Read Intramedullary Nailing Versus Plate Fixation for AO/OTA Types 43A and 43B Distal Tibial Fractures: Early Pain Trajectories, 3-Month Ankle Function, and Return to Work in a Retrospective Cohort by Feng-Jun Lan, Chang-Sheng Liao, Huan-Sheng Liu, Dai-Xin Tan, Cheng Long (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/pmc-13566837.txt.
Description
Feng-Jun Lan and co-authors compare two ways of fixing shinbone breaks near the ankle: a rod down the bone's center or a plate screwed on its surface, in a 2026 study. The records cover 87 adults treated at one center from 2019 to 2025, 35 with the rod and 52 with the plate. Pain scores, ankle function at three months, and return to work were tracked.
After adjusting for patient mix, the rod group scored about 2.5 points higher on ankle function and returned to work about 31 days sooner. Pain favored the rod in the first month, then faded to near zero in both groups by six months. Healing failures were rare and alike in both groups. The authors read this as a recovery edge for the rod, not proof it always wins.
Catalog record
| CREATOR | Feng-Jun Lan, Chang-Sheng Liao, Huan-Sheng Liu, Dai-Xin Tan, Cheng Long |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 32 KB |
| VERSION | 1.0 |
| LICENSE | CC BY 4.0 |
| RIGHTS | CC BY |
| SOURCE | Europe PMC |