The pressure control of independent load port electro-hydraulic load simulation system using fixed time integral sliding mode active disturbance rejection Authors: He Hao, Hao Yan Published: 2024 ABSTRACT AbstractTo address the issues of motion disturbance and low loading accuracy in electro-hydraulic load simulation systems, and to effectively mitigate the impact of uncertainty on system performance, this paper proposes a novel independent load port electro-hydraulic load simulation system. A nonlinear variable structure state equation is derived to describe the pressure working states of the left and right chambers of the servo valve and hydraulic cylinder under loading conditions. In light of the presence of substantial motion disturbances, an integrated sliding mode automatic disturbance rejection composite controller is proposed with a focus on fixed-time convergence. To mitigate system chattering and enhance system loading performance and disturbance immunity, a fixed-time integral sliding mode controller was developed within the framework of active disturbance rejection control. Stability analysis was also carried out. Simulation research demonstrates that the pressure control accuracy of the composite controller is 99.88%, 99.86%, and 99.83% respectively when the system step command is given with disturbance frequencies of 1 Hz, 3 Hz, and 5 Hz. Similarly, under the same disturbance frequencies, the pressure control accuracy is 99.88%, 99.86%, and 99.84% respectively when the system sine command is given. The simulation results demonstrate that the independent load port electro-hydraulic load simulation system exhibits a notable energy-saving effect. Specifically, energy savings of around 45% and 48% were achieved compared to the original system. The research and exploration conducted have laid a strong groundwork for future in-depth studies on the independent load port electro-hydraulic load simulation system.Keywords: Independent load port, Electro-hydraulic load simulation system, Fixed time, Integral sliding modeSubject terms: Aerospace engineering, Mechanical engineering Introduction The electro-hydraulic load simulator is a crucial semi-physical simulation device. Its primary function is to simulate the expected forces encountered by the aircraft steering gear during testing, thereby facilitating the assessment of various technical indicators associated with the steering gear. The electro-hydraulic load simulation system offers several advantages, including rapid response times, substantial output power, and high load rigidity1,2. The electro-hydraulic servo system, characterized as a typical nonlinear time-varying system, exhibits a high level of nonlinearity and encompasses various model uncertainties, such as parameter uncertainty and nonlinearity uncertainty3–5. The electro-hydraulic load simulation system is significantly affected by external motion interference, which greatly limits the enhancement of system control performance and presents significant challenges to controlling the system6,7. Minimizing the impact of position disturbance on the loading performance of the electro-hydraulic load simulation system has emerged as a key technical problem. In recent years, efforts to enhance the control performance of electro-hydraulic load simulation systems have focused on compensating for the impact of position disturbances through two main categories. The first category involves control algorithm compensation methods, such as feedforward compensation based on the structural invariance principle8, disturbance observer compensation9, adaptive control10, fuzzy control11, neural network control12, and sliding mode variable structure control13. These methods aim to suppress disturbances through algorithm design at the software level. The second category comprises structural compensation methods, including pressure accumulator compensation14, dual-valve flow compensation15, and position synchronization compensation16. By improving the structure at the hardware level to reduce the impact of steering gear position disturbance. In order to solve the above problems, many advanced nonlinear control algorithms have been proposed to suppress disturbances and improve the loading control performance of the system. Jing et al.17. proposed novel dynamic surface disturbance rejection control with synchronous compensation, improve the tracking performance of simulator. Kang et al.18. proposed an almost disturbance decoupling (ADD) control strategy for solving the force problem of electro-hydraulic load simulator containing mechanical backlash. Wang et al.19. proposed a compound control scheme consists a synchronization controller and torque PI. Kang et al.20. addresses the force tracking problem of electro-hydraulic load simulator under influence nonlinear friction and uncertain disturbance. Yao et al.21. a system model is derived linear parameterization made adaptive control, then discontinuous projection-based robust controller developed. Helian et al.22. proposed a constrained strategy variable-speed pump-driven hydraulic actuator. Feng et al.23. proposed an improved describe between position, velocity direction, instability problem solved by stopping observation internal state. Daehee Won et al.24. proposed a method for nonlinear control using an extended state observer position tracking of electro-hydraulic system (EHS) with only feedback. Otto Cerman et al. Cerman et al.25. introduced An innovative approach to adaptive fuzzy sliding mode control for a class of SISO continuous nonlinear systems with unknown dynamics and bounded disturbances. The independent load port valve control system uses two or more valve groups to control the two cavities of the hydraulic cylinder separately, breaking the mechanical-hydraulic coupling between the inlet and outlet, and has been widely researched and applied. Professor Backe of Germany was the first to propose the concept of import and export independent control26, as early as 1987, he proposed the use of four plug-in valves to independently control the oil inlet and outlet of the hydraulic actuator, through different logic control, the hydraulic actuator can move in different directions. Li et al.27. to overcome obstacle, an independent metering valve-based configuration driven by servo pump control was proposed. Jing Yang et al.28. developed a strategy load force direction prediction two-chamber switching to verify feasibility working mode during change. Hu et al.29. proposed continuous for IMCS, based fuzzy principle, variable universe controller (VUFC) was designed. Shi et al.30. according to independent pump-valve hybrid principle, a position combined strategy based mode switching is proposed boom arm excavator. Ruqi Ding et al.31. presented novel electro-hydraulic improve Extended control degrees of freedom obtained utilizing independent metering valve electronic controlled pump. Karem Abuowda et al.32. reviewed advanced Independent Metering technology used in hydraulic systems. Based on the analysis presented, there is an issue with the accuracy of loading control in the electro-hydraulic load simulation system. This paper designs a novel independent load port electro-hydraulic load simulation system. The valve group of this system consists of 2 servo valves and are independently adjusted. This configuration differs from the traditional three-position four-way valve control system, as it enhances the degree of freedom in system control. The valve signals for the inlet and outlet can be provided separately based on the control requirements, enabling the actuator to function according to the specified instructions. Additionally, the back chamber pressure can be kept at a low level by increasing the opening of the outlet valve. Furthermore, while meeting the original system control requirements, it also considers energy-saving performance. Considering the complex working conditions of the variable structure of the independent load port electro-hydraulic load simulation system, we redefined the flow formulas for the inlet and outlet valves of the independent load port. Subsequently, we established its corresponding nonlinear mathematical model as the focus of our research. Addressing the constrained control precision of traditional ADRC in electro-hydraulic load simulation systems and the oscillation issue in sliding mode control, the paper introduces an innovative integral sliding mode active disturbance rejection composite control strategy that is centered on fixed time convergence (FISMADRC). An integral sliding mode controller with fixed time convergence is introduced based on the ADRC control framework. This approach enables the system to achieve rapid convergence and stability within a fixed time frame, independent of any initial state. Furthermore, it employs Lyapunov theory to demonstrate the stability of the control strategy and its convergence within the designated time. This approach aims to reduce the chattering problem in the control system resulting from uncertainty factors. The expanded state observer monitors both internal and external disturbances and uncertainties within the system and compensates for them at the control end. This process helps to achieve accurate pressure control while also enhancing the system’s robust performance and anti-interference capabilities. The composite controller proposed in this article demonstrates superior control effectiveness and energy-saving characteristics compared to both ADRC and PID control. Furthermore, it validates the efficacy of the proposed composite controller within the independent load port electro-hydraulic load simulation system. Overall, the main contributions of this paper are as follows: First, this paper proposes a novel independent load port electro-hydraulic load simulation system that integrates independent load port valve group control technology with the traditional electro-hydraulic load simulator’s control applications. This integration fully leverages the benefits of independent load port valve control technology, resulting in advantages such as rapid pressure response, high control accuracy, significant control flexibility, and robust resistance to disturbances. Second, the independent load port electro-hydraulic load simulation system operates under complex conditions characterized by multi-mode variable structures. To address the constantly changing complex working conditions, this paper reintroduces the valve port flow formula. Third, considering the limited accuracy of traditional ADRC and the chattering phenomenon associated with sliding mode control, we propose an integral sliding mode active disturbance rejection composite control strategy based on fixed-time convergence. This strategy builds upon the traditional ADRC framework by introducing a fixed-time integral sliding mode controller to replace the nonlinear PID controller. Ultimately, the energy-saving characteristics of the independent load port electro-hydraulic load simulation system were thoroughly analyzed based on the aforementioned control strategy. Valve-controlled independent load port variable structure model The working principle of the independent load port electro-hydraulic load simulation system is illustrated in Fig. 1. This figure features two distinct servo control systems. The left section of Fig. 1 depicts the loading control system, which comprises a loading cylinder, a servo valve, a pressure sensor, and a controller. Conversely, the right section of Fig. 1 presents the linear actuator, which serves as the position control system. The loading control system and the linear actuator are typically directly and rigidly connected, meaning that the active movement of the linear actuator directly influences the loading control system. Variations in the movement frequencies and amplitudes of the linear actuator can introduce disturbances to the input of the loading control system, ultimately resulting in a decrease in the loading accuracy of the system. Independent load port control is a new valve group control technology that can independently adjust the throttling areas of the inlet and outlet valves. This paper focuses on the collaborative control and nonlinear control strategy for managing the two chamber pressures in an independent load port hydraulic system. In this study, represents the control signal of the left chamber servo valve, while represents the control signal of the right chamber servo valve. Additionally,denotes the system pressure, indicates the pressure in the left chamber of the hydraulic cylinder, and signifies the pressure in the right chamber of the hydraulic cylinder. Independent load port electro-hydraulic load simulation system. This article assumes that the extension direction of the piston rod in the hydraulic cylinder is considered as positive, with the two chambers of the hydraulic cylinder being connected to separate servo valves. The pressure control of the independent load port electro-hydraulic load simulation system is achieved through these two servo valves. The independent load port electro-hydraulic load simulation system experiences complex working conditions with multiple modes and variable structures as the pressure of the hydraulic cylinder changes. The analysis focuses on three operating conditions of the left chamber pressure of the hydraulic cylinder. When the system pressureexceeds the pressureof the left chamber of the hydraulic cylinder, the system is considered to be in a normal working state. When the spool of the servo valve is opened in the forward direction and the system pressureis lower than the pressureof the left chamber of the hydraulic cylinder, the oil in the left chamber will be forced out through the oil inlet of the servo valve, resulting in pressure release. When the piston rod of the hydraulic cylinder is impacted by a strong external force, the pressure p1 in the left chamber of the hydraulic cylinder quickly exceeds the system pressure ps. As a result, the spool of the servo valve opens in reverse, allowing the oil in the left chamber of the hydraulic cylinder to flow back into the tank. The mode working conditions of the right chamber of the hydraulic cylinder are similar to the three working conditions of the left chamber. A nonlinear mathematical model of the system is established based on the working principle of the multi-mode variable structure of the independent load port electro-hydraulic load simulation system. Formula (1) represents the flow equation of servo valve 1 under the condition that the system pressure exceeds the pressure in the left chamberwhile the valve core of the left cavity servo valve is opening in the forward direction. When the valve core of the right cavity servo valve opens in the forward direction, the system pressureis higher than the right cavity pressure. This results in the flow equation of servo valve 2. Formula (2) represents the flow equation of servo valve 1 in the scenario where the pressurein the left chamber of the hydraulic cylinder surpasses the oil source pressure, while the spool of servo valve 1 is open in the forward direction. When the servo valve 2 spool opens in the forward direction, the pressurein the right chamber of the hydraulic cylinder exceeds the oil source pressure. This leads to the flow equation of servo valve 2. Formula (3) represents the flow equation of servo valve 1 when the valve core of servo valve 1 is opened in the reverse direction and the pressurein the left chamber exceeds the return oil back pressure. When the valve core of servo valve 2 is opened in the reverse direction, the pressurein the right chamber exceeds the return oil back pressure of servo valve 2. In the formula, and are the volume flow rate entering the cavity, is the valve port flow coefficient, is the slide valve opening area gradient, is the system pressure, is the oil density, is the pressure of the left chamber, is the pressure in the right cavity. In the case of a symmetrical hydraulic cylinder with equal original volumes in the two chambers, and neglecting internal leakage, the flow continuity equation for the two pressure chambers is: In the formula, is the displacement of the hydraulic cylinder piston rod, is the effective area of the hydraulic cylinder piston rod, is the total control volume including the left chamber and pipeline, is the total control volume including the right cavity and pipeline, is the liquid volume elastic modulus of the hydraulic fluid, is the external leakage coefficient of the hydraulic cylinder. Assume the system state variables are and , control volume , , according to formulas (1)–(5), The state Eq. (5) of the left chamber pressure and the state Eq. (6) of the right chamber pressure of the system can be obtained, as follows: Controller design Figure 2 illustrates the system block diagram of the integral sliding mode active disturbance rejection composite control strategy, which is based on fixed-time convergence. The system block diagram is primarily divided into two components: the valve control for the left chamber and the valve control for the right chamber of the independent load port electro-hydraulic load simulation system. The controllers for the left and right chambers of the hydraulic cylinder mainly consist of a fixed-time integral sliding mode controller and an expansion state observer. Block diagram of fixed time integral sliding mode active disturbance rejection composite control. Design controllers for the pressures of the left and right chambers of the independent load port electro-hydraulic load simulation system, corresponding to pressuresand. Once formulas (5) and (6) have been organized, the state equation of the independent load port electro-hydraulic load simulation system can be expressed as follows: In the formula,andare the output quantities of the system state variables, andare the state variables of the system, and are items that have nothing to do with the control quantity,andare the control inputs of the system, and are control compensation factors. It can be known from the state Eqs. (5) and (6) of the valve-controlled independent load port electro-hydraulic load simulation system thatand are respectively. It can be seen that it contains motion disturbances and some parameters that may be uncertain. Under different working conditions and can be written in the following form: Among them, control items and , because and are variables, There are certain changes, so the changes in and can be regarded as disturbances, the fixed parts in and are regarded as and , obviously the values of and are not unique. In the formula, and are the uncertainties of the input gain. The tracking errors of the left chamber pressure and the right chamber pressure of the independent load port electro-hydraulic load simulation system are defined as: Among them, and are the expected pressures of the left cavity and the right cavity respectively. For the independent load port electro-hydraulic load simulation system, the pressure integral sliding surface of the left cavity and right cavity is defined as: In the formula, , , , are the design gain, , , , . The first-order differentials of the pressure integral sliding mode surfaces of the left cavity and the right cavity are respectively: Select the fixed time exponential approaching law as: In the formula, , , , , , , , , , . Connecting Eqs. (19), (21) and Eqs. (20), (22), the pressure control rates of the left and right chambers of the system can be obtained as: In the formula, and are observed and estimated by the expanded state observers (27) and (28). The expanded state system equations of the system state Eqs. (7) and (8) can be written as: An expanded state observer of the following form is used. In the formula,is the observed value of.is the observed value of. ,,and are the appropriate parameter. andare the pressure error value of the two chambers of the hydraulic cylinder. andare the interval length of the linear segment. andare the real numbers from 0 to 1. andare continuous power functions with linear segments as shown in Eqs. (29) and (30) to avoid high-frequency tremors. The observation error of the extended state observer may lead to stability issues in the inner loop of active disturbance rejection control, influencing the acceptable value range for parameters and . When the values of and are too small, the inner loop of the active disturbance rejection control may diverge because of the excessive equivalent open-loop gain. When the values of and are too large, it can result in significant control errors. This paper considers the constant parts and of and as indicated in Eq. (31), and substitutes them with constants for the simulation process. Before conducting the performance analysis of the fixed-time convergent integral sliding mode active disturbance rejection controller, it is necessary to first introduce the following lemma: Lemma 1 For a class of nonlinear systems. Among them, it is assumed that there is a Lyapunov function that satisfies: Among them, if the parameter values satisfy , , , and , the system is said to be globally fixed-time stable33, and the convergence time T is bounded, and the convergence time satisfies the inequality (34): In order to prove that the integral sliding mode surfaces and can converge to zero within a fixed time, the following Lyapunov function is selected: Derive the Eqs. (35) and (36) and sort them out: Substituting the designed control rates (23) and (24) into Eqs. (37) and (38) respectively, the above equation can be continued to be organized as: Equations (39) and (40) are always less than or equal to 0. Based on Lemma 1, the designed fixed-time convergent integral sliding mode surfaces and meet the reachability condition, ensuring that the fixed-time Eqs. (41) and (42) are asymptotically stable. The convergence of the tracking error of the system state is proven by analyzing Eqs. (41) and (42), which demonstrate that the integral sliding mode variable converges within a fixed time. Stability of the integral sliding mode variable leads to the acquisition of and . Select the following Lyapunov function: By deriving the derivatives of Eqs. (45) and (46) and sorting them out, we can get: Equations (47) and (48) demonstrate that they are always less than or equal to 0. As per Lemma 1, it is evident that the tracking error of the system converges at a specific time, indicating that (49) and (50) are asymptotically stable at a fixed time. Simulation results and analysis Closed-loop pressure simulation analysis The closed-loop independent load port electro-hydraulic load simulation system is assumed to experience sinusoidal motion as an external position disturbance. In the simulation, the position disturbance signal is denoted as (m), with an amplitude of 10 mm and a frequency range of 1–5 Hz. A comparative simulation study was conducted on fixed-time integral sliding mode active disturbance rejection control, PID, and active disturbance rejection control strategies for an independent load port electro-hydraulic load simulation system under sinusoidal motion disturbance. The system command pressure signals are designated as and , respectively. The pressure control target for the left chamber of the hydraulic cylinder is set at 10,000 kPa, while the target for the right chamber is set at 5,000 kPa. The controller parameters for both the left and right chambers of the hydraulic cylinder are identical; thus, only a single set of system and simulation parameters is presented in Tables 1 and 2. The figure below displays the closed-loop output pressure and pressure error of the system. Table 1System parameters.NameNumerical valueServo valve flow coefficient Effective area of hydraulic cylinder piston rod External leakage coefficient Liquid volume elastic modulus of hydraulic fluids Density of hydraulic fluid Hydraulic cylinder stroke Maximum valve flowSystem pressure System parameters. Maximum valve flow System pressure Table 2Simulation parameters.FISMADRCPIDADRC 0.05 3.52e7P18 3.52e7 1 10e3I25 500 1 10e7D1 10e6 0.5 0.001 0.001 10e3 0.9 0.5 22 1 22 1.5 Simulation parameters. The primary parameters in the expanded state observer of the active disturbance rejection controller are denoted as and . When parameter is excessively large, it can induce system oscillations and divergence, ultimately resulting in system instability. Conversely, if parameter is reduced to a certain threshold, it may also lead to similar oscillations and divergence. Typically, in such scenarios, it is customary to set parameter to approximately . When the value of increases, the system output exhibits oscillatory behavior. Conversely, when the value of decreases, the response speed of the system slows down, resulting in a smoother transition process. Typically, the value of is set at , and the integration step discussed in this article is denoted as . In the design of a fixed-time convergence integral sliding mode active disturbance rejection composite controller, the parameters of the extended state observer are selected with reference to the active disturbance rejection controller. Parameters and are critical indicators of convergence. Specifically, and facilitate rapid convergence of the system when it is distant from the equilibrium point. Conversely, and promote slower convergence when the system is near the equilibrium point, thereby minimizing the incidence of control system issues, such as the chattering phenomenon. Among these, the values of , , g, and should be positive constants that can adjust the speed of convergence to the equilibrium point; larger values result in faster convergence. The variable represents a constant-velocity approach term. To ensure a rapid approach while minimizing chattering, the value of should be selected judiciously. The parameters of the PID controller primarily rely on empirical methods. Typically, the I and D components are initially disregarded. First, the P parameter is set to a small value for trial control, and the system’s response is observed. Based on the characteristics of the actual system, the P parameter is gradually increased until the system begins to diverge or exhibit significant oscillations, thereby identifying the critical value of the P parameter. Subsequently, the I parameter is adjusted according to the steady-state error of the system to facilitate the rapid elimination of this error. Finally, the D parameter is tuned based on the system’s dynamic pressure response to optimize overshoot and response speed. The closed-loop pressure curve presented in Fig. 3, along with the closed-loop pressure error curve in Fig. 4, illustrates that when the frequency of the disturbance signal is set to 1 Hz, the application of composite control through fixed-time integral sliding mode auto-disturbance rejection results in a rise time of approximately 0.015 s for the pressure to reach the steady-state value. Although the pressure exhibits slight fluctuations prior to stabilizing, it does not experience any overshoot and transitions smoothly to the steady-state pressure. Once in the steady state, the pressure closely aligns with the command pressure curve. The steady-state pressure overshoot is minimal, with a stable pressure error of approximately 6 kPa, resulting in a pressure control accuracy of 99.88%. Under active disturbance rejection control, the rise time for the pressure to reach the steady-state value is approximately 0.05 s. Initially, there is a fluctuation before the pressure stabilizes, followed by a smooth transition to the steady-state pressure. Once the steady-state is achieved, the pressure overshoot is around 14.2 kPa, while maintaining high accuracy, with the pressure control accuracy measured at approximately 99.71%. Under PID control, the rise time for the pressure to reach steady-state is approximately 0.045 s. The pressure experiences fluctuations until it stabilizes at the steady-state value. Once steady-state is achieved, the maximum pressure overshoot is recorded at 150 kPa, with a pressure control accuracy of approximately 97%. Closed-loop pressure when disturbance frequency is 1 Hz. Closed-loop pressure error when the disturbance frequency is 1 Hz. The closed-loop pressure curve presented in Fig. 5, along with the closed-loop pressure error curve in Fig. 6, indicates that when the disturbance signal frequency is set at 3 Hz, the composite control strategy employing fixed-time integrated sliding mode auto-disturbance rejection results in a rise time of approximately 0.015 s for the pressure to reach its steady-state value. Although the pressure exhibits some fluctuations before attaining the steady-state, it transitions smoothly without any overshoot. Subsequently, the pressure stabilizes and closely aligns with the command pressure curve. The overshoot in steady-state pressure is minimal, with a steady-state error of approximately 7 kPa, resulting in a pressure control accuracy of 99.86%. Closed-loop pressure when disturbance frequency is 3 Hz. Closed-loop pressure error when the disturbance frequency is 3 Hz. Under automatic disturbance rejection control, the rise time for the pressure to reach the steady-state value is approximately 0.05 s. There is an initial fluctuation before the pressure stabilizes, transitioning to the steady-state value without any overshoot. Once in the steady state, the pressure experiences an overshoot of approximately 60 kPa, while maintaining high accuracy. The overall pressure control accuracy is about 98.8%. Under PID control, the rise time for the pressure to reach the steady-state value is approximately 0.045 s. The pressure experiences fluctuations until it stabilizes at the steady-state level. Once the steady-state pressure is achieved, the maximum pressure overshoot recorded is 155 kPa, and the pressure control accuracy is approximately 96.9%. The closed-loop pressure curve presented in Fig. 7 and the closed-loop pressure error curve in Fig. 8 indicate that when the frequency of the disturbance signal is set to 5 Hz, the rise time for the pressure to reach the steady-state value, under the composite control of fixed-time integrated sliding mode auto-disturbance rejection, is approximately 0.018 s. During this period, the pressure exhibits minimal fluctuation before stabilizing, transitioning smoothly to the steady-state pressure without any overshoot. Once the steady-state pressure is attained, it closely aligns with the command pressure curve. The overshoot in steady-state pressure is negligible, resulting in a steady-state error of approximately 8.2 kPa, which corresponds to a pressure control accuracy of 99.83%. Under active disturbance rejection control, the rise time for the pressure to reach the steady-state value is approximately 0.05 s. There is a fluctuation observed prior to the pressure achieving steady-state, followed by a smooth transition to this state. Once steady-state is reached, the pressure overshoot is approximately 68.1 kPa, while maintaining high accuracy, with the pressure control accuracy measured at around 98.64%. Under PID control, the rise time for the pressure to reach steady-state is approximately 0.045 s. Notably, the pressure is consistently accompanied by vibrations during the transition to steady-state. Upon achieving steady-state pressure, the maximum pressure overshoot recorded is 182 kPa, with a pressure control accuracy of approximately 96.36%. Closed-loop pressure when disturbance frequency is 5 Hz. Closed-loop pressure error when the disturbance frequency is 5 Hz. The results depicted in Fig. 9 demonstrate that with a disturbance signal frequency of 1 Hz and utilizing fixed-time integral sliding mode active disturbance rejection control, the closed-loop pressure curve exhibits rapid response and excellent dynamic tracking performance, the closed-loop pressure tracks the upper command pressure at approximately 0.011s. The pressure curve effectively follows the sinusoidal pattern, including peaks and troughs, with smooth and stable transitions, devoid of any buffeting. The closed-loop pressure error curve in Fig. 10 reveals that the initial pressure error fluctuation is 150 kPa, with a maximum overshoot of approximately 6 kPa after reaching steady state. The pressure control accuracy is measured at 99.88%. Under active disturbance rejection control, the pressure responds quickly, the closed-loop pressure tracks the upper command pressure at approximately 0.015s. However, there is a certain tracking error at the peaks and troughs of the sinusoidal pressure curve. Analyzing the closed-loop pressure error curve in Fig. 10 reveals that the pressure error fluctuation at the beginning is 187 kPa. As the system reaches steady state, the maximum overshoot of the rear pressure is approximately 18.6 kPa, resulting in a pressure control accuracy of 99.62%. Under PID control, the closed-loop pressure curve exhibits a slight delay in response, there is a certain delay in the pressure curve tracking, and the closed-loop pressure tracks the command pressure at about 0.06s. Due to the lack of filtering effect in PID control, noise significantly affects the pressure curve, particularly at its peaks and troughs. As shown in Fig. 10, the initial pressure error fluctuation is 475 kPa, with a maximum overshoot of approximately 171.3 kPa after reaching steady state. The pressure control accuracy is measured at 96.57%. Closed-loop pressure when disturbance frequency is 1 Hz. Closed-loop pressure error when the disturbance frequency is 1 Hz. As illustrated in Fig. 11, with a disturbance signal frequency of 3 Hz, the closed-loop pressure curve exhibits rapid response under the fixed-time integral sliding mode active disturbance rejection control, achieving the command pressure in approximately 0.015s. The dynamic tracking performance of the closed-loop pressure is commendable, with effective tracking at both peaks and troughs of the pressure curve. Moreover, the transition of the pressure curve is smooth and stable, devoid of any buffeting. The closed-loop pressure error curve in Fig. 12 illustrates that the pressure error fluctuation at the beginning is 390 kPa, with a maximum overshoot of approximately 7 kPa after reaching steady state. The pressure control accuracy is calculated to be 99.86%. Under active disturbance rejection control, the pressure responds rapidly and achieves the desired pressure in approximately 0.02s. However, during the peaks and troughs of the sinusoidal pressure curve, there is a noticeable tracking error in the pressure curve. The closed-loop pressure error curve in Fig. 12 illustrates that the initial pressure error fluctuation is 261 kPa, with a maximum overshoot of approximately 35.3 kPa after reaching steady state. The pressure control accuracy is measured at 99.29%. Under PID control, the closed-loop pressure curve exhibits a slight delay in response, the pressure curve tracks the upper command pressure at 0.05s. Due to the lack of filtering effect in PID control, noise significantly impacts the pressure curve, particularly at its peaks and troughs. Analysis in Fig. 12 reveals an initial pressure error fluctuation of 500 kPa, a maximum overshoot of approximately 184.2 kPa after reaching steady state, and a pressure control accuracy of 96.31%. Closed-loop pressure when disturbance frequency is 3 Hz. Closed-loop pressure error when the disturbance frequency is 3 Hz. As illustrated in Fig. 13, when the disturbance signal frequency is 5 Hz, the closed-loop pressure curve exhibits rapid response under the fixed-time integral sliding mode active disturbance rejection control, achieving the command pressure in approximately 0.015s. The closed-loop pressure demonstrates excellent dynamic tracking performance, effectively following the sinusoidal peaks and troughs with smooth transitions and stability, devoid of any buffeting. The closed-loop pressure error curve in Fig. 14 demonstrates that the initial pressure error fluctuation is 328 kPa, with a maximum overshoot of approximately 8 kPa upon reaching steady state. The pressure control accuracy is calculated to be 99.84%. Under active disturbance rejection control, the pressure responds rapidly and achieves the desired pressure in approximately 0.02s. Nonetheless, there is a noticeable tracking error at the peaks and troughs of the sinusoidal pressure curve. Analysis of the closed-loop pressure error curve in Fig. 14 reveals an initial pressure error fluctuation of 375 kPa, a maximum overshoot of approximately 75 kPa after reaching steady state, and a pressure control accuracy of 98.5%. Under PID control, the closed-loop pressure curve exhibits a slightly slow response, the pressure curve tracks the upper command pressure at 0.06s. Due to the lack of filtering in PID control, noise significantly affects the pressure curve, particularly at its peaks and troughs. Analysis of Fig. 14 reveals an initial pressure error fluctuation of 670 kPa, a maximum overshoot of approximately 195.2 kPa after reaching steady state, and a pressure control accuracy of 96.09%. Closed-loop pressure error when the disturbance frequency is 5 Hz. Closed-loop pressure error when the disturbance frequency is 5 Hz. The analysis presented in Figs. 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13 and 14 demonstrates that, when subjected to step and sinusoidal command pressures within a closed-loop system, the fixed-time integral sliding mode active disturbance rejection composite control exhibits lower pressure levels compared to both active disturbance rejection and PID control, particularly under varying disturbance signal frequencies. Additionally, this control method achieves a faster rise time for steady-state pressure, minimal overshoot of the steady-state error, and enhanced pressure control accuracy. These results indicate that the fixed-time integral sliding mode active disturbance rejection composite control provides superior control performance and robustness. Based on the comparative analysis presented, it is evident that fixed-time convergence integral sliding mode active disturbance rejection control exhibits a faster pressure response time and superior control accuracy compared to both active disturbance rejection and PID control. As illustrated in the figure above, the pressure curve of PID control exhibits greater fluctuations and lacks smoothness when compared to the active disturbance rejection and fixed time convergence integral sliding mode automatic disturbance rejection control methods. It can be observed from formulas (1)-(3) that, during the operational mode of the multi-mode variable structure of the independent load port electro-hydraulic load simulation system, the servo valve exhibits commutation characteristics. Additionally, the presence of noise-inducing factors can lead to fluctuations in the pressure curve associated with PID control. It can be observed from formulas (1)-(3) that, during the operational mode of the multi-mode variable structure of the independent load port electro-hydraulic load simulation system, the servo valve exhibits commutation characteristics. Additionally, the presence of noise-inducing factors can lead to fluctuations in the pressure curve associated with PID control. However, the expanded state observer exhibits a filtering effect, resulting in a smoother pressure curve for both the Active Disturbance Rejection Control (ADRC) and the fixed-time convergence integral sliding mode ADRC. This demonstrates that the closed-loop pressure of the independent load port electro-hydraulic load simulation system exhibits strong anti-interference and anti-noise capabilities. Energy saving simulation analysis The conventional valve-controlled electro-hydraulic load simulation system utilizes a valve core to regulate both the inlet and outlet oil circuits of the hydraulic cylinder. This system throttles both the inlet and outlet during the process of inlet throttling and speed regulation, leading to high energy consumption and low efficiency. To address the inefficiency of traditional valve-controlled hydraulic systems, this article proposes a solution in which two servo valves regulate the pressure in the respective chambers of an independent load port hydraulic system during loading. Upon reaching the command pressure , the pressure in the left chamber of the hydraulic cylinder is measured at 10,000 kPa, while the pressure in the right chamber is 5000 kPa. To reduce the energy consumption of the system and enhance the energy-saving characteristics of the hydraulic system, the pressure in both chambers of the hydraulic cylinder is maintained at the lowest possible level. The pressures in the left chamber of the hydraulic cylinder are set to 5500 kPa and 5200 kPa, respectively, while the pressures in the right chamber are set to 500 kPa and 200 kPa, respectively. This configuration reduces the supply pressure of the system, thereby minimizing power and energy consumption. As illustrated in Fig. 15, the fixed-time convergence integral sliding mode active disturbance rejection control results in the left chamber of the hydraulic cylinder reaching a pressure of 10,000 kPa, while the right chamber reaches 5000 kPa. Both chambers achieve the specified pressure within approximately 0.015s. Consequently, the output pressure of the hydraulic cylinder stabilizes at 5000 kPa without any overshoot or fluctuation once the left and right chambers reach a steady state. System closed loop pressure. Under fixed-time convergence integral sliding mode active disturbance rejection control, the pressure in the left chamber of the hydraulic cylinder is 5500 kPa, while the pressure in the right chamber is 500 kPa, as illustrated in Fig. 16. It takes approximately 0.015s for the pressures in both chambers to reach the specified pressure. The output pressure of the hydraulic cylinder stabilizes at 5000 kPa, with fluctuations in the two chambers before reaching this level. Currently, the supply pressure of the hydraulic cylinder system decreased from 10,000 kPa to 5,500 kPa, resulting in a reduction of the system’s input power from to . It is evident that the flow rate remains constant, and an energy saving of approximately 45% can be realized compared to the original system. The closed-loop pressure in the right chamber of the hydraulic cylinder is 500 kPa. As depicted in Fig. 17, in the context of fixed-time convergence integral sliding mode active disturbance rejection control, the pressure in the left chamber of the hydraulic cylinder measures 5200 kPa, while in the right chamber it stands at 200 kPa. The output pressure of the hydraulic cylinder is recorded at 5000 kPa, with both chambers reaching the specified pressure of about 0.015s. Prior to attaining the set pressure, there is a certain degree of pressure fluctuation. The closed-loop pressure in the right chamber of the hydraulic cylinder is 200 kPa. Currently, the supply pressure of the hydraulic cylinder system has decreased from 10,000 kPa to 5,200 kPa, resulting in a reduction of the system’s input power from to . Notably, the flow rate remains constant, indicating that an energy savings of approximately 48% can be realized compared to the original system. Conclusions This paper presents a multi-mode variable structure independent load port electro-hydraulic load simulation system designed to mitigate external motion disturbances encountered by the electro-hydraulic load simulation system. The nonlinear mathematical model of the system was used to establish its state equation, from which an integral sliding mode active disturbance rejection composite controller with fixed time convergence was derived. Simulation tests were conducted to validate the proposed controller, yielding the following results. The independent load port electro-hydraulic load simulation system proposed in this article integrates independent load port control technology with the electro-hydraulic load simulator. In addressing the complex working conditions of the multi-mode variable structure within the independent load port electro-hydraulic load simulation system, the flow formulas for the inlet and outlet valves were re-derived. The simulation results indicate that the independent load port electro-hydraulic load simulation system demonstrates a high degree of control freedom, rapid pressure response, exceptional control accuracy, robust anti-disturbance capabilities, and flexible, convenient control. These findings suggest that independent load port technology is well-suited for loading pressure control in electro-hydraulic load simulation systems, which holds significant implications for practical engineering applications of the load simulator. The independent load port electro-hydraulic load simulation system proposed in this article integrates independent load port control technology with the electro-hydraulic load simulator. In addressing the complex working conditions of the multi-mode variable structure within the independent load port electro-hydraulic load simulation system, the flow formulas for the inlet and outlet valves were re-derived. The simulation results indicate that the independent load port electro-hydraulic load simulation system demonstrates a high degree of control freedom, rapid pressure response, exceptional control accuracy, robust anti-disturbance capabilities, and flexible, convenient control. These findings suggest that independent load port technology is well-suited for loading pressure control in electro-hydraulic load simulation systems, which holds significant implications for practical engineering applications of the load simulator. The simulation test results indicate that, under the influence of a sinusoidal disturbance signal with an amplitude of 10 mm and a frequency of 5 Hz, the independent load port electro-hydraulic load simulation system still shows high pressure loading accuracy and strong anti-interference ability. This finding demonstrates the effectiveness of the fixed-time convergence of the integral sliding mode auto-disturbance immunity composite control. Additionally, the high anti-disturbance limit performance threshold of the independent load port electro-hydraulic load simulation system’s closed-loop pressure further supports the suitability of this control strategy for the loading applications of the independent load port electro-hydraulic load simulation system, thereby enhancing its pressure control performance. The simulation test results indicate that, under the influence of a sinusoidal disturbance signal with an amplitude of 10 mm and a frequency of 5 Hz, the independent load port electro-hydraulic load simulation system still shows high pressure loading accuracy and strong anti-interference ability. This finding demonstrates the effectiveness of the fixed-time convergence of the integral sliding mode auto-disturbance immunity composite control. Additionally, the high anti-disturbance limit performance threshold of the independent load port electro-hydraulic load simulation system’s closed-loop pressure further supports the suitability of this control strategy for the loading applications of the independent load port electro-hydraulic load simulation system, thereby enhancing its pressure control performance. This study investigates the energy-saving features of an independent load port electro-hydraulic load simulation system through simulation and analysis. The results demonstrate that by maintaining low pressure in the back pressure chamber of the hydraulic cylinder, the supply pressure of the electro-hydraulic load simulation system can be notably decreased, thereby reducing the total energy consumption of the system. These findings confirm the superior energy-saving performance of the independent load port electro-hydraulic load simulation system, emphasizing its practicality and advantages in load simulator pressure control. This study investigates the energy-saving features of an independent load port electro-hydraulic load simulation system through simulation and analysis. The results demonstrate that by maintaining low pressure in the back pressure chamber of the hydraulic cylinder, the supply pressure of the electro-hydraulic load simulation system can be notably decreased, thereby reducing the total energy consumption of the system. These findings confirm the superior energy-saving performance of the independent load port electro-hydraulic load simulation system, emphasizing its practicality and advantages in load simulator pressure control. Overall, the integrated sliding mode active disturbance rejection composite control strategy, along with the independent load port control technology proposed in this article, demonstrates significant potential for enhancing the pressure control effectiveness of the hydraulic system within the electro-hydraulic load simulation framework. This valve-controlled electro-hydraulic load simulation system, particularly its hydraulic cylinder configuration, represents a research direction of considerable application value. Regardless of whether the direction of movement of the steering gear changes, the pressure control of the independent load port electro-hydraulic load simulation system examined in this article maintains a constant pressure output. Under certain specific working conditions, a sudden change in the movement mode of the steering gear can lead to a mismatch between the electro-hydraulic load simulation system and the steering gear system. This mismatch may result in pressure shock issues. Furthermore, there is potential for enhancing the mode-switching control strategy of the controller, which requires in-depth research. The electro-hydraulic servo system presents numerous nonlinear challenges. Future research should address the nonlinear friction characteristics of the hydraulic cylinder, as well as the identification algorithms necessary for managing uncertain nonlinearities. Author contributions Author Contributions: H.H. and H.Y. conceived and designed the study. H.H. performed the controller design, carried out simulations and wrote the original draft. H.Y. reviewed and edited the manuscript. All authors read and approved the manuscript. All authors have read and agreed to the published version of the manuscript. Data availability All data generated or analysed during this study are included in this published article. Declarations Competing interests The authors declare no competing interests. Footnotes Publisher’s note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations. References Associated Data Data Availability Statement All data generated or analysed during this study are included in this published article.