Dynamical analysis of electroosmotic transport of bionic gyrotactic microorganisms with graphene oxide blood nanofluid through thermal ciliated channel Authors: Madiha Ajmal, Rashid Mehmood, Noreen Sher Akbar, Siddra Rana, Lemessa Asefa Eressa, Taseer Muhammad Published: 2026 ABSTRACT AbstractElectroosmotic bio-nanofluid transport is an important area of study in biomedical engineering especially in fields like targeted drug delivery and microfluidic devices. Nevertheless, the interactions of non-Newtonian Carreau fluid dynamics, cilia-based transport, electroosmosis, and gyrotactic microorganisms are not fully explored in the literature. The purpose of the current study is to investigate the electroosmotic flow of a graphene oxide based blood nanofluid with gyrotactic microorganisms within a thermal ciliated channel. The nonlinear equations governing are modeled by the Carreau fluid model and solved numerically by using Lobatto IIIa collocation method in computational software Maple. The findings demonstrate that the rise in Eckert number positively affects the temperature profile and the larger the nanoparticle volume fraction, the more favorable thermal distribution and the lower the microorganism density because of a better impact of Brownian motion. In addition, the higher the Peclet number, the greater the transport of microorganisms but the higher the thermophoresis and buoyancy parameters, the more the aggregation and stability of gyrotactic cells. These results indicate that electroosmotic forcing and ciliary movement can be efficiently used to regulate heat movement and distribution of microorganisms in bio-nanofluid systems. The work presents a detailed design of the optimal method to electroosmotic transport in the most advanced biomedical and microfluidic applications.Keywords: Heat transfer, Electroosmosis, Carreau nanofluid, Graphene oxide-blood, Microorganisms, Ciliary membrane Introduction Peristalsis is a condition caused by the constant compression and expansion of a distensible conduit used to carry fluids. It is a series of wave like muscular movement usually occur through digestive tract and also include movement of bile conduit, the transport of urine in humans, the mechanism of the gastrointestinal tract, ovum and embryo migration within tubes and blood flow in numerous small capillaries. These peristaltic waves that spread beside the cylinder walls in the gastrointestinal canal and some other tubular organs of the human physiologic tract instinctively travel longitudinally and circularly, propelling their contents. The peristaltic wave phenomenon finds extensive application in industries where direct contact with limits is forbidden, as it operates on the principle of symmetric contraction and relaxation. Examples include cell separation, the food, paper, ceramic, and porcelain industries, roller and finger pumps, and hurt-lung machines. Because peristalsis is useful in everyday life, researchers are beginning to favor it more and more. Since Latham [1] conducted the initial studies, an excessive agreement of theoretical and practical research has been conducted on peristalsis. Research by Fung [2] examined an idealized two-dimensional approximation of two-dimensional channel with constant width and unlimited length that is traversed by a sinusoidal wave. It is necessary to ascertain how a viscous fluid inside the channel is moving. Boxerbaum et al. [3] reported on the first finished prototypes of a new sort of robot that moves like an earthworm using a continuous wave of peristalsis. The endoscopic and sliding effects on particle fluid dispersion blood flow caused by peristaltic waves passing through non-uniform annuli are discussed by Bhatti et al. [4]. The momentum equation for the fluid phase and the particulate phase are modeled using an approximation of minimal Reynolds and long wavelength. The peristaltic flow of Prandtl-Eyring fluid through a circular cross-section conduit is examined by Shahzad et al. [5] under the long wavelength approach assumptions, to solve the mathematical model they used algebraic solutions and the perturbation technique in combination. Srinivas and Muthuraj [6] described a mixed convective heat and mass transmission peristaltic movement over a erect absorbent plane in occurrence of a chemical reaction, the asymmetry of the channel is created by selecting a different amplitude and segment for peristaltic wave train on the walls. For the purpose of developing a peristaltic endoscope, the electro magneto hydrodynamic peristaltic stream of blood past an annulus tube between two concentric circular pipes has been studied by Yadav and Roshan [7]. Peristaltic flow of Carreau fluid through a permeable media in a rectangular duct was investigated by Ellahi et al. [8] their research was probably directed toward comprehending how viscosity changes with shear rate—one of the rheological characteristics of Carreau fluids—affect flow patterns in permeable surface. Munir et al. [9] discussed that the concentration occurs during the peristaltic transfer of viscous fluid in an asymmetric channel. There are convective boundary conditions on the channel walls with consideration of both hydrodynamic and magneto hydrodynamic (MHD) fluid situations [10–13]. The thin, hair-like antennae known as cilia are present on the surface of every vertebrate cells. These are essential characteristics and can be one or several. Cilia are necessary for mobility. They also take part in mechanoreceptor function. Ciliates are organisms that have cilia on them. They move and feed using their cilia. The force required to move foreign objects from the respiratory system into the mouth, where they can be ingested or expectorated, is provided by specialized organelles called cilia. They are extremely preserved organs that are present on the surface of cells in a wide variety of eukaryotic species. Although cilia are also referred to as flagella, the name cilium is frequently used over flagella to avoid ambiguity with bacterium flagella, which differ physiologically from eukaryotic flagella. The cilia’s consistent movement is what allows them to transfer water in relation to the cell. This procedure may trigger the cell to pass across the fluid or transport fluid and its components on the outer layer of the cell, as is common in numerous organisms with just one cell. Nearly all cells in the body include cilia, which are responsible for moving fluids through the cell and rotating the cell. The body’s healthy functioning is maintained by these mechanisms. These microscopic organelles, often referred to as cilia. They are important in the medical sciences in addition to aiding in the removal of germs from the tissue surfaces of the lungs. A peristaltic wave produced by cilia beating can aid in moving fluid forward. Ciliary motion has wide applications in medicines including human biological systems like respiratory system, urinary system, reproductive system and gut system. The importance and complexity of this process can be understood by some natural and technical procedures. Like ova or egg transportation in reproduction process, pulmonary phlegm clearing, and microfluidic systems using artificial cilia-like structures. In recent years of research due to high demand of the phenomenon of ciliary motion, it has attracted a lot of attention from researchers in recent years. Kramer et al. [14] demonstrated the motility of the cilia in the cerebellum, Kupffer’s vesicle, and zebrafish larval kidney, indicating that fluid flow is a characteristic shared by all three of these tissues. Hydrocephalus, left–right asymmetry problems, and the creation of perinephric cysts were the outcomes of disruptions in the structure or motility of the cilia. Using OCT-based particle tracking velocimetry Jonas et al. [15] demonstrated the quantitative, two-dimensional, two-component characterization of the flow velocity field. More thorough study in respiratory medicine and ciliary biology were made possible by quantitative imaging and phenotyping of cilia-driven fluid flow using optical coherence tomography (OCT). Akbar et al. [16] Akbar conducted a theoretical investigation on the ciliary-induced transportation using metachronal transmission of waves in hydro magnetic flow of copper–water Nano fluids via a low Reynolds number parallel plate channel. Siddiqui et al. [17] focused on the magneto hydrodynamic flow of an incompressible Newtonian fluid in an aperture that is generated by cilia. The current work also shows that applying a stronger magnetic field can lessen the amount of Newtonian fluid that is trapped in a ciliated channel. Their analysis were used and contrasted with the recorded spermatic fluid flow rate in the male reproductive tract’s ductus efferent. Hanasoge et al. [18] demonstrated that the variation in electromagnetic cilium’s size regulates the beating motion’s frequency. By utilizing this property, one can create metachronal waves inside a ciliary array and investigate how different operation parameters affect the wave motion. It was shown that the magnetic and elastic properties of the filaments controlled the metachronal movement in their artificial system, in contrast to natural cilia where metachronal movement is caused by fluid interaction. Their method makes it simple to incorporate metachronal magnetic cilia for improved fluid and particle manipulation in lab-on-a-chip devices. Farooq [19] studies how cilia propel themselves when epididymis material passes via the conduit afferents. The mathematical equations are linearized by using the long wavelength and high viscous flow assumptions. Examining the circulation and entrapment processes brought on by the ciliary metachronism inside the tube receives particular focus. Khaderi et al. [20] presented the fundamental findings of a thorough numerical study of creating fluid flow with artificial cilia driven by magnetism. The two strokes that make up the cilia’s operating process are the most efficient and recuperation. The goal of lab-on-a-chip (LOC) innovation is to analyze biological specimens on a tiny chip, replacing the traditional clinical lab at a hospital. The flow is driven by a powerful pressure difference created by the localized high and low pressure fields caused by the cilia’s displacement. Furthermore, [21–26] indicate that there are more studies examining related subjects in the literature, demonstrating the depth of interest in this field and the continuous attempts to understand the complexities of ciliary motility and its consequences. A vast amount of theoretical and experimental research has been conducted based on the intriguing discovery made by Ferdinand Friedrich Reuss [27] more than 200 years ago, which involved the movement of water through a clay connection when an external electric field was applied. The discovery’s most significant result was the capacity to create water flow using only an external electric field and no mechanical components. The interaction of an external electric field with a charged surface that is counterbalanced by a fluid layer is the fundamental mechanism behind electrokinetic transportation. Electroosmotic flow constitutes one of the most renowned types of electrokinetic transfer. Electroosmotic flow has been utilized and researched considerably because it can be used as a pump to move fluid over an electrically conductive environment. It is well known that an electric double layer forms close to an electrified solidifying layer when it comes into contact with a fluid media. With a high proportion of antagonists over coins to balance the exterior charge, the electric double layer is typically seen in a relatively thin zone near the charged surface. Consequently, general fluid flow in the direction of choice will occur under an applied electric field and is known as electroosmosis. The fact that the volumetric flow rate of Electroosmotic flow can be compared to pressure-driven flow in micro- and nanoscale media is one of its key characteristics. Consequently, it is critical to investigate Electroosmotic flow in micro- and nanochannels and porous media in order to comprehend its effects on the movement of charged species or water. Electroosmotic pumping has many advantages over conventional pressure-driven pumping, including being simpler to manufacture and regulate, having no rotating components, minimizing data variation, and producing little to no noise. In recent years, there has been a lot of interest in the application of electro kinetic applications for pumping fluid models of nano volumes in BioMEMS and Lab-on-a-Chip micro devices [28–33]. Electro-fluid propellers in space transportation, polyurethane the infusion structures, electrostatic cell structures, organisms fuel cells, biochip manufacturing, the electricity generated by fossil fuels procedure. Micro physiological nuclear power plants, and pump layouts for microfluidic analytical chromatography, isoelectric peptide concentrating, micro channels, electrokinetic flow through an elongated tubes, cartilage at the joint transport of contaminants, and electrodes array construction are some of the prospective nanotechnology uses for electro-osmotic movement [34–40]. Electroosmotic flows may be created artificially in a number of electrical and chemical methods, as well as occurring naturally in things like blood flows. Tripathi et al. [41] examined the electro-kinetic impact on the irregular blood flow during peristalsis in spherical finite-length arteries, a mathematical model is created. They provided an analysis contrasting the travel time of train waves and single waves in relation to the external electric field and EDL thickness. Their research has implications for synthetic electro-osmotic pumps, electro hydrodynamic treatment, and electrophysiology in hematology. The motion of two-fluid electro-osmotic peristaltic flow within a cylindrical vessel is examined by Ali et al. [42], They used electro-kinetic slip velocity and the Ellis model parameters for detailed investigation of the pumping characteristics, trapping, and reflux events. Their findings could have implications for controlling peristaltic pumping to ensure the smooth functioning of several industrial and biomedical equipment. Using microchannel research, Tripathi et al. [43] examined quantitatively the unsteady viscid fluid flow caused by both the influence of electro-osmosis and peristalsis. The fluid bolus movement over the conduit dimension is modeled by a total number of waves traveling in the microchannel. To calculate a possible component with assumptions of a smaller Reynolds number as well as long wavelength, Debye–Huckel linearity is utilized. Beg et al. [44] explored in a microchannel, electro kinetic peristaltic multi-layered transportation of a radial electrical field with the usage of three distinct concentrations that have been generated for each of the three fluid portions: the main, intermediary, and outermost layers. Microvascular non-Newtonian blood flow is analyzed analytically by Tripathi et al. [45], taking the electro-osmosis phenomenon into account. Blood is seen as an aqueous ionic solution with Bingham rheology. The system is subjected to an externally applied static axial electrical field. In the microvascular regime, the electrical double layer is taken into account by applying the Poisson-Boltzmann equation for electrical potential distribution. The electro osmotically enhanced peristaltic transporting of an electrically conductive water ion nanofluid via an inclined asymmetrical conduit is investigated by Khan et al. [46] computationally via an illustration model. Among their conclusions are that in the event of an opposing electric field, the streamline bolus crosses the channel’s midline for positive parameter values. Akram et al. [47] studied the peristaltic-ciliary circulation of propylene glycol and water that is electroosmotically activated to deliver titania nano sized particles. The thorough examination of the data produced by the computational solution of the problem under consideration shows that heat is quickly removed from the system and their effectiveness is increased as a result of the nanoparticles’ dispersion. A new avenue in the medical field has been made possible by continuing investigations on the electro osmotically simulated bloodstream interspersed with gyrotactic microorganisms in the blood vessel system. Blood is a biological fluid that carries many substances such as nutrition, hormonal substances, oxygen and carbon dioxide, and residues from metabolic. Body temperature, osmotic pressure, acidity, and cell-level biochemistry are all regulated by blood. gyrotactic microorganisms doped vascular circulation models and simulations are highly pertinent to cardiovascular phenomena and sickness. Using arteries that have both blockage and aneurysm, Abdel Salam et al. [48] analyzed the physical characteristics of electro-magneto-hydrodynamics of the arterial blood flow for a hybrid fractional second-grade nanofluid in the context of electroosmotic pressures. Nadeem et al. [49] studied heat and mass transfer in a complicated, curved microchannel that was controlled by electroosmosis in order to study microscopic blood flow in capillaries. The implications of chemical reactions and joule heating are explored. Das et al. [50] described the examination of the peristaltic migration of blood embedded in synthetic nanoparticles via an endoscopic disc with stretchy walls when blood coagulation is present and electromagnetic forces (EMF) are present. Ion-slip currents and Hall currents are taken into account in tandem. The hemodynamic properties of the blood circulatory system imbued with ternary composite nanoparticles by means of a diverging/converging ciliary micro-vessel are evaluated by Ali et al. [51] using a mathematical simulation that considers the combined influence of buoyancy, viscoelastic, electro-osmotic, and Lorentz forces. Some related studies are [52–57]. Although much has been done on the study of electroosmotic and nanofluid flows, there has been little research on the effects of non-Newtonian rheology, cilia-mediated transport and gyrotactic microorganisms. The novelty of the paper is that it combines the electroosmotic transport phenomena, and the dynamics of bionic gyrotactic microorganisms suspended in a graphene oxide-based blood nanofluid, and it is modeled based on the Carreau fluid framework to capture the shear-thinning non-Newtonian behavior of blood. The combined analysis allows a more in-depth insight into the interplay between fluid rheology, electric forcing, heat and mass transfer, and the distribution of microorganisms, which has not been discussed in previous studies collectively. Thus, the current study contributes to existing literature by providing a cohesive model of examining the process of electro-bioconvective nanofluid transport with practical uses in biomedical and microfluidic practices.This work is the first to include the influence of thermal ciliated channel walls, which cause propulsion that affects the flow stability and distribution of microorganisms making the study more realistic and simulating real physiological conditions. The improved thermal and electrical characteristics endowed by graphene oxide nanoparticles are explicitly studied alongside the intricate interactions among the electroosmosis, cilia movement, and the gyrotactics of microorganisms. This holistic methodology proceeds the knowledge of microfluidic transport processes in bio-nanofluids, which could find applications in controlled delivery of drugs, microscale biosensing devices, and environmental biomedical devices where high accuracy in controlling microorganism behavior and heat transfer is essential. Mathematical modeling Consider the situation of blood-based graphene oxide nanofluid flowing over a ciliate conduit with motile gyrotactic bacteria. Cartesian coordinates are rummage-sale to formulate the mathematical model. Moreover, the subsequent conditions are used to conduct the study: The Carreau model expects the non-Newtonian possessions of blood. The Carreau model expects the non-Newtonian possessions of blood. graphene oxide nanoparticles in an aqueous resolution with a usual diameter of 10 nm make up the nanofluid. graphene oxide nanoparticles in an aqueous resolution with a usual diameter of 10 nm make up the nanofluid. For nanofluid flow, the improved Buongiorno model is used. For nanofluid flow, the improved Buongiorno model is used. The electroosmosis progression also affects fluid dynamic forces, carried on by an axial electrical field . The electroosmosis progression also affects fluid dynamic forces, carried on by an axial electrical field . The bioconvection equipment examines the fluid’s flexibility in relation to motile bacteria. The bioconvection equipment examines the fluid’s flexibility in relation to motile bacteria. The electroosmotic and microfluidic transport systems are characterized by low Reynolds number flow (Re ≪ 1). As a result, the flow is laminar and the viscous and electrokinetic forces outweigh the inertial forces. The electroosmotic and microfluidic transport systems are characterized by low Reynolds number flow (Re ≪ 1). As a result, the flow is laminar and the viscous and electrokinetic forces outweigh the inertial forces. In microfluidic modeling, it is also typical to assume that the channel’s walls are impermeable and hard. Since the focus of this research is fluid transport, the solid–fluid thermal interaction is not taken into account. In microfluidic modeling, it is also typical to assume that the channel’s walls are impermeable and hard. Since the focus of this research is fluid transport, the solid–fluid thermal interaction is not taken into account. Using the above mentioned assumptions, the basic equations of governed fluid problem become. The sinusoidal wave travels down the wall of the conduit , where In elliptical tracks, cilia are mathematically set up to function as The following vertical and horizontal velocities are also necessary for the cilia to be active with breadth , wavelength (), constant velocity , is the channel’s half-width at arrival, and is the channel’s length-dependent constant. Using the transformation equations defined in Eq. (6), the governing equations for the governed fluid problem become as follows (refer to Ref. [37, 42, 58]): The stress tensor component of Careau fluid model are provided by , , Here an extra stress tensor , zero shear-rate viscosity , infinite shear stress viscosity , time constant , second invariant of strain-rate tensor and power law index in dimensionless form. For The following is the explanation of the electroosmotic forces equation [37] The calibrated Boltzmann standard distribution for minimal zeta potential can be used to accurately specify the local ionic dispersal of ionic species without obscuring the flow problem since the produced power potential for the majority of the solution containing electrolytes erupts within the limit of lower than or equal to 25 mV. Using linearized Poisson-Boltzmann Byusing approximation of linearized Poisson-Boltzmann [37]: By utilizing [59] i.e. (Debye-Hückel approximation) With defined BCs when and is the. Presenting stream function like this The following are the quantities used to convert the problem under deliberation into dimensionless form: Hence final version of system of equations become Corresponding boundary conditions are. Numerical procedure The two-point boundary value problem is given by the governing non-linear differential equations, Eqs. 23, 24, 25, 26, 27 and 28 and boundary conditions, Eqs. 29 and 30 . The reason for utilizing a numerical approach is due to the strong nonlinearity and interconnection of the system, whereby it is not possible to obtain analytical solutions. To convert the system of higher-order differential equations into a system of first-order differential equations, the appropriate auxiliary variables are introduced. The equations are then solved numerically using MAPLE’s built-in solver. The solver utilizes the three-stage Lobatto III a collocation method for solving nonlinear boundary value problems with high accuracy and stability. The initial guess is supplied with a solution that satisfies the boundary conditions, and the computational domain has been discretized into a finite mesh. The solver uses an iterative solution refinement process until the required convergence criteria are met. Tolerance levels are kept small to ensure result accuracy. The complete solution procedure is mentioned below in flow chart: Flow chart of Solution Procedure To compute the volumetric flow rate, the velocity profiles (of both the nanofluid and the particle phases) are integrated across the height of the channel. where Calculating the non-dimensional rise in pressure over one wave length is given as follows Numerically determined wall friction using the shear stress distribution is the basis of our numerical method for obtaining velocity, temperature, nanoparticle concentration, and microorganism densities due to the effects of Electro-osmotic forces, ciliary motion, and non-Newtonian behavior and is thus appropriate for performing a parametric analysis regarding the governing physical parameters. Convergence and stability To obtain a converged solution to the problem, the bvp4c solver in MAPLE is used for solving the system through collocation and following the three-stage Lobatto IIIa method with a well-established fourth-order convergence property for non-linear BVPs. The Collocation process provides an estimated initial guess of all dependent variables; this estimated initial guess is then iteratively improved through multiple uses of the bvp4c solver until convergence is obtained. Convergence is defined by a small enough value for the relative tolerance (typically , resulting in no discernable differences between solutions after consecutive iterations of our solution profile occur. The solver automatically performs mesh refinement using automatic step size control. As a result of a grid independence test that increased the number of grid points, numerical convergence was affirmed when the mesh density reached a value at which no further change was seen in results. The implicit nature of the Lobatto IIIa scheme guarantees stability for both stiff and nonlinear systems. The stability of the calculation continues without issue, even when velocity, temperature, nanoparticle concentration, and concentration of microorganisms are strongly coupled via their governing equations. Results and discussions This study examines the transfer of gyrotactic microorganisms nanofluid flow characteristics in a tube using a Carreau fluid and graphene-blood nanofluid, resulting in a metachronal rhythm caused by ciliary mechanisms. Thermophysical properties are presented in Table 1. The relevant equations for flow dynamics are simplified by using low Reynolds and long wavelength assumptions. The solution is implemented in MAPLE using a numerical procedure described in above section, and the results are illustrated with pictorials. Table 1Thermophysical propertiesNanoparticles characteristicsAppearanceViscosity ()Density ()Thermal expansionSpecific heat capacityThermal conductivity() Thermophysical properties Thermal expansion Specific heat capacity Thermal conductivity () Figures 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35 and 36 highlights the impact of important physical parameters such ‘’ the Eckert number, ‘’ the buoyancy ratio parameter, ‘’ the power law index number, the Brownian parameter ‘’, thermophoretic parameter ‘’, ‘’ the Weissenberg number and ϕ the volumetric fraction on temperature, concentration and microorganism density profiles, pressure rise and gradient, streamlines and temperature contours. Influence of Eckert number on temperature profile Influence of buoyancy ratio parameter on temperature profile Influence of thermophoresis parameter on temperature profile Influence of Brownian motion parameter on temperature profile Influence of Weissenberg number on temperature profile Influence of Power index number on temperature profile Influence of volumetric fraction on temperature profile Influence of volumetric fraction on concentration profile Influence of Eckert number on concentration profile Influence of buoyancy ratio parameter on concentration profile Influence of Weissenberg number on concentration profile Influence of power index number on concentration profile Influence of thermophoresis parameter on concentration profile Influence of Brownian motion parameter on concentration profile Influence of Eckert number on motile density profile Influence of buoyancy ratio parameter on motile density profile Influence of thermophoresis parameter on motile density profile Influence of Brownian motion parameter on motile density profile Influence of Weissenberg number on motile density profile Influence of power index number on motile density profile Influence of volumetric fraction on motile density profile Influence of Peclet number on motile density profile Influence of Grash off number Gr on pressure gradient dp/dx Influence of power index number n on pressure gradient dp/dx Influence of volumetric fraction on pressure gradient Influence of chemical reaction parameter ϭ on pressure gradient Influence of Weissenberg number on pressure gradient Influence of Grashoff number on pressure rise Influence of power index number on pressure rise Influence of volumetric fraction ϕ on on pressure rise Influence of Weissenberg number on pressure rise Streamlines contours for flow rate Temperature contours for flow rate Streamlines contours for Nanoparticle volumetric fraction Temperature contours for Nanoparticle volumetric fraction The quantitative data of the temperature profile of the fluid system as shown in Figs. 2, 3, 4, 5, 6, 7 and8 offer great insights into the physical processes involved behind the dynamics of heat transfer and fluid flow in the presence of bionic gyrotactic microorganisms and graphene oxide blood nanofluid, in a thermal ciliated channel (Fig 1). Geometrical Structure of the problem The analysis of the influence of the Eckert number on temperature profiles is a critical aspect in comprehending the phenomena of fluid dynamics and heat transfer processes, hence Fig. 2 shows how Eckert number (Ec) influences the temperature distribution. The Eckert number is a physical measure of the ratio of the difference in kinetic energy and enthalpy between the flow and is directly proportional to the effects of viscous dissipation. The greater the the more the mechanical energy (generated by fluid motion) is converted to thermal energy leading to high fluid temperatures. This is especially applicable in micro and nanoscale flows whereby we cannot afford to ignore the issue of viscous heating. The increased viscous dissipation elevates the internal energy of the fluid and hence elevates the local temperature and affects the thermal boundary layer thickness. Impact of number on temperature profiles shows that magnitude of temperature increases with rise in Eckert number, highlighting the role of viscous dissipation in the thermal behavior of the system. As the Eckert number increases, the transformation of kinetic energy into internal energy becomes more evident, resulting in a more substantial increase in temperature. In the study of heat transfer and fluid dynamics, the buoyancy ratio parameter is frequently a significant factor in natural convection processes. Figure 3 indicates that the buoyancy ratio parameter is central to the process of convection that is driven by buoyancy. The higher the , the higher the density gradient between the fluid and the surrounding medium that increases the buoyant forces on the fluid. This enhanced buoyancy increases the rate of fluid movement upwards, increasing convective heat transfer leading to an increase in temperature values. This act is in accordance with the classical natural convection theory where the buoyancy forces facilitate mixing of the fluid and heat transfer, thus, changing the temperature field. So, Fig. 3 designates that by improving the buoyancy ratio parameter there is a rise in temperature graph. This is likely because as increases, the density difference between the fluid and the surrounding environment also increases. This greater density difference results in a stronger buoyant force, causing the fluid to rise more quickly and leading to a higher temperature. This is logical, as a more buoyant fluid will have a greater propensity to rise and displace the surrounding fluid, resulting in a temperature rise. Figure 4 deals with how the thermophoresis parameter affects the temperature profile. Thermophoresis is defined as the movement of particles in regions of a higher temperature to a lower temperature and this is much applicable in the context of nanofluid flows. With an increase in , nanoparticles acquire an increased thermophoretic force, and a redistribution of the particles takes place influencing the local thermal conductivity and heat capacity. Local heating can be induced with this movement, increasing the overall temperature profile by modifying the distribution of thermal energy in the fluid. It worth to mention here with rise in the value of temperature is lifted. Understanding the temperature distribution in fluid flows is crucial, particularly in systems that involve nanoparticles or other small particles. This parameter plays a key role in this understanding. Particles are moved from hotter to colder locations during the thermophoresis process. The fluid's total temperature may rise as a result of the localized heating effects produced by this movement. The heat transfer characteristics in nanofluids can be significantly affected by the presence of nanoparticles. When the values are higher, it enhances the thermophoretic movement of these particles, resulting in increased temperatures. The trends in Figs. 5 and 6 show that as the Brownian motion parameter and the Weiss number are increased the temperature drops. Brownian parameter is used to measure the random movement of nanoparticles, which improves mixing and homogenizes temperature gradients. This enhanced dispersion aids better heat transfer, which avoids local heat spikes thus lowering peak temperatures. Weissenberg number is a measure of the elastic influences in the fluid; the greater the values of , the greater the viscoelastic behaviour. This elasticity has the potential to change the flow structure in terms of storage and release of elastic energy which facilitates a greater amount of energy dissipation and heat transfer, hence reducing the temperature. Hence Figs. 5 and 6 shown that increasing the Brownian parameter and Weissenberg number decreases the temperature for both blood and graphene blood oxide. This implies that more Brownian motion improves particle dispersion and mixing, which in turn improves heat transfer and reduces localized heating. Brownian motion’s random movement of particles encourages more effective heat distribution throughout the fluid, which lowers peak temperatures and produces a more uniform temperature profile. The temperature profile decreases in tandem with an increase in the Weissenberg number (We). This implies that higher elastic effects in the fluid aid in dissipating energy and improving heat transfer. Figure 7 shows how power law index affects the temperature distribution. This index describes the non-Newtonian rheology of the nanofluid with larger values generally indicating shear-thickening behavior. Viscosity of such fluids is a growing factor of shear rate and a stronger viscous dissipation prevails under flow conditions. This improved frictional heating is more effective in converting mechanical energy to thermal energy leading to high temperature profiles. The interaction of shear-dependent viscosity with heat generation is vital to the study of thermal behavior of non-Newtonian nanofluids in biomedical and engineering studies. Figure 7 is exhibited that with rise of power law index number, increasing temperature for both fluids. The power index number typically characterizes the non-Newtonian behavior of fluids. In many contexts, it determines how the viscosity of the fluid changes with the rate of shear. This implies that higher values of that may indicate shear-thickening behavior lead to higher temperatures due to increased frictional heating. When the shear rate increases, the viscosity increases disproportionately, causing greater viscous dissipation. This increased viscous dissipation converts more mechanical energy into heat, thus raising the fluid's temperature. The impact of increment in volumetric fraction of the graphene nanoparticles on the temperature profile is depicted in Fig. 8, indicating a significant drop in temperature with increment in the value of ϕ. At the physical level, it can be explained by the fact that the effective thermal conductivity of the nanofluid mixture is increased. Graphene nanoparticles are also much more thermally conductive than the underlying blood fluid and thus their greater abundance will enable more efficient heat conduction within the fluid. This enhanced thermal conduction will result in an increase in thermal dissipation, which will decrease localized temperature peaks, resulting in a lower temperature profile overall. Also, the enhancement of the particle concentration can shift the microstructure of the fluid, enhancing thermal conductivity and decreasing thermal resistance. This is essential in biomedical applications, where better heat transfer may be useful in controlling temperatures in microchannels. The volumetric fraction ϕ represents the volume of the graphene nanoparticles in the blood or graphene-blood oxide mixture. An increase in ϕ could indicate a greater concentration of particles, which might lead to changes in the thermal conductivity, heat transfer, or other physical properties of the mixture. As the particle volume fraction increases, the effective thermal conductivity of the mixture generally increases because the particles themselves have higher thermal conductivity. These studies shown in Figs. 9, 10, 11, 12, 13, 14 and 15 depicted that the distribution of nanoparticle concentration are closely connected to the interplay of thermal, mechanical and rheological properties in graphene oxide blood nanofluids in the presence of bionic gyrotactic microorganisms. The knowledge of these physical processes is critical to the optimization of nanofluid preparations and operating conditions in biomedical microchannels, which will guarantee an effective thermal regulation and controlled particles transportation. Changes in different parameters lead to a shift in the fluid concentration distribution, as shown in these figures. Figures 9–15 investigate the effect of different parameters on the concentration distribution of the fluid-nanoparticle mixture and demonstrate complicated interactions between the dynamics of particles and the fluid flow. Figure 9 indicates a reduction in the concentration of the fluid with the volume fraction of nanoparticles as the volume fraction increases. It can be physically attributed to the fact that at higher concentration of nanoparticles, they tend to aggregate or settle, thus reducing the effective free fluid volume. The contact between nanoparticles and the fluid molecules can increase or decrease the mobility of the molecules and diffusion coefficients and hence the fluid concentration gradients. In addition, nanoparticles shape and size can affect their cross sections of interactions and sedimentation, which may also vary the distribution of concentrations, either by facilitating clustering or by suppressing even distributions. This graph shows that there is a trend for the fluid concentration to fall as the fraction of nanoparticles increases. There are several possible explanations for this. For example, the apparent fluid concentration may drop as a result of the nanoparticles starting to settle or coalesce as their concentration rises. Furthermore, nanoparticles may interact with fluid molecules, modifying their mobility or diffusion coefficient, so influencing the overall fluid concentration. As shown in Fig. 10, an increase in Eckert numbers is associated with an increase in the concentration of nanoparticles in blood with both graphene oxide blood nanoparticles and blood nanofluids. Eckert number indicates the dissipation due to viscosity and internal heating; the increase in promotes thermal energy, and the local increase in thermal diffusivity and decrease in viscosity can occur. This heating effect allows greater mixing and dispersion of nanoparticles, avoiding agglomeration and resulting in a more homogenous distribution. Therefore, the effective nanoparticle concentration in the fluid phase increases, indicating the enhancement of suspension stability when more vigorous heating of the suspension happens. The graph shows that the higher the Eckert number, the higher the concentration of both fluids. A greater Eckert number indicates a faster rate of heat transfer, which may improve the fluid’s thermal diffusivity and conductivity. As a result, nanoparticles may be mixed and dispersed more evenly within the fluid, resulting in a larger concentration. Furthermore, the enhanced heat transfer rate may enable a more uniform dispersion of nanoparticles, reduce the possibility of agglomeration or settle. As a result, the fluid’s nanoparticle concentration could be constantly increased. Figure 11 indicates that the parameter of buoyancy ratio has a positive effect on the concentration of nanoparticles, with the effect being stronger in blood than in graphene oxide blood. Increased buoyancy ratio, in the physical sense, increases the intensity of the convection caused by gravity, which enhances vertical mixing and transportation of particles. The enhanced buoyant forces enhance particle suspension by overcoming the sedimentation effect, thereby increasing the level of concentration of the particles in the liquid phase. This variations in the response of blood and graphene oxide blood are due to the different rheological and thermal behaviors of the two substances; blood is more viscous and has more complex composition which might enable its better retention and mixing in the presence of buoyant forces than the graphene oxide mixture. This graph refers to how particles or fluids behave in gravity-driven flows, such as natural convection or sedimentation. The graph shows that as increases, the concentrations of both fluids rise. As may be seen, the concentration of blood grows more than graphene blood oxide. As the buoyancy ratio parameter increases, the buoyancy force becomes more dominant, resulting in increased particle mixing and dispersion within the fluid. As a result, both fluids may be at higher concentrations. The concentration of nanoparticles in blood increases more rapidly with . This may be attributed to the distinctive properties of blood, including its viscosity, thermal conductivity, and the interaction between nanoparticles and blood components. While the concentration also increases for graphene blood oxide with , it does so at a comparatively slower pace than in blood. This could be ascribed to the unique characteristics of graphene blood oxide, which have the potential to influence the distribution of nanoparticles under buoyancy-driven forces. Similarly change in thermophoresis parameter can impact on concentration of fluids by enhancing its values as seen in Fig. 12. Effect of on blood concentration is again higher than graphene blood oxide. With a higher thermophoresis parameter, particles are more inclined to migrate towards regions with lower temperatures, consequently leading to an elevation in their concentration. The augmented thermophoretic force may also amplify temperature-dependent diffusion, thereby enabling particles to diffuse more effectively and resulting in higher concentrations. Thermophoresis causes particles in hotter regions to move towards colder regions, and therefore accumulate in the lower temperature regions. This flow enhances the clustering of particles and the concentration of particles locally. Temperature-dependent diffusion, enhanced by the stronger thermophoretic force, also encourages redistribution of the particles and can result in concentration gradients in line with thermal gradients. A more profound effect on blood might be given by its intricate biological structure that interacts differently with particles that are moving or interacting under thermophoretic forces compared to graphene oxide blood nanofluids. In Figs. 13 and 14, we noticed a trend indicating that as the Brownian parameter and Weissenberg number increase, the concentration distribution for both blood and graphene blood oxide decreases. The Brownian motion becomes more pronounced, leading to a greater diffusion rate of particles. Consequently, the concentration may decrease as particles disperse more evenly throughout the fluid. The increased Brownian motion is associated with amplified random particle motion, which facilitates dispersal and decreased the localized particle concentration thereby decreasing the concentration peaks. The Brownian diffusion increases the diffusion thereby resulting in more homogeneous distributions of the particles. Higher Weissenberg numbers ( indicate a higher degree of non-Newtonian behavior in the fluid, which can impact the settling and mixing of particles. This, in turn, may lead to a concentration decrease, potentially due to alterations in particle–particle interactions or fluid dynamics. Fluid elasticity and non-Newtonian behavior as indicated by the Weissenberg number affects the dynamics of particles due to the flow. As the value of We increases, there are more elastic effects that alter the flow patterns and this may interfere with the particle clustering and increase the mixing effect which helps in reducing the particle concentration by avoiding sedimentation and agglomeration seen in Fig. 14. Figure 15 demonstrates that when the power-law index is increased, it increases the concentration profile. The index of power-law is used to describe the extent of shear-thickening or shear-thinning in the fluid. The shear-thickening is related to higher n values which enhance the resistance of the fluid to shear flow, thus, changing the velocity gradients and favoring the areas of stagnation or recirculation. These disturbed flow patterns impact particle settling and mixing, and usually result in increased retention of particles or localized concentration. The non-Newtonian rheology is therefore important in determining the distribution of nanoparticles by controlling the ratio between the convective transport and diffusion of particles in the fluid. The graph visually shown how an increased power law index results in a more pronounced concentration profile. The higher values cause an increase in non-Newtonian behavior, which can impact flow patterns, velocity profiles, particle settling, and mixing. The microorganisms’ gyrotactic density analysis, conducted from a physical perspective, is depicted in Figures 16, 17, 18, 19, 20, 21, 22 and 23 across different values of the varying parameters. The interaction of hydrodynamic forces, effect of thermal and rheological characteristics in the fluid system can physically explain the gyrotactic density behavior of microorganisms as shown in the figures. It can be seen in Figs. 16, 17 and 18 and that by rising the Eckert number, parameter and parameter respectively, the gyrotactic density increases. This growth of gyrotactic density as Eckert number ) increases can be explained by the fact that the viscous dissipation and consequent thermal energy in the flow increase. Higher Ec implies more transformation of kinetic energy into heat that increases the fluid motion and mixing. This enhanced mixing enables aggregation and active movement of gyrotactic microorganisms and enhances the local density as the microorganisms swim against gravity and decrease the stagnant zones. As increases, the greater kinetic energy can enhance the movement and mixing of gyrotactic microorganisms, leading to a higher gyrotactic density as shown in Fig. 16. On the same note, the parameter of buoyancy ratio is known to affect the gyrotactic density by regulating the forces that act upon the microorganisms due to the buoyancy effect. A high value of increases the strength of these forces, increasing the convective currents that facilitates vertical migration and clustering of microorganisms. This effect increases the concentration of microorganisms in areas where the flow is dominated by buoyancy thereby increasing the density of gyrotactic. An increase in indicates stronger buoyancy forces, which can augment the upward or downward movement of gyrotactic microorganisms, ultimately increasing their density seen in Fig. 17. Moreover, Fig. 18 depicted that with an increase in ​, thermophoresis more effectively drives microorganisms from hotter to cooler regions. This movement can lead to an accumulation of gyrotactic microorganisms, resulting in an increased density in specific areas. Actually, thermophoresis parameter influences the distribution of microorganisms, moving particles towards the colder parts. With increasing , there is an increase in thermophoretic force, causing the microorganisms to migrate in a directed fashion towards cooler regions, causing localized accumulation and higher density. This effect is especially important in temperature ciliated channels where the temperature gradient is strong and has a direct impact on the spatial distribution of microorganisms, and can also impact their biological activity. Conversely, the parameter of Brownian motion has an inverse relationship with the gyrotactic density observed in Fig. 19. Increased Brownian motion increases the random motion of particles, enhancing dispersal and decreasing clustering of microorganisms. This additional randomness breaks up the concentration peaks locally resulting in a more uniform distribution of lower density. This can cause the dispersion of microorganisms and can stop the formation of thick colonies of microorganisms, which are essential to some biological processes. This trend indicated that an increase in the Brownian parameter leads to a decrease in the conditions for microorganism growth for both fluids: blood and graphene oxide blood. A higher Brownian motion results in more extensive dispersion of particles, including microbes. This scattering can cause a more equal distribution of microbes, potentially lower their concentration and clump in a given area. A reduction in concentration and clustering is frequently required to produce the optimal conditions for growth. Figures 20 and 21 demonstrate how the Weissenberg number and the power law index affect gyrotactic density. The observed pattern indicates that greater values of both the Weissenberg number and the power law index resulted in an increase in gyrotactic density. As the number rises, the increased elasticity can influence the motility and clustering of gyrotactic microorganisms, resulting in a larger density. This is due to better alignment and mobility within the fluid. The Weissenberg number () is an indication of the elasticity of the fluid. The higher increases fluid elasticity, which may lead to more effective microorganism alignment and motility as it allows a more organized flow environment. This elasticity enables continuous clustering and directional swimming thus enhancing gyrotactic density. Given the same, an increase in the power-law index indicates shear-thickening behavior, which increases the viscosity of the fluids to shear. This increased viscosity stabilizes aggregates of microorganisms by reducing the turbulent fluctuations and dispersion due to shear, which promotes increased gyrotactic density, a greater power law index results in increased viscosity at higher shear rates. This, in turn, produces more favorable and stable circumstances for the formation and proliferation of gyrotactic bacteria, resulting in increased density. Contribution of volumetric flow is portrayed in Fig. 22 which demonstrate that lessens in gyrotactic density with rise in . Increasing the volume of the fluid increases the concentration of particles. This overcrowding can then interfere with the movement and alignment of gyrotactic microorganisms, hindering their ability to form aggregates. As a result, the overall gyrotactic density decreases. Gyrotactic density is negatively proportional to the volumetric fraction of the nanoparticles. Even though higher will lead to high particle concentration, it could cause overcrowding, which will obstruct movement and alignment of microorganisms physically. This crowding effect minimizes effectiveness in orienting and swimming of microorganisms and results in less density and aggregation. Figure 23 depicts the correlation between the Peclet number and its effect on gyrotactic density. The graph clearly shows that as the number increases, so does the gyrotactic density. As the Pe number increases, the convective transport of microorganisms becomes more significant, leading to more efficient flow and potentially higher concentrations in specific regions. Gyrotactic density is positively correlated with the Peclet number which is the ratio of the convective to the diffusive transport. Higher enhances the convective flows which are more effective in bringing microorganisms to particular areas making them become concentrated in particular locations making them denser. This increased convection is capable of conquering diffusive spreading, and concentrates microorganisms in growth or interaction favored regions. Peristaltic pumping is a process in which the walls of a tube or channel contract and relax sequentially. These contractions move in a wave-like motion along the length of the tube, resulting in areas of high and low pressure. The pressure difference between the high-pressure zone (caused by the contractions) and the low-pressure zone (caused by the relaxations) creates a pressure gradient. On the aspect of pressure gradient dynamics, peristaltic pumping creates spatially dissimilar pressure field as a result of successive contractile and relaxations of the walls. Figures 24, 25, 26, 27 and 28 collectively present a comprehensive overview of how different parameters affect the pressure gradient in the system. As Fig. 24 shows, the pressure gradient increases with the Grashof number (), or the effects of buoyancy as compared to the viscous forces. The increased buoyancy forces enhance fluid movement and pressure gradient along the channel affecting the movement of microorganisms and heat transfer. Pressure gradient development in response to alterations in the Grashoff number is manifested in this Fig. 24. On the other hand, Fig. 25 indicates that the pressure gradient decreases with the increase in the power law index Shear-thickening effect with greater values enhance the fluid viscosity at high shear rates, capable of neutralizing the velocity gradient of the flow and even-out the pressure fluctuations. Figure 25 Shows how the power law index () affects the pressure gradient, providing insights into the non-Newtonian characteristics of the fluid. With increase in , the pressure gradient decreases. This rheology effect balances forces of fluid flow and transportation of microorganisms, which influence the system dynamics. Figure 26 illustrates the impact of the volumetric fraction (ϕ) on the pressure gradient, highlighting the role of particle concentration in determining the fluid’s resistance to flow. As ϕ increases, pressure gradient decreases for higher Grashoff number. Figure 27 shows the effect of the chemical reaction parameter ϭ on the pressure gradient. The graph likely indicates how changes in ϭ impact the fluid’s behavior and the resulting pressure gradient, with rising values of ϭ, rises. This implies that higher values of σ contribute to increased resistance to flow, thereby requiring a larger pressure gradient to sustain the same flow rate. Figure 28 depicts the influence of the Weissenberg number (We) on the pressure gradient, emphasizing the role of elastic effects. It can be visualized that pressure gradient decreases by increasing number. Figures 29, 30, 31 and 32 demonstrate the sophisticated interdependence of the main parameters on the pressure increase with the flow rate of the peristaltic pumping system which exhibit specific regimes of operation: the peristaltic pumping region, free pumping region and augmented pumping region. All these findings combine to give a complete physical knowledge of the interaction between the three parameters of buoyancy, rheology, loading of nanoparticles, and flow rate to control the pressure generation and fluid transport within peristaltic systems. They emphasize that such parameters need to be carefully adjusted to ensure that pumping, thermal, and fluid dynamics are optimized in applications where a complex nanofluid containing embedded bionic microorganisms is used. In Fig. 29, the effect of the Grashof number on the rise in pressure is emphasized. At a given flow rate, the free pumping region is observed where the pressure increase with the increase in is noticed. Physically, this is possible since the Grashof number is a measure of the relative strength of the buoyancy forces with regards to the viscous forces. The stronger the Gr the stronger the convection due to buoyancy and the stronger the fluid motion generated and the pressure gradient. This enhanced pressure facilitates easier fluid propulsion by the peristaltic waves, especially in thermally stratified surroundings that the peristaltic waves complement mechanical pumping. It can be seen in this Fig. 29 that there is a free pumping region at and then pressure rise increases with increase in number. As the Grashoff number increases, the significance of buoyancy forces relative to viscous forces also increases. This heightened buoyancy effect leads to a greater pressure increase within the fluid. Effects of power law index n is seen in Fig. 30. This shows that power law index has a definite impact on the pressure increase where the higher the , the higher the pressure and a free pumping region at a given flow rate. The power-law index describes the non-Newtonian behavior of the fluid; values of are higher as the fluid is shear-thickening, viscosity is proportional to the shear rate. This increased viscosity during conditions of flow increases resistance of fluid motion, and thus requires an increase in pressure gradient to sustain the same flow rate. The pressure rise, therefore, corresponds to the extra work of mechanical nature needed to overcome the increased viscous resistance that is present in shear-thickening fluids. Pressure rise increases with rise in , and free pumping region can be seen at . Figure 31 illustrates the influence of parameter ϕ on pressure rise. Free pumping region is at and pressure rise increases for and decrease for . Actually, Fig. 31 looks into the volumetric nanoparticle fraction and its twofold effect on the increase in pressure. It is observed that the free pumping region is reached at a specific flow rate and the increase of pressure rises in specific ranges of and in certain ranges of ϕ it decreases. Physically, raising raises the effective viscosity and density of the nanofluid, which changes in the rheology of the nanofluid. Moderate values momentum transfer and pressure generation can be enhanced by the presence of nanoparticles because of enhanced fluid solid interactions. However, at a certain point, further loading of the particles will cause particle agglomeration or higher flow resistance with decreased pressure increase. This non-monotonic effect highlights the exquisite tradeoff between the increased thermal and mechanical attributes and the disadvantages of crowding the particles. Role of number on pressure rise can be seen in Fig. 32. It can be observed that free pumping region is at and pressure rise increases for . It concentrates on how an extra parameter (probably a flow or thermal parameter but here is an unspecified parameter) affects the increase in pressure, and indicates a free pumping region at a zero flow rate and a further accelerating pressure rise with the increase in parameter. This trend indicates that this parameter increases the driving forces or alters fluid properties to enable more pressure to be developed under the effect of peristaltic action, perhaps by affecting viscosity, elasticity or thermal gradients that influence fluid momentum and pressure distribution. Peristaltic motion creates pressure gradients in channel walls, causing fluid to move in a wave-like manner. This can induce internally circulating streamlines, which form a bolus or packet of fluid, which is carried downstream through the channel due to the fluid’s rheological properties. The peristaltic motion automatically creates pressure gradients in the channel walls, by sequential contractions and relaxations, and creates internally circulating streamlines that create discrete boluses of fluid carried downstream. Figures 33 and 34 give pictures of these phenomena through streamline and temperature contour plots at different average flow rates ). In these Figs. 33 and 34, streamline and temperature contours are plotted to represent different physical parameter for different values. The graphs obtained from this analysis are then examined from a physical perspective. As we can see in both figures for streamlines and temperatures contours respectively, the size and no of boluses decreases with increase in average flow rate. We can also observe that number of streamlines also decreases with increase value of Q. This suggests that increasing the flow rates results in improved fluid movement efficiency, which helps to reduce the formation of stagnant or trapped regions within the fluid. Physically, with increase in , there is a decrease in size and number of boluses and the streamlines become fewer. This implies that increased flow rates will ensure that there is increased streamlined and efficient fluid transport that reduces recirculation zones and stagnant areas. This decrease in bolus formation and streamline complexity boosts mixing and heat transfer efficiency by eliminating localized trapping of fluid parcels which may hinder transport in general. These findings underscore the need to optimize the flow rate in order to achieve optimal pumping and minimum flow resistance as well as thermal inefficiencies. The decrease in bolus size, number of boluses, and streamline complexity as the flow rate (Q) increases highlights the significance of optimizing flow rate to improve fluid dynamics and system efficiency. Finally Figs. 35 and 36 exhibits the influence of nanoparticle volume fraction on streamline and temperature contours. Both of these figures depict that by enhancing the nanoparticle volume fraction streamline and temperature contours are least affected. These Figs. 35 and 36 are on the effect of the nanoparticle volume fraction increase on streamline and temperature contours. The fact that very little changes are noticed in both patterns of streamlines and temperature distribution indicates that at the range of study, a change in the concentration of the nanoparticles do not cause significant alteration in the overall flow structure or thermal field. This stability means that the nanofluid has a steady hydrodynamic and thermal behaviour even as is varied, which is beneficial in applications where it is important to have a predictable flow and heat transfer behaviour. The strength of the flow and temperature fields to the changes in the nanoparticles loading indicates the possibility of using graphene oxide blood nanofluids in biomedical microchannels without affecting the performance of the pumping system and thermal control. Concluding remarks This paper discusses in-depth research on the electroosmotic transport of a Carreau nanofluid with gyrotactic microorganisms in a vertical ciliated channel. The findings provide valuable understanding of the interplay of non-Newtonian rheology, electro kinetics, nanoparticle dynamics, and microorganism dynamics. The shear-thinning property of the Carreau fluid changes considerably the flow structure, the power-law index is used to regulate the effective viscosity, and therewith to regulate velocity distribution and transport processes. Reduced viscosity with increased shear rates increases fluid mobility and this is especially useful in the microfluidic conditions. The forces that dominate to drive the flow are electroosmotic forcing. There are effects of increasing the Peclet number which increases the strength of the convective transport, leading to increased migration, accumulation of gyrotactic microorganisms. In controlled transport systems, this mechanism is particularly helpful, with external electric fields being able to manipulate biological suspensions. Addition of nanoparticles (e.g., graphene oxide) contributes significantly to thermal performance of the fluid. The parameters that improve the rate of heat transfer include nanoparticle volume fraction and Brownian motion parameter () which can also decrease the density of gyrotactic microorganisms since there is increased agitation and dispersion of the particles. This means that there is a trade off between thermal efficiency and biological stability. Moreover, the Weissenberg number buoyancy ratio parameter and thermophoretic parameter () have a significant effect on the microorganism distribution. An increase in these parameters will facilitate orientation and aggregation of microorganisms, enhancing bioconvection patterns. Nevertheless, too much Brownian motion may disrupt such organization and decrease efficiency of systems. The implications on the findings of this study include a number of applications in real world: The synergic action between electroosmosis and ciliary movement may find application in drug delivery systems, lab-on-chip systems and microfluidic pumps, where the control of fluid and biological objects is needed. The capability to regulate nanoparticle dispersal and movement of microorganisms with the help of electric fields and fluid parameter can be utilized in targeted therapy, particularly in the blood-like nanofluids. Gyrotactic microorganisms can be used in the biosensors, microbial fuel cells and bioconvection-based mixing systems to improve efficiencies by taking advantage of their behavior. Nanofluids that exhibit improved heat transfer can be used in cooling devices, like micro heat exchangers and biomedical cooling devices. The designed ciliated channel has insights into the design of bio-inspired pumping systems, which can be applicable in the microfluidic transport without mechanical components. All in all, this research paper offers a theoretical basis of the optimization of the electroosmotic nanofluids transport in biological active systems. The findings demonstrate the significance of a compromise between thermal improvement and stabilization of microorganisms, and provide useful insights in designing new biomedical and engineering devices. Acknowledgements The authors extend their appreciation to the Deanship of Research and Graduate Studies at King Khalid University, KSA for funding this work through Large Research Project under grant number RGP.2/108/47. List of symbols Rectangular coordinates Thermal expansion coefficient Components of velocity Temperature at channel centre Concentration at channel centre Temperature at channel wall Concentration at channel wall Channel wall Half- width inlet Channel’s length dependent constant Chemotaxis parameter Boltzmann constant Mean temperature Reaction rate Non-dimensional temperature Nanoparticle concentration Brinkmann number Heat capacitance Thermophoretic parameter Brownian diffusion parameter Cilia length parameter Dynamic viscosity Radius of tube Effective thermal conductivity. Microorganism concentration Activation energy Time parameter Eckert number Prandtl number Thermal radiation parameter Grashof number Channel wall (Non-dimensional) Wavelength Wave speed Volumetric flow rate Amplitude ratio Helmholtz-Smoluchowski velocity or electroosmotic velocity parameter Diffusion parameter of microorganism Microorganism’s swimming speed Brownian motion parameter Thermophoretic parameter Lewis number Thermal Biot number Buoyancy ratio parameter Peclet number Bioconvection Lewis number Bioconvection Rayleigh number Electroosmotic velocity parameter Chemical reaction parameter Flow rate Weissenberg number Power index number Local Reynolds number Subscripts Nanofluid Solid particle Author contributions *Madiha Ajmal*: Methodology Section; Formal Analysis; Visualization; Manuscript Writing, ***Rashid Mehmood***: Software; Formal Analysis; Visualization; Manuscript Writing, **Noreen Sher Akbar**: Mathematical formulation; Conceptualization; validation; Manuscript Writing; ***Siddra Rana***; Formal Analysis;Validation; Review manuscript Writing. ***Lemessa Asefa Eressa***: Formal Analysis; Validation; Review manuscript Writing. ***Taseer Muhammad***: Formal Analysis; Validation; Vizulization; Review manuscript Writing. Data availability The datasets generated during and/or analysed during the current study are available from the corresponding author on reasonable request. Declarations Ethics approval and consent to participate Not applicable. Consent for publication Not applicable. Competing interests The authors declare no competing interest. Footnotes Publisher's Note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations. Contributor Information Madiha Ajmal, Email: madihahitecuni@gmail.com. Lemessa Asefa Eressa, Email: lemessa.asefa@ambou.edu.et. References Associated Data Data Availability Statement The datasets generated during and/or analysed during the current study are available from the corresponding author on reasonable request.