Energy Conservation Program: Test Procedures for Walk-In Coolers and Walk-In Freezers
Energy Department · 2011
Read Energy Conservation Program: Test Procedures for Walk-In Coolers and Walk-In Freezers by Energy Department (2011) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/uslaw-fr-c1-2011-8690.txt.
Description
Rule published in the Federal Register on 2011-06-09 by Energy Department. Text from federalregister.gov (official edition: govinfo). [Pages 33631-33639] From the Federal Register Online via the Government Publishing Office [www.gpo.gov] [FR Doc No: C1-2011-8690] ----------------------------------------------------------------------- DEPARTMENT OF ENERGY 10 CFR Part 431 [Docket No. EERE-2008-BT-TP-0014] RIN 1904-AB85 Energy Conservation Program: Test Procedures for Walk-In Coolers and Walk-In Freezers Correction In rule document 2011-8690 appearing on pages 21579-21612 in the issue of Friday.
Catalog record
| CREATOR | Energy Department |
|---|---|
| YEAR | 2011 |
| COLLECTION | LAW |
| FORMAT | TXT |
| FILE SIZE | 36 KB |
| VERSION | 1.0 |
| LICENSE | Public Domain |
| RIGHTS | PUBLIC DOMAIN |
| SOURCE | Federal Register |
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Energy Conservation Program: Test Procedures for Walk-In Coolers and Walk-In Freezers Citation: us:fr:C1-2011-8690 Creator: Energy Department Year: 2011 Source-URL: https://www.federalregister.gov/documents/2011/06/09/C1-2011-8690/energy-conservation-program-test-procedures-for-walk-in-coolers-and-walk-in-freezers Context: Rule published in the Federal Register on 2011-06-09 by Energy Department. Text from federalregister.gov (official edition: govinfo). [Pages 33631-33639] From the Federal Register Online via the Government Publishing Office [www.gpo.gov] [FR Doc No: C1-2011-8690] ----------------------------------------------------------------------- DEPARTMENT OF ENERGY 10 CFR Part 431 [Docket No. EERE-2008-BT-TP-0014] RIN 1904-AB85 Energy Conservation Program: Test Procedures for Walk-In Coolers and Walk-In Freezers Correction In rule document 2011-8690 appearing on pages 21579-21612 in the issue of Friday, April 15, 2011, the regulatory text is being republished below in its entirety due to errors in the equations. PART 431--[CORRECTED] On page 21604, in the third column, in the third paragraph from the top, the regulatory text should read as set forth below: PART 431--ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND INDUSTRIAL EQUIPMENT 0 1. The authority citation for part 431 continues to read as follows: Authority: 42 U.S.C. 6291-6317. 0 2. Section 431.302 is amended by adding, in alphabetical order, new definitions for ``Display door,'' ``Display panel,'' ``Door'', ``Envelope,'' ``K-factor,'' ``Panel,'' ``Refrigerated,'' ``Refrigeration system,'' and ``U-factor'' to read as follows: Sec. 431.302 Definitions concerning walk-in coolers and walk-in freezers. * * * * * Display door means a door designed for product movement, display, or both, rather than the passage of persons. Display panel means a panel that is entirely or partially comprised of glass, a transparent material, or both and is used for display purposes. Door means an assembly installed in an opening on an interior or exterior wall that is used to allow access or close off the opening and that is movable in a sliding, pivoting, hinged, or revolving manner of movement. For walk-in coolers and walk-in freezers, a door includes the door panel, glass, framing materials, door plug, mullion, and any other elements that form the door or part of its connection to the wall. Envelope means-- (1) The portion of a walk-in cooler or walk-in freezer that isolates the interior, refrigerated environment from the ambient, external environment; and (2) All energy-consuming components of the walk-in cooler or walk- in freezer that are not part of its refrigeration system. K-factor means the thermal conductivity of a material. * * * * * Panel means a construction component that is not a door and is used to construct the envelope of the walk-in, i.e., elements that separate the interior refrigerated environment of the walk-in from the exterior. Refrigerated means held at a temperature at or below 55 degrees Fahrenheit using a refrigeration system. Refrigeration system means the mechanism (including all controls and other components integral to the system's operation) used to create the refrigerated environment in the interior of a walk-in cooler or freezer, consisting of: (1) A packaged dedicated system where the unit cooler and condensing unit are integrated into a single piece of equipment; or (2) A split dedicated system with separate unit cooler and condensing unit sections; or (3) A unit cooler that is connected to a multiplex condensing system. U-factor means the heat transmission in a unit time through a unit area of a specimen or product and its boundary air films, induced by a unit temperature difference between the environments on each side. * * * * * 0 3. Section 431.303 is amended by: 0 a. Redesignating paragraph (b) as paragraph (c); 0 b. Adding at the end of the sentence in redesignated paragraph (c)(1), ``and Appendix A to Subpart R of Part 431''. 0 c. Adding new paragraphs (b), (c)(2), (d), and (e) to read as follows. Sec. 431.303 Materials incorporated by reference. * * * * * (b) AHRI. Air-Conditioning, Heating, and Refrigeration Institute, 2111 Wilson Boulevard, Suite 500, Arlington, VA 22201, (703) 600-0366, or http://www.ahrinet.org. (1) AHRI 1250 (I-P)-2009, (``AHRI 1250''), 2009 Standard for Performance Rating of Walk-In Coolers and Freezers, approved 2009, IBR approved for Sec. 431.304. (2) [Reserved] (c) * * * (2) ASTM C1363-05, (``ASTM C1363''), Standard Test Method for Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Box Apparatus, approved May 1, 2005, IBR approved for Appendix A to Subpart R of part 431. (d) CEN. European Committee for Standardization (French: Norme or German: Norm), Avenue Marnix 17, B-1000 Brussels, Belgium, Tel: + 32 2 550 08 11, Fax: + 32 2 550 08 19 or http://www.cen.eu/. (1) DIN EN 13164:2009-02, (``DIN EN 13164''), Thermal insulation products for buildings--Factory made products of extruded polystyrene foam (XPS)--Specification, approved February 2009, IBR approved for Appendix A to Subpart R of part 431. (2) DIN EN 13165:2009-02, (``DIN EN 13165''), Thermal insulation products for buildings--Factory made rigid polyurethane foam (PUR) products--Specification, approved February 2009, IBR approved for Appendix A to Subpart R of part 431. (e) NFRC. National Fenestration Rating Council, 6305 Ivy Lane, Ste. 140, Greenbelt, MD 20770, (301) 589-1776, or http://www.nfrc.org/. (1) NFRC 100-2010[E0A1], (``NFRC 100''), Procedure for Determining Fenestration Product U-factors, approved June 2010, IBR approved for Appendix A to Subpart R of part 431. (2) [Reserved] 0 4. Section 431.304 is amended by redesignating paragraphs (b)(2), (b)(3), (b)(4), and (b)(5) as (b)(1), (b)(2), (b)(3), and (b)(4), respectively, and by adding new paragraphs (b)(5), (b)(6), (b)(7), and (b)(8) to read as follows. Sec. 431.304 Uniform test method for the measurement of energy consumption of walk-in coolers and walk-in freezers. * * * * * (b) * * * (5) Determine the U-factor, conduction load, and energy use of walk-in cooler and walk-in freezer display panels, floor panels, and non-floor panels by conducting the test procedure set forth in Appendix A to this subpart, sections 4.1, 4.2, and 4.3, respectively. (6) Determine the energy use of walk-in cooler and walk-in freezer display doors and non-display doors by conducting the test procedure set forth in Appendix A to this subpart, sections 4.4 and 4.5, respectively. (7) Determine the Annual Walk-in Energy Factor of walk-in cooler and walk-in freezer refrigeration systems by conducting the test procedure set forth in AHRI 1250 (incorporated by reference; see Sec. 431.303). (8) Determine the annual energy consumption of walk-in cooler and walk-in freezer refrigeration systems: [[Page 33632]] (i) For systems consisting of a packaged dedicated system or a split dedicated system, where the condensing unit is located outdoors, by conducting the test procedure set forth in AHRI 1250 and recording the annual energy consumption term in the equation for annual walk-in energy factor in section 7 of AHRI 1250: [GRAPHIC] [TIFF OMITTED] TR09JN11.000 where tj and n represent the outdoor temperature at each bin j and the number of hours in each bin j, respectively, for the temperature bins listed in Table D1 of AHRI 1250. (ii) For systems consisting of a packaged dedicated system or a split dedicated system where the condensing unit is located in a conditioned space, by performing the following calculation: [GRAPHIC] [TIFF OMITTED] TR09JN11.001 where BLH and BLL for refrigerator and freezer systems are defined in sections 6.2.1 and 6.2.2, respectively, of AHRI 1250 and the annual walk-in energy factor is calculated from the results of the test procedures set forth in AHRI 1250. (iii) For systems consisting of a single unit cooler or a set