Read Holtec International's HI-STORE Consolidated Interim Storage Facility for Interim Storage of Spent Nuclear Fuel by Nuclear Regulatory Commission (2018) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/uslaw-fr-2018-15079.txt.

Description

Notice published in the Federal Register on 2018-07-16 by Nuclear Regulatory Commission. Text from federalregister.gov (official edition: govinfo). [Pages 32919-32925] From the Federal Register Online via the Government Publishing Office [www.gpo.gov] [FR Doc No: 2018-15079] ----------------------------------------------------------------------- NUCLEAR REGULATORY COMMISSION [Docket No. 72-1051; NRC-2018-0055] Holtec International's HI-STORE Consolidated Interim Storage Facility for Interim Storage of Spent Nuclear Fuel AGENCY: Nuclear Regulatory Commission. ACTION: License application; opportunity to request a hearing and to petition.

Catalog record

CREATORNuclear Regulatory Commission
YEAR2018
COLLECTIONLAW
FORMATTXT
FILE SIZE43 KB
VERSION1.0
LICENSEPublic Domain
RIGHTSPUBLIC DOMAIN
SOURCEFederal Register

Source: https://www.federalregister.gov/documents/2018/07/16/2018-15079/holtec-internationals-hi-store-consolidated-interim-storage-facility-for-interim-storage-of-spent

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Holtec International's HI-STORE Consolidated Interim Storage Facility for Interim Storage of Spent Nuclear Fuel Citation: us:fr:2018-15079 Creator: Nuclear Regulatory Commission Year: 2018 Source-URL: https://www.federalregister.gov/documents/2018/07/16/2018-15079/holtec-internationals-hi-store-consolidated-interim-storage-facility-for-interim-storage-of-spent Context: Notice published in the Federal Register on 2018-07-16 by Nuclear Regulatory Commission. Text from federalregister.gov (official edition: govinfo). [Pages 32919-32925] From the Federal Register Online via the Government Publishing Office [www.gpo.gov] [FR Doc No: 2018-15079] ----------------------------------------------------------------------- NUCLEAR REGULATORY COMMISSION [Docket No. 72-1051; NRC-2018-0055] Holtec International's HI-STORE Consolidated Interim Storage Facility for Interim Storage of Spent Nuclear Fuel AGENCY: Nuclear Regulatory Commission. ACTION: License application; opportunity to request a hearing and to petition for leave to intervene; order. ----------------------------------------------------------------------- SUMMARY: The U.S. Nuclear Regulatory Commission (NRC) received a license application from Holtec International (Holtec), by letter dated March 30, 2017, as supplemented on April 13, October 6, December 21, and 22, 2017; and February 22, 2018. By this application, Holtec is requesting authorization to construct and operate the HI-STORE Consolidated Interim Storage (CIS) Facility, in Lea County, New Mexico. If the NRC approves the application and issues a license to Holtec, Holtec intends to store up to 8,680 metric tons of uranium (MTU) of commercial spent nuclear fuel in the HI-STORM UMAX Canister Storage System for a 40-year license term. DATES: A request for a hearing or petition for leave to intervene must be filed by September 14, 2018. ADDRESSES: Please refer to Docket ID NRC-2018-0055 when contacting the NRC about the availability of information regarding this document. You may obtain publicly-available information related to this document using any of the following methods: Federal Rulemaking Website: Go to http://www.regulations.gov and search for Docket ID NRC-2018-0055. Address questions about NRC dockets to Jennifer Borges; telephone: 301-287- 9127; email: [email protected]. For technical questions, contact the individual listed in the FOR FURTHER INFORMATION CONTACT section of this document. [[Page 32920]] NRC's Agencywide Documents Access and Management System (ADAMS): You may obtain publicly available documents online in the ADAMS Public Documents collection at http://www.nrc.gov/reading-rm/adams.html. To begin the search, select ``ADAMS Public Documents'' and then select ``Begin Web-based ADAMS Search.'' For problems with ADAMS, please contact the NRC's Public Document Room (PDR) reference staff at 1-800-397-4209, 301-415-4737, or by email to [email protected]. For the convenience of the reader, the ADAMS accession numbers are provided in a table in the ``Availability of Documents'' section of this document. NRC's PDR: You may examine and purchase copies of public documents at the NRC's PDR, Room O1-F21, One White Flint North, 11555 Rockville Pike, Rockville, Maryland 20852. FOR FURTHER INFORMATION CONTACT: Jose R. Cuadrado, Office of Nuclear Material Safety and Safeguards, U.S. Nuclear Regulatory Commission, Washington, DC 20555-0001; telephone: 301-415-0606; email: [email protected]. SUPPLEMENTARY INFORMATION: I. Introduction The NRC received an application from Holtec for a specific license pursuant to part 72 of title 10 of the Code of Federal Regulations (10 CFR), ``Licensing Requirements for the Independent Storage of Spent Nuclear Fuel, High-Level Radioactive Waste, and Reactor-Related Greater Than Class C Waste.'' On March 19, 2018, notice of the NRC's acceptance and docketing of the application and the public availability of the application was provided in the Federal Register (83 FR 12034). Holtec is proposing to construct and operate the HI-STORE Consolidated Interim Storage (CIS) Facility on a large parcel of presently unused land owned by the Eddy-Lea Energy Alliance (ELEA), LLC. The ELEA was formed in 2006 in accordance with enabling legislation passed in New Mexico and consists of an alliance of the city of Carlsbad, Eddy County, the city of Hobbs, and Lea County. The proposed site for the CIS facility is located in southeastern New Mexico in Lea County, 32 miles east of Carlsbad, New Mexico, and 34 miles west of Hobbs, New Mexico. Holtec is proposing to construct and operate Phase 1 of the CIS facility within an approximately 1,040 acre parcel. Holtec is currently requesting authorization to possess and store 500 canisters of spent nuclear fuel (SNF) containing up to 8,680 metric tons of uranium (MTUs), which includes spent uranium-based fuel from commercial nuclear reactors, as well as a small quantity of spent mixed-oxide fuel. If the NRC issues the requested license, Holtec expects to subsequently request additional amendments to the initial license to expand the storage capacity of the facility. In its plans, Holtec proposes expanding the facility in 19 subsequent expansion phases, each for an additional 500 canisters, to be completed over the course of 20 years. Ultimately, Holtec anticipates that approximately 10,000 canisters of SNF would be stored at the CIS facility upon completion of 20 phases. Each phase would require NRC review and approval. According to its application, Holtec intends to only use the HI- STORM UMAX Canister Storage System for storage of spent nuclear fuel canisters at the facility. The HI-STORM UMAX Canister Storage System stores the canister containing SNF entirely below-ground, providing a clear, unobstructed view of the entire CIS facility from any location. II. Opportunity To Request a Hearing and Petition for Leave To Intervene Within 60 days after the date of publication of this notice, any person (petitioner) whose interest may be affected by this action may file a request for a hearing and petition for leave to intervene (petition) with respect to the action. Petitions shall be filed in accordance with the Commission's ``Agency Rules of Practice and Procedure'' in 10 CFR part 2. Interested persons should consult a current copy of 10 CFR part 2. The NRC's regulations are accessible electronically from the NRC Library on the NRC's website at http://www.nrc.gov/reading-rm/doc-collections/cfr/. A copy of the regulations is also available at the NRC's Public Document Room, located at One White Flint North, Room O1-F21, 11555 Rockville Pike (First Floor), Rockville, Maryland 20852. If a petition is filed, the Commission or a presiding officer will rule on the petition and, if appropriate, a notice of a hearing will be issued. As required by 10 CFR 2.309(d) the petition should specifically explain the reasons why intervention should be permitted with particular reference to the following general requirements for standing: (1) The name, address, and telephone number of the petitioner; (2) the nature of the petitioner's right under the Act to be made a party to the proceeding; (3) the nature and extent of the petitioner's property, financial, or other interest in the proceeding; and (4) the possible effect of any decision or order which may be entered in the proceeding on the petitioner's interest. In accordance with 10 CFR 2.309(f), the petition must also set forth the specific contentions which the petitioner seeks to have litigated in the proceeding. Each contention must consist of a specific statement of the issue of law or fact to be raised or controverted. In addition, the petitioner must provide a brief explanation of the bases for the contention and a concise statement of the alleged facts or expert opinion which support the contention and on which the petitioner intends to rely in proving the contention at the hearing. The petitioner must also provide references to the specific sources and documents on which the petitioner intends to rely to support its position on the issue. The petition must include sufficient information to show that a genuine dispute exists with the applicant or licensee on a

Read the complete text