Read The use of Steri-strips™ and quilting sutures for periocular full-thickness skin grafts: Avoiding a Frost suture or bolster by Ahmed Magid Wanas, Raman Malhotra (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/pmc-13614749.txt.
Description
Skin grafts around the eye traditionally need a bolster or a stitch that holds the lid still, both awkward for patients. Ahmed Wanas and Raman Malhotra describe a simpler dressing: quilting sutures that tack the graft down, plus adhesive strips as a splint. They review sixty-seven patients and seventy full-thickness grafts done this way.
Graft survival hit 98.6 percent, and complications ran about fourteen percent. Lid measurements improved clearly for both upper and lower grafts. Three quarters of grafts graded perfect to good on color and edge. Patients needed barely more than one visit in the first six weeks. The 2026 series offers a cheaper, lighter aftercare path.