPiezoelectric-excited millimeter-sized cantilever (PEMCn)PZTe and glass film102, 103, and 104 oocysts mL−1102 to 104 oocysts mL−1Drinking water(Campbell and Mutharasan, 2008)C. parvumImmunosensorColorimetric detection (non-labeling fluorescence sensor)Polydiacetylene-based fluorescence chip1 × 103 oocysts mL−11 × 102 to 1 × 105 oocysts mL−1Water sample(Park et al., 2008)C. parvumImmunosensor (FITC-labeled antibody-based)Optical (Fluorescence detection via microscope)PDMSm microfluidic device integrated with a SUSi micromesh10 oocysts mL−118–200 oocysts mL−1Contaminated water(Taguchi et al., 2007)C. parvumImmunosensorOptical SPR biosensorGold chip1 × 106 oocysts mL−1Not reportedOocyst Stock Waterborne, Inc. (USA)(Kang et al., 2006)C. parvumCRISPR/Cas12a-powered immunosensorFluorescence plate readerNot reported (streptavidin-coated 96-well plate with biotinylated antibody capture interface)Single oocyst per sample (∼10 oocysts mL−1)6.25 to 1600 oocysts mL−1Water sample(Li et al., 2021)C. parvum hsp70 mRNAGenosensorOptical/colorimetric transducerPMMA microfluidic chip with surface modifications30 oocystsNot reportedCommercial oocysts (Waterborne Inc.)(Reinholt et al., 2014)Cryptosporidium spp.GenosensorOptical; colorimetric (camera for signal transmission)Micro-fabricated chip; thiolated oligonucleotides/AuNPs (sensing probe)5.0 μM5 to 100 μMWater (Cryptosporidium RNA)(Luka et al., 2021)Cryptosporidium spp. DNAGenosensorElectrochemical DPVd and EIS3D μTASf1.8 ng mL−12.5 ng mL−1 - 0.1 μg mL−1Cryptosporidium DNA(Ilkhani et al., 2019)C. parvumGenosensorAmperometric electrochemical biosensorIDUA integrated with a gold electrode1 oocyst mL−1Not reportedC. parvum oocyst DNA(Nugen et al., 2009)C. parvumSolution-phase genosensorNanoparticle-based optical sensorAuNP Probes670 oocysts μL−1 reaction mix4 × 105 and 4 × 106 copies of RNA μL−1Stool sample (100 mg)(Weigum et al., 2013)C. parvum, G. duodenalis, E. coli, and impuritiesOptical sensorOptical (CMOSj camera; PMTk for triggering)Glass microfluidic chipNot reported3000 parasites/min at a flow rate of 12 μL/min (accuracy >96%)Contaminated water(Huang et al., 2017)C. parvumOptical SPR biosensorPlasmonic multilayer structurePrism-coupled SPR chip with Ag, TiO₂, and MXene layers3 × 10−5 RIUaNot reportedContaminated water(Daher et al., 2025)C. parvumOptical sensor using DIHM*650 nm laser and CMOS* cameraNot reported (3.5 mL optical glass cuvette)0.33 oocysts mL−10.3 to 300 oocysts mL−1Lab-cultured Iowa isolate oocysts(Thompson et al., 2020)C. parvum, G. duodenalisLabel-free optical biosensor (100% accuracy)Optical (DPMl system with a CCD camera)PDMSm microfluidic chipNot reportedNot reportedDrinking water(Gu et al., 2019)C. parvumElectrochemical aptasensorSWV with GNP-SPCE⁎Not reported (SPCE modified with gold nanoparticles)∼103 oocystsmL−150 to 900 oocystsDrinking and recreational water(Iqbal et al., 2019)C. parvumElectrical impedance biosensorIMAso functionalized with HCT-8 cellsGold-coated Pyrex substrate with IMAso1 × 102 oocysts mL−11 × 102 to 1 × 106 oocysts mL−1Oocysts from Waterborne Inc. (New Orleans, LA, USA), Iowa strain(Dibao-Dina et al., 2015)C. parvumAptamerCV, EIS, chronocoulometry3D gold NMI*103 to 104 oocysts mL−1101 to 105 oocysts mL−1Oocysts retrieved from buffer, tap water, and stool(Siavash Moakhar et al., 2023)Cryptosporidium spp.Aptamer-conjugated magnetic beadsNot reported (flow cytometry and fluorescence microplate-based assay)Not reported (uses micro-magnetic beads)5 oocysts/300 μLNot reportedWaste sample(Hassan et al., 2021a)C. parvumAptasensorSWVScreen-printed carbon electrode100 oocysts mL−1200 to 700 oocysts mL−1Fresh fruits(Iqbal et al., 2015)C. parvumAntibodies and aptamersColorimetric/ fluorescence detectionNot reported (syringe filters)1 × 105 oocysts mL−11 × 103 to 1 × 108 oocysts mL−1Recreational water(Ruiz-andino, 2022)Cryptosporidium spp.IMS combined LAMPh-based detectionFluorescence and colorimetric detectionMagnetic beads functionalized with anti-Cryptosporidium monoclonal antibodies for target capture)5 to 10 oocysts per 10 mL5 to 1000 oocysts per 10 mLCommercial oocysts (from Biopoint Pty. Ltd., Sydney)(Mahmudunnabi et al., 2025)C. parvumCIPp biosensorFluorescence microscopy (staining with the Crypt-a-Glo antibody kit and DAPIr for oocyst visualization).PDMSm surfaces100 oocysts mL−1100 to 100,000 oocysts mL−1Lab-cultured Iowa isolate(Sarkhosh et al., 2021)RIUa: Refractive index unit; R Plus 4Sb: RAPTOR Plus 4S; NMIc: Nano−/microisland; DPVd: Differential pulse voltammetry 0.0375 to 1.2 AU mL−1and 2.0 to 18 AU mL−1, PZTe: Lead Zirconate Titanate; 3D μTASf: Three-dimensional micro total analysis systems; GNP-SPCEg: Gold nanoparticle-modified screen-printed carbon electrode; LAMPh: Loop-mediated isothermal amplification-based detection; SUSi: Special use stainless 304; CMOSj: Complementary metal-oxide-semiconductor; PMTk: Photomultiplier tube; DPMl: Diffraction phase microscopy; PDMSm: Polydimethylsiloxane; PEMCn: Piezoelectric-excited millimeter-sized cantilever; IMAso: Interdigitated Microelectrode Arrays; CIPp: Cell-imprinted polymer; DIHMq: Digital inline holographic microscopy; DAPIr: 4′,6-diamidino-2-phenylindole. Note: LODs represent analytical sensitivities determined primarily under optimized laboratory conditions using spiked samples (typically 5–100 μL volumes). Different biosensors with transducers, chip types, LODss, and linear/dynamic ranges for the detection of Cryptosporidium spp. RIUa: Refractive index unit; R Plus 4Sb: RAPTOR Plus 4S; NMIc: Nano−/microisland; DPVd: Differential pulse voltammetry 0.0375 to 1.2 AU mL−1and 2.0 to 18 AU mL−1, PZTe: Lead Zirconate Titanate; 3D μTASf: Three-dimensional micro total analysis systems; GNP-SPCEg: Gold nanoparticle-modified screen-printed carbon electrode; LAMPh: Loop-mediated isothermal amplification-based detection; SUSi: Special use stainless 304; CMOSj: Complementary metal-oxide-semiconductor; PMTk: Photomultiplier tube; DPMl: Diffraction phase microscopy; PDMSm: Polydimethylsiloxane; PEMCn: Piezoelectric-excited millimeter-sized cantilever; IMAso: Interdigitated Microelectrode Arrays; CIPp: Cell-imprinted polymer; DIHMq: Digital inline holographic microscopy; DAPIr: 4′,6-diamidino-2-phenylindole. Note: LODs represent analytical sensitivities determined primarily under optimized laboratory conditions using spiked samples (typically 5–100 μL volumes). Label-free affinity capacitive biosensor Capacitive biosensors guarantee label-free, ultrasensitive detection of biomarkers by measuring capacitive variations from biomarker-bioreceptor interactions. Consisting of bioreceptors and transducers, the dielectric layer changes due to binding events, translating into measurable signals. Owing to their high sensitivity and low cost, these are ideally used for food safety monitoring. The transducers employ gold (AuEs), carbon (CEs), or interdigitated electrodes (IDEs) to immobilize the bioreceptor and generate a detectable capacitive signal (Huang et al., 2024). Luka et al. (2019) developed a label-free capacitive biosensor using interdigitated gold electrodes to detect Cryptosporidium oocysts in water. The platform incorporated a capture probe, anti-Cryptosporidium mAbs (IgG3), and bovine serum albumin (BSA) to enhance specificity (Table 1) (Luka et al., 2019). Cryptosporidium detection workflow included coating the sensing electrodes with anti-Cryptosporidium antibodies and incubation with water samples containing varying oocyst concentrations; washing with phosphate-buffered saline (PBS, pH 7.0) to remove unbound or nonspecific molecules; drying the IDEs under controlled conditions; and capacitance measurements performed across a specific frequency range to quantify oocyst binding. Future work needs to be focused on electrode material, immobilization techniques, and signal implications to enhance their performance. Electrochemical aptasensor Aptamers are synthetic single-stranded DNA/RNA oligonucleotides, designed to bind specific target molecules with high affinity. Aptamers are commonly selected by systematic evolution of ligands by exponential enrichment (SELEX). Aptamers are frequently used in diagnostics and biosensors, including for Cryptosporidium spp. identification, due to their higher stability, high affinity, longer shelf lives, and lower costs of production than antibodies (Liu et al., 2020). In this context, Iqbal et al. (2015) developed a first electrochemical nanomaterial-based aptasensor using a screen-printed carbon electrode (SPCE) functionalized with AuNPs to detect C. parvum oocysts in fruit samples. Their design used 14 aptamer variants and thiolated DNA primers to immobilize the hybrid complex on SPCE. This aptasensor obtained a reasonable LOD and dynamic range (Table 1), facilitating food safety surveillance (Fig. 6) (Iqbal et al., 2015). However, reliance on AuNPs to enhance sensitivity increases fabrication cost and complexity, while the limited commercial availability of aptamers poses additional challenges. Addressing these challenges in the future can lead to the development of better practical aptamers for on-site detection of PPs.Fig. 6Schematic of an electrochemical aptasensor for C. parvum oocysts detection using screen-printed electrodes. The biosensor employs a thiol-modified aptamer-primer hybrid immobilized on the electrode surface. The binding of C. parvum oocysts disrupts electron transfer between [Fe (CN)₆]3−/4− redox probe and the electrode, detectable via voltammetry. This system leverages aptamer specificity to enable label-free oocyst identification, with signal inhibition correlating to target concentration. Adapted from (Iqbal et al., 2015), PLoS ONE 10(9): e0137455 (https://doi.org/10.1371/journal.pone.0137455). Licensed under CC BY 4.0 (https://creativecommons.org/licenses/by/4.0/).Fig. 6 Schematic of an electrochemical aptasensor for C. parvum oocysts detection using screen-printed electrodes. The biosensor employs a thiol-modified aptamer-primer hybrid immobilized on the electrode surface. The binding of C. parvum oocysts disrupts electron transfer between [Fe (CN)₆]3−/4− redox probe and the electrode, detectable via voltammetry. This system leverages aptamer specificity to enable label-free oocyst identification, with signal inhibition correlating to target concentration. Adapted from (Iqbal et al., 2015), PLoS ONE 10(9): e0137455 (https://doi.org/10.1371/journal.pone.0137455). Licensed under CC BY 4.0 (https://creativecommons.org/licenses/by/4.0/). Iqbal et al. (2019) expanded their work on spiked water samples by incorporating an AuNP-modified SPCE into an electrochemical aptasensor, where a biotinylated aptamer was bound to streptavidin-coated magnetic beads. Square wave voltammetry was used to monitor the increase in current, thereby improving the LOD to 50 oocysts. Aptamer-based biosensors are promising analytical tools for pathogen detection, including oocyst identification. However, there are certain challenges in their applications. The SELEX aptasensor selection method involves screening large oligonucleotide libraries through multiple rounds of selection and amplification. In addition, the variable and complex structure of oocysts can affect aptamer performance, highlighting the need to enhance SELEX efficiency to achieve high specificity for whole-cell or protozoan targets (Siwak et al., 2023). Magneto-electrochemical biosensor Simple electrochemical sensors are constrained by complex immobilization protocols, low repeatability, poor stability, and insufficient strategies for ultrasensitive detection. To address these limitations, magnetic nanoparticles (NPs), particularly iron oxide NPs exhibiting superparamagnetic properties and widely employed in magnetic separation (Chang et al., 2022; Wu et al., 2015), have been integrated, giving rise to magneto-electrochemical biosensors. These biosensors address the issues associated with simple electrochemical biosensors by efficiently isolating the target from complex matrices using external magnets, enabling electrode regeneration, and boosting detection limits due to integration with enzymes, DNA-based technologies, and nanomaterials. Their working principle includes the recognition phase, separation/preconcentration, signal generation, and quantifying the redox current, correlating with target concentration (Chang et al., 2022). For example, immunomagnetic separation (IMS) effectively isolates Cryptosporidium spp. and G. duodenalis oocysts/cysts from water samples ranging from 10 L (https://bit.ly/3Zk3D83). In this context, Nze et al. (2019) devised an electrochemical detection protocol for C. parvum in ground meat, utilizing immunomagnetic capture after hydrodynamic cavitation pretreatment, followed by cavitation of meat samples. Immunomagnetic capture of the pathogens was employed to eliminate non-target molecules, followed by signal amplification via polyG-coated secondary beads. The redox activity of the polyG label was subsequently monitored via SWV, enabling indirect quantification of C. parvum isolated from meat. This work streamlined sample preparation and detection to develop an integrated and fully automated platform to precisely recognize and quantify the multiple food- and waterborne pathogens (Nze et al., 2019). Developing high-quality nanoparticles, combining magneto-biosensors with microfluidics for high-throughput, POC detection, advancing signal amplification through the use of CRISPR/Cas system, and optimization with DNA walkers and catalytic hairpin assembly for rapid protein detection, through a multidisciplinary approach, will enhance the field's tractability (Chang et al., 2022). Other types of electrochemical biosensors Previously, different types of electrochemical biosensors have advanced Cryptosporidium detection. Nugen et al. (2009) developed a polymethyl methacrylate (PMMA) microfluidic electrochemical biosensor using magnetic beads-liposome complex and interdigitated ultramicroelectrode array (IDUA), achieving sensitivity down to one oocyst (Table 1), but faced cost and complexity limitations (Nugen et al., 2009). In contrast, the potentiometric biosensor developed by Laczka et al. (2013) utilized horseradish peroxidase (HRP)-labeled secondary antibodies, improving the LOD by 100–1000-fold compared to ELISA, without requiring expensive antibodies (Table 1) (Laczka et al., 2013). Alternatively, Houssin et al. (2010) demonstrated an EIS-based (label-free) biochip with an interdigitated microelectrode array to detect Cryptosporidium spp. in water samples (Table 1), offering real-time discrimination of viability via impedance shift between 10 kHz and 100 kHz. These innovations highlight trade-offs between sensitivity, cost, and practicality, with the amperometry system excelling in sensitivity, potentiometry in affordability, and EIS in label-free viability analysis (Houssin et al., 2010). Optical biosensors Fluorescence-based, SPR and microfluidic-integrated optical biosensor Optical biosensors integrate bioreceptors with optical transducers to enable the detection of output after interacting with analytes (Daramola et al., 2025). The signal intensity is proportional to the analyte concentration. The underlying mechanism is based on measuring the amount of absorbance, fluorescence, luminescence, and change in color and appearance or disappearance of color (Daramola et al., 2025). Optical biosensors provide appropriate equipment that uses SPR, absorption, fluorescence, Raman scattering, and reflectance to detect multiple kinds of analytes (Daramola et al., 2025). Fluorescence-based optical biosensors (FOBs) detect foodborne pathogens using antibodies to capture the target pathogen in a sample (Daramola et al., 2025). In this context, Kramer et al. (2007) devised a sandwich immunoassay for Cryptosporidium oocysts, combining anti-oocyst monoclonal antibodies for capture with cyanine 5 (Cy5)-labeled polyclonal antibodies for detection. Sensitivity was enhanced tenfold by specimen heating and by employing the polyclonal detection antibody (Kramer et al., 2007). To address fluorescence's short, excited-state lifetime, Gaft et al. (2015) introduced a luminescence-based mechanism enabling photon emission at any time (Gaft et al., 2015). Additionally, to improve the sensitivity of optical biosensors, SPR biosensors based on the refractive index were created (Zeng et al., 2021). SPR biosensors, leveraging refractive index changes, enhance optical biosensor sensitivity through label-free, real-time analysis with high specificity and throughput capacity, making it appropriate for food quality monitoring and ecological applications (Olaru et al., 2015; Zeng et al., 2021). In this regard, Kang et al. (2006) designed a flow-type SPR biosensor for rapid Cryptosporidium oocysts detection using mixed self-assembled monolayers (SAMs) (11-mercaptoundecanoic acid (11-MUA) and 3-mercaptopropanol (3-MPOH)). Nemati et al. (2023) noted that the biotin–streptavidin chemistry employed in this system enhances analyte accessibility to the sensor surface, improving the detection limit from 1 × 106 to ∼1 × 102 oocysts/mL (Kang et al., 2006) (Table 1). Microfluidic chips, as micro-total analysis systems, provide ideal platforms for integrating high-throughput optical biosensors that enable simultaneous detection of multiple pathogens in a single assay (Liao et al., 2019). Merging the versatility of optical sensing with the precision of microfluidics yields powerful tools for rapid, portable biosensing; for example, Angus et al. (2012a) demonstrated a field-deployable optical microfluidic biosensor capable of near-real-time, single-oocyst-level detection of C. parvum in field water samples. The system consists of a dual-inlet, single-outlet microfluidic design but requires labels (e.g., microbeads) and prior antigen removal from the oocyst to enable immunoagglutination. Despite the sensitivity (sub-single-oocyst detection with approximately 15 mL sample injection of the established sensing platform), the system necessitates labels like microbeads; on-site application is limited by these prerequisites (Angus et al., 2012a). When paired with filtration/concentration, this method can detect and identify ≤1 oocyst in large water volumes, matching or exceeding US-EPA 1623.1 efficiency. It reduces time and labor compared to staining microscopy with a one-minute detection assay (following a 4-min sonication step), and a linear range spanning five orders of magnitude. However, without filtration, the LOD was 1–10 oocysts mL−1, restricting its utility for rapid, near real-time field testing (Angus et al., 2012a). Raman spectroscopy is a light scattering technique that utilizes monochromatic light to excite molecules to higher energy states, leading to emission of radiation at different wavelengths, a phenomenon called Raman scattering. As the Raman signals are typically weak, coating the sensing surface with noble metals enhances the signal through Surface-Enhanced Raman Spectroscopy (SERRS). In this context, Rule and Vikesland (2009) developed a SERRS biosensor for the simultaneous detection of C. parvum and Giardia duodenalis (using immunogold labels-AuNPs linked to monoclonal antibodies tagged with rhodamine B isothiocyanate and malachite green isothiocyanate, respectively (Rule and Vikesland, 2009). These sensors demonstrate high sensitivity and specificity without antibody cross-reactivity, highlighting the potential of Raman-based multiplex pathogen detection. Despite these advances, SERRS biosensors face challenges in Cryptosporidium spp. detection, including difficulties in achieving reproducibility and quantitative results, with no studies reporting a precise detection limit (Luka et al., 2022). The time of acquisition is lengthy, up to 15–20 min per oocyst, and only samples with high concentration and low volume can be analyzed efficiently. Additionally, oocysts must be immobilized on the sensing surface, as their movement may interfere with measurements (Siwak et al., 2023). Colorimetric biosensor Colorimetric biosensors rely on identifying the color changes produced by biorecognition events. These color shifts can be measured optically in proportion to the analyte or assessed visually (Luka et al., 2015). Connelly et al. (2008) developed a microfluidic strip-based colorimetric biosensor capable of detecting a single Cryptosporidium oocyst in a 10 μL sample using a flow cytometer. However, the system encountered challenges from sample contaminants, microbes, and other limitations. Furthermore, Luka et al. (2021) developed a portable, colorimetric biosensor for Cryptosporidium RNA using oligonucleotide-functionalized AuNPs, enabling highly sensitive, specific, and label-free detection. Thiolated oligonucleotides complementary to adjacent Cryptosporidium RNA sequences were immobilized on AuNPs. Hybridization with target RNA caused nanoparticle aggregation, resulting in a noticeable color shift visible to the naked eye, while non-complementary RNA caused no color change. The test was built into a microfluidic chip housed in a 3D-printed device, eliminating the need for expensive lab equipment. A mobile camera records color variation for quantitative investigation. The linear range and the LOD for Cryptosporidium RNA are given in Table 1. This compact, affordable biosensor offers rapid, user-friendly pathogen monitoring in resource-limited settings, effectively identifying multiple Cryptosporidium spp. in water samples (Fig. 7) (Luka et al., 2021).Fig. 7Schematic of label-free Cryptosporidium RNA biosensor for contaminated water analysis. Sample collection proceeds with AuNPs functionalized with Cryptosporidium-specific oligonucleotides. Target RNA hybridization induces AuNPs' aggregation and a colorimetric shift (absent with non-complementary RNA), analyzed via smartphone imaging, enabling portable pathogen detection. Adapted from (Luka et al., 2021), Sci Rep 11:23192. (https://doi.org/10.1038/s41598-021-02580-w) Licensed under CC BY 4.0 (https://creativecommons.org/licenses/by/4.0/).Fig. 7 Schematic of label-free Cryptosporidium RNA biosensor for contaminated water analysis. Sample collection proceeds with AuNPs functionalized with Cryptosporidium-specific oligonucleotides. Target RNA hybridization induces AuNPs' aggregation and a colorimetric shift (absent with non-complementary RNA), analyzed via smartphone imaging, enabling portable pathogen detection. Adapted from (Luka et al., 2021), Sci Rep 11:23192. (https://doi.org/10.1038/s41598-021-02580-w) Licensed under CC BY 4.0 (https://creativecommons.org/licenses/by/4.0/). CRISPR/Cas12a-based fluorescent lateral flow strip (LFS) biosensor Innovations in the CRISPR/Cas12a-based biosensing have resulted in powerful, fast, and highly specific on-site detection tools for parasite identification. The basic principle of this technology involves amplification of the target sequence using recombinase polymerase amplification (RPA), without demanding thermal cycling, making it better suited for POC use. Design and preparation of crRNA, Cas12a/crRNA complex formation, target recognition, trans-cleavage of reporter molecules, followed by signal detection through fluorescence or LFS, constitute the primary working principle of such platforms for the detection of foodborne pathogens (Yu et al., 2021). This approach makes them suitable for resource-limited areas. The recent integration of the CRISPR/Cas12a system into a fluorescent lateral flow strip biosensor for on-site detection of C. parvum subtype family IId demonstrates the viability of CRISPR/Cas-based parasite detection. Utilizing the Cas12a/crRNA trans-cleavage mechanism, this system identifies as little as a single copy of the cloned C. parvum GP60 gene and 10 OPG following simplified sample preparation involving brief heat treatment with N-lauroylsarcosine sodium salt, eliminating complex commercial DNA extraction procedure or multi-step purification protocols. The assay exhibits no cross-reactivity with other C. parvum subtype families or common enteric protozoa. This subtype-specific detection is particularly valuable for food and water safety, as the IId subtype is the predominant zoonotic C. parvum strain for human-ruminant transmission. The method enables rapid source tracking during outbreaks, epidemiological surveillance of contaminated supplies, and public health interventions without requiring trained operators or specialized equipment (Yu et al., 2021). The combined RPA and CRISPR/Cas12a (ReCTC) detection assay involves the C. parvum chromosome 6, incorporating primer positions, target DNA sequence, crRNA binding site, and protospacer adjacent motif (PAM). It introduces RPA-amplified DNA into the system, where target recognition initiates ternary complex formation and enables visual quantification of analyte concentrations. The components include a fluorescent reporter, a quencher, and biotin, which enable fluorescence-based signal identification (Yu et al., 2021). Table 1 comprehensively presents different types of biosensors for detecting Cryptosporidium spp., underscoring the advancements regarding multiplexing, sensitivity, and portability. Recent innovations involve the 3D nano(gold)-structured microelectrode-based genosensor (Siavash Moakhar et al., 2023) to quantify lower concentrations of oocysts in water samples, hence, the development of label-free optical biosensors (Gu et al., 2019). Emerging technologies such as EIS microarrays (Luka et al., 2022) and aptamer-based conjugated magnetic-based platforms exhibit increased specificity and field adaptability. These platforms expand electrochemical, optical, and genosensor modalities, with trends toward simplified workflows (e.g., microfluidics, lyophilized reagents) and integration with nanomaterials, e.g., AuNPs, silver nanoparticles, to improve LOD and real global applicability for environmental and clinical monitoring. Types of biosensors aimed at detecting T. gondii in food and water samples Electrochemical biosensors Following the successful application of electrochemical biosensors for Cryptosporidium spp., they have increasingly been adapted for T. gondii. Their appeal lies in their straightforward fabrication, requirement for small sample volumes, and ability to produce measurable signals from molecular interactions on electrode surfaces (Nemati et al., 2023). DNA-based label-free electrochemical biosensors As a kind of excellent biomaterial, DNAs have been integrated to build various biosensors via interaction between biomolecules and DNAs, because of the advantages linked to DNA-based biosensors, such as rapid detection and operational comfort, in addition to high sensitivity and specificity (Hai et al., 2020). However, DNA-based biosensors mostly suffer from labeling requirements for nanomaterials or electroactive molecules on DNA as signal readout elements, which complicate operation and increase the cost of production. Label-free DNA-based biosensors appear as an excellent alternative in this regard; they are based on the intrinsic properties of DNA (aptamer binding, DNA hybridization, or catalytic activity) to transduce target recognition proportional to electrochemical signals. Nanomaterials and amplification strategies positively influence sensitivity, enabling ultra-low concentrations of targets (proteins, nucleic acids, and small molecules) (Hai et al., 2020). Gökce et al. (2016) developed a single-use electrochemical DNA biosensor for the voltammetric detection of sequence-specific DNA hybridization related to T. gondii. This label-free method detects DNA duplex formation by monitoring the guanine oxidation signal generated during DNA hybridization. The design of the biosensor consists of immobilizing a guanine-free, inosine-modified probe on the pencil graphite electrode (PGE) through the process of wet adsorption. The hybridization between the probe and target DNA was assessed using differential pulse voltammetry (DPV), with the guanine oxidation signal detected at +1.0 V on the PGE surface. Optimization studies revealed maximum DNA hybridization efficiency at a target concentration of 40 mg mL−1 and a hybridization time of over 50 min. Specificity tests demonstrated the biosensor's selectivity against non-complementary and mismatched DNA sequences. Under ideal conditions, the guanine oxidation signal indicating complete hybridization was identified at target concentrations shown in Table 2. The system efficiently recognized T. gondii DNA hybridization in PCR amplicons, indicating its potential in volumetric testing (Gökce et al., 2016).Table 2Different biosensors with transducers, chip types, LODs, and linear/dynamic ranges for the detection of T. gondii.AnalyteType of sensorTransducerType of chipLODLinear/dynamic rangeSourceReferenceT. gondiiImmunosensorElectrochemical biosensor (label-free/DPV)Pencil graphite electrode1.78 μg mL−10.5 to 25 μg mL−1DNA sample(Gökce et al., 2016)T. gondiiImmunosensorOpticalHuman recombinant galectin-3 and galectin-1 coupled to CM5 sensor chip (carboxymethylated dextran surface)Not reported0.2 to 1 μMGPIs(Debierre-Grockiego et al., 2010)T. gondiiImmunosensorOptical SPR biosensorNot reported (azurin, azurin-like protein (Laz) with SAG1)Not reported0.1 to 10 mMSAG1(Naguleswaran et al., 2008)Toxoplasma spp.ImmunosensorPiezoelectricInteraction of rTgMIC4 with glycoproteins utilized QCM-DaNot reportedNot reportedrTgMIC4(Santos et al., 2015)T. gondiiImmunosensorMicrofluidic optical biosensorMicrofluidic chip87 fg mL−11 pg mL−1 to 10 ng mL−1Lab-cultured oocysts(Chen et al., 2023)T. gondii, Cryptosporidium spp., and G. duodenalisGenosensorOpticalNot reported (CHAS)Not reported0.5 mg mL−1 to 20 μg mL−1DNA from contaminated fresh lettuce, parsley, and water samples(Reiling et al., 2021)T. gondiiGenosensorElectrochemical biosensor/DPVGraphite electrodes; AuNPs100 ng μL−1100 to 400 ng μL−1DNA samples(Alves et al., 2017)T. gondiiGenosensorMagnetic fluorescent nanoparticles (Fe3O4/CdTe)Solution-based assay (no physical chip used)8.339 nMNot reportedDNA oligonucleotides(He et al., 2015)T. gondiiGenosensorMagnetic-fluorescent CdTe @Ni quantum dots (mQDs)Not reported2.70 × 10−9 mol L−1Not reportedDNA(Xu et al., 2013)T. gondiiGenosensor (FRET-based)Fluorescence signal (CdTe/Fe₃O₄ quantum dots as donor and BHQ-2b as quencher)Not reported (magnetic nanoparticle-based system)Not reportedNot reportedCommercial DNA oligonucleotides (S1, S2, S3)(Liang et al., 2009)T. gondiiGenosensor (colorimetric)BTBNo chip (conventional tubes)0.014 T. gondii μL−1Not reportedab-cultured stool samples DNA(Zhang et al., 2022)T. gondiiColorimetric biosensorBTBNot specifiedAs low as 0.014 T. gondii μL−1Not reportedLab-prepared fecal sample DNA(Wang et al., 2024)QCM-Da: Quartz crystal microbalance with dissipation monitoring; BHQ-2b: Black hole quencher-2. Table 2Different biosensors with transducers, chip types, LODs, and linear/dynamic ranges for the detection of T. gondii.AnalyteType of sensorTransducerType of chipLODLinear/dynamic rangeSourceReferenceT. gondiiImmunosensorElectrochemical biosensor (label-free/DPV)Pencil graphite electrode1.78 μg mL−10.5 to 25 μg mL−1DNA sample(Gökce et al., 2016)T. gondiiImmunosensorOpticalHuman recombinant galectin-3 and galectin-1 coupled to CM5 sensor chip (carboxymethylated dextran surface)Not reported0.2 to 1 μMGPIs(Debierre-Grockiego et al., 2010)T. gondiiImmunosensorOptical SPR biosensorNot reported (azurin, azurin-like protein (Laz) with SAG1)Not reported0.1 to 10 mMSAG1(Naguleswaran et al., 2008)Toxoplasma spp.ImmunosensorPiezoelectricInteraction of rTgMIC4 with glycoproteins utilized QCM-DaNot reportedNot reportedrTgMIC4(Santos et al., 2015)T. gondiiImmunosensorMicrofluidic optical biosensorMicrofluidic chip87 fg mL−11 pg mL−1 to 10 ng mL−1Lab-cultured oocysts(Chen et al., 2023)T. gondii, Cryptosporidium spp., and G. duodenalisGenosensorOpticalNot reported (CHAS)Not reported0.5 mg mL−1 to 20 μg mL−1DNA from contaminated fresh lettuce, parsley, and water samples(Reiling et al., 2021)T. gondiiGenosensorElectrochemical biosensor/DPVGraphite electrodes; AuNPs100 ng μL−1100 to 400 ng μL−1DNA samples(Alves et al., 2017)T. gondiiGenosensorMagnetic fluorescent nanoparticles (Fe3O4/CdTe)Solution-based assay (no physical chip used)8.339 nMNot reportedDNA oligonucleotides(He et al., 2015)T. gondiiGenosensorMagnetic-fluorescent CdTe @Ni quantum dots (mQDs)Not reported2.70 × 10−9 mol L−1Not reportedDNA(Xu et al., 2013)T. gondiiGenosensor (FRET-based)Fluorescence signal (CdTe/Fe₃O₄ quantum dots as donor and BHQ-2b as quencher)Not reported (magnetic nanoparticle-based system)Not reportedNot reportedCommercial DNA oligonucleotides (S1, S2, S3)(Liang et al., 2009)T. gondiiGenosensor (colorimetric)BTBNo chip (conventional tubes)0.014 T. gondii μL−1Not reportedab-cultured stool samples DNA(Zhang et al., 2022)T. gondiiColorimetric biosensorBTBNot specifiedAs low as 0.014 T. gondii μL−1Not reportedLab-prepared fecal sample DNA(Wang et al., 2024)QCM-Da: Quartz crystal microbalance with dissipation monitoring; BHQ-2b: Black hole quencher-2. Different biosensors with transducers, chip types, LODs, and linear/dynamic ranges for the detection of T. gondii. QCM-Da: Quartz crystal microbalance with dissipation monitoring; BHQ-2b: Black hole quencher-2. Additionally, the integration of electrochemical techniques with nanomaterials (1 to 100 nm) like graphene, carbon, metallic nanotubes, organic polymers, silica nanoparticles, nanowires, and indium tin oxide (ITO) enhances biosensor performance and enables scalable production due to their high electrical conductivity (Singh et al., 2021). In this context, Alves et al. (2017) developed an electrochemical biosensor to detect T. gondii DNA, using a graphite carbon electrode modified with poly 3-hydroxybenzoic acid and functionalized with the ToxG1 probe. The sensor employed DPV to measure guanine oxidation signals triggered by hybridization with T. gondii genomic DNA, distinguishing complementary from non-complementary targets, with a detection limit of T. gondii DNA (Table 2). Hybridization between the ToxG1 probe and T. gondii DNA was further validated using optical assays with AuNPs, which exhibited a distinct shift in the probe's absorbance spectrum upon target binding (Alves et al., 2017). Optical biosensors T. gondii autophagy-related proteins and SPR biosensor Autophagy, controlled by autophagy-related proteins (Atg), is an important intracellular degradation mechanism in eukaryotes such as T. gondii that is required for cellular homeostasis and survival. This mechanism is based on ubiquitin-like conjugation systems, specifically Atg8-phosphatidylethanolamine (PE) and Atg5-Atg12 (Subauste, 2019). In a study by Chen et al. (2016), the conditional knockdown of T. gondii Atg3 (TgAtg3) genes disrupted TGAtg8 lipidation to PE, impairing parasite survival. The interaction between TgAtg8 and TgAtg3 is vital for T. gondii survival, positioning it as a potential target for parasite identification using SPR biosensing techniques. To investigate this interaction, the researchers immobilized pure TgAtg3 on a biosensor chip and activated it with 10 mM NiSO₄. SPR study with different doses of TgAtg8 indicated a significant binding affinity at 34.9 nM TgAtg8 (Chen et al., 2016). These findings provided a foundation for targeting the TgAtg8/TgAtg3 interaction in food surveillance systems. Using nanoparticles may improve the sensitivity and precision of SPR-based identification for this type of system. Colorimetric-biosensor-based detection of DNA hybridization As previously stated, microscopy requires a high level of knowledge and expertise and is less sensitive than colorimetric-biosensor-based detection of DNA. These types of biosensors detect the target DNA sequences through a visible color change, enabling rapid detection without the necessity of complex instruments. Their working mechanism involves DNA probes that hybridize with the DNA of interest, leading to variations in nanoparticle aggregation or enzymatic activity that generate a colorimetric signal corresponding to the hybridization event, leading to real-time detection (Syed et al., 2024; Xia et al., 2010). In this context, the study by Reiling et al. (2021) describes a cloth-based hybridization array system (CHAS) as an alternative to Sanger sequencing for confirming PCR-positive specimens. CHAS is a low-cost, fast, and efficient technique for the simultaneous detection of multiple protozoan parasite species through the colorimetric identification of PCR amplicons on a polyester cloth. PCR primers and CHAS hybridization probes were developed for the detection of Cryptosporidium spp., T. gondii, and G. duodenalis. When tested on artificially contaminated fresh produce (lettuce, parsley) and water samples (river and wastewater), this CHAS assay successfully detected Cryptosporidium spp., T. gondii, and G. duodenalis. This study demonstrated that the CHAS detection method provided a simple and cost-effective alternative to DNA sequencing for confirming PCR-positive results in laboratories that test food and water samples for parasites (Reiling et al., 2021). This assay may prove particularly beneficial in developing countries, where access to DNA sequencing facilities is often limited (Table 2). RPA-CRISPR/Cas12a-based LFS biosensor As discussed for Cryptosporidium spp., Lei et al. (2022) developed a portable, on-site detection system for T. gondii by integrating RPA with the CRISPR/Cas12a platform. This technique uses a glass microfiber filter to extract T. gondii DNA from low-concentration samples. Lyophilized RPA and Cas12a/crRNA reagents are preloaded into a single Eppendorf tube, enabling reactions to be conducted at 37 °C using a low-cost thermal controller. Targeting the T. gondii B1 gene, the system achieves a detection limit of 3.3 copies μL−1 with high specificity. Sample enrichment and lysis are followed by RPA and CRISPR/Cas12a detection, with fluorescence-based readout enabling portable, rapid (< 35 min), sensitive, and on-site analysis. The system, validated by real-time fluorescence intensity measurement (0–35 min), offers flexibility for field deployment, with results visualized using a fluorometer or LFS. This resilient and quick platform is ideal for on-site detection in remote areas (Lei et al., 2022), and shows promise for detecting T. gondii in environmental and food products. Table 2 highlights innovative biosensor-based approaches for T. gondii detection in food, water, and DNA-based samples. Debierre-Grockiego et al. (2010) designed an SPR biosensor targeting the interaction between glycosylphosphatidylinositols (GPIs) and gelatin-3, underscoring its role in the recognition of macrophages, which could inform diagnostic and therapeutic strategies. Naguleswaran et al. (2008) used SPR to demonstrate binding of an azurin-like protein to T. gondii surface antigen 1 (SAG1), thereby highlighting a novel inhibition mechanism for parasite invasion. Similarly, Santos et al. (2015) utilized a quartz crystal microbalance with dissipation monitoring (QCM) to elucidate the interaction between recombinant T. gondii micronemal protein 4 (rTgMIC4) and glycoproteins, thereby clarifying host-pathogen adhesion. Liang et al. (2009) and He et al. (2015) explored fluorescence energy transfer (FRET) using CdTe/Fe3O4 quantum dots and magnetic fluorescent particles, respectively, achieving sensitive T. gondii DNA identification with low LOD. Xu et al. (2013) devised CdTe@Ni quantum dots for magnetic-fluorescence DNA sensing, exhibiting a LOD of 2.70 × 10−9 mol L−1. Wang et al. (2024) introduced a bromothymol blue (BTB)-based colorimetric biosensor for the visual detection of T. gondii DNA in fecal samples, with minimal instrumentation. Zhang et al. (2022) developed a stem-loop primer-assisted isothermal amplification platform for semi-quantitative detection of T. gondii, synchronizing simplicity with visual readouts (Table 2). These studies collectively advance biosensor versatility, streamline workflows, and enhance field applications for parasitic detection. Transitioning biosensor applications: from clinical diagnosis to foodborne detection of PPs for early outbreak prevention Biosensors for Cryptosporidium spp. and T. gondii primarily utilize immunoassays and genosensors for clinical diagnosis. For Cryptosporidium spp., biosensors have been validated in lab-cultured oocysts (Thompson et al., 2020), stool (Laczka et al., 2013), and DNA samples (Ilkhani et al., 2019). For T. gondii, biosensors have been developed for serum (Jiang et al., 2013; Medawar-Aguilar et al., 2019; Salimi et al., 2023), stool (Zhang et al., 2022), and DNA samples (Alves et al., 2017; Gökce et al., 2016; Xu et al., 2013), supporting serological diagnosis as well as molecular detection of T. gondii. Echeverri et al. (2020) created a label-free electrochemical glycobiosensor detecting anti-GPI IgM and IgG antibodies in serum (LOD: 0.31 IU mL−1). Similarly, Takara et al. (2019) designed graphene oxide (GO)-polymer electrochemical sensors for serological detection of T. gondii specific IgG antibodies, whereas Medawar-Aguilar et al. (2019) introduced a microfluidic laser-induced fluorescence (LIF) immunosensor for the same purpose. Jiang et al. (2013) developed an Au-Fe₃O₄/graphene-based immunosensor for Tg-IgM, while Morovati et al. (2019) introduced a lateral flow biosensor targeting the dense granule antigen 7 (GRA7) for IgG detection (Table 2). In contrast to these assays, which detect host immunological responses. DNA-based biosensors suggest potential adaptability for detecting T. gondii directly in food matrices. Collectively, these methods show potential for detecting PPs in contaminated food and water, thereby strengthening public health surveillance of food- and waterborne transmission. Limitations and future perspectives Limitations Despite promising advances in biosensor technologies for detecting foodborne pathogens, significant limitations constrain their practical applications and require urgent attention to realize their full potential. Electrochemical biosensors While electrochemical sensors offer high sensitivity and low detection limits, their dependence on bulky electrochemical stations and need for warm-up period and polarization periods severely restrict their deployment for on-site and real-time applications (Dong et al., 2024). Moreover, bioreceptor stability remains a critical bottleneck due to the limited shelf life of antibodies and environmental instability; nucleic acid-based biosensors are constrained to DNA targets, and aptamers are sensitive to degradation by nucleases. Although integrating CRISPR/Cas with electrochemical DNA sensors has effectively improved both sensitivity and specificity (Wang et al., 2023), challenges persist in multiplex detection and seamless device integration, limiting their use in water and food matrices for multiple pathogen detection (Chen et al., 2022; Liu, 2025). Future research should focus on developing robust, multiplexed electrochemical platforms with stable bioreceptors and miniaturized, portable readout systems to enable their field applications. Optical biosensors Optical systems, including fluorescence- and SPR-based sensors, provide higher sensitivity but are often bulky, expensive, and sensitive to environmental factors such as temperature variations and motion artifacts. Their extensive calibration requirements and susceptibility to spectral interference undermine reliability in dynamic food processing settings. Fluorescent biosensors, despite their sensitivity, require high-priced instrumentation, limiting accessibility in resource-constrained settings. Colorimetric biosensors are simple but highly influenced by environmental conditions, reducing their robustness (Dong et al., 2024). Research should prioritize the emergence of cost-effective, calibration-free optical biosensors with enhanced environmental tolerance and integration with smartphone-based systems, which facilitates POC application (Han et al., 2021; Kakkar et al., 2023). Piezoelectric sensors Piezoelectric sensors show high thermal sensitivity and are better suited for dynamic monitoring; however, their application in detecting protozoa-specific indicators needs further exploration. This research gap highlights the need for targeted studies to adapt piezoelectric platforms for protozoan parasite detection, particularly when dealing with complex food samples (Feyziazar et al., 2022). Analytical versus operational sensitivity and sample preparation Despite low LODs (as summarized in Table 1), most were derived from spiked samples tested in microliter-scale volumes (5–50 μL) using purified oocysts in PBS or deionized water, rather than naturally contaminated food or water samples. Only limited studies validated complex matrices: Nze et al. (2019) used hydrodynamic cavitation to process ground beef samples; Yu et al. (2021) tested patient stool samples; and Poitras et al. (2009) demonstrated 20–64% signal suppression from environmental contaminants, effects ignored in most LOD calculations. This gap reflects an unresolved sample-to-answer bottleneck. Furthermore, achieving reported sensitivities requires substantial pre-concentration, e.g., Luka et al. (2022) reported 20 oocysts/5 μL, necessitating concentration of ∼200 L of water to 5 μL to meet regulatory levels) via filtration, IMS, or centrifugation steps are rarely integrated into current biosensor platforms. Viability differentiation Viability discrimination remains a critical limitation of conventional immunosensors and DNA-based sensors, which detect structural components persisting after cell death and thus cannot distinguish infectious from non-viable oocysts without additional processing (Brescia et al., 2009). However, emerging biosensor technologies are overcoming this constraint by targeting viability-specific biomarkers: EIS differentiates viable from heat-killed C. parvum via frequency-dependent impedance shifts reflecting membrane integrity (Dibao-Dina et al., 2015; Houssin et al., 2010); electrochemical detection of heat shock proteins (Hsp70) or nucleic acid sequence-based amplification (NASBA)-of viable-cell-specific rRNA enables metabolic activity assessment (Mahmudunnabi et al., 2024; Baeumner et al., 2001); and propidium monoazide (PMA) treatment combined with detection prevents signal generation from dead oocysts while preserving viable parasite signals (Brescia et al., 2009). Nevertheless, these biosensor-based viability correlates require rigorous calibration against gold-standard bioassays (mouse bioassay for T. gondii, cell culture for Cryptosporidium), as electrochemical signals may indicate membrane integrity without confirming infectivity, and most platforms remain at the proof-of-concept stage (Nze et al., 2019). General challenges in biosensor platforms A pervasive issue is the limited validation of biosensors in complex food matrices, where matrix effects can compromise sensor sensitivity and specificity. This limitation underscores the importance of comprehensive testing under practical conditions and the development of strategies to eliminate these interferences (Quintela et al., 2022; Zhang et al., 2025). Additionally, integrating multi-sensing modalities into a single platform to enable parallel multiplex detection remains challenging due to the need to balance reaction kinetics, sensor size, and signal transduction efficiency (Kulkarni et al., 2023; Ullah et al., 2024). The catalytic properties of nanomaterials such as gold‑palladium nanoparticles, copper(II)-reduced graphene oxide nanoparticles, AuNPs, iron metal-organic framework nanoparticles, silver nanocluster nanozymes, manganese dioxide nanoparticles, and manganese cobalt oxide offer promising avenues for straightforward colorimetric detection of diverse foodborne pathogens. However, operational stability, scalability, and cost effectiveness remain unresolved issues, particularly for large-scale adoption in resource-limited settings (Cambra-Pellejà et al., 2025; Kelly-Hope et al., 2018; Saldaña-Ahuactzi et al., 2025). The replacement of expensive gold electrodes with carbon-based materials enhances affordability, but requires long-term stability studies and the customer's training to ensure reliability (Cambra-Pellejà et al., 2025; Kelly-Hope et al., 2018). Collectively, these limitations highlight the gap between proof-of-concept biosensor designs and their reliable deployment in food and water safety monitoring. Future research directions and related gaps To advance technology for foodborne pathogen detection, additional studies should be carried out to (i) enhance sensor stability and robustness against environmental and matrix interferences, (ii) develop multiplex platforms capable of detecting multiple pathogens simultaneously and differentiating live from dead pathogens, (iii) integrate biosensor outputs with advanced algorithms and artificial intelligence to improve biomedical applications and predictive capabilities (Gattani et al., 2023; Luka et al., 2022), (iv) focus on cost reduction and miniaturization to facilitate deployment in resource-constrained environments and ensure equitable access, (v) design mobile-based biosensors utilizing smartphones, cameras, and optical biosensors specific for the detection of foodborne pathogens, enabling real-time, on-site detection, (vi) address the standardization and regulatory gaps, especially for PPs. Further studies should prioritize testing the sensor with other potential interferants and examining the sensor's abilities by establishing ISO-compliant, validated biosensor protocols (Ahmadi et al., 2020; Haleem et al., 2021; Syedmoradi et al., 2017). Regulatory and funding challenges The application of biosensor-based innovations into practical tools is further hindered by regulatory barriers and funding constraints (Bhandari et al., 2022; Casulli, 2021; Hotez et al., 2008). Increased awareness, interdisciplinary collaboration, and dedicated resource allocation are needed to scale up production and facilitate technology transfer. Critical challenges remain for widespread biosensor adoption in food safety surveillance, including a lack of standardized protocols for biosensor validation across diverse food and water matrices, insufficient data quality assurance frameworks, and limited interdisciplinary collaboration between sensor developers, food scientists, and regulatory bodies (Emma et al., 2024). Major gaps remain in tackling foodborne pathogen contamination due to the absence of standardized ISO methods for detecting pathogens such as T. gondii oocysts in fruits and vegetables. The WHO ASSURED criteria provide guidelines for developing efficient POC devices to identify major human diseases (Ahmadi et al., 2020; Syedmoradi et al., 2017), emphasizing affordability, sensitivity, specificity, and user-friendliness (Syedmoradi et al., 2017); however, research gaps exist regarding the detection of PPs in water and food matrices. Once regulatory, technical, and operational gaps are addressed, integration of biosensor-based detection into HACCP systems will follow as a logical step. Conclusions This review highlights biosensor-based technologies for the detection of zoonotic parasites, including Cryptosporidium spp. and T. gondii in complex matrices such as food and water, which may offer significant improvements in speed, precision, and portability. Emerging biosensors have remarkable potential for detecting minute concentrations of parasites, with some achieving a LOD as low as a single oocyst. Among these, electrochemical biosensors utilizing aptamers or antibodies as recognition elements have shown particularly promising results due to their higher sensitivity and affordability compared to spectroscopic and nucleic-based biosensors; however, their utilization at commercial levels has not yet been achieved. Innovative techniques such as CRISPR/Cas integration with smartphone-based readouts and the incorporation of nanomaterials further enhance sensitivity, enabling decentralized and real-time monitoring. Moreover, emerging electrochemical and optical biosensors detecting metabolic activity markers, heat shock proteins, or employing PMA-coupled detection, offer pathways to rapid viability screening, with NASBA-based methods achieving rapid detection. However, rigorous correlation of biosensor signals with infectivity assays is essential before these platforms can replace current gold standards in food safety surveillance. By bridging gaps in global food safety surveillance, biosensors hold great potential to mitigate the public health impact of foodborne parasites. Their integration into the HACCP system and POC diagnostics may revolutionize the food safety, ensuring safe food and water supplies and reducing the socioeconomic burden of cryptosporidiosis and toxoplasmosis. CRediT authorship contribution statement Munwar Ali: Writing – review & editing, Writing – original draft, Visualization, Validation, Software, Investigation, Formal analysis, Data curation, Conceptualization. Xiaohui Liang: Writing – review & editing, Visualization, Data curation. Ali Raza: Writing – review & editing, Writing – original draft, Visualization, Data curation. Chang Xu: Writing – review & editing, Writing – original draft, Formal analysis. Tingting Sun: Writing – review & editing, Writing – original draft, Methodology. Qing He: Writing – review & editing, Formal analysis. Zizye Zhu: Writing – review & editing, Visualization, Investigation. Kun Li: Writing – review & editing, Writing – original draft, Supervision, Project administration, Funding acquisition, Formal analysis. Lizeng Peng: Writing – review & editing, Visualization, Resources, Project administration, Funding acquisition, Conceptualization. Funding The study was partially supported by the 10.13039/501100001809National Natural Science Foundation of China (32102692), Innovation capability enhancement project of technology-based small and medium-sized enterprises of Shandong Province (2023TSGC0235), and Innovation capability enhancement project of technology-based small and medium-sized enterprises of Jinan City (Research on Key Technological Innovations for High-value Utilization of Rose rugosa cv. Plena through Probiotic Fermentation). Declaration of competing interest The authors declare no conflict of interest.