Characterization of indoor air quality in logistics warehouses in France: environmental measurements and worker exposure assessments Authors: Laurence Robert, Romain Guichard, Jennifer Klingler Published: 2026 ABSTRACT AbstractThe objective of this study was to provide data on the concentrations of volatile organic compounds (VOCs), aldehydes, and total dust levels in logistics warehouses, in order to identify substances of concern for indoor air quality (IAQ) and worker exposure in these buildings. Seven warehouses were selected based on the diversity of stored products. Active sampling of VOCs, aldehydes and particles was carried out over the course of 1 d, at 3 to 5 locations within each building, as well as outdoors. Among the 7 warehouses investigated, tire logistics centers were found to have the poorest IAQ, as reflected by significantly higher concentrations of total VOCs compared with the other warehouses, ranging from 1,079 to 3,747 µg/m3 toluene equivalent, compared with 166 to 470 µg/m3 in the other sites. Based on the total VOC concentration, more in-depth investigations were conducted in the working environment involving the most degraded IAQ, namely 1 of the 2 tire warehouses. These additional analyses, including emission cell degassing of a tire sample, a detailed air characterization, and personal exposure measurements, revealed the presence of several CMR substances in these working environments, such as MIBK and aniline. Occupational exposure of French workers in logistics warehouses to chemical substances is poorly documented. This study provides a dataset on the nature and concentrations of various compounds (VOCs, aldehydes, and total dust) detected in this type of work environment. The study highlights the heterogeneity of indoor air quality, with air quality depending on the type of stored products and being significantly poorer in tire storage areas compared with other environments where stored products are packaged and wrapped. These results represent a first step towards assessing worker exposure in such environments. Introduction In 2023, more than 3.4 million full-time equivalent workers were employed in the retail and logistics sector in France (INSEE, 2025). For employees working in the nonfood sectors, exposure to chemical risks can often go unnoticed due to a lack of awareness. Since these workers do not handle chemicals directly but rather everyday consumer goods, few employees, employers, or even occupational health professionals may consider the potential for chemical exposure in these settings. However, volatile organic compounds (VOCs) emitted by stored consumer products contribute to the deterioration of indoor air quality (IAQ) in workplaces. Loh et al. (2006) and Nirlo et al. (2014) demonstrated the impact of products sold on the levels of VOC concentrations measured in the work environment of retail employees. Indeed, while several studies have specifically investigated IAQ in retail stores (Loh et al. 2006; Eklund et al. 2008; Nirlo et al. 2014; Zaatari et al. 2014; Chan et al. 2015; Shang et al. 2016; Robert et al. 2021a, 2021b; Baptista et al. 2022), very few have focused on logistics warehouses. After conducting measurements in 10 retail stores throughout France, Robert et al. (2021b) revealed the presence of a large variety of VOCs in the indoor air of these stores, including carcinogenic, mutagenic, and reprotoxic (CMR) substances, with concentrations that varied significantly depending on the types of products being sold. Toluene and formaldehyde were ubiquitous, reaching concentrations of up to 252 and 53 µg/m3, respectively. An analysis comparing IAQ between sales areas and storage zones in 5 of the 10 stores studied (Robert et al. 2021a) revealed that air quality in storage areas was significantly poorer than in sales areas. For example, in the textile store examined in this study, total VOCs concentrations were found to be nearly twelve times higher in the storage areas compared with the sales zones. Measurements taken in the sales area of the textile store were supported by Furst et al. (2025) from a clothing shop in Portugal and by studies in underground retail spaces in South Korea (Kim et al. 2024), but these studies did not examine the storage zones. In the sports equipment store studied by Robert et al. (2021a, 2021b), toluene concentrations were over 60 times higher in the storage area compared with the sales area. IAQ in logistics warehouses is poorly documented, despite these workplaces being large storage areas with a constant influx of new products. Moreover, several characteristics of storage areas may contribute to poor air quality: overcrowding with new products arriving daily in containers, poor or nonexistent ventilation, and uncontrolled indoor temperatures. To reduce energy consumption, storage zones are typically not heated or ventilated. Although temperatures that are too low or too high affect thermal comfort, elevated temperatures further promote the off-gassing of VOCs from new goods. Indeed, environmental factors such as temperature, humidity, and ventilation characteristics significantly influence emissions (Haghighat and De Bellis 1998; Kelly et al. 1999; Ho et al. 2011; Caron et al. 2020). Recent advances in warehouse design include numerical simulations aimed at controlling temperature increases to promote better air quality (Terziev and Ivanov 2024). These observations indicate that IAQ degradation is possible in storage spaces, highlighting the importance of this issue for the prevention of workers’ chemical exposure. Also in this context, to better understand the exposure of employees working in logistics warehouses and to provide appropriate preventive solutions, the IAQ was characterized in logistics warehouses, and additional measurements on employees were conducted. Materials and methods Description of the warehouses Seven logistics warehouses were selected based on the type of goods stored, in order to capture the widest possible diversity. Each of the selected warehouses is located in France. The authors relied on the French occupational prevention network to identify and select the warehouses included in the study, with particular care taken to ensure diversity in both the types of products stored and the storage conditions (ie packaged versus unpackaged products). Seasonality was not used as a primary selection criterion for these measurement campaigns. Two warehouses store tires, 2 are dedicated to furniture and home decoration products, 1 store large building equipment such as doors, staircases, windows, or bathtubs, and another is used by a major DIY retail chain. The final warehouse stores a wide variety of miscellaneous items for the home, garden, indoor and outdoor decoration, toys, etc., serving as a distribution hub for an online retail platform. In 5 of the 7 warehouses, items are stored on metal structures with wooden pallets, while in the 2 tire warehouses, the tires are placed on fully metallic racks. In the same way, the products are generally packaged in cardboard boxes or plastic film, except for the tires and building equipment. Finally, 2 warehouses were monitored in winter and 5 in summer. However, the influence of seasonal effects has been investigated in a previous study conducted in comparable occupational environments like storage areas of retail stores selling sporting goods (Robert et al. 2021a). In this study, seasonal variations were shown to influence indoor temperature, which in turn affected the emission of chemical compounds from stored products. Specifically, increases in concentration by factors ranging from 4.0 to 5.2 for formaldehyde and from 3.6 to 6.2 for total VOCs were observed between winter and summer, corresponding to indoor temperature increases of from 11.8 to 14.2 °C. All warehouses are built similarly, featuring a lightweight metal structure combined with fiberglass-type insulation. The surface area of each site varies according to the number of storage units in use, with each unit covering approximately 6,000 m2 and featuring a ceiling height of about 12 m. During the winter season, none of the warehouses are heated, and only 1 facility, which stores building equipment, is fitted with a ventilation system. The system operates via air extraction. Each section of the warehouse includes an 8,000 m3/h air extractor, resulting in an air exchange rate of 0.12 air volumes per hour. Typically, these facilities are ventilated by opening the loading bay doors when containers carrying storage goods are unloaded. Building sizes range from 18,000 to 72,000 m2. Table 1 presents the main characteristics of the instrumented sites. Table 1Main characteristics of the warehouses.CharacteristicsE1E2E3E4E5E6E7Stored productsTiresFurniture and decorationFurniture and decorationBuilding equipmentVarious products for online salesTiresDIY productsFrench department number of warehouse location13133841412626Number of 6,000 m2 cells31241241010Storage area [m2]18,00072,00024,00072,00024,00060,00060,000Mechanical ventilationNoNoNoYesNoNoNoMonth and year of investigation12/202212/202203/202306/202309/202306/202406/2024Number of indoor measurement points5545443 Main characteristics of the warehouses. Measurement strategy In each warehouse, a measurement campaign was conducted on a single working day during typical working hours, generally between 7 AM and 6 PM. The objective of the measurement campaigns was to characterize air quality at 5 indoor locations and 1 outdoor reference point. However, in some warehouses, it was not possible to install all planned sampling points due to access restrictions. In addition, technical issues prevented the use of certain measurements (eg sampling pump failure, displacement of monitoring equipment by the warehouse staff). These constraints further highlight the practical challenges associated with acquiring reliable exposure data in such occupational environments, which likely contributes to the limited amount of available data reported in the literature. This selection of measurement points nonetheless allowed us to document the spatial variability within the same structure in terms of the type and concentration of VOCs, aldehydes, and particles. For comparative purposes, 1 outdoor measurement was consistently carried out. Sampling and analyses All data loggers and air sampling systems were placed in wire mesh enclosures at a height of 1.4 m above the floor. These enclosures were specifically designed to prevent workers from interfering with the measurements. ARANET 4 data loggers from TH Instrument were used to monitor air temperature, relative humidity and carbon dioxide concentrations in real time, with data transmitted every minute. Temperature measurements were accurate to ±0.3 °C within the 0 to 50 °C range. Humidity measurement were accurate to +/− 3% within the 0 to 85% range. For carbon dioxide (CO2) levels measured by a nondispersive infrared cell, the accuracy was 3% of the reading for concentrations under 2,000 ppmv within the 0 to 9,999 ppmv range. First-stage analysis: VOCs, aldehydes, and particulate matter Sampling of VOCs was performed with Tenax TA adsorbent tubes at a flow rate between 50 mL/min over at least 6 h, followed by thermal desorption and gas chromatography analysis in compliance with ISO 16000-6 (2021). In the initial phase, the analysis focused exclusively on the following volatile organic compounds: toluene, o-xylene, m/p-xylenes, styrene, and α-pinene. The concentrations are reported in μg/m3 of air, with a 30% uncertainty on the measured values. For all VOCs, the quantification limit (LOQ) is set at 0.1 μg/m3. Additionally, the analysis provided the total VOC concentration expressed as toluene equivalent for VOCs eluted between 5 and 20 carbon atoms. The results will be presented as average concentrations per chemical compound for each warehouse, calculated across all available measurement locations, together with the associated ranges of variation. These values will be compared with identify potential occupational exposure, using a total VOC concentration threshold of 1,000 µg/m3 expressed as toluene equivalent. When this criterion is exceeded, a more detailed investigation is conducted in the most impacted warehouse to identify the determinants of pollution and to assess workers’ exposure according to their specific tasks. Sampling of aldehydes was performed with DNPH cartridges, operating at a flow rate of 300 to 400 ml/min over a minimum duration of 6 h. The cartridges were then analyzed using high-performance liquid chromatography (HPLC) in accordance with ISO 16000-3 (2022). Three aldehydes were primarily targeted: formaldehyde, acetaldehyde, and hexanal. Concentrations are given in μg/m3 of air, with an uncertainty margin of 25% on the stated value. The limit of quantification (LOQ) is 0.4 μg/m3 for these 3 aldehydes. Particles were measured using a LIGHTHOUSE optical particle counter, model Handheld 3016-IAQ. Particle measurement is distributed across 6 channels ranging from 0.3 to 25 µm and is automatically converted into mass concentration in µg/m3. The counting efficiency is 50% for 0.3 μm particles and reaches 100% for particles above 0.45 μm. Only total dust concentration results will be reported. Following the initial results in tire warehouses, 3 additional analyses were conducted in these environments to better understand employee exposure: a characterization of VOCs emitted by tires after degassing a sample in an emission cell, a more detailed analysis of air compounds, and exposure measurements on employees. Tire degassing protocol Two specimens measuring 2 cm by 10 cm were taken from the same new tire purchased commercially. They were placed in an emission cell swept with an inert gas at a set temperature. Two temperatures were selected for degassing: 30 and 60 °C. 30 °C represents a temperature that can be observed indoors during periods of intense summer heat. 60 °C is an extreme temperature but 1 that may be reached inside containers left in the sun awaiting unloading in the warehouse (Singh et al. 2012). In addition, this elevated temperature facilitates the degassing of the greatest amount of VOCs and offers a more complete profile of tire emissions. For these tests, samples were taken on TENAX tubes at the emission chamber outlet to identify the compounds likely to be emitted. The concentrations are given in µg/g of tire material. These tests were conducted by the TERA Environment laboratory, accredited by COFRAC for these analyses according to the ISO 16017-1 (2000) standard. Further analysis of VOCs in the E6 tire warehouse Six more compounds were measured in this warehouse, in addition to those from the initial testing: MIBK, cyclohexanone, aniline, benzothiazole, 5-methyl-2-hexanone and ethanol. MIBK was collected on a DNPH cartridge, and the remaining compounds (excluding ethanol) were trapped on TENAX tubes. These sampling conditions for both compound groups matched those previously outlined in the section on first-stage measurements. An additional sample was collected on an activated charcoal tube over 6 h at an average flow rate of 67 mL/min to capture ethanol. Employee exposure in the E6 tire warehouse In this warehouse, 3 employees were equipped in order to assess their exposure. It was decided to equip 3 employees simultaneously, each performing different tasks. A first employee, referred to as “W1”, is responsible for unloading a container and works inside it to manually remove the tires. A second employee, referred to as “W2”, receives the tires at the exit of the container, at the end of a long conveyor belt, and stores them on a mobile rack. A third employee, referred to as “W3”, moves throughout the entire warehouse to retrieve or store tires using an electric forklift truck. All 3 workers were equipped with backpacks housing air sampling pumps. Positioned at shoulder level and directed towards the face, the sampling supports were placed near the respiratory zone. The flow rates of the pumps, the type of sampling media along with the targeted compounds, as well as the sampling duration characteristic of a work task for each of the 3 employees, are presented in Table S1. Results and discussion Indoor environmental parameters Table S2 shows the average and the minimum/maximum variations of air temperature, as well as the average and minimum/maximum CO2 concentration in all 7 warehouses of the panel on the day of the measurements. To allow comparison, the matching values for outdoor air are provided. The temperatures in the first 2 warehouses, measured in winter, are markedly lower than in the others, recorded at 12.8 and 15.7 °C. For the other 5 warehouses, where measurements were carried out during spring or summer, average temperatures range between 18.5 and 24.3 °C. The average relative humidity showed limited variability across the different warehouses and measurement periods, ranging from 42.5% to 49.4%, with the exception of warehouse E5, where measurements were conducted on a stormy day with a higher outdoor relative humidity of 71%. Under these temperature and humidity conditions, no clear indication of summer thermal discomfort for warehouse workers can be inferred, although a comprehensive assessment of thermal comfort would require additional parameters, including workers’ metabolic rate, clothing insulation, air velocity, and mean radiant temperature. The absence of thermal discomfort does not apply to workers unloading shipping containers. During summer periods, container internal temperatures can reach very high values potentially up to 60 °C (Singh et al. 2012). Combined with intense radiant heat from container walls and high physical workload, these conditions may lead to situations of significant thermal stress. Regarding CO2 concentrations, there is a clear correlation between the corresponding indoor and outdoor values. Considering the size of these workspaces, the presence of employees does not affect indoor CO2 levels through their respiration. For warehouse E3, an abnormally elevated outdoor CO2 concentration of 560 ppmv was recorded, resulting from the placement of the external sensor near a heavily trafficked motorway on the measurement day. Concentrations of aldehydes, VOCs and dust measured in preliminary analysis Table 2 presents the average and minimum/maximum concentrations of VOCs and aldehydes. These results are displayed using boxplots for formaldehyde concentrations in Fig. 1 and for total VOC concentrations in Fig. 2. Among the 3 quantified aldehydes, formaldehyde averages range from 3.5 to 32.6 µg/m3, with a maximum local value of 44.5 µg/m3 observed in warehouse E4, which stores large construction equipment such as doors, stairs, windows, and bathtubs (Fig. 1) while the maximum mean concentration was obtained in warehouse E5. These concentrations may be explained by the larger amount of wood-based materials, varnishes, and MDF present, as well as the highest indoor temperature recorded (24.3 °C) (Caron et al. 2020; Garras et al. 2021). It is also observed that in the 2 tire storage warehouses E1 and E6, the formaldehyde concentrations are clearly the lowest, at 3.5 and 5.5 µg/m3, and close to the average outdoor level of 2 µg/m3. The average formaldehyde concentrations in this selection of warehouses, from 3.5 to 32.6 µg/m3, are in line with those recorded in retail stores by Robert et al. (2021a, 2021b), which ranged from 8 to 28 µg/m3 using the same measurement methodology. Acetaldehyde concentrations range on average from 1.8 to 20 µg/m3, with a maximum value of 33.2 µg/m3. Hexanal, for its part, varies on average between 9 and 19.5 µg/m3 and was not found in the 2 warehouses storing tires, E1 and E6. Finally, all the measured concentrations are below the occupational exposure limits provided by the French National Research and Safety Institute (INRS). As a reminder, for formaldehyde, which is classified as a CMR (Carcinogenic, Mutagenic, or Reprotoxic) substance, the occupational exposure limit (OEL) is 625 μg/m3 for an 8-h exposure (INRS, 2025). Furthermore, none of the concentrations exceeded the IAQ guideline set by the French Agency for Food, Environmental and Occupational Health & Safety (ANSES, 2024), which is 100 μg/m3 for short-term exposure (30 min) to formaldehyde. Distribution of formaldehyde concentrations per warehouse expressed in µg/m3. Distribution of total VOC concentrations per warehouse expressed in µg/m3 toluene equivalent. Table 2Indoor concentrations of aldehydes and VOCs (µg/m3) and total VOCs (µg/m3 toluene equivalent) by warehouse type (average concentration in bold; minimum and maximum in brackets).E1E2E3E4E5E6E7OutdoorNumber of measurements55454337CompoundCAS No.Formaldehyde50-00-0 5.5 [3.5; 9.2] 8.6 [7.7; 10,1] 11.9 [6.2; 14.9] 28.6 [13.5; 44.5] 32.6 [27.2; 36.4] 3.5 [2.1; 5.6] 17.8 [14.5; 23.1] 2 [