Ventricular Tachycardia With a Narrow QRS Complex Authors: Alejandro Manuel López-Pena, Dahyr Olivas-Medina, Alejandro Used-Gavín, Oleksandr Shangutov, Juliana Elices-Teja, Carlos González-Juanatey Published: 2026 ABSTRACT BackgroundVentricular tachycardia (VT) is typically associated with wide QRS complexes; therefore, narrow QRS tachycardia in pacemaker-dependent patients represents a diagnostic challenge.Case SummaryWe report a 79-year-old man with permanent atrial fibrillation and complete atrioventricular block who presented with a regular narrow QRS tachycardia. Device interrogation confirmed ventricular pacing dependence. Electrophysiological studies demonstrated scar-related VT arising from the basal interventricular septum adjacent to the left bundle branch. The tachycardia was characterized by fragmented potentials and slow conduction channels and was entrainable with a short postpacing return cycle, supporting a reentrant mechanism. Targeted ablation rendered VT noninducible. No recurrent arrhythmic events occurred during follow-up.DiscussionVT may present with a narrow QRS morphology in pacemaker-dependent patients when reentrant circuits are located near the His-Purkinje system.Take-Home MessageRecognition of this uncommon mechanism and advanced electrophysiological mapping are essential for accurate diagnosis and targeted ablation. History of Presentation A 79-year-old man with a history of hypertension, dyslipidemia, and permanent atrial fibrillation (AF), anticoagulated with vitamin K antagonists, was referred for sudden-onset palpitations and chest pain.Take-Home Messages•Ventricular tachycardia can rarely present with a nearly narrow QRS complex, even in the context of permanent atrial fibrillation and pacemaker dependence.•Recognition of this uncommon mechanism and advanced electrophysiological mapping are essential for accurate diagnosis and targeted ablation. Take-Home Messages •Ventricular tachycardia can rarely present with a nearly narrow QRS complex, even in the context of permanent atrial fibrillation and pacemaker dependence.•Recognition of this uncommon mechanism and advanced electrophysiological mapping are essential for accurate diagnosis and targeted ablation. •Ventricular tachycardia can rarely present with a nearly narrow QRS complex, even in the context of permanent atrial fibrillation and pacemaker dependence. Ventricular tachycardia can rarely present with a nearly narrow QRS complex, even in the context of permanent atrial fibrillation and pacemaker dependence. •Recognition of this uncommon mechanism and advanced electrophysiological mapping are essential for accurate diagnosis and targeted ablation. Recognition of this uncommon mechanism and advanced electrophysiological mapping are essential for accurate diagnosis and targeted ablation. On arrival at the emergency department, he was tachycardic with borderline hemodynamic tolerance (systolic blood pressure: 90 mm Hg) but preserved peripheral perfusion. Past Medical History Four years earlier, he had received a single-chamber pacemaker for AF with complete atrioventricular (AV) block, with near-complete ventricular pacing. The device was functioning normally. Differential Diagnosis The differential diagnosis included ventricular tachycardia (VT), supraventricular tachycardia with intrinsic AV conduction, idiopathic conduction system–dependent tachycardias including fascicular VT, and nodoventricular accessory pathway–mediated tachycardias. Investigations The electrocardiogram (ECG) showed a regular narrow QRS tachycardia at 180 beats/min (Figure 1A). Pharmacologic cardioversion with amiodarone was successful, and a subsequent ECG demonstrated AF with ventricular pacing dependence (Figure 1B).Figure 1Patient's Electrocardiograms(A) Electrocardiogram on arrival at the emergency department showing a regular narrow-borderline QRS tachycardia (QRS duration: 120 milliseconds) at 180 beats/min, with positive values in lead II and negative values in lead III, with precordial transition in V2. (B) Electrocardiogram after cardioversion demonstrating atrial fibrillation with ventricular pacing dependence. The paced QRS complex shows an R-wave in lead V1, with a left bundle branch block–like morphology in the remaining precordial leads (QRS duration: 162 milliseconds). Patient's Electrocardiograms (A) Electrocardiogram on arrival at the emergency department showing a regular narrow-borderline QRS tachycardia (QRS duration: 120 milliseconds) at 180 beats/min, with positive values in lead II and negative values in lead III, with precordial transition in V2. (B) Electrocardiogram after cardioversion demonstrating atrial fibrillation with ventricular pacing dependence. The paced QRS complex shows an R-wave in lead V1, with a left bundle branch block–like morphology in the remaining precordial leads (QRS duration: 162 milliseconds). Pacemaker interrogation revealed VVIR programming (lower rate: 60 beats/min, maximum tracking rate: 130 beats/min), absence of an intrinsic escape rhythm, and nearly 100% ventricular pacing. An episode of sustained tachycardia with a cycle length of 320 milliseconds lasting over 1 hour was documented. Transthoracic echocardiography showed mildly reduced left ventricular ejection fraction without other structural abnormalities. Management An electrophysiological study with right ventricular electroanatomical mapping identified a scar extending from the free wall to the basal septum, consistent with the suspected tachycardia origin, with fragmented and early diastolic potentials. As clinical tachycardia was noninducible, substrate modification of the basal septum was performed, abolishing these potentials, and an implantable cardioverter-defibrillator with left bundle branch pacing was implanted for secondary prevention. The patient was later readmitted with an arrhythmic storm due to recurrent monomorphic VT effectively treated by the implantable cardioverter-defibrillator. ECG documentation revealed recurrence of the same regular narrow QRS tachycardia, prompting a second electrophysiological study via a retroaortic left ventricular approach (Figures 2A and 2B). VT was induced, and a slow conduction channel with late diastolic potentials was identified in the basal posteroseptal region near the proximal left bundle branch. During the arrhythmia, more than 90% of the tachycardia cycle length was recorded in this region, and entrainment demonstrated a short postpacing return cycle, supporting a reentrant mechanism. Targeted ablation terminated the tachycardia and rendered it noninducible.Figure 2Electroanatomical Mapping of the Left Ventricle During the Second Procedure(A) Activation map and (B) voltage map obtained during ventricular tachycardia (VT) using a retroaortic approach. The activation map identifies a slow conduction channel in the basal posteroseptal region, adjacent to the proximal left bundle branch, whereas the voltage map demonstrates a corresponding low-voltage area. Radiofrequency ablation targeting this region resulted in VT termination and subsequent noninducibility. The aorta (AO) and interventricular septum (IVS) are shown as anatomical landmarks. Electroanatomical Mapping of the Left Ventricle During the Second Procedure (A) Activation map and (B) voltage map obtained during ventricular tachycardia (VT) using a retroaortic approach. The activation map identifies a slow conduction channel in the basal posteroseptal region, adjacent to the proximal left bundle branch, whereas the voltage map demonstrates a corresponding low-voltage area. Radiofrequency ablation targeting this region resulted in VT termination and subsequent noninducibility. The aorta (AO) and interventricular septum (IVS) are shown as anatomical landmarks. Outcome and Follow-Up At more than 6 months of clinical and device follow-up, no further arrhythmic events have been recorded. Discussion VT is typically associated with wide QRS complexes; therefore, the occurrence of a regular tachycardia with a narrow or borderline QRS morphology in a patient with complete ventricular pacing dependence represents a major diagnostic challenge. In this setting, supraventricular tachycardia with intrinsic AV conduction—such as organization of AF into atypical atrial flutter—is often initially suspected. In the present case, however, the patient was completely pacemaker-dependent, as confirmed by device interrogation and prior follow-up, with no evidence of intrinsic AV conduction. Furthermore, VT was documented during the electrophysiological study while the patient remained in AF, effectively excluding a supraventricular mechanism. Idiopathic conduction system–dependent tachycardias, including fascicular VT, were also considered. Nevertheless, electroanatomical mapping revealed a heterogeneous scar in the basal posteroseptal region of the left ventricle, adjacent to the proximal left bundle branch. A slow conduction channel with late diastolic potentials was identified, and the tachycardia was entrainable, supporting a scar-mediated reentrant ventricular mechanism rather than enhanced automatism or a conduction system–dependent circuit occurring in a structurally normal myocardium. The close proximity of the reentrant circuit to the His-Purkinje system explains the narrow QRS morphology during VT, allowing rapid ventricular activation through the conduction system. Although rarely reported, this mechanism may lead to misdiagnosis, particularly in patients with ventricular pacing devices. Much less frequently, true nodoventricular accessory pathways have been described, which can generate regular tachycardias with narrow QRS complexes even in the context of complete AV block. However, these entities are exceptional and, in our case, would not explain the electroanatomical findings or the response to ablation targeting the ventricular substrate.1 Conclusions This case highlights a rare form of reentrant VT arising from the left basal septum and closely related to the conduction system, capable of presenting with a narrow QRS complex. Recognition of this entity is essential to avoid diagnostic and therapeutic errors and underscores the value of advanced electrophysiological mapping to guide targeted ablation, even in pacemaker-dependent patients.Visual SummaryNarrow QRS Ventricular Tachycardia in a Pacemaker-Dependent Patient Narrow QRS Ventricular Tachycardia in a Pacemaker-Dependent Patient Funding Support and Author Disclosures The authors have reported that they have no relationships relevant to the contents of this paper to disclose.