Eur. Phys. J. C (2014) 74:3071 DOI 10.1140/epjc/s10052-014-3071-4 Regular Article - Experimental Physics Electron and photon energy calibration with the ATLAS detector using LHC Run 1 data The ATLAS Collaboration CERN, 1211 Geneva 23, Switzerland Received: 21 July 2014 / Accepted: 10 September 2014 / Published online: 1 October 2014 © CERN for the benefit of the ATLAS collaboration 2014. This article is published with open access at Springerlink.com Abstract This paper presents the electron and photon energy calibration achieved with the ATLAS detector using about 25 fb−1 of LHC proton–proton collision data taken at √ centre-of-mass energies of s = 7 and 8 TeV. The reconstruction of electron and photon energies is optimised using multivariate algorithms. The response of the calorimeter layers is equalised in data and simulation, and the longitudinal profile of the electromagnetic showers is exploited to estimate the passive material in front of the calorimeter and reoptimise the detector simulation. After all corrections, the Z resonance is used to set the absolute energy scale. For electrons from Z decays, the achieved calibration is typically accurate to 0.05 % in most of the detector acceptance, rising to 0.2 % in regions with large amounts of passive material. The remaining inaccuracy is less than 0.2–1 % for electrons with a transverse energy of 10 GeV, and is on average 0.3 % for photons. The detector resolution is determined with a relative inaccuracy of less than 10 % for electrons and photons up to 60 GeV transverse energy, rising to 40 % for transverse energies above 500 GeV. 1 Introduction Precise calibration of the energy measurement of electrons and photons is a fundamental input to many physics measurements. In particular, after the discovery of the Higgs boson by the ATLAS and CMS experiments [1,2], an accurate determination of its properties is of primary importance. A precise measurement of the W boson mass is also a long-term goal of the LHC experiments, and requires an excellent accuracy of the electron energy calibration. A first electron and photon calibration analysis was performed using 40 pb−1 of LHC collision data taken in 2010 √ at a centre-of-mass energy s = 7 TeV [3]. The calibration of the ATLAS liquid argon (LAr) calorimeter was primarily based on test-beam measurements; only the absolute energy  e-mail: atlas.publications@cern.ch scale was set using the Z boson resonance. The uncertainty on the detector material upstream of the LAr calorimeter, which is of primary importance in understanding its response to incident electromagnetic particles, was estimated from engineering drawings and a material survey during construction. The achieved calibration was accurate to 0.5–1 % for electrons, depending on pseudorapidity and energy. This paper presents the calibration scheme developed for precision measurements involving electrons and photons with |η| < 2.471 and mostly derived from collision data. It comprises local corrections to the calorimeter energy measurement, and the intercalibration of its longitudinal layers; a measurement of detector material leading to an improved simulation; an improved simulation-based calibration; and a measurement of the absolute energy scale from Z boson decays. The universality of the energy scale is verified using J/ψ → ee and Z → γ decays ( = e, μ). The studies are primarily based on 20.3 fb−1 of proton–proton collision √ data collected in 2012 at s = 8 TeV, and the algorithms are √ tested on 4.5 fb−1 of data collected in 2011 at s = 7 TeV. The paper is organised as follows. After an overview of the energy reconstruction with the ATLAS LAr calorimeter in Sect. 2, the calibration procedure, the data and simulated Monte Carlo (MC) samples used for this purpose are summarised in Sects. 3 and 4. Section 5 describes the simulationbased energy calibration algorithm. Data-driven corrections to the energy measurement and to the detector material budget are presented in Sects. 6 to 8, and the absolute energy scale determination from Z boson decays is described in Sect. 9. Systematic uncertainties affecting the calibration and crosschecks of the Z -based energy scale are given in Sects. 10–13. The results of this calibration procedure applied to the 2011 1 ATLAS uses a right-handed coordinate system with its origin at the nominal interaction point (IP) in the centre of the detector and the z-axis along the beam pipe. The x-axis points from the IP to the centre of the LHC ring, and the y-axis points upward. Cylindrical coordinates (r, φ) are used in the transverse plane, φ being the azimuthal angle around the beam pipe. The pseudorapidity is defined in terms of the polar angle θ as η = − ln tan(θ/2). 123 3071 Page 2 of 48 data sample are summarised in Appendix A. Uncertainties on the energy resolution are discussed in Sect. 14, and the performance of an algorithm combining the calorimeter energy measurement with the momentum measured in the tracking detectors is presented in Sect. 15. Section 16 summarises the achieved results and concludes the paper. 2 Electron and photon reconstruction and identification in ATLAS 2.1 The ATLAS detector The ATLAS experiment [4] is a general-purpose particle physics detector with a forward-backward symmetric cylindrical geometry and near 4π coverage in solid angle. The inner tracking detector (ID) covers the pseudorapidity range |η| < 2.5 and consists of a silicon pixel detector, a silicon microstrip detector (SCT), and a transition radiation tracker (TRT) in the range |η| < 2.0. The ID is surrounded by a superconducting solenoid providing a 2 T magnetic field. The ID provides accurate reconstruction of tracks from the primary proton–proton collision region and also identifies tracks from secondary vertices, permitting an efficient reconstruction of photon conversions in the ID up to a radius of about 800 mm. The electromagnetic (EM) calorimeter is a LAr sampling calorimeter with an accordion geometry. It is divided into a barrel section (EMB), covering the pseudorapidity region |η| < 1.475,2 and two endcap sections (EMEC), covering 1.375 < |η| < 3.2. The barrel and endcap sections are divided into 16 and 8 modules in φ, respectively. The transition region between the EMB and the EMEC, 1.37 < |η| < 1.52, has a large amount of material in front of the first active calorimeter layer ranging from 5 to almost 10 radiation lengths (X 0 ). A high voltage (HV) system generates an electric field of about 1 kV/mm, which allows ionisation electrons to drift in the LAr gap. In the EMB, the HV is constant along η, while in the EMEC, where the gap varies continuously with radius, it is adjusted in steps along η. The HV supply granularity is typically in sectors of η × φ = 0.2 × 0.2. Both the barrel and endcap calorimeters are longitudinally segmented into three shower-depth layers for |η| < 2.5. The first one (L1), in the ranges |η| < 1.4 and 1.5 < |η| < 2.4, has a thickness of about 4.4X 0 and is segmented into highgranularity strips in the η direction, typically 0.003 × 0.1 in η × φ in EMB, sufficient to provide an event-by-event discrimination between single photon showers and two overlapping showers coming from the decay of neutral hadrons in jets [5]. The second layer (L2), which collects most of the 2 The EMB is split into two half-barrel modules which cover the posi- tive and negative η regions. 123 Eur. Phys. J. C (2014) 74:3071 energy deposited in the calorimeter by photon and electron showers, has a thickness of about 17X 0 and a granularity of 0.025 × 0.025 in η × φ. A third layer (L3), which has a granularity of 0.05 × 0.025 in η × φ and a depth of about 2X 0 , is used to correct leakage beyond the EM calorimeter for high-energy showers. In front of the accordion calorimeter, a thin presampler layer (PS), covering the pseudorapidity interval |η| < 1.8, is used to correct for energy loss upstream of the calorimeter. The PS consists of an active LAr layer with a thickness of 1.1 cm (0.5 cm) in the barrel (endcap) and has a granularity of η × φ = 0.025 × 0.1. The hadronic calorimeter, surrounding the EM calorimeter, consists of an iron/scintillator tile calorimeter in the range |η| < 1.7 and two copper/LAr calorimeters spanning 1.5 < |η| < 3.2. The acceptance is extended by two copper/LAr and tungsten/LAr forward calorimeters up to |η| = 4.9. The forward calorimeters also provide electron reconstruction capability, a feature that is not discussed here. The muon spectrometer, located beyond the calorimeters, consists of three large air-core superconducting toroid systems with precision tracking chambers providing accurate muon tracking for |η| < 2.7 and fast detectors for triggering for |η| < 2.4. 2.2 Energy reconstruction in the electromagnetic calorimeter Electrons and photons entering the LAr calorimeter develop EM showers through their interaction with the lead absorbers. The EM showers ionise the LAr in the gaps between the absorbers. The ionisation electrons drift and induce an electrical signal on the electrodes which is proportional to the energy deposited in the active volume of the calorimeter. The signal is brought via cables to the read-out Front End Boards, where it is first amplified by a current-sensitive pre-amplifier. In order to accommodate a large dynamic range, and to optimise the total noise due to electronics and inelastic pp collisions coming from previous bunch crossings (out-of-time pile-up), the signal is shaped by a bipolar filter and simultaneously amplified with three linear gains called low (LG), medium (MG) and high (HG). For each channel, these three amplified signals are sampled at a 40 MHz clock frequency and stored on a switched capacitor array, awaiting the level1 trigger decision; upon receipt, the sample corresponding to the maximum amplitude of the physical pulse stored in MG is first digitised by a 12-bit analog-to-digital converter (ADC). Based on this sample, a hardware gain selection is used to choose the most suited gain. The samples of the chosen gain are digitised and routed via optical fibres to the read-out drivers. More details on the ATLAS LAr calorimeter read-out and electronic calibration are given in Refs. [6,7]. The total energy deposited in an EM calorimeter cell is reconstructed as Eur. Phys. J. C (2014) 74:3071 Page 3 of 48 3071 E cell = FμA→MeV × FDAC→μA Nsamples  1 × Mphys × G × a j (s j − p), Mcali (1) j=1 where s j are the samples of the shaped ionisation signal digitised in the selected electronic gain, measured in ADC counts in Nsamples time slices (Nsamples = 5) spaced by 25 ns;3 p is the read-out electronic pedestal, measured for each gain in dedicated calibration runs; the a j weights are the optimal filtering coefficients (OFC) derived from the predicted shape of the ionisation pulse and the noise autocorrelation, accounting for both the electronic and the pile-up components [8]. The cell gain G is computed by injecting a known calibration signal and reconstructing the corresponding cell response. The factor Mphys Mcali , which quantifies the ratio of the maxima of the physical and calibration pulses corresponding to the same input current, corrects the gain factor G obtained with the calibration pulses to adapt it to physics-induced signals; the factor FDAC→μA converts digital-to-analog converter (DAC) counts set on the calibration board to a current in μA; the factor FμA→MeV converts the ionisation current to the total deposited energy at the EM scale and is determined from test-beam studies [9]. 2.3 Electron and photon reconstruction The reconstruction of electrons and photons in the region |η| < 2.47 starts from energy deposits (clusters) in the EM calorimeter. To reconstruct the EM clusters, the EM calorimeter is divided into a grid of Nη × Nφ towers of size η × φ = 0.025 × 0.025. Inside each of these elements, the energy of all cells in all longitudinal layers is summed into the tower energy. These clusters are seeded by towers with total transverse energy above 2.5 GeV and searched for by a sliding-window algorithm [10], with a window size of 3 × 5 towers. Clusters matched to a well-reconstructed ID track originating from a vertex found in the beam interaction region are classified as electrons. If the matched track is consistent with originating from a photon conversion and if in addition a conversion vertex is reconstructed, the corresponding candidates are considered as converted photons. They are classified as single-track or double-track conversions depending on the number of assigned electron-tracks. Clusters without matching tracks are classified as unconverted photons [5]. The electron cluster is then rebuilt using an area of calorimeter cells corresponding to 3 × 7 and 5 × 5 L2 cells4 in the 3 The delay between the event trigger and the time slices is optimised to ensure that the third sample is on average at the signal maximum in each read-out channel. 4 Only in L2 does the cell granularity correspond exactly to this tower size: the number of cells selected by the clustering algorithm EMB and EMEC respectively. For converted photons, the same 3 × 7 cluster size is used in the barrel, while a 3 × 5 cluster is associated with unconverted photons due to their smaller lateral size. A 5 × 5 cluster size is used in the EMEC for converted and unconverted photons. These lateral cluster sizes were optimised to take into account the different overall energy distributions in the barrel and endcap calorimeters while minimising the pile-up and noise contributions. The cluster energy is then determined by applying correction factors computed by a calibration scheme based on the full detector simulation, which is described in Sect. 5. Photons and electrons reconstructed near regions of the calorimeter affected by read-out or HV failures are rejected [11]. The relative energy resolution for these EM objects can be parameterised as follows: a b σ = √ ⊕ ⊕ c, E E E (2) where a, b and c are η-dependent parameters; a is the sampling term, b is the noise term, and c is the constant term. The sampling term contributes mostly at low energy; its design √ value is (9–10)%/ E[GeV] at low |η|, and is expected to worsen as the amount of material in front of the calorimeter increases at larger |η|. The noise term is about 350 × cosh η MeV for a 3×7 cluster in η ×φ space in the barrel and for a mean number of interactions per bunch crossing μ = 20; it is dominated by the pile-up noise at high η. At higher energies the relative energy resolution tends asymptotically to the constant term, c, which has a design value of 0.7 %. 2.4 Electron and photon identification The clusters associated with electron and photon candidates must satisfy a set of identification criteria, requiring their longitudinal and transverse profiles to be consistent with those expected for EM showers induced by such particles. Three reference sets of cut-based selections, labelled loose, medium and tight, have been defined for electrons with increasing background rejection power [12,13]. Shower shape variables in both the first and second layers of the EM calorimeter and the fraction of energy deposited in the hadronic calorimeter are used in the loose selection with additional requirements on the associated track quality and trackcluster matching. Tightened requirements on these discriminating variables are added to the medium criteria together with a loose selection on the transverse impact parameter and on the number of hits in the TRT associated with the track, and a measured hit in the innermost layer of the pixel detector to Footnote 4 continued in the other layers varies according to the position of the cluster barycentre in L2 [10]. 123 3071 Page 4 of 48 simulation Eur. Phys. J. C (2014) 74:3071 1 training of 5 Z ee 3 resolution smearing MC-based e/ calibration EM cluster energy calibrated e/ energy MC-based e/ energy calibration data 2 longitudinal layer intercalibration 4 5 uniformity corrections 6 Z ee scale calibration J/ ee Z ll data-driven scale validation Fig. 1 Schematic overview of the procedure used to calibrate the energy response of electrons and photons in ATLAS discriminate against photon conversions.5 The tight selection adds a selection on the ratio of the candidate’s reconstructed energy to its track momentum, E/ p, stricter requirements on the discriminating variables and TRT information, and a veto on reconstructed photon conversion vertices associated with the cluster. The identification of photons is performed by applying cuts on shower shapes measured in the first two longitudinal layers of the EM calorimeter and on the leakage into the hadronic calorimeter [14]. To further suppress background from hadronic decays, an isolation requirement is applied. The calorimeter isolation transverse energy E Tiso is computed by summing the transverse  energy of all calorimeter cells in a cone of size R = ( η)2 + ( φ)2 around the candidate [10]. The isolation energy is corrected by subtracting the estimated contributions from the photon or electron candidate itself and from the underlying event and pile-up contributions using the technique proposed in Ref. [15] and implemented as described in Ref. [16]. A track isolation variable pTiso is also used for electrons and muons. It is built by summing the transverse momenta of the tracks in a cone of size R around the candidate, excluding the track associated with the candidate itself. The tracks considered in the sum must come from the reconstructed vertex with the highest sum of all associated tracks and must have at least four hits in either the pixel or SCT detector. 3 Overview of the calibration procedure The different steps in the procedure to calibrate the energy response of electrons and photons described in this paper are summarised below, with the item numbers referring to the 5 This cut is only applied when the traversed module is active. 123 calibration steps sketched in Fig. 1. The references to their description in the paper is also given. The energy of an electron or photon candidate is built from the energy of a cluster of cells in the EM calorimeter. The calibration proceeds as follows: 1. The EM cluster properties, including its longitudinal development, and additional information from the ATLAS inner tracking system, are calibrated to the original electron and photon energy in simulated MC samples using multivariate techniques (step 1), which constitutes the core of the MC-based e/γ response calibration (step 4). The calibration constants are determined using a multivariate algorithm (MVA) [17]; its optimisation is performed separately for electrons, converted and unconverted photons. The MC samples used in the various analyses presented in this paper are detailed in Sect. 4, while the MC-based MVA calibration is described in Sect. 5. A prerequisite of this MC-based calibration is that the detector geometry and the interactions of particles with matter are accurately described in the simulation. The material distribution is measured in data using the ratio of the first-layer energy to the second-layer energy in the longitudinally segmented EM calorimeter (E 1/2 ). Measuring E 1/2 in data with different samples (electrons and unconverted photons) allows a precise determination of the amount of material in front of the calorimeter and provides some sensitivity to its radial distribution as described in Sect. 8. 2. Since the EM calorimeter is longitudinally segmented, the scales of the different longitudinal layers have to be equalised in data with respect to simulation, prior to the determination of the overall energy scale, in order to ensure the correct extrapolation of the response in the full pT range used in the various analyses (step 2). The Eur. Phys. J. C (2014) 74:3071 Page 5 of 48 3071 Sect. 11. The scale factors extracted from Z → ee events are assumed to be valid also for photons, while photonspecific systematic uncertainties are applied, as discussed in Sect. 12. This approach is validated with photon candidates from Z → γ events in data, and discussed in Sect. 13. procedure to measure the EM calorimeter layer scales is reviewed in Sect. 7. 3. The MC-based e/γ response calibration is applied to the cluster energies reconstructed both from collision data and MC simulated samples (step 3). 4. A set of corrections are implemented to account for response variations not included in the simulation in specific detector regions (step 4), e.g. non-optimal HV regions, geometric effects such as the inter-module widening (IMW) or biases associated with the LAr calorimeter electronic calibration. These corrections are discussed in Sect. 6, where the stability of the calorimeter response as a function of φ, time and pile-up is also presented. 5. The overall electron response in data is calibrated so that it agrees with the expectation from simulation, using a large sample of Z → ee events as discussed in Sect. 9. Per-electron scale factors are extracted and applied to electron and photon candidates in data (step 5). Using the same event sample it is found that the resolution in data is slightly worse than that in simulation, and appropriate corrections are derived and applied to simulation to match the data. The electron and photon calibration uncertainties are summarised in Sect. 10. 6. The calibrated electron energy scale is validated with electron candidates from J/ψ → ee events in data (step 6). The scale dependence with η and pT , and its associated systematic uncertainties are summarised in Table 1 Summary of the processes used in the present calibration analysis, the kinematic selections, the numbers √of events selected in data at s = 8 TeV (for 20.3 fb−1 ) and the MC signal samples used. The region 1.37 ≤ |η| < 1.52 is excluded for photons The determination of the electron and photon energy resolution, and the associated uncertainties, are described in Sect. 14. Finally, the potential for improving the electron energy resolution, by combining the cluster energy with the momentum measured by the ID, is described in Sect. 15. 4 Collision data and simulated samples The results presented in this paper are primarily based on √ 20.3 fb−1 of pp collision data at s = 8 TeV, collected by ATLAS in 2012. The results of the application of the same √ methods to 4.7 fb−1 of pp collision data taken in 2011 at s = 7 TeV are described in Appendix A. Table 1 lists the kinematic selections applied to the different calibration samples, the generators used and the corresponding numbers of events in 2012 collision data. The average electron transverse energy is around E Te ∼ 40–45 GeV in the W and Z samples and E Te ∼ 11 GeV in the J/ψ samγ ple; for photons, E T ∼ 25,100 GeV in the Z → γ and γ + X samples, respectively. The W event selection relies Process Selections data Nevents MC generator Z → ee E Te > 27 GeV, |ηe | < 2.47 5.5 M Powheg+Pythia 80 < m ee < 100 GeV W → eν E Te > 30 GeV, |ηe | < 2.47 34 M Powheg+Pythia J/ψ → ee E Tmiss > 30 GeV, m T > 60 GeV E Te > 5 GeV, |ηe | < 2.47 0.2 M Pythia 7M Sherpa E T > 15 GeV, |ηγ | < 2.37 20k (e) Sherpa E Te > 15 GeV, |ηe | < 2.47 40k (μ) 2 < m ee < 4 GeV Z → μμ μ pT > 20 GeV, |ημ | < 2.4 60 < m μμ < 120 GeV Z → γ , large-angle γ μ pT > 20 GeV, |ημ | < 2.4 45 < m  < 85 GeV 80 < m γ < 120 GeV R(, γ ) > 0.4 Z → μμγ , collinear γ E T > 7 GeV, |ηγ | < 2.37 120k Sherpa 3.1 M Pythia μ pT > 20 GeV, |ημ | < 2.4 55 < m μμ < 89 GeV 66 < m μμγ < 116 GeV R(μ, γ ) < 0.15 γ+X E T > 120 GeV, |ηγ | < 2.37 123 3071 Page 6 of 48 on E Tmiss and φ miss , respectively defined as the norm and azimuth of the total transverse momentum imbalance of all reconstructed objects, and on the transverse mass defined as  m T = 2E Te E Tmiss (1 − cos φ) where φ = φ e −φ miss , φ e being the azimuthal angle of the electron. The J/ψ sample results from both direct production and b → J/ψ decays. Three different triggers are used for this sample requiring a transverse energy of the leading lepton above 4, 9 and 14 GeV respectively. The trigger requirement significantly affects the electron E T distribution in this sample, which is not the case for the other calibration samples. In the Z → γ sample, photons and electrons are required to have a large-angle separation. A collinear sample in the Z → μμγ channel, where the photon is near one of the muons, is also selected. Isolation requirements are applied to photons and leptons. In the large-angle sample, leptons are required to have pTiso ( R = 0.2)/ pT < 0.1; in addition electrons are required to satisfy E Tiso ( R = 0.3)/ pTe < 0.18 while for photons E Tiso ( R = 0.4) < 4 GeV. In the collinear sample, the same isolation cut is applied to photons, but it μ is tightened for muons by applying pTiso ( R = 0.3)/ pT < 0.15. The measurements are compared to expectations from MC simulation. Comparisons between data and simulation are initially performed using the detector description originally used for most ATLAS analyses (see for instance Ref. [1]), later referred to as the “base” simulation. The detector description resulting from the passive material determination described in Sect. 8 is instead referred to as the “improved” simulation. Large samples of Z → ee, Z → μμ, J/ψ → ee, W → eν, Z → γ and γ + X events were generated with Sherpa [18] and Powheg [19–22] interfaced with Pythia [23]. The generated events are processed through the full ATLAS detector simulation [24] based on Geant4 [25]. The size of the MC samples exceeds the corresponding collision data samples by a factor of up to 10. For the optimisation of the MC-based e/γ response calibration, a sample of 20 million single electrons, and one of 40 million single photons are simulated. The E T distribution of such samples is tuned to cover the range from 1 GeV to 3 TeV, while maximising the statistics between 7 and 100 GeV. For studies of systematic uncertainties related to the detector description in simulation, samples with additional passive material in front of the EM calorimeter are simulated, representing different estimates of the possible amount of material, based on studies using collision data [26–31]. Depending on the signal samples, backgrounds consist of W → ν, Z → τ τ and gauge boson pair production, simulated using Powheg; bb̄, cc̄ → μ + X simulated using Pythia; and t t¯ production, simulated using Mc@nlo [32]. For the Z → γ analysis, backgrounds from Z production in association with jets are simulated using Sherpa. 123 Eur. Phys. J. C (2014) 74:3071 Some background contributions are directly determined from data. The MC events are simulated with additional interactions in the same or neighbouring bunch crossings to match the pile-up conditions during LHC operation, and are weighted to reproduce the distribution of the average number of interactions per bunch crossing in data. 5 MC-based calibration for electrons and photons Reconstructed electron and photon clusters are calibrated to correct for the energy lost in the material upstream of the calorimeter, the energy deposited in the cells neighbouring the cluster in η and φ, and the energy lost beyond the LAr calorimeter. Further corrections are applied to correct for the response dependence as a function of the particle impact point within the central cluster cell. The cluster-level calibration constants are extracted from simulated electrons and photons and strongly rely on the assumed amount of passive material in front of the EM calorimeter. The simulation of the detector material uses the improvements described in Sect. 8. The constants are determined using a multivariate algorithm, applied separately for electrons, converted and unconverted photons in η and pT bins. The calibration method presented in this section supersedes the procedure described in Refs. [3,33], except for the transition region 1.37 ≤ |η| < 1.52 where the initial calibration procedure is still used. 5.1 Input variables The calibration procedure optimises the estimate of the true particle energy at the interaction point (E true ) from the detector-level observables. The algorithm uses cluster position measurements in the ATLAS and EM calorimeter frames. The ATLAS coordinate system has its origin at the nominal interaction point, with respect to which the calorimeter is displaced by a few millimeters, while all calorimeter cells are in their nominal position in the EM calorimeter frame. The quantities used for electrons and photons are the total energy measured in the calorimeter, E calo ; the ratio of the PS energy to the calorimeter energy, E 0 /E calo ; the shower   depth, defined as X = i X i E i / i E i , where E i and X i are the cluster energy and the calorimeter thickness (in radiation lengths) in layer i; the cluster barycentre pseudorapidity in the ATLAS coordinate system, ηcluster ; and the cluster barycentre in η and φ within the calorimeter frame. The variable ηcluster is included to account for the passive-material variations in front of the calorimeter; the inclusion of the barycentre location in the calorimeter frame is important to accurately correct for the increase of lateral energy leakage Eur. Phys. J. C (2014) 74:3071 for particles that hit the cell close to the edge, and for the sampling fraction variation as a function of the particle impact point with respect to the calorimeter absorbers. Photons are considered converted if the conversion radius Rconv is smaller than 800 mm. For these converted photons, Rconv is used as an additional input to the MVA only if the vectorial sum of the conversion track momenta, pTconv , is above 3 GeV. In particular for conversions with both tracks containing at least one hit in either the pixel or SCT detector, further quantities are considered: the ratio pTconv /E calo ; and the fraction of the conversion momentum carried by the highest- pT track, pTmax / pTconv . 5.2 Binning and linearity corrections To help the MVA optimise the energy response in different regions of phase space, the sample is divided into bins of |ηcluster |, E Tcalo , and according to the particle type (electron, unconverted photon or converted photon). The binning is chosen to follow the known detector geometry variations and significant changes in the energy response. A rectangular mesh of 10 × 9 bins in |ηcluster | × E Tcalo is defined, and 2 × 6 bins are defined in addition for the regions close to the edges of the two half-barrel modules: • |ηcluster |: 0 – 0.05 – 0.65 – 0.8 – 1.0 – 1.2 – 1.37 ; 1.52 – 1.55 – 1.74 – 1.82 – 2.0 – 2.2 – 2.47, where 1.37 – 1.52 is excluded and 0 – 0.05 and 1.52 – 1.55 are edge bins. • E Tcalo (normal bins): 0 – 10 – 20 – 40 – 60 – 80 – 120 – 500 – 1,000 and 5,000 GeV. • E Tcalo (edge bins): 0 – 25 – 50 – 100 – 500 – 1,000 and 5,000 GeV. Page 7 of 48 3071 ing the first and the last quartiles of the E/E true distribution in each bin, normalised to 1.35 standard deviations, its equivalent definition for a normal distribution. These estimators are chosen to reflect the influence of energy tails. The obtained MVA calibration non-linearity is everywhere below 0.3 % for E Ttrue above 10 GeV, better than 1 % at lower transverse energies, only reaching 2 % in localised regions for converted photons. An improvement of more than a factor two compared to the initial calibration is achieved, in particular in the high |η| region. For the resolution, improvements of about 3–10 % in the barrel and 10–15 % in the endcap are obtained for unconverted photons. For converted photons in the same energy range, the resolution is improved by typically 20 %. For electrons, improvements of a few percent are obtained on average, except at 1.52 < |η| < 1.8 where they vary from 10 to 30 % depending on E T . While the resolution estimator used here reproduces the expected sampling √ term resolution for unconverted photons (σ/E ∼ 0.1/ E on average), the worse resolution obtained for electrons and converted photons reflects the presence of significant energy tails induced by interactions with the material upstream of the calorimeter. Figure 3 compares the performance of the MVA calibration with the initial calibration in simulated H → γ γ (m H = 125 GeV) and J/ψ → ee events. The invariant mass resolution of the former improves by 10 % on average, with a maximum improvement of 15 % for converted photons or in the barrel–endcap transition region. The latter reflects the expected linearity improvement; no significant resolution improvement is obtained. 6 Uniformity and stability An independent optimisation is performed for each bin. Multivariate algorithms aim at optimising the energy response and minimising the root mean square (RMS) resolution. The presence of tails in the energy response results in remaining non-linearities which are corrected by adjusting the peak position of the ratio of the output energy E MVA to E true to unity. These corrections range from +2 to +5 % depending on η at E T = 10 GeV, and rapidly decrease to zero around 100 GeV. 5.3 Performance The linearity and resolution of the MVA calibration are illustrated in Fig. 2. The linearity is defined as the deviation of the peak position of E/E true from unity as a function of E Ttrue , estimated by the most probable value (MPV) of a Gaussian function fitted to the core of the distribution in each (E Ttrue , |η|) bin. The fits are restricted to the range [−1, +2] standard deviations. The resolution σeff is defined as the interquartile range of E/E true , i.e. the interval exclud- Good uniformity of the EM calorimeter energy reconstruction across pseudorapidity and azimuthal angle, and excellent stability of the response as a function of time and pile-up conditions, are necessary to achieve optimal energy resolution in data. They also constitute a prerequisite for the passive material determination and energy scale measurement presented in Sects. 7–9. The present section describes a set of studies, √ based on the data collected at s = 8 TeV, aiming to correct for local non-uniformities in the calorimeter response. The response uniformity is investigated using E/ p for electrons in W → eν events and the electron pair invariant mass in Z boson decays. Four classes of effects are discussed below. The stability of the response as a function of φ, time and pile-up is presented after all corrections are applied. 6.1 High-voltage inhomogeneities In a few sectors (of typical size η × φ = 0.2 × 0.2) of the EM calorimeter, the HV is set to a non-nominal value due to 123 3071 Page 8 of 48 Eur. Phys. J. C (2014) 74:3071 1.02 0.08 1.005 0.06 1 0.04 0.995 0.02 0.99 0 0.5 1 1.5 2 0 2.5 ATLAS Simulation Electrons 25 GeV 50 GeV 100 GeV 200 GeV 1000 GeV 0.1 σeff/E MPV 1.01 0.12 ATLAS Simulation Electrons 25 GeV 50 GeV 100 GeV 200 GeV 1000 GeV 1.015 0 0.5 1 |η| 1.5 2 2.5 |η| 1.02 Unconverted photons 0.08 1.005 0.04 0.995 0.02 0 0.5 1 1.5 2 0 2.5 Unconverted photons 0.06 1 0.99 ATLAS Simulation 25 GeV 50 GeV 100 GeV 200 GeV 1000 GeV 0.1 σeff/E MPV 1.01 0.12 ATLAS Simulation 25 GeV 50 GeV 100 GeV 200 GeV 1000 GeV 1.015 0 0.5 1 |η| 1.5 2 2.5 |η| 1.02 0.08 1.005 0.06 1 0.04 0.995 0.02 0.99 0 0.5 1 1.5 2 2.5 |η| ATLAS Simulation Converted photons 25 GeV 50 GeV 100 GeV 200 GeV 1000 GeV 0.1 σeff/E MPV 1.01 0.12 ATLAS Simulation Converted photons 25 GeV 50 GeV 100 GeV 200 GeV 1000 GeV 1.015 0 0 0.5 1 1.5 2 2.5 |η| Fig. 2 Most probable value (MPV) of E/E true and relative effective resolution σeff /E as a function of |η| for different energies, for electrons (top), unconverted photons (middle) and con- verted photons (bottom). The points at E = 25 GeV are shown only for |η| < 1.37, where they correspond to E T > 10 GeV short circuits occurring in specific LAr gaps [11]. The effect of such modifications is first corrected at the reconstruction level using the expected HV dependence of the response. The azimuthal profiles of the electron pair invariant mass in Z → ee events, however, show localised residual effects, affecting less than 2 % of the total number of HV sectors in the EM calorimeter [7]. An empirical correction is derived based on these profiles to restore the azimuthal uniformity in the problematic sectors. The average value of m ee as a function of the azimuthal position of its leading decay electron, for 0.4 < η < 0.6, is presented in Fig. 4 before and after this correction. In this example, two sectors are set to a non-nominal HV, inducing a decrease of the response by about 2 % at φ ∼ −1 and φ ∼ 0. After correction, the response is uniform. 123 Eur. Phys. J. C (2014) 74:3071 Page 9 of 48 3071 0.06 H→γ γ 0.05 s = 8 TeV 0.03 J/ ψ →ee s = 8 TeV 0.02 0.015 0.02 0.01 0.01 0.005 0 0 2.2 116 118 120 122 124 126 128 130 132 134 2.4 2.6 2.8 mγ γ [GeV] 3.2 3.4 3.6 3.8 4 The same comparison for the dielectron invariant mass distributions, m ee , for simulated J/ψ → ee decays (right). The vertical dashed lines indicate the simulated masses 0.02 95 ATLAS 93 s = 8 TeV; 92 Uncorrected ∫ Ldt = 20.3 fb -1 0.015 Corrected (E0P2 - E0P1) / E0P2 94 [GeV] 3 mee [GeV] Fig. 3 Comparison of the diphoton invariant mass distributions, m γ γ , for a simulated Standard Model Higgs boson with a mass of 125 GeV, obtained with the initial calibration and with the MVA calibration (left). 91 90 89 88 87 0.01 ATLAS s = 8 TeV; Uncorrected ∫ Ldt = 20.3 fb -1 Corrected 0.005 0 -0.005 -0.01 -0.015 0.4 < η < 0.6 86 85 Initial calibration MPV = 3.055 GeV σeff = 0.146 GeV MVA MPV = 3.109 GeV σeff = 0.147 GeV ATLAS Simulation 0.025 a.u. a.u. 0.04 0.03 Initial calibration MPV = 124.48 GeV σeff = 1.55 GeV MVA MPV = 124.93 GeV σeff = 1.39 GeV ATLAS Simulation -3 -2 -0.02 -1 0 1 2 3 φ Fig. 4 Average value of m ee as a function of the azimuthal position of the leading decay electron with 0.4 < η < 0.6, before and after the HV correction. The error bars include statistical uncertainties only 6.2 Time dependence of the presampler response The nominal HV in the EM barrel PS is 2,000 V. To limit the increasing occurrence of sporadic electronics noise [3] with increasing luminosity, the operating HV was reduced to 1,600 V during the 2011 run and until September 2012 (period P1). The HV was later further reduced to 1,200 V, with some sectors brought down to 800 V (period P2). As above, the non-nominal HV is at first compensated at the cell level using a correction defined from the expected HV dependence of the PS response. This correction is of the order of 8 % for P1 and 21 % for P2. The accuracy of the correction is verified by comparing the PS response for electrons from Z → ee data between P1 and P2; a residual η-dependent variation of up to 1 % is observed. An additional empirical correction is applied to the PS energy at the cluster level, reducing the bias to 0.4 % -1.5 -1 -0.5 0 η 0.5 1 1.5 Fig. 5 Relative difference in the raw PS energy response due to the change in HV settings, as a function of η, before and after correction of the residual HV dependence. The periods before and after the HV change are referred to as P1 and P2, respectively. The error bars include statistical uncertainties only across η. The residual response bias and its corrections are illustrated in Fig. 5. 6.3 Energy loss between the barrel calorimeter modules When probing the energy response versus φ using the MPV of the E/ p distribution in W → eν events in data, a π/8periodical structure is observed. The period and the location of the effect correspond to the transitions between the barrel calorimeter modules. The size of the modulation is ∼2 % in the φ > 0 region and ∼1 % for φ < 0, and is interpreted as a gravity-induced widening of the inter-module gaps. The energy loss is adjusted with an empirical function which is then used to correct the calorimeter response. The effect of the inter-module widening and its correction are shown in Fig. 6. This effect is not observed in the EMECs. 123 3071 Page 10 of 48 Eur. Phys. J. C (2014) 74:3071 5 ATLAS 1.03 s = 8 TeV; 1.02 ∫ Ldt = 20.3 fb 1 0.99 0.97 -3 s = 8 TeV; 3 Corrected 1.01 0.98 ATLAS 4 Uncorrected -1 MC data - mee [GeV] mee Relative energy response 1.04 2 -1 -2 -3 0.2<η<0.4 -2 -5 20 30 1 2 3 40 50 φ 6.4 Energy response in high and medium gain To accommodate the wide range of expected energies in the calorimeter cells, the electronic signals are treated with three gains (see Sect. 2.2). In Z → ee events, used for the absolute energy scale determination (see Sect. 9), most electron clusters have all their L2 cells recorded in HG. In the case of H → γ γ (m H = 125 GeV) for example, roughly 1/3 of the events have a photon with at least one cell in MG. The reconstructed electron pair invariant mass is compared between data and simulation as a function of the electron energy, for events where all electron cluster cells in L2 are in HG and for those where at least one cell is in MG. In most of the calorimeter, the energy calibration is found to be gain independent within uncertainties; however, a percentlevel effect is seen in specific η regions (around |η| ∼ 0.6 and |η| ∼ 1.6). Two example regions are illustrated in Fig. 7 for 0.2 < η < 0.4 and 1.52 < η < 1.62. The observed effect is symmetric in η. The observed gain dependence of the energy response is removed by applying a correction defined from the data–MC difference of the energy response in HG and MG, multiplied by the expected fraction of clusters with at least one L2 cell in MG at given η and E T . The LG case, relevant only at very high energy, is assumed to have the same correction as the MG. 6.5 Azimuthal non-uniformity and operational stability after corrections The azimuthal non-uniformity before and after the corrections described above is shown in Fig. 8. This non-uniformity is defined as the RMS of the energy response versus φ, probed 123 60 70 80 90 100 E [GeV] 5 ATLAS 4 MC data - mee [GeV] mee Fig. 6 Relative energy response of electrons as a function of φ, before and after correction for the intermodule widening effect, for 0 < η < 0.8. The relative energy scale is defined from the MPV of the E/ p distribution in W events, normalised to its average over φ. The error bars include statistical uncertainties only Medium gain 0 -4 0 ∫ Ldt = 20.3 fb 1 0.0 < η < 0.8 -1 High gain -1 s = 8 TeV; 3 2 High gain ∫ Ldt = 20.3 fb -1 Medium gain 1 0 -1 -2 -3 1.52<η<1.62 -4 -5 60 80 100 120 140 160 180 200 220 240 E [GeV] Fig. 7 Difference between data and simulation of the average reconstructed Z boson mass as a function of the energy of one electron, for events where all cluster cells are in high gain from those where at least one cell is in medium gain, in a good region (top) and in a region with a significant bias (bottom). The error bars include statistical uncertainties only with a granularity of φ = 0.025, after having subtracted the contribution from the expected statistical fluctuations. The energy response is probed using the electron pair invariant mass peak in Z → ee events, and the non-uniformity is defined from the RMS of the response versus φ, probed with a granularity of φ = 0.025, corresponding to one cell in L2, and for coarse η bins; the contribution of the expected statistical fluctuations is subtracted in quadrature. The result can be interpreted as the non-uniformity contribution to the longrange resolution constant term. A non-uniformity of 0.45 % is achieved for |η| < 0.8, and 0.75 % is obtained in the rest of the calorimeter. The stability of the electron energy response as a function of the mean number of interactions per bunch crossing (μ), and as a function of time was measured using electrons from Z boson decays. The results presented in Figs. 9 and 10 show stability at the level of 0.05 %. The stability of the response as a function of the number of reconstructed colli- Eur. Phys. J. C (2014) 74:3071 Page 11 of 48 3071 ATLAS s=8 TeV; ∫ Ldt=20.3 fb 0.8 0.6 0.4 0.2 Uncorrected HV, PS, IMW, Gain corrections 0 -2 -1.5 -1 -0.5 0 0.5 1 1.5 E/p 1.001 1.0005 1 0.9995 0.999 ∫ s = 8 TeV, Ldt = 20.3 fb-1 15 20 0.9995 0.999 0.9985 25 ∫ s = 8 TeV, Ldt = 20.3 fb-1 ATLAS 23/04 04/06 16/07 27/08 07/10 18/11 30/12 Fig. 10 Energy response as a function of time, normalised to its average quantity. The energy response is probed using the peak position of the electron pair invariant mass peak in Z events and the MPV of the E/ p distribution in W events; each point in time represents a recorded amount of data of around 100 pb−1 . The error bars include statistical uncertainties only Relative energy response Relative energy response mee 1.0015 10 1 Date (Day/Month) 1.002 0.998 1.0005 2 Fig. 8 Azimuthal non-uniformity of the energy response as a function of η, estimated from the electron pair invariant mass peak in Z → ee events ATLAS E/p 1.001 0.998 13/03 η 0.9985 mee 1.0015 30 μ Fig. 9 Energy response as a function of μ, normalised to its average. The energy response is probed using the peak position of the electron pair invariant mass peak in Z events and the MPV of the E/ p distribution in W events, and μ is defined as the expected number of pp interactions per bunch crossing. The error bars include statistical uncertainties only data/MC Non-uniformity (%) 1 1.002 -1 Relative energy response 1.2 1.004 data MC 1.003 1.002 1.001 1 0.999 0.998 ∫ s=8 TeV, Ldt = 20.3 fb-1 ATLAS 0.997 0.996 1.001 1.0005 1 0.9995 0.999 0 5 10 15 20 25 30 N vtx Fig. 11 Top energy response as a function of Nvtx , normalised to its average. The energy response is probed using the peak position of the electron pair invariant mass in Z events. Bottom ratio of data to simulation. The error bars include statistical uncertainties only sion vertices (Nvtx ) is shown in Fig. 11. Classifying events according to Nvtx , related to the actual number of interactions per bunch crossing, biases the pile-up activity of the colliding bunch with respect to the average. In this case the compensation of the pile-up contribution to the reconstructed energy by the bipolar shaping becomes imperfect, giving rise to the observed slope. The description of this effect in the simulation is accurate to 0.05 %. determination of the PS energy scale exploits the PS energy distributions of electrons in data and simulation, after effective corrections for possible mis-modelling of the upstream passive material. The results are verified by a study of the electron energy response as a function of shower depth. No dedicated intercalibration of the third EM longitudinal layer is carried out, as its contribution is negligible in the energy range covered by the present studies. 7 Intercalibration of the LAr calorimeter layers 7.1 Intercalibration of the first and second calorimeter layers Corrections are needed in data to adjust residual effects not perfectly accounted for by the cell electronic calibration discussed in Sect. 2.2. The intercalibration of the first and second calorimeter layers uses muons from Z → μμ decays as probes, while the Muon energy deposits in the calorimeter are insensitive to the amount of passive material upstream of the EM calorimeter and constitute a direct probe of the energy response. The measured muon energy is typically 60 MeV in L1 and about 123 3071 Page 12 of 48 • uncertainty in the exact path length traversed by muons, related to uncertainty in the geometry of the read-out cells; • uncertainty in the effect of the reduced electric field at the transition between the different calorimeter layers; • uncertainty in the modelling of the conversion of deposited energy to ionisation current due to variations in the electric field following the accordion structure of the absorbers and electrodes; 123 1.1 Z→μμ (trunc. mean) Z→μμ (MPV) 1.05 data MC E1/2 / E1/2 210 MeV in L2, with a signal-to-noise ratio of about three [7]. Muon energy deposits are very localised, most of the energy being deposited in one or two cells. Since the critical energy for muons interacting with the calorimeter is of the order of 100 GeV, most muons from Z → μμ decays are minimum ionising particles. The analysis uses muons from Z → μμ decays, requiring μ pT > 25 GeV. The calorimeter cells crossed by the muon tracks are determined by extrapolating the muon tracks to each layer of the calorimeter, taking into account the geometry of the calorimeter and the residual magnetic field seen by the muon along its path in the calorimeter. In L1, the muon signal is estimated by summing the energies measured in three adjacent cells along η, centred around the cell of highest energy among the few cells around the extrapolated track. In L2, due to the accordion geometry, the energy is most often shared between two adjacent cells along φ; hence the signal is estimated from the sum of the highest energy cell and its most energetic neighbour in φ. The observed muon energy distribution in each layer is given by the convolution of a Landau distribution describing the energy deposit, and a Gaussian distribution corresponding to the electronic noise. The MPV of the deposited energy is extracted using an analytical fit with the convolution model, or is alternatively estimated using a truncated mean, by defining the interval as the smallest one containing 90 % of the energy distribution. Denoting E 1/2  the ratio of the MPVs in L1 and L2, the intercalibration result is defined as α1/2 = E 1/2 data /E 1/2 MC . The central value of α1/2 is given by the average of the two methods; the difference is used to define its systematic uncertainty. The statistical uncertainty is negligible. The result is illustrated in Fig. 12. All features are observed to be symmetric within uncertainties with respect to η = 0, and are therefore shown as a function of |η|. In the barrel, a negative bias of about 3 % is observed; it shows a falling structure from |η| = 0 to 0.8 and from |η| = 0.8 to 1.4, with a positive step at the boundary between these regions. In the endcap, α1/2 ∼ 1 on average, but its behaviour across pseudorapidity is not uniform. The intercalibration of the calorimeter layers with muons relies on the proper modelling in the simulation of the induced ionisation current by muons in each calorimeter layer. The following sources of uncertainty are considered: Eur. Phys. J. C (2014) 74:3071 Average 1 0.95 ∫ s = 8 TeV, Ldt = 20.3 fb-1 ATLAS 0.9 0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2 2.2 2.4 |η| Fig. 12 Ratio E 1/2 data /E 1/2 MC as a function of |η|, as obtained from the peak position of muon energy deposits in L1 and L2, and from the mean of these energy deposits computed in an interval containing 90 % of the distribution. The error bars represent the total uncertainty specific to the Z → μμ analysis • uncertainty in the cross-talk between different calorimeter cells (between L1 cells, between L1 and L2 cells and between L2 cells) [34] which affects the measured energy for muons (using three cells in L1 and two cells in L2). These uncertainties are evaluated by implementing the corresponding changes in the simulation. The resulting uncertainty on the relative calibration of L1 and L2 rises from 1 to 1.5 % with the pseudorapidity in the barrel and is 1.5 % in the endcap. These uncertainties are also propagated to uncertainties on the modelling of E 1/2 for electrons and photons, as this variable is used in Sect. 8 for the passive-material determination. For this modelling, the difference between data and simulation in the description of lateral EM shower shape is also taken into account, as it affects L2 more than L1. In addition, the HG response in L1 is found to be sensitive to the pile-up-dependent optimisation of the OFC, for 1.8 < |η| < 2.3, with an uncertainty rising from 1 to 5 % in this region. Since in this region most high-E T EM showers have their highest energy cell in L1 recorded in MG, this additional uncertainty is accounted for when applying the muon-based calibration to electrons or photons. The L1/L2 calibration bias α1/2 discussed in this section is removed by applying an |η|-dependent correction to the layer intercalibration in data. The correction can be applied to the energy measured either in L1 (by defining E 1corr = E 1 /α1/2 ) or in L2 (E 2corr = E 2 × α1/2 ). The latter option is chosen, as a direct comparison of E 2 in data and simulation shows that the pattern vs |η| observed in Fig. 12 is localised in L2. After all other corrections discussed in the rest of the paper are applied, and in particular the overall energy scale correction discussed in Sect. 9, the calibrated particle energy is unaffected by this choice. Eur. Phys. J. C (2014) 74:3071 Page 13 of 48 3071 1.2 1.2 ATLAS s=8 TeV; ATLAS ∫ Ldt=20.3 fb -1 1.15 0.6<|η|<0.7 MC 1.1 E0var / E0 E0var / E0MC 1.15 1.05 ID variations A = 2.48; b1/2 = 1 1 Data (Z→ ee) 0.9 0.9 0.95 1 1.05 1.1 1.15 ∫ Ldt=20.3 fb -1 1.2 1.0<|η|<1.1 1.1 1.05 ID variations A = 1.65; b1/2 = 1 1 ID+calo variations A = 2.48; b1/2 = 1.026 0.95 s=8 TeV; ID+Calo variations A = 1.65; b1/2 = 1.031 0.95 0.9 0.9 Data (Z→ ee) 0.95 1 1.05 1.1 1.15 1.2 MC Evar 1/2 / E1/2 MC Evar 1/2 / E1/2 Fig. 13 Examples of correlation between E 0 and E 1/2 ratios under material variations upstream of the calorimeter in the simulated sample, and their corresponding linear parameterisations, for 0.6 < |η| < 0.7 (left) and 1.0 < |η| < 1.1 (right). ID material variations refer to additions of up to 15 %X 0 inside the ID volume (circles). Calorimeter variations correspond to 5 %X 0 added between the PS and L1, separately or in addition to ID material variations (squares). The predictions of E 0 var , are normalised and E 1/2 in the simulation variations, E 0var and E 1/2 MC . to their values predicted by the nominal simulation, E 0MC and E 1/2 The triangle shows the values obtained from Z → ee data, after L1/L2 calibration correction. The errors bars are statistical only 7.2 Presampler energy scale MC are the predicted values of E and E where E 0MC and E 1/2 0 1/2 var their values in the nominal simulation, and E 0var and E 1/2 in the varied simulations. The simulation samples described above predict A = 2.48±0.09 for |η| < 0.8, and A = 1.65± 0.05 for |η| > 0.8. Assuming correct L1/L2 calibration, b1/2 parameterises the remaining potential mis-modelling of E 1/2 for effects unrelated to the material upstream of the PS (such as an imperfect description of the passive material between the PS and L1 and a possible mis-modelling of the cross-talk between L1 and L2); by definition b1/2 ≡ 1 in the absence of bias. Correlating the data/MC ratios of E 0 and E 1/2 thus approximately removes the impact of local material variations on the former, and provides a corrected prediction for this quantity,   data (η) E 1/2 E 0corr (η) = 1 + A(η) −1 , (4) MC (η) b E 0MC (η) E 1/2 1/2 (η) The presampler energy scale αPS is determined from the ratio of PS energies in data and MC simulation and estimated using electrons from W and Z decays. Before this ratio can be interpreted in terms of an energy scale, the effects of passivematerial mis-modelling must be taken into account, as an inaccurate passive-material description in the detector affects the electron shower development and hence the predicted PS energy distributions with respect to the data, resulting in an apparent energy scale bias. This is addressed by exploiting the expected correlation between E 1/2 and E 0 for electrons, at a given η value, under variations of the passive material upstream of the PS. To study this correlation, a set of detector material variations is implemented in simulation, increasing the passive material in the various detector sub-systems upstream of the PS (ID, services, cryostat) and within the calorimeter volume between the PS and L1. The results are illustrated in Fig. 13. Simulations with additional passive material upstream of the PS result in an earlier shower and simultaneously increase the PS activity and E 1/2 ; a linear correlation between these observables is observed. Simulations also including passive material between the PS and L1 exhibit the same slope of E 0 versus E 1/2 , but with an offset along E 1/2 as material additions after the PS can not affect the PS activity, but generate earlier showers in the calorimeter. The following linear parameterisation describes the impact of upstream passivematerial variations on E 0 and E 1/2 : E 0var (η) E 0MC (η)  = 1 + A(η) var (η) E 1/2 MC (η) b E 1/2 1/2 (η)  −1 , (3) where E 0corr (η) corresponds to the amount of expected PS energy in the simulation, corrected for local material bias via data (η) and b E 1/2 1/2 (η). Finally, the PS energy scale is defined by αPS (η) = E 0data (η) . E 0corr (η) (5) The offset b1/2 is probed using a sample of unconverted photons selected from radiative Z decays and inclusive phodata /E MC for this ton production, and defined as b1/2 ≡ E 1/2 1/2 sample. In addition to the identification criteria summarised in Sect. 2, the unconverted photon sample should satisfy E 0 < 500 MeV to limit the probability that a conversion occurred between the end of the ID and the PS. It is verified 123 3071 Page 14 of 48 Eur. Phys. J. C (2014) 74:3071 1.4 ∫ ATLAS 1.3 1.25 -1 s=8 TeV, Ldt = 20.3 fb 1.2 MC E0data / E0 MC data E1/2 /E1/2 1.1 1 0.9 1 0.95 Corrected for L1/L2 calibration 0 0.2 0.4 0.6 0.8 1 0.8 1.2 1.4 1.6 1.8 2 2.2 2.4 1.15 Unconverted photons, E <0.5 GeV 0 1.1 0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 Fig. 15 Ratio of the average PS energies, E 0data /E 0MC , for electrons in data and simulation as a function of |η|, before and after corrections for b1/2 and material upstream of the PS. The full lines with shaded bands represent the PS energy scale as a function of |η|, αPS (η), and its uncertainty ∫ s=8 TeV, Ldt = 20.3 fb-1 ATLAS 0.75 |η| 1.25 1.2 Uncorrected Corrected Module average 0.85 |η| MC 1.1 1.05 0.9 Uncorrected 0.8 data / E1/2 E1/2 -1 s=8 TeV, Ldt = 20.3 fb 1.15 Electrons 1.2 0.7 ∫ ATLAS 1.05 1 0.95 0.9 0.85 Uncorrected 0.8 Corrected for L1/L2 calibration 0.75 0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 |η| data /E MC , for electrons from W and Z decays. Fig. 14 Top ratio E 1/2 1/2 data /E MC for unconverted photons with Bottom b1/2 , defined as E 1/2 1/2 E 0 < 500 MeV. Both observables are shown as a function of |η|, before and after the L1/L2 calibration corrections. The errors bars on the uncorrected points are statistical only; after corrections, the error bars also include systematic uncertainties related to the L1/L2 calibration using simulation that this cut indeed minimises the sensitivity of this sample to material variations upstream of the PS, and that E 1/2 modelling uncertainties from material after the PS or cross-talk between L1 and L2 affect electrons and photons in a similar way, so that this photon sample probes b1/2 for electrons with an inaccuracy of less than 1–2 % depending on pseudorapidity. Figure 14 shows the comparison of E 1/2 between data and simulation for electrons and for the unconverted photon sample, before and after the L1/L2 calibration correction described in Sect. 7.1. Before this calibration correction, the ratio of data to MC simulation for electrons and photons is on average below one by 3 % in the barrel. After calibration corrections, b1/2 is everywhere close to one, which suggests that there is no significant material mis-modelling downstream of the PS. In contrast, the electron data in the endcap show a residual positive bias of about 7 % on average, indicating a discrepancy in the description of the material. An explicit passive-material measurement using these data is performed in Sect. 8. 123 Figure 15 summarises the PS scale calculated according to Eqs. (4) and (5) and Fig. 14, from which the corrected values are used as input to the calculation. The material corrections based on Eq. (4) visibly reduce the variations of E 0data /E 0corr versus η compared to E 0data /E 0MC , especially in the regions 0.6 < |η| < 0.8 and 1.52 < |η| < 1.82. After this correction, the PS energy scale αPS is defined by averaging E 0data /E 0corr over intervals corresponding to the PS module size ( η = 0.2 in the barrel, η = 0.3 in the endcap). As it is located in the transition region, the correction to the PS energy scale for the module covering 1.4 < |η| < 1.55 is not addressed by this analysis. For particles entering this region, αPS and its uncertainty are taken from the closest range among 1.2 < |η| < 1.4 and 1.52 < |η| < 1.82. The measured PS energy scale αPS defines a correction factor that is applied to the data. Uncertainties affecting its determination arise from the statistical and systematic uncertainties affecting b1/2 and A, and from the residual variations of E 0data /E 0corr within a PS module, which indicates that the material correction via Eq. (4) is only approximate. The stadata /E MC from the tistical uncertainty on E 0data /E 0MC and E 1/2 1/2 electron samples is negligible. The PS scale measurement is accurate to 2–3 %, depending on pseudorapidity. 7.3 Layer intercalibration cross-check The dependence of the electron energy response on shower depth allows a direct extraction of α1/2 for EM showers, providing a test of the baseline approach described in Sect. 7.1. Figure 16 shows the correlation between the invariant mass of electron pairs from Z → ee decays and E 1/2 for data and simulation, in the representative bin 0.4 < |η| < 0.6. The PS scale corrections determined in Sect. 7.2 are applied. Eur. Phys. J. C (2014) 74:3071 91 90.5 mee [GeV] 90 89.5 0.4<|η|<0.6 89 Data Data, E1/2×1.03, E1+E2=cst Data, E1×1.03 MC, Nominal s=8 TeV; MC, distorted 88.5 88 87.5 0.1 0.2 0.3 0.4 0.5 0.6 ∫ Ldt=20.3 fb -1 0.7 0.8 0.9 1 1.015 1.01 1.005 1 0.995 0.99 0.4<|η|<0.6 0.985 Data Data, E1/2×1.03, E1+E2=cst ATLAS Data, E1×1.03 -1 s=8 TeV; Ldt=20.3 fb MC, distorted 0.98 ∫ 0.975 0.97 0.2 0.4 0.6 0.8 1 E1/2 Fig. 16 Top m ee as a function of E 1/2 for the data (points), the nominal simulation (open circles), the simulation with additional material (open squares), the data with a 3 % scaling of E 1 (triangles), and the data with a 3 % scaling of E 1 with E 1 + E 2 kept constant (open stars). Bottom ratios of the curves shown in the top plot to the nominal simulation. The plots show values for electrons in the pseudorapidity bin 0.4 < |η| < 0.6. The error bars include statistical uncertainties only 0.15 8 Passive-material determination ∫ ATLAS -1 s=8 TeV, Ldt = 20.3 fb 0.1 0.05 μ e α1/2 - α1/2 After L1/L2 calibration corrections, the E 1/2 distribution observed for EM showers in the data can be used to quantify the amount of detector material upstream of the active calorimeter. Higher values of E 1/2 in data would indicate earlier shower development, and hence a local excess of material in comparison with the simulation. Although E 1/2 (η) is intrinsically a measure of the material integral in front of the calorimeter at a given pseudorapidity, the study is performed for different categories of EM showers (electrons, and unconverted photons without PS activity), providing partial information on the distance from the beam axis at which the material is probed. The detector material categories can be grouped under ID material; cryostat material (“Cryo”), designating material located between the maximal conversion radius and the ATLAS E1/2 Ratio to Nominal MC The ratio between data and the nominal simulation is not constant versus E 1/2 . A constant data-to-simulation ratio is recovered by rescaling the L1 response in data and recomputing the invariant mass accordingly, adjusting α1/2 to maximise the compatibility of the ratio with a horizontal line. This procedure is applied to derive α1/2 as a function of |η|, and the optimum is determined by χ 2 minimisation. The difference between the values of α1/2 obtained with this procedure and with the muon-based L1/L2 calibration are shown in Fig. 17 as a function of |η|. Good compatibility in the full pseudorapidity range is observed, confirming the validity of the muon-based calibration. For 1.2 < |η| < 1.37 and 1.52 < |η| < 1.82, the E 1/2 distributions for electrons in data and simulation differ significantly regardless of α1/2 , leading to poor convergence of the minimisation procedure and enhanced uncertainties in these bins. The uncertainties on the electron measurement include systematic contributions from detector material mismodelling and from uncertainties on the cross-talk between L1 and L2. To test the influence of passive material, a Z → ee sample with 20–35 %X 0 additional material, depending on |η|, is simulated and treated as the data. The α1/2 values extracted from this sample represent a conservative passivematerial contribution to the uncertainty on α1/2 , and contribute about 0.5 % on average, except for 1.37 < |η| < 1.82 where the uncertainty is 1–2 %. The influence of cross-talk is probed by rescaling the L1 response in data, requiring in addition that the sum of the L1 and L2 energies be constant. Such variations have no impact on the data/MC ratio and the contribution of this effect is negligible. These systematic variations are also illustrated in Fig. 16, for 0.4 < |η| < 0.6. Page 15 of 48 3071 0 -0.05 Measurement -0.1 LAr modelling uncertainty -0.15 0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2 2.2 2.4 |η| Fig. 17 Difference between the electron- and muon-based L1/L2 calie and α μ respectively, as a function of |η|. bration results, denoted α1/2 1/2 The uncertainty band reflects the systematic uncertainties affecting the muon result; the error bars represent the uncertainty on the electron result 123 3071 Page 16 of 48 Eur. Phys. J. C (2014) 74:3071 10 9 ATLAS Simulation ∂(X/X0) / ∂relE1/2 8 Electrons Unconverted photons, E0<0.5 GeV 7 6 5 4 3 2 1 0 0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2 2.2 2.4 |η| Fig. 18 Sketch of EM shower development for the different particle categories described in the text, for |η| < 1.82 (top) and |η| > 1.82 (bottom). The interaction point is located to the left of the figure PS; and calorimeter material (“Calo”), for passive material located between the PS and L1. 8.1 Methodology Electrons are sensitive to all detector material crossed along their trajectory, from the interaction point up to L1; unconverted photons are insensitive to the ID material upstream of the conversion radius. Within the PS acceptance (|η| < 1.82), a veto on the PS activity can be required to minimise the probability that a conversion happened in front of the PS, making such photons specifically sensitive to passive material between the PS and L1. The shower development for these different types of particles is sketched in Fig. 18. The sensitivity of E 1/2 for these probes of detector material is evaluated using simulated samples including the following variations: • +5 % relative scaling of the ID inactive material; • +10 %X 0 × cosh η in front of the barrel calorimeter; • +5 %X 0 × cosh η between the barrel PS and L1; • +15 %X 0 × tanh η at the end of the active SCT and TRT endcap detectors; • +15 %X 0 × tanh η at the end of the ID volume, in front of the EMEC cryostat; • +30 %X 0 × tanh η in front of the endcap calorimeter, for 1.5 < |η| < 1.82; • +5 %X 0 × tanh η between the endcap PS and L1. The material additions in the barrel are placed at constant radius, and their thickness is constant as a function of z, hence the material seen by particles coming from the interaction point increases with pseudorapidity as indicated above. Similarly, the material additions in the endcap are placed at constant z and have constant thickness as a function of radius. 123 Fig. 19 Sensitivity factor ∂∂relX/EX1/20 as a function of |η|, for material variations upstream of the PS for electrons, and for variations between the PS and L1 for unconverted photons with E 0 < 500 MeV. The shaded bands represent the systematic uncertainty due to the dependence of this quantity on the location of the material additions For each category and in a given |η| region, the amount of additional material X , expressed in terms of X 0 , is normalised to the relative shift induced in E 1/2 for electrons or photons respectively, obtaining a sensitivity factor ∂∂relX/EX1/20 . Figure 19 shows the sensitivity curve obtained from the various material distortions upstream of the PS, for electrons. The behaviour is approximately universal, and parameterised as a single curve. At small η, a 1 % relative change in E 1/2 corresponds to about 2.5 %X 0 . The sensitivity of unconverted photons with E 0 < 500 MeV to material between the PS and L1 is also shown; a 1 % relative change in E 1/2 corresponds to about 1.5 %X 0 , independently of η. This factor is scaled by the observed relative difference data of E E 1/2 1/2 between data and simulation after calibration corrections (see Fig. 14), yielding an estimate of the passivematerial offset with respect to the nominal simulation:  X/ X 0 = data E 1/2 ∂ X/ X 0 ∂rel E 1/2 . (6) The uncertainty on the material measurement receives data , reflecting the residual L1/L2 calcontributions from E 1/2 ibration uncertainty discussed in the previous section, and from ∂∂relX/EX1/20 . The intrinsic EM shower development modelling accuracy contributes to the latter; this item is evaluated by simulating high-E T electron samples and varying the associated Geant4 options to test refinements in the theoretical description of bremsstrahlung and photon conversion cross sections, as well as alternative electron multiple scattering models, and found to be ∼1 %. The residual sensitivity differences between the various material configurations contributes a systematic uncertainty of ∼10 % to the parameterisation. Eur. Phys. J. C (2014) 74:3071 Page 17 of 48 3071 0.3 ∫ ATLAS 0.2 1 -1 Base simulation ∫ ATLAS s=8 TeV, L dt = 20.3 fb -1 s=8 TeV, L dt = 20.3 fb Base simulation 0.5 ΔX/X0 ΔX/X0 0.1 0 0 -0.1 -0.5 Material integral up to PS -0.2 Material between PS and L1 Material integral up to L1 -1 -0.3 0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 |η| 0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2 2.2 2.4 |η| Fig. 20 Difference between the material estimate, X/ X 0 , from data and the nominal base simulation as a function of |η|. Left calorimeter material estimate obtained from data/MC comparisons of E 1/2 for unconverted photons, after calibration corrections. Right integrated esti- mate up to L1, obtained from data/MC comparisons for electrons, after calibration corrections; integrated estimate up to the PS, obtained by comparing electron and unconverted photon data. The error bars include statistical and systematic uncertainties Two categories of detector material are probed for |η| < 1.82: the integral between the interaction point and the PS, i.e. the sum of ID and cryostat material; and calorimeter material between the PS and L1. The former is obtained by comparing E 1/2 in the electron and unconverted photon data samples in order to subtract, from the electron probe, the influence of material after the PS. The latter is obtained by comparing E 1/2 for unconverted photons between data and simulation. For |η| > 1.82, only the total amount of material up to L1 is measured, by comparing E 1/2 for electrons in data and simulation. The ID material is considered known a priori, with an accuracy of 5 % from detailed monitoring and weighing during the construction and installation [4]. Studies using K S0 decays, secondary hadronic interactions and photon conversions were also performed [27,28], with no indication of ID material mis-modelling larger than 5 %. The ID material accuracy is combined with the measured material integral to derive an estimate for the cryostat material. The calorimeter material is measured without external inputs. remains in E 1/2 (see Fig. 14, bottom), translating into material discrepancies of at most 0.03X 0 . The measurement accuracy is about 0.03X 0 . In Fig. 20 (right), the data–MC material difference integrated up to L1, denoted X L1 and expressed in units of X 0 , results from the combination of the observed E 1/2 profile for electrons after calibration corrections (see Fig. 14, top) and the corresponding sensitivity curve (see Fig. 19). In the barrel, moderate features are observed, primarily a 0.2X 0 excess at |η| = 0.6, and a slight −0.1X 0 deficit between 0.8 < |η| < 1. In the endcap, the measurement is characterised by very strong excesses, up to 0.6–0.7X 0 , in the region 1.65 < |η| < 1.75, and around |η| = 1.9 because of an incomplete description of SCT cooling pipes. In the remaining part of the endcap, an overall bias of about 0.2X 0 is observed. In contrast, a deficit of about −0.5X 0 is observed within 1.55 < |η| < 1.6. The material bias integrated up to the PS, X PS , is obtained after subtracting, from the above, material contributions located after the PS, i.e. X Calo . This is derived by comparing the electron and unconverted photon data. The features observed within the PS acceptance are very similar to X L1 , which indicates that the material biases are located upstream of the PS. For both integrated estimates, the measurement accuracy ranges from about 0.04X 0 to 0.06X 0 . 8.2 Material determination The difference between the calorimeter material estimate from data and simulation, as obtained from the comparison of E 1/2 for unconverted photons after calibration corrections, is summarised in Fig. 20 (left). The statistical uncertainty in the measurement is dominated by the size of the unconverted photon control samples. Systematic uncertainties come from the accuracy of the material sensitivity calibration, the finite size of the MC sample, and from the residual sensitivity of unconverted photons to passive-material variations upstream of the PS. After calibration corrections, no significant bias 8.3 Improvements to the ATLAS material simulation This section presents the detector simulation improvements implemented following the results obtained in the previous section. Given the absence of significant biases in X Calo , the data suggest the need to implement in the simulation material modifications upstream of the PS. Most of the discrepancies correspond to areas with a large amount of material from ser- 123 3071 Page 18 of 48 Eur. Phys. J. C (2014) 74:3071 4 3 2 3.5 ATLAS Simulation Base simulation Improved simulation 3 2.5 Base simulation Improved simulation X/X0 X/X0 2.5 ATLAS Simulation 1.5 1 0.5 0.5 0 0.8 0.6 0.4 0.2 0 -0.2 -0.4 0 0.8 0.6 0.4 0.2 0 -0.2 -0.4 ΔX/X0 ΔX/X0 1 2 1.5 0 0.5 1 1.5 2 2.5 0 0.2 0.4 0.6 0.8 |η| Fig. 21 Amount of material traversed by a particle, X/ X 0 , as a function of |η|, for the base simulation and including the corrections based on calorimeter measurements, up to the ID boundaries (left), and between 1.2 1.4 1.6 1.8 the ID boundaries and the PS (right). The lower panels indicate the difference between the improved and the base simulations 3 16 Services TRT SCT Pixel Beam-pipe ATLAS Simulation 2.5 Up to calorimeter Up to presampler ATLAS Simulation 14 12 10 X/X0 2 X/X0 1 |η| 1.5 8 6 1 4 0.5 0 2 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 |η| 0 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 |η| Fig. 22 Amount of material traversed by a particle, X/ X 0 , as a function of |η|, in the improved simulation, up to the ID boundaries (left), and up to the PS and the EM calorimeter (right). The contributions of the different detector elements, including the services and thermal enclosures are shown separately by filled colour areas vices between the ID active area and the calorimeter cryostat. The corrections were implemented in an effective way, adding material in the most discrepant areas and in amounts corresponding to the measurement. The modifications to the detector material description are illustrated in Fig. 21. The total amount of detector material within the ID boundaries, and up to the active calorimeter are illustrated in Fig. 22 for the improved simulation. After implementation and validation of the improved simulation, the Z → ee samples were resimulated, and the E 1/2 data/MC comparisons repeated. The difference between the material estimate from data and the improved simulation is summarised in Fig. 23. As can be seen, the improved simulation behaves as expected in most of the acceptance: the overall discrepancy in the endcap has disappeared, as well as the strong peak around |η| = 1.9. The deficit within 1.5 < |η| < 1.6 remains, as it has not been addressed. In the barrel, the excess at |η| = 0.6 has been halved. The residual passive-material uncertainties in this improved simulation are presented in Fig. 24. Where no significant excess or deficit remains, the measurement uncertainty is given by the L1/L2 calibration uncertainty, and the sensitivity curves’ systematic uncertainties. When the residual discrepancy is larger than the measurement uncertainty, the size of the discrepancy is taken as the final uncertainty. No measurement was performed for 1.37 < |η| < 1.52; in this region the uncertainty on the material upstream of L1 is estimated to be ∼0.4X 0 , following Ref. [3]. The E 1/2 modelling systematic uncertainties summarised in Sect. 7 are considered correlated across η, separately in the barrel and endcap calorime- 123 Eur. Phys. J. C (2014) 74:3071 1 Page 19 of 48 3071 ∫ ATLAS 0.12 Uncertainty (X0) Improved simulation 0.5 ΔX/X0 0.14 s=8 TeV, Ldt = 20.3 fb-1 ATLAS 0 -0.5 Material integral up to PS ∫ -1 s=8 TeV, Ldt = 20.3 fb Material between PS and L1 Total Total correlated LAr modelling 0.1 0.08 0.06 0.04 0.02 Material integral up to L1 -1 0 0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2 2.2 2.4 0 0.2 0.4 0.6 0.8 1 |η| 1.4 1.6 1.8 ∫ s=8 TeV, Ldt = 20.3 fb-1 0.8 ATLAS 0.7 Material integral up to PS Total Correlated 0.6 0.5 0.4 0.3 0.2 0.1 0 0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 |η| 0.9 Uncertainty (X0) ters. Among these, the L1 gain systematic uncertainty only affects the measurement of the material integral up to L1, for |η| > 1.8. The Geant4 systematic uncertainties are fully correlated across η. The data-driven components of the material determination are estimated in bins of size η = 0.2, and the corresponding uncertainties are uncorrelated beyond this range. The MC-based energy calibration described in Sect. 5 is applied using the new detector description, to reoptimise the energy response in the endcap, where significant amounts of passive material were added in the simulation. The resulting MC calibration constitutes, together with the energy corrections described in Sects. 6 and 7, the basis of the absolute scale determination presented in the next section. Uncertainty (X0) 0.9 Fig. 23 Difference between the material estimate, X/ X 0 , from data and the improved simulation as a function of |η|. The integrated material estimate up to L1 is obtained from data/MC comparisons for electrons, after L1/L2 calibration corrections; the integrated estimate up to the PS is obtained by comparing electron and unconverted photon data. The error bars include statistical and systematic uncertainties 1.2 |η| 0.8 ATLAS 0.7 Material integral up to L1 0.6 Total Total correlated LAr modelling L1 Gain 0.5 ∫ -1 s=8 TeV, Ldt = 20.3 fb 0.4 0.3 0.2 9 Energy scale and resolution determination with electrons from Z → ee decays As shown in Sect. 6, no significant mis-calibration is observed as a function of φ, in a given η region. The residual non-uniformity is at the level of 0.75 % or better as illustrated in Fig. 8, matching the design constant term of 0.7 %. Furthermore, the energy response is shown in Figs. 9 and 10 to be stable with time at the level of 0.05 %. Consequently, the absolute scale determination is carried out as a function of η only, and independently of time and azimuth. 9.1 Methodology The energy mis-calibration is defined as the difference in response between data and simulation, and is parameterised as follows: 0.1 0 0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2 2.2 2.4 |η| Fig. 24 From top to bottom uncertainty on the calorimeter material estimate, X Calo ; on the material integral up to the PS, X PS ; and on the material integral up to L1, X L1 . The LAr E 1/2 modelling, Geant4 and L1 gain systematic uncertainties are assumed correlated across η. The remaining part of the uncertainty is data driven and considered uncorrelated E data = E MC (1 + αi ) (7) where E data and E MC are the electron energy in data and simulation, and αi represents the departure from optimal calibration, in a given pseudorapidity bin labelled i. For Z → ee decays, the effect of electron mis-calibration on the electron pair invariant mass is 123 3071 Page 20 of 48 Eur. Phys. J. C (2014) 74:3071 140 800 ATLAS 700 s=8 TeV; Data α = 0.014 α=0 α = -0.012 ∫ Ldt=20.3 fb -1 600 120 100 80 500 χ2 Entries / 0.5 GeV 900 60 400 40 300 20 200 0 100 0 80 ATLAS -20 s=8 TeV; -40 82 84 86 88 90 92 94 96 98 100 -0.01 ∫ Ldt=20.3 fb -0.005 ATLAS 700 s=8 TeV; ∫ Data c=0 c = 0.019 c = 0.038 -1 Ldt=20.3 fb 600 0 0.01 100 80 60 400 40 300 20 200 0 ATLAS -20 100 s=8 TeV; -40 82 84 86 88 90 92 94 96 98 100 0 ∫ Ldt=20.3 fb -1 MC m idata j = m i j (1 + αi j ), (8) σE E MC ⊕ c. min Bottom left templates of m ee for different values of c, for a fixed value of α. Top right χ 2 as a function of α, for the energy scale fit. Bottom right χ 2 as a function of c, for the resolution fit σm m data ij = (9) The sampling term is assumed to be known to 10 % from test-beam studies [35]. For each (ηi , η j ) category, the relative electron and invariant mass resolutions satisfy σm m MC ij ⊕ ci j 1 σ E MC σE ⊕ ci ⊕ 2 E i E (ci ⊕ c j ) , ci j = 2 = neglecting second-order terms and assuming that the angle MC between the two electrons is perfectly known; m idata j and m i j are the invariant mass in data and simulation for an electron pair reconstructed in pseudorapidity bins i and j, and αi j the induced shift of the mass peak. Electron resolution corrections are derived under the assumption that the resolution curve is well modelled by the simulation up to a Gaussian constant term = χ2 /N = 30/39 c Fig. 25 The electron pair invariant mass distribution, m ee , for Z → ee candidates in data compared to MC templates for events with one electron within 1.63 < η < 1.74, and the other within 2.3 < η < 2.4. Top left templates of m ee for different values of α, for a fixed value of c. (αi + α j ) , αi j ∼ 2 c = 0.0197 ± 0.0023 0.005 0.01 0.015 0.02 0.025 0.03 0.035 0.04 mee [GeV] 123 0.005 120 500 data min 140 800 χ2 Entries / 0.5 GeV 900 σE E χ2 /N = 30/39 α mee [GeV] 0 80 α = -0.0002 ± 0.0007 -1 MC j ⊕ cj , (10) where ci j is the relative invariant mass resolution correction for (ηi , η j ). To determine the α and c parameters, histograms of the invariant mass are created from the simulation, including energy scale and resolution perturbations to the reconstruction-level quantities, in a range covering the expected uncertainty in narrow steps. The templates are built separately for the electron pseudorapidity configurations (ηi , η j ) and constitute a two-dimensional grid along (αi j , ci j ). The data are categorised accordingly. The optimal values, uncertainties and correlations of αi j and ci j are obtained by χ 2 minimisation, as illustrated in Fig. 25. The individual electron energy scales and resolution correc- ∫ s=8 TeV, Ldt = 20.3 fb-1 ATLAS 0.02 0 -0.02 4 3.5 3 2.5 2 1.5 1 0.5 0 Z resonance (total uncertainty) Total Stat. -2 -3 -0.04 0.06 0.05 -1.5 -1 -0.5 0 0.5 1 1.5 2 η Fig. 26 Top energy scale corrections α, defined as E data = (1+α)E MC and derived from Z → ee events using the template method, as a function of η. The corrections are defined with respect to the 2010 calibration scheme, and after uniformity and layer calibration corrections. The error bands include statistical and systematic uncertainties. Bottom statistical and total energy scale uncertainties, δα as a function of η tions are obtained by solving the system given by Eqs. (8) and (10). An alternative method relies on the same kinematical relations, but replaces the templates by a parameterisation of the Monte Carlo distributions, and performs a likelihood fit to the energy scales. The parameterisation is based on the convolution of a Breit–Wigner function and a Gaussian distribution; the energy scales are determined by minimising with respect to αi j the following likelihood:   N events mk − ln L i j − ln L tot = , (11) α +α 1+ i2 j k=1 where 0< i, j < Nregions , Nregions is the number of regions considered for the calibration, Nevents is the total number of selected events and L i j (M|αi , α j ) is the probability density function (PDF) quantifying the compatibility of an event with the expected Z boson line shape at the reconstruction level, when the two electrons fall in regions i and j. 9.2 Results and uncertainties The methods described above are applied to a sample of Z → ee decays, selecting two electrons in the final state, satisfying E T > 27 GeV, |η| < 2.47, 80 < m ee < 100 GeV and medium ID selection criteria. The η categories are defined as bins of size η = 0.2 in the barrel; a more complicated structure is defined in the endcap, according to the PS acceptance boundaries and the η-dependent HV settings. The results are summarised in Figs. 26 and 27, where the energy scale and the effective constant term corrections are illustrated as a function of η. The energy scale factors are defined with respect to the 2010 calibration results [3], which were implemented as cell-level energy corrections in coarse ∫ s=8 TeV, Ldt = 20.3 fb-1 ATLAS Z resonance Azimuthal non-uniformity 0.04 0.03 0.02 0.01 δ c (10 ) -3 Page 21 of 48 3071 Effective constant term, c 0.04 δ α (10 ) Energy correction, α Eur. Phys. J. C (2014) 74:3071 0 12 10 8 6 4 2 0 Total Stat. -2 -1.5 -1 -0.5 0 η 0.5 1 1.5 2 Fig. 27 Top effective constant term corrections c derived from Z → ee events using the template method, as a function of η. The values of c are symmetrised with respect to η = 0. The error bands include statistical and systematic uncertainties. The contribution from the response uniformity derived in Sect. 6 of the paper is included for comparison and is not symmetrised. Bottom statistical and total uncertainties on c, δc as a function of η η bins; the values obtained here reflect the reoptimisation of the OFC coefficients for the 2012 pile-up conditions, and the uniformity and layer calibration corrections performed ahead of the absolute scale determination and discussed in the previous sections. They are found to be symmetric with respect to η = 0 in the barrel; in the endcaps, similar patterns are observed for η > 0 and η < 0, up to an overall shift of about 1 % resulting from the slightly different LAr temperature in the two cryostats. The energy scale determination is accurate to 0.3 × 10−3 for |η| < 1.37, 2 × 10−3 for 1.37 < |η| < 1.82 and 0.5 × 10−3 for |η| > 1.82. The resolution corrections are about 0.8 % on average in the barrel, and about 1 % in the endcap, and are determined to be accurate on average to 0.3 and 0.5 %, respectively. At given |η|, the values of c are found to be statistically compatible for η > 0 and η < 0 and are symmetrised in Fig. 27. The uncertainty contributions are detailed below. The agreement of the energy scale between the template and likelihood methods is good, with an average difference of δα = 3.8 × 10−4 when the full η range is considered, and of 1.3 × 10−4 when the transition region (1.37 < |η| < 1.55) is discarded. The fitted constant terms agree within δc = 1.2 × 10−3 between the two methods. The intrinsic accuracy of the template method is tested by injecting known energy scale and resolution distortions into a simulation sample that is treated as the data. The corresponding α and c corrections are then derived by comparing the modified simulation to the templates, and compared to the injected values. No bias is found beyond the statistical accuracy of the test; systematic uncertainties of δα = 0.5 × 10−4 for the energy scales, and δc = 1.1 × 10−3 for the resolution corrections are assigned. 123 3071 Page 22 of 48 9.3 Data/MC comparison after corrections After all corrections, the dielectron mass distribution in data and simulation agree at the level of 1 % in the mass range 123 Entries / 500 MeV 3 Ratio to MC The sensitivity of the result to the event selections is studied by varying the electron identification criteria and the mass window used for the fit. Repeating the energy correction determination using electrons with tight ID selection criteria gives an average difference δα = 1.2 × 10−4 for the energy scales, and δc = 1.1 × 10−3 for the resolution corrections. Uncertainties on the efficiency corrections for trigger, identification and reconstruction can distort the invariant mass distribution and lead to a total uncertainty of about δα = 0.4×10−4 on the energy scales and δc = 0.3×10−3 on the resolution corrections. The impact of the choice of mass window is on average δα = 0.9×10−4 and δc = 0.9×10−3 . The dedicated tracking algorithm used for electrons provides momentum measurements at the interaction point and at the outer radius of the ID, denoted by (q/ p)IP and (q/ p)out respectively. The momentum lost by bremsstrahlung is quantified by defining f brem = 1 − (q/ p)IP /(q/ p)out , where values close to 0 select electrons which have lost a small fraction of their momentum. Repeating the analysis requiring f brem < 0.3 selects an electron sample with less bremsstrahlung than the inclusive sample, with an efficiency of about 50 %. The impact of this selection is δα = 6 × 10−4 and δc = 1.5 × 10−3 . Uncertainties induced by the general modelling of the signal process (pile-up, interaction point distribution, theoretical description of the Z lineshape) contribute δα = 0.4 × 10−4 and δc = 0.5 × 10−3 . Electroweak, top and multijet backgrounds constitute about 0.13 % of the selected Z boson sample. To propagate the corresponding uncertainty, the normalisation of the electroweak and top backgrounds is varied within the theoretical cross-section uncertainties, which are as large as 10 % depending on the channel, with an impact of δα = 0.3×10−4 and δc = 0.4 × 10−3 . The multijet background fraction is estimated by comparing the electron isolation distribution observed after all selections with the expected distributions for signal and multijet production [12]. The signal distribution is determined from the simulation, while the multijet distribution is determined from a jet-enriched sample obtained by selecting electron pairs passing only the loose identification criterion. The relative uncertainty of this determination is 50 % and contributes δα = 0.2 × 10−4 and δc = 0.1 × 10−3 . The uncertainties quoted above are averages; the values depend on pseudorapidity, with larger values in regions with a large amount of material upstream of the calorimeter and in the transition region between the barrel and endcap. The stability of the corrections with the energy is discussed in Sect. 11. Eur. Phys. J. C (2014) 74:3071 500 450 400 350 300 250 200 150 100 50 0 ×10 Calibrated data MC, uncorrected MC 1.1 1.05 1 0.95 0.9 80 ∫ s=8 TeV, Ldt = 20.3 fb-1 ATLAS Calibration uncertainty 82 84 86 88 90 92 94 96 98 100 mee [GeV] Fig. 28 Top electron pair invariant mass distribution for Z → ee decays in data and improved simulation. Energy scale corrections are applied to the data. The improved simulation is shown before and after energy resolution corrections, and is normalised to the number of events in data. Bottom ratio of the data and uncorrected MC distributions to the corrected MC distribution with the calibration uncertainty band 80 < m ee < 100 GeV, rising to 2 % towards the low end of the interval. The energy scale adjustment, followed by the resolution correction, are the main causes of the improved agreement with respect to that obtained with the previous calibration and simulation [3]. The jet, electroweak and top backgrounds contribute about 1.5 % near m ee = 80 and m ee = 100 GeV. Figure 28 shows the dielectron mass distribution for the data corrected with the energy scale factors and for the MC simulation with and without the resolution corrections. In addition the ratios of the corrected data and uncorrected MC distributions to the corrected MC distribution are illustrated together with the final calibration uncertainty. A slight excess persists at low mass, indicating that the energy tails in the data are not entirely modelled by the simulation, even after the calibration and detector geometry improvements described above. However, as shown in Fig. 28, this discrepancy lies within the quoted passivematerial uncertainty. Its impact on the energy scale and resolution corrections is covered by the systematic variations described in the previous section. 10 Summary of uncertainties common to electrons and photons The calibration uncertainty for electrons from Z boson decays is determined, at given pseudorapidity and for e(Z →ee)  ∼ 40 GeV, by the accuracy of the Z -based calE T ibration described in the previous section. Other effects are generally energy and particle-type dependent and can be written as follows: Eur. Phys. J. C (2014) 74:3071 e,γ δ Ei (E T , η) = e,γ Ei (E T , η) − Page 23 of 48 3071 e(Z →ee) E ie (E T , η) (12) A given source of uncertainty i changes the energy scale by e,γ E i (E T , η), which is a function of E T and η and depends on particle type. The Z -based effective calibration absorbs e(Z →ee)  and leaves the the effect for electrons with E T = E T e,γ residual uncertainty δ E i (E T , η). Because of this subtrace,γ tion, δ E i (E T , η) can change sign as a function of E T . The gain dependence of the energy response is measured in data by comparing the Z peak position for electron clusters with all L2 cells recorded in HG to electrons with at least one cell recorded in MG. The probability of an electron or photon cluster to contain at least one MG cell increases smoothly with energy in a given η range: it is parameterised using simulated Z → ee and H → γ γ samples, and is then validated using Z → ee events from data. The parameterisation is used to correct for the effect in data, and the full size of the correction is taken as uncertainty. As a separate effect, the energy pedestal of electron and photon clusters is verified by comparing pile-up only events in data and simulation. An average offset of about 15 MeV is found, depending on η. The induced energy non-linearity is negligible at high energy but can reach 0.1 % for E T ∼ 10 GeV and is counted as a separate systematic uncertainty. The impact of the PS and L1/L2 calibration uncertainties on the reconstructed particle energy depends on the fractional energies of the cluster carried in those layers, f PS and f L2 . The energy and pseudorapidity dependence of f PS and f L2 is parameterised for electrons and photons using the simulation, and the uncertainty is given by the product of these energy fractions and the corresponding layer calibration uncertainties, at given E T and η. An additional uncertainty is assigned to the intrinsic accuracy of EM shower development simulation, by varying physics modelling options in Geant4. The ID, Cryo and Calo material uncertainties are propagated after comparing the energy response in samples simulated with modified and nominal detector material. The simulation modifications follow the description in Sect. 8.1; the corresponding response differences are scaled to the actual material measurement uncertainties, yielding the energy response uncertainties. The dominant sources of uncertainty are illustrated in Fig. 29 for electrons and unconverted photons, for |η| < 0.6 and 5 < E T < 200 GeV. All curves correspond to an upward variation of the considered source of uncertainty by one standard deviation; the effect of this variation can change sign as a function of E T , as discussed above. For electrons, the layer calibration uncertainties reach about 0.15 % at low E T , are minimal for E T ∼ 40 GeV, and rise to about 0.05 % towards high energy. For unconverted photons, the layer uncertainties are largest at high energy, reaching about 0.1 %. The uncertainty related to the HG/MG transition contributes above E T ∼ 50 GeV, and reaches 0.3 % at high transverse energy. A deficit of passive material in the simulation induces a drop in the energy scale towards low E T ; in this pseudorapidity region, the drop is largest for cryostat material and reaches −0.3 % at E T = 5 GeV. After the Z -based calibration, the same material deficit induces an overestimate of the energy response for unconverted photons by about 0.05 %, regardless of the passive material type. The energy dependence of this effect is negligible for unconverted photons and the corresponding uncertainties are considered independent of E T . Other sources of uncertainty are subleading and not discussed here explicitly. All sources are considered as independent and their sum in quadrature defines the total uncertainty at given E T and η. Tables 2, 3, 4, 5 and 6, show the uncertainty contributions discussed above as a function of pseudorapidity, and fixed values of E T . For electrons, E T = 11 and 40 GeV are typical of J/ψ → ee and Z → ee decays, respectively; E T = 200 GeV illustrates the asymptotical behaviour of the uncertainty. For photons, E T = 60 GeV is typical for H → γ γ decays with m H ∼ 125 GeV. The uncertainty model developed and summarised here is expected to be valid up to E T ∼ 500 GeV. At these energies, the contribution of the third calorimeter layer to the energy measurement is enhanced, and a significant fraction of electrons and photons are recorded in low gain. These aspects are not addressed in this paper. 11 Electron calibration cross-checks At this point, the electron energy scale is fully specified; after all corrections are applied, the energy response is expected to be linear and uniform. The objective of the present section is to test the extrapolation to different E T regimes using additional probes. 11.1 Energy scale from J/ψ → ee The results presented here are based on the J/ψ → ee sample described together with the selection criteria in Table 1, and consisting of about 185K events. After selections [12], the average electron transverse energy is E T = 11 GeV, making this sample a useful test of the energy response in the low energy range where electrons from Z decays are not available. The invariant mass distribution of the events selected in the data sample shows a sizeable background contribution and a hint of the ψ(2S) resonance. To disentangle these contributions, the Monte Carlo J/ψ signal is parameterised by an empirical function taking into account the Gaussian core of the peak and the non-Gaussian tails. The parameterised signal is used as input for a fit to the data to extract the combinatorial background, parameterised as a second-order 123 3071 Page 24 of 48 Eur. Phys. J. C (2014) 74:3071 0.004 0.004 Signed uncertainty 0.003 0.002 0.001 0 -0.001 -0.002 0.002 0.001 0 -0.001 -0.002 ATLAS -0.003 -0.004 ATLAS -0.003 Electrons, |η|<0.6 20 40 Z→ee calibration ID material Cryo material Calo material 0.003 Signed uncertainty Z→ee calibration αPS, data uncertainty α1/2, data uncertainty α1/2, μ→e extrap. L2 Gain 60 80 Electrons, |η|<0.6 -0.004 100 120 140 160 180 200 20 40 60 80 E T [GeV] 0.004 0.004 Signed uncertainty 0.002 0.001 0 -0.001 -0.002 -0.004 ATLAS Unconverted photons, |η|<0.6 20 40 60 80 0.002 0.001 0 -0.001 -0.002 -0.003 100 120 140 160 180 200 Z→ee calibration ID material Cryo material Calo material 0.003 Signed uncertainty Z→ee calibration αPS, data accuracy α1/2, data accuracy α1/2, μ→e extrap. L2 Gain 0.003 -0.003 ATLAS Unconverted photons, |η|<0.6 -0.004 20 40 60 ET [GeV] Table 2 Summary of energy scale systematic uncertainty contributions from sources common to electrons and photons, estimated for electrons with E T = 11 GeV, in % 80 100 120 140 160 180 200 ET [GeV] Fig. 29 The E T dependence of the dominant calibration systematic uncertainties for |η| < 0.6, for electrons and unconverted photons. The curves show the effect on the energy scale of upward variations of the listed sources of uncertainty; depending on source and particle type, the effect can change sign as a function of E T . Left uncertainties from the relative response of L1 and L2 (data-driven uncertainties of the PS and L1/L2 response measurements; uncertainty in the application of the muon-based measurement to electrons; L2 HG/MG uncertainty). Right passive-material uncertainties (ID, cryostat and calorimeter material) Electrons, E T = 11 GeV |η| range 0–0.6 0.6–1 1–1.37 1.37–1.55 1.55–1.82 1.82–2.47 Z → ee calibration 0.03 0.04 0.08 0.22 0.22 0.05 Gain, pedestal 0.09 0.09 0.07 0.00 0.09 0.24 Layer calibration 0.15 0.19 0.14 0.16 0.13 0.19 ID material 0.03 0.03 0.31 0.88 0.33 0.10 Other material 0.12 0.38 0.58 0.20 1.00 0.15 Total 0.22 0.44 0.69 0.94 1.09 0.36 polynomial, and the ψ(2S) contribution. The J/ψ peak position is unconstrained, and the ψ(2S) resonance is assumed to be identical to that of the J/ψ signal, up to a scaling of the mass and the corresponding expected change in resolution. The events are categorised as a function of electron pseudorapidity as in Sect. 9. For each (ηi , η j ) category, the electron pair invariant mass PDF, L i j (m ee ), is built from the fitted signal and background components. The electron energy 123 100 120 140 160 180 200 E T [GeV] scale factors αi are extracted using a simultaneous fit using the likelihood function given in Eq. (11). The statistical uncertainty on the electron energy scale extraction amounts to 0.1–0.2 %, depending on pseudorapidity. The main source of systematic uncertainty is induced by the imperfect modelling of the electron isolation. The J/ψ sample results from direct production and from b → J/ψ decays; in the latter process, the electrons are produced in Eur. Phys. J. C (2014) 74:3071 Table 3 Summary of energy scale systematic uncertainty contributions from sources common to electrons and photons, estimated for electrons with E T = 40 GeV, in % Table 4 Summary of energy scale systematic uncertainty contributions from sources common to electrons and photons, estimated for electrons with E T = 200 GeV, in % Table 5 Summary of energy scale systematic uncertainty contributions from sources common to electrons and photons, estimated for unconverted photons with E T = 60 GeV, in % Table 6 Summary of energy scale systematic uncertainty contributions from sources common to electrons and photons, estimated for converted photons with E T = 60 GeV, in % Page 25 of 48 3071 Electrons, E T = 40 GeV |η| range 0–0.6 0.6–1 1–1.37 1.37–1.55 1.55–1.82 1.82–2.47 Z → ee calibration 0.03 0.04 0.08 0.22 0.22 0.05 Gain, pedestal 0.00 0.00 0.00 0.00 0.02 0.01 Layer calibration 0.01 0.01 0.01 0.00 0.00 0.01 ID material 0.00 0.00 0.01 0.00 0.00 0.00 Other material 0.00 0.01 0.02 0.00 0.02 0.00 Total 0.03 0.04 0.08 0.22 0.22 0.05 1.37–1.55 1.55–1.82 1.82–2.47 Electrons, E T = 200 GeV |η| range 0–0.6 0.6–1 1–1.37 Z → ee calibration 0.03 0.04 0.08 0.22 0.22 0.05 Gain, pedestal 0.21 0.36 0.40 0.00 2.14 0.61 Layer calibration 0.15 0.18 0.16 0.18 0.18 0.21 ID material 0.00 0.06 0.07 0.78 0.17 0.06 Other material 0.06 0.17 0.35 0.20 0.63 0.07 Total 0.27 0.45 0.57 0.85 2.25 0.65 Unconverted photons, E T = 60 GeV |η| range 0–0.6 0.6–1 1–1.37 1.55–1.82 1.82–2.47 Z → ee calibration 0.03 0.04 0.08 0.16 0.05 Gain, pedestal 0.03 0.02 0.01 0.89 0.55 Layer calibration 0.15 0.20 0.20 0.25 0.26 ID material 0.06 0.12 0.19 0.07 0.12 Other material 0.09 0.17 0.40 0.96 0.09 Total 0.19 0.31 0.50 1.35 0.63 1.55–1.82 1.82–2.47 Converted photons, E T = 60 GeV |η| range 0–0.6 0.6–1 1–1.37 Z → ee calibration 0.03 0.04 0.08 0.22 0.05 Gain, pedestal 0.03 0.02 0.01 0.86 0.06 Layer calibration 0.03 0.05 0.06 0.11 0.05 ID material 0.03 0.10 0.09 0.15 0.05 Other material 0.03 0.04 0.13 0.37 0.05 Total 0.18 0.34 0.50 1.00 0.23 the vicinity of jets, which contribute to the measured electron cluster energy. The uncertainty on the relative fractions of the two processes and on the modelling of the jet contribution to the electron energy contributes an uncertainty of 0.2 %. The fit results are shown in Fig. 30, and are compared to the expected uncertainties, composed of Z scale uncertainties, PS and L1/L2 intercalibration, and passive-material uncer- tainties extrapolated to E T = 11 GeV. The uncertainties on the energy scales determined from the J/ψ sample include the contributions discussed above. Satisfactory agreement is obtained, although the J/ψ results tend to be higher than the Z ones by about one standard deviation. The residual differences in the central region can be explained by an imperfect calibration of the cell response, associated to a difference of the read-out pedestals in physics and calibration runs. This 123 3071 Page 26 of 48 Eur. Phys. J. C (2014) 74:3071 0.02 Sects. 9, 11.1 are repeated, now categorising the electrons in broad intervals of |η|, with the following boundaries: 0.015 0.01 – |η| : 0 – 0.6 – 1 – 1.37 – 1.55 – 1.82 – 2.47. 0.005 In addition, the Z → ee sample is subdivided in electron E T intervals: Δα 0 -0.005 -0.01 -0.015 -0.02 – E T : 27 – 35 – 42 – 50 – 100 GeV. ∫ s=8 TeV, Ldt = 20.3 fb-1 ATLAS -2 -1.5 -1 -0.5 0 0.5 1 1.5 2 η 20000 18000 16000 14000 12000 10000 8000 6000 4000 2000 0 Ratio to MC Entries / 50 MeV Fig. 30 Energy scale factors α obtained after Z -based calibration from the J/ψ sample, as a function of the electron pseudorapidity. The band represents the calibration systematic uncertainty. The error bars on the data points represent the total uncertainty specific to the J/ψ → ee analysis ATLAS mee [GeV] 1.1 1.05 1 0.95 0.9 2 2.2 2.4 2.6 2.8 3 3.2 3.4 3.6 3.8 4 mee [GeV] Fig. 31 Invariant mass distribution of the electron pair corresponding to the J/ψ selection in data and simulation, after the energy corrections described in the text are applied to the electron candidates in data. A background component is determined from data and added to the simulated J/ψ resonance small bias is understood as resulting from a different setting of the electronics configuration used in both cases. In the region 1 < |η| < 1.82, the differences are most probably related to residual uncertainties in the detector material description. Figure 31 shows the electron pair invariant mass distribution in data and MC simulation, and the data/MC ratio as a function of m ee after energy corrections. The corrected data and the simulation agree within uncertainties across the mass window used in the analysis. 11.2 Energy linearity in Z events and overall electron calibration accuracy Finally, a study of the energy dependence of the calibration is performed. The Z → ee and J/ψ → ee analyses of 123 12 Photon-specific uncertainties 12.1 Conversion reconstruction inefficiency and fake conversions Calibrated data MC + background ∫ s=8 TeV, Ldt = 20.3 fb-1 The analysis is performed after applying all corrections derived above, so that the energy scale corrections derived here are expected to be close to zero and constant. The results are shown in Fig. 32. In all cases, the resulting energy scales lie within the calibration systematic uncertainty envelopes. The fraction of photons that convert to electron–positron pairs before reaching the calorimeter is directly connected to the amount of material upstream. The efficiency to reconstruct the corresponding tracks and match them to clusters is close to unity for conversions in the innermost layers of the detector and drops at larger radii, in the region instrumented by the TRT. The energy of true converted photons reconstructed as unconverted is typically underestimated by about 2 %, depending on pT , η and the radius of the conversion. On the other hand, wrong associations between tracks induced by pile-up interactions or fake tracks and clusters lead to “fake conversions” that induce around 2% overestimation of the energy. This effect is also more frequent for tracks reconstructed in the TRT due to the imprecise measurement of η. Both effects impact the absolute photon energy scale if the efficiency and fake rates are imperfectly described by the simulation. Systematic uncertainties associated with these quantities were estimated by comparing the conversion rates in data and MC simulation, and using a template method based on the ratio E 1/2 . The latter exhibits a different behaviour for photons that do or do not convert before the calorimeter and therefore is sensitive to the “true” conversion status of the photon. By combining the true and reconstructed conversion status, one can determine the reconstruction efficiency and fake rate in data. The method can also provide an estimate of the material upstream and could be used in the future to constrain this quantity. The study was performed in four |η| bins (0–0.6, 0.6–1.37, 1.52–1.81, 1.81–2.37) using the same event selection as typically adopted by the H → γ γ analysis [36]. Events with Eur. Phys. J. C (2014) 74:3071 Page 27 of 48 3071 0.02 0.015 0.02 J/ψ → ee Electrons, |η|<0.6 0.015 Z → ee Calibration uncertainty 0.01 Δα Δα Calibration uncertainty 0.005 0 0 -0.005 -0.005 -0.01 -0.01 -0.02 Z → ee 0.01 0.005 -0.015 ∫ 10 20 -0.015 -1 s=8 TeV, Ldt =20.3 fb ATLAS 30 40 50 60 70 80 90 -0.02 100 ∫ 10 20 30 40 0.015 Z → ee Calibration uncertainty Δα Δα 100 Z → ee Calibration uncertainty -0.005 -0.01 -0.01 ∫ 10 20 -0.015 s=8 TeV, Ldt =20.3 fb-1 ATLAS 30 40 50 60 70 80 90 -0.02 100 ∫ s=8 TeV, Ldt =20.3 fb-1 ATLAS 10 20 30 40 ET [GeV] 50 60 70 80 90 100 ET [GeV] 0.02 0.02 J/ψ → ee Electrons, 1.55<|η|<1.82 0.015 Z → ee Calibration uncertainty 0.01 J/ψ → ee Electrons, 1.82<|η|<2.47 Z → ee Calibration uncertainty 0.01 0.005 Δα 0.005 Δα 90 0 -0.005 0 0 -0.005 -0.005 -0.01 -0.01 -0.02 80 0.005 0 -0.015 70 J/ψ → ee Electrons, 1.37<|η|<1.55 0.01 0.005 0.015 60 0.02 J/ψ → ee Electrons, 1<|η|<1.37 0.01 -0.02 50 E T [GeV] 0.02 -0.015 -1 s=8 TeV, Ldt =20.3 fb ATLAS E T [GeV] 0.015 J/ψ → ee Electrons, 0.6<|η|<1 ∫ 10 20 -0.015 s=8 TeV, Ldt =20.3 fb-1 ATLAS 30 40 50 60 70 80 90 100 ET [GeV] -0.02 ∫ s=8 TeV, Ldt =20.3 fb-1 ATLAS 10 20 30 40 50 60 70 80 90 100 ET [GeV] Fig. 32 Energy scale factors α obtained after Z -based calibration from the J/ψ and the E T -dependent Z → ee analyses, as function of E T in different pseudorapidity bins. The band represents the calibration systematic uncertainty. The error bars on the data points represent the total uncertainty specific to the cross-checking analyses two photon candidates satisfying tight identification criteria based on calorimeter shower shapes and both track- and calorimeter-based isolation were considered. The ratio of the transverse momenta of the photons to the diphoton invariant mass, pT /m γ γ , was required to be above 0.35 and 0.25 for the leading and subleading photons, respectively, with 105 < m γ γ < 160 GeV. The study was limited to the leading photon of each event in order to limit contamination by jets misidentified as photons, estimated to be ∼10 %. This jet background is subtracted in each E 1/2 bin using a sideband method based on the identification and isolation criteria [16]. The contribution of Drell–Yan events was estimated to be ∼0.3 % using MC simulation. Systematic uncertainties associated with imperfect knowledge of E 1/2 and the material upstream were propagated to the templates and the expected conversion rate in each bin. 123 3071 Page 28 of 48 Table 7 Impact on the energy scale of unconverted (converted) photons from the additional inefficiency (fake rate) in four pseudorapidity bins, in % Table 8 Difference between out-of-cluster energy loss for electrons and photons, (γ − e), in % Eur. Phys. J. C (2014) 74:3071 Uncertainty |η| < 0.6 0.6 ≤ |η| < 1.37 1.52 ≤ |η| < 1.81 1.81 ≤ |η| < 2.37 Inefficiency 0.02 0.03 0.10 0.02 Fake rate 0.01 0.06 0.06 0.03 |η| < 0.8 0.8 ≤ |η| < 1.37 1.52 ≤ |η| < 2.37 (γ − e), converted 0.16 ± 0.11 0.46 ± 0.10 0.19 ± 0.10 (γ − e), unconverted 0.03 ± 0.04 0.10 ± 0.06 0.05 ± 0.04 Particle type The results point to inefficiencies and fake rates that exceed by up to a few percent the predictions from MC simulation. The impact on the energy scale of unconverted (converted) photons from the additional inefficiency (fake rate) is shown in Table 7. It is typically around few 10−4 depending on pT and η, and reaches 10−3 in the bin 1.52 < |η| < 1.81 around E T = 60 GeV. 12.2 Lateral leakage mis-modelling Electrons and photons deposit about 6 % of their energy outside of the cluster used in the reconstruction, depending on pseudorapidity and particle type. Although this effect is to first order taken into account by the MC calibration, a calibration bias could appear in the case of imperfect modelling of lateral shower development, as the energy loss would be different in data and simulation. The energy scale factors obtained from the Z -based effective calibration described in Sect. 9 absorb such discrepancies. The energy dependence of the difference between data and simulation for electron lateral leakage was investigated and found to be negligible. Therefore the only component yet to be determined is the mis-modelling difference between electrons and photons. The Z → γ and Z → ee samples are used to estimate this difference. The energy of the decay electrons and radiative photons in the nominal cluster size is compared to the energy found in a larger window of size η × φ = 7 × 11 cells defined around it, using only cells in L2. The normalised difference between electrons and photons,  E 7×11 − E nom data (γ − e) = E nom  E 7×11 − E nom MC − , (13) E nom is estimated for three pseudorapidity intervals, separating unconverted and converted photons. The effect of the mis-modelling of photon conversion reconstruction is tested by correcting the fraction of converted photons in simulation according to the results of Sect. 12.1, and (γ − e) is evaluated with and without 123 this correction. Table 8 shows the most conservative values obtained for each bin and photon type according to this procedure. The most significant effects found are (0.46 ± 0.10) % for converted photons within 0.8 < |η| < 1.37, and (0.10 ± 0.06) % for unconverted photons in the same pseudorapidity bin. The systematic uncertainty on the photon energy scale related to this effect is defined in each bin as the larger of (γ − e) and its uncertainty. This uncertainty is assumed to not depend on the photon transverse energy. 13 Photon calibration cross-checks The energy scale factors extracted in Sect. 9 are expected to be valid for electrons and photons. Their universality is tested using photons from radiative Z decays in the electron and muon channels, separately for unconverted, one-track and two-track converted photons. A first selection requires a large-angle separation between the radiative photon and the leptons and is applied in the electron and muon channels, and for converted and unconverted photons; a sample of unconverted collinear photons is also selected in the muon channel [37]. The event selection is detailed in Table 1; the photon purity in the various samples is estimated to range between 97 and 99 %. Figure 33 shows the three-body invariant mass distributions for converted and unconverted photons in data and MC simulation for large-angle Z → γ events in the electron and muon channels after all energy corrections are applied. Residual mis-calibrations between data and MC simulation are parameterised following E idata = (1 + αi )E iMC , similar to the procedure applied to electrons from Z decays in Sect. 9. Here, E iMC and E idata are photon energies in region i for MC simulation and data respectively, and αi measures the residual photon energy mis-calibration. For each αi applied to data, the three-body invariant mass m(γ (αi ))data is recomputed; its agreement with MC simulation is quantified using a double ratio method, R(αi ) = m(γ (αi ))data  / m()data  , m(γ )MC  / m()MC  (14) Eur. Phys. J. C (2014) 74:3071 Page 29 of 48 3071 1000 Events / GeV 800 700 600 500 400 ∫ ATLAS ∫ ATLAS s = 8 TeV, Ldt = 20.3 fb Converted photons Z→μμγ , data Z→μμγ , MC Z→eeγ , data Z→eeγ , MC 300 200 2000 1500 -1 s = 8 TeV, Ldt = 20.3 fb 2500 Events / GeV 900 3000 -1 Unconverted photons Z→μμγ , data Z→μμγ , MC Z→eeγ , data Z→eeγ , MC 1000 500 100 0 60 70 80 90 100 110 120 0 60 70 80 m llγ [GeV] 90 100 110 120 m llγ [GeV] γ Fig. 33 Invariant mass distributions in data and simulation, for largeangle Z → γ events with converted (left) and unconverted photons (right) in the electron and muon channels, as described in the legend, for R(, γ ) > 0.4 and E T > 15 GeV. Energy corrections are applied. The MC simulation is normalised to the number of events in data where m(γ ) and m() are the mean values of the three-body and two-body invariant masses in the radiative and non-radiative samples, respectively. Taking the ratio of m(γ (αi )) to m() in the R(αi ) numerator suppresses the lepton energy scale uncertainties; normalising this ratio to the MC expectation removes possible biases due to the different lepton kinematics in Z →  and Z → γ events. The value of αi that provides the best agreement in the distributions with R(αi ) = 1 defines the photon energy scale. The photon energy scales are separately derived for non-collinear Z → eeγ and Z → μμγ events for both unconverted and converted photons, while collinear Z → μμγ events are only used for unconverted photons. The energy scales from the different event topologies are then combined. Several sources of systematic uncertainty are considered in this study: background contamination, fit range, muon momentum scale and resolution in the Z → μμ channel and electron energy scale and resolution in the Z → ee channel. The total systematic uncertainty is of the order of 0.1 % while the statistical uncertainty ranges between 0.2 and 1.5 % depending on the pseudorapidity and on the photon conversion type. Figure 34 shows the combined photon energy scales as a function of both η and E T , separately for unconverted, singleand double-track converted photons. The bands around zero represent the calibration systematic uncertainty, including contributions discussed in Sects. 10 and 12. The measured photon energy scales agree with the expectation within uncertainties. straint on the total resolution at given η and for E Te(Z →ee)  ∼ 40 GeV, the average transverse energy of electrons from Z decays. The resolution corrections c are derived in Sect. 9 as an effective constant term to be added in quadrature to the expected resolution. However, as is the case for the energy scales, c absorbs the potential mis-modelling of the resolution sampling term, the electronics noise term, the asymptotic resolution at high energy, and the effect of passive material upstream of the calorimeter. Uncertainties related to these sources thus reappear when considering different energies or particle types. The calorimeter intrinsic resolution, defined as the expected resolution in the absence of upstream material and with perfect √ response uniformity, is a function of η and scales as 1/ E. A 10 % uncertainty is assumed from test-beam studies [35] and from simulation predictions obtained by varying the physics modelling options in Geant4. Taking into e(Z →ee)  ∼ account that the resolution is constrained at E T 40 GeV, the uncertainty int on the squared resolution induced by a 10 % relative increase in the intrinsic resolution is: 14 Resolution accuracy The main way to probe the resolution in data is provided by the study of the Z resonance width, which provides a con- 2 2 int (E, η) = (1.1 − 1) × [σint (E, η) e(Z →ee) 2 − σint (E T  × cosh η, η)] (15) where σint (E, η) is the intrinsic resolution (in units of GeV), and int can be positive or negative depending on particle type and energy. Equation (15) is obtained by varying the sampling term by 10 % in Eq. (2) and requiring that the total resolution is unchanged at E T ∼ 40 GeV. The resolution noise term scales as 1/E T for pile-up noise and 1/E for electronic noise, and mostly matters at low energy. It receives contributions from the read-out electronics and pile-up. A measurement of the total noise affecting electron and photon clusters is performed by comparing pile- 123 3071 Page 30 of 48 Eur. Phys. J. C (2014) 74:3071 0.025 0.025 Unconverted photons 0.02 0.015 0.01 0.01 0.005 0.005 0 -0.005 Data Calibration uncertainty 0 -0.005 -0.01 -0.01 -0.015 -0.02 Unconverted photons 0.015 Δα Δα 0.02 Data Calibration uncertainty ATLAS 0 0.2 0.4 0.6 0.8 s=8 TeV; 1 ∫ L dt = 20.3 fb -1 1.2 1.4 1.6 1.8 2 -0.015 -0.02 2.2 ATLAS s=8 TeV; 10 20 30 0.02 Converted photons (1 track) 0.02 Converted photons (1 track) 0.015 Data Calibration uncertainty 0.015 Data Calibration uncertainty 0.01 0.01 0.005 0.005 Δα Δα 60 0.025 0 -0.005 0 -0.005 -0.01 -0.01 -0.015 ATLAS 0 0.2 0.4 0.6 0.8 s=8 TeV; 1 ∫ L dt = 20.3 fb -1 1.2 1.4 1.6 1.8 2 -0.015 ATLAS -0.02 10 15 2.2 ∫ s=8 TeV, Ldt = 20.3 fb-1 20 25 |η| 0.04 30 35 40 45 50 55 60 ET [GeV] 0.04 Converted photons (2 tracks) Data Calibration uncertainty 0.03 0.03 0.02 0.02 0.01 0.01 Δα Δα 50 ET 0.025 0 -0.01 Converted photons (2 tracks) Data Calibration uncertainty 0 -0.01 -0.02 -0.03 -1 40 |η| -0.02 ∫ L dt = 20.3 fb ATLAS 0 0.2 0.4 0.6 0.8 s=8 TeV; 1 ∫ L dt = 20.3 fb 1.2 1.4 1.6 1.8 -1 2 2.2 -0.02 -0.03 10 ∫ s=8 TeV, Ldt = 20.3 fb-1 ATLAS 15 20 25 |η| Fig. 34 Combined photon energy scale factors α obtained after Z based calibration as a function of |η| (left) and E T (right), for unconverted, one-track converted and two-track converted photons. The band up-only events in data and simulation. Random clusters of the size used for electrons and photons are drawn over η, φ, and the noise σnoise is defined as the spread of the cluster transverse energy distribution. The noise systematic uncertainty δnoise is defined as the difference in quadrature between σnoise in data and simulation. An uncertainty of δnoise = 100 MeV is found across η, apart for 1.52 < |η| < 1.82 where ±200 MeV is appropriate. Its impact is 123 30 35 40 45 50 55 60 ET [GeV] represents the calibration systematic uncertainty. The error bars on the data points represent the total uncertainty specific to the Z → γ analyses noise (E, η) = ET 2  δnoise (η) ET  2 − 2 δnoise (η) e(Z →ee) E T  . (16) The impact of detector material uncertainty on the resolution is treated as follows. Assuming the ID, cryostat and calorimeter material uncertainties discussed in Sect. 8, Z → ee samples are simulated with corresponding geometry distortions. The distorted geometry samples are used as Eur. Phys. J. C (2014) 74:3071 Page 31 of 48 3071 0.04 ATLAS 0.035 ∫ 0.04 -1 s=8 TeV, Ldt = 20.3 fb 0.035 Electrons, |η|=0.2 0.03 0.03 0.02 Unconverted photons, |η|=0.2 0.02 0.015 0.015 0.01 0.01 0.005 0.005 0 ∫ s=8 TeV, Ldt = 20.3 fb-1 0.025 σ/E σ/E 0.025 ATLAS 20 40 60 80 0 100 120 140 160 180 200 20 40 60 80 100 120 140 160 180 200 ET [GeV] ET [GeV] Fig. 35 Resolution curve and its uncertainty as a function of E T for electrons (left) and unconverted photons (right) with |η| = 0.2 0.5 0.4 0.3 0.25 0.45 s=8 TeV, Ldt = 20.3 fb Total Cst. term (Z→ ee) Sampling term Material Pileup 0.35 Δσ / σ ∫ ATLAS 0.3 0.25 0.15 0.1 0.1 0.05 0.05 20 40 60 80 Unconv. photons, |η|=0.2 0.2 0.15 0 -1 s=8 TeV, Ldt = 20.3 fb Total Cst. term (Z→ ee) Sampling term Material Pileup 0.35 0.2 ∫ ATLAS 0.4 Electrons, |η|=0.2 Δσ / σ 0.45 0.5 -1 0 100 120 140 160 180 200 20 40 60 ET [GeV] 80 100 120 140 160 180 200 ET [GeV] Fig. 36 Contributions of the different uncertainties to the relative resolution uncertainty as a function of E T for electrons (left) and unconverted photons (right) with |η| = 0.2 pseudo-data, and the impact of the additional passive material on the reconstructed Z → ee invariant mass distribution is calculated as in Sect. 9.1, yielding a material-induced constant term correction. This correction is applied to simulated particles in the nominal geometry; subtracting the result in quadrature from the actual particle resolution obtained in the distorted simulation yields the material contribution to the resolution uncertainty. The impact is 2 2 2 mat (E, η) = σdist (E, η) − σnom (E, η) − cdist (η), (17) where cdist is the material-induced resolution correction obtained as described above. The resolutions σdist (E, η) and σnom (E, η) are parameterised for electrons and photons separately; hence mat (E, η) depends on particle type, energy and η. A given uncertainty source i (i = c, int, mat, noise) contributes to a change i in the squared resolution. Its contribution to the total resolution uncertainty is δσi =  σ02 + i − σ0 , (18) where σ0 (E, η) is the nominal energy resolution. The δσi summed in quadrature give the total resolution uncertainty. The resolution curve is shown for electrons and unconverted photons in Fig. 35, as a function of energy for |η| = 0.2. The different contributions to the resolution uncertainty are shown in Fig. 36. The relative uncertainty is minimal for electrons at E T = 40 GeV, where the measurement of c translates into an uncertainty of 5 %. At higher transverse energy, the sampling term and detector material contributions are significant; at low energy, the pile-up contribution dominates. For unconverted photons, the uncertainty is about 10 % for E T = 40 GeV. The asymptotic resolution uncertainty is given by the accuracy of the c constants, which are determined at E T ∼ 40 GeV. At high energy, the increased contribution of the third sampling and the turn-on of low-gain amplification (mentioned in Sect. 10) are not expected to generate energy fluctuations that invalidate this model. 123 3071 Page 32 of 48 Eur. Phys. J. C (2014) 74:3071 0.025 ATLAS ∫ L dt = 20.3 fb 0.14 -1 0.12 Cluster Combined Arbitrary units Arbitrary units 0.02 s=8 TeV; 0.015 0.01 0.1 ATLAS s=8 TeV; ∫ L dt = 20.3 fb -1 Cluster Combined 0.08 0.06 0.04 0.005 0.02 0 2 2.2 2.4 2.6 2.8 3 3.2 3.4 3.6 3.8 4 0 50 60 70 80 90 100 110 120 130 mee [GeV] mee [GeV] Fig. 37 The electron pair invariant mass distribution, as reconstructed from data using either the calibrated cluster energies, or the combination of the cluster energy and the track momentum. Left J/ψ → ee selection. Right Z → ee selection, with one electron candidate in 1.37 < |η| < 1.52 15 Energy–momentum combination Combining the track momentum and cluster energy measurements improves the electron energy resolution, in particular for electrons of low energy. For electrons, the momentum provided by the ID provides the best measurement for lowpT particles, whereas the calorimeter energy measurement is superior at high pT . The combination also improves the electron resolution in the transition region of the electromagnetic calorimeter, 1.37 < |η| < 1.52. This method is not applied for |η| > 1.52. The method relies on the ID momentum and calorimeter energy response functions determined from simulation. Electrons are categorised according to transverse momentum (7 < pT < 15 GeV, 15 < pT < 30 GeV, pT > 30 GeV) and pseudorapidity (|η| < 0.8, 0.8 < |η| < 1.37, 1.37 < |η| < 1.52, |η| > 1.52). For each category, the distributions of pTreco / pTtrue and E Treco / pTtrue are parameterised using Crystal Ball functions. The following likelihood is then maximised for a given electron candidate:  ET pT · f Calo , (19) L(x) = f ID x x where f ID and f Calo represent the ID and EM calorimeter response functions, and x represents the combined transverse momentum. The combined transverse momentum is given by the value of x for which L(x) is maximal. The results are illustrated in Fig. 37. In the low E T range, the performance of the combination algorithm is assessed using J/ψ events. The invariant mass resolution is improved by about 20 % and the low-mass tails are significantly reduced. A significant improvement is also obtained for Z decay electrons in the calorimeter barrel–endcap transition region where the tracking information compensates for the locally poor energy measurement. 123 Energy–momentum combination is applied in measurements involving final states with low-E T electrons, such as Higgs boson decays to four leptons [36]. The systematic uncertainty on the combined momentum is given by the cluster energy scale uncertainty summarised in Sect. 10, and by the momentum scale uncertainty. The latter is assessed using J/ψ → ee events reconstructed using ID information only. Comparing the position of the electron pair invariant mass peak in data and simulation yields a systematic uncertainty ranging from about 0.1 % near η = 0 to about 1 % in the barrel–endcap transition region. The cluster energy and track momentum systematic uncertainties are combined in quadrature to obtain the total uncertainty on the combined energy–momentum scale. 16 Summary The calibration procedure for electron and photon energy measurement with the ATLAS detector is presented using LHC Run 1 proton–proton collision data corresponding to a total integrated luminosity of about 25 fb−1 taken at √ √ centre-of-mass energies of s = 7 and s = 8 TeV. The calorimeter energy measurement is optimised on simulation using MVA techniques, improving the energy resolution with respect to the previous calibration approach [3] by about 10 % (20 %) for unconverted (converted) photons; for electrons, the improvement ranges from a few percent in most of the acceptance up to 30 % in the region with the largest amount of material upstream of the active calorimeter, 1.52 < |η| < 1.82. The calorimeter energy response in data is stable at the level of 0.05 % as a function of time and pile-up. After corrections for local mechanical and high-voltage defects, the azimuthal non-uniformity is less than 0.5 % in the barrel, and Eur. Phys. J. C (2014) 74:3071 less than 0.75 % in the endcap, meeting the original design goals. The relative response of the calorimeter layers is analysed, notably correcting a bias of about 3 % in the barrel. After calibration corrections, the shower depth is used to probe the amount of material upstream of the calorimeter with a typical accuracy of 3–10 %X 0 , depending on pseudorapidity; the detector material description is adjusted accordingly. The MVA calibration is optimised with the improved simulation, and the calorimeter absolute energy scale is determined using electron pairs from Z boson decays. This procedure yields definite predictions for the energy dependence of the electron and photon calibration and its uncertainty. The uncertainty for electrons at E T ∼ 40 GeV is on average 0.04 % for |η| < 1.37, 0.2 % for 1.37 < |η| < 1.82 and 0.05 % for |η| > 1.82. At E T ∼ 11 GeV, the electron response uncertainty ranges from 0.4 to 1 % for |η| < 1.37, is about 1.1 % for 1.37 < |η| < 1.82, and again 0.4 % for |η| > 1.82. The photon energy scale uncertainty is typically 0.2–0.3 % for |η| < 1.37 and |η| > 1.82; for 1.52 < |η| < 1.82, the uncertainty is 0.9 and 0.4 % for unconverted and converted photons, respectively. Outside of this range, similar accuracy is achieved for converted and unconverted photons, and the energy dependence is weak. The electron and photon calibration is confirmed using independent resonances provided by J/ψ events and Z boson radiative decays. The present energy scale uncertainty model is expected to be valid up to E T ∼ 500 GeV. Finally, the relative uncertainty on the energy resolution is better than 10 % for E T < 50 GeV, and asymptotically rises to about 40 % at high energy. For analyses involving lowE T electrons, an energy–momentum combination algorithm is defined, which improves the electron energy resolution obtained from the calorimeter cluster by about 20 % for E T < 30 GeV and |η| < 1.52. The present results form the basis of ATLAS precision measurements using electrons and photons in LHC Run-1 data. Page 33 of 48 3071 lenberg Foundation, Sweden; SER, SNSF and Cantons of Bern and Geneva, Switzerland; NSC, Taiwan; TAEK, Turkey; STFC, the Royal Society and Leverhulme Trust, UK; DOE and NSF, USA. The crucial computing support from all WLCG partners is acknowledged gratefully, in particular from CERN and the ATLAS Tier-1 facilities at TRIUMF (Canada), NDGF (Denmark, Norway, Sweden), CC-IN2P3 (France), KIT/GridKA (Germany), INFN-CNAF (Italy), NL-T1 (The Netherlands), PIC (Spain), ASGC (Taiwan), RAL (UK) and BNL (USA) and in the Tier-2 facilities worldwide. Open Access This article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited. Funded by SCOAP3 / License Version CC BY 4.0. Appendix A: Calibration results using 2011 data The calibration procedure described in this paper was applied to 4.7 fb−1 of data collected at 7 TeV, and the same crosscheck measurements are carried out. The event selections are modified to account for the different trigger conditions, yielding a sample of about 1.1M Z → ee events, 100K J/ψ → ee events and 90K Z → γ events. The intercalibration constants and effective smearing corrections are shown in Figs. 38 and 39. The binning in pseudorapidity is identical to that used in the 8 TeV data analysis. The features observed with the 2011 data are similar to those observed in 2012, up to small differences expected from the lower pile-up conditions and changes in the OFC optimisation procedure. The energy scale uniformity obtained using J/ψ → ee events, after application of the full calibration chain, is shown in Fig. 40. As in 2012, the results agree within uncertainties, although a bias of one standard deviation is observed for |η| > 0.6. 0.04 ∫ 0.02 α 0 -0.02 -0.04 -3 δ α (10 ) Acknowledgments We thank CERN for the very successful operation of the LHC, as well as the support staff from our institutions without whom ATLAS could not be operated efficiently. We acknowledge the support of ANPCyT, Argentina; YerPhI, Armenia; ARC, Australia; BMWF and FWF, Austria; ANAS, Azerbaijan; SSTC, Belarus; CNPq and FAPESP, Brazil; NSERC, NRC and CFI, Canada; CERN; CONICYT, Chile; CAS, MOST and NSFC, China; COLCIENCIAS, Colombia; MSMT CR, MPO CR and VSC CR, Czech Republic; DNRF, DNSRC and Lundbeck Foundation, Denmark; EPLANET, ERC and NSRF, European Union; IN2P3-CNRS, CEA-DSM/IRFU, France; GNSF, Georgia; BMBF, DFG, HGF, MPG and AvH Foundation, Germany; GSRT and NSRF, Greece; ISF, MINERVA, GIF, ICORE and Benoziyo Center, Israel; INFN, Italy; MEXT and JSPS, Japan; CNRST, Morocco; FOM and NWO, The Netherlands; BRF and RCN, Norway; MNiSW and NCN, Poland; GRICES and FCT, Portugal; MNE/IFA, Romania; MES of Russia and ROSATOM, Russian Federation; JINR; MSTD, Serbia; MSSR, Slovakia; ARRS and MIZŠ, Slovenia; DST/NRF, South Africa; MINECO, Spain; SRC and Wal- s=7 TeV, Ldt = 4.7 fb-1 ATLAS 4 3.5 3 2.5 2 1.5 1 0.5 0 Z resonance (total uncertainty) Total Stat. -2 -1.5 -1 -0.5 0 0.5 1 1.5 2 η Fig. 38 Top 2011 energy scale corrections α derived from Z → ee events with respect to the 2010 calibration scheme [3], as a function of η. Bottom statistical and total energy scale uncertainties 123 -3 12 10 8 6 4 2 0 Eur. Phys. J. C (2014) 74:3071 0.02 ∫ s=7 TeV, Ldt = 4.7 fb-1 ATLAS Z resonance (total uncertainty) 0.015 0.01 0.005 Δα 0.05 0.045 0.04 0.035 0.03 0.025 0.02 0.015 0.01 0.005 0 δ c (10 ) c 3071 Page 34 of 48 0 -0.005 -0.01 -0.015 Total Stat. ∫ s=7 TeV, Ldt = 4.7 fb-1 ATLAS -0.02 -2 -1.5 -1 -0.5 -2 -1.5 -1 -0.5 0 0.5 1 1.5 2 η Fig. 39 Top 2011 constant term resolution corrections c derived from Z → ee events, as a function of η. Bottom statistical and total uncertainties on c 0.5 1 1.5 2 Fig. 40 Energy scale factors α obtained after Z -based calibration from the J/ψsample as a function of the electron pseudorapidity, using 2011 data. The band represents the calibration systematic uncertainty. The error bars on the data points represent the total uncertainty specific to the J/ψ → ee analysis 0.03 0.02 0.03 J/ψ → ee Electrons, |η|<0.6 Z → ee 0.02 J/ψ → ee Electrons, 0.6<|η|<1 Z → ee Calibration uncertainty Calibration uncertainty 0.01 Δα Δα 0.01 0 -0.01 ∫ ATLAS -0.03 0 -0.01 -0.02 10 20 -0.02 -1 30 40 50 60 70 80 90 ∫ ATLAS s=7 TeV, Ldt = 4.7 fb 100 -0.03 10 20 30 40 Z → ee Calibration uncertainty 0.02 Δα Δα -0.01 90 100 J/ψ → ee Electrons, 1.37<|η|<1.55 Z → ee Calibration uncertainty 0 10 20 -0.02 ∫ s=7 TeV, Ldt = 4.7 fb-1 ATLAS 30 40 50 60 70 80 90 ∫ s=7 TeV, Ldt = 4.7 fb-1 ATLAS 100 -0.03 10 20 30 40 ET [GeV] 50 60 70 80 90 100 ET [GeV] 0.03 0.03 J/ψ → ee Electrons, 1.55<|η|<1.82 Z → ee Calibration uncertainty 0.02 J/ψ → ee Electrons, 1.82<|η|<2.47 Z → ee Calibration uncertainty 0.01 Δα 0.01 Δα 80 -0.01 -0.02 0 -0.01 0 -0.01 -0.02 10 20 -0.02 ∫ s=7 TeV, Ldt = 4.7 fb-1 ATLAS -0.03 70 0.01 0 0.02 60 0.03 J/ψ → ee Electrons, 1<|η|<1.37 0.01 -0.03 50 ET [GeV] 0.03 0.02 -1 s=7 TeV, Ldt = 4.7 fb ET [GeV] 30 40 50 60 70 80 90 ∫ s=7 TeV, Ldt = 4.7 fb-1 ATLAS 100 ET [GeV] Fig. 41 Energy scale factors α obtained after Z -based calibration from the J/ψand the E T -dependent Z → ee analyses, as function of E T , in different pseudorapidity bins and using 2011 data. The band 123 0 η -0.03 10 20 30 40 50 60 70 80 90 100 ET [GeV] represents the calibration systematic uncertainty. The error bars on the data points represent the total uncertainty specific to the cross-check analyses Eur. Phys. J. C (2014) 74:3071 Page 35 of 48 3071 0.025 0.025 Unconverted photons 0.02 0.015 0.01 0.01 0.005 0.005 0 -0.005 Data Calibration uncertainty 0 -0.005 -0.01 -0.01 -0.015 -0.02 Unconverted photons 0.015 Δα Δα 0.02 Data Calibration uncertainty ATLAS 0 0.2 0.4 0.6 0.8 s=7 TeV; 1 ∫ L dt = 4.7 fb -1 1.2 1.4 1.6 1.8 2 2.2 -0.015 -0.02 ATLAS 10 s=7 TeV; 20 30 η 0.06 0.06 Data Calibration uncertainty 40 50 60 Converted photons Data Calibration uncertainty 0.04 0.02 Δα Δα 0.02 0 -0.02 ATLAS -0.04 -1 ET [GeV] Converted photons 0.04 ∫ L dt = 4.7 fb 0 0.2 0.4 0.6 0.8 s=7 TeV; 1 ∫ 0 -0.02 -1 ATLAS L dt = 4.7 fb 1.2 1.4 1.6 1.8 2 2.2 η -0.04 15 20 s=7 TeV; 25 30 35 40 ∫ L dt = 4.7 fb 45 -1 50 55 60 ET [GeV] Fig. 42 Combined photon scale factors α obtained after Z -based calibration for unconverted and converted photons, as a function of |η| (left) and E T (right) and using 2011 data. The band represents the calibration systematic uncertainty. The error bars on the data points represent the total uncertainty specific to the Z → γ analyses The energy-dependent analysis is illustrated in Fig. 41. The Z → ee analysis is performed in four E T bins, namely 27–35–42–50–100 GeV. For 1.37 < |η| < 1.52, an observed energy dependence of the energy scale of about 1 % leads to an increased systematic uncertainty in this region; outside of the transition region, the results are consistent with the Z -based calibration independently of |η| and E T . The radiative photon energy scale derived using Z → γ is shown in Fig. 42. For unconverted photons, the results agree with expectations. The discrepancy between the energy scales obtained for converted photons and the Z -based calibration is within two standard deviations. 3. ATLAS Collaboration, Eur. Phys. J. C 72, 1909 (2012). arXiv:1110.3174 4. ATLAS Collaboration, JINST 3, S08003 (2008) 5. ATLAS Collaboration, ATL-PHYS-PUB-2011-007. https:// cdsweb.cern.ch/record/1345329 6. H. Abreu et al., JINST 5, 09, P09003 (2010). http://stacks.iop.org/ 1748-0221/5/i=09/a=P09003 7. ATLAS Collaboration, Eur. Phys. J. C 70, 3, 723 (2010). http://dx. doi.org/10.1140/epjc/s10052-010-1354-y 8. W.E. Cleland, E.G. Stern, Nucl. Instrum. Methods A 338, 467 (1994) 9. M. Aharrouche et al., Nucl. Instrum. Methods A 614, 400 (2010) 10. W. Lampl et al., ATL-LARG-PUB-2008-002. https://cds.cern.ch/ record/1099735 11. ATLAS Collaboration, JINST. arXiv:1405.3768 [hep-ex] 12. ATLAS Collaboration, Eur. Phys. J. C. arXiv:1404.2240 [hep-ex] 13. ATLAS Collaboration, ATLAS-CONF-2014-032. https://cds.cern. ch/record/1700316 14. ATLAS Collaboration, ATLAS-CONF-2012-123. https://cds.cern. ch/record/1473426 15. M. Cacciari, G. Salam, S. Sapeta, JHEP 04, 065 (2010). http://dx. doi.org/10.1007/JHEP04%282010%29065 16. ATLAS Collaboration, Phys. Rev. D 83, 052005 (2011). arXiv:1012.4389 [hep-ex] References 1. ATLAS Collaboration, Phys. Lett. B 716, 1 (2012). arXiv:1207.7214 [hep-ex] 2. CMS Collaboration, Phys. Lett. B 716, 30 (2012). arXiv:1207.7235 [hep-ex] 123 3071 Page 36 of 48 17. A. Hoecker et al., PoS ACAT, 040 (2007). arXiv:0703039 [physics]. http://tmva.sourceforge.net/ 18. T. Gleisberg et al., JHEP 0902, 007 (2009). arXiv:0811.4622 [hepex] 19. P. Nason, JHEP 0411, 040 (2004). arXiv:0409146 [hep-ph] 20. S. Frixione, P. Nason, C. Oleari, JHEP 0711, 070 (2007). arXiv:0709.2092 [hep-ph] 21. S. Alioli et al., JHEP 1006, 043 (2010). arXiv:1002.2581 [hep-ph] 22. S. Alioli et al., JHEP 0807, 060 (2008). arXiv:0805.4802 [hep-ph] 23. T. Sjostrand, S. Mrenna, P.Z. Skands, Comput. Phys. Commun. 178, 852 (2008). arXiv:0710.3820 [hep-ph] 24. ATLAS Collaboration, Eur. Phys. J. C 70, 823 (2010). arXiv:1005.4568 [physics.ins-det] 25. J. Allison et al., IEEE Trans. Nucl. Sci. 53, 1, 270 (2006) 26. ATLAS Collaboration, Phys. Lett. B 688, 21 (2010). arXiv:1003.3124 [hep-ex] 27. ATLAS Collaboration, New J. Phys. 13, 053033 (2011). arXiv:1012.5104 [hep-ex] Eur. Phys. J. C (2014) 74:3071 28. ATLAS Collaboration, ATLAS-CONF-2010-019. https://cds.cern. ch/record/1277651 29. ATLAS Collaboration, JINST 7, P01013 (2012). arXiv:1110.6191 [hep-ex] 30. ATLAS Collaboration, ATLAS-CONF-2010-007. https://cds.cern. ch/record/1274001 31. ATLAS Collaboration, ATLAS-CONF-2010-037. https://cds.cern. ch/record/1277677 32. S. Frixione, B.R. Webber, JHEP 06, 029 (2002) 33. ATLAS Collaboration. arXiv:0901.0512 [hep-ex] 34. J. Colas et al., Nucl. Instrum. Methods A 582, 429 (2007). arXiv:0709.1094 [physics.ins-det] 35. M. Aharrouche et al., Nucl. Instrum. Methods A 568, 601 (2006). arXiv:0608012 [physics] 36. ATLAS Collaboration, Phys. Rev. D. arXiv:1406.3827 [hep-ex] 37. ATLAS Collaboration, ATLAS-CONF-2012-143. https://cds.cern. ch/record/1491697 The ATLAS Collaboration G. Aad84 , B. Abbott112 , J. Abdallah152 , S. Abdel Khalek116 , O. Abdinov11 , R. Aben106 , B. Abi113 , M. Abolins89 , O. S. AbouZeid159 , H. Abramowicz154 , H. Abreu153 , R. Abreu30 , Y. Abulaiti147a,147b , B. S. Acharya165a,165b , L. Adamczyk38a , D. L. Adams25 , J. Adelman177 , S. Adomeit99 , T. Adye130 , T. Agatonovic-Jovin13a , J. A. Aguilar-Saavedra125a,125f , M. Agustoni17 , S. P. Ahlen22 , F. Ahmadov64,b , G. Aielli134a,134b , H. Akerstedt147a,147b , T. P. A. Åkesson80 , G. Akimoto156 , A. V. Akimov95 , G. L. Alberghi20a,20b , J. Albert170 , S. Albrand55 , M. J. Alconada Verzini70 , M. Aleksa30 , I. N. Aleksandrov64 , C. Alexa26a , G. Alexander154 , G. Alexandre49 , T. Alexopoulos10 , M. Alhroob165a,165b , G. Alimonti90a , L. Alio84 , J. Alison31 , B. M. M. Allbrooke18 , L. J. Allison71 , P. P. Allport73 , J. Almond83 , A. Aloisio103a,103b , A. Alonso36 , F. Alonso70 , C. Alpigiani75 , A. Altheimer35 , B. Alvarez Gonzalez89 , M. G. Alviggi103a,103b , K. Amako65 , Y. Amaral Coutinho24a , C. Amelung23 , D. Amidei88 , S. P. Amor Dos Santos125a,125c , A. Amorim125a,125b , S. Amoroso48 , N. Amram154 , G. Amundsen23 , C. Anastopoulos140 , L. S. Ancu49 , N. Andari30 , T. Andeen35 , C. F. Anders58b , G. Anders30 , K. J. Anderson31 , A. Andreazza90a,90b , V. Andrei58a , X. S. Anduaga70 , S. Angelidakis9 , I. Angelozzi106 , P. Anger44 , A. Angerami35 , F. Anghinolfi30 , A. V. Anisenkov108 , N. Anjos125a , A. Annovi47 , A. Antonaki9 , M. Antonelli47 , A. Antonov97 , J. Antos145b , F. Anulli133a , M. Aoki65 , L. Aperio Bella18 , R. Apolle119,c , G. Arabidze89 , I. Aracena144 , Y. Arai65 , J. P. Araque125a , A. T. H. Arce45 , J-F. Arguin94 , S. Argyropoulos42 , M. Arik19a , A. J. Armbruster30 , O. Arnaez30 , V. Arnal81 , H. Arnold48 , M. Arratia28 , O. Arslan21 , A. Artamonov96 , G. Artoni23 , S. Asai156 , N. Asbah42 , A. Ashkenazi154 , B. Åsman147a,147b , L. Asquith6 , K. Assamagan25 , R. Astalos145a , M. Atkinson166 , N. B. Atlay142 , B. Auerbach6 , K. Augsten127 , M. Aurousseau146b , G. Avolio30 , G. Azuelos94d , Y. Azuma156 , M. A. Baak30 , A. Baas58a , C. Bacci135a,135b , H. Bachacou137 , K. Bachas155 , M. Backes30 , M. Backhaus30 , J. Backus Mayes144 , E. Badescu26a , P. Bagiacchi133a,133b , P. Bagnaia133a,133b , Y. Bai33a , T. Bain35 , J. T. Baines130 , O. K. Baker177 , P. Balek128 , F. Balli137 , E. Banas39 , Sw. Banerjee174 , A. A. E. Bannoura176 , V. Bansal170 , H. S. Bansil18 , L. Barak173 , S. P. Baranov95 , E. L. Barberio87 , D. Barberis50a,50b , M. Barbero84 , T. Barillari100 , M. Barisonzi176 , T. Barklow144 , N. Barlow28 , B. M. Barnett130 , R. M. Barnett15 , Z. Barnovska5 , A. Baroncelli135a , G. Barone49 , A. J. Barr119 , F. Barreiro81 , J. Barreiro Guimarães da Costa57 , R. Bartoldus144 , A. E. Barton71 , P. Bartos145a , V. Bartsch150 , A. Bassalat116 , A. Basye166 , R. L. Bates53 , J. R. Batley28 , M. Battaglia138 , M. Battistin30 , F. Bauer137 , H. S. Bawa144,e , M. D. Beattie71 , T. Beau79 , P. H. Beauchemin162 , R. Beccherle123a,123b , P. Bechtle21 , H. P. Beck17 , K. Becker176 , S. Becker99 , M. Beckingham171 , C. Becot116 , A. J. Beddall19c , A. Beddall19c , S. Bedikian177 , V. A. Bednyakov64 , C. P. Bee149 , L. J. Beemster106 , T. A. Beermann176 , M. Begel25 , K. Behr119 , C. Belanger-Champagne86 , P. J. Bell49 , W. H. Bell49 , G. Bella154 , L. Bellagamba20a , A. Bellerive29 , M. Bellomo85 , K. Belotskiy97 , O. Beltramello30 , O. Benary154 , D. Benchekroun136a , K. Bendtz147a,147b , N. Benekos166 , Y. Benhammou154 , E. Benhar Noccioli49 , J. A. Benitez Garcia160b , D. P. Benjamin45 , J. R. Bensinger23 , K. Benslama131 , S. Bentvelsen106 , D. Berge106 , E. Bergeaas Kuutmann16 , N. Berger5 , F. Berghaus170 , J. Beringer15 , C. Bernard22 , P. Bernat77 , C. Bernius78 , F. U. Bernlochner170 , T. Berry76 , P. Berta128 , C. Bertella84 , G. Bertoli147a,147b , F. Bertolucci123a,123b , C. Bertsche112 , D. Bertsche112 , M. Bessner42 , M. I. Besana90a , G. J. Besjes105 , O. Bessidskaia147a,147b , N. Besson137 , C. Betancourt48 , S. Bethke100 , W. Bhimji46 , R. M. Bianchi124 , L. Bianchini23 , M. Bianco30 , O. Biebel99 , S. P. Bieniek77 , K. Bierwagen54 , J. Biesiada15 , M. Biglietti135a , J. Bilbao De Mendizabal49 , H. Bilokon47 , M. Bindi54 , S. Binet116 , A. Bingul19c , C. Bini133a,133b , C. W. Black151 , J. E. Black144 , K. M. Black22 , D. Blackburn139 , R. E. Blair6 , J.-B. Blanchard137 , T. Blazek145a , I. Bloch42 , C. Blocker23 , W. Blum82,* , U. Blumenschein54 , G. 123 Eur. Phys. J. C (2014) 74:3071 Page 37 of 48 3071 J. Bobbink106 , V. S. Bobrovnikov108 , S. S. Bocchetta80 , A. Bocci45 , C. Bock99 , C. R. Boddy119 , M. Boehler48 , J. Boek176 , J. Boek176 , T. T. Boek176 , J. A. Bogaerts30 , A. G. Bogdanchikov108 , A. Bogouch91,* , C. Bohm147a , J. Bohm126 , V. Boisvert76 , T. Bold38a , V. Boldea26a , A. S. Boldyrev98 , M. Bomben79 , M. Bona75 , M. Boonekamp137 , A. Borisov129 , G. Borissov71 , M. Borri83 , S. Borroni42 , J. Bortfeldt99 , V. Bortolotto135a,135b , K. Bos106 , D. Boscherini20a , M. Bosman12 , H. Boterenbrood106 , J. Boudreau124 , J. Bouffard2 , E. V. Bouhova-Thacker71 , D. Boumediene34 , C. Bourdarios116 , N. Bousson113 , S. Boutouil136d , A. Boveia31 , J. Boyd30 , I. R. Boyko64 , J. Bracinik18 , A. Brandt8 , G. Brandt15 , O. Brandt58a , U. Bratzler157 , B. Brau85 , J. E. Brau115 , H. M. Braun176,* , S. F. Brazzale165a,165c , B. Brelier159 , K. Brendlinger121 , A. J. Brennan87 , R. Brenner167 , S. Bressler173 , K. Bristow146c , T. M. Bristow46 , D. Britton53 , F. M. Brochu28 , I. Brock21 , R. Brock89 , C. Bromberg89 , J. Bronner100 , G. Brooijmans35 , T. Brooks76 , W. K. Brooks32b , J. Brosamer15 , E. Brost115 , J. Brown55 , P. A. Bruckman de Renstrom39 , D. Bruncko145b , R. Bruneliere48 , S. Brunet60 , A. Bruni20a , G. Bruni20a , M. Bruschi20a , L. Bryngemark80 , T. Buanes14 , Q. Buat143 , F. Bucci49 , P. Buchholz142 , R. M. Buckingham119 , A. G. Buckley53 , S. I. Buda26a , I. A. Budagov64 , F. Buehrer48 , L. Bugge118 , M. K. Bugge118 , O. Bulekov97 , A. C. Bundock73 , H. Burckhart30 , S. Burdin73 , B. Burghgrave107 , S. Burke130 , I. Burmeister43 , E. Busato34 , D. Büscher48 , V. Büscher82 , P. Bussey53 , C. P. Buszello167 , B. Butler57 , J. M. Butler22 , A. I. Butt3 , C. M. Buttar53 , J. M. Butterworth77 , P. Butti106 , W. Buttinger28 , A. Buzatu53 , M. Byszewski10 , S. Cabrera Urbán168 , D. Caforio20a,20b , O. Cakir4a , P. Calafiura15 , A. Calandri137 , G. Calderini79 , P. Calfayan99 , R. Calkins107 , L. P. Caloba24a , D. Calvet34 , S. Calvet34 , R. Camacho Toro49 , S. Camarda42 , D. Cameron118 , L. M. Caminada15 , R. Caminal Armadans12 , S. Campana30 , M. Campanelli77 , A. Campoverde149 , V. Canale103a,103b , A. Canepa160a , M. Cano Bret75 , J. Cantero81 , R. Cantrill125a125 , T. Cao40 , M. D. M. Capeans Garrido30 , I. Caprini26a , M. Caprini26a , M. Capua37a,37b , R. Caputo82 , R. Cardarelli134a , T. Carli30 , G. Carlino103a , L. Carminati90a,90b , S. Caron105 , E. Carquin32a , G. D. Carrillo-Montoya146c , J. R. Carter28 , J. Carvalho125a,125c , D. Casadei77 , M. P. Casado12 , M. Casolino12 , E. Castaneda-Miranda146b , A. Castelli106 , V. Castillo Gimenez168 , N. F. Castro125a , P. Catastini57 , A. Catinaccio30 , J. R. Catmore118 , A. Cattai30 , G. Cattani134a,134b , S. Caughron89 , V. Cavaliere166 , D. Cavalli90a , M. Cavalli-Sforza12 , V. Cavasinni123a,123c , F. Ceradini135a,135b , B. Cerio45 , K. Cerny128 , A. S. Cerqueira24b , A. Cerri150 , L. Cerrito75 , F. Cerutti15 , M. Cerv30 , A. Cervelli17 , S. A. Cetin19b , A. Chafaq136a , D. Chakraborty107 , I. Chalupkova128 , P. Chang166 , B. Chapleau86 , J. D. Chapman28 , D. Charfeddine116 , D. G. Charlton18 , C. C. Chau159 , C. A. Chavez Barajas150 , S. Cheatham86 , A. Chegwidden89 , S. Chekanov6 , S. V. Chekulaev160a , G. A. Chelkov64f , M. A. Chelstowska88 , C. Chen63 , H. Chen25 , K. Chen149 , L. Chen33d,g , S. Chen33c , X. Chen146c , Y. Chen66 , Y. Chen35 , H. C. Cheng88 , Y. Cheng31 , A. Cheplakov64 , R. Cherkaoui El Moursli136e , V. Chernyatin25,* , E. Cheu7 , L. Chevalier137 , V. Chiarella47 , G. Chiefari103a,103b , J. T. Childers6 , A. Chilingarov71 , G. Chiodini72a , A. S. Chisholm18 , R. T. Chislett77 , A. Chitan26a , M. V. Chizhov64 , S. Chouridou9 , B. K. B. Chow99 , D. Chromek-Burckhart30 , M. L. Chu152 , J. Chudoba126 , J. J. Chwastowski39 , L. Chytka114 , G. Ciapetti133a,133b , A. K. Ciftci4a , R. Ciftci4a , D. Cinca53 , V. Cindro74 , A. Ciocio15 , P. Cirkovic13b , Z. H. Citron173 , M. Citterio90a , M. Ciubancan26a , A. Clark49 , P. J. Clark46 , R. N. Clarke15 , W. Cleland124 , J. C. Clemens84 , C. Clement147a,147b , Y. Coadou84 , M. Cobal165a,165c , A. Coccaro139 , J. Cochran63 , L. Coffey23 , J. G. Cogan144 , J. Coggeshall166 , B. Cole35 , S. Cole107 , A. P. Colijn106 , J. Collot55 , T. Colombo58c , G. Colon85 , G. Compostella100 , P. Conde Muiño125a,125b , E. Coniavitis48 , M. C. Conidi12 , S. H. Connell146b , I. A. Connelly76 , S. M. Consonni90a,90b , V. Consorti48 , S. Constantinescu26a , C. Conta120a,120b , G. Conti57 , F. Conventi103a,h , M. Cooke15 , B. D. Cooper77 , A. M. Cooper-Sarkar119 , N. J. Cooper-Smith76 , K. Copic15 , T. Cornelissen176 , M. Corradi20a , F. Corriveau86,i , A. Corso-Radu164 , A. Cortes-Gonzalez12 , G. Cortiana100 , G. Costa90a , M. J. Costa168 , D. Costanzo140 , D. Côté8 , G. Cottin28 , G. Cowan76 , B. E. Cox83 , K. Cranmer109 , G. Cree29 , S. Crépé-Renaudin55 , F. Crescioli79 , W. A. Cribbs147a,147b , M. Crispin Ortuzar119 , M. Cristinziani21 , V. Croft105 , G. Crosetti37a,37b , C.-M. Cuciuc26a , T. Cuhadar Donszelmann140 , J. Cummings177 , M. Curatolo47 , C. Cuthbert151 , H. Czirr142 , P. Czodrowski3 , Z. Czyczula177 , S. D’Auria53 , M. D’Onofrio73 , M. J. Da Cunha Sargedas De Sousa125a,125b , C. Da Via83 , W. Dabrowski38a , A. Dafinca119 , T. Dai88 , O. Dale14 , F. Dallaire94 , C. Dallapiccola85 , M. Dam36 , A. C. Daniells18 , M. Dano Hoffmann137 , V. Dao48 , G. Darbo50a , S. Darmora8 , J. A. Dassoulas42 , A. Dattagupta60 , W. Davey21 , C. David170 , T. Davidek128 , E. Davies119,c , M. Davies154 , O. Davignon79 , A. R. Davison77 , P. Davison77 , Y. Davygora58a , E. Dawe143 , I. Dawson140 , R. K. Daya-Ishmukhametova85 , K. De8 , R. de Asmundis103a , S. De Castro20a,20b , S. De Cecco79 , N. De Groot105 , P. de Jong106 , H. De la Torre81 , F. De Lorenzi63 , L. De Nooij106 , D. De Pedis133a , A. De Salvo133a , U. De Sanctis165a,165b , A. De Santo150 , J. B. De Vivie De Regie116 , W. J. Dearnaley71 , R. Debbe25 , C. Debenedetti138 , B. Dechenaux55 , D. V. Dedovich64 , I. Deigaard106 , J. Del Peso81 , T. Del Prete123a,123b , F. Deliot137 , C. M. Delitzsch49 , M. Deliyergiyev74 , A. Dell’Acqua30 , L. Dell’Asta22 , M. Dell’Orso123a,123b , M. Della Pietra103a,h , D. della Volpe49 , M. Delmastro5 , P. A. Delsart55 , C. Deluca106 , S. Demers177 , M. Demichev64 , A. Demilly79 , S. P. Denisov129 , D. Derendarz39 , J. E. Derkaoui136d , F. Derue79 , P. Dervan73 , K. Desch21 , C. Deterre42 , P. O. Deviveiros106 , A. Dewhurst130 , S. Dhaliwal106 , A. Di Ciaccio134a,134b , L. Di Ciaccio5 , A. Di Domenico133a,133b , C. Di Donato103a,103b , A. Di Girolamo30 , B. Di Girolamo30 , A. Di Mattia153 , B. Di Micco135a,135b , R. Di Nardo47 , A. Di Simone48 , R. Di Sipio20a,20b , D. Di Valentino29 , F. A. Dias46 , M. A. Diaz32a , E. B. Diehl88 , J. Dietrich42 , T. A. Dietzsch58a , S. Diglio84 , A. Dimitrievska13a , J. Dingfelder21 , C. Dionisi133a,133b , P. Dita26a , S. Dita26a , F. Dittus30 , F. Djama84 , 123 3071 Page 38 of 48 Eur. Phys. J. C (2014) 74:3071 T. Djobava51b , M. A. B. do Vale24c , A. Do Valle Wemans125a,125g , T. K. O. Doan5 , D. Dobos30 , C. Doglioni49 , T. Doherty53 , T. Dohmae156 , J. Dolejsi128 , Z. Dolezal128 , B. A. Dolgoshein97,* , M. Donadelli24d , S. Donati123a,123b , P. Dondero120a,120b , J. Donini34 , J. Dopke130 , A. Doria103a , M. T. Dova70 , A. T. Doyle53 , M. Dris10 , J. Dubbert88 , S. Dube15 , E. Dubreuil34 , E. Duchovni173 , G. Duckeck99 , O. A. Ducu26a , D. Duda176 , A. Dudarev30 , F. Dudziak63 , L. Duflot116 , L. Duguid76 , M. Dührssen30 , M. Dunford58a , H. Duran Yildiz4a , M. Düren52 , A. Durglishvili51b , M. Dwuznik38a , M. Dyndal38a , J. Ebke99 , W. Edson2 , N. C. Edwards46 , W. Ehrenfeld21 , T. Eifert144 , G. Eigen14 , K. Einsweiler15 , T. Ekelof167 , M. El Kacimi136c , M. Ellert167 , S. Elles5 , F. Ellinghaus82 , N. Ellis30 , J. Elmsheuser99 , M. Elsing30 , D. Emeliyanov130 , Y. Enari156 , O. C. Endner82 , M. Endo117 , R. Engelmann149 , J. Erdmann177 , A. Ereditato17 , D. Eriksson147a , G. Ernis176 , J. Ernst2 , M. Ernst25 , J. Ernwein137 , D. Errede166 , S. Errede166 , E. Ertel82 , M. Escalier116 , H. Esch43 , C. Escobar124 , B. Esposito47 , A. I. Etienvre137 , E. Etzion154 , H. Evans60 , A. Ezhilov122 , L. Fabbri20a,20b , G. Facini31 , R. M. Fakhrutdinov129 , S. Falciano133a , R. J. Falla77 , J. Faltova128 , Y. Fang33a , M. Fanti90a,90b , A. Farbin8 , A. Farilla135a , T. Farooque12 , S. Farrell15 , S. M. Farrington171 , P. Farthouat30 , F. Fassi136e , P. Fassnacht30 , D. Fassouliotis9 , A. Favareto50a,50b , L. Fayard116 , P. Federic145a , O. L. Fedin122,j , W. Fedorko169 , M. Fehling-Kaschek48 , S. Feigl30 , L. Feligioni84 , C. Feng33d , E. J. Feng6 , H. Feng88 , A. B. Fenyuk129 , S. Fernandez Perez30 , S. Ferrag53 , J. Ferrando53 , A. Ferrari167 , P. Ferrari106 , R. Ferrari120a , D. E. Ferreira de Lima53 , A. Ferrer168 , D. Ferrere49 , C. Ferretti88 , A. Ferretto Parodi50a,50b , M. Fiascaris31 , F. Fiedler82 , A. Filipčič74 , M. Filipuzzi42 , F. Filthaut105 , M. FinckeKeeler170 , K. D. Finelli151 , M. C. N. Fiolhais125a,125c , L. Fiorini168 , A. Firan40 , A. Fischer2 , J. Fischer176 , W. C. Fisher89 , E. A. Fitzgerald23 , M. Flechl48 , I. Fleck142 , P. Fleischmann88 , S. Fleischmann176 , G. T. Fletcher140 , G. Fletcher75 , T. Flick176 , A. Floderus80 , L. R. Flores Castillo174k , A. C. Florez Bustos160b , M. J. Flowerdew100 , A. Formica137 , A. Forti83 , D. Fortin160a , D. Fournier116 , H. Fox71 , S. Fracchia12 , P. Francavilla79 , M. Franchini20a,20b , S. Franchino30 , D. Francis30 , L. Franconi118 , M. Franklin57 , S. Franz61 , M. Fraternali120a,120b , S. T. French28 , C. Friedrich42 , F. Friedrich44 , D. Froidevaux30 , J. A. Frost28 , C. Fukunaga157 , E. Fullana Torregrosa82 , B. G. Fulsom144 , J. Fuster168 , C. Gabaldon55 , O. Gabizon173 , A. Gabrielli20a,20b , A. Gabrielli133a,133b , S. Gadatsch106 , S. Gadomski49 , G. Gagliardi50a,50b , P. Gagnon60 , C. Galea105 , B. Galhardo125a,125c , E. J. Gallas119 , V. Gallo17 , B. J. Gallop130 , P. Gallus127 , G. Galster36 , K. K. Gan110 , J. Gao33b,g , Y. S. Gao144,e , F. M. Garay Walls46 , F. Garberson177 , C. García168 , J. E. García Navarro168 , M. Garcia-Sciveres15 , R. W. Gardner31 , N. Garelli144 , V. Garonne30 , C. Gatti47 , G. Gaudio120a , B. Gaur142 , L. Gauthier94 , P. Gauzzi133a,133b , I. L. Gavrilenko95 , C. Gay169 , G. Gaycken21 , E. N. Gazis10 , P. Ge33d , Z. Gecse169 , C. N. P. Gee130 , D. A. A. Geerts106 , Ch. Geich-Gimbel21 , K. Gellerstedt147a,147b , C. Gemme50a , A. Gemmell53 , M. H. Genest55 , S. Gentile133a,133b , M. George54 , S. George76 , D. Gerbaudo164 , A. Gershon154 , H. Ghazlane136b , N. Ghodbane34 , B. Giacobbe20a , S. Giagu133a,133b , V. Giangiobbe12 , P. Giannetti123a,123b , F. Gianotti30 , B. Gibbard25 , S. M. Gibson76 , M. Gilchriese15 , T. P. S. Gillam28 , D. Gillberg30 , G. Gilles34 , D. M. Gingrich3,d , N. Giokaris9 , M. P. Giordani165a,165c , R. Giordano103a,103b , F. M. Giorgi20a , F. M. Giorgi16 , P. F. Giraud137 , D. Giugni90a , C. Giuliani48 , M. Giulini58b , B. K. Gjelsten118 , S. Gkaitatzis155 , I. Gkialas155,l , L. K. Gladilin98 , C. Glasman81 , J. Glatzer30 , P. C. F. Glaysher46 , A. Glazov42 , G. L. Glonti64 , M. Goblirsch-Kolb100 , J. R. Goddard75 , J. Godfrey143 , J. Godlewski30 , C. Goeringer82 , S. Goldfarb88 , T. Golling177 , D. Golubkov129 , A. Gomes125a,125b,125d , L. S. Gomez Fajardo42 , R. Gonçalo125a , J. Goncalves Pinto Firmino Da Costa137 , L. Gonella21 , S. González de la Hoz168 , G. Gonzalez Parra12 , S. Gonzalez-Sevilla49 , L. Goossens30 , P. A. Gorbounov96 , H. A. Gordon25 , I. Gorelov104 , B. Gorini30 , E. Gorini72a,72b , A. Gorišek74 , E. Gornicki39 , A. T. Goshaw6 , C. Gössling43 , M. I. Gostkin64 , M. Gouighri136a , D. Goujdami136c , M. P. Goulette49 , A. G. Goussiou139 , C. Goy5 , S. Gozpinar23 , H. M. X. Grabas137 , L. Graber54 , I. Grabowska-Bold38a , P. Grafström20a,20b , K.-J. Grahn42 , J. Gramling49 , E. Gramstad118 , S. Grancagnolo16 , V. Grassi149 , V. Gratchev122 , H. M. Gray30 , E. Graziani135a , O. G. Grebenyuk122 , Z. D. Greenwood78,m , K. Gregersen77 , I. M. Gregor42 , P. Grenier144 , J. Griffiths8 , A. A. Grillo138 , K. Grimm71 , S. Grinstein12,n , Ph. Gris34 , Y. V. Grishkevich98 , J.-F. Grivaz116 , J. P. Grohs44 , A. Grohsjean42 , E. Gross173 , J. Grosse-Knetter54 , G. C. Grossi134a,134b , J. Groth-Jensen173 , Z. J. Grout150 , L. Guan33b , F. Guescini49 , D. Guest177 , O. Gueta154 , C. Guicheney34 , E. Guido50a,50b , T. Guillemin116 , S. Guindon2 , U. Gul53 , C. Gumpert44 , J. Gunther127 , J. Guo35 , S. Gupta119 , P. Gutierrez112 , N. G. Gutierrez Ortiz53 , C. Gutschow77 , N. Guttman154 , C. Guyot137 , C. Gwenlan119 , C. B. Gwilliam73 , A. Haas109 , C. Haber15 , H. K. Hadavand8 , N. Haddad136e , P. Haefner21 , S. Hageböeck21 , Z. Hajduk39 , H. Hakobyan178 , M. Haleem42 , D. Hall119 , G. Halladjian89 , K. Hamacher176 , P. Hamal114 , K. Hamano170 , M. Hamer54 , A. Hamilton146a , S. Hamilton162 , G. N. Hamity146c , P. G. Hamnett42 , L. Han33b , K. Hanagaki117 , K. Hanawa156 , M. Hance15 , P. Hanke58a , R. Hann137 , J. B. Hansen36 , J. D. Hansen36 , P. H. Hansen36 , K. Hara161 , A. S. Hard174 , T. Harenberg176 , F. Hariri116 , S. Harkusha91 , D. Harper88 , R. D. Harrington46 , O. M. Harris139 , P. F. Harrison171 , F. Hartjes106 , M. Hasegawa66 , S. Hasegawa102 , Y. Hasegawa141 , A. Hasib112 , S. Hassani137 , S. Haug17 , M. Hauschild30 , R. Hauser89 , M. Havranek126 , C. M. Hawkes18 , R. J. Hawkings30 , A. D. Hawkins80 , T. Hayashi161 , D. Hayden89 , C. P. Hays119 , H. S. Hayward73 , S. J. Haywood130 , S. J. Head18 , T. Heck82 , V. Hedberg80 , L. Heelan8 , S. Heim121 , T. Heim176 , B. Heinemann15 , L. Heinrich109 , J. Hejbal126 , L. Helary22 , C. Heller99 , M. Heller30 , S. Hellman147a,147b , D. Hellmich21 , C. Helsens30 , J. Henderson119 , Y. Heng174 , R. C. W. Henderson71 , C. Hengler42 , A. Henrichs177 , A. M. Henriques Correia30 , S. Henrot-Versille116 , C. Hensel54 , G. H. Herbert16 , Y. Hernández Jiménez168 , R. 123 Eur. Phys. J. C (2014) 74:3071 Page 39 of 48 3071 Herrberg-Schubert16 , G. Herten48 , R. Hertenberger99 , L. Hervas30 , G. G. Hesketh77 , N. P. Hessey106 , R. Hickling75 , E. HigónRodriguez168 , E. Hill170 , J. C. Hill28 , K. H. Hiller42 , S. Hillert21 , S. J. Hillier18 , I. Hinchliffe15 , E. Hines121 , M. Hirose158 , D. Hirschbuehl176 , J. Hobbs149 , N. Hod106 , M. C. Hodgkinson140 , P. Hodgson140 , A. Hoecker30 , M. R. Hoeferkamp104 , F. Hoenig99 , J. Hoffman40 , D. Hoffmann84 , J. I. Hofmann58a , M. Hohlfeld82 , T. R. Holmes15 , T. M. Hong121 , L. Hooft van Huysduynen109 , Y. Horii102 , J.-Y. Hostachy55 , S. Hou152 , A. Hoummada136a , J. Howard119 , J. Howarth42 , M. Hrabovsky114 , I. Hristova16 , J. Hrivnac116 , T. Hryn’ova5 , C. Hsu146c , P. J. Hsu82 , S.-C. Hsu139 , D. Hu35 , X. Hu25 , Y. Huang42 , Z. Hubacek30 , F. Hubaut84 , F. Huegging21 , T. B. Huffman119 , E. W. Hughes35 , G. Hughes71 , M. Huhtinen30 , T. A. Hülsing82 , M. Hurwitz15 , N. Huseynov64,b , J. Huston89 , J. Huth57 , G. Iacobucci49 , G. Iakovidis10 , I. Ibragimov142 , L. Iconomidou-Fayard116 , E. Ideal177 , P. Iengo103a , O. Igonkina106 , T. Iizawa172 , Y. Ikegami65 , K. Ikematsu142 , M. Ikeno65 , Y. Ilchenko31,o , D. Iliadis155 , N. Ilic159 , Y. Inamaru66 , T. Ince100 , P. Ioannou9 , M. Iodice135a , K. Iordanidou9 , V. Ippolito57 , A. Irles Quiles168 , C. Isaksson167 , M. Ishino67 , M. Ishitsuka158 , R. Ishmukhametov110 , C. Issever119 , S. Istin19a , J. M. Iturbe Ponce83 , R. Iuppa134a,134b , J. Ivarsson80 , W. Iwanski39 , H. Iwasaki65 , J. M. Izen41 , V. Izzo103a , B. Jackson121 , M. Jackson73 , P. Jackson1 , M. R. Jaekel30 , V. Jain2 , K. Jakobs48 , S. Jakobsen30 , T. Jakoubek126 , J. Jakubek127 , D. O. Jamin152 , D. K. Jana78 , E. Jansen77 , H. Jansen30 , J. Janssen21 , M. Janus171 , G. Jarlskog80 , N. Javadov64,b , T. Javůrek48 , L. Jeanty15 , J. Jejelava51a,51p , G.-Y. Jeng151 , D. Jennens87 , P. Jenni48q , J. Jentzsch43 , C. Jeske171 , S. Jézéquel5 , H. Ji174 , J. Jia149 , Y. Jiang33b , M. Jimenez Belenguer42 , S. Jin33a , A. Jinaru26a , O. Jinnouchi158 , M. D. Joergensen36 , K. E. Johansson147a,147b , P. Johansson140 , K. A. Johns7 , K. Jon-And147a,147b , G. Jones171 , R. W. L. Jones71 , T. J. Jones73 , J. Jongmanns58a , P. M. Jorge125a,125b , K. D. Joshi83 , J. Jovicevic148 , X. Ju174 , C. A. Jung43 , R. M. Jungst30 , P. Jussel61 , A. Juste Rozas12,n , M. Kaci168 , A. Kaczmarska39 , M. Kado116 , H. Kagan110 , M. Kagan144 , E. Kajomovitz45 , C. W. Kalderon119 , S. Kama40 , A. Kamenshchikov129 , N. Kanaya156 , M. Kaneda30 , S. Kaneti28 , V. A. Kantserov97 , J. Kanzaki65 , B. Kaplan109 , A. Kapliy31 , D. Kar53 , K. Karakostas10 , N. Karastathis10 , M. Karnevskiy82 , S. N. Karpov64 , Z. M. Karpova64 , K. Karthik109 , V. Kartvelishvili71 , A. N. Karyukhin129 , L. Kashif174 , G. Kasieczka58b , R. D. Kass110 , A. Kastanas14 , Y. Kataoka156 , A. Katre49 , J. Katzy42 , V. Kaushik7 , K. Kawagoe69 , T. Kawamoto156 , G. Kawamura54 , S. Kazama156 , V. F. Kazanin108 , M. Y. Kazarinov64 , R. Keeler170 , R. Kehoe40 , M. Keil54 , J. S. Keller42 , J. J. Kempster76 , H. Keoshkerian5 , O. Kepka126 , B. P. Kerševan74 , S. Kersten176 , K. Kessoku156 , J. Keung159 , F. Khalil-zada11 , H. Khandanyan147a,147b , A. Khanov113 , A. Khodinov97 , A. Khomich58a , T. J. Khoo28 , G. Khoriauli21 , A. Khoroshilov176 , V. Khovanskiy96 , E. Khramov64 , J. Khubua51b , H. Y. Kim8 , H. Kim147a,147b , S. H. Kim161 , N. Kimura172 , O. Kind16 , B. T. King73 , M. King168 , R. S. B. King119 , S. B. King169 , J. Kirk130 , A. E. Kiryunin100 , T. Kishimoto66 , D. Kisielewska38a , F. Kiss48 , T. Kittelmann124 , K. Kiuchi161 , E. Kladiva145b , M. Klein73 , U. Klein73 , K. Kleinknecht82 , P. Klimek147a,147b , A. Klimentov25 , R. Klingenberg43 , J. A. Klinger83 , T. Klioutchnikova30 , P. F. Klok105 , E.-E. Kluge58a , P. Kluit106 , S. Kluth100 , E. Kneringer61 , E. B. F. G. Knoops84 , A. Knue53 , D. Kobayashi158 , T. Kobayashi156 , M. Kobel44 , M. Kocian144 , P. Kodys128 , P. Koevesarki21 , T. Koffas29 , E. Koffeman106 , L. A. Kogan119 , S. Kohlmann176 , Z. Kohout127 , T. Kohriki65 , T. Koi144 , H. Kolanoski16 , I. Koletsou5 , J. Koll89 , A. A. Komar95,* , Y. Komori156 , T. Kondo65 , N. Kondrashova42 , K. Köneke48 , A. C. König105 , S. König82 , T. Kono65,r , R. Konoplich109,s , N. Konstantinidis77 , R. Kopeliansky153 , S. Koperny38a , L. Köpke82 , A. K. Kopp48 , K. Korcyl39 , K. Kordas155 , A. Korn77 , A. A. Korol108,t , I. Korolkov12 , E. V. Korolkova140 , V. A. Korotkov129 , O. Kortner100 , S. Kortner100 , V. V. Kostyukhin21 , V. M. Kotov64 , A. Kotwal45 , C. Kourkoumelis9 , V. Kouskoura155 , A. Koutsman160a , R. Kowalewski170 , T. Z. Kowalski38a , W. Kozanecki137 , A. S. Kozhin129 , V. Kral127 , V. A. Kramarenko98 , G. Kramberger74 , D. Krasnopevtsev97 , M. W. Krasny79 , A. Krasznahorkay30 , J. K. Kraus21 , A. Kravchenko25 , S. Kreiss109 , M. Kretz58c , J. Kretzschmar73 , K. Kreutzfeldt52 , P. Krieger159 , K. Kroeninger54 , H. Kroha100 , J. Kroll121 , J. Kroseberg21 , J. Krstic13a , U. Kruchonak64 , H. Krüger21 , T. Kruker17 , N. Krumnack63 , Z. V. Krumshteyn64 , A. Kruse174 , M. C. Kruse45 , M. Kruskal22 , T. Kubota87 , S. Kuday4a , S. Kuehn48 , A. Kugel58c , A. Kuhl138 , T. Kuhl42 , V. Kukhtin64 , Y. Kulchitsky91 , S. Kuleshov32b , M. Kuna133a,133b , J. Kunkle121 , A. Kupco126 , H. Kurashige66 , Y. A. Kurochkin91 , R. Kurumida66 , V. Kus126 , E. S. Kuwertz148 , M. Kuze158 , J. Kvita114 , A. La Rosa49 , L. La Rotonda37a,37b , C. Lacasta168 , F. Lacava133a,133b , J. Lacey29 , H. Lacker16 , D. Lacour79 , V. R. Lacuesta168 , E. Ladygin64 , R. Lafaye5 , B. Laforge79 , T. Lagouri177 , S. Lai48 , H. Laier58a , L. Lambourne77 , S. Lammers60 , C. L. Lampen7 , W. Lampl7 , E. Lançon137 , U. Landgraf48 , M. P. J. Landon75 , V. S. Lang58a , A. J. Lankford164 , F. Lanni25 , K. Lantzsch30 , S. Laplace79 , C. Lapoire21 , J. F. Laporte137 , T. Lari90a , M. Lassnig30 , P. Laurelli47 , W. Lavrijsen15 , A. T. Law138 , P. Laycock73 , O. Le Dortz79 , E. Le Guirriec84 , E. Le Menedeu12 , T. LeCompte6 , F. LedroitGuillon55 , C. A. Lee152 , H. Lee106 , J. S. H. Lee117 , S. C. Lee152 , L. Lee1 , G. Lefebvre79 , M. Lefebvre170 , F. Legger99 , C. Leggett15 , A. Lehan73 , M. Lehmacher21 , G. Lehmann Miotto30 , X. Lei7 , W. A. Leight29 , A. Leisos155 , A. G. Leister177 , M. A. L. Leite24d , R. Leitner128 , D. Lellouch173 , B. Lemmer54 , K. J. C. Leney77 , T. Lenz21 , G. Lenzen176 , B. Lenzi30 , R. Leone7 , S. Leone123a,123b , K. Leonhardt44 , C. Leonidopoulos46 , S. Leontsinis10 , C. Leroy94 , C. G. Lester28 , C. M. Lester121 , M. Levchenko122 , J. Levêque5 , D. Levin88 , L. J. Levinson173 , M. Levy18 , A. Lewis119 , G. H. Lewis109 , A. M. Leyko21 , M. Leyton41 , B. Li33b,u , B. Li84 , H. Li149 , H. L. Li31 , L. Li45 , L. Li33e , S. Li45 , Y. Li33c,v , Z. Liang138 , H. Liao34 , B. Liberti134a , P. Lichard30 , K. Lie166 , J. Liebal21 , W. Liebig14 , C. Limbach21 , A. Limosani87 , S. C. Lin152,w , T. H. Lin82 , F. Linde106 , B. 123 3071 Page 40 of 48 Eur. Phys. J. C (2014) 74:3071 E. Lindquist149 , J. T. Linnemann89 , E. Lipeles121 , A. Lipniacka14 , M. Lisovyi42 , T. M. Liss166 , D. Lissauer25 , A. Lister169 , A. M. Litke138 , B. Liu152 , D. Liu152 , J. B. Liu33b , K. Liu33b,x , L. Liu88 , M. Liu45 , M. Liu33b , Y. Liu33b , M. Livan120a,120b , S. S. A. Livermore119 , A. Lleres55 , J. Llorente Merino81 , S. L. Lloyd75 , F. Lo Sterzo152 , E. Lobodzinska42 , P. Loch7 , W. S. Lockman138 , T. Loddenkoetter21 , F. K. Loebinger83 , A. E. Loevschall-Jensen36 , A. Loginov177 , T. Lohse16 , K. Lohwasser42 , M. Lokajicek126 , V. P. Lombardo5 , B. A. Long22 , J. D. Long88 , R. E. Long71 , L. Lopes125a , D. Lopez Mateos57 , B. Lopez Paredes140 , I. Lopez Paz12 , J. Lorenz99 , N. Lorenzo Martinez60 , M. Losada163 , P. Loscutoff15 , X. Lou41 , A. Lounis116 , J. Love6 , P. A. Love71 , A. J. Lowe144,e , F. Lu33a , N. Lu88 , H. J. Lubatti139 , C. Luci133a,133b , A. Lucotte55 , F. Luehring60 , W. Lukas61 , L. Luminari133a , O. Lundberg147a,147b , B. Lund-Jensen148 , M. Lungwitz82 , D. Lynn25 , R. Lysak126 , E. Lytken80 , H. Ma25 , L. L. Ma33d , G. Maccarrone47 , A. Macchiolo100 , J. Machado Miguens125a,125b , D. Macina30 , D. Madaffari84 , R. Madar48 , H. J. Maddocks71 , W. F. Mader44 , A. Madsen167 , M. Maeno8 , T. Maeno25 , E. Magradze54 , K. Mahboubi48 , J. Mahlstedt106 , S. Mahmoud73 , C. Maiani137 , C. Maidantchik24a , A. A. Maier100 , A. Maio125a,125b,125d , S. Majewski115 , Y. Makida65 , N. Makovec116 , P. Mal137,y , B. Malaescu79 , Pa. Malecki39 , V. P. Maleev122 , F. Malek55 , U. Mallik62 , D. Malon6 , C. Malone144 , S. Maltezos10 , V. M. Malyshev108 , S. Malyukov30 , J. Mamuzic13b , B. Mandelli30 , L. Mandelli90a , I. Mandić74 , R. Mandrysch62 , J. Maneira125a,125b , A. Manfredini100 , L. Manhaes de Andrade Filho24b , J. A. Manjarres Ramos160b , A. Mann99 , P. M. Manning138 , A. Manousakis-Katsikakis9 , B. Mansoulie137 , R. Mantifel86 , L. Mapelli30 , L. March168 , J. F. Marchand29 , G. Marchiori79 , M. Marcisovsky126 , C. P. Marino170 , M. Marjanovic13a , C. N. Marques125a , F. Marroquim24a , S. P. Marsden83 , Z. Marshall15 , L. F. Marti17 , S. Marti-Garcia168 , B. Martin30 , B. Martin89 , T. A. Martin171 , V. J. Martin46 , B. Martin dit Latour14 , H. Martinez137 , M. Martinez12,n , S. Martin-Haugh130 , A. C. Martyniuk77 , M. Marx139 , F. Marzano133a , A. Marzin30 , L. Masetti82 , T. Mashimo156 , R. Mashinistov95 , J. Masik83 , A. L. Maslennikov108 , I. Massa20a,20b , L. Massa20a,20b , N. Massol5 , P. Mastrandrea149 , A. Mastroberardino37a,37b , T. Masubuchi156 , P. Mättig176 , J. Mattmann82 , J. Maurer26a , S. J. Maxfield73 , D. A. Maximov108,t , R. Mazini152 , L. Mazzaferro134a,134b , G. Mc Goldrick159 , S. P. Mc Kee88 , A. McCarn88 , R. L. McCarthy149 , T. G. McCarthy29 , N. A. McCubbin130 , K. W. McFarlane56,* , J. A. Mcfayden77 , G. Mchedlidze54 , S. J. McMahon130 , R. A. McPherson170,i , A. Meade85 , J. Mechnich106 , M. Medinnis42 , S. Meehan31 , S. Mehlhase99 , A. Mehta73 , K. Meier58a , C. Meineck99 , B. Meirose80 , C. Melachrinos31 , B. R. Mellado Garcia146c , F. Meloni17 , A. Mengarelli20a,20b , S. Menke100 , E. Meoni162 , K. M. Mercurio57 , S. Mergelmeyer21 , N. Meric137 , P. Mermod49 , L. Merola103a,103b , C. Meroni90a , F. S. Merritt31 , H. Merritt110 , A. Messina30,z , J. Metcalfe25 , A. S. Mete164 , C. Meyer82 , C. Meyer121 , J.-P. Meyer137 , J. Meyer30 , R. P. Middleton130 , S. Migas73 , L. Mijović21 , G. Mikenberg173 , M. Mikestikova126 , M. Mikuž74 , A. Milic30 , D. W. Miller31 , C. Mills46 , A. Milov173 , D. A. Milstead147a,147b , D. Milstein173 , A. A. Minaenko129 , I. A. Minashvili64 , A. I. Mincer109 , B. Mindur38a , M. Mineev64 , Y. Ming174 , L. M. Mir12 , G. Mirabelli133a , T. Mitani172 , J. Mitrevski99 , V. A. Mitsou168 , S. Mitsui65 , A. Miucci49 , P. S. Miyagawa140 , J. U. Mjörnmark80 , T. Moa147a,147b , K. Mochizuki84 , S. Mohapatra35 , W. Mohr48 , S. Molander147a,147b , R. Moles-Valls168 , K. Mönig42 , C. Monini55 , J. Monk36 , E. Monnier84 , J. Montejo Berlingen12 , F. Monticelli70 , S. Monzani133a,133b , R. W. Moore3 , N. Morange62 , D. Moreno82 , M. Moreno Llácer54 , P. Morettini50a , M. Morgenstern44 , M. Morii57 , S. Moritz82 , A. K. Morley148 , G. Mornacchi30 , J. D. Morris75 , L. Morvaj102 , H. G. Moser100 , M. Mosidze51b , J. Moss110 , K. Motohashi158 , R. Mount144 , E. Mountricha25 , S. V. Mouraviev95,* , E. J. W. Moyse85 , S. Muanza84 , R. D. Mudd18 , F. Mueller58a , J. Mueller124 , K. Mueller21 , T. Mueller28 , T. Mueller82 , D. Muenstermann49 , Y. Munwes154 , J. A. Murillo Quijada18 , W. J. Murray171,130 , H. Musheghyan54 , E. Musto153 , A. G. Myagkov129,aa , M. Myska127 , O. Nackenhorst54 , J. Nadal54 , K. Nagai61 , R. Nagai158 , Y. Nagai84 , K. Nagano65 , A. Nagarkar110 , Y. Nagasaka59 , M. Nagel100 , A. M. Nairz30 , Y. Nakahama30 , K. Nakamura65 , T. Nakamura156 , I. Nakano111 , H. Namasivayam41 , G. Nanava21 , R. Narayan58b , T. Nattermann21 , T. Naumann42 , G. Navarro163 , R. Nayyar7 , H. A. Neal88 , P. Yu. Nechaeva95 , T. J. Neep83 , P. D. Nef144 , A. Negri120a,120b , G. Negri30 , M. Negrini20a , S. Nektarijevic49 , A. Nelson164 , T. K. Nelson144 , S. Nemecek126 , P. Nemethy109 , A. A. Nepomuceno24a , M. Nessi30,ab , M. S. Neubauer166 , M. Neumann176 , R. M. Neves109 , P. Nevski25 , P. R. Newman18 , D. H. Nguyen6 , R. B. Nickerson119 , R. Nicolaidou137 , B. Nicquevert30 , J. Nielsen138 , N. Nikiforou35 , A. Nikiforov16 , V. Nikolaenko129,aa , I. Nikolic-Audit79 , K. Nikolics49 , K. Nikolopoulos18 , P. Nilsson8 , Y. Ninomiya156 , A. Nisati133a , R. Nisius100 , T. Nobe158 , L. Nodulman6 , M. Nomachi117 , I. Nomidis29 , S. Norberg112 , M. Nordberg30 , O. Novgorodova44 , S. Nowak100 , M. Nozaki65 , L. Nozka114 , K. Ntekas10 , G. Nunes Hanninger87 , T. Nunnemann99 , E. Nurse77 , F. Nuti87 , B. J. O’Brien46 , F. O’grady7 , D. C. O’Neil143 , V. O’Shea53 , F. G. Oakham29,d , H. Oberlack100 , T. Obermann21 , J. Ocariz79 , A. Ochi66 , M. I. Ochoa77 , S. Oda69 , S. Odaka65 , H. Ogren60 , A. Oh83 , S. H. Oh45 , C. C. Ohm15 , H. Ohman167 , W. Okamura117 , H. Okawa25 , Y. Okumura31 , T. Okuyama156 , A. Olariu26a , A. G. Olchevski64 , S. A. Olivares Pino46 , D. Oliveira Damazio25 , E. Oliver Garcia168 , A. Olszewski39 , J. Olszowska39 , A. Onofre125a,125e , P. U. E. Onyisi31,o , C. J. Oram160a , M. J. Oreglia31 , Y. Oren154 , D. Orestano135a,135b , N. Orlando72a,72b , C. Oropeza Barrera53 , R. S. Orr159 , B. Osculati50a,50b , R. Ospanov121 , G. Otero y Garzon27 , H. Otono69 , M. Ouchrif136d , E. A. Ouellette170 , F. Ould-Saada118 , A. Ouraou137 , K. P. Oussoren106 , Q. Ouyang33a , A. Ovcharova15 , M. Owen83 , V. E. Ozcan19a , N. Ozturk8 , K. Pachal119 , A. Pacheco Pages12 , C. Padilla Aranda12 , M. Pagáčová48 , S. Pagan Griso15 , E. Paganis140 , C. Pahl100 , F. Paige25 , P. Pais85 , 123 Eur. Phys. J. C (2014) 74:3071 Page 41 of 48 3071 K. Pajchel118 , G. Palacino160b , S. Palestini30 , M. Palka38b , D. Pallin34 , A. Palma125a,125b , J. D. Palmer18 , Y. B. Pan174 , E. Panagiotopoulou10 , J. G. Panduro Vazquez76 , P. Pani106 , N. Panikashvili88 , S. Panitkin25 , D. Pantea26a , L. Paolozzi134a,134b , Th. D. Papadopoulou10 , K. Papageorgiou155,l , A. Paramonov6 , D. Paredes Hernandez34 , M. A. Parker28 , F. Parodi50a,50b , J. A. Parsons35 , U. Parzefall48 , E. Pasqualucci133a , S. Passaggio50a , A. Passeri135a , F. Pastore135a,135b,* , Fr. Pastore76 , G. Pásztor29 , S. Pataraia176 , N. D. Patel151 , J. R. Pater83 , S. Patricelli103a,103b , T. Pauly30 , J. Pearce170 , L. E. Pedersen36 , M. Pedersen118 , S. Pedraza Lopez168 , R. Pedro125a,125b , S. V. Peleganchuk108 , D. Pelikan167 , H. Peng33b , B. Penning31 , J. Penwell60 , D. V. Perepelitsa25 , E. Perez Codina160a , M. T. Pérez García-Estañ168 , V. Perez Reale35 , L. Perini90a,90b , H. Pernegger30 , R. Perrino72a , R. Peschke42 , V. D. Peshekhonov64 , K. Peters30 , R. F. Y. Peters83 , B. A. Petersen30 , T. C. Petersen36 , E. Petit42 , A. Petridis147a,147b , C. Petridou155 , E. Petrolo133a , F. Petrucci135a,135b , N. E. Pettersson158 , R. Pezoa32b , P. W. Phillips130 , G. Piacquadio144 , E. Pianori171 , A. Picazio49 , E. Piccaro75 , M. Piccinini20a,20b , R. Piegaia27 , D. T. Pignotti110 , J. E. Pilcher31 , A. D. Pilkington77 , J. Pina125a,125b,125d , M. Pinamonti165a,165c,ac , A. Pinder119 , J. L. Pinfold3 , A. Pingel36 , B. Pinto125a , S. Pires79 , M. Pitt173 , C. Pizio90a,90b , L. Plazak 145a , M.-A. Pleier25 , V. Pleskot128 , E. Plotnikova64 , P. Plucinski147a,147b , S. Poddar58a , F. Podlyski34 , R. Poettgen82 , L. Poggioli116 , D. Pohl21 , M. Pohl49 , G. Polesello120a , A. Policicchio37a,37b , R. Polifka159 , A. Polini20a , C. S. Pollard45 , V. Polychronakos25 , K. Pommès30 , L. Pontecorvo133a , B. G. Pope89 , G. A. Popeneciu26b , D. S. Popovic13a , A. Poppleton30 , X. Portell Bueso12 , S. Pospisil127 , K. Potamianos15 , I. N. Potrap64 , C. J. Potter150 , C. T. Potter115 , G. Poulard30 , J. Poveda60 , V. Pozdnyakov64 , P. Pralavorio84 , A. Pranko15 , S. Prasad30 , R. Pravahan8 , S. Prell63 , D. Price83 , J. Price73 , L. E. Price6 , D. Prieur124 , M. Primavera72a , M. Proissl46 , K. Prokofiev47 , F. Prokoshin32b , E. Protopapadaki137 , S. Protopopescu25 , J. Proudfoot6 , M. Przybycien38a , H. Przysiezniak5 , E. Ptacek115 , D. Puddu135a,135b , E. Pueschel85 , D. Puldon149 , M. Purohit25,ad , P. Puzo116 , J. Qian88 , G. Qin53 , Y. Qin83 , A. Quadt54 , D. R. Quarrie15 , W. B. Quayle165a,165b , M. Queitsch-Maitland83 , D. Quilty53 , A. Qureshi160b , V. Radeka25 , V. Radescu42 , S. K. Radhakrishnan149 , P. Radloff115 , P. Rados87 , F. Ragusa90a,90b , G. Rahal179 , S. Rajagopalan25 , M. Rammensee30 , A. S. Randle-Conde40 , C. Rangel-Smith167 , K. Rao164 , F. Rauscher99 , T. C. Rave48 , T. Ravenscroft53 , M. Raymond30 , A. L. Read118 , N. P. Readioff73 , D. M. Rebuzzi120a,120b , A. Redelbach175 , G. Redlinger25 , R. Reece138 , K. Reeves41 , L. Rehnisch16 , H. Reisin27 , M. Relich164 , C. Rembser30 , H. Ren33a , Z. L. Ren152 , A. Renaud116 , M. Rescigno133a , S. Resconi90a , O. L. Rezanova108,t , P. Reznicek128 , R. Rezvani94 , R. Richter100 , M. Ridel79 , P. Rieck16 , J. Rieger54 , M. Rijssenbeek149 , A. Rimoldi120a,120b , L. Rinaldi20a , E. Ritsch61 , I. Riu12 , F. Rizatdinova113 , E. Rizvi75 , S. H. Robertson86,i , A. Robichaud-Veronneau86 , D. Robinson28 , J. E. M. Robinson83 , A. Robson53 , C. Roda123a,123b , L. Rodrigues30 , S. Roe30 , O. Røhne118 , S. Rolli162 , A. Romaniouk97 , M. Romano20a,20b , E. Romero Adam168 , N. Rompotis139 , M. Ronzani48 , L. Roos79 , E. Ros168 , S. Rosati133a , K. Rosbach49 , M. Rose76 , P. Rose138 , P. L. Rosendahl14 , O. Rosenthal142 , V. Rossetti147a,147b , E. Rossi103a,103b , L. P. Rossi50a , R. Rosten139 , M. Rotaru26a , I. Roth173 , J. Rothberg139 , D. Rousseau116 , C. R. Royon137 , A. Rozanov84 , Y. Rozen153 , X. Ruan146c , F. Rubbo12 , I. Rubinskiy42 , V. I. Rud98 , C. Rudolph44 , M. S. Rudolph159 , F. Rühr48 , A. Ruiz-Martinez30 , Z. Rurikova48 , N. A. Rusakovich64 , A. Ruschke99 , J. P. Rutherfoord7 , N. Ruthmann48 , Y. F. Ryabov122 , M. Rybar128 , G. Rybkin116 , N. C. Ryder119 , A. F. Saavedra151 , S. Sacerdoti27 , A. Saddique3 , I. Sadeh154 , H. F.-W. Sadrozinski138 , R. Sadykov64 , F. Safai Tehrani133a , H. Sakamoto156 , Y. Sakurai172 , G. Salamanna135a,135b , A. Salamon134a , M. Saleem112 , D. Salek106 , P. H. Sales De Bruin139 , D. Salihagic100 , A. Salnikov144 , J. Salt168 , D. Salvatore37a,37b , F. Salvatore150 , A. Salvucci105 , A. Salzburger30 , D. Sampsonidis155 , A. Sanchez103a,103b , J. Sánchez168 , V. Sanchez Martinez168 , H. Sandaker14 , R. L. Sandbach75 , H. G. Sander82 , M. P. Sanders99 , M. Sandhoff176 , T. Sandoval28 , C. Sandoval163 , R. Sandstroem100 , D. P. C. Sankey130 , A. Sansoni47 , C. Santoni34 , R. Santonico134a,134b , H. Santos125a , I. Santoyo Castillo150 , K. Sapp124 , A. Sapronov64 , J. G. Saraiva125a,125d , B. Sarrazin21 , G. Sartisohn176 , O. Sasaki65 , Y. Sasaki156 , G. Sauvage5,* , E. Sauvan5 , P. Savard156,d , D. O. Savu30 , C. Sawyer119 , L. Sawyer78,m , D. H. Saxon53 , J. Saxon121 , C. Sbarra20a , A. Sbrizzi3 , T. Scanlon77 , D. A. Scannicchio164 , M. Scarcella151 , V. Scarfone37a,37b , J. Schaarschmidt173 , P. Schacht100 , D. Schaefer30 , R. Schaefer42 , S. Schaepe21 , S. Schaetzel58b , U. Schäfer82 , A. C. Schaffer116 , D. Schaile99 , R. D. Schamberger149 , V. Scharf58a , V. A. Schegelsky122 , D. Scheirich128 , M. Schernau164 , M. I. Scherzer35 , C. Schiavi50a,50b , J. Schieck99 , C. Schillo48 , M. Schioppa37a,37b , S. Schlenker30 , E. Schmidt48 , K. Schmieden30 , C. Schmitt82 , S. Schmitt58b , B. Schneider17 , Y. J. Schnellbach73 , U. Schnoor44 , L. Schoeffel137 , A. Schoening58b , B. D. Schoenrock89 , A. L. S. Schorlemmer54 , M. Schott82 , D. Schouten160a , J. Schovancova25 , S. Schramm159 , M. Schreyer175 , C. Schroeder82 , N. Schuh82 , M. J. Schultens21 , H.-C. Schultz-Coulon58a , H. Schulz16 , M. Schumacher48 , B. A. Schumm138 , Ph. Schune137 , C. Schwanenberger83 , A. Schwartzman144 , Ph. Schwegler100 , Ph. Schwemling137 , R. Schwienhorst89 , J. Schwindling137 , T. Schwindt21 , M. Schwoerer5 , F. G. Sciacca17 , E. Scifo116 , G. Sciolla23 , W. G. Scott130 , F. Scuri123a,123b , F. Scutti21 , J. Searcy88 , G. Sedov42 , E. Sedykh122 , S. C. Seidel104 , A. Seiden138 , F. Seifert127 , J. M. Seixas24a , G. Sekhniaidze103a , S. J. Sekula40 , K. E. Selbach46 , D. M. Seliverstov122,* , G. Sellers73 , N. Semprini-Cesari20a,20b , C. Serfon30 , L. Serin116 , L. Serkin54 , T. Serre84 , R. Seuster160a , H. Severini112 , T. Sfiligoj74 , F. Sforza100 , A. Sfyrla30 , E. Shabalina54 , M. Shamim115 , L. Y. Shan33a , R. Shang166 , J. T. Shank22 , M. Shapiro15 , P. B. Shatalov96 , K. Shaw165a,165b , C. Y. Shehu150 , P. Sherwood77 , L.Shi152,ae , S. Shimizu66 , C. O. Shimmin164 , M. Shimojima101 , M. Shiyakova64 , A. Shmeleva95 , M. J. Shochet31 , D. Short119 , S. Shrestha63 , 123 3071 Page 42 of 48 Eur. Phys. J. C (2014) 74:3071 E. Shulga97 , M. A. Shupe7 , S. Shushkevich42 , P. Sicho126 , O. Sidiropoulou155 , D. Sidorov113 , A. Sidoti133a , F. Siegert44 , Dj. Sijacki13a , J. Silva125a,125d , Y. Silver154 , D. Silverstein144 , S. B. Silverstein147a , V. Simak127 , O. Simard5 , Lj. Simic13a , S. Simion116 , E. Simioni82 , B. Simmons77 , R. Simoniello90a,90b , M. Simonyan36 , P. Sinervo159 , N. B. Sinev115 , V. Sipica142 , G. Siragusa175 , A. Sircar78 , A. N. Sisakyan64,* , S. Yu. Sivoklokov98 , J. Sjölin147a,147b , T. B. Sjursen14 , H. P. Skottowe57 , K. Yu. Skovpen108 , P. Skubic112 , M. Slater18 , T. Slavicek127 , K. Sliwa162 , V. Smakhtin173 , B. H. Smart46 , L. Smestad14 , S. Yu. Smirnov97 , Y. Smirnov97 , L. N. Smirnova98,af , O. Smirnova80 , K. M. Smith53 , M. Smizanska71 , K. Smolek127 , A. A. Snesarev95 , G. Snidero75 , S. Snyder25 , R. Sobie170,i , F. Socher44 , A. Soffer154 , D. A. Soh152,ae , C. A. Solans30 , M. Solar127 , J. Solc127 , E. Yu. Soldatov97 , U. Soldevila168 , A. A. Solodkov129 , A. Soloshenko64 , O. V. Solovyanov129 , V. Solovyev122 , P. Sommer48 , H. Y. Song33b , N. Soni1 , A. Sood15 , A. Sopczak127 , B. Sopko127 , V. Sopko127 , V. Sorin12 , M. Sosebee8 , R. Soualah165a,165c , P. Soueid94 , A. M. Soukharev108 , D. South42 , S. Spagnolo72a,72b , F. Spanò76 , W. R. Spearman57 , F. Spettel100 , R. Spighi20a , G. Spigo30 , L. A. Spiller87 , M. Spousta128 , T. Spreitzer159 , B. Spurlock8 , R. D. St. Denis53,* , S. Staerz44 , J. Stahlman121 , R. Stamen58a , S. Stamm16 , E. Stanecka39 , R. W. Stanek6 , C. Stanescu135a , M. StanescuBellu42 , M. M. Stanitzki42 , S. Stapnes118 , E. A. Starchenko129 , J. Stark55 , P. Staroba126 , P. Starovoitov42 , R. Staszewski39 , P. Stavina145a,* , P. Steinberg25 , B. Stelzer143 , H. J. Stelzer30 , O. Stelzer-Chilton160a , H. Stenzel52 , S. Stern100 , G. A. Stewart53 , J. A. Stillings21 , M. C. Stockton86 , M. Stoebe86 , G. Stoicea26a , P. Stolte54 , S. Stonjek100 , A. R. Stradling8 , A. Straessner44 , M. E. Stramaglia17 , J. Strandberg148 , S. Strandberg147a,147b , A. Strandlie118 , E. Strauss144 , M. Strauss112 , P. Strizenec145b , R. Ströhmer175 , D. M. Strom115 , R. Stroynowski40 , A. Struebig105 , S. A. Stucci17 , B. Stugu14 , N. A. Styles42 , D. Su144 , J. Su124 , R. Subramaniam78 , A. Succurro12 , Y. Sugaya117 , C. Suhr107 , M. Suk127 , V. V. Sulin95 , S. Sultansoy4c , T. Sumida67 , S. Sun57 , X. Sun33a , J. E. Sundermann48 , K. Suruliz140 , G. Susinno37a,37b , M. R. Sutton150 , Y. Suzuki65 , M. Svatos126 , S. Swedish169 , M. Swiatlowski144 , I. Sykora145a , T. Sykora128 , D. Ta89 , C. Taccini135a,135b , K. Tackmann42 , J. Taenzer159 , A. Taffard164 , R. Tafirout160a , N. Taiblum154 , H. Takai25 , R. Takashima68 , H. Takeda66 , T. Takeshita141 , Y. Takubo65 , M. Talby84 , A. A. Talyshev108,t , J. Y. C. Tam175 , K. G. Tan87 , J. Tanaka156 , R. Tanaka116 , S. Tanaka132 , S. Tanaka65 , A. J. Tanasijczuk143 , B. B. Tannenwald110 , N. Tannoury21 , S. Tapprogge82 , S. Tarem153 , F. Tarrade29 , G. F. Tartarelli90a , P. Tas128 , M. Tasevsky126 , T. Tashiro67 , E. Tassi37a,37b , A. Tavares Delgado125a,125b , Y. Tayalati136d , F. E. Taylor93 , G. N. Taylor87 , W. Taylor160b , F. A. Teischinger30 , M. Teixeira Dias Castanheira75 , P. Teixeira-Dias76 , K. K. Temming48 , H. Ten Kate30 , P. K. Teng152 , J. J. Teoh117 , S. Terada65 , K. Terashi156 , J. Terron81 , S. Terzo100 , M. Testa47 , R. J. Teuscher159,i , J. Therhaag21 , T. TheveneauxPelzer34 , J. P. Thomas18 , J. Thomas-Wilsker76 , E. N. Thompson35 , P. D. Thompson18 , P. D. Thompson159 , R. J. Thompson83 , A. S. Thompson53 , L. A. Thomsen36 , E. Thomson121 , M. Thomson28 , W. M. Thong87 , R. P. Thun88,* , F. Tian35 , M. J. Tibbetts15 , V. O. Tikhomirov95,ag , Yu. A. Tikhonov108,t , S. Timoshenko97 , E. Tiouchichine84 , P. Tipton177 , S. Tisserant84 , T. Todorov5 , S. Todorova-Nova128 , B. Toggerson7 , J. Tojo69 , S. Tokár145a , K. Tokushuku65 , K. Tollefson89 , L. Tomlinson83 , M. Tomoto102 , L. Tompkins31 , K. Toms104 , N. D. Topilin64 , E. Torrence115 , H. Torres143 , E. Torró Pastor168 , J. Toth84,ah , F. Touchard84 , D. R. Tovey140 , H. L. Tran116 , T. Trefzger175 , L. Tremblet30 , A. Tricoli30 , I. M. Trigger160a , S. TrincazDuvoid79 , M. F. Tripiana12 , W. Trischuk159 , B. Trocmé55 , C. Troncon90a , M. Trottier-McDonald143 , M. Trovatelli135a,135b , P. True89 , M. Trzebinski39 , A. Trzupek39 , C. Tsarouchas30 , J. C.-L. Tseng119 , P. V. Tsiareshka91 , D. Tsionou137 , G. Tsipolitis10 , N. Tsirintanis9 , S. Tsiskaridze12 , V. Tsiskaridze48 , E. G. Tskhadadze51a , I. I. Tsukerman96 , V. Tsulaia15 , S. Tsuno65 , D. Tsybychev149 , A. Tudorache26a , V. Tudorache26a , A. N. Tuna121 , S. A. Tupputi20a,20b , S. Turchikhin98,af , D. Turecek127 , I. Turk Cakir4d , R. Turra90a,90b , P. M. Tuts35 , A. Tykhonov49 , M. Tylmad147a,147b , M. Tyndel130 , K. Uchida21 , I. Ueda156 , R. Ueno29 , M. Ughetto84 , M. Ugland14 , M. Uhlenbrock21 , F. Ukegawa161 , G. Unal30 , A. Undrus25 , G. Unel164 , F. C. Ungaro48 , Y. Unno65 , C. Unverdorben99 , D. Urbaniec35 , P. Urquijo87 , G. Usai8 , A. Usanova61 , L. Vacavant84 , V. Vacek127 , B. Vachon86 , N. Valencic106 , S. Valentinetti20a,20b , A. Valero168 , L. Valery34 , S. Valkar128 , E. Valladolid Gallego168 , S. Vallecorsa49 , J. A. Valls Ferrer168 , W. Van Den Wollenberg106 , P. C. Van Der Deijl106 , R. van der Geer106 , H. van der Graaf106 , R. Van Der Leeuw106 , D. van der Ster30 , N. van Eldik30 , P. van Gemmeren6 , J. Van Nieuwkoop143 , I. van Vulpen106 , M. C. van Woerden30 , M. Vanadia133a,133b , W. Vandelli30 , R. Vanguri121 , A. Vaniachine6 , P. Vankov42 , F. Vannucci79 , G. Vardanyan178 , R. Vari133a , E. W. Varnes7 , T. Varol85 , D. Varouchas79 , A. Vartapetian8 , K. E. Varvell151 , F. Vazeille34 , T. Vazquez Schroeder54 , J. Veatch7 , F. Veloso125a,125c , S. Veneziano133a , A. Ventura72a,72b , D. Ventura85 , M. Venturi170 , N. Venturi159 , A. Venturini23 , V. Vercesi120a , M. Verducci133a,133b , W. Verkerke106 , J. C. Vermeulen106 , A. Vest44 , M. C. Vetterli143,d , O. Viazlo80 , I. Vichou166 , T. Vickey146c,ai , O. E. Vickey Boeriu146c , G. H. A. Viehhauser119 , S. Viel169 , R. Vigne30 , M. Villa20a,20b , M. Villaplana Perez90a,90b , E. Vilucchi47 , M. G. Vincter29 , V. B. Vinogradov64 , J. Virzi15 , I. Vivarelli150 , F. Vives Vaque3 , S. Vlachos10 , D. Vladoiu99 , M. Vlasak127 , A. Vogel21 , M. Vogel32a , P. Vokac127 , G. Volpi123a,123b , M. Volpi87 , H. von der Schmitt100 , H. von Radziewski48 , E. von Toerne21 , V. Vorobel128 , K. Vorobev97 , M. Vos168 , R. Voss30 , J. H. Vossebeld73 , N. Vranjes137 , M. Vranjes Milosavljevic13a , V. Vrba126 , M. Vreeswijk106 , T. Vu Anh48 , R. Vuillermet30 , I. Vukotic31 , Z. Vykydal127 , P. Wagner21 , W. Wagner176 , H. Wahlberg70 , S. Wahrmund44 , J. Wakabayashi102 , J. Walder71 , R. Walker99 , W. Walkowiak142 , R. Wall177 , P. Waller73 , B. Walsh177 , C. Wang152,aj , C. Wang45 , F. Wang174 , H. Wang15 , H. Wang40 , J. Wang42 , J. Wang33a , 123 Eur. Phys. J. C (2014) 74:3071 Page 43 of 48 3071 K. Wang86 , R. Wang104 , S. M. Wang152 , T. Wang21 , X. Wang177 , C. Wanotayaroj115 , A. Warburton86 , C. P. Ward28 , D. R. Wardrope77 , M. Warsinsky48 , A. Washbrook46 , C. Wasicki42 , P. M. Watkins18 , A. T. Watson18 , I. J. Watson151 , M. F. Watson18 , G. Watts139 , S. Watts83 , B. M. Waugh77 , S. Webb83 , M. S. Weber17 , S. W. Weber175 , J. S. Webster31 , A. R. Weidberg119 , P. Weigell100 , B. Weinert60 , J. Weingarten54 , C. Weiser48 , H. Weits106 , P. S. Wells30 , T. Wenaus25 , D. Wendland16 , Z. Weng152,ae , T. Wengler30 , S. Wenig30 , N. Wermes21 , M. Werner48 , P. Werner30 , M. Wessels58a , J. Wetter162 , K. Whalen29 , A. White8 , M. J. White1 , R. White32b , S. White123a,123b , D. Whiteson164 , D. Wicke176 , F. J. Wickens130 , W. Wiedenmann174 , M. Wielers130 , P. Wienemann21 , C. Wiglesworth36 , L. A. M. Wiik-Fuchs21 , P. A. Wijeratne77 , A. Wildauer100 , M. A. Wildt42,ak , H. G. Wilkens30 , J. Z. Will99 , H. H. Williams121 , S. Williams28 , C. Willis89 , S. Willocq85 , A. Wilson88 , J. A. Wilson18 , I. Wingerter-Seez5 , F. Winklmeier115 , B. T. Winter21 , M. Wittgen144 , T. Wittig43 , J. Wittkowski99 , S. J. Wollstadt82 , M. W. Wolter39 , H. Wolters125a,125c , B. K. Wosiek39 , J. Wotschack30 , M. J. Woudstra83 , K. W. Wozniak39 , M. Wright53 , M. Wu55 , S. L. Wu174 , X. Wu49 , Y. Wu88 , E. Wulf35 , T. R. Wyatt83 , B. M. Wynne46 , S. Xella36 , M. Xiao137 , D. Xu33a , L. Xu33b,al , B. Yabsley151 , S. Yacoob146b,am , R. Yakabe66 , M. Yamada65 , H. Yamaguchi156 , Y. Yamaguchi117 , A. Yamamoto65 , K. Yamamoto63 , S. Yamamoto156 , T. Yamamura156 , T. Yamanaka156 , K. Yamauchi102 , Y. Yamazaki66 , Z. Yan22 , H. Yang33e , H. Yang174 , U. K. Yang83 , Y. Yang110 , S. Yanush92 , L. Yao33a , W.-M. Yao15 , Y. Yasu65 , E. Yatsenko42 , K. H. Yau Wong21 , J. Ye40 , S. Ye25 , I.Yeletskikh64 , A. L. Yen57 , E. Yildirim42 , M. Yilmaz4b , R. Yoosoofmiya124 , K. Yorita172 , R. Yoshida6 , K. Yoshihara156 , C. Young144 , C. J. S. Young30 , S. Youssef22 , D. R. Yu15 , J. Yu8 , J. M. Yu88 , J. Yu113 , L. Yuan66 , A. Yurkewicz107 , I. Yusuff28,an , B. Zabinski39 , R. Zaidan62 , A. M. Zaitsev129,aa , A. Zaman149 , S. Zambito23 , L. Zanello133a,133b , D. Zanzi100 , C. Zeitnitz176 , M. Zeman127 , A. Zemla38a , K. Zengel23 , O. Zenin129 , T. Ženiš145a , D. Zerwas116 , G. Zevi della Porta57 , D. Zhang88 , F. Zhang174 , H. Zhang89 , J. Zhang6 , L. Zhang152 , X. Zhang33d , Z. Zhang116 , Z. Zhao33b , A. Zhemchugov64 , J. Zhong119 , B. Zhou88 , L. Zhou35 , N. Zhou164 , C. G. Zhu33d , H. Zhu33a , J. Zhu88 , Y. Zhu33b , X. Zhuang33a , K. Zhukov95 , A. Zibell175 , D. Zieminska60 , N. I. Zimine64 , C. Zimmermann82 , R. Zimmermann21 , S. Zimmermann21 , S. Zimmermann48 , Z. Zinonos54 , M. Ziolkowski142 , G. Zobernig174 , A. Zoccoli20a,20b , M. zur Nedden16 , G. Zurzolo103a,103b , V. Zutshi107 , L. Zwalinski30 1 Department of Physics, University of Adelaide, Adelaide, Australia 2 Physics Department, SUNY Albany, Albany, NY, USA 3 Department of Physics, University of Alberta, Edmonton, AB, Canada 4 (a) Department of Physics, Ankara University, Ankara, Turkey; (b) Department of Physics, Gazi University, Ankara, Turkey; (c) Division of Physics, TOBB University of Economics and Technology, Ankara, Turkey; (d) Turkish Atomic Energy Authority, Ankara, Turkey 5 LAPP, CNRS/IN2P3 and Université de Savoie, Annecy-le-Vieux, France 6 High Energy Physics Division, Argonne National Laboratory, Argonne, IL, USA 7 Department of Physics, University of Arizona, Tucson, AZ, USA 8 Department of Physics, The University of Texas at Arlington, Arlington, TX, USA 9 Physics Department, University of Athens, Athens, Greece 10 Physics Department, National Technical University of Athens, Zografou, Greece 11 Institute of Physics, Azerbaijan Academy of Sciences, Baku, Azerbaijan 12 Institut de Física d’Altes Energies and Departament de Física de la Universitat Autònoma de Barcelona, Barcelona, Spain 13 (a) Institute of Physics, University of Belgrade, Belgrade, Serbia; (b) Vinca Institute of Nuclear Sciences, University of Belgrade, Belgrade, Serbia 14 Department for Physics and Technology, University of Bergen, Bergen, Norway 15 Physics Division, Lawrence Berkeley National Laboratory and University of California, Berkeley, CA, USA 16 Department of Physics, Humboldt University, Berlin, Germany 17 Albert Einstein Center for Fundamental Physics and Laboratory for High Energy Physics, University of Bern, Bern, Switzerland 18 School of Physics and Astronomy, University of Birmingham, Birmingham, UK 19 (a) Department of Physics, Bogazici University, Istanbul, Turkey; (b) Department of Physics, Dogus University, Istanbul, Turkey; (c) Department of Physics Engineering, Gaziantep University, Gaziantep, Turkey 20 (a) INFN Sezione di Bologna, Bologna, Italy; (b) Dipartimento di Fisica e Astronomia, Università di Bologna, Bologna, Italy 21 Physikalisches Institut, University of Bonn, Bonn, Germany 22 Department of Physics, Boston University, Boston, MA, USA 123 3071 Page 44 of 48 Eur. Phys. J. C (2014) 74:3071 23 Department of Physics, Brandeis University, Waltham, MA, USA 24 (a) Universidade Federal do Rio De Janeiro COPPE/EE/IF, Rio de Janeiro, Brazil; (b) Federal University of Juiz de Fora (UFJF), Juiz de Fora, Brazil; (c) Federal University of Sao Joao del Rei (UFSJ), Sao Joao del Rei, Brazil; (d) Instituto de Fisica, Universidade de Sao Paulo, São Paulo, Brazil 25 Physics Department, Brookhaven National Laboratory, Upton, NY, USA 26 (a) National Institute of Physics and Nuclear Engineering, Bucharest, Romania; (b) Physics Department, National Institute for Research and Development of Isotopic and Molecular Technologies, Cluj Napoca, Romania; (c) University Politehnica Bucharest, Bucharest, Romania; (d) West University in Timisoara, Timisoara, Romania 27 Departamento de Física, Universidad de Buenos Aires, Buenos Aires, Argentina 28 Cavendish Laboratory, University of Cambridge, Cambridge, UK 29 Department of Physics, Carleton University, Ottawa, ON, Canada 30 CERN, Geneva, Switzerland 31 Enrico Fermi Institute, University of Chicago, Chicago, IL, USA 32 (a) Departamento de Física, Pontificia Universidad Católica de Chile, Santiago, Chile; (b) Departamento de Física, Universidad Técnica Federico Santa María, Valparaiso, Chile 33 (a) Institute of High Energy Physics, Chinese Academy of Sciences, Beijing, China; (b) Department of Modern Physics, University of Science and Technology of China, Hefei, Anhui, China; (c) Department of Physics, Nanjing University, Nanjing, Jiangsu, China; (d) School of Physics, Shandong University, Jinan, Shandong, China; (e) Physics Department,, Shanghai Jiao Tong University, Shanghai, China 34 Laboratoire de Physique Corpusculaire, Clermont Université and Université Blaise Pascal and CNRS/IN2P3, Clermont-Ferrand, France 35 Nevis Laboratory, Columbia University, Irvington, NY, USA 36 Niels Bohr Institute, University of Copenhagen, Copenhagen, Denmark 37 (a) INFN Gruppo Collegato di Cosenza, Laboratori Nazionali di Frascati, Frascati, Italy; (b) Dipartimento di Fisica, Università della Calabria, Rende, Italy 38 (a) Faculty of Physics and Applied Computer Science, AGH University of Science and Technology, Kraków, Poland; (b) Marian Smoluchowski Institute of Physics, Jagiellonian University, Kraków, Poland 39 The Henryk Niewodniczanski Institute of Nuclear Physics, Polish Academy of Sciences, Kraków, Poland 40 Physics Department, Southern Methodist University, Dallas, TX, USA 41 Physics Department, University of Texas at Dallas, Richardson, TX, USA 42 DESY, Hamburg and Zeuthen, Germany 43 Institut für Experimentelle Physik IV, Technische Universität Dortmund, Dortmund, Germany 44 Institut für Kern- und Teilchenphysik, Technische Universität Dresden, Dresden, Germany 45 Department of Physics, Duke University, Durham, NC, USA 46 SUPA-School of Physics and Astronomy, University of Edinburgh, Edinburgh, UK 47 INFN Laboratori Nazionali di Frascati, Frascati, Italy 48 Fakultät für Mathematik und Physik, Albert-Ludwigs-Universität, Freiburg, Germany 49 Section de Physique, Université de Genève, Geneva, Switzerland 50 (a) INFN Sezione di Genova, Genoa, Italy; (b) Dipartimento di Fisica, Università di Genova, Genova, Italy 51 (a) E. Andronikashvili Institute of Physics, Iv. Javakhishvili Tbilisi State University, Tbilisi, Georgia; (b) High Energy Physics Institute, Tbilisi State University, Tbilisi, Georgia 52 II Physikalisches Institut, Justus-Liebig-Universität Giessen, Giessen, Germany 53 SUPA-School of Physics and Astronomy, University of Glasgow, Glasgow, UK 54 II Physikalisches Institut, Georg-August-Universität, Göttingen, Germany 55 Laboratoire de Physique Subatomique et de Cosmologie, Université Grenoble-Alpes, CNRS/IN2P3, Grenoble, France 56 Department of Physics, Hampton University, Hampton, VA, USA 57 Laboratory for Particle Physics and Cosmology, Harvard University, Cambridge, MA, USA 58 (a) Kirchhoff-Institut für Physik, Ruprecht-Karls-Universität Heidelberg, Heidelberg, Germany; (b) Physikalisches Institut, Ruprecht-Karls-Universität Heidelberg, Heidelberg, Germany; (c) ZITI Institut für technische Informatik, Ruprecht-Karls-Universität Heidelberg, Mannheim, Germany 59 Faculty of Applied Information Science, Hiroshima Institute of Technology, Hiroshima, Japan 60 Department of Physics, Indiana University, Bloomington, IN, USA 61 Institut für Astro- und Teilchenphysik, Leopold-Franzens-Universität, Innsbruck, Austria 123 Eur. Phys. J. C (2014) 74:3071 Page 45 of 48 3071 62 University of Iowa, Iowa City, IA, USA 63 Department of Physics and Astronomy, Iowa State University, Ames, IA, USA 64 Joint Institute for Nuclear Research, JINR Dubna, Dubna, Russia 65 KEK, High Energy Accelerator Research Organization, Tsukuba, Japan 66 Graduate School of Science, Kobe University, Kobe, Japan 67 Faculty of Science, Kyoto University, Kyoto, Japan 68 Kyoto University of Education, Kyoto, Japan 69 Department of Physics, Kyushu University, Fukuoka, Japan 70 Instituto de Física La Plata, Universidad Nacional de La Plata and CONICET, La Plata, Argentina 71 Physics Department, Lancaster University, Lancaster, UK 72 (a) INFN Sezione di Lecce, Lecce, Italy; (b) Dipartimento di Matematica e Fisica, Università del Salento, Lecce, Italy 73 Oliver Lodge Laboratory, University of Liverpool, Liverpool, UK 74 Department of Physics, Jožef Stefan Institute and University of Ljubljana, Ljubljana, Slovenia 75 School of Physics and Astronomy, Queen Mary University of London, London, UK 76 Department of Physics, Royal Holloway University of London, Surrey, UK 77 Department of Physics and Astronomy, University College London, London, UK 78 Louisiana Tech University, Ruston, LA, USA 79 Laboratoire de Physique Nucléaire et de Hautes Energies, UPMC and Université Paris-Diderot and CNRS/IN2P3, Paris, France 80 Fysiska institutionen, Lunds universitet, Lund, Sweden 81 Departamento de Fisica Teorica C-15, Universidad Autonoma de Madrid, Madrid, Spain 82 Institut für Physik, Universität Mainz, Mainz, Germany 83 School of Physics and Astronomy, University of Manchester, Manchester, UK 84 CPPM, Aix-Marseille Université and CNRS/IN2P3, Marseille, France 85 Department of Physics, University of Massachusetts, Amherst, MA, USA 86 Department of Physics, McGill University, Montreal, QC, Canada 87 School of Physics, University of Melbourne, Parkville, VIC, Australia 88 Department of Physics, The University of Michigan, Ann Arbor, MI, USA 89 Department of Physics and Astronomy, Michigan State University, East Lansing, MI, USA 90 (a) INFN Sezione di Milano, Milan, Italy; (b) Dipartimento di Fisica, Università di Milano, Milan, Italy 91 B.I. Stepanov Institute of Physics, National Academy of Sciences of Belarus, Minsk, Republic of Belarus 92 National Scientific and Educational Centre for Particle and High Energy Physics, Minsk, Republic of Belarus 93 Department of Physics, Massachusetts Institute of Technology, Cambridge, MA, USA 94 Group of Particle Physics, University of Montreal, Montreal, QC, Canada 95 P.N. Lebedev Institute of Physics, Academy of Sciences, Moscow, Russia 96 Institute for Theoretical and Experimental Physics (ITEP), Moscow, Russia 97 Moscow Engineering and Physics Institute (MEPhI), Moscow, Russia 98 D.V. Skobeltsyn Institute of Nuclear Physics, M.V. Lomonosov Moscow State University, Moscow, Russia 99 Fakultät für Physik, Ludwig-Maximilians-Universität München, Munich, Germany 100 Max-Planck-Institut für Physik (Werner-Heisenberg-Institut), Munich, Germany 101 Nagasaki Institute of Applied Science, Nagasaki, Japan 102 Graduate School of Science and Kobayashi-Maskawa Institute, Nagoya University, Nagoya, Japan 103 (a) INFN Sezione di Napoli, Naples, Italy; (b) Dipartimento di Fisica, Università di Napoli, Naples, Italy 104 Department of Physics and Astronomy, University of New Mexico, Albuquerque, NM, USA 105 Institute for Mathematics, Astrophysics and Particle Physics, Radboud University Nijmegen/Nikhef, Nijmegen, The Netherlands 106 Nikhef National Institute for Subatomic Physics and University of Amsterdam, Amsterdam, The Netherlands 107 Department of Physics, Northern Illinois University, DeKalb, IL, USA 108 Budker Institute of Nuclear Physics, SB RAS, Novosibirsk, Russia 109 Department of Physics, New York University, New York, NY, USA 110 Ohio State University, Columbus, OH, USA 111 Faculty of Science, Okayama University, Okayama, Japan 112 Homer L. Dodge Department of Physics and Astronomy, University of Oklahoma, Norman, OK, USA 123 3071 Page 46 of 48 Eur. Phys. J. C (2014) 74:3071 113 Department of Physics, Oklahoma State University, Stillwater, OK, USA 114 Palacký University, RCPTM, Olomouc, Czech Republic 115 Center for High Energy Physics, University of Oregon, Eugene, OR, USA 116 LAL, Université Paris-Sud and CNRS/IN2P3, Orsay, France 117 Graduate School of Science, Osaka University, Osaka, Japan 118 Department of Physics, University of Oslo, Oslo, Norway 119 Department of Physics, Oxford University, Oxford, UK 120 (a) INFN Sezione di Pavia, Pavia, Italy; (b) Dipartimento di Fisica, Università di Pavia, Pavia, Italy 121 Department of Physics, University of Pennsylvania, Philadelphia, PA, USA 122 Petersburg Nuclear Physics Institute, Gatchina, Russia 123 (a) INFN Sezione di Pisa, Pisa, Italy; (b) Dipartimento di Fisica E. Fermi, Università di Pisa, Pisa, Italy 124 Department of Physics and Astronomy, University of Pittsburgh, Pittsburgh, PA, USA 125 (a) Laboratorio de Instrumentacao e Fisica Experimental de Particulas-LIP, Lisbon, Portugal; (b) Faculdade de Ciências, Universidade de Lisboa, Lisbon, Portugal; (c) Department of Physics, University of Coimbra, Coimbra, Portugal; (d) Centro de Física Nuclear da Universidade de Lisboa, Lisbon, Portugal; (e) Departamento de Fisica, Universidade do Minho, Braga, Portugal; (f) Departamento de Fisica Teorica y del Cosmos and CAFPE, Universidad de Granada, Granada, Spain; (g) Dep Fisica and CEFITEC of Faculdade de Ciencias e Tecnologia, Universidade Nova de Lisboa, Caparica, Portugal 126 Institute of Physics, Academy of Sciences of the Czech Republic, Prague, Czech Republic 127 Czech Technical University in Prague, Prague, Czech Republic 128 Faculty of Mathematics and Physics, Charles University in Prague, Prague, Czech Republic 129 State Research Center Institute for High Energy Physics, Protvino, Russia 130 Particle Physics Department, Rutherford Appleton Laboratory, Didcot, UK 131 Physics Department, University of Regina, Regina, SK, Canada 132 Ritsumeikan University, Kusatsu, Shiga, Japan 133 (a) INFN Sezione di Roma, Rome, Italy; (b) Dipartimento di Fisica, Sapienza Università di Roma, Rome, Italy 134 (a) INFN Sezione di Roma Tor Vergata, Rome, Italy; (b) Dipartimento di Fisica, Università di Roma Tor Vergata, Rome, Italy 135 (a) INFN Sezione di Roma Tre, Rome, Italy; (b) Dipartimento di Matematica e Fisica, Università Roma Tre, Rome, Italy 136 (a) Faculté des Sciences Ain Chock, Réseau Universitaire de Physique des Hautes Energies-Université Hassan II, Casablanca, Morocco; (b) Centre National de l’Energie des Sciences Techniques Nucleaires, Rabat, Morocco; (c) Faculté des Sciences Semlalia, Université Cadi Ayyad, LPHEA-Marrakech, Marrakech, Morocco; (d) Faculté des Sciences, Université Mohamed Premier and LPTPM, Oujda, Morocco; (e) Faculté des Sciences, Université Mohammed V-Agdal, Rabat, Morocco 137 DSM/IRFU (Institut de Recherches sur les Lois Fondamentales de l’Univers), CEA Saclay (Commissariat à l’Energie Atomique et aux Energies Alternatives), Gif-sur-Yvette, France 138 Santa Cruz Institute for Particle Physics, University of California Santa Cruz, Santa Cruz, CA, USA 139 Department of Physics, University of Washington, Seattle, WA, USA 140 Department of Physics and Astronomy, University of Sheffield, Sheffield, UK 141 Department of Physics, Shinshu University, Nagano, Japan 142 Fachbereich Physik, Universität Siegen, Siegen, Germany 143 Department of Physics, Simon Fraser University, Burnaby, BC, Canada 144 SLAC National Accelerator Laboratory, Stanford, CA, USA 145 (a) Faculty of Mathematics, Physics and Informatics, Comenius University, Bratislava, Slovak Republic; (b) Department of Subnuclear Physics, Institute of Experimental Physics of the Slovak Academy of Sciences, Kosice, Slovak Republic 146 (a) Department of Physics, University of Cape Town, Cape Town, South Africa; (b) Department of Physics, University of Johannesburg, Johannesburg, South Africa; (c) School of Physics, University of the Witwatersrand, Johannesburg, South Africa 147 (a) Department of Physics, Stockholm University, Stockholm, Sweden; (b) The Oskar Klein Centre, Stockholm, Sweden 148 Physics Department, Royal Institute of Technology, Stockholm, Sweden 149 Departments of Physics and Astronomy and Chemistry, Stony Brook University, Stony Brook, NY, USA 150 Department of Physics and Astronomy, University of Sussex, Brighton, UK 151 School of Physics, University of Sydney, Sydney, Australia 123 Eur. Phys. J. C (2014) 74:3071 Page 47 of 48 3071 152 Institute of Physics, Academia Sinica, Taipei, Taiwan 153 Department of Physics, Technion: Israel Institute of Technology, Haifa, Israel 154 Raymond and Beverly Sackler School of Physics and Astronomy, Tel Aviv University, Tel Aviv, Israel 155 Department of Physics, Aristotle University of Thessaloniki, Thessaloniki, Greece 156 International Center for Elementary Particle Physics and Department of Physics, The University of Tokyo, Tokyo, Japan 157 Graduate School of Science and Technology, Tokyo Metropolitan University, Tokyo, Japan 158 Department of Physics, Tokyo Institute of Technology, Tokyo, Japan 159 Department of Physics, University of Toronto, Toronto, ON, Canada 160 (a) TRIUMF, Vancouver, BC, Canada; (b) Department of Physics and Astronomy, York University, Toronto, ON, Canada 161 Faculty of Pure and Applied Sciences, University of Tsukuba, Tsukuba, Japan 162 Department of Physics and Astronomy, Tufts University, Medford, MA, USA 163 Centro de Investigaciones, Universidad Antonio Narino, Bogota, Colombia 164 Department of Physics and Astronomy, University of California Irvine, Irvine, CA, USA 165 (a) INFN Gruppo Collegato di Udine, Sezione di Trieste, Udine, Italy; (b) ICTP, Trieste, Italy; (c) Dipartimento di Chimica, Fisica e Ambiente, Università di Udine, Udine, Italy 166 Department of Physics, University of Illinois, Urbana, IL, USA 167 Department of Physics and Astronomy, University of Uppsala, Uppsala, Sweden 168 Instituto de Física Corpuscular (IFIC) and Departamento de Física Atómica, Molecular y Nuclear and Departamento de Ingeniería Electrónica and Instituto de Microelectrónica de Barcelona (IMB-CNM), University of Valencia and CSIC, Valencia, Spain 169 Department of Physics, University of British Columbia, Vancouver, BC, Canada 170 Department of Physics and Astronomy, University of Victoria, Victoria, BC, Canada 171 Department of Physics, University of Warwick, Coventry, UK 172 Waseda University, Tokyo, Japan 173 Department of Particle Physics, The Weizmann Institute of Science, Rehovot, Israel 174 Department of Physics, University of Wisconsin, Madison, WI, USA 175 Fakultät für Physik und Astronomie, Julius-Maximilians-Universität, Würzburg, Germany 176 Fachbereich C Physik, Bergische Universität Wuppertal, Wuppertal, Germany 177 Department of Physics, Yale University, New Haven, CT, USA 178 Yerevan Physics Institute, Yerevan, Armenia 179 Centre de Calcul de l’Institut National de Physique Nucléaire et de Physique des Particules (IN2P3), Villeurbanne, France a Also at Department of Physics, King’s College London, London, UK b Also at Institute of Physics, Azerbaijan Academy of Sciences, Baku, Azerbaijan c Also at Particle Physics Department, Rutherford Appleton Laboratory, Didcot, UK d Also at TRIUMF, Vancouver, BC, Canada e Also at Department of Physics, California State University, Fresno, CA, USA f Also at Tomsk State University, Tomsk, Russia g Also at CPPM, Aix-Marseille Université and CNRS/IN2P3, Marseille, France h Also at Università di Napoli Parthenope, Naples, Italy i Also at Institute of Particle Physics (IPP), Canada j Also at Department of Physics, St. Petersburg State Polytechnical University, St. Petersburg, Russia k Also at Chinese University of Hong Kong, China l Also at Department of Financial and Management Engineering, University of the Aegean, Chios, Greece m Also at Louisiana Tech University, Ruston, LA, USA n Also at Institucio Catalana de Recerca i Estudis Avancats, ICREA, Barcelona, Spain o Also at Department of Physics, The University of Texas at Austin, Austin TX, USA p Also at Institute of Theoretical Physics, Ilia State University, Tbilisi, Georgia q Also at CERN, Geneva, Switzerland r Also at Ochadai Academic Production, Ochanomizu University, Tokyo, Japan s Also at Manhattan College, New York, NY, USA t Also at Novosibirsk State University, Novosibirsk, Russia 123 3071 Page 48 of 48 Eur. Phys. J. C (2014) 74:3071 u Also at Institute of Physics, Academia Sinica, Taipei, Taiwan v Also at LAL, Université Paris-Sud and CNRS/IN2P3, Orsay, France w Also at Academia Sinica Grid Computing, Institute of Physics, Academia Sinica, Taipei, Taiwan x Also at Laboratoire de Physique Nucléaire et de Hautes Energies, UPMC and Université Paris-Diderot and CNRS/IN2P3, Paris, France y Also at School of Physical Sciences, National Institute of Science Education and Research, Bhubaneswar, India z Also at Dipartimento di Fisica, Sapienza Università di Roma, Rome, Italy aa Also at Moscow Institute of Physics and Technology State University, Dolgoprudny, Russia ab Also at Section de Physique, Université de Genève, Geneva, Switzerland ac Also at International School for Advanced Studies (SISSA), Trieste, Italy ad Also at Department of Physics and Astronomy, University of South Carolina, Columbia, SC, USA ae Also at School of Physics and Engineering, Sun Yat-sen University, Guangzhou, China af Also at Faculty of Physics, M.V. Lomonosov Moscow State University, Moscow, Russia ag Also at Moscow Engineering and Physics Institute (MEPhI), Moscow, Russia ah Also at Institute for Particle and Nuclear Physics, Wigner Research Centre for Physics, Budapest, Hungary ai Also at Department of Physics, Oxford University, Oxford, UK aj Also at Department of Physics, Nanjing University, Jiangsu, China ak Also at Institut für Experimentalphysik, Universität Hamburg, Hamburg, Germany al Also at Department of Physics, The University of Michigan, Ann Arbor, MI, USA am Also at Discipline of Physics, University of KwaZulu-Natal, Durban, South Africa an Also at University of Malaya, Department of Physics, Kuala Lumpur, Malaysia * Deceased 123