Intentional retrieval of a protruding ostial left main drug-eluting stent using a snare: a bail-out case report Authors: Mohamed Sarsari, Houda Bachri, Oualid Kerrouani, Jamila Zarzur, Mohamed Cherti, Abdelsalam Bensaaud, Ahmet Taha Sahin, John Kanakakis, Dimitrios Terentes-Printzios, Deepti Ranganathan Published: 2026 ABSTRACT AbstractBackgroundPercutaneous coronary intervention (PCI) of the ostial left main coronary artery (LMCA) is technically demanding and carries specific risks related to inaccurate stent positioning. Excessive stent protrusion into the aorta is a rare but potentially catastrophic complication.Case summaryWe report the case of a 60-year-old man with diabetes mellitus admitted for an acute coronary syndrome equivalent to ST-segment elevation myocardial infarction, related to a critical ostial LMCA stenosis. During emergent PCI, patient agitation led to excessive proximal protrusion (>8 mm) of a drug-eluting stent into the ascending aorta. Balloon optimization failed and resulted in stent deformation. Given the high risk of thrombosis, embolization, and aortic valve interference, intentional stent retrieval using a snare device was successfully performed, followed by optimal re-stenting of the LMCA ostium. The patient had an uneventful recovery.DiscussionIntentional extraction of a protruding coronary stent is exceptionally rare, particularly in the ostial LMCA. This case highlights the feasibility and safety of snare retrieval as a bail-out strategy when performed early, before endothelialization, and in carefully selected patients.Keywords: Left main coronary artery, Aorto-ostial lesion, Stent protrusion, Stent retrieval, Intravascular imaging, Case report Ostial left main PCI requires meticulous positioning to avoid geographic miss or excessive stent protrusion. Ostial left main PCI requires meticulous positioning to avoid geographic miss or excessive stent protrusion. Intravascular imaging (IVUS/OCT) plays a pivotal role in guiding stent placement and preventing complications in complex LMCA lesions. Intravascular imaging (IVUS/OCT) plays a pivotal role in guiding stent placement and preventing complications in complex LMCA lesions. Intentional stent retrieval using a snare may represent a safe bail-out option in selected cases of severe stent protrusion. Intentional stent retrieval using a snare may represent a safe bail-out option in selected cases of severe stent protrusion. Introduction Percutaneous coronary intervention of the left main coronary artery has emerged as a valid alternative to coronary artery bypass grafting in selected patients, particularly in isolated ostial or shaft lesions.1,2 However, aorto-ostial LMCA lesions remain among the most technically challenging scenarios in interventional cardiology. Precise stent positioning is crucial, as even minimal malposition may result in incomplete lesion coverage or excessive stent protrusion into the aorta. Stent protrusion is associated with an increased risk of stent thrombosis, restenosis, systemic embolization, and aortic valve injury. Management strategies are not standardized, and intentional stent extraction has only rarely been reported. Summary figure Case presentation A 64-year-old man with a history of hypertension, type 2 diabetes mellitus, and active smoking presented with acute chest pain suggestive of myocardial infarction. At admission, blood pressure was 140/88 mmHg, and heart rate was 90 bpm, without signs of heart failure. Electrocardiography demonstrated ST-segment elevation in lead aVR with diffuse ST-segment depression in inferior and lateral leads, suggesting critical LMCA ischaemia (Figure 1A). (A) Electrocardiogram showing ST-segment elevation in lead aVR, associated with ST-segment depression in the apicolateral and inferior leads. (B) Coronary angiography image demonstrating a severe ostial stenosis of the left main coronary artery (red arrow). The patient received guideline-recommended antithrombotic therapy consisting of: Aspirin 300 mg loading dose Aspirin 300 mg loading dose Clopidogrel 600 mg loading dose Clopidogrel 600 mg loading dose Unfractionated heparin 8000 IU intravenously Unfractionated heparin 8000 IU intravenously Transthoracic echocardiography showed preserved left ventricular systolic function with LVEF 55%. Given the clinical presentation consistent with a STEMI equivalent, the patient was transferred urgently to the catheterization laboratory. Coronary angiography Coronary angiography was performed via right radial access. The right coronary artery was angiographically normal. The left coronary system demonstrated a severe ostial stenosis of the left main coronary artery (Figure 1B). Percutaneous coronary intervention PCI was performed using a non-selective EBU 3.5 6F guiding catheter, as a JL guiding catheter was not available in our centre. Two 0.014″ SAMURAI guidewires were positioned: one in the left anterior descending artery and one in the left circumflex artery Lesion preparation was performed using a 4.0 × 15 mm non-compliant balloon. A 4.5 × 20 mm drug-eluting stent was then implanted from the LMCA toward the circumflex artery. This strategy was selected because the circumflex artery diameter was comparable to that of the left main trunk, minimizing vessel size mismatch that would have occurred with an LM-to-LAD strategy. Stent sizing was determined using quantitative coronary angiography software integrated in the General Electric angiography platform. Intravascular imaging (IVUS or OCT) would have been highly valuable in this complex ostial lesion; however, these imaging modalities were not available in our catheterization laboratory. Procedural complication During stent positioning, the patient developed severe agitation despite sedation with midazolam, requiring escalation to propofol sedation. Control angiography revealed displacement of the circumflex guidewire, requiring repositioning. After restoring wire position and repeating balloon advancement, angiographic control initially appeared satisfactory. However, after performing stent boost imaging, two unexpected findings were observed (Figure 2A): Excessive protrusion of the stent into the aorta; the protruding segment extends beyond 5 mm (arrow). (A) Coronary angiography image with StentViz. (B) Echocardiographic image (arrow). severe protrusion of the stent into the ascending aorta. severe protrusion of the stent into the ascending aorta. the guidewire crossing a lateral stent cell rather than the true stent lumen. the guidewire crossing a lateral stent cell rather than the true stent lumen. Despite this complication, coronary flow remained preserved. Because the protrusion was estimated to be greater than 8 mm, the risk of future thrombosis, restenosis, embolization, and aortic valve injury was considered significant. Staged management strategy Two options were considered: Accept the current angiographic result. Accept the current angiographic result. Attempt further optimization of the ostial stent position. Attempt further optimization of the ostial stent position. Given the potential long-term risks, we decided to attempt optimization. Because the patient was clinically stable and the procedure had already been prolonged, a staged reintervention was scheduled. Repeat echocardiography in the intensive care unit confirmed stent protrusion of approximately 8 mm into the ascending aorta without evidence of aortic regurgitation (Figure 2B). Cardiac surgeons were consulted prior to the reintervention and agreed with the percutaneous approach while remaining available for surgical backup if necessary. Reintervention Three possible strategies were considered. 1. Balloon optimization 1. Balloon optimization Balloon optimization was considered the initial strategy because it represented the safest and most conservative approach. This technique involves crossing the stent lumen with a guidewire and performing high-pressure balloon dilatation in order to optimize ostial stent expansion. Main challenges Difficulty in achieving stable intra-stent guidewire positioning. Difficulty in achieving stable intra-stent guidewire positioning. Risk of inadvertently crossing a lateral stent cell. Risk of inadvertently crossing a lateral stent cell. Guiding catheter instability in ostial lesions. Guiding catheter instability in ostial lesions. Potential complications Stent deformation. Stent deformation. Worsening protrusion. Worsening protrusion. Incomplete ostial coverage. Incomplete ostial coverage. Despite several attempts, intra-stent wiring remained unstable and resulted in compression of the proximal stent segment by the guiding catheter, making this strategy unsafe (Figure 3). Deformation of the proximal portion of the stent caused by the guide catheter. 2. Lateral stent crushing 2. Lateral stent crushing The second planned strategy was lateral crushing of the protruding stent segment. This technique consists of advancing a guidewire through a lateral stent cell into the distal vessel and performing sequential balloon inflations to crush the protruding segment, thereby creating a neo-ostium. Technical challenges Accurate guidewire passage through stent struts. Accurate guidewire passage through stent struts. Maintaining distal wire stability. Maintaining distal wire stability. Risk of incomplete crushing. Risk of incomplete crushing. Potential complications Systemic embolization of metallic fragments. Systemic embolization of metallic fragments. Aortic valve injury. Aortic valve injury. Distortion of the left main stent architecture. Distortion of the left main stent architecture. However, because the proximal stent had already been compressed by the guiding catheter during balloon optimization attempts, the structural deformation of the stent made this strategy unsafe and technically unfeasible. 3. Stent retrieval using a snare 3. Stent retrieval using a snare Given the failure of balloon optimization and the inability to safely perform stent crushing, we opted for intentional stent retrieval using a snare device. Technical challenges Capturing the stent without fragmenting it. Capturing the stent without fragmenting it. Maintaining coaxial traction. Maintaining coaxial traction. Avoiding vascular injury during extraction. Avoiding vascular injury during extraction. Potential complications Coronary dissection. Coronary dissection. Arterial perforation. Arterial perforation. Embolization or migration of the stent. Embolization or migration of the stent. Stent retrieval procedure The procedure was performed via 6F femoral access using an EBU 3.5 guiding catheter. A Medtronic snare kit was advanced into the ascending aorta, allowing successful capture of the protruding stent (Figure 4A). (A) Coronary angiography image showing stent capture using a snare device (Medtronic*). (B) Image obtained after stent explantation. The stent was carefully extracted using slow, coaxial traction, minimizing the risk of arterial injury or embolization (Figure 4B). The retrieval was completed without complications. Final PCI result After successful extraction, a new SYNERGY XD drug-eluting stent (4.0 × 20 mm) was implanted from the LMCA toward the LCx with approximately 2 mm ostial protrusion to ensure complete ostial coverage (Figure 5). Coronary angiography image after reimplantation of a new stent. Two inflations were performed at 12 atm for 30 s. Additional ostial optimization was performed using a TREK 4.0 × 12 mm balloon, with two inflations at 12 atm for 30 s. The final angiographic result demonstrated excellent stent expansion and optimal ostial positioning. The patient remained stable and was discharged after three days in intensive care without complications. Discussion Aorto-ostial LMCA lesions account for approximately 5%–8% of LMCA PCI indications and are associated with higher procedural complexity. Accurate identification of the true ostium is often challenging due to vessel foreshortening and overlap with the aortic wall. Intravascular imaging, particularly intravascular ultrasound (IVUS), has become a cornerstone in LMCA PCI.3,4 Contemporary management of left main coronary artery disease emphasizes meticulous procedural planning, systematic use of intravascular imaging, and individualized decision-making based on anatomical complexity and clinical presentation.5 IVUS allows precise assessment of lesion morphology, reference vessel diameter, and ostial localization and significantly reduces the risk of geographic miss and stent protrusion. Optical coherence tomography (OCT), while limited by blood clearance requirements, may also provide valuable information in selected cases. Current guidelines strongly recommend IVUS guidance for LMCA interventions. Excessive stent protrusion (>5 mm) into the aorta is uncommon but carries serious risks, including stent thrombosis, embolic stroke, and aortic valve damage. Several management strategies have been described. Balloon optimization using dedicated ostial techniques may be effective in mild protrusion but is often unfeasible in severe cases. Lateral stent crushing has been reported but exposes patients to embolic and mechanical complications. Intentional stent retrieval using a snare has been described mainly in cases of stent loss or migration, with very few reports involving the coronary circulation and exceptionally rare involvement of the ostial LMCA. Compared with previously published cases, our report is unique due to the anatomical location, the degree of protrusion, and the intentional nature of the retrieval as a planned bail-out strategy. To the best of our knowledge, intentional snare retrieval of a protruding drug-eluting stent from the ostial left main coronary artery has not been previously reported. Early intervention before endothelialization, careful patient selection, and operator expertise are critical prerequisites for the success of this approach. Conclusion Ostial LMCA PCI requires meticulous technique and precise stent positioning. Severe stent protrusion into the ascending aorta is a rare but potentially life-threatening complication. Management must be individualized and may include balloon optimization, lateral stent crushing, or intentional stent retrieval. This case illustrates that snare-assisted stent extraction can be successfully performed when other strategies fail, provided that the procedure is carried out carefully in experienced hands. Preventive measures remain essential and include accurate ostial identification, optimal angiographic projections, adequate patient sedation, and the use of intravascular imaging whenever available. Contributor Information Mohamed Sarsari, Faculty of Medicine and Pharmacy, Mohammed V University, Rabat 10000, Morocco; Cardiology B Department, Ibn Sina University Hospital, Rabat 10000, Morocco. Houda Bachri, Faculty of Medicine and Pharmacy, Mohammed V University, Rabat 10000, Morocco; Cardiology B Department, Ibn Sina University Hospital, Rabat 10000, Morocco. Oualid Kerrouani, Faculty of Medicine and Pharmacy, Mohammed V University, Rabat 10000, Morocco; Cardiology B Department, Ibn Sina University Hospital, Rabat 10000, Morocco. Jamila Zarzur, Faculty of Medicine and Pharmacy, Mohammed V University, Rabat 10000, Morocco; Cardiology B Department, Ibn Sina University Hospital, Rabat 10000, Morocco. Mohamed Cherti, Faculty of Medicine and Pharmacy, Mohammed V University, Rabat 10000, Morocco; Cardiology B Department, Ibn Sina University Hospital, Rabat 10000, Morocco. Lead author biography For image description, please refer to the figure legend and surrounding text. Dr Mohamed Sarsari is a cardiologist at the Department of Cardiology B, Ibn Sina University Hospital, Rabat, Morocco, and a faculty member at Mohammed V University. His clinical and research interests focus on complex coronary interventions, particularly left main coronary artery disease, acute coronary syndromes, and the use of intravascular imaging to optimize percutaneous coronary intervention outcomes. He is actively involved in interventional cardiology practice and has a growing academic interest in rare procedural complications and innovative bail-out strategies. Dr Sarsari aims to contribute to clinical research that improves procedural safety and decision-making in high-risk coronary interventions. Author contributions Mohamed Sarsari (Conceptualization, Data curation, Formal analysis, Investigation, Methodology, Project administration, Resources, Validation, Writing—original draft, Writing—review & editing [lead]), Houda Bachri (Data curation, Visualization [supporting]), Oualid Kerrouani (Data curation, Visualization [supporting]), Jamila Zarzur (Supervision [equal]), and Mohamed Cherti (Supervision [equal]) Consent: Written informed consent was obtained from the patient for the publication of this case report, including all clinical data and accompanying images. All authors have read and approved the final manuscript and agree with its submission. Funding The authors received no financial support for the research, authorship, and/or publication of this article. Data availability The data underlying this article are available within the article. Further data are available from the corresponding author upon reasonable request, while respecting patient confidentiality and institutional regulations. References Associated Data Data Availability Statement The data underlying this article are available within the article. Further data are available from the corresponding author upon reasonable request, while respecting patient confidentiality and institutional regulations.