Gellan gum-based granular gels as suspension media for biofabrication Authors: Andrew McCormack, Laura M. Porcza, Nicholas R. Leslie, Ferry P. W. Melchels, Pradeep Kumar, Pradeep Kumar, Pradeep Kumar Published: 2024 ABSTRACT Engineering 3D tissue-like constructs for applications such as regenerative medicine remains a major challenge in biomedical research. Recently, self-healing, viscoplastic fluids have been introduced as suspension media to allow lower viscosity, water-rich bioinks to be printed within them for the fabrication of more biomimetic structures. Here, we present gellan gum granular gels produced through the application of shear during gelation, as a candidate suspension medium. We demonstrate that these granular gels exhibit viscoplasticity over a wide range of temperatures, permitting their use for 3D bioprinting of filaments and droplets at low (4°C) as well as physiological temperatures. These granular gels exhibit very low yield stresses (down to 0.4 Pa) which facilitated printing at print speeds up to 60 mm.s-1. Furthermore, we demonstrate the printing of cell-laden droplets maintained over 7 days to show the potential for multiple days of cell culture, as well as the fabrication of hydrogel features within a crosslinkable version of the suspension medium containing granular gellan gum and gelatine-methacryloyl. The combination of ease of preparation, high printing speed, wide temperature tolerance, and crosslinkability makes this gellan gum sheared through cooling-induced gelation an attractive candidate for suspended biofabrication. 1. Introduction Granular hydrogels are emerging as a versatile platform for engineering tissue constructs in the biofabrication field. They offer an alternative microarchitecture for 3D cell culture compared to the conventional bulk polymer network hydrogels used ubiquitously in the field. Where the mechanical properties of bulk hydrogels arise solely from the cross-linking of polymer chains, the properties of granular hydrogels depend, to a large extent, on the degree of jamming of microparticles in their swollen state [1]. Around the jamming/unjamming transition of these microparticles, granular hydrogels exhibit unique physical properties such as a resistance to applied stress, shear-thinning and self-healing [1–3], making them suitable candidate materials for biofabrication applications. Specifically, these granular gels have recently been explored for 3D bioprinting, where they act as a supportive gel bath into which bioinks can be extruded [4–6]. The use of suspension media with extrusion 3D printers is an emerging fabrication strategy that has been transformative to the 3D bioprinting field, primarily as it has removed the need to print layers sequentially, one on top of the other. With conventional layer-by-layer extrusion printing, optimising the rheological properties of bioinks to ensure a high degree of printability without loss of biological function is critical to the biofabrication process. Bioinks that provide a more biomimetic environment for cell encapsulation typically, have a high water-content and low viscosity [7, 8]. Such properties are detrimental to their printability by permitting rapid fluidisation of these inks post-printing, and thus collapse of printed structures [7]. Extruding low viscosity inks within the volume of a suspension media ensures support is given to the printed structure prior to secondary ink crosslinking mechanisms, while also facilitating printing both irregular and complex geometrical structures. Notably, the main characteristics of suspension media that permit their ability to support extruded bioinks are related to their rheological properties [6]. These media are yield stress fluids, exhibiting a transition from an elastic solid to a viscoplastic fluid as their yield stress is overcome. As a result, the suspension media will fluidise through the action of the moving printing nozzle and can be easily displaced to accommodate the deposition of extruded ink [9]. Subsequently, these suspension media require a short recovery time to ensure complete immobilisation of the bioink following removal of the applied stress generated by the movement of the nozzle and the forces exerted by material deposition [9]. While the application of suspension media in biofabrication increases, the exploration of materials suitable for use as a suspension media is required to fully realise the value of this printing strategy for engineering of human tissues. The temperatures that a suspension media can be employed at are critical to their performance, often dictating the temperature range of the extruder nozzle [10], or maintaining the yield stress of the suspension media [4, 11]. We, therefore, looked at the development of suspension media that can be used over a wide range of temperatures. Furthermore, we hypothesised that using low concentrations of polymer in a granular gel would lead to a low yield stress, which may allow higher printing speeds to be obtained. In this work we explored the preparation of granular gels using gellan gum and their application as suspension media in various biofabrication applications. Gellan gum is a biopolymer with a tetra-saccharide repeating unit consisting of glucose, glucuronic acid and rhamnose, and is already clinically used in the ophthalmic field in eye drop solutions [12]. The mechanism for the sol-gel transition of gellan gum involves conformational transition of the polymer chains in solution from a disordered random coil state to an ordered double helix state, followed by helix-helix aggregation [13]. In the presence of monovalent or divalent cations, the effect of electrostatic repulsions between helices is reduced, via the cations electrically shielding carboxylic groups on neighbouring polymer chains [14]. We identified gellan gum as a potential biopolymer for use as a suspension media, due to the polymer solutions exhibiting thermal gelation (~ 42–45°C) and melting (~ 70–80°C) temperatures much greater than physiological temperatures, thus preventing liquification of the polymer granules under cell culture of 37°C. Using gellan gum, we developed a rapid and reliable method for creating granular gel suspension media using polymer concentrations between 0.1–0.5% w/v, through applying shear as the gellan gum goes through its sol-gel transition upon cooling and in the presence of monovalent cations. This is a one-step method following the dissolution of the polymer, in contrast to other methodologies for producing granular gels which involve complete cooling-induced gelation followed by breaking up the macrogel into microgels, centrifugation and washing steps to produce a jammed granule network [4, 15]. Jammed granule networks exist due to a high granule-to-interstitial volume ratio, causing the gel to behave solid-like in the absence of an applied stress [1]. These gellan gum suspension media were used to demonstrate the printing of filaments and cell-laden droplets. We further hypothesised that by combining these gellan gum granular suspension media with gelatine methacryloyl (gelMA), a medium would be obtained that retained both the suspension properties of the granular gel as well as the ability to photo-cure the resulting structures for long-term stability. This technique may allow the suspension medium to double as bulk matrix and allow for rapid fabrication of a larger tissue construct. 2. Materials and methods 2.1 Granular gel preparation Known concentration of low acyl gellan gum (Alfa Aesar) was dissolved in phosphate buffered saline, PBS (Fisher Scientific). Following dissolution, the hot polymer was cooled through its sol-gel temperature (20 mins) under constant shearing of 600 RPM using an overhead stirrer (Caframo™ Petite Overhead Stirrer, Fisher Scientific). Prior to bioprinting granular gels were irradiated with a UV light source in a laminar biosafety cabinet for 30 min. 2.2 Photo-curable suspension media Known concentration of gelMA (either 5 or 10% (w/v)) and 0.1% (w/v) lithium phenyl-2,4,6-trimethylbenzoylphosphinate (LAP, Sigma Aldrich) were added to a gellan gum granular gel (0.3% w/v) and dissolved at 37°C overnight. The resulting solution was then centrifuged for 2 min at 1000 RPM to remove air bubbles and stored at 4°C. Suspension media formulations were incubated at 37°C prior to use. 2.3 Polymer solutions used for biofabrication 3D printing was carried out using either poloxamer- or gelatine-methacryloyl (gelMA)–based solutions. Poloxamer solution was prepared by dissolving 30% (w/v) poloxamer 407 (Fisher Scientific) in deionised water at 4°C. In some instances, blue food dye was added to aid visualisation of printed filaments. GelMA-based solutions for droplet printing were prepared by dissolving 10% (w/v) gelMA in PBS with 0.05% (w/v) LAP photoinitiator. These solutions were heated to 50°C and then passed through a Whatman Puradisc 25 mm PES syringe filter, with a pore size of 0.2 μm prior to mixing in a cellular component. GelMA was prepared by reaction of type A gelatine (300 Bloom, Sigma Aldrich) derived from porcine skin tissue with methacrylic anhydride (Sigma Aldrich) for 1 h at 50°C. The experimental procedure was based on a previously described protocol developed by Van den Bulcke et al. [16]. Briefly, methacrylic anhydride was added dropwise to a 10% (w/v) solution of gelatine in phosphate-buffered saline (Fisher BioReagents), under constant stirring. Methacrylic anhydride was added at a ratio of either 0.02 g or 0.6 g per 1 g of gelatine. Before the addition of anhydride, the pH of the gelatine solution was adjusted to pH 8, with the addition of 5M NaOH solution. Following the reaction, centrifugation and dialysis (cellulose membrane, cut-off 12 kDa) against distilled water were performed to remove methacrylic acid and anhydride. The gelMA macromonomer solution was neutralised and then lyophilised and stored at -20°C until use. Validation of gelMA synthesis was carried out using proton-nuclear magnetic resonance spectroscopy (1H-NMR, Bruker AVIII 300 MHz). GelMA solutions used for 3D printing of helix structures (FITC-gelMA) were prepared by dissolving 10% (w/v) fluorescein isothiocyanate (FITC) labelled gelMA in PBS with 0.1% (w/v) LAP photoinitiator. 2.4 Imaging and analysis Granular gels were visualised by loading 200 μL onto a microscope slide mounted with an additional slide and imaged using an Eclipse TS100 inverted microscope (Nikon) equipped with a 10 X objective. Due to printed filaments requiring lower magnification for imaging, these structures were imaged using a digital camera (iPhone XS). All image processing was done using ImageJ. For droplet imaging, droplet surface area and circularity were calculated by tracing the droplet perimeter using the wand tool, then measuring using the Measure command. 2.5 Rheometry Rheological analysis was performed using a Kinexus rheometer (Malvern Instruments, Worcestershire, UK) using a cone and plate geometry, with a gap height of 0.14 mm. Yield stress analysis was performed by conducting amplitude sweeps, on oscillatory mode with a frequency of 1 Hz. Thixotropic analysis of granular gels was conducted by carrying out a custom-built isothermal, stress-controlled, single frequency oscillation test. The test was carried out for 4.5 min, where the shear stress was alternated between low and high values–below and above the yield stress of the sample. The time at each stress was fixed at 30 s. Samples were equilibrated at either 20 or 37°C for 5 min in the rheometer prior to testing. All measurements were performed in triplicate, except for the yield stress measurements at 37°C where n = 2. 2.6 Mass flow rate determination 30% (w/v) poloxamer ink was loaded into a print cartridge and equilibrated at 30°C for 10 min prior to printing. The combined mass of ink, cartridge and nozzle was then measured pre- and post-extrusion. Mass flow rate (m˙) was then determined using the equation m˙=Q˙*ρ, where Q˙ is the volumetric flow rate and ρ is the density of the ink. 2.7 Cell culture Transduction of tumour cell lines, namely CFPAC-1 (pancreatic tumour cell line) and U87-MG (glioma cell line), with green fluorescent protein (GFP) and red fluorescent protein (RFP) respectively, and subsequent cloning of these cells was performed to obtain fluorescent cultures. CFPAC-1 cells were cultured in proliferation medium, Iscove’s modified Dulbecco’s medium 12440–053 (IMDM) (Gibco), supplemented with 10% foetal bovine serum F7524 (FBS) (Sigma/Merck, UK) and 1% Glutamax 100X (Gibco, UK), while U87-MG cells were cultured in MEM non-essential amino acid solution M7145 (Sigma/Merck, UK) supplemented with 10% FBS, 1mM sodium pyruvate (Gibco, UK), 1% Glutamax 100X and 1% MEM non-essential amino acid solution 100X. Standard culturing conditions of 37°C and 5% CO2 were used, and cells were passaged when the colonies reached 80% confluency (typically, every 2–3 days). 2.8 Fabrication of 3D printed structures For printing of filament structures on tissue culture plates and within gellan gum granular gels, bioink cartridges were loaded with poloxamer ink, attached to a conical nozzle with an internal diameter of 210 μm and loaded in a Cellink BioX 3D bioprinter (Cellink, Sweden). A custom G-code, controlling extrusion speed and pressure was written in order to print filament structures. Droplet-based bioprinting was carried out by replacing the pneumatic printhead on the BioX with an electromagnetic droplet (EMD) printhead equipped with a 300 μm, straight nozzle. Mixing of the cellular component and a gelMA ink was carried out manually using a pipette within the print cartridge followed by 30 s of vortexing the cartridge to ensure homogenous distribution of cells. The print cartridge was then loaded into the EMD printhead. All droplet printing was carried out using a print temperature of 37°C. Following printing, the suspension medium was diluted at a 1:1 ratio with proliferation medium that had been supplemented with 2% antibiotic-antimycotic solution. Printed constructs were then incubated at 37°C in 5% CO2 for a desired amount of time. Printing of helices in photo-curable suspension media was carried out, by loading bioink cartridges with FITC-gelMA ink, attached to a 27 G tapered nozzle. The photo-curable suspension medium was incubated and held at 37°C. The FITC-gelMA ink was incubated at 20°C for 15 min in the Cellink BioX printer prior to printing. Printing of helices was carried out using the printing parameters; pressure = 160 kPa, print speed = 20 mm·min-1. The helices were printed using a custom G-code written in-house. Following printing the entire construct was irradiated with a 405 nm light source (3D Printer UV Resin Light, FGRYB Amazon, UK) for 10 min. 2.9 Mechanical testing Photo-curable suspension media were photo-crosslinked in custom-made, cylindrical Teflon moulds with diameter of 3 mm and thickness of 1.6 mm. GelMA precursor solutions were injected into the Teflon moulds at 37°C. Photo-crosslinking time was fixed at 10 min using a 405 nm light source. Discs were inspected for any air bubbles and those, which contained bubbles were excluded, n = 5 discs were tested for each gelMA concentration. GelMA-only controls were prepared in the same manner, only using LAP-supplemented PBS without gellan gum particles to dissolve gelMA at known concentrations. Compression testing was performed on the hydrogel discs, on a DMA Q800 dynamic thermal mechanical analyser (TA instruments) using a compression clamp set up. The discs were swollen in PBS at room temperature overnight before testing. Strain ramps were performed on the samples, by applying 30% strain·min-1 from 0–90% strain. The Young’s modulus was taken as the slope of the stress-strain curve from 5 to 10% strain. Data was processed in Microsoft Excel and OriginLab OriginPro 2018b. 2.10 Statistical analysis Analysis of numerical datasets was performed using Minitab 18 software (Minitab LLC, State College, PA, USA). Statistical comparisons between two experimental groups were performed using two-tailed Student’s t tests. The threshold for statistical significance was set to p = 0.05. Exact p values are provided in Figures. 3. Results 3.1 Granule production and gel rheological characterisation The simultaneous shearing and cooling of dilute gellan gum solutions in the presence of monovalent ions consistently resulted in suspensions of gel particles that behaved as yield stress fluids. These gels when left undisturbed were found to resist flow, whilst being easily displaced by pipetting or stirring. In contrast, non-sheared control gels were solid, could not be stirred or pipetted, and fractured irreversibly at higher loads. The gel granules were predominantly irregularly shaped with spindle-like protrusions extending from the granule body (Fig 1a–1c). The gels obtained from this shearing methodology exhibited high granule interconnectivity in their undiluted (jammed) state (Fig 1a). Upon dilution, granular gels broke up into smaller clusters (Fig 1b and 1c). Although it was unclear if and when single granules were obtained, it was evident that the granules had dimensions in the tens of microns. Stress amplitude sweeps on a rheometer, conducted at room temperature, revealed that the granular gels behaved as yield stress fluids, where the cross-over point of the storage modulus (G’) and the loss modulus (G”) was used to quantify the yield point. The yield stress depended strongly on gellan gum concentration (Fig 1d) but not on rotational speed of the overhead stirrer (Fig 1e) over the range of impeller speeds investigated. Assessment of gellan gum granular gels. (A-C) Brightfield micrographs of a 0.3% (w/v) gellan gum granular gel. (A) Undiluted gellan gum granular gel. (B-C) Gellan gum granular gels diluted with PBS using various dilution factors. (scale bars: 200 μm). (D-E) Yield stress dependence on the granular gel preparation conditions, where the yield stress was assessed as a function of either gellan gum polymer concentration (D) or the rotational speed of the overhead stirrer (E) n = 3. Gellan gum granular gels continued to exhibit a yield stress when heated to 37°C (Fig 2), however a decrease from 3.4 ± 0.3 (n = 3) to 0.81 ± 0.07 Pa was observed (n = 2). Alternating between high and low stress confirmed reversibility of the solid-liquid transition (Fig 2b and 2d). The increase in incubation temperature of the granular gel was found to cause a slight decrease in the recovery time from 3.42 ± 0.15 s at 20°C to 3.25 ± 0.32 s at 37°C (n = 3), where the recovery time was determined as the time taken for G’ to achieve 80% of its steady-state value [9]. G’ recovery values were highly consistent after each successive high stress phase. The initial G’ value during the first low stress phase differed markedly between each experiment, which is thought to relate to the operation of the rheometer and should not be taken as a fundamental difference in material property between the two temperatures. Rheological analysis of a 0.3% (w/v) gellan gum granular gel performed at either 20°C (A, C) or 37°C (B, D). (A-B) Representative steady shear stress ramp performed for yield stress (σy) determination. (C-D) Representative alternating low and high shear stress, (stress-controlled. single frequency oscillation test) performed to study self-healing behaviour of granular gels (n = 3). 3.2 3D printing in gellan gum suspension media The suitability of the gellan gum granular gels for several bioprinting modalities was assessed, including extrusion printing of filaments and micro-valve bioprinting [17, 18]. Using poloxamer 407 as a model ink, continuous filaments were printed at various nozzle translational speeds using a conical nozzle with an inner diameter of 210 μm, either into gellan gum suspension media (GGSM), or onto a tissue culture polystyrene (TCPS) petri dish in air as a comparison (Fig 3). All prints were made using the same extrusion air pressure of 60 kPa, which resulted in the same mass flow rate of poloxamer ink extruded in either air onto TCPS, or into gellan gum granular gels (8.9 ± 0.4 mg·s-1 vs. 8.6 ± 0.4 mg·s-1, p = 0.551, n = 3). This indicates that the granular gel was not impeding flow of ink from the nozzle. Assessment of filaments printed with a poloxamer ink (30% w/v) onto/into different substrates. (A) (top row) Filaments printed on tissue culture polystyrene petri dish. (bottom row) Filament printed into a 0.3% (w/v) gellan gum suspension medium. (scale bars: 5 mm). (B) Comparison of the effect of nozzle translational speed on the diameter of filaments printed in either gellan gum suspension media or on a tissue culture petri dish. Printing parameters: pressure = 60 kPa, print temperature = 30°C, nozzle = 210 μm conical nozzle (n = 10). Filaments printed in (A) the distance between the nozzle’s tip and the substrate was calibrated to be the thickness of a piece of standard 80 gsm paper (ca. 0.1 mm). * no deposition of filaments. When printing into gellan gum suspension media, printing speeds as high as 60 mm.s-1 still resulted in continuous printed filaments with minimal irregularities, whereas for printing onto TCPS, 10 mm.s-1 was the maximum achievable speed before breaking up of filaments occurred (Fig 3). During direct extrusion-based printing onto a solid substrate, the balance between the ink extrusion velocity and nozzle translational velocity as well as the distance between the nozzle orifice and substrate (stand-off distance), determines whether straight lines with a constant diameter can be printed [19]. We observe that as nozzle translational velocities (where stand-off distance is constant) are decreased, filaments printed onto TCPS maintained their straightness but increased in diameter. In contrast, when printing into the suspension media, decreasing nozzle translational velocities resulted in the deposition of tortuous filaments (alongside increased diameters). This is due to the meandering instability of viscous threads [20] which in air is typically only seen for printing with fluids with viscosities that are orders of magnitude higher, such as in the electrospinning of polymer melts [21]. Similar to conventional printing onto TCPS, filaments printed in the suspension media exhibited a decrease in diameter with increasing translational speed at a constant flow rate (Fig 3b). For example, as nozzle translational velocity was increased from 2 mm·s-1 to 40 mm·s-1, filament diameter decreased from 0.87 ± 0.08 mm to 0.20 ± 0.03 mm, respectively (n = 10). Comparison of diameters of between filaments printed in suspension media and those printed on TCPS revealed a slight increase in diameter for filaments printed in the media for equivalent translational speeds. It should be noted here that all printing was carried out using a conical nozzle, which requires a lower pressure to obtain similar flow rates of ink in comparison to straight nozzles (S1 Fig). Next, gelMA-based bioinks were jetted into gellan gum granular gels using an electromagnetic droplet printing jet, which combines air pressure with the open-close action of a magnetic ball valve. GelMA droplets were deposited using various extrusion pneumatic pressures in suspension media incubated for 30 min at various temperatures prior to printing, and droplet size and circularity were studied (Fig 4). Droplets were found to exhibit an elongated, bullet-like shape (S2 Fig). Droplet size depended strongly on extrusion pressure, but not on the temperature of the gellan gum granular gel in the range studied (Fig 4b). Conversely, the circularity of the droplet was found to be independent of extrusion pressure (around 0.57 for all pressures, n = 9), but showed a degree of dependence on the temperature of the granular gel. Droplet circularity was defined by the equation 4·π·(area/perimeter2) with a value of 1.0 indicating a perfect circle. Varying the temperature of the gellan gum suspension media revealed that at 4°C, values of circularity for the droplets were low, around 0.36. Circularity was higher at 15 and 37°C, with no significant difference in circularity between these temperatures. Droplet bioprinting into gellan gum suspension media at various media temperatures. Ink/cartridge temperature = 37°C, nozzle = 300 μm straight nozzle. (A) Bright field micrographs of 10% (w/v) gelMA bioink droplets. (scale bars: 500 μm). (B) Effect of extrusion pressure and granular gel incubation temperature on either the droplet size or the droplet circularity (n = 3). Printed gelMA droplets laden with fluorescent CFPAC-1 GFP human pancreatic cancer cells are shown in Fig 5a. To achieve this, it was necessary to supplement the granular gel medium with 0.05 wt% LAP photo-initiator prior to printing, to prevent the loss of LAP from the ink droplet into the surrounding medium through diffusion. CFPAC-1 GFP cells maintained high fluorescence intensity from Day 0 to Day 1 in culture. Fluorescence intensity did decrease over 7 days of cell culture, which could have a variety of causes as elaborated on in the Discussion. Cell-laden bioink droplets printed into gellan gum suspension media. (A) Brightfield and fluorescent images of a bioink droplet of 10% w/v gelMA + 0.05% w/v LAP laden with 3.5·106 CFPAC-1 GFP mammalian cells∙mL-1 (scale bars: 500 μm). Droplet was incubated at 37°C for 7 days and was shown to remain stable and not completely dissolve. (B) Suspension media incubation temperature (10 or 37°C) was varied to show that cell-laden gelMA bioink droplets could be fused together using the temperature of the suspension medium. Bioinks were formulated from 10% w/v gelMA + 0.05% w/v LAP with either CFPAC-1 GFP (green) or U87-MG RFP (red) at 2·106 cells∙mL-1 (scale bars: 500 μm). Additionally, constructs were fabricated containing two distinct zones each with a different cell population (Fig 5b). Two gelMA bioink formulations, containing either CFPAC-1 GFP or U87-MG Cherry cells, were deposited subsequently next to one another in granular gels, pre-incubated at either 10 or 37°C. These temperatures span across the melting temperature of the gelMA component of the ink, which appeared to have a critical impact on the ability of the droplets to fuse into a single construct. At a printing temperature of 10°C the droplets dispersed upon subsequent dilution of the suspension media, while at the higher printing temperature of 37°C the droplets were permanently fused. This indicated fusion of multi-material droplets was prevented by thermal gelation of the ink. This underscores the importance of the ability to use the suspension media at different temperatures. 3.3 Photo-curable suspension media Next, we explored the possibility of rendering the gellan gum suspension media photo-curable through addition of gelMA. GelMA was added at 5–10 wt% to a 0.3 wt% gellan gum granular gel and used at 37°C. Using a fluorescently labelled gelMA (10% w/v) ink, a non self-supporting helix structure was printed successfully in the media with or without added gelMA (Fig 6). Post printing, the whole construct was exposed to 405 nm light. When using only gellan gum in the suspension medium, only the printed feature was crosslinked and thus could be liberated from its immobilised state upon dilution with PBS. However, when the suspension medium contained gelMA as well, both the ink and suspension media were crosslinked. The complete construct was then removed from the beaker which held the volume of the suspension media (Fig 6b) and could be incubated at 37°C without melting of either the construct or the printed features occurring. Crosslinkable suspension medium consisting of gelMA and gellan gum granular gel. (A) 3D printed, non-self-supporting helix printed using a fluorescein isothiocyanate (FITC) labelled gelMA hydrogel ink, printed in a gellan gum granular gel, in daylight (left) and 405 nm UV light (right). (scale bar: 10 mm). (B) Photo-cured hydrogel construct, where gelMA-FITC hydrogel helix printed in a gelMA and gellan gum suspension medium, in daylight (left) and 405 nm UV light (right). (scale bars: 10 mm). (C) Comparison of Young’s modulus of chemically crosslinked gelMA hydrogels and gelMA + gellan gum granular gel (i.e. photo-curable suspension media) n = 5. Photo-curable suspension media could be created using different gelMA concentrations, resulting in different final mechanical properties (Fig 6c). Young’s modulus, a key determinant of the functionality of cells cultured within 3D hydrogels for tissue engineering [22], ranged from 0.9–9.3 kPa for neat gelMA gels at concentrations between 5 and 10%, respectively. The presence of 0.3% w/v gellan gum granules roughly doubled the stiffness compared to neat gelMA, as the photo-curable suspension media exhibited Young’s moduli values in the range of 1.9–17.5 kPa. For both conditions, the modulus (E) followed a power law (as is typically observed for such gels [23]) with a similar exponent value: E = 0.0113·c3.1739 for gels prepared with gelMA and gellan gum granular gel, and E = 0.0035·c3.3934 for neat gelMA hydrogels, where c is the gelMA concentration (% w/v). 4. Discussion In this work, we present a methodology for facile production of gellan gum granular gels for use as a suspension media for biofabrication applications. Through the application of a shearing force during the sol-gel transition of gellan gum solutions containing monovalent ions, we were able to rapidly create dense suspensions of gellan gum granules rather than a bulk, solid gel. We observe these granules to be highly irregular in shape, similar to the agarose granules developed by Senior et al. [24], with the spindles extending from the granule body promoting a high degree of interlinking between granules. The granular gels behaved as yield stress fluids and exhibited time-dependent recovery of their solid-like properties after fluidisation and displacement of granules under the application of stress. We assessed the applicability of these gels for use with common biofabrication techniques such as extrusion 3D printing and micro-valve bioprinting, finding that the morphology of printed inks was greatly affected by the surrounding granular gel. When printing into suspension media, the ink’s temperature will quickly equilibrate to the suspension media temperature due to the large difference in volume. The temperature-dependency of suspension media is therefore critical for successful suspended printing, and possibly limits the range of inks that can be used in combination with it. For example, a gelatine-based ink combined with a gelatine-based granular gel support bath (necessarily below gelatine’s melting temperature) would quickly solidify and clog the nozzle. We demonstrated that gellan gum granular gels exhibit yield stress fluid behaviour over a range of temperatures, having yield stress values around 0.7 Pa at 37°C, 3 Pa at 20°C and exhibiting the capability to suspend droplets at temperatures as low as 4°C. We propose that, as such, these granular gels offer the opportunity to accommodate printing of a wide variety of ink formulations, demonstrating appropriate rheological behaviour over the full bioprinting temperature window. Furthermore, the existence of a yield stress at 37°C indicates that these granular gels can be used under cell culture conditions without loss of viscoplasticity. The yield stress values of our granular gels were observed to be lower than those for commonly used suspension media in the field, for example, Carbopol or alginate microparticle suspensions which exhibit yield stress values around 20–25 Pa [6] and 316 Pa [25] respectively, also measured at 1 Hz. The gellan gum granular gels presented here are therefore considered to fluidise with greater ease under the application of stress. Ease of fluidisation of the suspension media is advantageous for bioprinting applications as minimising resistance on the extruded ink as it flows from the nozzle. A comparison between filament morphology and diameter when printing in our suspension medium versus printing on a TCP substrate, showed that filament morphology tended towards one of higher tortuosity while filament diameter increased when printing was conducted in the suspension medium. This comparison was performed over a range of nozzle translational speeds. While it has been previously discussed that filament deposition can be affected by ink rheology, for example viscoelasticity and yield stress [19, 26], these results highlight the importance that the print substrate, environment surrounding the nozzle and the relationship between the nozzle translational speed and the velocity of the extrudate leaving the nozzle, all contribute towards the resolution of a deposited filament. Filaments printed in air exhibited a small but significant reduction in diameter with increasing translational nozzle speed and maintained a smooth morphology, typical for hydrogels printed in air on a solid substrate [27]. In this case, filament morphology and diameter may be attributed towards several phenomena. It is likely that smoothing of the filament is partially the result of surface tension occurring at the air-ink interface with a rise in the Laplace pressure acting on the extrudate [28]. An additional contributing factor is likely the effects of extrudate swell (Barus effect), where there is release of the compressive forces that cause the contraction of hydrogel polymer chains as the extrudate leaves the nozzle orifice [9]. The morphology, including diameter, of the filament may also be influenced by the ink-substrate contact angle, where angles < 90° can cause large deformations and spreading of the hydrogel ink on the substrate [28]. Meanwhile, the observed decrease in filament diameter as nozzle translational speed is increased, likely relates to the printing speed exceeding the speed of material being extruded from the nozzle, causing the filament to become stretched [19]. While the resolution of printed filaments in air is the summation of a number of different phenomena, printing in a suspension medium significantly influences their contributions to affecting the morphology of the filaments. Printing in our gellan gum granular gels, which primarily constitute water, will significantly reduce the action of surface tension forces on the printed filaments thus inhibiting filament contraction due to Laplace pressure. This meandering instability of viscous threads is very well described in literature [20], including in the context of suspended extrusion printing [29] and is governed by the viscoelastic properties of both the suspension bath and ink. Similarly to printing in air, the decrease in filament diameter with increasing print speed, suggests the hydrogel ink may be being anchored to the gellan granules, causing stretching and thinning of the filament. The tortuosity we observe when printing in these granular gels may be exploited for engineering tissue structures where a high degree of folding is present in the native architecture for example in brain tissue or the epithelium of the small intestine [30, 31]. Following on, we assessed the applicability of gellan gum granular gels to micro-valve jetting—an important technique for controlling the spatial organisation of distinct small cell populations, e.g., for in vitro tissues for high-throughput drug testing. Droplets deposited in air are mostly spherical being driven primarily by surface tension, however droplets printed in our granular gels were found to adopt an elongated, cylindrical shape. In the absence of high interfacial forces that favour spherical droplet formation, the volume of ink ejected from the nozzle tip maintains a geometry closer resembling that prior to being ejected from the nozzle. We observed some swelling of droplets where their projected surface area was higher than the surface area of the nozzle orifice, which is a common occurrence when using pneumatic based printing systems [9]. This macroscopic swelling is driven by the phenomenon known as the Barus effect, mentioned previously. As such, it was anticipated droplets would exhibit high surface areas. More interestingly, the circularity of droplets showed a dependence not on extrusion pressure but on the temperature of the granular gel. We hypothesise that the irregular droplet surface is caused by the ink being pushed into the interstitial space between the gellan gum granules as the volume of ink is injected. At 4°C, rapid heat loss from the small ink droplet (at 37°C) to the cold surrounding media causes fast gelation and fixation of the irregular shape, resulting in low circularity values. At 37°C, the interfacial forces act to cause a degree of relaxation of the ink into a spherical shape as the volume of gelMA ink doesn’t solidify at that temperature. With no significant change between circularity values of droplets at 15 and 37°C, it could be considered that at 15°C the action of any interfacial forces on the ink is occurring fast relative to the gelation of the gelMA. With current extrusion-based bioprinting strategies, the fabrication of clinically relevant volumes of tissue requires long print times, where incidences of cell-death are increased [32]. Here, we used a photo-curable suspension media to fabricate a construct with dimensions greater than several millimetres, utilising the addition of gelMA in our gellan gum granular gels. Photo-curing is commonly used for the encapsulation of cells in hydrogels [33]. Photo-curing of the suspension media removes the need to extrude the bulk of tissue construct line-by-line, while the yield stress of the gellan gum granular gel permits the capability to engineer features/regions in the medium with compositions and properties that differ from the bulk medium. The Young’s modulus was found to increase by about twofold when gelMA gels were prepared with gellan gum granular gels, which was roughly in line with earlier observations of photo-cured solutions of gelMA and gellan gum, though in that case the gellan gum was not in particle form [34]. This methodology for rapidly engineering large constructs presents a different option from methods such as casting of cell-laden gel as bulk tissues [35], with omnidirectional printing in the suspension media allows complex features to be deposited anywhere in the bulk gel. 5. Conclusion In summary, gellan gum granular gels were developed using simultaneous shearing and cooling of polymer solutions through their sol-gel transition temperature in the presence of monovalent cations. These gels were developed to offer a method for depositing water-rich biomaterials in a 3D environment, thus alleviating some of the inherent limitations of direct extrusion 3D printing in air, where fabricating structures of high complexity that require mechanical support are not possible. Due to these gels exhibiting viscoplasticity at 37°C, this enables bioprinting of cell-laden bioinks at optimum biological temperatures that are more permissive to cell survival. Furthermore, we discuss the implications of printing in these exceptionally low yield stress granular gels, detailing the challenges of predicting shape fidelity that arise from factors such as a reduction in surface tension compared to printing in air, and the ease of displacement of the granules by the nozzle and extrudate. Lastly, in response to the current challenge within the tissue engineering field of bioprinting large functional tissues, we looked at the feasibility of developing a photo-curable suspension media. To achieve this, the addition of gelMA to the gellan gum granular gels was utilised, showing the possibility to print gelMA inks within this photo-curable suspension media. We foresee this strategy could be exploited to embed cells or organoids and print surrounding vascular channels all within the same bulk suspension medium. Supporting information Effect of nozzle selection on filament fidelity, when printing into a gellan gum fluid gel. Both the conical and straight nozzles have an inner diameter of 25G. (scale bars: 5 mm). The straight nozzle permitted printing at a high pressure compared to the conical nozzle, negating the over-deposition of ink seen when printing with this nozzle. Printing parameters: ink formulation = 30% w/v poloxamer, print temperature = 30°C. The distance between the nozzle’s tip and the substrate was calibrated to be the thickness of a piece of standard 80 gsm paper. (TIF) Evaluation of typical droplet shape when extruded in a gellan gum granular gel. Droplet printed with a gelMA-based bioink. The droplet was photocured in the granular gel, prior to unjamming of granular gel with culture media to permit rotation of the droplet and imaging in the z-plane. (scale bars: 500 μm). (TIF) (ZIP) (ZIP) (ZIP) (ZIP) 10 Sep 2024 PONE-D-24-32977Gellan gum-based granular gels as suspension media for biofabricationPLOS ONE Dear Dr. Melchels, Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process. Please submit your revised manuscript by Oct 23 2024 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org. When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file. Please include the following items when submitting your revised manuscript:A rebuttal letter that responds to each point raised by the academic editor and reviewer(s). You should upload this letter as a separate file labeled 'Response to Reviewers'.A marked-up copy of your manuscript that highlights changes made to the original version. You should upload this as a separate file labeled 'Revised Manuscript with Track Changes'.An unmarked version of your revised paper without tracked changes. You should upload this as a separate file labeled 'Manuscript'. A rebuttal letter that responds to each point raised by the academic editor and reviewer(s). You should upload this letter as a separate file labeled 'Response to Reviewers'. A rebuttal letter that responds to each point raised by the academic editor and reviewer(s). You should upload this letter as a separate file labeled 'Response to Reviewers'. A marked-up copy of your manuscript that highlights changes made to the original version. You should upload this as a separate file labeled 'Revised Manuscript with Track Changes'. A marked-up copy of your manuscript that highlights changes made to the original version. You should upload this as a separate file labeled 'Revised Manuscript with Track Changes'. An unmarked version of your revised paper without tracked changes. You should upload this as a separate file labeled 'Manuscript'. An unmarked version of your revised paper without tracked changes. You should upload this as a separate file labeled 'Manuscript'. If you would like to make changes to your financial disclosure, please include your updated statement in your cover letter. Guidelines for resubmitting your figure files are available below the reviewer comments at the end of this letter. If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: https://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols. Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-email&utm_source=authorletters&utm_campaign=protocols. We look forward to receiving your revised manuscript. Kind regards, Pradeep Kumar, Ph.D. Academic Editor PLOS ONE Journal Requirements: 1. When submitting your revision, we need you to address these additional requirements. Please ensure that your manuscript meets PLOS ONE's style requirements, including those for file naming. The PLOS ONE style templates can be found at https://journals.plos.org/plosone/s/file?id=wjVg/PLOSOne_formatting_sample_main_body.pdf and https://journals.plos.org/plosone/s/file?id=ba62/PLOSOne_formatting_sample_title_authors_affiliations.pdf. 2. Thank you for stating the following financial disclosure: [AM EP/R513040/1 Engineering and Physical Sciences Research Council through their Doctoral Training Programme https://www.ukri.org/councils/epsrc/]. Please state what role the funders took in the study. If the funders had no role, please state: ""The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript."" If this statement is not correct you must amend it as needed. Please include this amended Role of Funder statement in your cover letter; we will change the online submission form on your behalf. 3. Thank you for stating the following in the Acknowledgments Section of your manuscript: [We acknowledge the financial support from the Engineering and Physical Sciences Research Council through their Doctoral Training Programme (EP/R513040/1)] We note that you have provided funding information that is not currently declared in your Funding Statement. However, funding information should not appear in the Acknowledgments section or other areas of your manuscript. We will only publish funding information present in the Funding Statement section of the online submission form. Please remove any funding-related text from the manuscript and let us know how you would like to update your Funding Statement. Currently, your Funding Statement reads as follows: [AM EP/R513040/1 Engineering and Physical Sciences Research Council through their Doctoral Training Programme https://www.ukri.org/councils/epsrc/]. Please include your amended statements within your cover letter; we will change the online submission form on your behalf. [Note: HTML markup is below. Please do not edit.] Reviewers' comments: Reviewer's Responses to Questions Comments to the Author 1. Is the manuscript technically sound, and do the data support the conclusions? The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented. Reviewer #1: Yes Reviewer #2: Yes ********** 2. Has the statistical analysis been performed appropriately and rigorously? Reviewer #1: Yes Reviewer #2: Yes ********** 3. Have the authors made all data underlying the findings in their manuscript fully available? The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified. Reviewer #1: No Reviewer #2: Yes ********** 4. Is the manuscript presented in an intelligible fashion and written in standard English? PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here. Reviewer #1: Yes Reviewer #2: Yes ********** 5. Review Comments to the Author Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters) Reviewer #1: This paper presents a new method to create gellan gum based suspension media for extrusion bioprinting. The rheological properties of the obtained suspension baths were found favorable over a wide range of temperatures (4-37 degrees Celsius). This is a remarkable property because it enables to set the suspension bath's temperature to the optimal print nozzle temperature according to the requirements imposed by the bioink. Moreover, the study illustrates the use of the novel suspension media in the context of both extrusion-based printing and micro-valve bioprinting. In my opinion, this is a valuable contribution to the bioprinting literature and its impact could be further increased by addressing the following weak points: 1. The terms "droplet printing by jetting" (line 221), "electromagnetic droplet printing" (line 334), and "droplet jetting" (line 370) are confusing because they deviate from the professional jargon of bioprinting. Please use instead "micro-valve bioprinting", the common term described in detail in the following references (I am not a coauthor of them): Gudapati H et al. A comprehensive review on droplet-based bioprinting: past, present and future. Biomaterials 2016, 102, doi:10.1016/j.biomaterials.2016.06.012. Sun W et al. The bioprinting roadmap. Biofabrication 2020, 12, 022002, doi:10.1088/1758-5090/ab5158. 2. The description of extruded strand morphology versus nozzle translational velocity (printing speed) (lines 239-241) is accurate but too narrow. It is important to note that tortuous strands can result also in direct extrusion-based printing onto solid substrates provided that the stand-off distance is large enough and the printing speed is set well below the extrusion speed. The following work by Yuk and Zhao is an excellent study of strand morphology in direct ink writing: Yuk H and Zhao X. A New 3D Printing Strategy by Harnessing Deformation, Instability, and Fracture of Viscoelastic Inks. Advanced Materials 2018, 30, 1704028, doi:10.1002/adma.201704028. 3. The list of printing parameters provided in the captions of Figures 3 and S1 should also include the stand-off distance (the distance between the nozzle's tip and the substrate). 4. In the Discussion, the authors suggest that the thinning of an extruded hydrogel strand with increasing printing speed occurs due to surface tension (lines 360-361). It is true, the Laplace pressure, of the order of hundreds of Pa in the case of the air-ink interface, contributes to smoothing the extruded strand. Nevertheless, the strand's diameter is determined by volume conservation, which explains why it is inversely proportional to the square root of the printing speed. The print resolution is also influenced by the extrudate swell effect (also known as the Barus effect or die-swelling): as the extruded hydrogel strand leaves the nozzle, its diameter becomes larger than the nozzle's orifice because of the relaxation of the hydrogel's polymer filament network. This effect is mentioned by the authors on line 379, in the context of droplet bioprinting. If the printing speed matches the dispensing velocity (extrusion speed) the filament is deposited as is (i.e. its diameter will be equal to the nozzle's inner diameter multiplied by the extrudate swell ratio). If the printing speed exceeds the extrusion speed, the filament is stretched on-the-fly (since it is anchored to the substrate by adhesion forces) and its diameter can be computed from volume conservation. Upon deposition onto a solid substrate (e.g. TCPS), it flattens to a certain extent, depending on the ink-substrate contact angle as well as on the ink's yield stress and shear thinning behavior. I apologize for this long comment! I did not intend to lecture the authors; I just tried to illustrate how complex a problem is to predict the resolution of extrusion-based bioprinting. Theoretical studies are available in the literature for both direct and suspended extrusion bioprinting. The authors have the option to extend their discussion, providing a more accurate description of the observed fenomena, or to refrain from discussing the mechanisms responsible for their experimental findings. 5. Section 5 (Conclusion) is, in fact, a reiteration of the Abstract. In this part, it is fine to start with a brief summary of what has been achieved, but one should also attempt to explain the potential impact of the reported results and the perspectives of the proposed approach. Such comments are included the Discussion, but no take-home message is provided in the last section. Minor remarks and revisions: Line 19: I would stick to a single tense in the Abstract. It starts in simple present and switches midway to past tense. One option is to reformulate "Furthermore, printing of cell-laden droplets maintained over 7-day was demonstrated" as "Furthermore, we demonstrate the printing of cell-laden droplets maintained over 7 days". Line 179: In the paragraph dedicated to statistical analysis, please state that "The level of statistical significance was set to p = 0.05." Lines 223-224: Here, I would write "gellan gum suspension media (GGSM)" and "tissue culture polystyrene (TCPS)" (i.e. without 3D and 2D, respectively.) These are the acronyms used later on. Line 252 and 257: Instead of "S1", please write "Supporting Information, Figure S1" and then, on line 257, please replace "S2" with "Figure S2". Line 300: Instead of "Following printing of this structure," I would write "Post printing,". Line 313: In the caption of Figure 6, I would keep "n = 5" as part of the sentence: instead of " suspension media). n =5" I would write " suspension media; n = 5)." Line 316: Instead of "The Young’s moduli, a key determinant" consider writing "Young’s modulus, a key determinant". Lines 321-323: Mathematical symbols (E, c) are usually typeset in Italic, using an equation editor. Line 390: Instead of "extrusion-based printing", please write "extrusion-based bioprinting". Line 397: Please replace "by approximately 2x" with "about twofold". Line 408: Please consider revising "permitting the ability" as "allowing". Reviewer #2: The manuscript discusses work pertaining to the suitability of granular gellan gum gels as suspension media for 3D bioprinting of cell-laden inks. The effects of gel concentration, temperature and rheology are described in terms of how such granular gels support 3D printed structures while achieving suitable printing speeds and resolutions. The manuscript is concise and well-written in a simple manner which makes it understandable and readable to various academic levels of audience. The rationale of the study is well-outlined in the introduction. The results support the hypothesis and reflect the objectives of the study. Below are some minor points to consider: 1. Line 19: amend to " 7 days" 2. Line 58: "suspension media" 3. Reference should be included for lines 67-68 4. Suggested to include a brief definition or explanation of "jammed granular network" in the introduction. 5. In materials and methods, it is suggested to include the concentrations of gellan gum and gelMA used, including the ratios of gellan gum:gelMA for the photo-curable medium. 5. Please include the time duration of shearing of the gellan gum gels at 600 rpm. 6. Line 127: replace full stop with a comma between "stress-controlled" and "single frequency. 7. Line 149: "G-code" include hyphen. 8. Line 169: amend to ",...which contained bubbles were excluded, n = 5..." 9. Line 367: amend to "brain tissue or of the epithelium of..." ********** 6. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy. Reviewer #1: No Reviewer #2: No ********** [NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.] While revising your submission, please upload your figure files to the Preflight Analysis and Conversion Engine (PACE) digital diagnostic tool, https://pacev2.apexcovantage.com/. PACE helps ensure that figures meet PLOS requirements. To use PACE, you must first register as a user. Registration is free. Then, login and navigate to the UPLOAD tab, where you will find detailed instructions on how to use the tool. If you encounter any issues or have any questions when using PACE, please email PLOS at figures@plos.org. Please note that Supporting Information files do not need this step. 24 Sep 2024 We would like to thank the reviewers for their thoughtful comments. Please find below our point-by-point response to the reviewer reports for our manuscript. Reviewer #1 1. The terms "droplet printing by jetting" (line 221), "electromagnetic droplet printing" (line 334), and "droplet jetting" (line 370) are confusing because they deviate from the professional jargon of bioprinting. Please use instead "micro-valve bioprinting", the common term described in detail in the following references (I am not a coauthor of them) Response: We have updated these terms as suggested by the reviewer, including the references to provide additional information to the readers on micro-valve bioprinting. 2. The description of extruded strand morphology versus nozzle translational velocity (printing speed) (lines 239-241) is accurate but too narrow. It is important to note that tortuous strands can result also in direct extrusion-based printing onto solid substrates provided that the stand-off distance is large enough and the printing speed is set well below the extrusion speed. The following work by Yuk and Zhao is an excellent study of strand morphology in direct ink writing Response: We would like to thank the reviewer for highlighting there are additional printing parameters which can affect printed strand morphology aswell as providing a reference - it is indeed some interesting work that we find worthy of a mention in our manuscript. We have rephrased some of the text to provide the reader with a more nuanced understanding of printing straight lines using direct extrusion-based printing, while including this reference. See below, (lines 250-254) During direct extrusion-based printing onto a solid substrate, the balance between the ink extrusion velocity and nozzle translational velocity aswell as the distance between the nozzle orifice and substrate (stand-off distance), determines whether straight lines with a constant diameter can be printed (19). We observe that as nozzle translational velocities (where stand-off distance is constant) are decreased, filaments printed onto TCPS maintained their straightness but increased in diameter. 3. The list of printing parameters provided in the captions of Figures 3 and S1 should also include the stand-off distance (the distance between the nozzle's tip and the substrate). Response: In these experiments, manual calibration was conducted where the distance between nozzle tip and substrate was the thickness of a piece of standard 80 gsm paper (around 0.1mm). To inform readers of this we have adapted the captions in both Figures to include this information stating, “the distance between the nozzle's tip and the substrate was calibrated to be the thickness of a piece of standard 80 gsm paper (ca. 0.1 mm).” 4. In the Discussion, the authors suggest that the thinning of an extruded hydrogel strand with increasing printing speed occurs due to surface tension (lines 360-361). It is true, the Laplace pressure, of the order of hundreds of Pa in the case of the air-ink interface, contributes to smoothing the extruded strand. Nevertheless, the strand's diameter is determined by volume conservation, which explains why it is inversely proportional to the square root of the printing speed. The print resolution is also influenced by the extrudate swell effect (also known as the Barus effect or die-swelling): as the extruded hydrogel strand leaves the nozzle, its diameter becomes larger than the nozzle's orifice because of the relaxation of the hydrogel's polymer filament network. This effect is mentioned by the authors on line 379, in the context of droplet bioprinting. If the printing speed matches the dispensing velocity (extrusion speed) the filament is deposited as is (i.e. its diameter will be equal to the nozzle's inner diameter multiplied by the extrudate swell ratio). If the printing speed exceeds the extrusion speed, the filament is stretched on-the-fly (since it is anchored to the substrate by adhesion forces) and its diameter can be computed from volume conservation. Upon deposition onto a solid substrate (e.g. TCPS), it flattens to a certain extent, depending on the ink-substrate contact angle as well as on the ink's yield stress and shear thinning behavior. Response: We would like to thank the reviewer for their very insightful and well explained comments on the variables which contribute towards diameter/smoothness of printed filaments. We find these comments to be useful and should be addressed in our manuscript. We have extended the discussion to include the following text. (line 369 – 400) A comparison between filament morphology and diameter when printing in our suspension medium versus printing on a TCP substrate, showed that filament morphology tended towards one of higher tortuosity while filament diameter increased when printing was conducted in the suspension medium. This comparison was performed over a range of nozzle translational speeds. While it has been previously discussed that filament deposition can be affected by ink rheology, for example viscoelasticity and yield stress (Paxton et al., 2016; Yuk & Zhao, 2018), these results highlight the importance that the print substrate, environment surrounding the nozzle and the relationship between the nozzle translational speed and the velocity of the extrudate leaving the nozzle, all contribute towards the resolution of a deposited filament. Filaments printed in air exhibited a small but significant reduction in diameter with increasing translational nozzle speed and maintained a smooth morphology, typical for hydrogels printed in air on a solid substrate (Webb & Doyle, 2017). In this case, filament morphology and diameter may be attributed towards several phenomena. It is likely that smoothing of the filament is partially the result of surface tension occurring at the air-ink interface with a rise in the Laplace pressure acting on the extrudate (Ning et al., 2020). An additional contributing factor is likely the effects of extrudate swell (Barus effect), where there is release of the compressive forces that cause the contraction of hydrogel polymer chains as the extrudate leaves the nozzle orifice (Cooke & Rosenzweig, 2021). The morphology, including diameter, of the filament may also be influenced by the ink-substrate contact angle, where angles < 90° can cause large deformations and spreading of the hydrogel ink on the substrate (Ning et al., 2020). Meanwhile, the observed decrease in filament diameter as nozzle translational speed is increased, likely relates to the printing speed exceeding the speed of material being extruded from the nozzle, causing the filament to become stretched (Yuk & Zhao, 2018). While the resolution of printed filaments in air is the summation of a number of different phenomena, printing in a suspension medium significantly influences their contributions to affecting the morphology of the filaments. Printing in our gellan gum granular gels, which primarily constitute water, will significantly reduce the action of surface tension forces on the printed filaments thus inhibiting filament contraction due to Laplace pressure. This meandering instability of viscous threads is very well described in literature (Morris et al., 2008), including in the context of suspended extrusion printing (Prendergast & Burdick, 2021) and is governed by the viscoelastic properties of both the suspension bath and ink. Similarly to printing in air, the decrease in filament diameter with increasing print speed, suggests the hydrogel ink may be being anchored to the gellan granules, causing stretching and thinning of the filament. The tortuosity we observe when printing in these granular gels may be exploited for engineering tissue structures where a high degree of folding is present in the native architecture for example in brain tissue or the epithelium of the small intestine (Brassard et al., 2021; Gjorevski et al., 2016). 5. Section 5 (Conclusion) is, in fact, a reiteration of the Abstract. In this part, it is fine to start with a brief summary of what has been achieved, but one should also attempt to explain the potential impact of the reported results and the perspectives of the proposed approach. Such comments are included the Discussion, but no take-home message is provided in the last section. Response: We would like to thank the reviewer for the attentiveness here and agreed that the conclusion requires improvement. We thus have taken steps to reword the conclusion. Please see below. (line 434-449) In summary, gellan gum granular gels were developed using simultaneous shearing and cooling polymer solutions through their sol-gel transition temperature in the presence of monovalent cations. These gels were developed to offer a method for depositing water-rich biomaterials in a 3D environment, thus alleviating some of the inherent limitations of direct extrusion 3D printing in air, where fabricating structures of high complexity that require mechanical support are not possible. Due to these gels exhibiting viscoplasticity at 37 °C, this enables bioprinting of cell-laden bioinks at optimum biological temperatures that are more permissive to cell survival. Furthermore, we discuss the implications of printing in these exceptionally low yield stress granular gels, detailing the challenges of predicting shape fidelity that arise from factors such as a reduction in surface tension compared to printing in air, and the ease of displacement of the granules by the nozzle and extrudate. Lastly, in response to the current challenge within the tissue engineering field of bioprinting large functional tissues, we looked at the feasibility of developing a photo-curable suspension media. To achieve this, the addition of gelMA to the gellan gum granular gels was utilised, showing the possibility to print gelMA inks within this photo-curable suspension media. We foresee this strategy could be exploited to embed cells or organoids and print surrounding vascular channels all within the same bulk suspension medium. Minor remarks and revisions: Response: These minor revisions were very helpful to improving the quality of the manuscript and have been addressed in the manuscript. Reviewer #2 We would like to thank the reviewer for their comments and detail-orientated focus on the manuscript – we believe this to have helped improve the quality of the work. All of the suggested revisions have been revised, notably including a definition of jammed granular network. Submitted filename: Response to reviewers.docx 14 Oct 2024 Gellan gum-based granular gels as suspension media for biofabrication PONE-D-24-32977R1 Dear Dr. Melchels, We’re pleased to inform you that your manuscript has been judged scientifically suitable for publication and will be formally accepted for publication once it meets all outstanding technical requirements. Within one week, you’ll receive an e-mail detailing the required amendments. When these have been addressed, you’ll receive a formal acceptance letter and your manuscript will be scheduled for publication. An invoice will be generated when your article is formally accepted. Please note, if your institution has a publishing partnership with PLOS and your article meets the relevant criteria, all or part of your publication costs will be covered. Please make sure your user information is up-to-date by logging into Editorial Manager at Editorial Manager® and clicking the ‘Update My Information' link at the top of the page. If you have any questions relating to publication charges, please contact our Author Billing department directly at authorbilling@plos.org. If your institution or institutions have a press office, please notify them about your upcoming paper to help maximize its impact. If they’ll be preparing press materials, please inform our press team as soon as possible -- no later than 48 hours after receiving the formal acceptance. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org. Kind regards, Pradeep Kumar, Ph.D. Academic Editor PLOS ONE Additional Editor Comments (optional): Reviewers' comments: Reviewer's Responses to Questions Comments to the Author 1. If the authors have adequately addressed your comments raised in a previous round of review and you feel that this manuscript is now acceptable for publication, you may indicate that here to bypass the “Comments to the Author” section, enter your conflict of interest statement in the “Confidential to Editor” section, and submit your "Accept" recommendation. Reviewer #1: All comments have been addressed Reviewer #2: All comments have been addressed ********** 2. Is the manuscript technically sound, and do the data support the conclusions? The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented. Reviewer #1: Yes Reviewer #2: Yes ********** 3. Has the statistical analysis been performed appropriately and rigorously? Reviewer #1: Yes Reviewer #2: Yes ********** 4. Have the authors made all data underlying the findings in their manuscript fully available? The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified. Reviewer #1: Yes Reviewer #2: Yes ********** 5. Is the manuscript presented in an intelligible fashion and written in standard English? PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here. Reviewer #1: Yes Reviewer #2: Yes ********** 6. Review Comments to the Author Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters) Reviewer #1: The authors have addressed all the concerns expressed in my previous referee report. I think this is a nice paper that might elicit the interest of the bioprinting community. Reviewer #2: All comments have been addressed. I believe this manuscript can be accepted for publication. ********** 7. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy. Reviewer #1: No Reviewer #2: No ********** 17 Oct 2024 PONE-D-24-32977R1 PLOS ONE Dear Dr. Melchels, I'm pleased to inform you that your manuscript has been deemed suitable for publication in PLOS ONE. Congratulations! Your manuscript is now being handed over to our production team. At this stage, our production department will prepare your paper for publication. This includes ensuring the following: * All references, tables, and figures are properly cited * All relevant supporting information is included in the manuscript submission, * There are no issues that prevent the paper from being properly typeset If revisions are needed, the production department will contact you directly to resolve them. If no revisions are needed, you will receive an email when the publication date has been set. At this time, we do not offer pre-publication proofs to authors during production of the accepted work. Please keep in mind that we are working through a large volume of accepted articles, so please give us a few weeks to review your paper and let you know the next and final steps. Lastly, if your institution or institutions have a press office, please let them know about your upcoming paper now to help maximize its impact. If they'll be preparing press materials, please inform our press team within the next 48 hours. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org. If we can help with anything else, please email us at customercare@plos.org. Thank you for submitting your work to PLOS ONE and supporting open access. Kind regards, PLOS ONE Editorial Office Staff on behalf of Prof. Pradeep Kumar Academic Editor PLOS ONE