Prefabricated 3D-printed full-arch implant for functional and esthetic rehabilitation: a prosthesis-integrated drill guide solution Authors: Hao Bai, Wenyan Wu, Xuejun Ge, Zhen Wang Published: 2025 ABSTRACT AbstractBackgroundImmediate-loading full-arch implant restoration offers improved patient comfort and acceptance but poses challenges in implant positioning, especially for complex anatomical conditions. Fully digital workflows, including intraoral scans and 3D-printed guides, enhance precision but may still result in cumulative errors affecting prosthetic fit. This study introduces a modified digital protocol integrating prefabricated prostheses with drill guides to improve accuracy and simplify full-arch rehabilitation.MethodsA systematic step-by-step protocol was developed using digital simulation and virtual design to fabricate prefabricated prostheses. These prostheses, combined with surgical drill templates, allowed for immediate functional and esthetic loading. Integration of the provisional restoration with the drill guide was designed to reduce discrepancies during prosthesis repositioning when securing pre-cut temporary cylinders with resin.ResultsThe proposed workflow demonstrated high accuracy in prosthesis placement, reducing repositioning errors during the clinical procedure. Functional and esthetic loading was successfully achieved, with precise alignment of components and a streamlined digital workflow.ConclusionsThis digital approach provides an effective and cost-efficient solution for immediate full-arch implant loading. By enhancing accuracy and minimizing procedural errors, it offers improved clinical outcomes and sets a foundation for advanced full-arch rehabilitation techniques. Introduction Currently, immediate-loading full-arch implant restoration has become a routine practice for edentulous patients. Compared to conventional implant restoration protocols, the immediate-loading approach—featuring a fixed, chairside, implant-supported interim restoration followed by a titanium-milled frame prosthesis—demonstrates improved patient acceptance and comfort when evaluated after 3 months [1, 2]. Techniques such as distal tilted, zygomatic, and pterygoid implants expand treatment options in cases of severe bone atrophy. However, accurate placement of long, angled implants remains challenging due to anatomical complexity and the proximity of vital structures. To address these challenges, fully digital workflows have been developed, integrating CBCT, intraoral and facial scans, digital articulators, and 3D printing. A fully digital workflow, including 3D-printed surgical templates and provisional prosthetics aligned with anchor pins, are the general commercial procedures for full-arch implant restoration. From preoperative data collection to virtual design and realistic rendering, digitally guided implant surgery combined with prefabricated prostheses allows for the precisely transfer of esthetic and functional information—synthesized and simulated by software—directly to the patient, leading to more favorable outcomes. Although discrepancies between the actual implant position and the virtual simulation may occasionally occur, full-arch guided implant surgery has consistently proven to be a predictable method for implant placement [3]. Alternatively, tooth-supported full-arch implant guides may provide more accuracy for partially edentulous patients compared to fully edentulous patients, with the number of remaining teeth being a significant factor in this difference [4]. Cumulative errors throughout the workflow—ranging from data acquisition to final prosthesis delivery—can compromise fit and occlusion. While enlarging prosthetic channels can improve tolerance, this may weaken prosthesis strength and occlusal accuracy. Nevertheless, in some patients, unexpected deviations in surgical implant placement can prevent the interim prosthesis from being properly positioned and fixed. Moreover, enlargement of the fitting channels may diminish the strength and deplete the occlusal anatomy of the interim prosthesis. The purpose of the present article is to describe a modified, step-by-step, digitally planed, immediate implant-guided full-arch implant loading protocol. In this approach, a tooth-supported surgical guide is used to position the anchor pin at the beginning of surgery. The guided drilling and implant insertion are performed by an integrated solution involving prosthetics and a full or pilot drill implant guide, which means that the prefabricated prosthesis functions as an implant guide as well. This technique may improve the positioning and fixation of prefabricated prostheses and increase the success rate of the overall procedure for full-arch implant restoration. Technique Clinical examination and digital data acquisition Clinical evaluation of the number and condition of the patient’s remaining teeth, temporomandibular joint (TMJ) mobility during functional movements, and exclusion of severe systematic diseases and other contradictions. This protocol is applicable to patients meeting the general criteria for immediate implant placement and loading. (Fig. 1A, B) Clinical evaluation of the number and condition of the patient’s remaining teeth, temporomandibular joint (TMJ) mobility during functional movements, and exclusion of severe systematic diseases and other contradictions. This protocol is applicable to patients meeting the general criteria for immediate implant placement and loading. (Fig. 1A, B) Data collection including CBCT scans, digital photographs and facial scans were imported into Exocad dental planning software (Exocad GmbH, Darmstadt, Germany). A specific integration and superimposition algorithm were run to match the 3D data. Data collection including CBCT scans, digital photographs and facial scans were imported into Exocad dental planning software (Exocad GmbH, Darmstadt, Germany). A specific integration and superimposition algorithm were run to match the 3D data. A, Facial frontal view. B, C, Facial lateral view (Left). D, Intraoral lateral view (Right). E, Intraoral frontal view. F, Intraoral lateral view (Left) Virtual simulation and design 3.All aligned virtual models were mounted onto a virtual fully adjustable articulator, and erasure of the remaining teeth and digital arrangement of the teeth were precisely completed in accordance with the comprehensive esthetic and functional data (Fig. 2A, B). All aligned virtual models were mounted onto a virtual fully adjustable articulator, and erasure of the remaining teeth and digital arrangement of the teeth were precisely completed in accordance with the comprehensive esthetic and functional data (Fig. 2A, B). 4.The detachable 3D-printed drill guide rings were designed with specialized positioning slots that extend above the occlusal plane when inserted into the prosthesis. Both the anchor pin template and the prosthesis were aligned using the same bone sites for precise placement. (Fig. 2C, D). The detachable 3D-printed drill guide rings were designed with specialized positioning slots that extend above the occlusal plane when inserted into the prosthesis. Both the anchor pin template and the prosthesis were aligned using the same bone sites for precise placement. (Fig. 2C, D). 5.The lower jaw provided sufficient space for the planned restoration, allowing for the direct incorporation of a fixed inner pilot drill guide within the prosthesis (Fig. 2C, D). The lower jaw provided sufficient space for the planned restoration, allowing for the direct incorporation of a fixed inner pilot drill guide within the prosthesis (Fig. 2C, D). 6.The number and placement of the implants were prosthetically planned to adhere to the requirements and principles of implant-supported fixed full-arch rehabilitation (Fig. 2E, F). The number and placement of the implants were prosthetically planned to adhere to the requirements and principles of implant-supported fixed full-arch rehabilitation (Fig. 2E, F). A, Digital model with virtual occlusion registration data was import into Exocad and then a pair of edentulous models were built by digitally erased the remain teeth. B, Digital facebow data was utilized to mount the oral-scan and face scan model onto the fully adjustable virtual articulator. C, D, After virtual depletion of the remain teeth and functional esthetical teeth arrangement, anchor pins template and prefabricated pilot drill guide contained in prosthesis were virtually designed. E, F, Virtual implant placement simulated according to the prosthetic design Manufacture of the surgical template and prosthetics by 3D-printing 7.Putty silicone rubber was used to register the position of the surgical template, facilitating the next steps of the procedure and allowing for observation of the restorative space (Fig. 3A, B, C). Putty silicone rubber was used to register the position of the surgical template, facilitating the next steps of the procedure and allowing for observation of the restorative space (Fig. 3A, B, C). 8.The detachable drill guide rings were carefully inspected to ensure precise placement within the designated slots of the poly (methyl methacrylate) (PMMA) prosthesis (Fig. 3D, E, F, G, H, I). The detachable drill guide rings were carefully inspected to ensure precise placement within the designated slots of the poly (methyl methacrylate) (PMMA) prosthesis (Fig. 3D, E, F, G, H, I). A, Drill templates located by anchor pins on the modified 3D printed models mounted on a full adjustable articulator. B, Prefabricated prosthesis located by anchor pins on the modified 3D printed models mounted on a full adjustable articulator. C, Vertical dimension and the relative position between the upper jaw and lower jaw was shown on the modified 3D printed models. D, Occlusal view of anchor pins located prefabricated drill guided prosthesis. (Lower arch). E, Occlusal view of the pilot drill channel in the prosthesis. F, Occlusal view of anchor pins located prefabricated drill guided prosthesis. (Upper arch). G, Occlusal view of the positioning slot for the detachable drill guide in the prosthesis. H, The detachable pilot drill guide. I, Occlusal view of anchor pins located prefabricated prosthesis installed with detachable pilot drill guide. (Upper arch) Fully guided implantation and immediate loading 9.Following the administration of local anesthesia, the surgical anchor pin template was positioned on the remaining teeth, and pin holes were drilled. This was done in preparation for the subsequent steps (Fig. 4A). Following the administration of local anesthesia, the surgical anchor pin template was positioned on the remaining teeth, and pin holes were drilled. This was done in preparation for the subsequent steps (Fig. 4A). 10.After extracting all remaining teeth, the pilot drill guide prostheses was aligned with the same bone holes drilled using the template, and the occlusal status was verified to ensure the accuracy of the entire virtual simulation process (Fig. 4B). After extracting all remaining teeth, the pilot drill guide prostheses was aligned with the same bone holes drilled using the template, and the occlusal status was verified to ensure the accuracy of the entire virtual simulation process (Fig. 4B). 11.Pilot drill holes were created using the pilot drill guide—employing the detachable guide for the upper jaw and the direct guide for the prostheses in the lower jaw (Fig. 4C). Pilot drill holes were created using the pilot drill guide—employing the detachable guide for the upper jaw and the direct guide for the prostheses in the lower jaw (Fig. 4C). 12.The prosthesis was removed when the pilot drill holes were finished. Twelve implants (Straumann, Switzerland) were placed individually by free hand, ensuring that each implant was inserted with a minimum torque of 35 Ncm (Fig. 4D). The prosthesis was removed when the pilot drill holes were finished. Twelve implants (Straumann, Switzerland) were placed individually by free hand, ensuring that each implant was inserted with a minimum torque of 35 Ncm (Fig. 4D). 13.All the components of the drill guide in the prosthesis were removed, and modified titanium abutments were installed (Fig. 4E, F, G, H). All the components of the drill guide in the prosthesis were removed, and modified titanium abutments were installed (Fig. 4E, F, G, H). 14.The finalized prosthesis was immediately loaded (Fig. 4I). The finalized prosthesis was immediately loaded (Fig. 4I). A, Tooth-supported 3D printed anchor pins template was utilized for transferring the virtual planed pin-position to the jaws. B, Repositioning of the prosthesis by anchor pins in the same holes after removing the template. C, Pilot drilling was finished guided by the prefabricated drill guided prosthesis. D, All implants were place guided by the prosthesis as planned. E, High-speed rotary bur was applied to remove the guided structures. F, All the drill guide channels were modified into interim prosthesis fitting channels immediately after the implants placement. G, Interim prosthetics were repositioning and bonding to temporary titanium abutment utilizing acrylic resin. H, Final modification and relining. I, Immediate loading the finished interim prosthesis Replacement of the interim prosthesis and suture removal at the 1-week visit 15.Digital substitutes were attached extraorally and scanned with a laboratory laser scanner. Combined with intraoral mucosal scans, photogrammetry, and occlusal records, the final implant positions were digitally aligned to fabricate a second 3D-printed PMMA provisional prosthesis. Digital substitutes were attached extraorally and scanned with a laboratory laser scanner. Combined with intraoral mucosal scans, photogrammetry, and occlusal records, the final implant positions were digitally aligned to fabricate a second 3D-printed PMMA provisional prosthesis. 16.The immediate loading restoration was replaced, and the sutures under the prosthesis were removed. (Fig. 5A, B). The immediate loading restoration was replaced, and the sutures under the prosthesis were removed. (Fig. 5A, B). A, One-week post-operation front view. B, C, One-week post-operation Facial lateral view (Left). D, One-week post-operation intraoral lateral view (Right). E, One-week post-operation intra-oral view. F, One-week post-operation intraoral lateral view (Left) Results The technique was applied to a cohort of patients requiring immediate full-arch rehabilitation. All interim prostheses achieved a 100% successful intraoperative pick-up rate. During the follow-up period, all implants remained clinically stable and functional without signs of failure. The emergence of all screw access channels fell within the prosthetically planned positions, indicating high accuracy in implant placement and confirming the workflow’s clinical feasibility and reproducibility. Discussion Commercial procedures for fully digital workflows in immediate full-arch implant loading have become widely adopted and are undergoing rapid improvements. With constantly advancements in digital techniques, software and hardware updates, innovative guided implants and immediate loading solutions are emerging while existing methods continue to evolve [5, 6]. In addition to the stackable guide concept based on anchor pins, [5, 7] other techniques have been applied in digital workflows [6, 8]. Compared to standard commercial fully digital workflows, other techniques not only focus on minimizing accumulative errors in implant placement but also use new connective components or procedures, such as shape memory alloy abutment, to tolerate errors in locating the interim prostheses [8]. Our solution, which integrates prosthetics with full or pilot drill implant guides, provides a feasible and cost-effective technique for seamlessly transferring preoperative digital plans into the clinical workflow. The principles of prosthetically guided surgery are demonstrated through the use of a flexible, detachable guide ring design, combining the implant surgical guide and prosthesis into a single unit. This approach significantly reduces errors that typically arise from prosthesis repositioning after fully guided implantation using reference anchor pins. In edentulous cases, the prosthetic design can be appropriately modified to enhance stability and guidance. By integrating an anchor pin and detachable implant guide into a complete denture–like interim prosthesis, this workflow eliminates the need for a separate surgical template while maintaining high accuracy in implant placement and enabling immediate loading. Despite its favorable intraoperative performance, the current technique is limited to drill guidance and does not constitute a fully guided surgical protocol. Future developments may focus on modular guide components to achieve comprehensive guidance throughout the procedure, thereby improving precision and clinical reliability. Moreover, long-term clinical studies are warranted to evaluate the prognosis and generalizability of this technique. Summary The prefabricated, digitally planned, 3D-printed prosthesis with integrated pilot drill guidance is a feasible solution that maximally maintains both esthetic and functional effects for full-arch implant rehabilitation patients. This technique simplifies the overall surgical and immediately restorative procedures inexpensively and precisely. Acknowledgements Not applicable. Author contributions Hao and Wenyan wrote the main manuscript text. Hao Bai and Dr. Wenyan Wu contributed equally to this work. Xuejun Ge and Zhen Wang contributed equally as corresponding authors. Xuejun and Zhen conceptualization and supervision of this study. Both were responsible for the overall experimental design and provided key intraoperative and illustrative images. All authors reviewed the manuscript. Funding This work was sponsored by the Interdisciplinary Program of Shanghai Jiao Tong University (project No. YG2022QN054). Data availability No datasets were generated or analysed during the current study. Declarations Ethical approval All procedures were conducted following institutional guidelines, and written informed consent was obtained from all patients involved in this study.Ethical approval for this technical report was obtained from the Ethics Committee Review Board of Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine (Approval Number: SH9H-2024-T212 Consent for publication Not applicable. Competing interests The authors declare no competing interests. Footnotes Publisher’s note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations. Hao Bai and Wenyan Wu contributed equally to this work. Contributor Information Xuejun Ge, Email: gxj19722003@163.com. Zhen Wang, Email: pmxcl@me.com. References Associated Data Data Availability Statement No datasets were generated or analysed during the current study.