Protocol for total RNA sequencing analysis of extracellular RNA from biofluids Authors: Anneleen Decock, Kimberly Verniers, Philippe Decruyenaere, Annelien Morlion, Jasper Verwilt Published: 2026 ABSTRACT SummaryExtracellular or cell-free RNAs (exRNAs) derived from biofluids are utilized in biomarker studies to study health and diseases. Here, we present a protocol for total RNA sequencing analysis of blood plasma exRNA using the Switching Mechanism At 5′ end of RNA Template (SMART) cDNA synthesis technology. We describe all steps, from blood plasma preparation to sequencing data analysis. In addition to blood plasma, this protocol can also be applied to exRNA purified from other human, murine, and rat biofluids.For complete details on the use and execution of this protocol, please refer to Decruyenaere et al.1Subject areas: Sequence analysis, Sequencing, RNA-seq Before you begin The protocol below describes the wet and dry lab steps for total RNA sequencing analysis of cell-free RNA (extracellular RNA, exRNA) purified from human, murine, or rat blood plasma, using the Switching Mechanism At 5′ end of RNA Template (SMART) cDNA synthesis technology developed by Takara Bio.1,2,3,4,5 More specifically, we explain how to prepare and quantify strand-specific, ribosomal RNA (rRNA)-depleted sequencing libraries from DNase-treated exRNA, using the SMARTer Stranded Total RNA-Seq Kit v3 – Pico Input Mammalian, or a reconfigured version of this kit, i.e., the SMART-Seq Total RNA Pico Input with UMIs (ZapR Mammalian) kit. Figure 1 summarizes the underlying principles of the library preparation, as well as the corresponding wet lab steps described in this section. This technology has also been used to profile exRNA purified from human urine3 and seminal plasma,6 from conditioned medium from cancer cells,3 and from blood plasma-, urine- and conditioned medium-derived extracellular vesicles.3 Note: The SMARTer Stranded Total RNA-Seq Kit v3 – Pico Input Mammalian and the SMART-Seq Total RNA Pico Input with UMIs (ZapR Mammalian) kit are updated versions of the SMARTer Stranded Total RNA-Seq Kit v2 – Pico Input Mammalian (Cat#634411-634414 (with indexing primers) or Cat#634417-634419 (without indexing primers), Takara Bio). Also, this v2 version of the kit has been successfully applied to exRNA purified from liquid biopsies.3,4,5,6 Note that Takara Bio has communicated the phasing out of both the v2 and v3 versions of the kit. Therefore, we recommend to use the SMART-Seq Total RNA Pico Input with UMIs (ZapR Mammalian) kit for new studies. Furthermore, we recommend not to combine reagents from different kit versions, nor using different kit versions within a single experiment or study. Schematic overview of the different steps in the total RNA sequencing library preparation workflow using the SMARTer Stranded Total RNA-Seq Kit v3 – Pico Input Mammalian or the SMART-Seq Total RNA Pico Input with UMIs (ZapR Mammalian) kit (A) The 1st-strand cDNA synthesis step starts with a DNase-treated, spike-in-supplemented RNA sample and involves total RNA fragmentation and cDNA synthesis. Random priming allows the generation of cDNA from all RNA fragments in the sample, including rRNA. When the SMARTScribe II Reverse Transcriptase reaches the 5′ end of the RNA fragment, the enzyme’s terminal transferase activity tails a few non-templated nucleotides to the 3′ end of the cDNA (shown as XXXXX). The SMART UMI Adapter (included in the SMART UMI-TSO Mix v3) base-pairs with the non-templated nucleotide stretch, initiating second-strand synthesis upon template switching, and contains 8 random nucleotides, which function as unique molecular identifiers (UMIs) in downstream analyses. (B) In the next step, adapters for Illumina sequencing, including P5/P7 and i5/i7 indexes for flow cell clustering as well as regions recognized by sequencing primers for Read 1 and 2, are added via a first round of PCR amplification. The 5′ PCR primer binds to the SMART UMI Adapter sequence. The 3′ PCR primer binds to the sequence associated with the random primer. (C) Ribosomal cDNA is then cleaved by ZapR Enzyme in the presence of mammalian-specific R-Probes. Non-ribosomal molecules are left untouched, with priming sites available on both 5ʹ and 3ʹ ends for further PCR amplification. (D) The intact molecules are enriched by a second PCR amplification using P5/P7 primers, which are universal across all Illumina libraries. Read 1 generates sequences antisense to the original RNA, while Read 2 yields sequences sense to the original RNA. The first 8 nt of the second sequencing read (Read 2) are UMIs followed by 3 nucleotides of UMI-linker and 3 nontemplated nucleotides derived from the SMART UMI Adapter. Lastly, the PCR products are purified once more to yield the final cDNA library. The figure is based on the manufacturer’s manuals and was partly created in BioRender (Mestdagh, P. (2026) https://BioRender.com/qk3ojod). FMM: Fragmentation Master Mix; FSMM: First-Strand Master Mix; P1MM: PCR1 Master Mix; ZMM: ZapR Master Mix; P2MM: PCR2 Master Mix. Innovation This protocol is based on Takara Bio total RNA sequencing library preparation manuals (SMARTer Stranded Total RNA-Seq Kit v3 – Pico Input Mammalian and SMART-Seq Total RNA Pico Input with UMIs (ZapR Mammalian)), with specific optimizations for exRNA isolated from liquid biopsies. Such RNA is typically present at very low concentrations and is highly fragmented, but profiling of these conditions is not fully addressed in existing protocols. We provide detailed guidance and quality control steps tailored to exRNA inputs to ensure robust and reproducible library preparation. The protocol includes instructions for manual execution as proposed in the original manuals, as well as for semi-automated execution, enabling scalable, high-throughput processing while reducing operator-dependent variability. We also describe how the workflow can be further automated to support implementation in large studies. To improve usability and reproducibility, we provide templates for experimental design and sequencing setup, as well as a user-friendly computational processing pipeline with test data. This end-to-end workflow enables users to run, evaluate, and adapt the protocol, guided by comprehensive quality control checks. Institutional permissions To collect human or animal biofluids, institutional regulations may legally require researchers to obtain ethical approval from the competent ethics committee of the host institution. Here, human blood plasma data of Decruyenaere et al.1 were used, a study approved by the ethics committee of Ghent University Hospital (Ghent, Belgium; approval number EC/2016/0307). Written informed consent was obtained from all study participants.1 Blood plasma preparation Timing: ∼2 h CRITICAL: Note that different blood plasma preparation protocols may be used. However, pre-analytical variables highly impact the quantification of blood plasma-derived exRNAs.7 Therefore, we recommend standardizing blood sample collection and processing within a single study. Combining data from different blood collection tube types and/or different blood processing time intervals will introduce unacceptable biases into the results. We advise using citrate blood collection tubes and completing blood plasma preparation within 4 hours after collection.7 The use of manufacturer-designated preservation tubes (such as the Cell-Free RNA BCT, Cell-Free DNA BCT, PAXgene Blood ccfDNA Tube, or Cell-Free DNA Collection Tube) should be avoided for exRNA profiling.7 Here, we describe the preparation of double-spun plasma from whole blood collected in Vacuette 9 mL, sodium citrate 3.2% blood collection tubes, following the International Society on Thrombosis and Haemostasis (ISTH) guidelines. The resulting plasma is directly suitable for exRNA profiling, but can also be used for extracellular vesicle purification and subsequent exRNA profiling.3,8 1.Collect human venous blood from an elbow vein using a BD Vacutainer Push Button Blood Collection Set in Vacuette 9 mL, sodium citrate 3.2% blood collection tubes. Fill the blood collection tubes to the manufacturer’s recommended volume. Collect human venous blood from an elbow vein using a BD Vacutainer Push Button Blood Collection Set in Vacuette 9 mL, sodium citrate 3.2% blood collection tubes. Fill the blood collection tubes to the manufacturer’s recommended volume. 2.Immediately after the blood draw, invert the blood collection tubes 5 times to mix the anticoagulant with the blood, then transport them at room temperature (18°C–22°C) to the lab for further processing. Immediately after the blood draw, invert the blood collection tubes 5 times to mix the anticoagulant with the blood, then transport them at room temperature (18°C–22°C) to the lab for further processing. Note: All centrifugation steps during the blood plasma preparation protocol are performed at room temperature (18°C–22°C) in a centrifuge with swinging bucket rotor and appropriate adapters, for example, a Centrifuge 5804 with rotor A-4-44 and adapters for blood collection tubes or 15 mL conical tubes. No or minimal acceleration and braking should be applied. 3.Before initiating the first centrifugation step, invert the blood collection tubes five times. Before initiating the first centrifugation step, invert the blood collection tubes five times. 4.Prepare single-spun plasma:a.Centrifuge the blood tubes at 2500 g for 15 min.b.Carefully transfer the plasma using a 1 mL pipette to a 15 mL conical tube, leaving approximately 0.5 cm above the buffy coat. Do not touch the buffy coat with the pipette tip.Note: Try not to disturb the buffy coat layer when preparing plasma. Carry-over of white blood cells and platelets from the buffy coat is the most likely source of cellular RNA contamination.c.Invert the 15 mL tube five times. Immediately continue with the next step. Prepare single-spun plasma:a.Centrifuge the blood tubes at 2500 g for 15 min.b.Carefully transfer the plasma using a 1 mL pipette to a 15 mL conical tube, leaving approximately 0.5 cm above the buffy coat. Do not touch the buffy coat with the pipette tip.Note: Try not to disturb the buffy coat layer when preparing plasma. Carry-over of white blood cells and platelets from the buffy coat is the most likely source of cellular RNA contamination.c.Invert the 15 mL tube five times. Immediately continue with the next step. a.Centrifuge the blood tubes at 2500 g for 15 min. Centrifuge the blood tubes at 2500 g for 15 min. b.Carefully transfer the plasma using a 1 mL pipette to a 15 mL conical tube, leaving approximately 0.5 cm above the buffy coat. Do not touch the buffy coat with the pipette tip.Note: Try not to disturb the buffy coat layer when preparing plasma. Carry-over of white blood cells and platelets from the buffy coat is the most likely source of cellular RNA contamination. Carefully transfer the plasma using a 1 mL pipette to a 15 mL conical tube, leaving approximately 0.5 cm above the buffy coat. Do not touch the buffy coat with the pipette tip.Note: Try not to disturb the buffy coat layer when preparing plasma. Carry-over of white blood cells and platelets from the buffy coat is the most likely source of cellular RNA contamination. Note: Try not to disturb the buffy coat layer when preparing plasma. Carry-over of white blood cells and platelets from the buffy coat is the most likely source of cellular RNA contamination. c.Invert the 15 mL tube five times. Immediately continue with the next step. Invert the 15 mL tube five times. Immediately continue with the next step. 5.Prepare double-spun plasma:a.Centrifuge the 15 mL tube at 2500 g for 15 min.b.Carefully transfer the plasma using a 1 mL pipette to a fresh 15 mL tube, leaving approximately 0.5 cm above the platelet pellet. Do not touch the pellet with the pipette tip.c.Invert the 15 mL tube five times. Immediately continue with the next step. Prepare double-spun plasma:a.Centrifuge the 15 mL tube at 2500 g for 15 min.b.Carefully transfer the plasma using a 1 mL pipette to a fresh 15 mL tube, leaving approximately 0.5 cm above the platelet pellet. Do not touch the pellet with the pipette tip.c.Invert the 15 mL tube five times. Immediately continue with the next step. a.Centrifuge the 15 mL tube at 2500 g for 15 min. Centrifuge the 15 mL tube at 2500 g for 15 min. b.Carefully transfer the plasma using a 1 mL pipette to a fresh 15 mL tube, leaving approximately 0.5 cm above the platelet pellet. Do not touch the pellet with the pipette tip. Carefully transfer the plasma using a 1 mL pipette to a fresh 15 mL tube, leaving approximately 0.5 cm above the platelet pellet. Do not touch the pellet with the pipette tip. c.Invert the 15 mL tube five times. Immediately continue with the next step. Invert the 15 mL tube five times. Immediately continue with the next step. 6.Aliquot the double-spun plasma into 1.5 mL LoBind tubes, snap freeze in liquid nitrogen, and store at −80°C. Aliquot the double-spun plasma into 1.5 mL LoBind tubes, snap freeze in liquid nitrogen, and store at −80°C. Note: To avoid freeze-thaw cycles and volume loss during pipetting, we recommend storing aliquots that can be used immediately as input volume for RNA purification (e.g., 200 μL plasma for the miRNeasy Serum/Plasma Kit). Note: The number of centrifugation steps, and centrifugation speed and time impact the level of remaining blood platelets in the obtained plasma. ExRNA profiles from plasma with high platelet levels will be dominated by platelet RNA. To reduce the platelet RNA signal in the sequencing data, we recommend to centrifuge at least once at 2500 g for 15 min.4 Note: Using the aforementioned protocol, a completely filled blood collection tube yields approximately 3–5 mL of single-spun plasma, depending on the donor. RNA purification and genomic DNA removal using spike-in RNA Timing: ∼3 h CRITICAL: Note that different RNA purification methods may be used to purify exRNA from blood plasma, considering compatibility with the selected downstream genomic DNA removal method.7 Keep in mind, however, that the choice of RNA purification method also impacts exRNA quantification.7 Therefore, we recommend standardizing processing methods within a single study. Combining data derived from different RNA purification methods will introduce unacceptable biases in the results. We advise to maximize the blood plasma input volume and recommend to use the miRNeasy Serum/Plasma Kit or miRNeasy Serum/Plasma Advanced Kit (for blood plasma input volumes of 0.2–0.6 mL), or the QIAamp ccfDNA/RNA Kit (for blood plasma input volumes up to 4 mL) for RNA purification.7 CRITICAL: Furthermore, the use of synthetic spike-in RNA during RNA purification8,10 and before genomic DNA (gDNA) removal is recommended to allow sequencing-based quality control (see Section data analysis in expected outcomes) and optional exRNA normalization.1,2,3,4,9,10 Depending on the applied centrifugation protocol to prepare plasma, different synthetic spike-in RNA dilutions are required. In Table 1, we summarize the recommended Sequin (Garvan Institute of Medical Research)11,12 and External RNA Control Consortium (ERCC) spike-in RNA dilutions for single-spun, double-spun, and triple-spun plasma as prepared in the Extracellular RNA Quality Control Study.7 Table 1Sequin spike-in and External RNA Control Consortium (ERCC) spike-in RNA dilutions for total RNA sequencing of single-spun (SSP), double-spun (DSP), or triple-spun plasma (TSP)Dilution nameDilution relative to stockSequin stockaSequin SSPb1/250Sequin DSPb1/1500Sequin TSPb1/3000ERCC stockaERCC working solution1/250ERCC SSPb1/5000ERCC DSPb1/12,500ERCC TSPb1/25,000aThe Sequin and ERCC spike-in RNA stock dilutions are a mixture of different RNA molecules at varying individual concentrations (see Supplemental information of Hulstaert et al.9). Note that only these individual RNA molecule concentrations are shared by the suppliers of these spike-in RNAs. Therefore, dilutions here are volume-based and not concentration-based. Dilutions are made using nuclease-free water.bSSP, DSP, and TSP are as prepared in the Extracellular RNA Quality Control study.7 Briefly, three successive centrifugation steps were performed, i.e., a first centrifugation step of 20 min at 400 g (resulting in SSP), followed by 10 min at 800 g (resulting in DSP), and a final centrifugation step of 15 min at 2500 g (resulting in TSP). Sequin spike-in and External RNA Control Consortium (ERCC) spike-in RNA dilutions for total RNA sequencing of single-spun (SSP), double-spun (DSP), or triple-spun plasma (TSP) The Sequin and ERCC spike-in RNA stock dilutions are a mixture of different RNA molecules at varying individual concentrations (see Supplemental information of Hulstaert et al.9). Note that only these individual RNA molecule concentrations are shared by the suppliers of these spike-in RNAs. Therefore, dilutions here are volume-based and not concentration-based. Dilutions are made using nuclease-free water. SSP, DSP, and TSP are as prepared in the Extracellular RNA Quality Control study.7 Briefly, three successive centrifugation steps were performed, i.e., a first centrifugation step of 20 min at 400 g (resulting in SSP), followed by 10 min at 800 g (resulting in DSP), and a final centrifugation step of 15 min at 2500 g (resulting in TSP). Here, we describe RNA purification using the miRNeasy Serum/Plasma Kit and gDNA removal using HL-dsDNAse and Reaction buffer from 200 µL plasma prepared as described in the Section blood plasma preparation. 7.Follow the step-by-step details described in Hulstaert et al.,9 section RNA purification (step 1–11) and genomic DNA removal (step 12–21).a.In step 2 of Hulstaert et al., use 2 μL of Sequin TSP dilution (Table 1).Note: The volume of Sequin dilution to be added to the lysate depends on the blood plasma input volume used for RNA purification. Per 100 μL of plasma input, 1 μL of the appropriate Sequin dilution (Table 1) is added to the sample lysate.b.In step 16 of Hulstaert et al., use 2 μL of ERCC TSP dilution (Table 1).Note: The volume of ERCC spike-in RNAs to be added to the RNA eluate depends on the eluate volume used for gDNA removal. Per 12 μL of RNA eluate, 2 μL of the appropriate ERCC dilution (Table 1) is added to the RNA sample.Note: Sequin and ERCC spike-in RNA dilutions for profiling of human urine, conditioned medium from cancer cells, and extracellular vesicles, and for profiling of seminal plasma are indicated in Everaert et al.3 and Morlion et al.,6 respectively. Follow the step-by-step details described in Hulstaert et al.,9 section RNA purification (step 1–11) and genomic DNA removal (step 12–21).a.In step 2 of Hulstaert et al., use 2 μL of Sequin TSP dilution (Table 1).Note: The volume of Sequin dilution to be added to the lysate depends on the blood plasma input volume used for RNA purification. Per 100 μL of plasma input, 1 μL of the appropriate Sequin dilution (Table 1) is added to the sample lysate.b.In step 16 of Hulstaert et al., use 2 μL of ERCC TSP dilution (Table 1).Note: The volume of ERCC spike-in RNAs to be added to the RNA eluate depends on the eluate volume used for gDNA removal. Per 12 μL of RNA eluate, 2 μL of the appropriate ERCC dilution (Table 1) is added to the RNA sample.Note: Sequin and ERCC spike-in RNA dilutions for profiling of human urine, conditioned medium from cancer cells, and extracellular vesicles, and for profiling of seminal plasma are indicated in Everaert et al.3 and Morlion et al.,6 respectively. a.In step 2 of Hulstaert et al., use 2 μL of Sequin TSP dilution (Table 1).Note: The volume of Sequin dilution to be added to the lysate depends on the blood plasma input volume used for RNA purification. Per 100 μL of plasma input, 1 μL of the appropriate Sequin dilution (Table 1) is added to the sample lysate. In step 2 of Hulstaert et al., use 2 μL of Sequin TSP dilution (Table 1).Note: The volume of Sequin dilution to be added to the lysate depends on the blood plasma input volume used for RNA purification. Per 100 μL of plasma input, 1 μL of the appropriate Sequin dilution (Table 1) is added to the sample lysate. Note: The volume of Sequin dilution to be added to the lysate depends on the blood plasma input volume used for RNA purification. Per 100 μL of plasma input, 1 μL of the appropriate Sequin dilution (Table 1) is added to the sample lysate. b.In step 16 of Hulstaert et al., use 2 μL of ERCC TSP dilution (Table 1).Note: The volume of ERCC spike-in RNAs to be added to the RNA eluate depends on the eluate volume used for gDNA removal. Per 12 μL of RNA eluate, 2 μL of the appropriate ERCC dilution (Table 1) is added to the RNA sample.Note: Sequin and ERCC spike-in RNA dilutions for profiling of human urine, conditioned medium from cancer cells, and extracellular vesicles, and for profiling of seminal plasma are indicated in Everaert et al.3 and Morlion et al.,6 respectively. In step 16 of Hulstaert et al., use 2 μL of ERCC TSP dilution (Table 1).Note: The volume of ERCC spike-in RNAs to be added to the RNA eluate depends on the eluate volume used for gDNA removal. Per 12 μL of RNA eluate, 2 μL of the appropriate ERCC dilution (Table 1) is added to the RNA sample.Note: Sequin and ERCC spike-in RNA dilutions for profiling of human urine, conditioned medium from cancer cells, and extracellular vesicles, and for profiling of seminal plasma are indicated in Everaert et al.3 and Morlion et al.,6 respectively. Note: The volume of ERCC spike-in RNAs to be added to the RNA eluate depends on the eluate volume used for gDNA removal. Per 12 μL of RNA eluate, 2 μL of the appropriate ERCC dilution (Table 1) is added to the RNA sample. Note: Sequin and ERCC spike-in RNA dilutions for profiling of human urine, conditioned medium from cancer cells, and extracellular vesicles, and for profiling of seminal plasma are indicated in Everaert et al.3 and Morlion et al.,6 respectively. 8.Store DNase-treated and spike-in-supplemented RNA eluates at −80°C. Avoid multiple freeze-thaw cycles. Store DNase-treated and spike-in-supplemented RNA eluates at −80°C. Avoid multiple freeze-thaw cycles. Experimental design of the library preparation Timing: ∼15 min The protocol described in the Section step-by-step method details is based on the manufacturer’s manuals (SMARTer Stranded Total RNA-Seq Kit v3 – Pico Input Mammalian and SMART-Seq Total RNA Pico Input with UMIs (ZapR Mammalian) manuals) for the library preparation protocol of a single sample using monochannel pipettes. For profiling of multiple samples, the experimental template in File S1 can be used to set up the library plate layout and to calculate the reagent volumes required to prepare the different master mixes throughout the protocol, as well as to determine how to aliquot these master mixes into the library plate, depending on the number of samples being profiled. In addition, the Section step-by-step method details provides details for executing the protocol using (electronic) multichannel pipettes (see key resources table for complete list and matching pipetting tips) and/or semi-automated pipetting (using the VIAFLO 96 and Mantis Liquid Dispenser (with silicone high volume chips)) to accelerate profiling of large sample numbers. Although manual pipetting (using electronic multichannel pipettes) can be used to process up to 96 samples simultaneously, we recommend using semi-automated pipetting for sample numbers greater than 32. It should be noted that the semi-automated pipetting instructions require more reagents than manual pipetting does, due to allowances for dead volume. One must consider whether the benefits of faster library preparation outweigh the cost of increased reagent consumption. In the protocol steps, it is indicated which pipetting option(s) can be used: multichannel pipetting, Mantis, or VIAFLO 96. For the protocol steps that use the Mantis Liquid Dispenser, the time required to add the master mix to different sample numbers is summarized in Table 2. For protocol steps in which the VIAFLO 96 can be used, the appropriate electronic pipetting speed settings are specified in the protocol description. Note: For all VIAFLO 96 steps, it is recommended to use the ‘tip touch’ technique: lightly touch the GripTips to the side of the well, or briefly dip them into the liquid after dispensing, to ensure complete liquid release and minimize carryover. Table 2Dispense time of the Mantis Liquid Dispenser for each of the master mixes used in the library preparation protocol, depending on the number of samples being profiledSample number5 μL of FMM (min:s)7 μL of FSMM (min:s)28 μL of P1MM (min:s)80 μL of P2MM (min:s)800:2800:3800:4701:041600:3200:4601:0401:442400:3500:5401:2202:243200:3901:0201:3903:034000:4201:1001:5603:434800:4601:1802:1404:225600:4901:2602:3105:026400:5301:3402:4905:427200:5601:4203:0706:218001:0001:5103:2407:018801:0401:5903:4207:419601:0702:0704:0008:21FMM, Fragmentation Master Mix; FSMM, First-Strand Master Mix; P1MM, PCR1 Master Mix; P2MM, PCR2 Master Mix. Dispense time of the Mantis Liquid Dispenser for each of the master mixes used in the library preparation protocol, depending on the number of samples being profiled FMM, Fragmentation Master Mix; FSMM, First-Strand Master Mix; P1MM, PCR1 Master Mix; P2MM, PCR2 Master Mix. Unique dual-indexed PCR primers Timing: ∼10 min To discriminate pooled libraries, unique dual-indexed PCR primers (UDIs) are used to generate indexed Illumina-compatible next-generation sequencing libraries (see Section first-strand cDNA synthesis, step 15). 9.Select the correct UDIs, depending on the library preparation kit version used and the number of samples that need to be pooled.a.Using the SMARTer Stranded Total RNA-Seq Kit v3 – Pico Input Mammalian:i.For up to 24 samples: Use the SMARTer RNA Unique Dual Index Kit - 24U of the library preparation kit.ii.More than 24 samples: Use the SMARTer RNA Unique Dual Index Kit - 96U Set A or B.Note: The SMARTer RNA Unique Dual Index Kit - 96U Set A and B need to be ordered separately. More information on index sequences and pooling can be found in the SMARTer RNA Unique Dual Index Kit Protocol-at-a-Glance documentation.b.Using the SMART-Seq Total RNA Pico Input with UMIs (ZapR Mammalian): Use the Unique Dual Index Kits.Note: The Unique Dual Index Kits need to be ordered separately. More information on index sequences and pooling can be found in the Unique Dual Index Kits Protocol-at-a-Glance documentation. Select the correct UDIs, depending on the library preparation kit version used and the number of samples that need to be pooled.a.Using the SMARTer Stranded Total RNA-Seq Kit v3 – Pico Input Mammalian:i.For up to 24 samples: Use the SMARTer RNA Unique Dual Index Kit - 24U of the library preparation kit.ii.More than 24 samples: Use the SMARTer RNA Unique Dual Index Kit - 96U Set A or B.Note: The SMARTer RNA Unique Dual Index Kit - 96U Set A and B need to be ordered separately. More information on index sequences and pooling can be found in the SMARTer RNA Unique Dual Index Kit Protocol-at-a-Glance documentation.b.Using the SMART-Seq Total RNA Pico Input with UMIs (ZapR Mammalian): Use the Unique Dual Index Kits.Note: The Unique Dual Index Kits need to be ordered separately. More information on index sequences and pooling can be found in the Unique Dual Index Kits Protocol-at-a-Glance documentation. a.Using the SMARTer Stranded Total RNA-Seq Kit v3 – Pico Input Mammalian:i.For up to 24 samples: Use the SMARTer RNA Unique Dual Index Kit - 24U of the library preparation kit.ii.More than 24 samples: Use the SMARTer RNA Unique Dual Index Kit - 96U Set A or B.Note: The SMARTer RNA Unique Dual Index Kit - 96U Set A and B need to be ordered separately. More information on index sequences and pooling can be found in the SMARTer RNA Unique Dual Index Kit Protocol-at-a-Glance documentation. Using the SMARTer Stranded Total RNA-Seq Kit v3 – Pico Input Mammalian:i.For up to 24 samples: Use the SMARTer RNA Unique Dual Index Kit - 24U of the library preparation kit.ii.More than 24 samples: Use the SMARTer RNA Unique Dual Index Kit - 96U Set A or B.Note: The SMARTer RNA Unique Dual Index Kit - 96U Set A and B need to be ordered separately. More information on index sequences and pooling can be found in the SMARTer RNA Unique Dual Index Kit Protocol-at-a-Glance documentation. i.For up to 24 samples: Use the SMARTer RNA Unique Dual Index Kit - 24U of the library preparation kit. For up to 24 samples: Use the SMARTer RNA Unique Dual Index Kit - 24U of the library preparation kit. ii.More than 24 samples: Use the SMARTer RNA Unique Dual Index Kit - 96U Set A or B.Note: The SMARTer RNA Unique Dual Index Kit - 96U Set A and B need to be ordered separately. More information on index sequences and pooling can be found in the SMARTer RNA Unique Dual Index Kit Protocol-at-a-Glance documentation. More than 24 samples: Use the SMARTer RNA Unique Dual Index Kit - 96U Set A or B.Note: The SMARTer RNA Unique Dual Index Kit - 96U Set A and B need to be ordered separately. More information on index sequences and pooling can be found in the SMARTer RNA Unique Dual Index Kit Protocol-at-a-Glance documentation. Note: The SMARTer RNA Unique Dual Index Kit - 96U Set A and B need to be ordered separately. More information on index sequences and pooling can be found in the SMARTer RNA Unique Dual Index Kit Protocol-at-a-Glance documentation. b.Using the SMART-Seq Total RNA Pico Input with UMIs (ZapR Mammalian): Use the Unique Dual Index Kits.Note: The Unique Dual Index Kits need to be ordered separately. More information on index sequences and pooling can be found in the Unique Dual Index Kits Protocol-at-a-Glance documentation. Using the SMART-Seq Total RNA Pico Input with UMIs (ZapR Mammalian): Use the Unique Dual Index Kits.Note: The Unique Dual Index Kits need to be ordered separately. More information on index sequences and pooling can be found in the Unique Dual Index Kits Protocol-at-a-Glance documentation. Note: The Unique Dual Index Kits need to be ordered separately. More information on index sequences and pooling can be found in the Unique Dual Index Kits Protocol-at-a-Glance documentation. R-probes Timing: ∼10 min During ribosomal cDNA depletion (see Section depletion of ribosomal cDNA, step 44), library fragments originating from rRNA (18S and 28S) and mitochondrial rRNA (m12S and m16S) are cut by ZapR Enzyme in the presence of these R-Probes (mammalian-specific, included in both versions of the library preparation kit). These R-Probes target mammalian nuclear 28S, 18S, 5.8S, and 5S rRNA and human mitochondrial m16S and m12S rRNA sequences. 10.Aliquot the R-Probes at first use to limit the number of freeze-thaw cycles to 3 times. Aliquot the R-Probes at first use to limit the number of freeze-thaw cycles to 3 times. Tris Buffer Timing: ∼10 min During purification of the final RNA sequencing library, cDNA is eluted in Tris Buffer before library validation (see Section purification of the final RNA sequencing library, step 86). This Tris Buffer is included in both versions of the library preparation kit. 11.Aliquot the Tris Buffer into 12 wells of tube strips. Aliquot the Tris Buffer into 12 wells of tube strips. 12.Store the tube strips at 4 °C. Store the tube strips at 4 °C. Note: Do not mix up this Tris Buffer with the 1 M Tris-HCl pH 8.0 needed to prepare the Library Quantification Dilution (LQD) Buffer and Pooling Buffer (see Section materials and equipment and key resources table). KAPA Library Quantification Kit Timing: ∼1 h Libraries are quantified using the KAPA Library Quantification Kit and the LightCycler480 (see Section library quantification and pooling). The KAPA kit contains DNA Standards 1–6, Primer Mix, and KAPA SYBR FAST qPCR Master Mix. Reagents should be prepared as follows. 13.Thaw the KAPA SYBR FAST qPCR Master Mix and Primer Mix at room temperature (18°C–22°C). Thaw the KAPA SYBR FAST qPCR Master Mix and Primer Mix at room temperature (18°C–22°C). Note: The KAPA SYBR FAST qPCR Master Mix is light sensitive. Exposure to direct light for an extended period will result in a loss of fluorescent signal intensity. Protect the tube from light. 14.Vortex the Primer Mix tube and add 1 mL to the KAPA SYBR FAST qPCR Master Mix tube (5 mL) to obtain a total volume of 6 mL. Vortex the mixture. Vortex the Primer Mix tube and add 1 mL to the KAPA SYBR FAST qPCR Master Mix tube (5 mL) to obtain a total volume of 6 mL. Vortex the mixture. Note: To minimize freeze-thaw cycles, 1 mL aliquots of this master mix can be made in 1.5 mL tubes. 15.Pipette the DNA Standards 1–6 (80 μL) into different wells of an 8-well PCR tube strip, as well as 80 μL PCR-grade water. Pipette the DNA Standards 1–6 (80 μL) into different wells of an 8-well PCR tube strip, as well as 80 μL PCR-grade water. Note: This water will serve as a no-template control (NTC) sample for quantification. Volumes can be split across two tube strips to avoid freeze-thaw cycles. 16.Store master mix aliquots and DNA standards at −20 °C. Store master mix aliquots and DNA standards at −20 °C. Key resources table REAGENT or RESOURCESOURCEIDENTIFIERBiological samplesBlood plasmaHuman, murine, or rat donorN/AChemicals, peptides, and recombinant proteinsEthanol, abs. 100%, HPLC gradeAnalytiChem Belgium NVCat#CL00.0529.1000PCR-grade waterpxlenceCat#PXL-PGW-1000Invitrogen UltraPure GlycogenInvitrogenCat#10757844Sodium Acetate (3 M), pH 5.5, RNase-freeInvitrogenCat#AM97401 M Tris-HCl pH 8.0InvitrogenCat#15568025Tween20Sigma-AldrichCat#P1379Critical commercial assaysmiRNeasy Serum/Plasma KitQiagenCat#217184miRNeasy Serum/Plasma Advanced KitQiagenCat#217204QIAamp ccfDNA/RNA KitQiagenCat#55184HL-dsDNAseArcticZymesCat#70800-202Reaction buffer for gDNA removalArcticZymesCat#66001SMARTer Stranded Total RNA-Seq Kit v3 – Pico Input Mammalian kitTakara BioCat#634485-634488SMART-Seq Total RNA Pico Input with UMIs (ZapR Mammalian) kitTakara BioCat#634354-634356SMARTer RNA Unique Dual Index Kit - 96U Set A (for use with the SMARTer Stranded Total RNA-Seq Kit v3 – Pico Input Mammalian kit)Takara BioCat#634452SMARTer RNA Unique Dual Index Kit - 96U Set B (for use with the SMARTer Stranded Total RNA-Seq Kit v3 – Pico Input Mammalian kit)Takara BioCat#634457Unique Dual Index Kits (for use with SMART-Seq Total RNA Pico Input with UMIs (ZapR Mammalian) kitTakara BioCat#634752-634756AMPure XP beadsBeckman Coulter Life SciencesCat#A63881HS Small Fragment KitAgilentCat#DNF-477-0500KAPA Library Quantification KitRocheCat#079602980011× dsDNA HS Assay KitThermoFisher ScientificCat#33230Pippin Gel Cassette - 2% Agarose, dye-free, w/internal standards, Pippin Prep, 100 – 600 bpSopachemCat#CDF2010Deposited dataRaw and analyzed data of Decruyenaere et al.1The European Genome-Phenome Archive (EGA)Dataset EGA: EGAD00001011679OligonucleotidesSequin spike-in RNA controlsGarvan Institute of Medical Researchhttps://sequins.bio/ERCC RNA Spike-In MixThermoFisher ScientificCat#4456740Software and algorithmsUMI-toolsSmith et al.13https://github.com/CGATOxford/UMI-toolsSTARDobin et al.14https://github.com/alexdobin/STARSAMtoolsDanecek et al.15http://samtools.sourceforge.netHTSeqAnders et al.16https://github.com/htseq/htseqRSeQCWang et al.17https://rseqc.sourceforge.netFastQCAndrews (available online)18http://www.bioinformatics.babraham.ac.uk/projects/fastqc/RR Core Team19https://www.r-project.org/tidyverseWickham et al.20https://tidyverse.org/knitrXie Y et al.21https://cran.r-project.org/web/packages/knitr/index.htmlplotlyPlotly Technologies Inc.22https://plot.lyOtherBD Vacutainer Push Button Blood Collection SetBecton Dickinson and CompanyCat#367326Vacuette 9 mL, sodium citrate 3.2%MLSCat#KG455322Tube, 15 mL, PP, 17/120 mm, conical bottomGreiner Bio-One InternationalCat#188271LoBind microcentrifuge tubesEppendorfCat#022431021Centrifuge with swinging bucket rotor and appropriate adapters for blood collection tubes and 15 mL conical tubesEppendorfCentrifuge 5804 (Cat#5804 000.013) with rotor A-4-44 and adapters 5804 753.003 (for blood collection tubes) and 5804 755.006 (for 15 mL conical tubes)Cup Eppendorf Safe-Lock PCR Clean 1.5 mL and 2 mLEppendorfCat#A09000, A09001Eppendorf Tube with Snap Cap 5.0 mL - MicrotubeEppendorfCat#15138344Tubes, 0.2 mL, flat capThermoFisher ScientificCat#AB06208 Well PCR Tube Strip, With Attached CapsAzenta Life SciencesCat#4ti-0792FrameStar 96 Well Non-Skirted PCR Plates, Clear Wells, Clear FrameAzenta Life SciencesCat#4ti-0710/CMonochannel pipette P2, P10, P20, P100, P200 and P1000GilsonCat#FA10001M - FA10006MTripleA Filter Tips, Racked, Low Binding (tips for use with Gilson monochannel pipettes)WestburgCat#WB 5010 L, WB 5020 L, WB 5030 L, WB 5040 L, WB 5074 LEppendorf Research plus, 12-channel, 10–100 μL, yellow, variable volume (non-electronic)EppendorfCat#3125000044Eppendorf Research plus, 12-channel, 30–300 μL, orange, variable volume (non-electronic)EppendorfCat#3125000060Dualfilter T.I.P.S. GLP, in rack, PCR clean, sterile (tips for use with Eppendorf multichannel pipettes)EppendorfCat#A40221- A40223Pipet-Lite Multi Pipette L12-20XLS+ (non-electronic)Mettler ToledoCat#17013808E4 Multi Pipette Multi E12-20XLS+ (electronic)Mettler ToledoCat#17013798Filtertips ART 1–20 μL low retention (tips for use with multichannel pipettes Cat#17013808 and Cat#17013798)RaininCat#A26102Disposable reagent reservoir, 50 mL, sterileNovolabCat#A06354VIAFLO 96IntegraCat#6001, 6101, 6103, 6215, 6220Integra GripTips - Low Retention, Sterile, Filter (tips for use with VIAFLO 96)IntegraCat#6555, 6435150 mL Reagent Reservoir (reservoir for use with VIAFLO 96)IntegraCat#6301, 6302, 6337Mantis Liquid DispenserFormulatrixV3.3Mantis Chip – Silicone, HV (1 μL & 5 μL), RFID, PI. Pack of 12FormulatrixCat#233648High-Speed Multi Plate ShakerBiosanCat#BS-010216-A03, BS-010216-CKT100 Thermal CyclerBio-RadCat#186-1096Adhesive PCR Plate SealsABgeneCat#A00052Cooling unitsGreiner Bio-OneCat#978201 (for 8-well PCR tube strips and PCR tubes of 0.2 mL) and 978203 (for 1 mL and 2 mL tubes)Corning CoolRack XT PCR96, Holds 12 Strip Wells (cooling unit with SBS footprint for use with Mantis Liquid Dispenser and VIAFLO 96)CorningCat#432053Centrifuge for PCR platesEppendorfCat#5427 with rotor A-2-MTPDynaMag-96 Side MagnetInvitrogenCat#12331D96-Well Side Pull Bar Magnet PCR Separation PlatePermagen LabwareCat#MSP750Fragment Analyzer SystemAgilentCat#M5310AAFA 12-Capillary Array ShortAgilentCat#A2300-1250-3355LightCycler480RocheCat#05015243001384-well PCR platesThermoFisher ScientificCat#12771206Qubit 4 FluorometerThermoFisher ScientificCat#Q33238Pippin Prep SystemSage ScienceCat#PIP0001MicrocentrifugeNovolabCat#A40681ThermomixerNovolabCat#A25796 Materials and equipment Storage conditions for library preparation reagents Storage conditions for the library preparation reagents are summarized in Table 3, along with instructions for thawing and storing them during library preparation. Table 3Reagent storage conditions (during experiments)ReagentStorage (°C)How to thawHow to store during the experiment (upon thawing)First-strand cDNA synthesis (day 1)SMART UMI-TSO Mix v3a−80 °CCooling unitCooling unitSMART Pico Oligos Mix v3−20 °CRoom temperatureRoom temperature5× First-Strand Buffer−20 °CRoom temperatureRoom temperatureSMARTScribe II Reverse Transcriptaseb−20 °CCooling unitCooling unitRNase Inhibitor (40 U/μL)b−20 °CCooling unitCooling unitFirst PCR amplification (day 1)SeqAmp CB PCR Buffer (2×)−20°CRoom temperatureRoom temperaturePCR-grade water4 or −20°CRoom temperatureRoom temperatureUnique dual-indexed PCR primers−20°CRoom temperatureRoom temperatureSeqAMP DNA Polymeraseb−20°CCooling unitCooling unitPurification of the RNA sequencing library (day 2)AMPure XP beads4°CRoom temperatureRoom temperatureDepletion of ribosomal cDNA (day 2)R-Probesb,c−80°CCooling unitCooling unitZapR Buffer (10×)−20°CRoom temperatureRoom temperatureZapR Enzymeb,c−20°CCooling unitCooling unitSecond PCR amplification (day 2)SeqAmp CB PCR Buffer (2×)−20°CRoom temperatureRoom temperatureSeqAMP DNA Polymeraseb−20°CCooling unitCooling unitPCR2 Primers v3−20°CRoom temperatureRoom temperaturePurification of the final RNA sequencing library (day 2 or day 3)Tris Buffer4°CRoom temperatureRoom temperatureVortex and spin down all reagents before use.Room temperature is defined as the range between 18°C and 22°C. Cooling unit refers to the range between −18°C and −20°C.aDo not vortex the SMART-UMI-TSO Mix v3.bDo not vortex the SMARTScribe II Reverse Transcriptase, RNase Inhibitor (40 U/μL), SeqAMP DNA Polymerase, R-Probes, and ZapR Enzyme, but flick the tubes and spin down.cNomenclature of reagents is according to the SMART-Seq Total RNA Pico Input with UMIs (ZapR Mammalian) kit. In the v3 version of the kit, these products are indicated as R-Probes v3 and ZapR v3. Reagent storage conditions (during experiments) Vortex and spin down all reagents before use. Room temperature is defined as the range between 18°C and 22°C. Cooling unit refers to the range between −18°C and −20°C. Do not vortex the SMART-UMI-TSO Mix v3. Do not vortex the SMARTScribe II Reverse Transcriptase, RNase Inhibitor (40 U/μL), SeqAMP DNA Polymerase, R-Probes, and ZapR Enzyme, but flick the tubes and spin down. Nomenclature of reagents is according to the SMART-Seq Total RNA Pico Input with UMIs (ZapR Mammalian) kit. In the v3 version of the kit, these products are indicated as R-Probes v3 and ZapR v3. Thermal cycler programs for library preparation At multiple steps of the library preparation protocol, a T100 Thermal Cycler is used to incubate the samples according to different cycling protocols. We recommend pre-programming these cycling protocols (Tables 4, 5, 6, 7, 8, and 9) on the instrument before library preparation is started. Table 4Protocol steps 6 and 8: Thermal cycler program to fragment RNA with lid temperature set to 105 °C and volume set to 13 μLStepsTemperatureTimeCyclesPre-heat94 °C∞1 cycleIncubation94 °C2 min1 cycleHold12 °C∞1 cycleEstimated time: ± 3 min. Protocol steps 6 and 8: Thermal cycler program to fragment RNA with lid temperature set to 105 °C and volume set to 13 μL Estimated time: ± 3 min. Table 5Protocol steps 11 and 13: Thermal cycler program to synthesize first-strand cDNA with lid temperature set to 105 °C and volume set to 20 μLStepsTemperatureTimeCyclesPre-heat42°C∞1 cycleIncubation42°C90 or 180 mina1 cycleIncubation70°C10 min1 cycleHold12°C∞1 cycleEstimated time: ± 100 or 190 min.aWhen using the SMARTer Stranded Total RNA-Seq Kit v3 – Pico Input Mammalian, this incubation time is set to 180 min. When using the SMART-Seq Total RNA Pico Input with UMIs (ZapR Mammalian) kit, this incubation time is set to 90 min. Protocol steps 11 and 13: Thermal cycler program to synthesize first-strand cDNA with lid temperature set to 105 °C and volume set to 20 μL Estimated time: ± 100 or 190 min. When using the SMARTer Stranded Total RNA-Seq Kit v3 – Pico Input Mammalian, this incubation time is set to 180 min. When using the SMART-Seq Total RNA Pico Input with UMIs (ZapR Mammalian) kit, this incubation time is set to 90 min. Table 6Protocol steps 18 and 20: Thermal cycler program for the first RNA sequencing library amplification by PCR with lid temperature set to 105 °C and volume set to 50 μLStepsTemperatureTimeCyclesPre-heat94°C∞1 cycleIncubation94°C1 min1 cycleDenaturation98°C15 s5 cyclesAnnealing55°C15 sExtension68°C30 sIncubation68°C2 min1 cycleHold12°C∞1 cycleEstimated time: ± 15 min. Protocol steps 18 and 20: Thermal cycler program for the first RNA sequencing library amplification by PCR with lid temperature set to 105 °C and volume set to 50 μL Estimated time: ± 15 min. Table 7Protocol steps 43 and 44: Thermal cycler program for pre-heating the R-Probes with lid temperature set to 105°C and volume set to the corresponding volume of the R-Probes usedStepsTemperatureTimeCyclesPre-heat72°C∞1 cycleIncubation72°C2 min1 cycleHold12°C∞1 cycleEstimated time: ± 3 min. Protocol steps 43 and 44: Thermal cycler program for pre-heating the R-Probes with lid temperature set to 105°C and volume set to the corresponding volume of the R-Probes used Estimated time: ± 3 min. Table 8Protocol steps 55 and 59: Thermal cycler program for depletion of ribosomal cDNA with lid temperature set to 105 °C and volume set to 20 μLStepsTemperatureTimeCyclesPre-heat37°C∞1 cycleIncubation37°C60 min1 cycleIncubation72°C10 min1 cycleHold12°C∞1 cycleEstimated time: ± 70 min. Protocol steps 55 and 59: Thermal cycler program for depletion of ribosomal cDNA with lid temperature set to 105 °C and volume set to 20 μL Estimated time: ± 70 min. Table 9Protocol steps 61 and 66: Thermal cycler program for the second RNA sequencing library amplification by PCR with lid temperature set to 105 °C and volume set to 100 μLStepsTemperatureTimeCyclesPre-heat94°C∞1 cycleIncubation94°C1 min1 cycleDenaturation98°C15 s16 cyclesAnnealing55°C15 sExtension68°C30 sHold12°C∞1 cycleEstimated time: ± 35 min. Protocol steps 61 and 66: Thermal cycler program for the second RNA sequencing library amplification by PCR with lid temperature set to 105 °C and volume set to 100 μL Estimated time: ± 35 min. Sample dilution buffer for library quantification Libraries are quantified using the KAPA Library Quantification Kit and the LightCycler480. Libraries need to be diluted using the buffer prepared in the overview below (see Section library validation, step 97). Library Quantification Dilution (LQD) BufferReagentFinal concentrationAmount1 M Tris-HCl (pH 8)10 mM500 μLPCR-grade waterN/A49.48 mLTween20N/A25 μLTotalN/A50 mLStore at room temperature (18–22 °C) for up to 1 year. Library Quantification Dilution (LQD) Buffer Store at room temperature (18–22 °C) for up to 1 year. Sample pooling buffer for library pooling Libraries are equimolarly pooled upon library quantification (see Section library quantification and pooling, steps 106 to 109). Libraries need to be pooled using Pooling Buffer, which can be prepared by combining 500 μL 1 M Tris-HCl (pH 8; final concentration is 10 mM) and 49.5 mL PCR-grade water to obtain a total volume of 50 mL. Store the Pooling Buffer at room temperature (18–22 °C) for up to 3 years. Step-by-step method details Timing: The time required for each step in the protocol depends on the researcher’s experience, the number of samples included in the library preparation, and whether semi-automated pipetting is used. For up to 96 samples, a skilled lab technician can complete the entire library preparation protocol in 3–4 days, depending on the chosen pipetting method. An additional day should be scheduled if the optional library size selection step is performed (see sectionlibrary size selection). Note that the protocol includes defined safe stopping points; it cannot be paused at any other step. When performing the protocol for the first time, we recommend allowing sufficient time. First-strand cDNA synthesis Timing: Day 1 During this step, RNA is fragmented and first-strand cDNA synthesis is primed by the SMART Pico Oligos and uses the SMART UMI-TSO for template-switching at the 5′ end of the transcript (Figure 1A). Note: All steps of first-strand cDNA synthesis should be performed in a separate pre-PCR room to avoid contamination with PCR products. 1.Thaw the DNase-treated and spike-in-supplemented RNA eluate on a cooling unit. Flick the RNA eluate tube and spin down. Thaw the DNase-treated and spike-in-supplemented RNA eluate on a cooling unit. Flick the RNA eluate tube and spin down. 2.Pipette 8 μL of RNA sample into a 96-well PCR plate on a cooling unit.a.VIAFLO 96 option: transfer RNA samples in a 96-well PCR plate to a new 96-well PCR plate using the VIAFLO 96, with aspiration and dispense speeds set to 4. Pipette 8 μL of RNA sample into a 96-well PCR plate on a cooling unit.a.VIAFLO 96 option: transfer RNA samples in a 96-well PCR plate to a new 96-well PCR plate using the VIAFLO 96, with aspiration and dispense speeds set to 4. a.VIAFLO 96 option: transfer RNA samples in a 96-well PCR plate to a new 96-well PCR plate using the VIAFLO 96, with aspiration and dispense speeds set to 4. VIAFLO 96 option: transfer RNA samples in a 96-well PCR plate to a new 96-well PCR plate using the VIAFLO 96, with aspiration and dispense speeds set to 4. Note: A cooling unit with SBS footprint is required for use of the VIAFLO 96. Classical cooling units are incompatible with the equipment. 3.Seal the plate and spin down. Seal the plate and spin down. 4.Thaw the SMART UMI-TSO Mix v3 on a cooling unit (for use in step 12). Thaw the SMART UMI-TSO Mix v3 on a cooling unit (for use in step 12). 5.Thaw the SMART Pico Oligos Mix v3 and 5X First-Strand Buffer at room temperature (18°C–22°C). Thaw the SMART Pico Oligos Mix v3 and 5X First-Strand Buffer at room temperature (18°C–22°C). 6.Pre-heat a T100 Thermal Cycler according to the program indicated in Table 4. Pre-heat a T100 Thermal Cycler according to the program indicated in Table 4. 7.Prepare and add Fragmentation Master Mix (FMM; File S1).a.Pipette 1 μL of SMART Pico Oligos Mix v3 and 4 μL 5× First-Strand Buffer in a tube at room temperature (18°C–22°C).b.Vortex the mixture and spin down.c.Add 5 μL of FMM to the RNA sample on a cooling unit (new sample volume: 13 μL). Pipette up and down to mix.i.Multichannel pipetting option: When using an electronic multichannel pipette, set aspiration and dispense speed to 3, mix speed to 5, and mix volume to 11 μL.ii.Mantis option: Evaluate the time needed to add the FMM based on Table 2.Note: A cooling unit with an SBS footprint is required for use of the Mantis Liquid Dispenser. Classical cooling units are incompatible with the equipment.d.Seal the plate, spin down, and verify that there are no air bubbles. Prepare and add Fragmentation Master Mix (FMM; File S1).a.Pipette 1 μL of SMART Pico Oligos Mix v3 and 4 μL 5× First-Strand Buffer in a tube at room temperature (18°C–22°C).b.Vortex the mixture and spin down.c.Add 5 μL of FMM to the RNA sample on a cooling unit (new sample volume: 13 μL). Pipette up and down to mix.i.Multichannel pipetting option: When using an electronic multichannel pipette, set aspiration and dispense speed to 3, mix speed to 5, and mix volume to 11 μL.ii.Mantis option: Evaluate the time needed to add the FMM based on Table 2.Note: A cooling unit with an SBS footprint is required for use of the Mantis Liquid Dispenser. Classical cooling units are incompatible with the equipment.d.Seal the plate, spin down, and verify that there are no air bubbles. a.Pipette 1 μL of SMART Pico Oligos Mix v3 and 4 μL 5× First-Strand Buffer in a tube at room temperature (18°C–22°C). Pipette 1 μL of SMART Pico Oligos Mix v3 and 4 μL 5× First-Strand Buffer in a tube at room temperature (18°C–22°C). b.Vortex the mixture and spin down. Vortex the mixture and spin down. c.Add 5 μL of FMM to the RNA sample on a cooling unit (new sample volume: 13 μL). Pipette up and down to mix.i.Multichannel pipetting option: When using an electronic multichannel pipette, set aspiration and dispense speed to 3, mix speed to 5, and mix volume to 11 μL.ii.Mantis option: Evaluate the time needed to add the FMM based on Table 2.Note: A cooling unit with an SBS footprint is required for use of the Mantis Liquid Dispenser. Classical cooling units are incompatible with the equipment. Add 5 μL of FMM to the RNA sample on a cooling unit (new sample volume: 13 μL). Pipette up and down to mix.i.Multichannel pipetting option: When using an electronic multichannel pipette, set aspiration and dispense speed to 3, mix speed to 5, and mix volume to 11 μL.ii.Mantis option: Evaluate the time needed to add the FMM based on Table 2.Note: A cooling unit with an SBS footprint is required for use of the Mantis Liquid Dispenser. Classical cooling units are incompatible with the equipment. i.Multichannel pipetting option: When using an electronic multichannel pipette, set aspiration and dispense speed to 3, mix speed to 5, and mix volume to 11 μL. Multichannel pipetting option: When using an electronic multichannel pipette, set aspiration and dispense speed to 3, mix speed to 5, and mix volume to 11 μL. ii.Mantis option: Evaluate the time needed to add the FMM based on Table 2.Note: A cooling unit with an SBS footprint is required for use of the Mantis Liquid Dispenser. Classical cooling units are incompatible with the equipment. Mantis option: Evaluate the time needed to add the FMM based on Table 2.Note: A cooling unit with an SBS footprint is required for use of the Mantis Liquid Dispenser. Classical cooling units are incompatible with the equipment. Note: A cooling unit with an SBS footprint is required for use of the Mantis Liquid Dispenser. Classical cooling units are incompatible with the equipment. d.Seal the plate, spin down, and verify that there are no air bubbles. Seal the plate, spin down, and verify that there are no air bubbles. 8.Place the 96-well PCR plate on a pre-programmed T100 Thermal Cycler and incubate according to the program described in Table 4. Place the 96-well PCR plate on a pre-programmed T100 Thermal Cycler and incubate according to the program described in Table 4. 9.Meanwhile, place the SMARTScribe II Reverse Transcriptase and RNase Inhibitor on a cooling unit (for use in step 12). Meanwhile, place the SMARTScribe II Reverse Transcriptase and RNase Inhibitor on a cooling unit (for use in step 12). 10.Ideally, place the plate from the thermal cycler on a cooling unit for 2 min once the second step in Table 4 is completed. At the latest, move the plate from the thermal cycler to a cooling unit for 2 min when the thermal cycler reaches 12°C. Ideally, place the plate from the thermal cycler on a cooling unit for 2 min once the second step in Table 4 is completed. At the latest, move the plate from the thermal cycler to a cooling unit for 2 min when the thermal cycler reaches 12°C. 11.Pre-heat a thermal cycler according to the program indicated in Table 5. Select the appropriate incubation time, depending on the library preparation kit version that is used. Pre-heat a thermal cycler according to the program indicated in Table 5. Select the appropriate incubation time, depending on the library preparation kit version that is used. 12.Prepare and add First-Strand Master Mix (FSMM; File S1). Prepare and add First-Strand Master Mix (FSMM; File S1). a.Pipette 4.5 μL of SMART UMI-TSO Mix v3, 0.5 μL of RNase inhibitor, and 2 μL of SMARTScribe II Reverse Transcriptase into a tube on a cooling unit.Note: The SMART UMI-TSO Mix v3 is very viscous. Therefore, slowly pipette all components into the mixture. Only when all components have been added, pipette up and down 10 times to homogenize the FSMM. Pipette 4.5 μL of SMART UMI-TSO Mix v3, 0.5 μL of RNase inhibitor, and 2 μL of SMARTScribe II Reverse Transcriptase into a tube on a cooling unit.Note: The SMART UMI-TSO Mix v3 is very viscous. Therefore, slowly pipette all components into the mixture. Only when all components have been added, pipette up and down 10 times to homogenize the FSMM. Note: The SMART UMI-TSO Mix v3 is very viscous. Therefore, slowly pipette all components into the mixture. Only when all components have been added, pipette up and down 10 times to homogenize the FSMM. b.Spin down the 96-well PCR plate. Spin down the 96-well PCR plate. c.Add 7 μL of the FSMM to the sample well (new sample volume: 20 μL). Pipette up and down to mix.i.Multichannel pipetting option: When using an electronic multichannel pipette, set aspiration and dispense speed to 2, mix speed to 6, and mix volume to 17 μL.ii.Mantis option: Evaluate the time needed to add the FSMM based on Table 2. Add 7 μL of the FSMM to the sample well (new sample volume: 20 μL). Pipette up and down to mix.i.Multichannel pipetting option: When using an electronic multichannel pipette, set aspiration and dispense speed to 2, mix speed to 6, and mix volume to 17 μL.ii.Mantis option: Evaluate the time needed to add the FSMM based on Table 2. i.Multichannel pipetting option: When using an electronic multichannel pipette, set aspiration and dispense speed to 2, mix speed to 6, and mix volume to 17 μL. Multichannel pipetting option: When using an electronic multichannel pipette, set aspiration and dispense speed to 2, mix speed to 6, and mix volume to 17 μL. ii.Mantis option: Evaluate the time needed to add the FSMM based on Table 2. Mantis option: Evaluate the time needed to add the FSMM based on Table 2. d.Seal the plate and spin down. Seal the plate and spin down. 13.Place the 96-well PCR plate on a pre-programmed thermal cycler and incubate according to the program described in Table 5. Place the 96-well PCR plate on a pre-programmed thermal cycler and incubate according to the program described in Table 5. Note: Leave the plate in the thermal cycler at 12°C until the next step. Note: Meanwhile, thaw the unique dual-indexed PCR primers (UDIs) and SeqAmp CB PCR Buffer (2×) at room temperature (18–22 °C; for use in Section first PCR amplification, step 15 and 19, respectively). The SeqAmp CB PCR Buffer (2×) may remain in a liquid state at −20 °C. In that case, place the buffer at 4 °C until the UDIs are thawed. Then, place the tube at room temperature (18–22 °C) to equilibrate the buffer for 10–20 min. First PCR amplification Timing: Day 1 The first-strand cDNA is amplified into RNA sequencing libraries using SeqAmp DNA Polymerase, and Illumina adapters and indexes are incorporated via the UDIs from the Unique Dual Index Kits (Figure 1B). Note: All steps prior to PCR amplification on the thermal cycler (step 20) should be performed in a separate pre-PCR room to prevent contamination with PCR products. 14.Upon incubation in the thermal cycler, spin down the 96-well PCR plate. Upon incubation in the thermal cycler, spin down the 96-well PCR plate. 15.Add 2 μL of the appropriate UDI to each sample well (new sample volume: 22 μL). Add 2 μL of the appropriate UDI to each sample well (new sample volume: 22 μL). Note: Since the UDIs are provided in 96-well plates by Takara Bio, they can be added using multichannel pipetting or using the VIAFLO96 with aspiration and dispense speeds set to 4. 16.Seal the plate and spin down. Seal the plate and spin down. 17.Place the SeqAmp DNA Polymerase on a cooling unit. Place the SeqAmp DNA Polymerase on a cooling unit. 18.Pre-heat a T100 Thermal Cycler according to the program indicated in Table 6. Pre-heat a T100 Thermal Cycler according to the program indicated in Table 6. 19.Prepare and add PCR1 Master mix (P1MM; File S1).a.Pipette 2 μL of PCR-grade water, 25 μL of SeqAmp CB PCR Buffer (2X), and 1 μL of SeqAmp DNA Polymerase into a tube on a cooling unit.b.Pipette up and down to homogenize the mixture and spin down.c.Add 28 μL of P1MM to each sample well on a cooling unit (new sample volume: 50 μL). Pipette up and down to mix.i.Multichannel pipetting option: Use a multichannel pipette to add the P1MM to the library preparation plate.ii.Mantis option: Evaluate the time needed to add the P1MM based on Table 2.d.Seal the plate and spin down. Prepare and add PCR1 Master mix (P1MM; File S1).a.Pipette 2 μL of PCR-grade water, 25 μL of SeqAmp CB PCR Buffer (2X), and 1 μL of SeqAmp DNA Polymerase into a tube on a cooling unit.b.Pipette up and down to homogenize the mixture and spin down.c.Add 28 μL of P1MM to each sample well on a cooling unit (new sample volume: 50 μL). Pipette up and down to mix.i.Multichannel pipetting option: Use a multichannel pipette to add the P1MM to the library preparation plate.ii.Mantis option: Evaluate the time needed to add the P1MM based on Table 2.d.Seal the plate and spin down. a.Pipette 2 μL of PCR-grade water, 25 μL of SeqAmp CB PCR Buffer (2X), and 1 μL of SeqAmp DNA Polymerase into a tube on a cooling unit. Pipette 2 μL of PCR-grade water, 25 μL of SeqAmp CB PCR Buffer (2X), and 1 μL of SeqAmp DNA Polymerase into a tube on a cooling unit. b.Pipette up and down to homogenize the mixture and spin down. Pipette up and down to homogenize the mixture and spin down. c.Add 28 μL of P1MM to each sample well on a cooling unit (new sample volume: 50 μL). Pipette up and down to mix.i.Multichannel pipetting option: Use a multichannel pipette to add the P1MM to the library preparation plate.ii.Mantis option: Evaluate the time needed to add the P1MM based on Table 2. Add 28 μL of P1MM to each sample well on a cooling unit (new sample volume: 50 μL). Pipette up and down to mix.i.Multichannel pipetting option: Use a multichannel pipette to add the P1MM to the library preparation plate.ii.Mantis option: Evaluate the time needed to add the P1MM based on Table 2. i.Multichannel pipetting option: Use a multichannel pipette to add the P1MM to the library preparation plate. Multichannel pipetting option: Use a multichannel pipette to add the P1MM to the library preparation plate. ii.Mantis option: Evaluate the time needed to add the P1MM based on Table 2. Mantis option: Evaluate the time needed to add the P1MM based on Table 2. d.Seal the plate and spin down. Seal the plate and spin down. 20.Place the 96-well PCR plate on a pre-programmed thermal cycler and incubate according to the program described in Table 6. Place the 96-well PCR plate on a pre-programmed thermal cycler and incubate according to the program described in Table 6. Pause point: The library preparation protocol can be paused here safely. Seal the plate and store at −20°C for up to 2 weeks. Purification of the RNA sequencing library Timing: Day 2 The amplified RNA sequencing library is purified by immobilizing it onto AMPure XP beads. The beads are then washed with 80% ethanol, and the cDNA is eluted with PCR-grade water before ribosomal cDNA depletion (Figure 1B). Note: Purification of the RNA sequencing library should be performed in a post-PCR room. 21.Bring AMPure XP beads to room temperature (18–22 °C) for at least 30 min. Bring AMPure XP beads to room temperature (18–22 °C) for at least 30 min. 22.Thaw the 96-well PCR plate at room temperature (18–22 °C) and spin down. Thaw the 96-well PCR plate at room temperature (18–22 °C) and spin down. 23.Vortex the AMPure XP beads until they are well dispersed. Vortex the AMPure XP beads until they are well dispersed. 24.Add 40 μL of well-dispersed AMPure XP beads to the sample well (new sample volume: 90 μL).a.Multichannel pipetting option:i.Pour the beads into a disposable reagent reservoir.ii.Add 40 μL of beads to the library preparation plate.b.VIAFLO 96 option:i.Pour the beads into a VIAFLO 96-compatible reagent reservoir.ii.Add 40 μL of beads to the library preparation plate using the VIAFLO 96, with aspiration and dispense speeds set to 1. Add 40 μL of well-dispersed AMPure XP beads to the sample well (new sample volume: 90 μL).a.Multichannel pipetting option:i.Pour the beads into a disposable reagent reservoir.ii.Add 40 μL of beads to the library preparation plate.b.VIAFLO 96 option:i.Pour the beads into a VIAFLO 96-compatible reagent reservoir.ii.Add 40 μL of beads to the library preparation plate using the VIAFLO 96, with aspiration and dispense speeds set to 1. a.Multichannel pipetting option:i.Pour the beads into a disposable reagent reservoir.ii.Add 40 μL of beads to the library preparation plate. Multichannel pipetting option:i.Pour the beads into a disposable reagent reservoir.ii.Add 40 μL of beads to the library preparation plate. i.Pour the beads into a disposable reagent reservoir. Pour the beads into a disposable reagent reservoir. ii.Add 40 μL of beads to the library preparation plate. Add 40 μL of beads to the library preparation plate. b.VIAFLO 96 option:i.Pour the beads into a VIAFLO 96-compatible reagent reservoir.ii.Add 40 μL of beads to the library preparation plate using the VIAFLO 96, with aspiration and dispense speeds set to 1. VIAFLO 96 option:i.Pour the beads into a VIAFLO 96-compatible reagent reservoir.ii.Add 40 μL of beads to the library preparation plate using the VIAFLO 96, with aspiration and dispense speeds set to 1. i.Pour the beads into a VIAFLO 96-compatible reagent reservoir. Pour the beads into a VIAFLO 96-compatible reagent reservoir. ii.Add 40 μL of beads to the library preparation plate using the VIAFLO 96, with aspiration and dispense speeds set to 1. Add 40 μL of beads to the library preparation plate using the VIAFLO 96, with aspiration and dispense speeds set to 1. 25.Seal the plate and pulse vortex for 5 s. Seal the plate and pulse vortex for 5 s. 26.Incubate the plate at room temperature (18–22°C) for 8 min to let the DNA bind to the beads. Incubate the plate at room temperature (18–22°C) for 8 min to let the DNA bind to the beads. Note: Meanwhile, also prepare two fresh 96-well PCR plates with well-dispersed AMPure XP beads when multichannel pipetting or the VIAFLO 96 was used in step 24. The first plate is for use in step 39 and should contain 40 μL beads in each sample well. The second plate is for use in Section purification of the final RNA sequencing library, step 82 and should contain 20 μL beads in each sample well. Seal the plates and store at 4 °C. Note: Meanwhile, thaw the R-Probes on a cooling unit (for use in Section depletion of ribosomal cDNA, step 44), thaw the ZapR Buffer at room temperature (18–22°C; for use in Section depletion of ribosomal cDNA, step 48), and bring PCR-grade water to room temperature (18–22 °C). 27.Spin down the plate for 1 min at 280 g. Spin down the plate for 1 min at 280 g. 28.Place the plate on a magnetic stand at room temperature (18–22 °C) for 5 min or longer, until the solution is completely clear. Place the plate on a magnetic stand at room temperature (18–22 °C) for 5 min or longer, until the solution is completely clear. Note: When using the VIAFLO 96 for subsequent bead clean-ups (i.e., steps 30, 35, Section depletion of ribosomal cDNA, step 50, and Section purification of the final RNA sequencing library, step 75,77 and 85), make sure to use a VIAFLO 96 compatible magnetic stand from step 28 onwards, for example, the 96-Well Side Pull Bar Magnet PCR Separation. Do not transfer the library preparation plate from one magnetic stand to another. 29.While the plate is on the magnetic stand, remove 80 μL of supernatant without disturbing the beads. While the plate is on the magnetic stand, remove 80 μL of supernatant without disturbing the beads. Note: This step can also be performed using multichannel pipetting. Make sure that no beads are pipetted out (see Section problem 1 and potential solution in troubleshooting). 30.Keep the plate on the magnetic stand. Add 200 μL of freshly prepared 80% ethanol to each sample well, without disturbing the beads. Wait 30 s, then carefully remove the supernatant.a.Multichannel pipetting option:i.Pour the ethanol into a disposable reagent reservoir.ii.Add 200 μL of ethanol to the library preparation plate.iii.Remove the supernatant.b.VIAFLO 96 option:i.Pour the ethanol into a VIAFLO 96-compatible reagent reservoir.ii.Add 200 μL of ethanol to the library preparation plate using the VIAFLO 96, with aspiration speed 10 and dispense speed 7.iii.Remove the supernatant, using aspiration speed 3 and dispense speed 7. Keep the plate on the magnetic stand. Add 200 μL of freshly prepared 80% ethanol to each sample well, without disturbing the beads. Wait 30 s, then carefully remove the supernatant.a.Multichannel pipetting option:i.Pour the ethanol into a disposable reagent reservoir.ii.Add 200 μL of ethanol to the library preparation plate.iii.Remove the supernatant.b.VIAFLO 96 option:i.Pour the ethanol into a VIAFLO 96-compatible reagent reservoir.ii.Add 200 μL of ethanol to the library preparation plate using the VIAFLO 96, with aspiration speed 10 and dispense speed 7.iii.Remove the supernatant, using aspiration speed 3 and dispense speed 7. a.Multichannel pipetting option:i.Pour the ethanol into a disposable reagent reservoir.ii.Add 200 μL of ethanol to the library preparation plate.iii.Remove the supernatant. Multichannel pipetting option:i.Pour the ethanol into a disposable reagent reservoir.ii.Add 200 μL of ethanol to the library preparation plate.iii.Remove the supernatant. i.Pour the ethanol into a disposable reagent reservoir. Pour the ethanol into a disposable reagent reservoir. ii.Add 200 μL of ethanol to the library preparation plate. Add 200 μL of ethanol to the library preparation plate. iii.Remove the supernatant. Remove the supernatant. b.VIAFLO 96 option:i.Pour the ethanol into a VIAFLO 96-compatible reagent reservoir.ii.Add 200 μL of ethanol to the library preparation plate using the VIAFLO 96, with aspiration speed 10 and dispense speed 7.iii.Remove the supernatant, using aspiration speed 3 and dispense speed 7. VIAFLO 96 option:i.Pour the ethanol into a VIAFLO 96-compatible reagent reservoir.ii.Add 200 μL of ethanol to the library preparation plate using the VIAFLO 96, with aspiration speed 10 and dispense speed 7.iii.Remove the supernatant, using aspiration speed 3 and dispense speed 7. i.Pour the ethanol into a VIAFLO 96-compatible reagent reservoir. Pour the ethanol into a VIAFLO 96-compatible reagent reservoir. ii.Add 200 μL of ethanol to the library preparation plate using the VIAFLO 96, with aspiration speed 10 and dispense speed 7. Add 200 μL of ethanol to the library preparation plate using the VIAFLO 96, with aspiration speed 10 and dispense speed 7. iii.Remove the supernatant, using aspiration speed 3 and dispense speed 7. Remove the supernatant, using aspiration speed 3 and dispense speed 7. Note: Make sure that no beads are pipetted out. 31.Repeat step 30 once. Repeat step 30 once. 32.Seal the plate and spin it for 1 min at 280 g to collect the remaining ethanol at the bottom of each tube. Seal the plate and spin it for 1 min at 280 g to collect the remaining ethanol at the bottom of each tube. 33.Place the plate at the magnetic stand for 30 s. Remove all the remaining ethanol. Place the plate at the magnetic stand for 30 s. Remove all the remaining ethanol. Note: This step can also be performed using multichannel pipetting. Make sure that no beads are pipetted out. 34.Keep the plate on the magnetic stand. Let the plate rest open at room temperature (18–22 °C) for 3–5 min until the pellet appears dry. Check the pellet frequently and proceed to the next step once the beads are dry. Keep the plate on the magnetic stand. Let the plate rest open at room temperature (18–22 °C) for 3–5 min until the pellet appears dry. Check the pellet frequently and proceed to the next step once the beads are dry. Note: If the pellet is overdried, there will be cracks in the pellet. If this occurs, the DNA may not elute well from the beads, resulting in reduced recovery. 35.Keep the plate on the magnetic stand. Add 52 μL of PCR-grade water to cover the beads (new sample volume: 52 μL).a.Multichannel pipetting option:i.Pour PCR-grade water into a disposable reagent reservoir.ii.Add 52 μL of water to the library preparation plate.b.VIAFLO 96 option:i.Pour PCR-grade water into a VIAFLO 96-compatible reagent reservoir.ii.Add 52 μL of water to the library preparation plate using the VIAFLO 96, with aspiration speed set to 3 and dispense speed set to 7. Keep the plate on the magnetic stand. Add 52 μL of PCR-grade water to cover the beads (new sample volume: 52 μL).a.Multichannel pipetting option:i.Pour PCR-grade water into a disposable reagent reservoir.ii.Add 52 μL of water to the library preparation plate.b.VIAFLO 96 option:i.Pour PCR-grade water into a VIAFLO 96-compatible reagent reservoir.ii.Add 52 μL of water to the library preparation plate using the VIAFLO 96, with aspiration speed set to 3 and dispense speed set to 7. a.Multichannel pipetting option:i.Pour PCR-grade water into a disposable reagent reservoir.ii.Add 52 μL of water to the library preparation plate. Multichannel pipetting option:i.Pour PCR-grade water into a disposable reagent reservoir.ii.Add 52 μL of water to the library preparation plate. i.Pour PCR-grade water into a disposable reagent reservoir. Pour PCR-grade water into a disposable reagent reservoir. ii.Add 52 μL of water to the library preparation plate. Add 52 μL of water to the library preparation plate. b.VIAFLO 96 option:i.Pour PCR-grade water into a VIAFLO 96-compatible reagent reservoir.ii.Add 52 μL of water to the library preparation plate using the VIAFLO 96, with aspiration speed set to 3 and dispense speed set to 7. VIAFLO 96 option:i.Pour PCR-grade water into a VIAFLO 96-compatible reagent reservoir.ii.Add 52 μL of water to the library preparation plate using the VIAFLO 96, with aspiration speed set to 3 and dispense speed set to 7. i.Pour PCR-grade water into a VIAFLO 96-compatible reagent reservoir. Pour PCR-grade water into a VIAFLO 96-compatible reagent reservoir. ii.Add 52 μL of water to the library preparation plate using the VIAFLO 96, with aspiration speed set to 3 and dispense speed set to 7. Add 52 μL of water to the library preparation plate using the VIAFLO 96, with aspiration speed set to 3 and dispense speed set to 7. 36.Seal the plate, remove it from the magnetic stand, and flick the wells until the beads are resuspended. Seal the plate, remove it from the magnetic stand, and flick the wells until the beads are resuspended. 37.Incubate the plate at room temperature (18–22°C) for 5 min to rehydrate. Incubate the plate at room temperature (18–22°C) for 5 min to rehydrate. 38.Spin down the plate, remove the seal, and place it on the magnetic stand for 2 min or longer, until the solution is completely clear. Spin down the plate, remove the seal, and place it on the magnetic stand for 2 min or longer, until the solution is completely clear. 39.Keep the plate on the magnetic stand. Transfer 50 μL of clear supernatant containing the purified RNA sequencing library to a fresh 96-well PCR plate (see Section problem 1 and potential solution in troubleshooting; new sample volume: 50 μL). Keep the plate on the magnetic stand. Transfer 50 μL of clear supernatant containing the purified RNA sequencing library to a fresh 96-well PCR plate (see Section problem 1 and potential solution in troubleshooting; new sample volume: 50 μL). Note: This step can also be performed using multichannel pipetting. Make sure that no beads are pipetted out. Note: When a fresh 96-well PCR plate with beads was prepared in step 24, transfer the clear supernatant directly to this plate, and skip step 40. 40.Add 40 μL well-dispersed AMPure XP beads to the sample well (new sample volume: 90 μL).a.Multichannel pipetting option:i.Pour the beads into a disposable reagent reservoir.ii.Add 40 μL of beads to the library preparation plate.b.VIAFLO 96 option:i.Pour the beads into a VIAFLO 96-compatible reagent reservoir.ii.Add 40 μL of beads to the library preparation plate using the VIAFLO 96, with aspiration and dispense speed set to 1. Add 40 μL well-dispersed AMPure XP beads to the sample well (new sample volume: 90 μL).a.Multichannel pipetting option:i.Pour the beads into a disposable reagent reservoir.ii.Add 40 μL of beads to the library preparation plate.b.VIAFLO 96 option:i.Pour the beads into a VIAFLO 96-compatible reagent reservoir.ii.Add 40 μL of beads to the library preparation plate using the VIAFLO 96, with aspiration and dispense speed set to 1. a.Multichannel pipetting option:i.Pour the beads into a disposable reagent reservoir.ii.Add 40 μL of beads to the library preparation plate. Multichannel pipetting option:i.Pour the beads into a disposable reagent reservoir.ii.Add 40 μL of beads to the library preparation plate. i.Pour the beads into a disposable reagent reservoir. Pour the beads into a disposable reagent reservoir. ii.Add 40 μL of beads to the library preparation plate. Add 40 μL of beads to the library preparation plate. b.VIAFLO 96 option:i.Pour the beads into a VIAFLO 96-compatible reagent reservoir.ii.Add 40 μL of beads to the library preparation plate using the VIAFLO 96, with aspiration and dispense speed set to 1. VIAFLO 96 option:i.Pour the beads into a VIAFLO 96-compatible reagent reservoir.ii.Add 40 μL of beads to the library preparation plate using the VIAFLO 96, with aspiration and dispense speed set to 1. i.Pour the beads into a VIAFLO 96-compatible reagent reservoir. Pour the beads into a VIAFLO 96-compatible reagent reservoir. ii.Add 40 μL of beads to the library preparation plate using the VIAFLO 96, with aspiration and dispense speed set to 1. Add 40 μL of beads to the library preparation plate using the VIAFLO 96, with aspiration and dispense speed set to 1. 41.Seal the plate and pulse vortex for 5 s. Seal the plate and pulse vortex for 5 s. 42.Incubate the plate at room temperature (18–22°C) for 8 min to let the DNA bind to the beads. Incubate the plate at room temperature (18–22°C) for 8 min to let the DNA bind to the beads. Depletion of ribosomal cDNA Timing: Day 2 Library fragments originating from rRNA (18S and 28S) and mitochondrial rRNA (m12S and m16S) are cut by ZapR Enzyme in the presence of R-Probes (mammalian-specific). These R-Probes target mammalian nuclear 28S, 18S, 5.8S, and 5S rRNA and human mitochondrial m16S and m12S rRNA sequences. Non-human mitochondrial rRNA sequences will not be removed (Figure 1C). Note: Steps 43–44 and steps 47–48 should be performed in a separate, pre-PCR room to avoid contamination with PCR products. All other steps should be performed in a post-PCR room. 43.Pre-heat a thermal cycler according to the program indicated in Table 7. Pre-heat a thermal cycler according to the program indicated in Table 7. 44.Prepare R-Probes.a.Pipette a sufficient volume of R-Probes for the number of reactions to be performed into a PCR tube on a cooling unit. Use 1.5 μL per reaction, and add an extra 1 to 2 μL to the total volume to ensure sufficient volume for transfer in step 48.b.Spin down, place the tube into the pre-programmed thermal cycler, and incubate according to the program described in Table 7. Prepare R-Probes.a.Pipette a sufficient volume of R-Probes for the number of reactions to be performed into a PCR tube on a cooling unit. Use 1.5 μL per reaction, and add an extra 1 to 2 μL to the total volume to ensure sufficient volume for transfer in step 48.b.Spin down, place the tube into the pre-programmed thermal cycler, and incubate according to the program described in Table 7. a.Pipette a sufficient volume of R-Probes for the number of reactions to be performed into a PCR tube on a cooling unit. Use 1.5 μL per reaction, and add an extra 1 to 2 μL to the total volume to ensure sufficient volume for transfer in step 48. Pipette a sufficient volume of R-Probes for the number of reactions to be performed into a PCR tube on a cooling unit. Use 1.5 μL per reaction, and add an extra 1 to 2 μL to the total volume to ensure sufficient volume for transfer in step 48. b.Spin down, place the tube into the pre-programmed thermal cycler, and incubate according to the program described in Table 7. Spin down, place the tube into the pre-programmed thermal cycler, and incubate according to the program described in Table 7. Note: Leave the R-Probes in the thermal cycler at 12°C for at least 2 min, but for no more than 10–15 min, before using it to make the ZapR Master Mix (step 48). Note: Immediately return the remaining unused R-Probes to −80°C for storage. 45.Upon incubation (step 42), spin the 96-well PCR plate at 280 g for 1 min. Upon incubation (step 42), spin the 96-well PCR plate at 280 g for 1 min. 46.Place the plate on a magnetic stand at room temperature (18–22 °C) for 5 min or longer, until the solution is completely clear. Place the plate on a magnetic stand at room temperature (18–22 °C) for 5 min or longer, until the solution is completely clear. 47.Place ZapR Enzyme on a cooling unit. Place ZapR Enzyme on a cooling unit. 48.Prepare ZapR Master Mix (ZMM; File S1). Select option a or b, depending on the library preparation kit version used.a.Using the SMARTer Stranded Total RNA-Seq Kit v3 – Pico Input Mammalian: Pipette 16.80 μL of PCR-grade water, 2.20 μL of 10× ZapR Buffer, 1.5 μL of ZapR v3, and 1.5 μL of R-Probes v3 in a tube at room temperature (18–22°C).b.Using the SMART-Seq Total RNA Pico Input with UMIs (ZapR Mammalian) kit: Pipette 15.50 μL of PCR-grade water, 2.20 μL of 10× ZapR Buffer, 2.80 μL of ZapR Enzyme, and 1.50 μL of R-Probes in a tube at room temperature (18–22°C). Prepare ZapR Master Mix (ZMM; File S1). Select option a or b, depending on the library preparation kit version used.a.Using the SMARTer Stranded Total RNA-Seq Kit v3 – Pico Input Mammalian: Pipette 16.80 μL of PCR-grade water, 2.20 μL of 10× ZapR Buffer, 1.5 μL of ZapR v3, and 1.5 μL of R-Probes v3 in a tube at room temperature (18–22°C).b.Using the SMART-Seq Total RNA Pico Input with UMIs (ZapR Mammalian) kit: Pipette 15.50 μL of PCR-grade water, 2.20 μL of 10× ZapR Buffer, 2.80 μL of ZapR Enzyme, and 1.50 μL of R-Probes in a tube at room temperature (18–22°C). a.Using the SMARTer Stranded Total RNA-Seq Kit v3 – Pico Input Mammalian: Pipette 16.80 μL of PCR-grade water, 2.20 μL of 10× ZapR Buffer, 1.5 μL of ZapR v3, and 1.5 μL of R-Probes v3 in a tube at room temperature (18–22°C). Using the SMARTer Stranded Total RNA-Seq Kit v3 – Pico Input Mammalian: Pipette 16.80 μL of PCR-grade water, 2.20 μL of 10× ZapR Buffer, 1.5 μL of ZapR v3, and 1.5 μL of R-Probes v3 in a tube at room temperature (18–22°C). b.Using the SMART-Seq Total RNA Pico Input with UMIs (ZapR Mammalian) kit: Pipette 15.50 μL of PCR-grade water, 2.20 μL of 10× ZapR Buffer, 2.80 μL of ZapR Enzyme, and 1.50 μL of R-Probes in a tube at room temperature (18–22°C). Using the SMART-Seq Total RNA Pico Input with UMIs (ZapR Mammalian) kit: Pipette 15.50 μL of PCR-grade water, 2.20 μL of 10× ZapR Buffer, 2.80 μL of ZapR Enzyme, and 1.50 μL of R-Probes in a tube at room temperature (18–22°C). Note: The ZapR Enzyme is very viscous. Therefore, slowly pipette all components into the mixture in the same order as listed above. Ensure that the preheated and chilled R-Probes are added last. Only when all ZMM components have been added, pipette up and down 10 times to homogenize the mix and spin down. Note: Immediately return the ZapR Enzyme to −20°C after use. Note: When using the multichannel option to add the ZMM to the library preparation plate in step 52, aliquot the ZMM into strip(s). 49.While the plate is on the magnetic stand, remove 80 μL of supernatant without disturbing the beads. While the plate is on the magnetic stand, remove 80 μL of supernatant without disturbing the beads. Note: This step can also be performed using multichannel pipetting. Make sure that no beads are pipetted out (see Section problem 1 and potential solution in troubleshooting). 50.Repeat Section purification of the RNA sequencing library, step 30 to 33. Repeat Section purification of the RNA sequencing library, step 30 to 33. 51.Keep the plate on the magnetic stand. Let the plate rest open at room temperature (18–22°C) for 1–2 min until the pellet appears dry. Check the pellet frequently and proceed to the next step once the beads are dry. Keep the plate on the magnetic stand. Let the plate rest open at room temperature (18–22°C) for 1–2 min until the pellet appears dry. Check the pellet frequently and proceed to the next step once the beads are dry. Note: The beads will dry more quickly than in Section purification of the RNA sequencing library, step 34. 52.Keep the plate on the magnetic stand. Pipette 22 μL of the ZMM onto the beads (new sample volume: 22 μL).a.Multichannel pipetting option: Use the strip prepared in step 48 to add ZMM to the library preparation plate. Keep the plate on the magnetic stand. Pipette 22 μL of the ZMM onto the beads (new sample volume: 22 μL).a.Multichannel pipetting option: Use the strip prepared in step 48 to add ZMM to the library preparation plate. a.Multichannel pipetting option: Use the strip prepared in step 48 to add ZMM to the library preparation plate. Multichannel pipetting option: Use the strip prepared in step 48 to add ZMM to the library preparation plate. 53.Seal the plate, remove it from the magnetic stand, and flick the wells until the beads are resuspended. Seal the plate, remove it from the magnetic stand, and flick the wells until the beads are resuspended. 54.Incubate the plate at room temperature (18–22°C) for 5 min to rehydrate. Incubate the plate at room temperature (18–22°C) for 5 min to rehydrate. 55.Pre-heat a thermal cycler according to the program indicated in Table 8. Pre-heat a thermal cycler according to the program indicated in Table 8. 56.Spin down the plate, remove the seal, and place it on the magnetic stand for 2 min or longer, until the solution is completely clear. Spin down the plate, remove the seal, and place it on the magnetic stand for 2 min or longer, until the solution is completely clear. 57.Keep the plate on the magnetic stand. Transfer 20 μL of clear supernatant to a fresh 96-well PCR plate without disturbing the beads (new sample volume: 20 μL). Keep the plate on the magnetic stand. Transfer 20 μL of clear supernatant to a fresh 96-well PCR plate without disturbing the beads (new sample volume: 20 μL). Note: This step can also be performed using multichannel pipetting. Make sure that no beads are pipetted out (see Section problem 1 and potential solution in troubleshooting). 58.Seal the fresh 96-well PCR plate and spin down at 280 g for 1 min. Seal the fresh 96-well PCR plate and spin down at 280 g for 1 min. 59.Place the 96-well PCR plate on the pre-programmed thermal cycler and incubate according to the program described in Table 8. Place the 96-well PCR plate on the pre-programmed thermal cycler and incubate according to the program described in Table 8. Second PCR amplification Timing: Day 2 Library fragments not cleaved during the ZapR reaction are enriched in a second round of PCR. Since barcodes have already been added to the libraries, a single pair of primers can be used (Figure 1D). Note: Steps 60 and 62 should be performed in a separate, pre-PCR-amplification room to avoid contamination with PCR products. All other steps should be performed in a post-PCR room. 60.Bring the PCR2 Primers v3, PCR-grade water, and SeqAmp CB PCR Buffer (2×) to room temperature (18–22°C). Place the SeqAmp DNA Polymerase on a cooling unit. Bring the PCR2 Primers v3, PCR-grade water, and SeqAmp CB PCR Buffer (2×) to room temperature (18–22°C). Place the SeqAmp DNA Polymerase on a cooling unit. 61.Pre-heat a thermal cycler according to the program indicated in Table 9. Pre-heat a thermal cycler according to the program indicated in Table 9. 62.Prepare the PCR2 Master Mix (P2MM; File S1).a.Pipette 26 μL of PCR-grade water, 50 μL of SeqAmp CB PCR Buffer, 2 μL of PCR2 Primers v3, and 2 μL of SeqAmp DNA Polymerase in a tube on a cooling unit (total volume: 80 μL).b.Pipette up and down to homogenize the P2MM and spin down. Prepare the PCR2 Master Mix (P2MM; File S1).a.Pipette 26 μL of PCR-grade water, 50 μL of SeqAmp CB PCR Buffer, 2 μL of PCR2 Primers v3, and 2 μL of SeqAmp DNA Polymerase in a tube on a cooling unit (total volume: 80 μL).b.Pipette up and down to homogenize the P2MM and spin down. a.Pipette 26 μL of PCR-grade water, 50 μL of SeqAmp CB PCR Buffer, 2 μL of PCR2 Primers v3, and 2 μL of SeqAmp DNA Polymerase in a tube on a cooling unit (total volume: 80 μL). Pipette 26 μL of PCR-grade water, 50 μL of SeqAmp CB PCR Buffer, 2 μL of PCR2 Primers v3, and 2 μL of SeqAmp DNA Polymerase in a tube on a cooling unit (total volume: 80 μL). b.Pipette up and down to homogenize the P2MM and spin down. Pipette up and down to homogenize the P2MM and spin down. Note: For P2MM volumes exceeding 2000 μL (i.e., more than 25 samples), vortex it rather than pipetting up and down to ensure homogenization. Note: When using the multichannel option to add the P2MM to the library preparation plate in step 64, aliquot the P2MM into strip(s). 63.Remove the 96-well PCR plate from the thermal cycler, spin down, and keep the plate on a cooling unit. Remove the 96-well PCR plate from the thermal cycler, spin down, and keep the plate on a cooling unit. 64.Add 80 μL of P2MM to each sample well on a cooling unit (new sample volume: 100 μL). Pipette up and down to homogenize.a.Multichannel pipetting option: Use the strip(s) prepared in step 62 to add P2MM to the library preparation plate.b.Mantis option: Evaluate the time needed to add the P2MM based on Table 2. Add 80 μL of P2MM to each sample well on a cooling unit (new sample volume: 100 μL). Pipette up and down to homogenize.a.Multichannel pipetting option: Use the strip(s) prepared in step 62 to add P2MM to the library preparation plate.b.Mantis option: Evaluate the time needed to add the P2MM based on Table 2. a.Multichannel pipetting option: Use the strip(s) prepared in step 62 to add P2MM to the library preparation plate. Multichannel pipetting option: Use the strip(s) prepared in step 62 to add P2MM to the library preparation plate. b.Mantis option: Evaluate the time needed to add the P2MM based on Table 2. Mantis option: Evaluate the time needed to add the P2MM based on Table 2. 65.Seal the plate and spin down. Seal the plate and spin down. 66.Place the 96-well PCR plate on the pre-programmed thermal cycler and incubate according to the program described in Table 9. Place the 96-well PCR plate on the pre-programmed thermal cycler and incubate according to the program described in Table 9. Note: Upon starting the incubation on the thermal cycler, evaluate whether the next step (i.e., Purification of the final RNA sequencing library) can be completed on the same day (depending on the pipetting method that is chosen). When the protocol is continued on the same day, allow the AMPure XP beads to reach room temperature (18–22°C) before use in the purification of the final RNA sequencing library. Pause point: The library preparation protocol can be safely paused here. Seal the plate and store at −20°C for up to 2 weeks. Purification of the final RNA sequencing library Timing: When semi-automated pipetting is used, this step can be performed on day 2. When no semi-automated pipetting is used, this step should be initiated at day 3. In that case, bring the AMPure XP beads to room temperature (18°C–22°C) before use. The amplified RNA sequencing library is purified by immobilizing it onto AMPure XP beads. The beads are then washed and the cDNA is eluted before library validation (Figure 1D). 67.Spin down the 96-well PCR plate at 280 g for 1 min. Spin down the 96-well PCR plate at 280 g for 1 min. 68.Vortex the AMPure XP beads until they are well dispersed. Vortex the AMPure XP beads until they are well dispersed. 69.Add 100 μL of well-dispersed AMPure XP beads to the sample well (new sample volume: 200 μL).a.Multichannel pipetting option:i.Pour the beads into a disposable reagent reservoir.ii.Add 100 μL of beads to the library preparation plate.b.VIAFLO 96 option:i.Pour the beads into a VIAFLO 96-compatible reagent reservoir.ii.Add 100 μL of beads to the library preparation plate using the VIAFLO 96, with aspiration and dispense speeds set to 1. Add 100 μL of well-dispersed AMPure XP beads to the sample well (new sample volume: 200 μL).a.Multichannel pipetting option:i.Pour the beads into a disposable reagent reservoir.ii.Add 100 μL of beads to the library preparation plate.b.VIAFLO 96 option:i.Pour the beads into a VIAFLO 96-compatible reagent reservoir.ii.Add 100 μL of beads to the library preparation plate using the VIAFLO 96, with aspiration and dispense speeds set to 1. a.Multichannel pipetting option:i.Pour the beads into a disposable reagent reservoir.ii.Add 100 μL of beads to the library preparation plate. Multichannel pipetting option:i.Pour the beads into a disposable reagent reservoir.ii.Add 100 μL of beads to the library preparation plate. i.Pour the beads into a disposable reagent reservoir. Pour the beads into a disposable reagent reservoir. ii.Add 100 μL of beads to the library preparation plate. Add 100 μL of beads to the library preparation plate. b.VIAFLO 96 option:i.Pour the beads into a VIAFLO 96-compatible reagent reservoir.ii.Add 100 μL of beads to the library preparation plate using the VIAFLO 96, with aspiration and dispense speeds set to 1. VIAFLO 96 option:i.Pour the beads into a VIAFLO 96-compatible reagent reservoir.ii.Add 100 μL of beads to the library preparation plate using the VIAFLO 96, with aspiration and dispense speeds set to 1. i.Pour the beads into a VIAFLO 96-compatible reagent reservoir. Pour the beads into a VIAFLO 96-compatible reagent reservoir. ii.Add 100 μL of beads to the library preparation plate using the VIAFLO 96, with aspiration and dispense speeds set to 1. Add 100 μL of beads to the library preparation plate using the VIAFLO 96, with aspiration and dispense speeds set to 1. 70.Seal the plate and pulse vortex for 5 s. Seal the plate and pulse vortex for 5 s. 71.Incubate the plate at room temperature (18–22 °C) for 8 min to let the DNA bind to the beads. Incubate the plate at room temperature (18–22 °C) for 8 min to let the DNA bind to the beads. 72.Spin down the plate for 1 min at 280 g. Spin down the plate for 1 min at 280 g. 73.Place the plate on a magnetic stand at room temperature (18–22 °C) for 5–10 min or longer, until the solution is completely clear. Place the plate on a magnetic stand at room temperature (18–22 °C) for 5–10 min or longer, until the solution is completely clear. 74.While the plate is on the magnetic stand, remove 190 μL of supernatant without disturbing the beads. While the plate is on the magnetic stand, remove 190 μL of supernatant without disturbing the beads. Note: This step can also be performed using multichannel pipetting. Make sure that no beads are pipetted out (see Section problem 1 and potential solution in troubleshooting). 75.Repeat Section purification of the RNA sequencing library, step 30 to 33. Repeat Section purification of the RNA sequencing library, step 30 to 33. 76.Keep the plate on the magnetic stand. Let the plate rest open at room temperature (18–22 °C) for 3–7 min until the pellet appears dry. Check the pellet frequently and continue to the following step when the beads are dry. Keep the plate on the magnetic stand. Let the plate rest open at room temperature (18–22 °C) for 3–7 min until the pellet appears dry. Check the pellet frequently and continue to the following step when the beads are dry. Note: If the pellet is overdried, there will be cracks in the pellet. If this occurs, the DNA may not elute well from the beads, resulting in reduced recovery. 77.Keep the plate on the magnetic stand. Add 22 μL of PCR-grade water to cover the beads (new sample volume: 22 μL).a.Multichannel pipetting option:i.Pour PCR-grade water into a disposable reagent reservoir.ii.Add 22 μL of water to the library preparation plate.b.VIAFLO 96 option:i.Pour PCR-grade water into a VIAFLO 96-compatible reagent reservoir.ii.Add 22 of μL water to the library preparation plate using the VIAFLO 96, with aspiration speed 3 and dispense speed 7. Keep the plate on the magnetic stand. Add 22 μL of PCR-grade water to cover the beads (new sample volume: 22 μL).a.Multichannel pipetting option:i.Pour PCR-grade water into a disposable reagent reservoir.ii.Add 22 μL of water to the library preparation plate.b.VIAFLO 96 option:i.Pour PCR-grade water into a VIAFLO 96-compatible reagent reservoir.ii.Add 22 of μL water to the library preparation plate using the VIAFLO 96, with aspiration speed 3 and dispense speed 7. a.Multichannel pipetting option:i.Pour PCR-grade water into a disposable reagent reservoir.ii.Add 22 μL of water to the library preparation plate. Multichannel pipetting option:i.Pour PCR-grade water into a disposable reagent reservoir.ii.Add 22 μL of water to the library preparation plate. i.Pour PCR-grade water into a disposable reagent reservoir. Pour PCR-grade water into a disposable reagent reservoir. ii.Add 22 μL of water to the library preparation plate. Add 22 μL of water to the library preparation plate. b.VIAFLO 96 option:i.Pour PCR-grade water into a VIAFLO 96-compatible reagent reservoir.ii.Add 22 of μL water to the library preparation plate using the VIAFLO 96, with aspiration speed 3 and dispense speed 7. VIAFLO 96 option:i.Pour PCR-grade water into a VIAFLO 96-compatible reagent reservoir.ii.Add 22 of μL water to the library preparation plate using the VIAFLO 96, with aspiration speed 3 and dispense speed 7. i.Pour PCR-grade water into a VIAFLO 96-compatible reagent reservoir. Pour PCR-grade water into a VIAFLO 96-compatible reagent reservoir. ii.Add 22 of μL water to the library preparation plate using the VIAFLO 96, with aspiration speed 3 and dispense speed 7. Add 22 of μL water to the library preparation plate using the VIAFLO 96, with aspiration speed 3 and dispense speed 7. 78.Seal the plate, remove it from the magnetic stand, and flick the wells until the beads are resuspended. Seal the plate, remove it from the magnetic stand, and flick the wells until the beads are resuspended. 79.Incubate the plate at room temperature (18–22 °C) for 5 min to rehydrate. Incubate the plate at room temperature (18–22 °C) for 5 min to rehydrate. 80.Meanwhile, equilibrate the Tris Buffer of the library preparation kit at room temperature (18–22 °C; for use in step 86). Meanwhile, equilibrate the Tris Buffer of the library preparation kit at room temperature (18–22 °C; for use in step 86). 81.Spin down the plate, remove the seal, and place it on the magnetic stand for 2 min or longer, until the solution is completely clear. Spin down the plate, remove the seal, and place it on the magnetic stand for 2 min or longer, until the solution is completely clear. 82.Keep the plate on the magnetic stand. Transfer 20 μL of clear supernatant containing the purified RNA sequencing library to a fresh 96-well PCR plate (new sample volume: 20 μL). Keep the plate on the magnetic stand. Transfer 20 μL of clear supernatant containing the purified RNA sequencing library to a fresh 96-well PCR plate (new sample volume: 20 μL). Note: This step can also be performed using multichannel pipetting. Make sure that no beads are pipetted out (see Section problem 1 and potential solution in troubleshooting). Note: When a fresh 96-well PCR plate with beads was prepared in Section purification of the RNA sequencing library, step 24, transfer the clear supernatant directly to this plate, and skip step 83. 83.Add 20 μL well-dispersed AMPure XP beads to the sample well (new sample volume: 40 μL).a.Multichannel pipetting option:i.Pour the beads into a disposable reagent reservoir.ii.Add them to the library preparation plate.b.VIAFLO 96 option:i.Pour the beads into a VIAFLO 96-compatible reagent reservoir. Add them to the library preparation plate using the VIAFLO 96, with aspiration and dispense speeds set to 1. Add 20 μL well-dispersed AMPure XP beads to the sample well (new sample volume: 40 μL).a.Multichannel pipetting option:i.Pour the beads into a disposable reagent reservoir.ii.Add them to the library preparation plate.b.VIAFLO 96 option:i.Pour the beads into a VIAFLO 96-compatible reagent reservoir. Add them to the library preparation plate using the VIAFLO 96, with aspiration and dispense speeds set to 1. a.Multichannel pipetting option:i.Pour the beads into a disposable reagent reservoir.ii.Add them to the library preparation plate. Multichannel pipetting option:i.Pour the beads into a disposable reagent reservoir.ii.Add them to the library preparation plate. i.Pour the beads into a disposable reagent reservoir. Pour the beads into a disposable reagent reservoir. ii.Add them to the library preparation plate. Add them to the library preparation plate. b.VIAFLO 96 option:i.Pour the beads into a VIAFLO 96-compatible reagent reservoir. Add them to the library preparation plate using the VIAFLO 96, with aspiration and dispense speeds set to 1. VIAFLO 96 option:i.Pour the beads into a VIAFLO 96-compatible reagent reservoir. Add them to the library preparation plate using the VIAFLO 96, with aspiration and dispense speeds set to 1. i.Pour the beads into a VIAFLO 96-compatible reagent reservoir. Add them to the library preparation plate using the VIAFLO 96, with aspiration and dispense speeds set to 1. Pour the beads into a VIAFLO 96-compatible reagent reservoir. Add them to the library preparation plate using the VIAFLO 96, with aspiration and dispense speeds set to 1. 84.Seal the plate and pulse vortex for 5 s. Seal the plate and pulse vortex for 5 s. 85.Repeat steps 71–76 to perform a second round of bead clean-up. Repeat steps 71–76 to perform a second round of bead clean-up. Note: The beads will dry more quickly than in step 76. 86.Once the beads are dry, pipette 12 μL of Tris Buffer from the library preparation kit onto the beads (new sample volume: 12 μL).a.Multichannel pipetting option: Use Tris Buffer aliquoted into strips (see Section Tris Buffer in before you begin). Once the beads are dry, pipette 12 μL of Tris Buffer from the library preparation kit onto the beads (new sample volume: 12 μL).a.Multichannel pipetting option: Use Tris Buffer aliquoted into strips (see Section Tris Buffer in before you begin). a.Multichannel pipetting option: Use Tris Buffer aliquoted into strips (see Section Tris Buffer in before you begin). Multichannel pipetting option: Use Tris Buffer aliquoted into strips (see Section Tris Buffer in before you begin). Note: Depending on the number of quality checks and the sequencing volume required, consider using 20 μL instead of 12 μL. In that case, transfer 18 μL in step 90. 87.Seal the plate, remove it from the magnetic stand, and flick the wells until the beads are resuspended. Seal the plate, remove it from the magnetic stand, and flick the wells until the beads are resuspended. 88.Incubate the plate at room temperature (18–22 °C) for 5 min to rehydrate. Incubate the plate at room temperature (18–22 °C) for 5 min to rehydrate. 89.Spin down the plate, remove the seal, and place it on the magnetic stand for 2 min or longer, until the solution is completely clear. Spin down the plate, remove the seal, and place it on the magnetic stand for 2 min or longer, until the solution is completely clear. 90.Keep the plate on the magnetic stand. Transfer 10 μL of clear supernatant to a fresh 96-well PCR plate without disturbing the beads (new sample volume: 10 μL). Keep the plate on the magnetic stand. Transfer 10 μL of clear supernatant to a fresh 96-well PCR plate without disturbing the beads (new sample volume: 10 μL). Note: This step can also be performed using multichannel pipetting. Make sure that no beads are pipetted out (see Section problem 1 and potential solution in troubleshooting). Pause point: The library preparation protocol can be paused here safely. Seal the plate and store at −20 °C. Library validation Timing: Day after purification of the final RNA sequencing library (i.e., day 3 or day 4) Libraries are validated using the Fragment Analyzer System, FA 12-Capillary Array Short, and HS Small Fragment Kit. Library size distribution and average size are determined using the ProSize Fragment Analyzer data analysis software. 91.Use 1 μL of the library obtained in Section purification of the final RNA sequencing library, step 90 and add 1 μL of PCR-grade water. Use 1 μL of the library obtained in Section purification of the final RNA sequencing library, step 90 and add 1 μL of PCR-grade water. 92.Load 2 μL of diluted library onto the Fragment Analyzer and run the samples according to the manufacturer’s instructions. Load 2 μL of diluted library onto the Fragment Analyzer and run the samples according to the manufacturer’s instructions. 93.Check the size and purity of the sample. Check the size and purity of the sample. Note: The final product should be a smear from 200 bp to 1000 bp with a peak at approximately 300 bp (see Figure 2 in Section expected outcomes, and problem 2 and potential solution in troubleshooting). 94.Determine the percentage of total fragments in the 200-1000 bp range and the average fragment size, using a smear analysis in the 200–1000 bp range.a.Select one of the samples of interest and click on the tools icon in the top right corner of the Peak Table window.b.Click on the tab Smear Analysis and select fragments between 200 bp and 1000 bp.c.Apply the analysis settings to all samples of interest by selecting the appropriate option (i.e., apply to all or apply to selected) below the table. Determine the percentage of total fragments in the 200-1000 bp range and the average fragment size, using a smear analysis in the 200–1000 bp range.a.Select one of the samples of interest and click on the tools icon in the top right corner of the Peak Table window.b.Click on the tab Smear Analysis and select fragments between 200 bp and 1000 bp.c.Apply the analysis settings to all samples of interest by selecting the appropriate option (i.e., apply to all or apply to selected) below the table. a.Select one of the samples of interest and click on the tools icon in the top right corner of the Peak Table window. Select one of the samples of interest and click on the tools icon in the top right corner of the Peak Table window. b.Click on the tab Smear Analysis and select fragments between 200 bp and 1000 bp. Click on the tab Smear Analysis and select fragments between 200 bp and 1000 bp. c.Apply the analysis settings to all samples of interest by selecting the appropriate option (i.e., apply to all or apply to selected) below the table. Apply the analysis settings to all samples of interest by selecting the appropriate option (i.e., apply to all or apply to selected) below the table. Note: After applying the settings, results can be obtained by clicking the table icon in the top-right corner of the corresponding window. A new tab will appear with the Smear Analysis results. The average fragment size of the library is needed for quantification in step 105. Expected Fragment Analyzer profile of a library prepared using the SMARTer Stranded Total RNA-Seq Kit v3 – Pico Input Mammalian Fragment Analyzer profile of a good-quality library obtained from single-spun plasma from a patient diagnosed with diffuse large B-cell lymphoma (DLBCL).1 A smear from 200 bp to 1000 bp with a peak around 300 bp is expected. Library quantification and pooling Timing: Day after purification of the final RNA sequencing library (i.e., day 3 or day 4). Note that this step can already be initiated while the individual sample libraries are being validated using the Fragment Analyzer system. Individual libraries are quantified using the KAPA Library Quantification Kit and the LightCycler 480. Libraries are equimolarly pooled for sequencing. The experimental template in File S2 can be used to set up the 384-well PCR plate layout for library quantification, to analyze these data and determine the individual library concentrations, to pool the individual libraries and quantify the library pool concentration, and to analyze these data and determine the individual library concentrations. 95.Thaw the master mix (as prepared in the Section KAPA Library Quantification Kit) and DNA Standards 1-6 at room temperature (18–22 °C). Thaw the master mix (as prepared in the Section KAPA Library Quantification Kit) and DNA Standards 1-6 at room temperature (18–22 °C). Note: The KAPA SYBR FAST qPCR Master Mix is light sensitive. Protect from light during all protocol steps. 96.Thaw the library preparation plate at room temperature (18–22 °C). Thaw the library preparation plate at room temperature (18–22 °C). 97.Prepare four fresh 96-well PCR plates (dilution plate 1–4). Add LQD Buffer (prepared in the Section sample dilution buffer for library quantification) to the wells that correspond to wells that contain samples in the library preparation plate.a.Dilution plate 1 (1/50 dilution): Add 98 μL of LQD Buffer.b.Dilution plate 2 (1/2000 dilution): Add 78 μL of LQD Buffer.c.Dilution plate 3 (1/80,000 dilution): Add 78 μL of LQD Buffer.d.Dilution plate 4 (1/400,000 dilution): Add 16 μL of LQD Buffer. Prepare four fresh 96-well PCR plates (dilution plate 1–4). Add LQD Buffer (prepared in the Section sample dilution buffer for library quantification) to the wells that correspond to wells that contain samples in the library preparation plate.a.Dilution plate 1 (1/50 dilution): Add 98 μL of LQD Buffer.b.Dilution plate 2 (1/2000 dilution): Add 78 μL of LQD Buffer.c.Dilution plate 3 (1/80,000 dilution): Add 78 μL of LQD Buffer.d.Dilution plate 4 (1/400,000 dilution): Add 16 μL of LQD Buffer. a.Dilution plate 1 (1/50 dilution): Add 98 μL of LQD Buffer. Dilution plate 1 (1/50 dilution): Add 98 μL of LQD Buffer. b.Dilution plate 2 (1/2000 dilution): Add 78 μL of LQD Buffer. Dilution plate 2 (1/2000 dilution): Add 78 μL of LQD Buffer. c.Dilution plate 3 (1/80,000 dilution): Add 78 μL of LQD Buffer. Dilution plate 3 (1/80,000 dilution): Add 78 μL of LQD Buffer. d.Dilution plate 4 (1/400,000 dilution): Add 16 μL of LQD Buffer. Dilution plate 4 (1/400,000 dilution): Add 16 μL of LQD Buffer. Note: When using the VIAFLO 96, pour the LQD Buffer into a VIAFLO 96-compatible reagent reservoir, and add the appropriate buffer amount to dilution plate 1–4, with aspiration and dispense speeds set to 4. This can be done in variable-dispense mode (pre- and post-dispense volumes of 15 μL) with a single set of pipetting tips. 98.Vortex and spin down the library preparation plate. Vortex and spin down the library preparation plate. 99.Add library to the dilution plates 1–4.a.Dilution plate 1 (1/50 dilution):i.Add 2 μL of the library to obtain a total volume of 100 μL.ii.Seal the plate, vortex, and spin down.b.Dilution plate 2 (1/2000 dilution):i.Add 2 μL from dilution plate 1 to obtain a total volume of 80 μL.ii.Seal the plate, vortex, and spin down.c.Dilution plate 3 (1/80,000 dilution):i.Add 2 μL from dilution plate 2 to obtain a total volume of 80 μL.ii.Seal the plate, vortex, and spin down.d.Dilution plate 4 (1/400,000 dilution):i.Add 4 μL from dilution plate 3 to obtain a total volume of 20 μL.ii.Seal the plate, vortex, and spin down. Add library to the dilution plates 1–4.a.Dilution plate 1 (1/50 dilution):i.Add 2 μL of the library to obtain a total volume of 100 μL.ii.Seal the plate, vortex, and spin down.b.Dilution plate 2 (1/2000 dilution):i.Add 2 μL from dilution plate 1 to obtain a total volume of 80 μL.ii.Seal the plate, vortex, and spin down.c.Dilution plate 3 (1/80,000 dilution):i.Add 2 μL from dilution plate 2 to obtain a total volume of 80 μL.ii.Seal the plate, vortex, and spin down.d.Dilution plate 4 (1/400,000 dilution):i.Add 4 μL from dilution plate 3 to obtain a total volume of 20 μL.ii.Seal the plate, vortex, and spin down. a.Dilution plate 1 (1/50 dilution):i.Add 2 μL of the library to obtain a total volume of 100 μL.ii.Seal the plate, vortex, and spin down. Dilution plate 1 (1/50 dilution):i.Add 2 μL of the library to obtain a total volume of 100 μL.ii.Seal the plate, vortex, and spin down. i.Add 2 μL of the library to obtain a total volume of 100 μL. Add 2 μL of the library to obtain a total volume of 100 μL. ii.Seal the plate, vortex, and spin down. Seal the plate, vortex, and spin down. b.Dilution plate 2 (1/2000 dilution):i.Add 2 μL from dilution plate 1 to obtain a total volume of 80 μL.ii.Seal the plate, vortex, and spin down. Dilution plate 2 (1/2000 dilution):i.Add 2 μL from dilution plate 1 to obtain a total volume of 80 μL.ii.Seal the plate, vortex, and spin down. i.Add 2 μL from dilution plate 1 to obtain a total volume of 80 μL. Add 2 μL from dilution plate 1 to obtain a total volume of 80 μL. ii.Seal the plate, vortex, and spin down. Seal the plate, vortex, and spin down. c.Dilution plate 3 (1/80,000 dilution):i.Add 2 μL from dilution plate 2 to obtain a total volume of 80 μL.ii.Seal the plate, vortex, and spin down. Dilution plate 3 (1/80,000 dilution):i.Add 2 μL from dilution plate 2 to obtain a total volume of 80 μL.ii.Seal the plate, vortex, and spin down. i.Add 2 μL from dilution plate 2 to obtain a total volume of 80 μL. Add 2 μL from dilution plate 2 to obtain a total volume of 80 μL. ii.Seal the plate, vortex, and spin down. Seal the plate, vortex, and spin down. d.Dilution plate 4 (1/400,000 dilution):i.Add 4 μL from dilution plate 3 to obtain a total volume of 20 μL.ii.Seal the plate, vortex, and spin down. Dilution plate 4 (1/400,000 dilution):i.Add 4 μL from dilution plate 3 to obtain a total volume of 20 μL.ii.Seal the plate, vortex, and spin down. i.Add 4 μL from dilution plate 3 to obtain a total volume of 20 μL. Add 4 μL from dilution plate 3 to obtain a total volume of 20 μL. ii.Seal the plate, vortex, and spin down. Seal the plate, vortex, and spin down. 100.Prepare two fresh 384-well PCR plates according to the sheet ‘qPCR plate layout’ in File S2 to quantify the 1/80,000 (qPCR plate 1) and 1/400,000 (qPCR plate 2) library dilutions. Prepare two fresh 384-well PCR plates according to the sheet ‘qPCR plate layout’ in File S2 to quantify the 1/80,000 (qPCR plate 1) and 1/400,000 (qPCR plate 2) library dilutions. 101.Add 3 μL of master mix (step 95) to qPCR plate 1 and 2 to wells containing sample libraries, or DNA Standards 1-6 of the KAPA Library Quantification Kit or NTC. Seal the plates and spin down.a.Multichannel pipetting option: When using an electronic multichannel pipette, use the multidispense function with an aliquot volume of 3 μL, an aliquot number of 6, and aspiration and dispense speeds of 3.b.Mantis option. Add 3 μL of master mix (step 95) to qPCR plate 1 and 2 to wells containing sample libraries, or DNA Standards 1-6 of the KAPA Library Quantification Kit or NTC. Seal the plates and spin down.a.Multichannel pipetting option: When using an electronic multichannel pipette, use the multidispense function with an aliquot volume of 3 μL, an aliquot number of 6, and aspiration and dispense speeds of 3.b.Mantis option. a.Multichannel pipetting option: When using an electronic multichannel pipette, use the multidispense function with an aliquot volume of 3 μL, an aliquot number of 6, and aspiration and dispense speeds of 3. Multichannel pipetting option: When using an electronic multichannel pipette, use the multidispense function with an aliquot volume of 3 μL, an aliquot number of 6, and aspiration and dispense speeds of 3. b.Mantis option. Mantis option. 102.Add 2 μL of library dilution plate 3 to qPCR plate 1, and 2 μL of library dilution plate 4 to qPCR plate 2, as well as 2 μL of the DNA Standards 1–6 and NTC to the corresponding wells, to obtain 5 μL qPCR reactions.a.Multichannel pipetting option: When using an electronic multichannel pipette, use the multidispense function with an aliquot volume of 2 μL, an aliquot number of 3, and aspiration and dispense speeds set to 3.b.VIAFLO 96 option: Add the libraries to the qPCR plates using the repeat dispense function, with a pre- and post-dispense volume of 2 μL and aspiration and dispense speeds set to 4. Add 2 μL of library dilution plate 3 to qPCR plate 1, and 2 μL of library dilution plate 4 to qPCR plate 2, as well as 2 μL of the DNA Standards 1–6 and NTC to the corresponding wells, to obtain 5 μL qPCR reactions.a.Multichannel pipetting option: When using an electronic multichannel pipette, use the multidispense function with an aliquot volume of 2 μL, an aliquot number of 3, and aspiration and dispense speeds set to 3.b.VIAFLO 96 option: Add the libraries to the qPCR plates using the repeat dispense function, with a pre- and post-dispense volume of 2 μL and aspiration and dispense speeds set to 4. a.Multichannel pipetting option: When using an electronic multichannel pipette, use the multidispense function with an aliquot volume of 2 μL, an aliquot number of 3, and aspiration and dispense speeds set to 3. Multichannel pipetting option: When using an electronic multichannel pipette, use the multidispense function with an aliquot volume of 2 μL, an aliquot number of 3, and aspiration and dispense speeds set to 3. b.VIAFLO 96 option: Add the libraries to the qPCR plates using the repeat dispense function, with a pre- and post-dispense volume of 2 μL and aspiration and dispense speeds set to 4. VIAFLO 96 option: Add the libraries to the qPCR plates using the repeat dispense function, with a pre- and post-dispense volume of 2 μL and aspiration and dispense speeds set to 4. 103.Seal the plates, vortex, and spin down. Seal the plates, vortex, and spin down. Note: Store the qPCR plates at −20°C if it is not possible to immediately proceed to step 104. 104.Run the qPCR plates on a LightCycler480 platform according to the program in Table 10 and detection format SYBR Green I/HRM Dye. Run the qPCR plates on a LightCycler480 platform according to the program in Table 10 and detection format SYBR Green I/HRM Dye. 105.Use the Cq values and average fragment sizes of the libraries (determined using the Fragment Analyzer software in Section library validation, step 94) to calculate the average individual library concentrations using File S2. Use the Cq values and average fragment sizes of the libraries (determined using the Fragment Analyzer software in Section library validation, step 94) to calculate the average individual library concentrations using File S2. 106.To equimolarly pool the individual libraries, dilute the libraries to the lowest concentrated individual library.Note: Be sure not to dilute the libraries below the minimum concentration and volume needed for loading into the Illumina sequencing run (Table 11). Samples with library concentrations below this minimum loading concentration and volume need to be either excluded from pooling or added to the maximum volume. Note that the latter will likely yield fewer sequencing reads for these samples.a.Fill in the library volume to be used for the dilution (usually 2 μL is sufficient) and evaluate the required Pooling Buffer volume for each sample (in the sheet ‘Pooling’ in File S2).Note: Make sure that the total volume of the individual diluted libraries does not exceed 200 μL (see Section problem 3 and potential solution in troubleshooting).b.Add the appropriate volumes of Pooling Buffer to a fresh 96-well PCR plate.Note: The Mantis Liquid Dispenser can be used for this step. Do not mix up the LQD Buffer (used in step 97) and the Pooling Buffer (used in step 106). The Pooling Buffer does not contain Tween20. To equimolarly pool the individual libraries, dilute the libraries to the lowest concentrated individual library.Note: Be sure not to dilute the libraries below the minimum concentration and volume needed for loading into the Illumina sequencing run (Table 11). Samples with library concentrations below this minimum loading concentration and volume need to be either excluded from pooling or added to the maximum volume. Note that the latter will likely yield fewer sequencing reads for these samples.a.Fill in the library volume to be used for the dilution (usually 2 μL is sufficient) and evaluate the required Pooling Buffer volume for each sample (in the sheet ‘Pooling’ in File S2).Note: Make sure that the total volume of the individual diluted libraries does not exceed 200 μL (see Section problem 3 and potential solution in troubleshooting).b.Add the appropriate volumes of Pooling Buffer to a fresh 96-well PCR plate.Note: The Mantis Liquid Dispenser can be used for this step. Do not mix up the LQD Buffer (used in step 97) and the Pooling Buffer (used in step 106). The Pooling Buffer does not contain Tween20. Note: Be sure not to dilute the libraries below the minimum concentration and volume needed for loading into the Illumina sequencing run (Table 11). Samples with library concentrations below this minimum loading concentration and volume need to be either excluded from pooling or added to the maximum volume. Note that the latter will likely yield fewer sequencing reads for these samples. a.Fill in the library volume to be used for the dilution (usually 2 μL is sufficient) and evaluate the required Pooling Buffer volume for each sample (in the sheet ‘Pooling’ in File S2).Note: Make sure that the total volume of the individual diluted libraries does not exceed 200 μL (see Section problem 3 and potential solution in troubleshooting). Fill in the library volume to be used for the dilution (usually 2 μL is sufficient) and evaluate the required Pooling Buffer volume for each sample (in the sheet ‘Pooling’ in File S2).Note: Make sure that the total volume of the individual diluted libraries does not exceed 200 μL (see Section problem 3 and potential solution in troubleshooting). Note: Make sure that the total volume of the individual diluted libraries does not exceed 200 μL (see Section problem 3 and potential solution in troubleshooting). b.Add the appropriate volumes of Pooling Buffer to a fresh 96-well PCR plate.Note: The Mantis Liquid Dispenser can be used for this step. Do not mix up the LQD Buffer (used in step 97) and the Pooling Buffer (used in step 106). The Pooling Buffer does not contain Tween20. Add the appropriate volumes of Pooling Buffer to a fresh 96-well PCR plate.Note: The Mantis Liquid Dispenser can be used for this step. Do not mix up the LQD Buffer (used in step 97) and the Pooling Buffer (used in step 106). The Pooling Buffer does not contain Tween20. Note: The Mantis Liquid Dispenser can be used for this step. Do not mix up the LQD Buffer (used in step 97) and the Pooling Buffer (used in step 106). The Pooling Buffer does not contain Tween20. 107.Add the appropriate volume of sample libraries to the 96-well PCR plate.a.Multichannel pipetting option.b.VIAFLO 96 option: Add the libraries to the qPCR plates using a pre- and post-dispense volume of 2 μL. Add the appropriate volume of sample libraries to the 96-well PCR plate.a.Multichannel pipetting option.b.VIAFLO 96 option: Add the libraries to the qPCR plates using a pre- and post-dispense volume of 2 μL. a.Multichannel pipetting option. Multichannel pipetting option. b.VIAFLO 96 option: Add the libraries to the qPCR plates using a pre- and post-dispense volume of 2 μL. VIAFLO 96 option: Add the libraries to the qPCR plates using a pre- and post-dispense volume of 2 μL. 108.Seal the plate, vortex, and spin down. Seal the plate, vortex, and spin down. 109.Pipette an identical volume from each library into a 1.5 mL LoBind tube.Note: This volume depends on the concentration of the pool, the number of individual libraries, and the Illumina equipment selected for sequencing. Usually, it ranges between 3 and 5 μL (in the sheet ‘Pooling’ in File S2). Ensure the final pool volume is sufficient to load onto the Illumina equipment selected for sequencing (Table 11).a.Multichannel pipetting option:i.Transfer an identical volume from every row of the 96-well PCR plate into a well strip.ii.Pool the wells from the strip into a 1.5 mL LoBind tube.Note: Make sure to transfer all the content from the wells. Pipette an identical volume from each library into a 1.5 mL LoBind tube.Note: This volume depends on the concentration of the pool, the number of individual libraries, and the Illumina equipment selected for sequencing. Usually, it ranges between 3 and 5 μL (in the sheet ‘Pooling’ in File S2). Ensure the final pool volume is sufficient to load onto the Illumina equipment selected for sequencing (Table 11).a.Multichannel pipetting option:i.Transfer an identical volume from every row of the 96-well PCR plate into a well strip.ii.Pool the wells from the strip into a 1.5 mL LoBind tube.Note: Make sure to transfer all the content from the wells. Note: This volume depends on the concentration of the pool, the number of individual libraries, and the Illumina equipment selected for sequencing. Usually, it ranges between 3 and 5 μL (in the sheet ‘Pooling’ in File S2). Ensure the final pool volume is sufficient to load onto the Illumina equipment selected for sequencing (Table 11). a.Multichannel pipetting option:i.Transfer an identical volume from every row of the 96-well PCR plate into a well strip.ii.Pool the wells from the strip into a 1.5 mL LoBind tube.Note: Make sure to transfer all the content from the wells. Multichannel pipetting option:i.Transfer an identical volume from every row of the 96-well PCR plate into a well strip.ii.Pool the wells from the strip into a 1.5 mL LoBind tube.Note: Make sure to transfer all the content from the wells. i.Transfer an identical volume from every row of the 96-well PCR plate into a well strip. Transfer an identical volume from every row of the 96-well PCR plate into a well strip. ii.Pool the wells from the strip into a 1.5 mL LoBind tube.Note: Make sure to transfer all the content from the wells. Pool the wells from the strip into a 1.5 mL LoBind tube.Note: Make sure to transfer all the content from the wells. Note: Make sure to transfer all the content from the wells. 110.Validate the library pool using the Fragment Analyzer System, as described in the Section library validation. Validate the library pool using the Fragment Analyzer System, as described in the Section library validation. Note: The average fragment size of the library pool is needed for quantification in step 111 (see Section problem 2 and potential solution in troubleshooting). 111.Perform three concentration measurements of the final library pool using a Qubit 4 Fluorometer and 1X dsDNA HS Assay Kit to calculate the mean library pool concentration (in the sheet ‘Final Pool’ in File S2). Perform three concentration measurements of the final library pool using a Qubit 4 Fluorometer and 1X dsDNA HS Assay Kit to calculate the mean library pool concentration (in the sheet ‘Final Pool’ in File S2). Table 10Protocol step 104: LightCycler 480 program for library quantificationStepsAnalysis modeCyclesTemperatureAcquisition modeTimeRamp rate (°C/s)Acquisitions (per °C)Enzyme ActivationNone195°CNone5 min4.8NoneAmplification–Quantification–35–95°CNone30 s4.8None60°CSingle45 s2.5NoneMelt curve––Melting curves––1––95°CNone5 s4.8None60°CNone1 min2.5None95°CContinuousNone0.115CoolingNone140°CNone3 min2.5NoneEstimated time: ± 75 min. Protocol step 104: LightCycler 480 program for library quantification Estimated time: ± 75 min. Table 11Illumina sequencers and flow cells, and corresponding loading concentrations, volumes, and %PhiXSequencer - flow cellaRead lengthsMinimum concentration (pM)Minimum volume (μL)%PhiXNextSeq 2000 - P22 × 50 bp, 2 × 100 bp650202NovaSeq 6000 - SP2 × 50 bp, 2 × 100 bp5801002NovaSeq 6000 - S12 × 100 bp5801002NovaSeq 6000 - S22 × 100 bp5801502aThis overview is limited to sequencers, flow cells, and read lengths used so far by the OncoRNALab to perform total RNA sequencing on liquid biopsies, using the SMARTer Stranded Total RNA-Seq Kit v3 – Pico Input Mammalian or the SMART-Seq Total RNA Pico Input with UMIs (ZapR Mammalian) kit for library preparation. Illumina sequencers and flow cells, and corresponding loading concentrations, volumes, and %PhiX This overview is limited to sequencers, flow cells, and read lengths used so far by the OncoRNALab to perform total RNA sequencing on liquid biopsies, using the SMARTer Stranded Total RNA-Seq Kit v3 – Pico Input Mammalian or the SMART-Seq Total RNA Pico Input with UMIs (ZapR Mammalian) kit for library preparation. Library size selection (optional) Timing: Day after library quantification and pooling (i.e., day 4 or day 5) Library size selection using the Pippin Prep System and Pippin Gel Cassette should only be performed in the presence of adapter dimers (see Section problem 2 and potential solution in troubleshooting) to increase the purity of the final library. This size selection step is performed according to the manufacturer’s operations manual and is followed by an ethanol purification step. 112.Equilibrate the marker/loading solution mix and electrophoresis buffer at room temperature (18–22 °C). Equilibrate the marker/loading solution mix and electrophoresis buffer at room temperature (18–22 °C). 113.Rinse the electrode array by filling the rinse cassette with deionized water, loading it onto the sample tray, closing the Pippin Prep lid, and incubating for 20 s. Rinse the electrode array by filling the rinse cassette with deionized water, loading it onto the sample tray, closing the Pippin Prep lid, and incubating for 20 s. 114.Go to the editor tab of the Pippin Prep software to write a new protocol.a.Select the correct cassette type and programming mode range with size ranging from 200 to 600 bp.b.Use the setting ‘off’ in the reference lane indicator field.c.Indicate the use of internal standards and save the protocol. Go to the editor tab of the Pippin Prep software to write a new protocol.a.Select the correct cassette type and programming mode range with size ranging from 200 to 600 bp.b.Use the setting ‘off’ in the reference lane indicator field.c.Indicate the use of internal standards and save the protocol. a.Select the correct cassette type and programming mode range with size ranging from 200 to 600 bp. Select the correct cassette type and programming mode range with size ranging from 200 to 600 bp. b.Use the setting ‘off’ in the reference lane indicator field. Use the setting ‘off’ in the reference lane indicator field. c.Indicate the use of internal standards and save the protocol. Indicate the use of internal standards and save the protocol. 115.Calibrate the Pippin Prep optical system.a.Place the calibration fixture into the optical nest and follow the instructions in the manufacturer’s operations manual.b.Remove the calibration fixture when the procedure is completed. Calibrate the Pippin Prep optical system.a.Place the calibration fixture into the optical nest and follow the instructions in the manufacturer’s operations manual.b.Remove the calibration fixture when the procedure is completed. a.Place the calibration fixture into the optical nest and follow the instructions in the manufacturer’s operations manual. Place the calibration fixture into the optical nest and follow the instructions in the manufacturer’s operations manual. b.Remove the calibration fixture when the procedure is completed. Remove the calibration fixture when the procedure is completed. 116.Prepare the cassette and perform a continuity test as described in the manufacturer’s operation manual. Prepare the cassette and perform a continuity test as described in the manufacturer’s operation manual. Note: The marker/loading solution mix is light sensitive. Protect from light. 117.Prepare a library pool aliquot of 150 μL from the library pool obtained in Section library quantification and pooling, step 109. Prepare a library pool aliquot of 150 μL from the library pool obtained in Section library quantification and pooling, step 109. 118.Vortex and spin down the marker/loading solution mix. Vortex and spin down the marker/loading solution mix. 119.Add 50 μL of marker/loading solution mix to the library pool aliquot. Vortex thoroughly and spin down. Add 50 μL of marker/loading solution mix to the library pool aliquot. Vortex thoroughly and spin down. 120.Load the pool across the five different lanes and run the protocol as described in the manufacturer’s operations manual. Load the pool across the five different lanes and run the protocol as described in the manufacturer’s operations manual. 121.Recover 200 μL (pooled from the five different lanes) of size-selected library pool in a 1.5 mL LoBind tube as described in the manufacturer’s operations manual. Recover 200 μL (pooled from the five different lanes) of size-selected library pool in a 1.5 mL LoBind tube as described in the manufacturer’s operations manual. 122.Pre-chill a microcentrifuge at 4 °C. Pre-chill a microcentrifuge at 4 °C. 123.Pre-chill 5 mL 100% ethanol at −20 °C. Pre-chill 5 mL 100% ethanol at −20 °C. 124.Add 2 μL of glycogen, 30 μL of 3 M sodium acetate, and 977 μL of chilled ethanol to the size-selected library pool, and immediately centrifuge at 20,000 g for 20 min at 4 °C in the chilled microcentrifuge. Add 2 μL of glycogen, 30 μL of 3 M sodium acetate, and 977 μL of chilled ethanol to the size-selected library pool, and immediately centrifuge at 20,000 g for 20 min at 4 °C in the chilled microcentrifuge. 125.Pre-heat a thermomixer at 37 °C. Pre-heat a thermomixer at 37 °C. 126.Prepare 2,500 μL of 70% ethanol at room temperature (18–22 °C). Prepare 2,500 μL of 70% ethanol at room temperature (18–22 °C). 127.Remove and discard the supernatant, leaving the pellet intact. Remove and discard the supernatant, leaving the pellet intact. 128.Wash the pellet with 500 μL of 70% ethanol at room temperature (18–22 °C). Wash the pellet with 500 μL of 70% ethanol at room temperature (18–22 °C). 129.Centrifuge at 20,000 g for 2 min at room temperature (18–22 °C). Centrifuge at 20,000 g for 2 min at room temperature (18–22 °C). 130.Remove and discard the supernatant, leaving the pellet intact. Remove and discard the supernatant, leaving the pellet intact. 131.Dry the pellet by placing the tube with the lid open in the heated thermomixer for 5 to 10 min, or until dry. Dry the pellet by placing the tube with the lid open in the heated thermomixer for 5 to 10 min, or until dry. 132.Resuspend the pellet in 13 μL of Pooling Buffer, as prepared in the Section sample pooling buffer for library pooling. Resuspend the pellet in 13 μL of Pooling Buffer, as prepared in the Section sample pooling buffer for library pooling. 133.Validate the library pool on the Fragment Analyzer as described in Section library validation. Validate the library pool on the Fragment Analyzer as described in Section library validation. Note: Primer dimers should be removed, as demonstrated in Figure 3 (see section problem 2 and potential solution in troubleshooting). Fragment Analyzer profile of a library pool prepared using the SMARTer Stranded Total RNA-Seq Kit v3 – Pico Input Mammalian, demonstrating the presence of primer dimers Fragment Analyzer profile of a library pool obtained from plasma of 80 IgM gammopathy patients. The peak at 125-200 bp before Pippin Prep demonstrates the presence of primer dimers. The Fragment Analyzer profile of the same library pool after Pippin Prep size selection and ethanol purification demonstrates the absence of primer dimers. Note that the peak at 100 bp is due to Pippin Prep reagents. Sequencing Timing: Hands-on time is 0.5–1 h, depending on the selected sequencing method. 134.Sequence the library pool on an Illumina instrument (NextSeq 500, HiSeq 2/3000, or NovaSeq 6000). Sequence the library pool on an Illumina instrument (NextSeq 500, HiSeq 2/3000, or NovaSeq 6000). Note: For example, in Decruyenaere et al.,1 the library was paired-end sequenced (2×100 nucleotides) on a NovaSeq 6000 instrument, using a NovaSeq S2 kit with standard workflow loading of 0.65 nM (2% PhiX). Expected outcomes Library validation After Section purification of the final RNA sequencing library, step 90, libraries such as the one presented in Figure 2 are expected to be generated, with a smear from 200 bp to 1000 bp and a peak at approximately 300 bp. Sequencing An example of expected sequencing run output using equipment and run conditions indicated in Table 11 is shown in Table 12. Table 12Example of expected sequencing run output using equipment and run conditions indicated in Table 11Sequencer - flow cella%PF%OccupiedReads PF (million)%PhiX%≥Q30NextSeq 2000 - P277–8382–945164.6291.31NovaSeq 6000 - SP68–8296–98939–10250.57–1.0488.17–88.33NovaSeq 6000 - S174–9188–972090–22230.78–3.1988.51–92.01NovaSeq 6000 - S276–8497–9846181.1989.99aThis overview is limited to sequencers and flow cells used so far by the OncoRNALab to perform total RNA sequencing on liquid biopsies, using the SMARTer Stranded Total RNA-Seq Kit v3 – Pico Input Mammalian or the SMART-Seq Total RNA Pico Input with UMIs (ZapR Mammalian) kit for library preparation. %PF: the percentage of clusters passing the filter that are assigned to the index. %Occupied: the percentage of wells (for patterned flow cells) or nonduplicated spots (for non-patterned flow cells) on the flow cell containing clusters. Reads PF: the number of clusters (in millions) passing filtering. %PhiX: the percentage of reads aligned to the PhiX genome. %≥Q30: the percentage of bases with a quality score of 30 or higher. Example of expected sequencing run output using equipment and run conditions indicated in Table 11 This overview is limited to sequencers and flow cells used so far by the OncoRNALab to perform total RNA sequencing on liquid biopsies, using the SMARTer Stranded Total RNA-Seq Kit v3 – Pico Input Mammalian or the SMART-Seq Total RNA Pico Input with UMIs (ZapR Mammalian) kit for library preparation. %PF: the percentage of clusters passing the filter that are assigned to the index. %Occupied: the percentage of wells (for patterned flow cells) or nonduplicated spots (for non-patterned flow cells) on the flow cell containing clusters. Reads PF: the number of clusters (in millions) passing filtering. %PhiX: the percentage of reads aligned to the PhiX genome. %≥Q30: the percentage of bases with a quality score of 30 or higher. Data analysis After data analysis, it is important to assess data quality, as outlined in the Section quantification and statistical analysis below. Four parameters are essential for this sequencing data: strandedness, splicing, spike-in fraction, and duplication rates (also see problem 5 and potential solution in Section troubleshooting). To provide realistic values for these parameters, we selected the highest-quality samples from Decruyenaere et al.1 (Figure 4). First, we expect stranded sequencing data from this library preparation. More specifically, we expect the vast majority of reads to map in the ‘1+-,1-+,2++,2--’ orientation (following the RSeQC infer_experiment notation, Figure 4A). Second, although not all reads should cover splice junctions (since we are dealing with short-read sequencing), we expect about 10% of reads to map to known splice junctions (Figure 4B). Deviating values in these first two parameters might indicate DNA contamination of the RNA sample.23 Third, the fraction of spike-in RNA in the final counts should be high enough to be useful for normalization without taking up too much of the data. Therefore, we recommend that the spike-in fraction (ERCC or Sequin) not exceed 5-10% (Figure 4C). Note that altered Sequin spike-in vs. ERCC spike-in ratios during data analysis, can indicate issues during RNA purification. Lastly, duplication rates indicate the degree of PCR duplicates and increase with a lower starting amount of RNA. Since the protocol works with low amounts of RNA, specifically, we expect a large proportion of PCR duplicates. Our high-quality samples show a mode of around 37% of duplicates. Extremely high duplication rates (>90%) indicate low RNA input (Figure 4D). Incorrect plasma preparation or poor blood tube choice may lead to an increased or decreased RNA concentration or integrity. This can also result in deviations in these last two parameters: unexpected spike-in RNA ratios and high duplication rates (Figures 4C and 4D). Quality control parameters for 20 high-quality samples from Decruyenaere et al. (A) Representation of the output of infer_experiment from RSeQC.17 Each dot is a sample with outliers located outside the boxplot tails. (B) Density plot showing the percentage of reads covering the splice sites. The x-axis is limited to the minimum and maximum values obtained in these data. (C) Percentage of reads mapping to ERCC and Sequin spike-in RNA. Each dot is a sample with outliers located outside the boxplot tails. The y-axis is shown as a logarithmic scale. (D) Density plot showing the percentage of reads removed after duplication using UMI-tools.13 The x-axis is limited to the minimum and maximum values obtained in these data. Quantification and statistical analysis When reviewing sequencing results, it is essential to carefully examine the quality control (QC) metrics before proceeding with downstream analyses. Illumina’s BaseSpace platform (basespace.illumina.com) provides valuable run metrics, including the percentage of clusters passing filter that are assigned to the index (%PF), the percentage of wells (for patterned flow cells) or nonduplicated spots (for nonpatterned flow cells) on the flow cell containing clusters (%Occupied), the number of clusters (in millions) passing filtering (Reads PF), the percentage of reads aligned to the PhiX genome (%PhiX) and the percentage of bases with a quality score of 30 or higher (%≥Q30). The %PF should be ideally above 75-80% and the %Occupied above 85% (see Table 12 in Section expected outcomes; see Section problem 4 and potential solution in troubleshooting). For total RNA sequencing, we target approximately 20 million reads per sample for gene-level quantification or gene set enrichment analysis, and around 40 million reads per sample for more detailed investigations of low-abundance genes. Evaluate whether the proportion of reads aligning to the PhiX control corresponds to the concentration loaded during sequencing. Ideally, the %≥Q30 should be around 90% or higher. For a more detailed evaluation of sequencing quality, additional QC analysis should be performed using FastQC (v0.12.1). Raw sequencing data can be processed using various tools. We use a comprehensive Snakemake workflow, available at Zenodo (Zenodo: https://doi.org/10.5281/zenodo.19113165). The workflow leverages multiple bioinformatics tools, each executed within its own conda environment to ensure reproducibility and ease of dependency management. It is adaptable to both single-end (SE) and paired-end (PE) sequencing data, and it supports both versions of the total RNA library preparation protocol. The data folders and parameters can be adjusted in the configuration file (config/config.yml), where the sequencing parameter specifies the sequencing type (either ‘se’ for single-end or ‘pe’ for paired-end). Our proposed workflow for alignment-based analysis includes the following steps. 1.FASTQ files from different lanes are combined per sample and read end (R1 or R2 for paired-end sequencing data). FASTQ files from different lanes are combined per sample and read end (R1 or R2 for paired-end sequencing data). 2.For paired-end sequencing data, UMIs are extracted from Read 2 using UMI-tools13 (v1.1.6) to facilitate UMI deduplication in step 4 below. For paired-end sequencing data, UMIs are extracted from Read 2 using UMI-tools13 (v1.1.6) to facilitate UMI deduplication in step 4 below. 3.Reads are mapped to a reference genome using STAR14 (v2.7.11b), a splice-aware aligner. Resulting BAM files are indexed using SAMtools15 (v1.21). Reads are mapped to a reference genome using STAR14 (v2.7.11b), a splice-aware aligner. Resulting BAM files are indexed using SAMtools15 (v1.21). 4.Deduplication is performed according to the protocol and sequencing data type. For paired-end sequencing, deduplication is done based on UMIs with UMI-tools13 (v1.1.6). For single-end sequencing data where UMIs are not available in Read 1, Picard24 (v3.3.0) can be used for duplicate removal. Deduplication is performed according to the protocol and sequencing data type. For paired-end sequencing, deduplication is done based on UMIs with UMI-tools13 (v1.1.6). For single-end sequencing data where UMIs are not available in Read 1, Picard24 (v3.3.0) can be used for duplicate removal. 5.Gene counts are determined with HTSeq16 (v2.0.5) in strand-specific mode, considering only uniquely mapped reads. Gene counts are determined with HTSeq16 (v2.0.5) in strand-specific mode, considering only uniquely mapped reads. 6.DNA contamination is evaluated based on strandedness and splicing information obtained with RSeQC17 (v5.0.4) as described by Verwilt et al.23 An Rmarkdown (v.2.29) file is generated to provide an interactive view of these two metrics. DNA contamination is evaluated based on strandedness and splicing information obtained with RSeQC17 (v5.0.4) as described by Verwilt et al.23 An Rmarkdown (v.2.29) file is generated to provide an interactive view of these two metrics. 7.Overall quality is assessed using FastQC18 (v0.12.1), considering both raw sequencing data and aligned BAM files. Overall quality is assessed using FastQC18 (v0.12.1), considering both raw sequencing data and aligned BAM files. We recommend applying a threshold to filter out low-abundant, noisy genes. We typically set the cut-off at the count level that removes at least 95% of single-positive replicate values, following the method described by Mestdagh et al.25 To demonstrate the pipeline’s functionality and enable users to verify its compatibility with their infrastructure, test data (for both protocols and sequencing modes) is available in the ‘tests’ subfolder of the Zenodo repository. This includes (size-limited) sequencing data as well as intermediate and final output files. Limitations High-throughput sequencing platforms, including the Illumina system used here, require PCR amplification during library preparation to generate sufficient cDNA molecules for sequencing. In workflows optimized for biofluids, which are considered low-input samples, the number of PCR cycles is typically increased. This amplification step inevitably produces PCR duplicates – reads derived from the same original cDNA molecule – which can bias downstream analyses if not adequately addressed. In the SMART-Seq Total RNA Pico Input with UMIs protocol, a Unique Molecular Identifier is incorporated during reverse transcription to mitigate PCR amplification bias. This UMI is positioned at the 5′ end of Read 2, facilitating the identification of PCR duplicates in paired-end sequencing data. However, for single-end sequencing, this UMI is absent, rendering UMI-based deduplication unfeasible. Consequently, when processing single-end RNA sequencing data from biofluid samples, it is crucial to employ alternative computational tools to address PCR duplicates. Tools such as Picard (http://broadinstitute.github.io/picard/) or BBMap’s Clumpify utility (https://sourceforge.net/projects/bbmap/) can be utilized during the pre-processing stage to remove duplicates effectively. The expected percentage of duplicated reads varies depending on the tool used and the type of biofluid. While our proposed computational workflow focuses on linear RNAs, circular RNAs can also be detected using this protocol. Quantification of circular RNAs is typically based on their characteristic backsplice junctions, and several specialized bioinformatics tools are available for this purpose.26 Troubleshooting Problem 1 During the purification steps, the wells of the library preparation plate contain AMPure XP beads, and the supernatant needs to be discarded (e.g., Section purification of the RNA sequencing library, step 29) or transferred to a fresh 96-well PCR plate (e.g., Section purification of the RNA sequencing library, step 39). Aspiration of the supernatant might result in the aspiration of (a small amount of) beads. Potential solution Two potential solutions are proposed, depending on whether the supernatant is discarded or transferred. (1) If beads are observed in the pipette tips during supernatant removal, the fluid should be pipetted back into the original 96-well PCR plate. Incubate the plate for 1 or 2 more min on the magnetic stand. Lower the volume to be removed by 3–5 μL, and try again. Repeat if needed. Make sure that no beads are pipetted out. (2) If beads are observed in the pipette tips during supernatant transfer, the fluid also needs to be pipetted back into the original 96-well PCR plate. Then, add an additional volume (3–5 μL) of PCR-grade water, ZMM or Tris Buffer of the library preparation kit to the wells, depending on the solution in which the beads were rehydrated. Incubate the plate for 1 or 2 more min on the magnetic stand. Try again to transfer the indicated volume and repeat if needed. Make sure that no beads are pipetted out. As such, transfer volumes and continuation of the protocol are secured. Problem 2 During the ‘Library validation’ (Section library validation, step 93) a small peak might appear before the expected library size. These peaks in the 125–200 bp range pinpoint the presence of primer dimers. Potential solution In that case, after pooling the individual libraries (Section library quantification and pooling, step 109), the final library pool should be re-evaluated for primer dimers (example in Figure 3). To assess the amount of dimers present in the library pool, a smear analysis can be performed using the ProSize Fragment Analyzer data analysis software (Agilent) to determine the percentage of fragments in the 125–200 bp range (similarly as described in Section library validation, step 94). When this percentage exceeds 15%, it is recommended to perform library size selection using Pippin Prep (Section library quantification and pooling). Problem 3 Some individual library concentrations may be too high to be used immediately for pooling without exceeding the maximum well volume of a 96-well PCR plate (i.e., 200 μL, Section library quantification and pooling, step 106). Potential solution For these libraries, make a subdilution series from 4 to 10 nM. Then, further dilute to the selected pool concentration. Problem 4 The %Occupied and %PF metrics deviate from the ideally obtained values (Section quantification and statistical analysis). This might indicate suboptimal loading concentrations during the sequencing run. Potential solution To optimize loading concentrations on the NextSeq 2000 or NovaSeq 6000 sequencing instrument, the %Occupied and %PF metrics should be evaluated in a Sequencing Analysis View (SAV) plot to determine if a run was underloaded, optimally loaded, or overloaded. If the resulting plot indicates the run is underloaded or overloaded, increase or decrease the loading concentration, respectively, to optimally load the library pool. Problem 5 Quality control plots may deviate from the expected profiles described above (Figures 4A–4D; see Section data analysis in expected outcomes). Such deviations do not necessarily invalidate the experiment but may indicate technical issues that require careful interpretation, exclusion of specific samples, or protocol optimization before continuing with downstream analyses. Common issues observed include: •Evidence of DNA contamination: Suggested by a reduced proportion of reads mapping to the expected stranded orientation (Figure 4A) and/or a substantially lower fraction of reads mapping to known splice junctions (typically <10%) (Figure 4B). Evidence of DNA contamination: Suggested by a reduced proportion of reads mapping to the expected stranded orientation (Figure 4A) and/or a substantially lower fraction of reads mapping to known splice junctions (typically <10%) (Figure 4B). •Low spike-in fractions (Figure 4C): Spike-in RNA (ERCC or Sequin) is intended to support normalization and additional quality checks. If spike-in fractions are substantially below the recommended 5–10%, spike-ins may be insufficient for these purposes. Low spike-in fractions (Figure 4C): Spike-in RNA (ERCC or Sequin) is intended to support normalization and additional quality checks. If spike-in fractions are substantially below the recommended 5–10%, spike-ins may be insufficient for these purposes. •Very high duplication rates (Figure 4D): These are expected when working with low RNA input, such as cell-free RNA from plasma. However, extremely high duplication rates (>90%) may indicate insufficient RNA input or over-amplification during library preparation. Very high duplication rates (Figure 4D): These are expected when working with low RNA input, such as cell-free RNA from plasma. However, extremely high duplication rates (>90%) may indicate insufficient RNA input or over-amplification during library preparation. Potential solution Evidence of DNA contamination: •Exclude clear outlier samples showing markedly reduced reads mapping to the expected strand and/or splice junctions, as these samples may not predominantly reflect RNA-derived signal. Exclude clear outlier samples showing markedly reduced reads mapping to the expected strand and/or splice junctions, as these samples may not predominantly reflect RNA-derived signal. •If many samples show similar deviations, this likely indicates an issue during the DNA removal step. In this case, repeat DNase treatment after verifying that the RNA purification kit used is compatible with the chosen DNA removal method.7 If many samples show similar deviations, this likely indicates an issue during the DNA removal step. In this case, repeat DNase treatment after verifying that the RNA purification kit used is compatible with the chosen DNA removal method.7 Low spike-in fractions: •If spike-in counts are low but detectable, proceed with standard library-size normalization for downstream analyses. If spike-in counts are low but detectable, proceed with standard library-size normalization for downstream analyses. •If spike-in reads are absent or extremely low, check spike-in dilution accuracy and confirm correct addition of spike-in RNA during library preparation. If spike-in reads are absent or extremely low, check spike-in dilution accuracy and confirm correct addition of spike-in RNA during library preparation. •For subsequent experiments, consider using a less diluted spike-in mix to ensure adequate representation without excessively consuming sequencing depth. For subsequent experiments, consider using a less diluted spike-in mix to ensure adequate representation without excessively consuming sequencing depth. Very high duplication rates. •If duplication rates are high but comparable across samples, downstream analyses can still be performed, as biological comparisons remain valid under consistent technical conditions. If duplication rates are high but comparable across samples, downstream analyses can still be performed, as biological comparisons remain valid under consistent technical conditions. •If only a subset of samples shows extremely high duplication, consider excluding these samples due to reduced library complexity. If only a subset of samples shows extremely high duplication, consider excluding these samples due to reduced library complexity. •For future experiments, consider increasing the RNA input where possible, reducing the number of PCR cycles, or optimizing library amplification conditions to improve library complexity. For future experiments, consider increasing the RNA input where possible, reducing the number of PCR cycles, or optimizing library amplification conditions to improve library complexity. Resource availability Lead contact Requests for further information should be directed to the lead contact, Annelien Morlion (annelien.morlion@ugent.be). Technical contact Technical questions regarding the execution of this protocol should be directed to the technical contact, Annelien Morlion (annelien.morlion@ugent.be). Materials availability No newly generated materials are associated with this protocol. Data and code availability The accession number for the raw sequencing data (FASTQ files) reported in this paper is EGA: EGAS00001007585 (https://ega-archive.org/studies/EGAS00001007585).1 These data are available under restricted access to comply with data privacy regulations. Access can be requested through EGA, and requests will be evaluated by the ethics committee of Ghent University Hospital (EGA: https://ega-archive.org/datasets/EGAD00001011679). Processed and pseudonymized count files are openly available through Zenodo (Zenodo: https://doi.org/10.5281/zenodo.19113165). All code and instructions for processing the data, as well as code for reproducing the manuscript figures, are also available on Zenodo. Acknowledgments A.D. was supported by a senior postdoctoral fellowship grant from the Research Foundation Flanders (FWO; 1266325N) and by a grant from the Fund Suzanne Duschesne, managed by the King Baudouin Foundation Belgium. A.M. was supported by a predoctoral fellowship grant from the FWO (11C1623N) and a postdoctoral fellowship grant from the Belgian Foundation Against Cancer (2025-085). J.V. was supported by an “opvangmandaat FWO postdoc” fellowship grant from BOF Antwerp University (52065) and a junior postdoctoral fellowship grant from the FWO (12A6F26N). P.D. was funded by the FWO (11H7523N). This work was also supported by GOA BOF Ghent University, the Belgian Foundation Against Cancer, and Kom Op Tegen Kanker (Stand Up To Cancer, the Flemish Cancer Society). The computational resources (Stevin Supercomputer Infrastructure) and services used in this work were provided by the VSC (Flemish Supercomputer Center), funded by Ghent University, FWO, and the Flemish Government – department EWI. The graphical abstract includes public-domain illustrations from NIH BioArt Source (NIAID Visual & Medical Arts, 10/7/2024: BDBlood Vial, bioart.niaid.nih.gov/bioart/52 & Next Gen Sequencer, bioart.niaid.nih.gov/bioart/386). The authors acknowledge financial support from Takara Bio for covering the publication fees of this article. The sponsor had no role in the selection or description of the methodologies presented, and the decision to submit the manuscript for publication was made independently by the authors. Author contributions Conceptualization, A.D.; data curation, A.M. and J.V.; formal analysis, A.M. and J.V.; funding acquisition, A.D.; investigation, K.V.; methodology, A.D. and K.V.; project administration, A.D.; software, A.M. and J.V.; resources, A.D., A.M., J.V., K.V., and P.D.; supervision, A.D., A.M., and J.V.; validation, K.V.; visualization, A.D., A.M., J.V., and K.V.; writing – original draft, A.D., A.M., J.V., and K.V.; writing – review and editing, A.D., A.M., J.V., K.V., and P.D. Declaration of interests The authors declare no competing interests. Footnotes Supplemental information can be found online at https://doi.org/10.1016/j.xpro.2026.104540. Supplemental information File S1. Experimental template for library preparation for total RNA sequencing, related to Section Experimental design of the library preparation, and Section Step-by-step method details, step 7, 12, 19, 48 and 62 How to use this experimental template is described in the sheet ‘HowTo’. File S2. Experimental and analysis template for library quantification for total RNA sequencing, related to Section Library quantification and pooling, step 100, 105, 106, 109 and 111 How to use this experimental and analysis template is described in the sheet ‘HowTo’. References Associated Data Supplementary Materials File S1. Experimental template for library preparation for total RNA sequencing, related to Section Experimental design of the library preparation, and Section Step-by-step method details, step 7, 12, 19, 48 and 62 How to use this experimental template is described in the sheet ‘HowTo’. File S2. Experimental and analysis template for library quantification for total RNA sequencing, related to Section Library quantification and pooling, step 100, 105, 106, 109 and 111 How to use this experimental and analysis template is described in the sheet ‘HowTo’. Data Availability Statement The accession number for the raw sequencing data (FASTQ files) reported in this paper is EGA: EGAS00001007585 (https://ega-archive.org/studies/EGAS00001007585).1 These data are available under restricted access to comply with data privacy regulations. Access can be requested through EGA, and requests will be evaluated by the ethics committee of Ghent University Hospital (EGA: https://ega-archive.org/datasets/EGAD00001011679). Processed and pseudonymized count files are openly available through Zenodo (Zenodo: https://doi.org/10.5281/zenodo.19113165). All code and instructions for processing the data, as well as code for reproducing the manuscript figures, are also available on Zenodo.