Impact of Cardiopulmonary Resuscitation Health Care Workers' Physical Health Parameters on Cardiopulmonary Resuscitation Performance Quality in Simulated Manikin-Based Settings—A Systematic Review Authors: Prabha Prakash, Kirtana R Nayak, Abraham S Babu, Elsa S Devi, Souvik Chaudhuri, Dinker R Pai, Vimal Krishnan S Published: 2026 ABSTRACT AbstractObjectivesThe physical fitness of health care workers also influences the quality of cardiopulmonary resuscitation (CPR). With the recent conceptualization of “pit-crew” in hospitals to ensure sustained, seamless, high-quality CPR, the physical fitness parameters of CPR health care workers that affect CPR quality must be systematically studied. This systematic review aimed to synthesize findings from the current literature on the physical health parameters of CPR health care workers that are essential to ensuring high-quality CPR.MethodsPubMed, Scopus, and the Cochrane databases were reviewed to identify relevant articles published in English from inception to February 2025. Studies were included if they reported any physical health parameter of CPR health care workers and their association with high-quality CPR, including chest compression rate, depth, timing, or overall CPR quality. The risk of bias was assessed using the Joanna Briggs Institute critical appraisal tool by 2 independent reviewers.ResultsAfter screening of 11,895 articles, 22 studies published between 2002 and 2024 were included, with 2492 CPR participants in manikin studies. Age, gender, height, weight, body mass index, physical exercise frequency, handgrip or upper-body strength, anaerobic power, maximum heart rate during CPR, muscle strength, fatigue or endurance, body composition, and ventilation threshold were various parameters that were found to be significantly associated with high-quality CPR. Due to differences in the presentation of physical fitness parameters across the studies, a meta-analysis could not be carried out as planned.ConclusionPhysical health and fitness parameters of CPR health care workers are crucial to ensure high-quality CPR. Achieving adequate depth and sustained frequency of chest compressions requires both strength and endurance among CPR health care workers.Keywords: cardiopulmonary resuscitation, physical parameter, high-quality cardiopulmonary resuscitation (CPR) Introduction Background High-quality chest compressions include compressions at a rate of 100 to 120 per min, with at least 5 cm depth in adults, and complete chest recoil.1 A chest compression fraction (CCF) >80% and at least 60% is associated with higher chances of return of spontaneous circulation.2,3 High-quality chest compressions are related to the physical health parameters of the cardiopulmonary resuscitation (CPR) health care workers.4, 5, 6 Literature review depicts multiple health parameters for evaluating the physical health of CPR health care workers, with mixed results.4, 5, 6 Importance Contemporary resuscitation guidelines mainly focus on process-of-care metrics, training strategies, feedback, and team dynamics to ensure seamless CPR delivery.2,3 Despite these advances, CPR is an inherently physically demanding task, and emerging evidence highlights that rescuer fatigue and their physical health parameters significantly influence the ability to sustain high-quality chest compressions even among trained health-care workers.4, 5, 6 Manikin simulation-based studies assessed the association between high-quality CPR and health care workers' specific health parameters, like body composition consisting of muscle mass (MM), fat mass (FM), fat-free mass (FFM), and total body water (TBW), anthropometry, upper and lower back muscular strength, endurance, and cardiorespiratory fitness.5, 6, 7, 8 These parameters may independently affect compression rate, compression depth, recoil, and fatigue resistance.5, 6, 7, 8 However, these findings were inconsistently distributed across individual studies and isolated health variables and lacked a unified composite framework.4, 5, 6, 7, 8 Certainly, there has been no contemporary systematic synthesis of this evidence to assess how the physical health parameter of CPR health care workers' influences CPR quality independent of training, knowledge, or technical skill. This gap is significantly relevant as CPR training and the team-based resuscitation model assume uniform physical capability among health care workers, an assumption that may not hold in real-world settings. The ability to deliver a sustained high-quality CPR depends on the strength and endurance of the CPR health care workers.7 Optimal constitution of CPR teams is quintessential for ensuring better in-hospital cardiac arrest (IHCA) outcomes.9 The incorporation of CPR provider health parameters is an important aspect that hospitals can consider while constituting CPR provider teams.1 However, there is an evidence gap regarding the specific health parameters of CPR health care workers that should be evaluated to ensure that the CPR teams in hospitals can provide sustained high-quality CPR. Addressing this gap will be essential to provide evidence for future CPR workforce preparedness strategies and enhance the reliability and effectiveness of high-quality CPR delivery in-hospital settings. Goal of This Investigation This systematic review aimed to synthesize evidence on the specific physical health parameters of CPR health care workers that are essential for ensuring high-quality CPR. Methods Study Design and Registration This systematic review (SR) was registered with PROSPERO (registration no. CRD42024578517). The Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines were followed for reporting this systematic review.10 Results were synthesized narratively in accordance with the Synthesis Without Meta-analysis guidelines, as statistical pooling is not possible Supplementary Appendix 6.11 Our specific research question was which specific physical health parameters of CPR health care workers are associated with the delivery of high-quality CPR? The physical health parameters included any parameters reported in the studies related to anthropometric measurements, physical exercise activity, muscle strength and fatigue, body composition, and cardiorespiratory parameters of CPR providers. Search Strategy We searched 3 databases—PubMed, Scopus, and Cochrane—for an extensive literature search with the search string using Boolean operators “AND” and “OR” with MeSH terms “(CPR) OR (cardiopulmonary resuscitation) OR (ACLS) OR (advanced cardiac life support) OR (BLS) OR (basic life support) OR (chest compressions) OR (code blue resuscitation) OR (cardiac arrest resuscitation) AND (rescuer) OR (CPR provider) OR (code blue team) OR (CPR team) OR (resuscitation team) OR (resuscitation team member) OR (healthcare provider) OR (BLS provider) OR (ACLS provider) AND (rescuer health) OR (provider health) OR (rescuer fatigue) OR (provider fatigue) OR (rescuer physical parameters) OR (provider physical parameters) OR (rescuer health parameters) OR (rescuer health condition) OR (rescuer fitness) OR (provider fitness) AND (CPR quality) OR (chest compression quality) OR (high quality CPR.” The Population, Exposure, Comparator, and Outcome (PECO) format for our review was also provided, along with the search strategy. (Search strategy is provided in Supplementary Appendix 5). Study Selection All research, including randomized controlled trials (RCTs), quasi-experimental studies, and observational studies that included data on physical health parameters of CPR health care workers, was included. The primary outcome of interest was high-quality CPR as defined in the respective studies (Table 1). We deliberately did not prespecify a single fixed operational definition (such as chest compression fraction >80% or compression rate >100/min) because doing so would have severely restricted study inclusion and excluded a substantial body of relevant evidence. CPR quality has been operationalized differently across studies, reflecting evolving international guidelines, variations in study objectives, and differences in simulation protocols. For example, some studies defined CPR quality solely by compression depth, others by compression rate, percent of correct compressions over varying time periods, fatigue-related decay, or composite scores, rather than by CCF alone.1,4, 5, 6 Limiting inclusion to a single metric would therefore have selected only a narrow subset of studies and introduced selection bias toward specific outcome constructs. Instead, we adopted a conceptual definition of high-quality CPR, whereby any objectively measured CPR performance parameter defined by the primary investigators in accordance with the prevailing CPR guidelines at the time of the study was eligible for inclusion. This approach allowed the incorporation of studies that assessed CPR quality using guideline-concordant metrics appropriate to their study period, though the outcome is conceptually similar but operationally heterogeneous. Table 1Nonhomogenous CPR quality outcomes and variables measured.S. No.AuthoryearcountryCPR quality outcome measured(including time duration)1Lin et al12015Taiwan2-min hands-only CPR trial on manikinHigh-quality CPR is defined asCompression rate ≥100/minAverage compression depth ≥5 cm2López-González et al162016Spain20 min of external chest compression on a manikinCPR quality assessed using ECC parametersCompression rate 100 to 120/min100% of compressions with a depth ranging between 50 and 60 mm3Lancaster et al172021United States of America (USA)40 min prolonged CPR protocol with alternating roles every 2 min (10 cycles of 2-min compressions with breaks)CPR quality is defined by compression rate >100/min, depth >2 inches (50 mm), and adequate/full recoilCPR Quality Score = rate × depth4Schoen et al182017United States of America (USA)4 min of continuous chest compression (phase 1)20 min of continuous chest compression with sequential compressor rotation every 2 min (phase 2)CPR quality was assessed by compression rate at least 100 compressions per minute, compression depth at least 2 inches, and adequate recoil, % correct compressions reported across compressor rotations/teams5Cobo-Vázquez et al19Spain15 min of continuous chest compressions on a manikinCPR qualityEffective compressions (≥80% correct)Compression rate ≥100/min andCompression depth ≥50 mmMuscle fatigue and compression effectiveness were assessed at 2, 5, and 15 min6Ock et al6Korea5 min uninterrupted chest compressionCPR quality is defined as the percentage of correct compressions. Compression rate 100/minCorrect compression depth 4-5 cmOutcomes were analyzed in 5 consecutive 1-min segments, showing time-dependent decay in CPR quality7Abelairas-Gómez et al20Spain10 min of prolonged CPR on a manikin.CPR quality is defined usingCompression rate 100-120/minMean compression depth 5060 mmRescue breadth 500-600 mL of volumeQuality was analyzed minute-by-minute, with emphasis on maintenance of depth and correct compression fraction over time8Nayak et al72020IndiaContinuous chest compression until perceived maximal fatigue mean duration was 193 sCPR quality operationalized byCompression rate 100/minCompression depth ≥5 cmThe primary CPR outcome was duration of sustained effective compressions, rather than depth or rate, averaged over a fixed-time window9Hansen et al52011Belgium15-min continuous cardio-cerebral resuscitation (CCR)CPR quality is defined asCompression rate ≥100/minAdequate compression depth (38-51 mm) within predefined timeframes (<1 min, 1-3 min, 3-5 min, 5-10 min, 10-15 min).CPR quality expressed as % adequate depth, not a binary HQCPR outcome10Hasegawa et al4Japan5-min uninterrupted chest compressions on manikinCPR quality is defined asPercentage of adequate compressions ≥5 cm depth, assessed every 30 sCompression rate fixed at 100/minOutcome focused on depth adequacy over time, not combined rate and depth criteria11Więch et al8Poland2-min single-rescuer CPR (30:2) on manikin.CPR quality assessed using multiple parameters:Adequate chest compression rate 100-120/minAdequate chest compression depth 5-6 cmAdequate chest recoilTidal volume 6-7 mL/kg12Krikscionaitiene et al21Lithuania6-min BLS test immediately posttrainingCPR quality is defined byMean compression depth per minute, dichotomized as sufficient (≥50 mm) vs insufficient (<50 mm)Compression rate is not included in the high-quality CPR definition, outcome is focused exclusively on depth adequacy over time13Russo et al22GermanyTwo 9-min sequences of external chest compressions (ECC) using 15:2 and 30:2 compression–ventilation ratios.CPR quality was defined by a mean compression depth of 4-5cm, a compression rate of 100 per min, and fatigue-related decay in depth over time. Depth and rate were analysed minute-by-minute across the 9-min duration14Peberdy et al23United States of America (USA)2 min of uninterrupted chest compressions on a manikin.CPR quality was defined byCompression rate 90-110/min andCompression depth 1.5-2 inches.Outcomes were reported as a percentage of compressions within the guideline range during the 2-min test15Arrogante et al242021SpainCPR performance was assessed during 2-min CPR compression–ventilation cycles, repeated pretraining, immediately posttraining, and at 3-mo follow-up.CPR quality was defined byCompression depth 5-6 cmCompression rate 100-120/min, recoil, and hand position16Jaafar et al25Kuwait5 cycles of CPR (30:2) following training.CPR quality was defined asEffective chest compressions when ≥80% of compressions met depth criteria ≥2.5 inchesEffective chest compression rate when ≥100/min, calculated over the entire 5-cycle CPR sequence.Ventilation quality was assessed separately based on adequate chest rise in ≥80% of ventilations17Rad et al26IranCPR on a manikin until self-reported onset of physical fatigue (most fatigued by 2 min).CPR quality assessedCompression depth ≥5 cmNumber of compressions >200Absence of prolonged interruptions (<10 s)Outcome focused on the ability to sustain adequate depth and compression count until fatigue, rather than a fixed-time high-quality CPR definition18Oh et al27KoreaFive cycles of CPR (30:2)CPR quality is defined solely by average chest compression depth.Adequate CPR is inferred from achieving a mean depth ≥50 mm. Compression rate and time-based decay were not part of the primary outcome19Sayee et al28IrelandTwo 3-min CPR sessions (15:2 and 30:2), separated by rest. CPR quality is defined as >80% of compressions achieving depth ≥38 mm over each 3-min period.Outcome dichotomised as effective vs ineffective CPR based on depth criterion only20Kim et al29KoreaFour cycles of chest compressions for 1 min, followed by a 1-min rest, or 2 cycles of chest compressions for 2 min, followed by a 2-min rest, with compression rate fixed at 120/min.Two-rescuer simulated CPR with alternating compression cycles, comparing 1-min shift cycles vs 2-min shift cycles.CPR quality was defined using a mean compression depth of 50-60 mm and a compression rate of 120 times per minuteA 0- to 100-point visual analog scale (VAS) was used to record subjective fatigue21Ashton et al30United KingdomTwo consecutive 3-min periods of uninterrupted chest compressions, separated by 30 s.CPR quality is defined asNo. of satisfactory compressions: depth 4-5 cm/min. Compression rate 100/minQuality outcome focused on minute-by-minute decline in satisfactory compressions due to fatigue22Kessler et al31United States of America(USA)2-min continuous chest compressionHigh-quality CPR defined asCompressions depth 50-60 mmCompression rate 100-120/minMinimal lean (≤5 mm)Outcomes reported as percentage of compliant compressions and analyzed in 4 30-s epochs to assess fatigueBLS, basic life support; CCR, cardio-cerebral resuscitation; CPR, cardiopulmonary resuscitation; CVR, compression–ventilation ratio (eg, 30:2 or 15:2); ECC, external chest compression; HQCPR, high-quality cardiopulmonary resuscitation; MCD, mean compression depth; VAS, visual analog scale. Nonhomogenous CPR quality outcomes and variables measured. BLS, basic life support; CCR, cardio-cerebral resuscitation; CPR, cardiopulmonary resuscitation; CVR, compression–ventilation ratio (eg, 30:2 or 15:2); ECC, external chest compression; HQCPR, high-quality cardiopulmonary resuscitation; MCD, mean compression depth; VAS, visual analog scale. Reviews, case reports, case series, commentaries, protocols, letters to the editor, editorials, conference proceedings, pediatrics, animal data, and out-of-hospital cardiac arrest involving bystander CPR were excluded from this SR. Studies published in languages other than English were excluded. In addition, studies mentioning physical health and fitness parameters without any association with the outcome of interest, that is, high-quality CPR, were also excluded. Data Extraction and Synthesis All identified studies from the 3 databases were transferred to a validated web screening tool, rayyan.ai, for screening.12 All studies published up to February 22, 2025, were included in the review. After deleting the duplicates, the titles and abstracts of retrieved articles were independently screened by 2 reviewers (PP and SC). The full texts of the included articles were retrieved and independently evaluated for eligibility by 2 reviewers. A third reviewer (VK) resolved any discrepancy between the 2 reviewers through discussion. Data Extraction and Synthesis The data extraction included the author’s name, year of publication, study design, sample size, physical health parameters included in the study, and the specific parameter to determine high-quality CPR based on the prevailing guidelines (as the outcome parameter in the respective studies). The measures of significance and strength of association between specific parameters and high-quality CPR were extracted by 2 reviewers, PP and SC. The third reviewer, VK, was also involved in data extraction to reduce any bias. All the data were tabulated systematically, and the methodology of each study was presented concisely in the tables. The main conclusions from each study were documented (Table 2). Due to differences in data presentation, a complete meta-analysis could not be carried out as planned. Table 2Characteristics of the included studies.Sl.No.Author nameYearCountryStudy designPurpose of the studyBaseline health parameters included in the studySignificant health/fitness parameterSample size (N)Guidelines followed in respective studies andConclusion1.Lin et al12015 TaiwanPost hoc analysis of the surveyTo identify factors associated with the performance of high-quality CPR by health care workers using a manikin-based methodAge (years)GenderBody weight, (kg)Body height, (cm)BMI, (kg/m2)Arm length, (cm)Leg length, (cm)Thigh length, (cm)Average exercise frequency, per week (session/week)Average exercise duration, (min)BMI × higher physical exercise time per week(combined index)Higher exercise frequency per weekHigher exercise durationHigher total exercise time per weekN = 952010 American Heart Association guidelinesEuropeanResuscitation Council Guidelines for Resuscitation 2010 sectionTo optimize CPR quality, a program of exercise frequency and duration adjusted according to an individual's BMI should be considered in such populations.2.López-González et al162016SpainCross-sectional analyticalThe objectives of this study were 2-fold:(1) to analyze, in college students, the relationship between BMI andmuscle strength with adequate external chest compression (ECC) parameters(2) to examine whether the association between BMI and adequate ECC parameters is mediated by muscle strengthAge (years)Weight (kg)Height (m)Body mass index (kg/m2)Weight status (%)UnderweightNormal weightOverweight/obesityHandgrip/weight Cardiorespiratory fitness (VO2max; mL kg−1 min−1)Higher BMIHigher strength of the upper body (higher hand grip/weight ratio)N = 63American Heart Association 2015European Resuscitation Council Guidelines for Resuscitation 2015The ability to provide adequate ECC is influenced by the muscular strength of rescuers.Exercises focused on improving upper-body muscle strength might improve the ability to perform correct resuscitation maneuvers.3.Lancaster et al172020United States of AmericaExperimental studyTo assess the time course of declines in quality CPR during a realistic protocol of 40-min duration, and when switching resuscitation rolesevery 2 min(2) To determine the measures of functional fitness that are associated with betterCPR performance over this duration.Age (years)Weight (kg)Height (cm)Body mass index (kg/m2)Bench press (repetitions)Crunches (repetitions)Sorensen test (s)Anaerobic power (kJ)Ratings of Perceived Exertion (RPE)Upper body and Lower back RPEHeart rate (bpm)Systolic blood pressure (mm Hg)Diastolic blood pressure (mm Hg)Higher heightHigher weightHigher BMIHigher upper-body muscular strengthHigher anaerobic power and high bench press scoresN = 54American Heart Association 2020Most rescuers can maintain high-quality CPR with 2-min breaks between cycles.Rescuers with highanaerobic fitness and muscular strength may enable higher-quality CPR.4.Schoen et al182017United States of AmericaExperimentalTo study the impact of the size of resuscitation teams, specifically the number of alternating health care workers delivering chest compressions(phase 1)Targeted rest-recovery exercises on chest compression quality and individual provider exertion during a simulated cardiac arrest.(Phase II)Age (years)GenderWeight (kg)BMI (kg/m2)Maximal Predicted Heart Rate (bpm)Lesser % of the maximum predicted heart rate with stretch and diaphragmatic breathing exercises between compressionsLesser energy expenditure per compression with stretch and diaphragmatic breathing exercises between compressionsHigher weightHigher BMIFor phase 1Sample size 45For phase IIN = 30(Including 2 compressors, 3 compressors, and 4 compressors team)For phase II with only 2 compressor team, N = 26American Heart Association 2015 guidelinesMembers of 2-compressor teams exhibited higher levels of exertion than members of larger compressor teamsfor comparable simulated chest compression performance.Stretching and breathing exercises intended to assist with compression recovery exhibited mixed effects on compressionperformance and subject exertion5.Cobo-Vázquez et al192017SpainCross-sectionalTo evaluate by electromyography the onset of muscle fatigue after continuous chest compression, following the AHA guidelines and the European Council guidelinesThe secondary objective was to determine the maximum time a rescuer can maintain effective chest compression without interruptionsAge (years)Height (cm)Weight (kg)BMI (kg/m2)Hand dominanceHigher muscular force (electromyography) in the high spinal muscle group and the lumbar muscle group (L5)N = 11AmericanHeart Association 2015The European Resuscitation Council 2015The International Liaison Committee on Resuscitation2015Fatigue of the spinal and lumbar musculature involved in CPR occurred after 2 minof activity.Time was the only influential factor.6.Ock et al62011KoreaExperimental(The author has written an experimental setting.)To evaluate the influence of the physical fitness of the CPR provider on the quality of chest compression, and the physiological changes during continuous chest compressions for 5 min.To investigate the effects of the rescuer’s sex, weight, and height on the quality of the delivered CPRAge (years)Height (cm)Weight (kg)BMI (kg/m2)Peak oxygen consumption(VO2max,ml/kg/min) testEndurance (%)—handgrip test that measures gripping power (kg)for 10 sMuscle strength (kg)—handgrip strength of right and left handMuscle power (watts)Reactive agility (ms)Systolic BP (mm Hg)Diastolic BP (mm Hg)Higher muscle strength (higher hand grip strength) is indicative of upper-body muscle strengthN = 47American Heart Association 2005 guidelinesAbility to provide a satisfactory chestCompressions deteriorated significantly after a brief time period, which may be affected by the rescuer’s physical fitness.A fitness program, such as muscle-strength exercise for CPR health care workers, should be considered for improving survival from cardiac arrest.7.Abelairas-Gómez et al202016SpainQuasi-experimentalTo investigate the effects of a strength training program on the quality of prolonged basic cardiopulmonary resuscitation on a manikinAnthropometric data:Height (units of measurement not reported)Weight (units of measurement not reported)Body mass index (kg/m2)Fat factor (%)Total lean mass Right and left upper-limb muscle massTrunk muscle massHigher lean mass and higher upper-limb (R &L) muscle massLower mean body fat percentageN = 50 (screened)N = 39 participants analyzedExperimental group, N = 23Control group, N = 16EuropeanResuscitation Council Guidelines for Resuscitation 2015A simple strength training program has a significant impact on the quality of chest compressions and their maintenance over time.Additional training is needed to avoid over-ventilation of potential patients.8.Nayak et al72020IndiaProspectiveCross-sectionalTo study physical activity (PA) levels of the CPR-trained health care workers (HCW) and their effect on chest compression duration and hemodynamic parameters of the rescuers, and their fatigue level during the simulated chestcompression-only CPRAge (years)GenderBMI (kg/m2)Physical activity level through GPAQHigher physical activity among CPR HCWN = 48American Heart Association 2015 guidelinesThe health care workers fitness level is an important factor in determining chest compression durationThe higher the PA, the lower the fatigue level and the longer the duration of chest compression9.Hansen et al52011BelgiumDefinitive quasi-experimentalTo evaluate the impact of cardiopulmonary exercise capacity and muscle strength on the performance of 15 min of sustained, continuous external chest compressions using only CCR among healthy health-care professionalsAge (years)Height (cm)Weight (kg)BMI (kg/m2)VO2peak (ml/min)Ventilatory threshold (ml/min)Isometric elbow extension peak torque at 90° Newton-meter(Nm) Isokinetic elbow extension work fatigue at 270°/s (%)Maximal hand grip strength (kg)Higher heightVentilatory threshold (ml/min)Higher upper-limb muscle strengthN = 15International Liaison Committee on Resuscitation 2005 guidelinesThe ventilatory threshold was the only predictor of good CCR quality up to 5 min, but not beyond this timeframe.The ventilator threshold is an estimation of the anaerobic threshold and indicates the oxygen uptake level above which aerobic energy production is supplemented by anaerobic mechanisms. After 5 min of sustained CCR, the quality of chest compressions is related to maximal muscle strength.10.Hasegawa et al42014JapanExperimentalTo clarify associations between the quality of chest compression and body weight as well as the physical fatigue of rescuersAge (years)Height (cm)Weight (kg)BMI (kg/m2)Exercise habitHeart rate (bpm) and oxygen uptake VO2 (mL/kg/min) during CPRHigher weightHigher BMILower heart rate during CPRLower integrated electromyography signals of muscle activity (indicating lesser muscle fatigue) in erector spinae, external oblique, abdominal rectus, and rectus femorisN = 18American Heart Association 2010 guidelinesChest compression caused increased fatigue among the light group, which consequently led to a gradual decline in the quality of chest compression.Individuals with a lower body weight should rotate at 1-min intervals to maintain high-quality CPR and thus improve the survival rates and neurologic outcomes of victims of cardiac arrest.11.Więch et al82021PolandObservational cross-sectionalTo assess the relationship between selected body composition components and chest compression and ventilation parameters provided by medical staffWeight (kg)Height (cm)BMI (kg/m2)BMR (kcal)Body cell mass index (kg/m2)Physical activityBody composition parametersFat mass (%)Fat-free mass (%)Body cell mass (%)Muscle mass (%)Higher weightHigher heightHigher BMIHigher body cell mass indexHigher fat massHigher fat mass (%)Higher fat-free massAmong the fat-free mass componentsHigher body cell massHigher muscle massHigher total body waterN = 505European Resuscitation Council Guidelines for Resuscitation 2021Nutritional status and body composition components may be significant factors affecting the quality of CPR.High values of anthropometric(weight, height), nutritional (BMI, PA, BCMI) and body composition (FM, FFM, BCM, MM,TBW) parameters of medical staff predicted better compression results.The relationship was inversely related to an adequate chest recoil for all the parameters listed.12.Krikscionaitiene et al212012LithuaniaCross-sectionalTo evaluate associations between rescuers’ anthropometric characteristics (weight, height, BMI, and body fat percentage) and CCs depthWeight (kg)Height (cm)BMI (kg/m2)Fat% (%)Higher weightHigher heightHigher BMIN = 186American Heart Association 2010 guidelinesLightweight rescuers may have difficulty achieving the full compression depth of 5-6 cm.These rescuers require special attention during CPR training, with an emphasis on correct body positioning and use of body weight.13.Russo et al222011GermanyRandomized, crossover trialTo investigate the impact of rescuers’ physical fitness, biometry, and gender on the quality of ECC using CVRs of 15:2 and 30:2Age (years) Body weight (kg)BMI (kg/m2)Personal watt capacity; PWC170 (watts)Heart rate at 75 Watts of rowing (bpm)The physical fitness was assessed by cycling and rowing ergometry (focusing on lower and upper body, respectively).Male genderLower heart rate at 75 watts of rowing ergometryHigher BMIBetter physical fitnessN = 40American Heart Association 2010 guidelinesEuropeanresuscitation council guidelines for resuscitation 2010Good physical fitness and a higher BMI (in this study above 25.4kg/m2) correlate positively and independently of gender with the quality of ECC2. Female participants performed ECC that was too shallow and more rapid compared to male participants.3. Compression depth decreased over time among less fit participants and participants with a lower BMI.4) A compression–ventilation ratio (CVR) of 30:2 was rated to be not only more exhausting but also more comfortable.5) Physical fitness tests focusing on the upper body of the health care provider may be a reliable predictor of ECC quality.14.Peberdy et al232009United States of AmericaExperimentalTo characterize the quality of CC performed by hospital personnel, evaluate for predictors of CC performance, and determine the effects of audiovisual feedback on CC performanceTo identify individual provider characteristics that could serve as predictors of chest compression qualityAge (years)GenderCPR trainingMale genderYounger age(21-30 years)Experiment 1N = 754American Heart Association 2005 guidelinesThe quality of chest compression can be improved with the use of CPR feedback technologies.15.Arrogante et al242021SpainRandomizedcontrolled trialTo analyze the effects of a structured training course based on deliberatepractice using an FD and the physical characteristics of an individual nursing student on ventilation, chest compressions, and the overall quality of CPR performance before, just after, and 3 months after such training.Age (years)GenderWeight (kg)Height (cm)Handgrip strength (kg)CPR position strength (kg)FEV1/FVC (%)None of the parameters correlated to high-quality CPR (height, weight, handgrip strength, FEV1/FVC, CPR position strength)Total, N = 60Control group, N = 28Training group, N = 32American Heart Association 2020 guidelinesEuropeanresuscitation council guidelines for resuscitation 2021The rescuer’s physical characteristics do not affect CPR performance while they perform 2-min CPR compression/ventilation cycles16.Jaafar et al252015KuwaitCross-sectionalTo test the association between rescuers’ gender, body mass index (BMI), and the accuracy of CCs, as well as ventilationAge (years)GenderWeight (kg) Height (cm)BMI (kg/m2)Lower BMI (<26kg/m2)Female genderN = 72American Heart Association 2010 GuidelinesCPR can be influenced by factors, such as gender and BMI; as such, the individual rescuer and CPR training programs should take these into account to maximize the victims’ outcomes.17.Rad et al262017IranCross-sectionalTo assess the factors relevant to the onset time of physical fatigue and resuscitation quality during cardiopulmonary resuscitation (CPR) provision by Iranian nursesAge (years)GenderWeight (kg)Height (cm)Male genderHigher weightHigher heightN = 194American Heart Association 2010 GuidelinesMale nurses with greater height and weight should be assigned to rescue teams in ICU wards.Mandatory for the nurses currently working in such teams in hospitals to improve their physical fitness through doing aerobics on a regular basis, so that they may experience less fatigue during their CPR operations in the future18.Oh et al272016KoreaRetrospective cross-sectionalTo determine if rescuer body weight is a major determinant of CCD among novice rescuers by analyzing the results of cardiopulmonary resuscitation (CPR) skill testsAge (years)Weight (kg)Height (cm)BMI (kg/m2)Higher body weightHigher heightHigher BMIN = 107American Heart Association 2015 GuidelinesRescuer body weight is a major determinant of CCD in novice rescuers. Based on these findings, if 2 or more rescuers are available to perform CPR, chest compression should be performed preferentially by rescuers of a healthy weight or overweight.19.Sayee et al282011IrelandRandomized crossover experimentalTo subjectively and objectivelyassess the CPR performance of FY1 doctors and to identify factors that may influence the quality of this basic life supportAge (years)BMI (kg/m2)Male genderHigher BMI (>24 kg/m2)N = 34EuropeanResuscitation Council Guidelines for Resuscitation 2005CPR performance can be influenced by factors, such as gender and BMI.Males and those females with a BMI of >24 performed satisfactory CPR.Females with a BMI <24 performed CPR more effectively when using the 15:2 ratio. FY1 doctors should be fully assessed prior to performing CPR at in-hospital cardiac arrests.20.Kim et al29 2017KoreaRandomized crossoverThe authors evaluated that changing the shift cycle from 2 min to 1would have a positive effect on the quality of chest compression in a 2-rescuercardiopulmonary resuscitation (CPR), regardless of rescuer strength.Age (years)Height (m)Weight(kg)BMI (kg/m2)Muscle strength (kg)Higher handgrip muscle strengthN = 39American Heart Association 2015 GuidelinesEuropeanResuscitation Council Guidelines for Resuscitation 2015Quality of chest compressions could be improved by changing the shift cycle from 2 min21.Ashton et al302002United KingdomQuasi-experimentalThe aim of the study was to determine if rescuer fatigue occurs during 3 min of chest compressions and, if so, its effects on the rate and quality of compressions.Age (years)GenderWeight (kg)Height (cm)Male genderHigher heightHigher weightN = 40American Heart Association 2000 Guidelines with ILCOREuropeanResuscitation Council Guidelines for Resuscitation 2001, sectionThe rescuer fatigue adversely affects the quality of chest compressions when performed without interruption over a 3-min period, and this effect may be greater in females due to their smaller stature. Consider rotating the rescuer performing chest compressions every 1 min.22.Kessler et al312020United States of America(USA)Secondary cross-sectionalThe study aimed to characterize the impact of provider anthropometric characteristics on the provider fatigue and overall, 2-min chest compression performance while receiving standardized visual feedback on qualityGenderHeight (cm)Weight (kg)BMI (kg/m2)Medium BMI category (22.2-26.3kg/m2)N = 377American Heart Association 2015 guidelinesThe 2-min interval for changing chest compressors should be reconsidered based on individual provider characteristics and the risk and impact of fatigue on high-quality CPR.AHA, American Heart Association; BCM, body cell mass; BCMI, body cell mass index; BMI, body mass index; CC, chest compression; CCD, chest compression depth; CCR, cardio-cerebral resuscitation; CPR, cardiopulmonary resuscitation; CVR, compression-to-ventilation ratio; ECC, external chest compression; ERC, European Resuscitation Council: FD, feedback device; FEV1, forced expiratory volume in one second; FM, fat mass; FFM, fat-free mass; FVC, forced vital capacity; GPAQ, Global Physical Activity Questionnaire; HCW, health care workers; ICU, intensive care unit; ILCOR, International Liaison Committee on Resuscitation; MM, muscle mass; PA, physical activity; PWC, physical working capacity; RPE, rating of perceived exertion; TBW, total body water. Characteristics of the included studies. AHA, American Heart Association; BCM, body cell mass; BCMI, body cell mass index; BMI, body mass index; CC, chest compression; CCD, chest compression depth; CCR, cardio-cerebral resuscitation; CPR, cardiopulmonary resuscitation; CVR, compression-to-ventilation ratio; ECC, external chest compression; ERC, European Resuscitation Council: FD, feedback device; FEV1, forced expiratory volume in one second; FM, fat mass; FFM, fat-free mass; FVC, forced vital capacity; GPAQ, Global Physical Activity Questionnaire; HCW, health care workers; ICU, intensive care unit; ILCOR, International Liaison Committee on Resuscitation; MM, muscle mass; PA, physical activity; PWC, physical working capacity; RPE, rating of perceived exertion; TBW, total body water. Data Analysis Our original plan, as registered in PROSPERO (CRD42024578517), was to conduct a meta-analysis. However, after examining the included studies, we found that it was not feasible due to substantial differences across studies in outcome definitions (composite CPR quality scores vs individual compression parameters), CPR assessment time frames (single 2 minute (min) sessions vs prolonged protocols of up to 40 min), statistical reporting approaches (regression coefficients and correlation analyses), and the absence of comparable effect estimates with associated variance measures (eg, odds ratios, mean differences, or standardized mean differences) (Table 1). As quantitative pooling of data was not feasible, subgroup analysis, meta-regression, and application of fixed- or random-effects models were not applicable. The risk of bias was assessed using the Joanna Briggs Institute (JBI) critical appraisal tool for observational,13 quasi-experimental,14 and RCTs15 (Supplementary Appendices 1-4). Results Study Selection A total of 11,895 articles were retrieved from all 3 databases (PubMed 3188, Scopus 8414, and Cochrane 293), of which 1610 duplicates were removed, leaving 10,285 for title and abstract screening. After that, 104 articles were eligible for full-text screening. A total of 82 studies were excluded. The various reasons for their exclusion are the absence of CPR health care workers physical health parameters (n = 33), non-specific CPR quality assessment (n = 17), wrong study design (n = 13), wrong population (n = 10), wrong publication type (n = 7), and non-English language (n = 2). Finally, 22 studies were included in this SR.1,4, 5, 6, 7, 8,16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31 The reasons for exclusion and the selection process are depicted in the PRISMA flow chart (Figure 1). PRISMA flow diagram of the search and screening process. PRISMA, Preferred Reporting Items for Systematic Reviews and Meta-Analyses. Characteristics of Included Studies A total of 22 studies were published between 2002 and 2024, including 2492 participants who performed CPR on manikins.1,4, 5, 6, 7, 8,16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31 There were 6 nonrandomized experimental studies, 4 RCTs, 7 cross-sectional observational studies, and 1 was a post hoc analysis of a survey. Four studies have not explicitly mentioned the study design.5,19,21,30 The characteristics of the included studies are mentioned in Table 2. The high-quality CPR criteria evaluated among CPR health care workers varied across studies (Table 1). The CPR quality guidelines that were followed in the studies were 2000,30 2005,6,23 2010,1,4,18,21,22,25,26 2015,7,19,27,29,31 and 202017,24American Heart Association guidelines (Table 2). The 2001,30 2005,28 2015,9,20,29 and 202124 European Resuscitation Council guidelines, as well as the 20055 and 201519 International Liaison Committee guidelines, were followed in the studies (Table 2). The included studies were based on physical health parameters of CPR health care workers and their association with high-quality CPR outcomes. Physical Health Parameters Included in the Studies The Physical health parameters of CPR health care workers were classified and assessed in the included studies (Table 2). They were demographic variables: age, gender, height, body composition (FM, MM, and TBW), body cell mass (BCM), weight, and body mass index (BMI); exercise behavior: exercise frequency and duration per week; muscle strength: handgrip strength, anaerobic power, upper-limb strength and endurance; muscle activity: electromyography (EMG) studies; fitness: maximal oxygen uptake (VO2 max) as a percentage of predicted value (% pred) and maximum heart rate (HR max); respiratory function: forced expiratory volume in 1 second (FEV1) and forced vital capacity (FVC); and cardiovascular function: systolic blood pressure (BP). A summary of health parameters across the included studies is depicted in Table 3, and the physical health predictors of high-quality CPR are shown in Supplementary Table S1. Table 3Summary of health parameters assessed across included studies.Author/yearAgeHtWtBMIPhysical exercise frequency or duration per weekHand grip strength/upper-body muscle strengthAnaerobic power/bench press scoreUpper-limb muscle strength or endurance% maximum predicted HRMuscle fatigue—spinal, lumbar, or abdominal muscles (EMG)Body composition fat/muscle/water/cellFEV1/FVCVentilation thresholdPeak oxygen uptake capacityLin et al1/2015✓✓López-González et al16/2016✓✓✓Lancaster et al17/2021✓✓✓✓✓Schoen et al18/2017✓Cobo-Vázquez et al19/2017✓Ock et al6/2011✓Abelairas-Gómez et al20/2016✓Nayak et al7/2024✓Hansen et al5/2011✓✓✓Hasegawa et al4/2014✓✓✓✓Więch et al8/2021✓✓✓✓Krikscionaitiene et al21/2012✓✓✓Russo et al22/2011✓✓Peberdy et al23/2009✓Arrgante et al24/2021×××Jaafar A et al25/2015✓Rad et al26/2017✓✓Oh et al27/2016✓✓✓Sayee et al28/2011✓Kim et al29/2017✓Ashton et al30/2002✓✓Kessler et al31/2020✓%MPHR, percentage of maximum predicted heart rate; BMI, body mass index; FEV1, forced expiratory volume in 1 second; FEV1/FVC, ratio of forced expiratory volume in 1 second to forced vital capacity; FVC, forced vital capacity; HR, heart rate; EMG, electromyography; Ht, height; Wt, weight. Summary of health parameters assessed across included studies. %MPHR, percentage of maximum predicted heart rate; BMI, body mass index; FEV1, forced expiratory volume in 1 second; FEV1/FVC, ratio of forced expiratory volume in 1 second to forced vital capacity; FVC, forced vital capacity; HR, heart rate; EMG, electromyography; Ht, height; Wt, weight. Results Body mass index: 11 studies demonstrated a significant association between BMI and high-quality CPR.1,4,8,16,17,21,22,25,27,28,31 Most studies reported that participants with higher BMI (≥24-25 kilogram/meter2 [kg/m2]) achieved greater chest compression depth, rate, and overall CPR quality.4,8,16,17,21,22,27,28 Lin et al1 found that a combined index of BMI and weekly physical exercise was a significant predictor of CPR quality, with an area under the receiver operating characteristic curve (AUC) of 0.718, 95% CI of 0.613 to 0.824; sensitivity of 72.2%, and specificity of 67.8%. Hasegawa et al4 and Więch et al8 reported positive correlations between BMI and adequate compression depth, although Więch et al noted an inverse relationship with chest recoil. Hasegawa et al stratified participants into 2 groups, light and heavy, based on weight and BMI. The light group had significantly lower mean BMI than the heavy group (18.2 ± 1.6 vs 24.4 ± 2.8 kg/m2). The median proportion of adequate chest compressions in the light group declined progressively from 77% to 0%, whereas in the heavy group, it declined from 98.1% to 77.3%. The decline in adequate chest compressions over time was statistically significant within the light group from 150 seconds (s) to 300 s (P = .028), and between-group differences were significant at multiple time points from 90 to 300 s (P ranged from 0.049 to 0.022). So, these results support that lower BMI was associated with earlier fatigue and reduced the ability to sustain adequate compression depths.4 Krikscionaitiene et al21 found a significant association between BMI and compression depth in female health care workers, odds ratio (OR), 2.37; 95% CI, 1.01 to 5.75. Conversely, Jaafar et al25 observed better depth performance in participants with BMI <26 kg/m2 compared with those with BMI ≥26 kg/m2 (82% vs 57% chest compressions, P = .04), indicating superior depth performance in the lower BMI group. Kessler et al31 found a nonlinear relationship with BMI and CPR quality. Using the lowest BMI as a reference, participants in the middle tertile of BMI category had higher odds of delivering high-quality CPR (OR, 2.53; 95% CI, 1.5-4.4; P < .05) as compared to participants in highest BMI tertile did not show statistically significant improvement in overall CPR quality with the reference group (OR, 1.41; 95% CI, 0.80-2.40; P = .21). Hence authors concluded that those in the middle tertile of BMI (22.2-26.3 kg/m2) performed best, supporting an inverted U relationship between BMI and CPR.31 Body weight: 9 studies identified body weight as a significant physical factor influencing high-quality CPR performance.4,8,16,17,21,24,26,27,30 Higher body weight was consistently associated with improved chest compression depth, rate, and fatigue resistance. Hasegawa et al showed that health care workers in the heavy group (median weight 68.0 kg) achieved significantly greater compression depth than those in the light group (median weight 50.6 kg).4 The median percentage of adequate compressions for each 30-s interval by the heavy and light group of CPR health care workers ranged from 98.1% to 77.3% and 77.4% to 0%, respectively (P < .05).4 Underweight participants (BMI <18.5 kg/m2) had poorer compression depth as compared to normal weight participants (BMI 18.5-24.9 kg/m2) and overweight participants (≥25 kg/m2) in the study by López-González et al.16 The percentage of correct compression depth in the respective categories were 36.4% ± 30.6%, 70.7% ± 28.3% and 87.7% ± 11.4 % in the study (P < .018).16 Several studies reported moderate to strong correlations between body weight and compression quality metrics, including Lancaster et al17 (Pearson correlation r = 0.42), Więch et al (Spearman correlation r = 0.40 for depth; Spearman correlation r = –0.25 for recoil), and Oh et al27 (Pearson correlation r = 0.636), with effective depth achieved at >70.5 kg. Ashton et al30 also found consistent correlations between weight and compression quality over consecutive time intervals (first 3-min period: Spearman correlation r = 0.51; second 3-min period: Spearman correlation r = 0.48; both statistically significant, P < .01). However, Arrogante et al24 found no significant association between body weight and CPR performance. Height: 8 studies reported height as a significant factor influencing CPR quality.5,8,17,21,24,26,27,30 Taller health care workers were associated with better compression depth, rate, and endurance. Positive correlations between height and CPR performance metrics were observed across multiple studies (Spearman correlation or Pearson correlation r range, 0.18-0.544; P < .05).5,8,27,30 In another study by Rad et al,26 7.4% of subjects who were <170 centimeters (cm) tall delivered more than 200 compressions before becoming fatigued after 2 min, whereas 31.3% of subjects >170 cm height delivered >200 compressions during their CPR (P = .001). Another study identified inadequate compression depth in shorter female health care workers (OR, 3.73; 95% CI, 1.53-9.09) as compared to taller participants.21 Age: Peberdy et al23 found that the mean depth of chest compression was lower in participants aged 51 to 60 years (1.54 ± 0.29 inches) as compared to those aged 21 to 30 years (1.66 ± 0.31 inches, P = .02) or 31 to 40 years (1.65 ± 0.31 inches, P = .03). Handgrip/upper-body strength: 5 studies identified handgrip strength as a significant predictor of high-quality CPR.6,16,17,24,29 Stronger handgrip correlated with improved compression depth, rate, and overall performance. Ock et al6 reported strong positive correlations between handgrip strength and compression metrics, especially during the second to fifth min of CPR (Pearson correlation r = 0.108-0.39). In multivariable regression analysis, handgrip emerged as the only predictor of correct chest compressions (standardized β = 0.53; coefficient of determination R2 = 0.49).6 Kim et al29 showed that handgrip had a positive association with mean compression depth (Spearman correlation r up to 0.82; P < .01). López-González et al found that participants with higher grip strength achieved significantly better compression depth as compared to medium muscle strength and low muscle strength (87.6% ± 15.5% and 52.7% ± 32.4% vs 35.6% ± 27.2%, respectively, P < .001) and adequate compressions (85.3% ± 14.9% and 52.5% ± 31.1% vs 32.3% ± 24.7%, P < .001). Lancaster et al linked upper-body strength and anaerobic power with CPR quality (Pearson correlation r = 0.269-0.641; P < .05). Only Arrogante et al found no significant association. Heart rate during CPR: 3 studies reported an association between HR and CPR quality.4,17,22 Hasegawa et al found that heavier health care workers had significantly lower HR during compressions at each 30-s interval, ranging from a median HR of 118.2 to 97.2 beats per min in the heavy group to 134.3 to 109.9 beats per min in the light group (P < .05 at all 30s time intervals from 60 to 270 s). Schoen et al18 showed that health care workers performing stretching and breathing exercises during rest had a lower mean increase in % of maximum predicted HR (67% during the fifth rotation vs 75.4%, P = .01) compared to those sitting. Russo et al22 found a negative correlation between HR during rowing ergometry and compression quality (Pearson correlation r = −0.57, P < .05), with higher HR linked to reduced compression depth after 3 min. Physical exercise: 2 studies found that higher levels of physical activity were significantly associated with high-quality CPR.1,7 Lin et al reported that participants meeting CPR quality criteria had greater exercise frequency per week, with median 5 times, interquartile range (IQR) of [4-6] vs median 3 times IQR [1-5] P < .001), higher exercise duration (median 60 min IQR [42.50-60] vs median 40 min [30-60], P = .005), and higher average total weekly exercise time per week (median 300 min IQR [152.5-360] vs median 120 min IQR [30-300], P = .001), with total exercise time being an independent predictor (OR, 1.004; 95% CI, 1.000-1.008; P = .044). Nayak et al7 observed significantly longer chest compression duration in participants with high physical activity as compared to those with moderate physical activity (mean ± SD 217.22 ± 71.43 s vs 167.88 ± 39.76 s, P = .017). Body composition: 2 studies demonstrated that body composition significantly influenced CPR quality.8,20 Abelairas-Gómez et al20 found that strength training reduced body fat percentage (18.4%to 16.4%, P = .004), leading to a significant improvement in correct compression percentage (from 40.4% ± 31.6% to 68.2% ± 21.0%, P = .002). In the study by Więch et al, body composition was evaluated as 2 broad compartments consisting of FM and FFM. Furthermore, the FFM is compartmentalized into MM, TBW, and BCM. Adequate chest compression depth showed positive correlations with FM (Spearman correlation r = 0.34, P < .001) and MM (Spearman correlation r = 0.30, P < .001) and had the greatest correlation with TBW (Spearman correlation r = 0.36, P < .001).8 However, the TBW was also negatively correlated to adequate recoil (Spearman correlation r = −0.21, P < .001), BCM (Spearman correlation r = −0.23, P < .001), and MM (Spearman correlation r = −0.23, P < .001).8 Muscle force using EMG: 2 studies reported that muscle activity and fatigue impact CPR quality.4,19 Hasegawa et al found significantly higher EMG activity in multiple muscles (trapezius, erector spinae, obliques, rectus abdominis, and rectus femoris) among lighter CPR health care workers, indicating earlier fatigue compared to heavier individuals who maintained adequate compression >70% for 5 min. Cobo-Vázquez et al19 observed time-dependent bilateral fatigue in spinal and lumbar muscles after 2 min of CPR, leading to decreased compression quality. Upper-limb muscle strength, endurance, ventilation threshold, and anaerobic power: Hansen et al5 found significant positive correlation between external chest compressions and peak oxygen uptake capacity (Spearman correlation r = 0.54, P < .05), peak cycling power output (Spearman correlation r = 0.54, P < .05), maximum isometric elbow extension strength (Spearman correlation r = 0.55, P < .05), and ventilatory threshold (the exercise intensity at which lactic acid starts to accumulate in the circulation) (Spearman correlation r = 0.67, P < .05). Ventilatory threshold was the only predictor of good quality cardio-cerebral resuscitation (CCR) up to 5 min, whereas, after 5 min, isometric elbow extension strength correlated to the quality of CCR.5 Limitations Our review has several limitations. First, there were marked variations in how CPR quality was defined and measured across included studies. However, most studies assessed compression rate and depth; they differed significantly in assessment duration, threshold values, and statistical reporting. This variability rules out quantitative pooling and may lead to interpretive inconsistency across outcomes. Second, our inclusion strategy deliberately included studies using different guidelines concordant CPR quality definitions rather than restricting eligibility to a single operational metric. Being more inclusive also increased the conceptual heterogeneity in the collation of outcomes. Third, studies used BMI as a primary variable without differentiating between FM and MM because BMI does not accurately reflect body composition, potentially leading to misclassification of functional capacity. Though this issue was somewhat reduced by synthesizing studies that evaluated muscle strength and body composition, any results on BMI still need careful attention. Fourth, all included studies were conducted in manikin-based simulation settings, which may not fully capture the physiological stress and team dynamics of real-world IHCA. Discussion This review focused on the physical health parameters of CPR health care workers that have the potential to affect CPR quality. The health-care institutional CPR team should include health care workers with essential physical health parameters to ensure high-quality CPR delivery. Team-focused CPR is an important concept that focuses on high-functioning CPR teams to ensure optimal CPR performance.32 A recent concept of team-focused CPR with a specific “pit-crew” has been emphasized.32 Just like Formula One teams have team members who are adept at performing independent tasks efficiently with the same set of common goals, the CPR teams also require such synchronized dynamics.32 Such a CPR “pit-crew” may serve as a role model for other CPR health care workers, ensuring the best possible outcomes. Various health and fitness parameters have been associated with high-quality chest compressions, including BMI, body weight, height, and gender.1,4,5,7,8,16,17,21, 22, 23, 24, 25, 26, 27, 28,30,31 Though many of the studies have found that a higher BMI >24 kg/m2 was associated with better chest compression depth, a recent study by Kessler et al revealed that, in fact, it is those with a medium BMI (22.2-26.3 kg/m2) who were able to provide a high-quality CPR. The results demonstrated a nonlinear, inverted U relationship between BMI and CPR quality, with participants with either low or high BMI performing poorer chest compressions than those with medium BMI. However, BMI does not differentiate between MM and FM, providing limited insight into functional capacity for CPR. Studies evaluating body composition showed that higher lean mass, FFM, MM, BCM, and TBW were more consistently associated with adequate compression depth and resistance to fatigue.8 This showed that the observed association between BMI and CPR is likely to be mediated by underlying muscular strength and endurance.8,16,17,21,22,31 Jaafar et al reported findings contradictory to those of other studies, in which a BMI >26 kg/m2 was associated with a lower percentage of participants with correct depth and rate of chest compressions, which was attributed to 2 reasons. First was the fact that CPR health care workers who are overweight with a BMI >26 kg/m2 have a propensity for abnormal body positioning while the chest compressions are provided.25 The second reason is an expected early fatigability in such CPR health care workers is that in overweight individuals, there is an increased work of breathing and an increased oxygen expenditure during exercise due to a multiplicity of factors as compared to healthy individuals, there is an insufficient decrease in end-expiratory lung volume in overweight as compared to the healthy individuals thus leading to a diminution in the increase in tidal volumes during exercise, an increased work of breathing to expand both the lungs and the chest wall against the thoracic fat load leading to greater oxygen expenditure, and a reduction in pulmonary as well as chest wall compliance.33 The perception of dyspnea during exercise (walking uphill) is also greater (OR, 2.66) in overweight individuals compared with nonoverweight individuals, possibly due to increased afferent feedback through the “neural respiratory gate” at the subcortical level.33 All these factors could have contributed to the inability of overweight CPR health care workers (BMI ≥ 26 kg/m2) to ensure high-quality CPR in the study by Jaafar et al. The energy expenditure during CPR is 17.46 ± 4.77 kilocalories/min (kcal/min) at a 30:2 compression-to-ventilation ratio and 16.49 ± 4.35 kcal/min during chest compression only.1 As the energy expenditure during exercise is proportional to 3.37 times the body weight, obese individuals are likely to have more energy expenditure with each min of CPR.34A higher BMI could also have another drawback of lesser chest recoil.25 Thus, rather than BMI alone, a novel index (combined index) like the product of BMI and physical exercise time per week is a significant predictor of high-quality CPR.1 Several studies showed that handgrip strength and the frequency of time spent per week on physical exercise were associated with high-quality CPR.6,16,29 Muscle strength and endurance of the muscles active during CPR are important to ensure continuous, high-quality CPR. Apart from the upper-body muscles, the spinal and lumbar muscles are also active during chest compressions.35 The energy that is necessitated to provide high-quality chest compressions originates from the movement of the hip joint and is then transmitted to both upper extremities through the abdomen in the standing position.35 This probably explains the findings of the study by Cobo-Vázquez et al, where there was a time-dependent muscle fatigue in both high spinal and lumbar muscles after the peak of muscle activity at 2 min. Therefore, strengthening of the core muscles, thigh muscles of the lower extremities, and the upper extremities muscles is essential for CPR health care workers to ensure high-quality chest compression.35 Both strength and endurance are essential for high-quality CPR.5 Strength is important for achieving adequate depth of chest compressions, and endurance is essential for continuing CPR without becoming fatigued.5 The ventilatory threshold, which reflects the upper border of a working intensity that may be sustained for a prolonged period, is a reflection of endurance.5 In the study by Hansen et al, the authors found that it was the ventilatory threshold that determined the initial 5 min of CCR quality. In contrast, upper extremity muscle strength predicted CCR quality after the initial 5 min. This is because the ventilatory threshold loses its relationship to CCR quality rapidly over time, as the exercise level required during chest compressions is too high. When the findings of the included studies are considered collectively, despite variations in CPR quality definitions and assessment durations, a consistent physiological signal becomes evident. Studies assessing brief CPR performance as well as prolonged resuscitation consistently demonstrate that the ability to achieve and sustain adequate chest compression depth and rate is influenced by the rescuers’ capacity for force generation and fatigue resistance rather than by CPR training alone.1,4, 5, 6, 7,16, 17, 18 Studies incorporating direct measures of muscle strength, endurance, anaerobic capacity, and body composition showed that functional parameters, such as upper-body muscle strength, BCM, MM, TBW, upper-limb MM, and FFM, were associated with sustained CPR performance over time.6,8,17,20 This helps explain the nonlinear U-shaped associations observed between BMI and CPR quality, as BMI does not distinguish between muscularity and adiposity and therefore incompletely reflects the physical demands of CPR.16,31 Threading these disparate assessments together highlights an important gap in current resuscitation systems. Although CPR training programs and team-based models emphasize technical skills, protocols, and role allocation, they assume uniform physical capability among health care workers. The present synthesis suggests that this assumption may limit the consistency of high-quality CPR, particularly during prolonged resuscitation efforts where fatigue-related decay in compression quality is well documented.6,17,19 From a systems perspective, this evidence supports the need for health-care settings to consider interventions beyond traditional training, including physical preparedness and targeted conditioning focused on the strength and endurance of muscle groups crucial for CPR delivery.5,6,20 Such an approach aligns CPR workforce preparedness with the physiological demands demonstrated across the included studies and provides a pathway to address a previously insufficiently examined determinant of CPR quality. Across the included literature, compression depth was the CPR quality component frequently affected by fatigue and the physical health parameter of health care workers.1,4, 5, 6,16,17,30 These findings suggest that compression depth represents an important area for focused education and training, with particular emphasis on ergonomics, body positioning, and timely rotation to mitigate fatigue-related deterioration in performance.4, 5, 6,17,30 Thus, clinical teams should select individuals who are physically capable of performing high-quality CPR, even during prolonged resuscitation. This consideration is even more relevant in settings where the “Code Blue Team” of CPR health care workers often must rush to the distant hospital site to initiate CPR, often under physical exertion and time pressure.36 In conclusion, this review highlights that the physical health of CPR health care workers is crucial to ensuring high-quality CPR. Although BMI was frequently associated with CPR performance, it does not distinguish between MM and FM. Achieving adequate depth and sustained frequency of chest compressions requires both strength and endurance among CPR health care workers, and studies assessing muscle strength, endurance, and body composition have shown that these functional parameters may be more meaningful contributors to sustained high-quality CPR. Incorporating such considerations into CPR training and team planning may ensure the sustainability of high-quality CPR during prolonged resuscitation. Author Contributions PP, SC, and VKS contributed to the study design and conceptualization. Material preparation, data interpretation, and presentation were performed by PP, SC, VKS, KRN, ESD, and ASB. The first draft of the manuscript was performed by PP, SC, VKS, ASB, and KRN. Manuscript designing and editing were carried out by PP, SC, VKS, KRN, ESD, ASB, and DRP. All the authors reviewed and approved the final version of the manuscript. Funding and Support By JACEP Open policy, all authors are required to disclose any and all commercial, financial, and other relationships in any way related to the subject of this article as per ICMJE conflict of interest guidelines (see www.icmje.org). The authors have stated that no such relationships exist. Conflict of Interest All authors have affirmed they have no conflicts of interest to declare. Footnotes Supervising Editor: Matthew Hansen, MD, MCR Supplementary material associated with this article can be found in the online version at https://doi.org/10.1016/j.acepjo.2026.100395. Supplementary Materials Supplementary File 1 Supplementary File 2 Supplementary File 3 Supplementary Table S1 Supplementary Table Appendix 6 References Associated Data Supplementary Materials Supplementary File 1 Supplementary File 2 Supplementary File 3 Supplementary Table S1 Supplementary Table Appendix 6