A Practical Adjunct for Resolving Valve Sizing Ambiguity in Bicuspid Aortic Valves During Balloon-Expandable TAVR

Alvin HY Ko, Angus SF Chui · 2026

Read A Practical Adjunct for Resolving Valve Sizing Ambiguity in Bicuspid Aortic Valves During Balloon-Expandable TAVR by Alvin HY Ko, Angus SF Chui (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/PMC13531194.txt.

Description

Ko and Chui wrote a 2026 editorial on a practical trick for choosing valve size during transcatheter aortic valve replacement in patients born with a two-leaflet aortic valve. Such anatomy is often tapered and heavily calcified. standard scan-based sizing can leave operators torn between two consecutive valve sizes, risking vessel rupture with the larger or leakage with the smaller.

Ko describes a two-patient series in which operators first inflated a slightly undersized balloon at the valve while injecting contrast dye. In the first case, despite a reassuring balloon test, the larger valve was implanted and expanded poorly at its middle even after further inflation. In the second, the same test pointed the team to the smaller valve, which expanded fully with no rupture or leak. The editorial endorses the balloon observation as a simple tie-breaker algorithm when scans leave sizing genuinely ambiguous.

Catalog record

CREATORAlvin HY Ko, Angus SF Chui
YEAR2026
COLLECTIONPAPERS
FORMATTXT
FILE SIZE8 KB
LICENSEhttps://creativecommons.org/licenses/by/4.0
RIGHTSCC BY
SOURCEEurope PMC

Source: https://europepmc.org/article/MED/PMC13531194