Biomechanical effects of length and angle of the subcutaneous tunnel on epidural catheter stability in a porcine model

Jan Pennig, Sarah N. Schmidt, Axel Schmutz, Johannes Hell · 2026

Read Biomechanical effects of length and angle of the subcutaneous tunnel on epidural catheter stability in a porcine model by Jan Pennig, Sarah N. Schmidt, Axel Schmutz, Johannes Hell (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/pmc-13562554.txt.

Description

Jan Pennig and co-authors test how to keep epidural catheters from slipping in a 2026 study. A catheter that migrates can cause serious harm, above all in patients on blood thinners. Tunneling the line under the skin is one fix; tape and dressings are another. The team varied tunnel length and angle in pig skin and pulled with a motorized rig.

Tunneled catheters let go at under one newton of force, while film dressings and adhesive strips held roughly ten times longer. Tunnel length and angle made no difference. Longer adhesive strips held better than shorter ones. The authors conclude tunneling adds little mechanical security on its own, at least under lab conditions, and adhesive fixation deserves the surgeon's trust.

Catalog record

CREATORJan Pennig, Sarah N. Schmidt, Axel Schmutz, Johannes Hell
YEAR2026
COLLECTIONPAPERS
FORMATTXT
FILE SIZE28 KB
VERSION1.0
LICENSECC BY 4.0
RIGHTSCC BY
SOURCEEurope PMC

Source: https://europepmc.org/articles/PMC13562554

Browse the full library · About the Tower of Babel