Read Atypical perfusion compromising circulatory arrest during mechanical root replacement and aortic arch replacement with frozen elephant trunk in ACTA2 aortopathy by Durr Al-Hakim, Sorush Rokui, Edward Percy, Joel Price (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/pmc-13526363.txt.
Description
Durr Al-Hakim and co-authors recount a perfusion trap during aortic surgery in a 2026 case report. A man of forty with a genetic aorta disease needed root and arch replacement. Old bypass grafts from earlier repairs still ran through his body. During the planned circulatory arrest, they ambushed the operation.
Blood poured through the patent grafts into the open field, mimicking a steal circuit. The team seized control at the thigh artery, keeping the brain fed while clearing the view. The lesson is planning: map extra bypasses before surgery and prepare clamps, snares, or balloons. Rare anatomy demands rehearsed perfusion plans.