Structural efficiency of blast furnace steel slag aggregate concrete for strengthening RC flat slabs

Mohamed Ahmed, Mohamed A. Abouelnour, Mohamed Abou-Elmaaty Amin, Mahmoud Zaghlal, Eman Elshamy · 2026

Read Structural efficiency of blast furnace steel slag aggregate concrete for strengthening RC flat slabs by Mohamed Ahmed, Mohamed A. Abouelnour, Mohamed Abou-Elmaaty Amin, Mahmoud Zaghlal, Eman Elshamy (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/pmc-13562655.txt.

Description

Mohamed Ahmed and colleagues test steel slag concrete as a strengthening layer for reinforced concrete flat slabs. Their 2026 study replaces all natural aggregate with blast furnace slag in the overlay material.

Five slabs were loaded statically and compared against fibre polymer, steel-fibre concrete, and high-performance concrete strengthening methods. The slag overlay raised ultimate load by about thirty percent and first-crack load by about sixteen percent. Deflection at failure fell by over half versus the unstrengthened slab. A validated computer model then explored twenty-two configurations varying overlay thickness, slab proportions, and reinforcement corrosion. The authors recommend an overlay of twenty to thirty percent of slab thickness as optimal.

Catalog record

CREATORMohamed Ahmed, Mohamed A. Abouelnour, Mohamed Abou-Elmaaty Amin, Mahmoud Zaghlal, Eman Elshamy
YEAR2026
COLLECTIONPAPERS
FORMATTXT
FILE SIZE76 KB
VERSION1.0
LICENSECC BY 4.0
RIGHTSCC BY
SOURCEEurope PMC