RecombiCraft library construction: A novel method for DNA library cloning and expansion using non-enzymatic single-step DNA recombination and liquid culture Authors: Yuki Kawai-Harada, Mehrsa Mardikoraem, Katherine Lauro, Vasudha Nimmagadda, Quynh Tong, Kayla Bello, Daniel Woldring, Masako Harada, Md Rajib Sharker, Md Rajib Sharker, Md Rajib Sharker Published: 2024 ABSTRACT In this study, we introduce RecombiCraft, an innovative, rapid, and cost-efficient method for constructing DNA libraries in E. coli. This method uses seamless ligation cloning extract (SLiCE) coupled with liquid culture amplification to effectively minimize sequence biases. The technique capitalizes on the natural homologous recombination capabilities of E. coli cell lysates, eliminating the need for multiple purified enzymes and reducing costs. We first synthesized the library backbone and inserts via PCR, employing high-fidelity polymerase to minimize sequence bias. The SLiCE technique was then used to assemble the DNA fragments introduced into E. coli through electroporation. To ensure the integrity of the library, we optimized culture times based on next-generation sequencing analysis which confirmed the minimal sequence bias. The RecombiCraft method demonstrates that this approach is economical and maintains the library’s uniformity. By using liquid culture, this method can complete DNA library generation in about 12 hours and final extraction is simple, making it a promising tool for genetic research and biotechnology applications. Introduction DNA libraries play a pivotal role in modern biological research by providing comprehensive collections of genetic information essential for understanding the complexities of life. These libraries serve as tools for elucidating gene function, regulatory mechanisms, and disease pathways, thereby facilitating the discovery of new drugs and biotechnological innovations [1]. The diversification of DNA libraries is achieved through natural, synthetic, or semi-synthetic methods. Traditional natural libraries are composed of genetic material from a variety of sources, including humans and other mammals, selected based on specific attributes such as age, phenotype, or immunization status for antibody libraries [2]. Synthetic libraries, on the other hand, are derived from pre-existing genetic templates modified through either random or directed mutations. Techniques like error-prone PCR intentionally reduce polymerase accuracy to induce mutations broadly across the genome [3, 4], while strategies such as chain shuffling rearrange the sequence order [5, 6]. Targeted approaches involve modifications of specific sequences or regions, often utilizing degenerate oligonucleotides for targeted changes [7–9]. Nicking mutagenesis is a modern technique that introduces specific mutations into DNA by creating nicks in one strand and using them as starting points for targeted changes during replication or repair [10]. The integration of DNA fragments from these libraries into a backbone is generally categorized into two main strategies: 1) those employing restriction enzyme sites, and 2) those leveraging the homology between the insert and backbone. Common examples of the first category include techniques like Golden Gate Assembly and blunt-end cloning [11–15]. The second category encompasses methods such as ligation-independent cloning (LIC), Gibson assembly, and seamless ligation cloning extract (SLiCE) [16–20]. While both categories are widely used in constructing DNA libraries, LIC or Gibson Assembly rely on multi-enzyme reactions, which can be relatively costly due to the need for multiple purified enzymes. In contrast, as previously stated, SLiCE utilizes the natural homologous recombination capabilities of E. coli cell lysates, offering a more economical alternative by using readily available laboratory strains. However, despite these advantages, there have been no reports of SLiCE being applied to the construction of DNA libraries. In this study, we present RecombiCraft, a novel and budget-friendly method to construct DNA libraries in E. coli by SLiCE, followed by a liquid culture that amplifies the libraries and ensure minimal sequence bias. Material and methods Backbone and library insert synthesis The library backbone was created by PCR amplification. The reaction contains 300 μM dNTP, 300 nM each of forward/reverse primer (S1 Table), 0.5 U KAPA HiFi DNA polymerase (07958889001, Roche Diagnostics), 1x KAPA HiFi buffer, and 1 ng template library DNA [21] in a total reaction volume of 20 μL using T100 Thermal Cycler (BIO-RAD). The PCR amplification cycle was as follows: Backbone synthesis 95°C for 3 min; 30 cycles of 98°C for 20 sec, 65°C for 15 sec, 72°C for 2 min; 72°C for 1 min for final extension, Insert synthesis 95°C for 3 min; 30 cycles of 98°C for 20 sec, 65°C for 15 sec, 72°C for 30 sec; 72°C for 1 min for final extension. PCR product was treated with 40U Dpn I for 1 hour and was purified by QIAquick PCR Purification Kit (QIAGEN). The purified DNA was quantified by Qubit dsDNA BR kit (Invitrogen). SLiCE reaction The purified backbone and library inset were assembled by SLiCE. The reaction contains 1x SLiCE buffer, 1uL SLiCE extract, and 100 ng of DNA (backbone-to-insert ratio was 1:10) in a total reaction volume of 10 uL. The reaction mixture was incubated at 37°C for 1 hour followed by purification using QIAquick PCR Purification Kit (QIAGEN). The purified DNA was quantified by Qubit dsDNA BR kit (Invitrogen). Electroporation Assembled library DNA was introduced to NEB® 10-beta Competent E. coli (C3020K, NEB) by using MicroPulser Electroporator (BIORAD). Before electroporation, 50 uL electro-competent cells were aliquoted in a microcentrifuge tube and placed on ice for 10 min, and then 100 ng of SLiCE product was added. Competent cells were transferred to 1mm electroporation cuvette (ThermoFisher), and electroporation was done with a preinstalled EC1 program by following the manufacturer’s protocol followed by preincubation at 37°C for 1 hour in 950 uL Stable Outgrowth Medium. Bacteria culture and library DNA extraction Preincubated cells were cultured at 37°C for the scheduled time in 50 mL LB media with 100 ug/mL Ampicillin. Bacteria were harvested by centrifuge, and library DNA was extracted by ZymoPURE II Plasmid Midiprep kit (Zymo research). For CFU measurement and control sample preparation for next-generation sequence analysis, preincubated cells were plated on LB agar plate with 100 ug/mL, and incubated at 37°C overnight. Next-generation sequencing The sample for next-generation sequencing (Illumina MiSeq) were prepared by PCR amplification using a primer pair (S1 Table) with a sequencing index for the sequencing library amplification. A fluorometric method (Qubit) was used to quantify the dsDNA PCR products before the submission. All the samples were normalized to the same concentration and agarose gel electrophoresis was used to confirm the product size. Sequencing was performed at the MSU Genomics Core facility using MiSeq Reagent Kit v3 for 250 bp paired-end (PE) reads. The generated FASTQ format file was extracted, processed and clustered by sequence similarity using our custom software, ScaffoldSeq5. Result SLiCE-based DNA library construction The SLiCE reaction is a cost-effective and efficient cloning method using bacterial lysates [19, 22]. By designing homologous sequences at both ends of the backbone and insert, it is possible to obtain the desired plasmid through homologous recombination. Fig 1 shows a schematic diagram of library DNA construction applying this technology. Briefly: 1) Homologous Sequences: The backbone and library insert have homologous sequences at both ends; 2) Circularization: These sequences are circularized using the SLiCE reaction; 3) Introduction into E. coli: The circularized DNA is introduced into E. coli cells via electroporation; 4) Growth in Liquid Culture: The E. coli cells containing the library DNA are grown in liquid culture after preincubation; 5) library DNA Extraction: Finally, the amplified library DNA can be extracted using a standard plasmid DNA extraction method. Schematic diagram of library DNA construction. Vector and library insert are prepared by PCR followed by purification. The library assembled by SLiCE is introduced to E.coli by electroporation and amplified through liquid culture. This image was created with BioRender.com. Optimization and characterization of SLiCE library construction It has been shown that the efficiency of SLiCE cloning depends on the length of the terminal homologous sequences. We improved library cloning by creating different-length homologous sequences and comparing their cloning efficiency. To minimize PCR bias during backbone and library insert amplification, KAPA HiFi DNA Polymerase was used for PCR amplification [23]. A combination of approximately 50 bases (57 bp on the 5’ side and 52 bp on the 3’ side) showed the highest efficiency (Fig 2). This trend aligns with the report by Zhang et al [19]. While liquid culture of E. coli is desirable for efficient DNA extraction, concerns arise about differences in clone growth rates affecting library uniformity [24, 25]. To address this, we investigated bias due to liquid culture using next-generation sequencing (NGS). We prepared 20 different monobody sequences with variable binding loop regions [21]. Monobodies are synthetic binding proteins consisting of fibronectin type III domain (FN3) [26, 27]. After introducing a plasmid DNA solution containing equal numbers of molecules of 20 monobody sequences into electrocompetent cells, we cultured them in an antibiotic-supplemented LB medium. Library DNA was extracted at various time points (2H, 4H, 8H, 12H, and 16H) and analyzed by NGS. Comparing cells cultured on LB agar plate as a control, we observed no significant variance change from 2 to 8 hours. However, a significant increase in variance occurred after 12 hours (Fig 2B). Based on these results, we decided to set the culture time for library construction to 8 hours. Optimization and verification of DNA library construction. (A) Optimization of the sequence length for homologous recombination. An overlap of approximately 30 to 70 bases was designed for homologous recombination, and the efficiency of the SLiCE reaction was compared (n = 2). (B) Evaluation of bacteria growth bias due to liquid culture time. DNA uniformly containing 20 types of plasmids randomly selected from the Monobody library was introduced into E. coli by electroporation, and the growth bias of each plasmid-retaining strain at each culture time was analyzed by NGS. Assessment of library DNA generated by optimized construction method The monobody library was designed based on a hydrophilic variant of human fibronectin, which improves biodistribution properties, making it well-suited for downstream applications in molecular imaging and therapeutics. This hydrophilic monobody library included diverse amino acid sequences in three solvent-exposed binding loops, akin to antibody CDR-H1/2/3, while conserving amino acids in the framework positions. This process aimed to enhance the efficiency and accuracy of library generation. The monobody library consisted of approximately 300 bases in length, and amplification was performed using primers that amplify a region of approximately 400 bases containing the monobody library. Amplification of an approximately 400 base insert was confirmed, and no backbone-derived amplicon (89bp) or any off-target products were detected (Fig 3A). This suggested that the presence of backbone and off-target products was below the detection limit of PCR. This absence of unwanted sequences ensures the purity and specificity of the library DNA. To further validate the efficiency of our library construction, we performed linearization using restriction enzymes. This step confirmed an increase in the overall size of the library DNA. The larger size indicated the monobody library DNA was indeed efficiently generated (Fig 3B). This optimized construction method confirmed the absence of unwanted sequences and validated the structural integrity and diversity of the monobody library, making it a robust tool for various biomedical applications. Library fragment verification by PCR. (A) A monobody library was created utilizing this method, and the length of the inserted sequence was confirmed using a primer that amplifies the insert. (B) Size verification by linearizing with Restriction Enzyme. The library DNA and backbone plasmid were digested to BamHI restriction enzyme to linearize the constructs for size verification by gel electrophoresis. Discussion Establishing a DNA library constitutes a critical procedure in biotechnology, genetic engineering, and basic research. This process involves extracting or synthesizing DNA fragments encoding for a collection of protein variants, then inserting these fragments into vectors. The DNA library is then introduced into host cells (often bacteria or yeast) to express the encoded protein variants, allowing for functional screens, enrichment, or selection of high performing protein variants. SLiCE cloning has emerged as a versatile and effective method for molecular cloning, offering a more flexible alternative to traditional methods. Unlike conventional cloning techniques dependent on restriction enzymes, which require matching restriction sites and often involve laborious procedures–SLiCE cloning is not constrained by these requirements [28]. Traditional approaches often come with limitations like inefficient ligation and incomplete digestion, which pose challenges in constructing large DNA libraries and can lead to time-consuming efforts [1]. Adopting liquid culture also reduces the cost and time required for library DNA extraction (Fig 4). Comparison of various library cloning methods. A comparison of the steps, time, and costs involved in RecombiCraft and two other commonly used methods for constructing a DNA library. One significant advantage of SLiCE is its ability to accommodate homologous recombination even when extra sequences exist at the ends of backbone and insert (S1 Fig). This feature significantly enhances the flexibility of experimental designs, outperforming both traditional cloning techniques and modern methods, such as Gibson Assembly Unlike these methods, SLiCE cloning allows for the integration of DNA fragments into backbones without the need for precise end sequence matching or further modifications, thus improving adaptability and simplifying the cloning process [19, 22]. An essential element of SLiCE cloning is the homology length and polymerase selection involved in the process. Our results indicate that homologous regions of approximately 50 bases at both the 3’ and 5’ ends are efficient for library cloning, corroborated in studies by Zhang et al and Messerschmidt [19, 28]. While some exceptions have been reported, increasing the insert ratio generally correlates with higher cloning efficiency [19, 29]. The choice of polymerase plays a significant role in library cloning, as it can introduce bias in sequences amplified through PCR. Some polymerases falter when amplifying templates with high GC or AT content due to coverage bias. Previous studies demonstrated that the high-fidelity Kapa HiFi polymerase can amplify regions with AT-rich and GC-rich content, whereas other polymerases, like Phusion, may fail generally. However, Kapa HiFi polymerase does have a tendency to introduce errors in these challenging regions [30, 31]. Factors such as sequence composition, PCR reaction temperatures, and sequence length are also crucial considerations. The polymerase’s origin may dictate its thermal stability during PCR [32, 33], and the accurate amplification of longer sequences may hinge on the enzyme’s proofreading capability and processivity [34]. In recent years, it has been reported that liquid culture has superior library uniformity compared to plating or semi-solid culture [35], however, our experimental observations also pinpointed liquid culture as a potential source of bias in library generation. Variation in plasmid size, copy number, and specific sequence repeats can exert different metabolic demands on the host bacteria. Consequently, E.coli cells harboring certain plasmids may exhibit varied growth speed rates [36]. To address this concern, we assessed the growth bias attributable to incubation duration, revealing that the library uniformity could be compromised beyond 12 hours. Thus, we advocate for an 8-hour incubation period as the standard for this protocol. Adjusting incubation periods can be fine-tuned based on the specific goals of the experiment. Other research supports this, indicating that controlling growth bias is possible by carefully optimizing conditions like the composition of the growth medium and the levels of antibiotics used [24]. Verification of DNA libraries constructed via this method confirmed the successful insertion of only the intended library fragments and uniform linearized library assembly. While this example utilizes a monobody library, the technology is amenable to expansion for other library screening applications that involve cloning, including phage display. Additionally, the essential materials for this process are readily available in most molecular biology laboratories, offering a considerable cost advantage over commercial library construction kits. In conclusion, our study introduces a novel DNA library construction methodology utilizing SLiCE, which we have named RecombiCraft. This approach facilitates the acquisition of sufficient DNA quantities for downstream applications by optimizing the liquid incubation period. When combined with existing techniques, this SLiCE-based method holds potential for a diverse range of applications. Supporting information The list of primers used in this study. (TIF) The design flexibility of SLiCE cloning. (TIF) (PDF) 29 Aug 2024 PONE-D-24-25871RecombiCraft Library construction: A novel method for DNA Library cloning and expansion using non-enzymatic single-step DNA recombination and liquid culturePLOS ONE Dear Dr. Harada, Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process. Please submit your revised manuscript by Oct 12 2024 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org. When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file. Please include the following items when submitting your revised manuscript:A rebuttal letter that responds to each point raised by the academic editor and reviewer(s). You should upload this letter as a separate file labeled 'Response to Reviewers'.A marked-up copy of your manuscript that highlights changes made to the original version. You should upload this as a separate file labeled 'Revised Manuscript with Track Changes'.An unmarked version of your revised paper without tracked changes. You should upload this as a separate file labeled 'Manuscript'. A rebuttal letter that responds to each point raised by the academic editor and reviewer(s). You should upload this letter as a separate file labeled 'Response to Reviewers'. A rebuttal letter that responds to each point raised by the academic editor and reviewer(s). You should upload this letter as a separate file labeled 'Response to Reviewers'. A marked-up copy of your manuscript that highlights changes made to the original version. You should upload this as a separate file labeled 'Revised Manuscript with Track Changes'. A marked-up copy of your manuscript that highlights changes made to the original version. You should upload this as a separate file labeled 'Revised Manuscript with Track Changes'. An unmarked version of your revised paper without tracked changes. You should upload this as a separate file labeled 'Manuscript'. An unmarked version of your revised paper without tracked changes. You should upload this as a separate file labeled 'Manuscript'. If you would like to make changes to your financial disclosure, please include your updated statement in your cover letter. Guidelines for resubmitting your figure files are available below the reviewer comments at the end of this letter. If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: https://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols. Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-email&utm_source=authorletters&utm_campaign=protocols. We look forward to receiving your revised manuscript. Kind regards, Md Rajib Sharker, Ph.D. Academic Editor PLOS ONE Journal Requirements: 1. Please ensure that your manuscript meets PLOS ONE's style requirements, including those for file naming. The PLOS ONE style templates can be found at https://journals.plos.org/plosone/s/file?id=wjVg/PLOSOne_formatting_sample_main_body.pdf and https://journals.plos.org/plosone/s/file?id=ba62/PLOSOne_formatting_sample_title_authors_affiliations.pdf 2. Thank you for stating the following financial disclosure: This project received financial support from two sources: the Elsa U. Pardee Foundation, which focuses on cancer research and treatment funding, and the Michigan Translational Research and Commercialization (MTRAC) program, which provides early-stage funding to promote the commercialization of innovative technologies. Please state what role the funders took in the study. If the funders had no role, please state: ""The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript."" If this statement is not correct you must amend it as needed. Please include this amended Role of Funder statement in your cover letter; we will change the online submission form on your behalf. 3. PLOS ONE now requires that authors provide the original uncropped and unadjusted images underlying all blot or gel results reported in a submission’s figures or Supporting Information files. This policy and the journal’s other requirements for blot/gel reporting and figure preparation are described in detail at https://journals.plos.org/plosone/s/figures#loc-blot-and-gel-reporting-requirements and https://journals.plos.org/plosone/s/figures#loc-preparing-figures-from-image-files. When you submit your revised manuscript, please ensure that your figures adhere fully to these guidelines and provide the original underlying images for all blot or gel data reported in your submission. See the following link for instructions on providing the original image data: https://journals.plos.org/plosone/s/figures#loc-original-images-for-blots-and-gels. In your cover letter, please note whether your blot/gel image data are in Supporting Information or posted at a public data repository, provide the repository URL if relevant, and provide specific details as to which raw blot/gel images, if any, are not available. Email us at plosone@plos.org if you have any questions. 4. Please include captions for your Supporting Information files at the end of your manuscript, and update any in-text citations to match accordingly. Please see our Supporting Information guidelines for more information: http://journals.plos.org/plosone/s/supporting-information. Additional Editor Comments (if provided): The manuscript is well-organized and clearly written, presenting a study objective that is both relevant and valuable for publication. However, I strongly encourage the authors to address several critical issues within the manuscript. These concerns need to be thoroughly addressed to enhance the quality and rigor of the study. Therefore, I recommend that the manuscript undergo significant revisions before it can be considered for publication. [Note: HTML markup is below. Please do not edit.] Reviewers' comments: Reviewer's Responses to Questions Comments to the Author 1. Is the manuscript technically sound, and do the data support the conclusions? The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented. Reviewer #1: Yes Reviewer #2: Yes ********** 2. Has the statistical analysis been performed appropriately and rigorously? Reviewer #1: Yes Reviewer #2: Yes ********** 3. Have the authors made all data underlying the findings in their manuscript fully available? The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified. Reviewer #1: Yes Reviewer #2: Yes ********** 4. Is the manuscript presented in an intelligible fashion and written in standard English? PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here. Reviewer #1: Yes Reviewer #2: Yes ********** 5. Review Comments to the Author Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters) Reviewer #1: In this study, the author presents a novel, rapid, and cost-effective method for constructing DNA libraries in E. coli. RecombiCraft combines seamless ligation cloning extract (SLiCE) with liquid culture amplification to minimize sequence biases. The method employs high-fidelity polymerase for the PCR synthesis of library backbones and inserts, and utilizes SLiCE for the assembly of DNA fragments, which are then introduced into E. coli via electroporation. RecombiCraft proves to be an economical and efficient tool, maintaining library uniformity and significantly shortening the library generation period, thus making it a valuable asset for genetic research and biotechnological applications. The manuscript is well-organized and written, and the study's objective is worthy of publication. However, the reviewer strongly encourages the authors to address the following issues. Major amendments are required before the manuscript can be published. Constructive comments for revision are as follows: Major concern 1. The author introduces RecombiCraft as an "innovative, rapid, and cost-efficient method" but doesn't provide enough specific details on what makes it unique compared to existing methods. Adding data or results could strengthen the claim. Query 2: The manuscript would be significantly strengthened if you will do comet assay to check the DNA integrity after exposure and recovery of crude oil. Query 3: The quality of some figures is not adequate for publication. Query 4: In discussion section, rephrased some sentences for better readability and coherence. Query 5: Made the comparison between SLiCE cloning and traditional methods clearer and more concise. Minor comments: Line 27: The phrase "significantly shorter library generation period" is vague. Providing specific time comparisons with other methods would make this claim more impactful. Line 102: Library DNA" should either both be capitalized and not, depending on whether it's a proper noun. It might be better as "library DNA". Please check it throughout the manuscript. Line 116-117: The sentence "To optimize library cloning, we created homologous sequences of varying lengths and compared their cloning efficiency." could be simplified or rephrased for clarity. Line 149-151: Please omit correct the sentence in following ways. The monobody library was designed based on a hydrophilic variant of human fibronectin, which improves biodistribution properties, making it well-suited for downstream applications in molecular imaging and therapeutics days post fertilization as you mentioned it before. Line 152: The term "throughout" is omitted, which makes the sentence slightly redundant. Correct the sentence in following ways. This hydrophilic monobody library included diverse amino acid sequences in three solvent-exposed binding loops, akin to antibody CDR-H1/2/3, while conserving amino acids in the framework positions. Line 159: The phrase "at least backbone" is confusing and seems incorrect. Line 164-165: he phrase "not only... but also" suggests two parallel ideas, but the way it's phrased here makes it slightly unclear. Correct the sentence in following ways. This optimized construction method confirmed the absence of unwanted sequences and validated the structural integrity and diversity of the monobody library. Line 172: Used "host cells" instead of "suitable cells" for clarity and consistency. Line 192: Replaced "however" with a semicolon to improve readability and flow. Line 198: Used "may" instead of "might" for a more formal tone and added "generally" to clarify that the correlation is not absolute. Line 220-223: Changed "named RecombiCraft" to "which we have named RecombiCraft" for clarity. Changed "enables acquisition of sufficient DNA quantities" to "facilitates the acquisition of sufficient DNA quantities" for smoother readability. Changed "fine-tuning" to "optimizing" for a more formal tone and clearer meaning. Reviewer #2: General comments of the manuscript: The manuscript entitled, “RecombiCraft Library construction: A novel method for DNA Library cloning and expansion using non-enzymatic single-step DNA recombination and liquid culture”, is completely novel in biotechnology for sustainable development and wellbeing of the shorter library generation period. From the reviewer observation this research manuscript can be accepted with minor corrections in the esteemed journal, “PlosOne”. The following correction is given below: The first figure requires high resolution since it seem a fuzzy like image to the reviewer. 1) Introduction: Accepted 2) Materials and methods: Accepted 3) Results: Accepted 4) Discussion: Accepted 5) Conclusion: Accepted ********** 6. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy. Reviewer #1: No Reviewer #2: No ********** [NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.] While revising your submission, please upload your figure files to the Preflight Analysis and Conversion Engine (PACE) digital diagnostic tool, https://pacev2.apexcovantage.com/. PACE helps ensure that figures meet PLOS requirements. To use PACE, you must first register as a user. Registration is free. Then, login and navigate to the UPLOAD tab, where you will find detailed instructions on how to use the tool. If you encounter any issues or have any questions when using PACE, please email PLOS at figures@plos.org. Please note that Supporting Information files do not need this step. 30 Sep 2024 We appreciate the positive response from the editor/reviewer. The manuscript has been edited according to the suggestions. Point-by-point response is as follows: Reviewer 1 Major concern 1. The author introduces RecombiCraft as an "innovative, rapid, and cost-efficient method" but doesn't provide enough specific details on what makes it unique compared to existing methods. Adding data or results could strengthen the claim. >Thank you for your comment. We added the sentence to emphasize uniqueness in the abstract. Figure 4 also explains the difference between other traditional methods. Query 2: The manuscript would be significantly strengthened if you will do comet assay to check the DNA integrity after exposure and recovery of crude oil. >Thank you for your comment. This method proposes DNA library preparation, we think that figure 3 shows purity good enough for downstream applications. Query 3: The quality of some figures is not adequate for publication. >We have separately uploaded high-resolution images as figures. Query 4: In discussion section, rephrased some sentences for better readability and coherence. >We reassessed these sections and have modified the text to improve readability. Query 5: Made the comparison between SLiCE cloning and traditional methods clearer and more concise. >We have included additional text within the Discussion section to emphasize the superior aspects of this method. Minor comments: Line 27: The phrase "significantly shorter library generation period" is vague. Providing specific time comparisons with other methods would make this claim more impactful. >We have now specified the minimum time to prepare DNA library in the Abstract. Line 102: Library DNA" should either both be capitalized and not, depending on whether it's a proper noun. It might be better as "library DNA". Please check it throughout the manuscript. > All spellings except the first word have been unified to "library." Line 116-117: The sentence "To optimize library cloning, we created homologous sequences of varying lengths and compared their cloning efficiency." could be simplified or rephrased for clarity. >This sentence has been rephrased: “We improved library cloning by creating different-length homologous sequences and comparing their cloning efficiency.“ Line 149-151: Please omit correct the sentence in following ways. The monobody library was designed based on a hydrophilic variant of human fibronectin, which improves biodistribution properties, making it well-suited for downstream applications in molecular imaging and therapeutics days post fertilization as you mentioned it before. > The statement has been corrected as indicated. Line 152: The term "throughout" is omitted, which makes the sentence slightly redundant. Correct the sentence in following ways. This hydrophilic monobody library included diverse amino acid sequences in three solvent-exposed binding loops, akin to antibody CDR-H1/2/3, while conserving amino acids in the framework positions. > The statement has been corrected as indicated. Line 159: The phrase "at least backbone" is confusing and seems incorrect. >”at least” was removed to correct this sentence. Line 164-165: he phrase "not only... but also" suggests two parallel ideas, but the way it's phrased here makes it slightly unclear. Correct the sentence in following ways. This optimized construction method confirmed the absence of unwanted sequences and validated the structural integrity and diversity of the monobody library. > The statement has been corrected as indicated. Line 172: Used "host cells" instead of "suitable cells" for clarity and consistency. > The statement has been corrected as indicated. Line 192: Replaced "however" with a semicolon to improve readability and flow. > The statement has been corrected as indicated. Line 198: Used "may" instead of "might" for a more formal tone and added "generally" to clarify that the correlation is not absolute. > The statement has been corrected as indicated. Line 220-223: Changed "named RecombiCraft" to "which we have named RecombiCraft" for clarity. Changed "enables acquisition of sufficient DNA quantities" to "facilitates the acquisition of sufficient DNA quantities" for smoother readability. Changed "fine-tuning" to "optimizing" for a more formal tone and clearer meaning. > The statement has been corrected as indicated. Reviewer 2 Thank you very much for the positive comments. We have uploaded a higher-resolution image tiff file. Submitted filename: Responses.docx 2 Oct 2024 RecombiCraft library construction: A novel method for DNA library cloning and expansion using non-enzymatic single-step DNA recombination and liquid culture PONE-D-24-25871R1 Dear Dr. Harada We’re pleased to inform you that your manuscript has been judged scientifically suitable for publication and will be formally accepted for publication once it meets all outstanding technical requirements. Within one week, you’ll receive an e-mail detailing the required amendments. When these have been addressed, you’ll receive a formal acceptance letter and your manuscript will be scheduled for publication. An invoice will be generated when your article is formally accepted. Please note, if your institution has a publishing partnership with PLOS and your article meets the relevant criteria, all or part of your publication costs will be covered. Please make sure your user information is up-to-date by logging into Editorial Manager at Editorial Manager® and clicking the ‘Update My Information' link at the top of the page. If you have any questions relating to publication charges, please contact our Author Billing department directly at authorbilling@plos.org. If your institution or institutions have a press office, please notify them about your upcoming paper to help maximize its impact. If they’ll be preparing press materials, please inform our press team as soon as possible -- no later than 48 hours after receiving the formal acceptance. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org. Kind regards, Md Rajib Sharker, Ph.D. Academic Editor PLOS ONE Additional Editor Comments (optional): The authors did adequately address all the queries raised by Reviewer in their revised manuscript. The paper can now be considered for publication 16 Oct 2024 PONE-D-24-25871R1 PLOS ONE Dear Dr. Harada, I'm pleased to inform you that your manuscript has been deemed suitable for publication in PLOS ONE. Congratulations! Your manuscript is now being handed over to our production team. At this stage, our production department will prepare your paper for publication. This includes ensuring the following: * All references, tables, and figures are properly cited * All relevant supporting information is included in the manuscript submission, * There are no issues that prevent the paper from being properly typeset If revisions are needed, the production department will contact you directly to resolve them. If no revisions are needed, you will receive an email when the publication date has been set. At this time, we do not offer pre-publication proofs to authors during production of the accepted work. Please keep in mind that we are working through a large volume of accepted articles, so please give us a few weeks to review your paper and let you know the next and final steps. Lastly, if your institution or institutions have a press office, please let them know about your upcoming paper now to help maximize its impact. If they'll be preparing press materials, please inform our press team within the next 48 hours. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org. If we can help with anything else, please email us at customercare@plos.org. Thank you for submitting your work to PLOS ONE and supporting open access. Kind regards, PLOS ONE Editorial Office Staff on behalf of Dr. Md Rajib Sharker Academic Editor PLOS ONE