Alternating Bundle Branch Block Despite a Patent Stent in Late-Presenting Extensive Anterior STEMI Authors: Mochamad Y Alsagaff, Cornelia Ghea, Hendri Susilo, Elisabeth Sekaringtyas Medistya Putri Published: 2026 ABSTRACT AbstractBackgroundAlternating bundle branch block (ABBB) is a rare but high-risk marker of advanced infra-Hisian disease and impending high-grade atrioventricular (AV) block in anterior ST-segment elevation myocardial infarction (STEMI).Case SummaryA 39-year-old male smoker presented 19 hours after chest pain onset with extensive anterior STEMI and ABBB. Ostial left anterior descending artery occlusion was treated with overlapping drug-eluting stents, achieving TIMI flow grade III. Despite patent stents, he developed delayed complete AV block. Temporary transvenous pacing restored hemodynamic stability, and AV conduction recovered within 24 hours.DiscussionSeptal injury, edema, microvascular obstruction, or reperfusion injury can destabilize His-Purkinje conduction despite the presence of open epicardial arteries.Take-Home MessageABBB warrants continuous monitoring and pacing readiness, even when angiography appears reassuring.Key words: alternating bundle branch block, complete atrioventricular block, STEMI Alternating bundle branch block (ABBB) is a rare, high-risk marker of advanced infra-Hisian disease in anterior ST-segment elevation myocardial infarction (STEMI). It may precede delayed high-grade atrioventricular (AV) block despite successful primary percutaneous coronary intervention (PCI). Take-Home Message •Alternating bundle branch block warrants continuous monitoring and pacing readiness, even when angiography appears reassuring. Alternating bundle branch block warrants continuous monitoring and pacing readiness, even when angiography appears reassuring. History of Presentation A 39-year-old man, an active smoker, presented with ischemic chest pain that began 19 hours before admission. The initial electrocardiogram showed extensive anterior ST-segment elevation myocardial infarction (STEMI) with a right bundle branch block (RBBB) pattern. High-sensitivity cardiac troponin I was 3,718 ng/L (reference: <20 ng/L). On arrival, the RBBB resolved while ST-segment elevation persisted, raising concern for evolving conduction system injury. He was hemodynamically stable. Differential Diagnosis Extensive anterior STEMI from an ostial left anterior descending artery (LAD) occlusion with dynamic bundle branch block patterns was suspected, with risk of high-grade AV block. After recurrent arrest post-PCI, stent thrombosis/reocclusion and mechanical complications were considered; repeat angiography confirmed patent stents, favoring primary electrical instability. Investigations Serial electrocardiography showed RBBB, then RBBB resolution with persistent ST-segment elevation, then new left bundle branch block after PCI, consistent with ABBB (Figures 1A to 1C). Rhythm remained sinus (P waves preceding each QRS), distinguishing it from accelerated idioventricular rhythm. Angiography showed total ostial LAD occlusion (Figure 1D). Findings on Serial Electrocardiography and Angiography (A) Initial electrocardiogram showed extensive anterior STEMI with RBBB pattern, then (B) persistent STEMI with RBBB resolution. (C) Electrocardiogram after PCI showed new LBBB, consistent with ABBB. (D) Angiography showed ostial left anterior descending artery occlusion before PCI and (E) TIMI flow grade III after PCI. (F) Angiography after 12 hours showed patent stents, with no thrombosis. ABBB = alternating bundle branch block; LBBB = left bundle branch block; PCI = percutaneous coronary intervention; RBBB = right bundle branch block; STEMI = ST-segment elevation myocardial infarction. Management Dual antiplatelet therapy was given before PCI. Two overlapping drug-eluting stents were deployed, with final TIMI flow grade III (Figure 1E). Temporary pacing was not performed because the patient was stable. Twelve hours later, telemetry showed sinus bradycardia progressing to complete AV block with an unstable escape rhythm and recurrent cardiac arrest; repeat angiography confirmed patent stents (Figure 1F). A temporary transvenous pacemaker stabilized the rhythm, and AV conduction recovered within 24 hours. Outcome and Follow-Up AV conduction gradually recovered within 24 hours after temporary pacing. The patient remained clinically stable in the intensive care unit and was discharged in good condition. Discussion This case underscores 4 concepts: dynamic bundle branch block patterns in extensive anterior STEMI may reflect septal conduction system injury; successful epicardial reperfusion does not indicate microvascular recovery; tissue ischemia or reperfusion injury may precipitate delayed AV block; and ABBB in acute myocardial infarction should prompt prolonged monitoring and a low threshold for temporary pacing.1,2 The right bundle branch is supplied by septal perforators from the proximal LAD, explaining early RBBB with proximal/ostial LAD occlusion, whereas deeper septal involvement may affect the left bundle and progress to AV block. Clinically, ABBB should prompt prolonged monitoring and a low threshold for temporary pacing; recurrent arrest or AV block after PCI warrants evaluation for recurrent ischemia with pacing support.1,3 Conclusions In late-presenting extensive anterior STEMI, a patent stent and TIMI flow grade III may not exclude life-threatening electrical instability. ABBB despite a patent stent signals advanced infra-Hisian involvement and warrants close monitoring and early pacing readiness. Data Availability The data supporting the findings of this study are available from the corresponding author upon reasonable request. Funding Support and Author Disclosures The authors have reported that they have no relationships relevant to the contents of this paper to disclose. Visual SummaryTimeline of the CaseTimeEventsDay 1 (presentation)A 39-year-old male smoker presented 19 hours after chest pain. Initial ECG demonstrated extensive anterior STEMI with an RBBB pattern.ArrivalRepeat ECG showed resolution of the RBBB while persistent anterior ST-segment elevation remained, suggesting evolving septal conduction system injury.Catheterization laboratoryCoronary angiography demonstrated total ostial LAD occlusion. Primary PCI was performed with implantation of 2 overlapping drug-eluting stents, achieving final TIMI flow grade III.Immediately after PCIPost-PCI ECG showed new LBBB, establishing ABBB in the setting of extensive anterior STEMI. Rhythm remained sinus, arguing against accelerated idioventricular rhythm.12 Hours after PCITelemetry showed sinus bradycardia progressing to complete AV block with an unstable escape rhythm, followed by recurrent cardiac arrest.Repeat angiographyUrgent repeat coronary angiography confirmed patent LAD stents without thrombosis or reocclusion, favoring conduction-system injury and electrical instability rather than recurrent epicardial ischemia.Day 2Temporary transvenous pacing restored electrical and hemodynamic stability. AV conduction recovered gradually within 24 hours.Day 4The patient remained clinically stable in the ICU and was discharged in good condition. This case demonstrates that ABBB despite a patent stent is a high-risk warning sign for delayed complete AV block.ABBB = alternating bundle branch block; AV = atrioventricular; ECG = electrocardiogram; ICU = intensive care unit; LAD = left anterior descending artery; LBBB = left bundle branch block; PCI = percutaneous coronary intervention; RBBB = right bundle branch block; STEMI = ST-segment elevation myocardial infarction. Timeline of the Case ABBB = alternating bundle branch block; AV = atrioventricular; ECG = electrocardiogram; ICU = intensive care unit; LAD = left anterior descending artery; LBBB = left bundle branch block; PCI = percutaneous coronary intervention; RBBB = right bundle branch block; STEMI = ST-segment elevation myocardial infarction. Footnotes The authors attest they are in compliance with human studies committees and animal welfare regulations of the authors’ institutions and Food and Drug Administration guidelines, including patient consent where appropriate. For more information, visit the Author Center. References Associated Data Data Availability Statement The data supporting the findings of this study are available from the corresponding author upon reasonable request.