The modified balloon-anchored technique for iliac branch device deployment via ipsilateral femoral access
Chen Xu, Guo-xiong Xu, Xue-feng Gu, Lei Chen, Yi-qi Jin · 2026
Read The modified balloon-anchored technique for iliac branch device deployment via ipsilateral femoral access by Chen Xu, Guo-xiong Xu, Xue-feng Gu, Lei Chen, Yi-qi Jin (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/PMC13523279.txt.
Description
Chen Xu and colleagues describe a modified technique for placing an iliac branch device through the same-side leg artery in a 2026 two-center study. Branch devices preserve blood flow to the internal iliac artery during aneurysm repair, yet standard access routes can fail in patients with short or difficult anatomy. Twenty-three patients treated between 2023 and 2024, in whom the opposite leg route was judged unsuitable, received the balloon-anchored approach.
Deployment succeeded in every case, with the branch artery open and no major leaks on early imaging. At one year, the main device was open in all patients and the bridging stent in nearly all. No related reoperations were needed over a median sixteen months. Two minor complications occurred, supporting the technique as feasible for selected difficult anatomies.
Catalog record
| CREATOR | Chen Xu, Guo-xiong Xu, Xue-feng Gu, Lei Chen, Yi-qi Jin |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 31015 |
| LICENSE | https://creativecommons.org/licenses/by/4.0 |
| RIGHTS | CC BY |
| SOURCE | Europe PMC |