Iatrogenic ventricular septal defect following papillary muscle premature ventricular contraction ablation: a case report

Maria Luisa Benesch Vidal, Niklas Schenker, Katharina Alina Riedl, Daniel Kalbacher, Andreas Rillig, Andreas Metzner, Leo Bergau, Deepti Ranganathan · 2026

Read Iatrogenic ventricular septal defect following papillary muscle premature ventricular contraction ablation: a case report by Maria Luisa Benesch Vidal, Niklas Schenker, Katharina Alina Riedl, Daniel Kalbacher, Andreas Rillig, Andreas Metzner, Leo Bergau, Deepti Ranganathan (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/pmc-13614262.txt.

Description

Benesch Vidal and colleagues published a case report in twenty twenty-six about a rare harm from a common heart procedure. A seventy-seven-year-old woman had a burn-based procedure, called ablation, to stop extra heartbeats coming from a small muscle inside the heart. The procedure itself went smoothly.

Two months later she returned with worsening breathlessness. Scans showed a new hole between the heart's two lower chambers, exactly where the burn had been placed, letting blood leak the wrong way. Heart imaging confirmed the leak was large enough to matter. After team discussion, doctors closed the hole with a plug device placed through a vessel, and she improved. The authors warn that new heart failure signs after ablation deserve quick imaging, since this late complication can stay hidden.

Catalog record

CREATORMaria Luisa Benesch Vidal, Niklas Schenker, Katharina Alina Riedl, Daniel Kalbacher, Andreas Rillig, Andreas Metzner, Leo Bergau, Deepti Ranganathan
YEAR2026
COLLECTIONPAPERS
FORMATTXT
FILE SIZE19 KB
VERSION1.0
LICENSECC BY 4.0
RIGHTSCC BY
SOURCEEurope PMC

Source: https://europepmc.org/articles/PMC13614262