Medial Open-Wedge High Tibial Osteotomy for Double Varus Deformity and an Increased Tibial Slope Authors: Wolf Petersen, Yizhou Ge, Amelie Klaumünzer, Martin Häner Published: 2025 ABSTRACT The goal of the modified medial open-wedge high tibial osteotomy is the combined correction of a double varus deformity (mechanical medial proximal tibia angle <84°, joint line convergence angle >2°) and an increased posterior tibial slope >12°. This goal can be achieved through a few modifications to the standard biplanar medial open-wedge high tibial osteotomy technique. These modifications include (1) positioning of the hinge anterolaterally and above the fibula, (2) removing a small anterior wedge, and (3) using Schanz screws to facilitate slope correction. Osteosynthesis is performed with a locking plate. Rehabilitation involves 6 weeks of partial weight-bearing and free range of motion. The stability of the knee joint depends on the ligamentous stabilizers as well as on the osseous joint geometry.1, 2, 3, 4, 5, 6, 7, 8, 9, 10 Biomechanical studies have shown that an increase in the posterior tibial slope (PTS) under load leads to increased anterior translation of the tibia and thus to increased stress on the anterior cruciate ligament (ACL).1,2,6,8, 9, 10 Clinical studies have verified these results.1,2,8,10 Accordingly, a PTS of more than 12° is associated with a significantly increased risk of recurrent instability after ACL reconstruction.10, 11, 12, 13 Therefore, both parameters in combination (recurrent instability and PTS >12°) are considered indication criteria for correcting the reclination of the tibial plateau before a second ACL reconstruction6,9,10,14,15 (Fig 1).Fig 1(A) Left leg, full-leg radiograph showing a hip-knee-ankle angle of 8°, an medial proximal tibia angle of 83°. (B) Left knee, close-up view of the knee joint showing a joint line convergence angle of 2,9° and slight medial joint space narrowing. (C) Long lateral radiograph of the entire tibia showing a posterior tibial slope of 13.8° (green line) (Left knee). (A) Left leg, full-leg radiograph showing a hip-knee-ankle angle of 8°, an medial proximal tibia angle of 83°. (B) Left knee, close-up view of the knee joint showing a joint line convergence angle of 2,9° and slight medial joint space narrowing. (C) Long lateral radiograph of the entire tibia showing a posterior tibial slope of 13.8° (green line) (Left knee). In addition, a double varus deformity—defined as a combination of an osseous and ligamentous varus deformity—can significantly increase the load in the medial compartment but also lead to overloading of the lateral ligamentous structures.10,12 This can lead to an accelerated development of posttraumatic medial osteoarthritis and to recurrent instability after ACL reconstruction (Fig 1). Modified medial open-wedge high tibial osteotomy (MOW HTO) is an ideal surgical technique for correcting varus deformity.16, 17, 18, 19 However, as a result of 3-dimensional geometry of the proximal tibia, this surgical technique tends to increase rather than decrease PTS.19, 20, 21, 22, 23, 24 Recent studies have shown, however, that the orientation of the lateral hinge and the osteotomy plane play an important role in the effect of MOW-HTO on PTS.23, 24, 25, 26 Thus, with an anterolateral hinge position, a reduction in PTS is also possible with MOW-HTO.23,24 On the basis of these findings, we have developed a modified MOW HTO technique that allows for adequate correction of both PTS and varus deformity. The main modifications to the MOW-HTO technique originally described by Staubli et al.19 include (1) positioning of the hinge anterolaterally and above the fibula, (2) removing a small anterior wedge, and (3) using Schanz screws to facilitate slope correction (Fig 2). The aim of this article is to describe this surgical technique.Fig 2The main modifications to the medial open-wedge high tibial osteotomy technique originally described by Staubli et al.19 Shifting the hinge anterolaterally (A), placing the hinge above the fibula head (B), removing a small anterior wedge (C), and using Schanz screws to facilitate slope correction (D). The main modifications to the medial open-wedge high tibial osteotomy technique originally described by Staubli et al.19 Shifting the hinge anterolaterally (A), placing the hinge above the fibula head (B), removing a small anterior wedge (C), and using Schanz screws to facilitate slope correction (D). Surgical Technique Advantages/Disadvantages and Preoperative Planning Advantages/disadvantages for the modified MOW HTO are listed in Table 1.14 Table 2 shows the surgical instruments needed. Figure 3 shows the preoperative planning.3Table 1Advantages and Disadvantages for the Modified Medial Open-Wedge High Tibial OsteotomyAdvantagesDisadvantages•Addressing multiple pathologies in a single operation, thereby reducing rehabilitation time•Technicaslly demanding procedure with a risk of hinge fractureTable 2Surgical Instruments Needed for the Modified Medial Open-Wedge High Tibial OsteotomyGuidewiresRadiolucent Hohmann retractorImage intensifierOscillating sawLarge Lambotte chiselOsteotomy spreaderSchanz screwsAngular stable high tibial osteotomy plateFig 3(A) Preoperative planning according to the method specified by Miniaci et al.27 The current mechanical axis (M1). The planned new mechanical axis (M2) runs approximately through the center of the knee joint (approximately 50% of the knee baseline). The osteotomy begins medially approximately 30 mm below the tibial plateau, ascends obliquely, and ends just above the fibula head. approximately 10 mm below the articular surface medially. (B) Enlarged section of the knee joint from (A). Knowing the osteotomy length (green line and green dotted line, the wedge height (red WH) can be determined at the auxiliary lines (red line L1 and L2). Table 1Advantages and Disadvantages for the Modified Medial Open-Wedge High Tibial OsteotomyAdvantagesDisadvantages•Addressing multiple pathologies in a single operation, thereby reducing rehabilitation time•Technicaslly demanding procedure with a risk of hinge fracture Advantages and Disadvantages for the Modified Medial Open-Wedge High Tibial Osteotomy •Addressing multiple pathologies in a single operation, thereby reducing rehabilitation time Addressing multiple pathologies in a single operation, thereby reducing rehabilitation time •Technicaslly demanding procedure with a risk of hinge fracture Technicaslly demanding procedure with a risk of hinge fracture Table 2Surgical Instruments Needed for the Modified Medial Open-Wedge High Tibial OsteotomyGuidewiresRadiolucent Hohmann retractorImage intensifierOscillating sawLarge Lambotte chiselOsteotomy spreaderSchanz screwsAngular stable high tibial osteotomy plate Surgical Instruments Needed for the Modified Medial Open-Wedge High Tibial Osteotomy (A) Preoperative planning according to the method specified by Miniaci et al.27 The current mechanical axis (M1). The planned new mechanical axis (M2) runs approximately through the center of the knee joint (approximately 50% of the knee baseline). The osteotomy begins medially approximately 30 mm below the tibial plateau, ascends obliquely, and ends just above the fibula head. approximately 10 mm below the articular surface medially. (B) Enlarged section of the knee joint from (A). Knowing the osteotomy length (green line and green dotted line, the wedge height (red WH) can be determined at the auxiliary lines (red line L1 and L2). Patient Positioning The operation is performed in the supine position and begins with an examination of the knee joint stability under anaesthesia (ligamentous status and range of motion). Then, a tourniquet is applied, and the injured leg is draped in the usual sterile manner. Placing the leg in a movable, motorized leg holder facilitates the operation. Preoperatively the patient receives 1 g of tranexamic acid to prevent bleeding from the osteotomy gap.28 Arthroscopy An arthroscopy is performed to diagnose and treat accompanying intra-articular damage such as meniscus and cartilage lesions. Depending on the state of the bone tunnels the MOW HTO can also be combined with ACL reconstruction or bone grafting of the tunnels.29 Osteotomy For surgical approach and osteotomy, the knee is in a flexed position (approximately 45°) to protect the neurovascular structures of the popliteal fossa (Fig 4). After draping and skin disinfection, an approximately 10-cm long incision medial of the tibial tuberosity is made to expose the hamstring tendons, the superficial medial collateral ligament, and the patella tendon (Fig 5).Fig 4Patient in supine position, left knee. An approximately 10=cm long incision (dotted line) medial of the tibial tubercle (TT, white arrow). For the osteotomy, the knee is in approximately 45◦ flexion to better retract the neurovascular structures dorsally with the Hohmann retractor. (P, patella.)Fig 5Patient in supine position, left knee. Exposure of the patellar tendon (PT), the hamstrings (H), and the superficial medial collateral ligament (sMCL) (white arrow). The tibial button of the previous anterior cruciate ligament reconstruction becomes visible. (P, patella.) Patient in supine position, left knee. An approximately 10=cm long incision (dotted line) medial of the tibial tubercle (TT, white arrow). For the osteotomy, the knee is in approximately 45◦ flexion to better retract the neurovascular structures dorsally with the Hohmann retractor. (P, patella.) Patient in supine position, left knee. Exposure of the patellar tendon (PT), the hamstrings (H), and the superficial medial collateral ligament (sMCL) (white arrow). The tibial button of the previous anterior cruciate ligament reconstruction becomes visible. (P, patella.) A Hohmann retractor is placed between the patellar tendon and the tibial tuberosity and the superficial medial collateral ligament is undermined with a raspatorium and a radiolucent Hohmann retractor is placed behind the posterior tibial cortex to protect the neurovascular structures of the popliteal fossa (Figs 6 and 7). Then 2 guidewires are drilled from the medial to the lateral cortex of the proximal tibia under the control of the fluoroscope (Figs 7 and 8). The medial entry point is approximately 8 mm above the hamstring tendons. The tip of the guidewire should reach the lateral cortex just above the tip of the fibula. The osteotomy plane should be perpendicular to the sagittal tibial axis avoiding the tibial tubercle. The intraosseous length of the wires must be determined using a special measuring gauge to estimate how far the osteotomy can be performed with the oscillating saw without damaging the anterolateral hinge (Fig 9). Then 2 Schanz screws are applied, one above and one below the osteotomy plane.Fig 6Patient in supine position, left knee. The medial collateral ligament is first passed under with the periosteal elevator (white arrow) and the distal fibers are detached. (H, hamstrings; P, patella; PT, patella tendon; sMCL, superficial medial collateral ligament; TT, tibial tubercle.)Fig 7Patient in supine position, left knee. A Hohmann retractor is inserted behind the posterior tibial cortex at the level of the planned osteotomy and the first guidewire (white arrow) is drilled into the proximal tibia starting approximately 8 mm above the hamstring tendons (H). The bone tunnel is marked with another K wire (black arrow). (P, patella; PT, patella tendon; TT, tibial tubercle.)Fig 8Patient in supine position, left knee. A second 2.5-mm thick Kirschner wire is drilled parallel and obliquely ascending into the proximal tibia using a parallel drill guide (white arrow). (P, patella; PT, patella tendon; TT, tibial tubercle.)Fig 9Patient in supine position, left knee. The intraosseous length of the wires must be determined using a special measuring gauge to estimate how far the osteotomy can be performed with the oscillating saw to leave the anterolateral hinge intact (white arrow). (PT, patella tendon; TT, tibial tubercle.) Patient in supine position, left knee. The medial collateral ligament is first passed under with the periosteal elevator (white arrow) and the distal fibers are detached. (H, hamstrings; P, patella; PT, patella tendon; sMCL, superficial medial collateral ligament; TT, tibial tubercle.) Patient in supine position, left knee. A Hohmann retractor is inserted behind the posterior tibial cortex at the level of the planned osteotomy and the first guidewire (white arrow) is drilled into the proximal tibia starting approximately 8 mm above the hamstring tendons (H). The bone tunnel is marked with another K wire (black arrow). (P, patella; PT, patella tendon; TT, tibial tubercle.) Patient in supine position, left knee. A second 2.5-mm thick Kirschner wire is drilled parallel and obliquely ascending into the proximal tibia using a parallel drill guide (white arrow). (P, patella; PT, patella tendon; TT, tibial tubercle.) Patient in supine position, left knee. The intraosseous length of the wires must be determined using a special measuring gauge to estimate how far the osteotomy can be performed with the oscillating saw to leave the anterolateral hinge intact (white arrow). (PT, patella tendon; TT, tibial tubercle.) To lower the PTS, it is necessary to open the osteotomy gap posteriorly.23, 24, 25 For this, the hinge position must be anterolateral. Therefore, the osteotomy along the guide wires should only be performed incompletely (approximately 70%-80%) with the oscillating saw. A complete osteotomy of the posterior cortex is best achieved with a chisel, as this avoids vascular injuries caused by the saw's deflection. The anterolateral hinge can also be protected by a hinge wire inserted in the area of the anterolateral tibial margin. (Fig 10, Fig 11, Fig 12, Fig 13, Fig 14, Fig 15).Fig 10Patient in supine position, left knee. From the lateral side, a so-called hinge wire (white arrow) is placed under fluoroscopic control from the tibial rim obliquely downwards in the anterolateral area of the tibia to protect the hinge.Fig 11Patient in supine position, left knee. (A) The intraosseous length minus 10 mm is marked on the oscillating saw (white arrow). (B) The osteotomy is then performed below the 2 guidewires. The osteotomy should be performed with the oscillating saw only incompletely (black arrow), up to approximately 70% to 80%, to prevent transection of the osteotomy hinge. During osteotomy, the saw should be cooled with irrigating fluid. (P, patella; PT, patella tendon; TT, tibial tubercle.)Fig 12Patient in supine position, left knee. To facilitate anterior rotation of the proximal fragment, it is recommended to remove an anterior wedge. (A) For this purpose, an initial ascending osteotomy is performed toward the infrapatellar bursa using an oscillating saw (white arrow). (B) This osteotomy gap is then marked with a saw blade (black arrow). (C) A second osteotomy is then performed slightly further anteriorly at a slightly upward angle, and the wedge is removed (yellow arrow). P, patella; PT, patella tendon.)Fig 13Graphic representation of the anterior wedge removal. (F, femur; G, gracilis tendon; MCL, medial collateral ligament; P, patella; PT, patellar tendon; QT, quadriceps tendon; ST, semitendinosus tendon; T, tibia; TT, tibial tubercle.)Fig 14Patient in supine position, left knee. (A) Before the osteotomy is completed, Schanz screws (white arrows) are inserted proximal and distal to the osteotomy to facilitate the rotation of the proximal fragment. To shift the osteotomy hinge anterolaterally, a complete transection of the posterior cortex is necessary. Because of the oscillating saw's deflections, there is a risk of damage to the neurovascular structures in the popliteal fossa region if the posterior tibial cortex is completely transected. Therefore, we recommend transecting the posterior cortex with an osteotomy chisel (cold osteotomy). The lateral cortex should be left intact anterolaterally to shift the osteotomy hinge anterolaterally. (B) The position of the osteotomy chisel should be checked with the image intensifier. The chisel tip protrudes slightly beyond the lateral tibial cortex.Fig 15Graphic representation of the posterior osteotomy with the chisel (black arrow). (T, tibia.) Patient in supine position, left knee. From the lateral side, a so-called hinge wire (white arrow) is placed under fluoroscopic control from the tibial rim obliquely downwards in the anterolateral area of the tibia to protect the hinge. Patient in supine position, left knee. (A) The intraosseous length minus 10 mm is marked on the oscillating saw (white arrow). (B) The osteotomy is then performed below the 2 guidewires. The osteotomy should be performed with the oscillating saw only incompletely (black arrow), up to approximately 70% to 80%, to prevent transection of the osteotomy hinge. During osteotomy, the saw should be cooled with irrigating fluid. (P, patella; PT, patella tendon; TT, tibial tubercle.) Patient in supine position, left knee. To facilitate anterior rotation of the proximal fragment, it is recommended to remove an anterior wedge. (A) For this purpose, an initial ascending osteotomy is performed toward the infrapatellar bursa using an oscillating saw (white arrow). (B) This osteotomy gap is then marked with a saw blade (black arrow). (C) A second osteotomy is then performed slightly further anteriorly at a slightly upward angle, and the wedge is removed (yellow arrow). P, patella; PT, patella tendon.) Graphic representation of the anterior wedge removal. (F, femur; G, gracilis tendon; MCL, medial collateral ligament; P, patella; PT, patellar tendon; QT, quadriceps tendon; ST, semitendinosus tendon; T, tibia; TT, tibial tubercle.) Patient in supine position, left knee. (A) Before the osteotomy is completed, Schanz screws (white arrows) are inserted proximal and distal to the osteotomy to facilitate the rotation of the proximal fragment. To shift the osteotomy hinge anterolaterally, a complete transection of the posterior cortex is necessary. Because of the oscillating saw's deflections, there is a risk of damage to the neurovascular structures in the popliteal fossa region if the posterior tibial cortex is completely transected. Therefore, we recommend transecting the posterior cortex with an osteotomy chisel (cold osteotomy). The lateral cortex should be left intact anterolaterally to shift the osteotomy hinge anterolaterally. (B) The position of the osteotomy chisel should be checked with the image intensifier. The chisel tip protrudes slightly beyond the lateral tibial cortex. Graphic representation of the posterior osteotomy with the chisel (black arrow). (T, tibia.) Then, 2 ascending slightly diverging osteotomies towards the infrapatellar bursa are carried out to remove a small anterior wedge (Figs 12 and 13). The complete posterior osteotomy and removal of this anterior wedge facilitate the anterior rotation of the proximal tibia. The osteotomy gap is then spread using 3 wide Lambotte chisels inserted one after the other. When the planned osteotomy height is roughly reached, the chisels are replaced by an osteotomy spreader, which is placed at the posterior cortex with the knee in full extension. This allows fine adjustment of the correction. The posterior slope should also be corrected by pressing the 2 Schanz screws together anteriorly (Fig 16). The slope correction can optionally be secured by temporarily connecting the 2 Schanz screws using an external fixator.Fig 16Patient in supine position, left knee. Spreading the osteotomy gap. (A) To spread the osteotomy gap, the knee should be in full extension. First, 3 wide Lambotte chisels are inserted into the osteotomy gap one after the other, slowly spreading it. When the planned wedge height has been approximately reached, the chisels are replaced with an osteotomy spreader, which is inserted into the posterior cortex at the back of the osteotomy (white arrow) (B-C) The spreader is used to finally adjust the planned gap height. The Schanz screws are manually brought together (black lines) to rotate the proximal fragment anteriorly and reduce the posterior slope. Patient in supine position, left knee. Spreading the osteotomy gap. (A) To spread the osteotomy gap, the knee should be in full extension. First, 3 wide Lambotte chisels are inserted into the osteotomy gap one after the other, slowly spreading it. When the planned wedge height has been approximately reached, the chisels are replaced with an osteotomy spreader, which is inserted into the posterior cortex at the back of the osteotomy (white arrow) (B-C) The spreader is used to finally adjust the planned gap height. The Schanz screws are manually brought together (black lines) to rotate the proximal fragment anteriorly and reduce the posterior slope. After correction in the sagittal and frontal plane, the new mechanical axis and tibial slope is checked with a metal rod and an image intensifier. The aim is to correct the new mechanical axis between 50% and 55% of the tibial joint line (Fig 16). Once the desired correction has been achieved, an angle-stable osteosynthesis plate (eg, aap Implantate AG, Berlin, Germany) is temporarily fixed with a K-wire and the position of the osteosynthesis plate is checked with the image intensifier. The proximal screws should be placed approximately 10 mm below the tibial articular surface and extend into the medial third of the tibial plateau. After osteosynthesis is complete tibial slope and the final plate position are checked with the image intensifier and the wound is closed (Fig 17). The rehabilitation protocol includes partial weight-bearing with 10 kg for 6 weeks and free range of motion. Figure 18 is showing the postoperative radiograph control of leg axis, PTS, and implant position.Fig 17After spreading the osteotomy osteosynthesis is performed with an angle-stable plate (eg, Loqtech HTO Plate [aap Implantate AG] black arrow). Anteroposterior view of the fluoroscopic control of the plate position after the osteosynthesis is complete.Fig 18Postoperative radiograph control of leg axis, PTS, and implant position. (A) Full-leg radiograph with neutral leg axis (green line). (B) Lateral view of the tibia with a PTS of 8.0° (green line). (PTS, posterior tibial slope.) After spreading the osteotomy osteosynthesis is performed with an angle-stable plate (eg, Loqtech HTO Plate [aap Implantate AG] black arrow). Anteroposterior view of the fluoroscopic control of the plate position after the osteosynthesis is complete. Postoperative radiograph control of leg axis, PTS, and implant position. (A) Full-leg radiograph with neutral leg axis (green line). (B) Lateral view of the tibia with a PTS of 8.0° (green line). (PTS, posterior tibial slope.) Pearls and pitfalls of this procedure are shown in Table 3.Table 3Pearls and Pitfalls of Medial Open-Wedge High Tibial OsteotomyPearlsPitfalls•Use of radiolucent Hohmann retractors•Use of a hinge wire•Injury to the vessels in the popliteal fossa area•Hinge fracture•Over- or undercorrection Table 3Pearls and Pitfalls of Medial Open-Wedge High Tibial OsteotomyPearlsPitfalls•Use of radiolucent Hohmann retractors•Use of a hinge wire•Injury to the vessels in the popliteal fossa area•Hinge fracture•Over- or undercorrection Pearls and Pitfalls of Medial Open-Wedge High Tibial Osteotomy •Use of radiolucent Hohmann retractors Use of radiolucent Hohmann retractors •Use of a hinge wire Use of a hinge wire •Injury to the vessels in the popliteal fossa area Injury to the vessels in the popliteal fossa area •Hinge fracture Hinge fracture •Over- or undercorrection Over- or undercorrection Discussion In this Technical Note, we present a modified MOW HTO technique for frontal and sagittal deformity correction. The classic MOW HTO as described by Staubli et al.19 tends to increase the PTS because the procedure inherently involves opening the medial side of the tibia while using the lateral or posterolateral cortex as a hinge.21,25 This hinge mechanism causes the proximal tibial segment to rotate, which can accentuate the posterior tilt of the tibial plateau, especially if the posterior cortex is not adequately cut during the procedure.21,25 Recent research has demonstrated, that consequently, when the hinge is positioned anterolaterally, MOW HTO can also result in a reduction of PTS.22,25 However, this modification presents a surgical challenge, as it requires a complete transection of the posterior cortex which carries a risk of vascular injury due to the oscillating saw's deflections. For this reason, we use a special Lambotte chisel with rounded corners for the posterior osteotomy. A hinge wire is suitable for protecting the anterolateral hinge. This has proven effective in biomechanical and clinical studies for protecting the osteotomy hinge.24 Because the rotation of the proximal fragment in the sagittal plane can blocked anteriorly, additionally small anterior wedge is removed. This significantly facilitates slope correction. The use of Schanz screws also serves this purpose. In summary, the technique described here is ideal for the correction of frontal and sagittal instabilities in combination with anterolateral instability. Disclosures The authors declare the following financial interests/personal relationships which may be considered as potential competing interests: W.P. reports consulting or advisory, speaking and lecture fees, and travel reimbursement with Arthrex, Karl Storz, aap Implantate AG, and OPED. All other authors (Y.G., A.K., M.H.) declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.