Impact of dual-layer spectral CT-derived stopping power ratio on single-energy CT-based carbon-ion treatment planning for thoracic cancer
Euntaek Yoon, Sung Hyun Lee, Hyeongmin Jin, Tae Ho Jang, Sungjin Yoon, Hyung Jin Choun, Soon Ho Yoon, Jin Mo Goo, Jong Min Park · 2026
Read Impact of dual-layer spectral CT-derived stopping power ratio on single-energy CT-based carbon-ion treatment planning for thoracic cancer by Euntaek Yoon, Sung Hyun Lee, Hyeongmin Jin, Tae Ho Jang, Sungjin Yoon, Hyung Jin Choun, Soon Ho Yoon, Jin Mo Goo, Jong Min Park (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/pmc-13577390.txt.
Description
Euntaek Yoon and eight co-authors test whether a fancier CT scan improves carbon-ion treatment planning for chest cancers. Their 2026 study uses dual-layer spectral scans from 20 patients. Carbon-ion beams stop at a depth set by tissue stopping power, so small errors in that value shift the dose. Standard planning maps plain CT numbers to stopping power through a lookup table.
The spectral method builds stopping power from atomic number and electron density maps. On a test phantom its error ran 2.83 percent against 5.57 for the standard map. In patients, organ values differed by up to 3.62 percent in the lungs. Recalculated plans shifted beam range by about 0.71 millimeters on average. The authors weigh whether such gains justify new hardware.
Catalog record
| CREATOR | Euntaek Yoon, Sung Hyun Lee, Hyeongmin Jin, Tae Ho Jang, Sungjin Yoon, Hyung Jin Choun, Soon Ho Yoon, Jin Mo Goo, Jong Min Park |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 43 KB |
| VERSION | 1.0 |
| LICENSE | CC BY 4.0 |
| RIGHTS | CC BY |
| SOURCE | Europe PMC |