Bone regeneration after transcrestal sinus lift using nanoscale super-hydrophilic versus standard implant surfaces: a single-center, 12-month, parallel controlled clinical trial
Luigi Canullo, Domenico Baldi, Paolo Pesce, Vito Carlo Alberto Caponio, Alessio Triestino, Maria Menini · 2026
Read Bone regeneration after transcrestal sinus lift using nanoscale super-hydrophilic versus standard implant surfaces: a single-center, 12-month, parallel controlled clinical trial by Luigi Canullo, Domenico Baldi, Paolo Pesce, Vito Carlo Alberto Caponio, Alessio Triestino, Maria Menini (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/pmc-13518452.txt.
Description
Luigi Canullo and co-authors test whether a water loving implant surface improves bone regrowth after a sinus lift, in a trial from 2026. Placing an upper tooth implant often needs the sinus floor raised and grafted first. How wettable the implant's surface is may sway how bone rebuilds around it and how well it locks in.
The twelve month trial ran at one center with two matched groups. Both received the same graft and a lift through the tooth socket. One group got standard moderately rough implants, the other got implants with a nanoscale, super water loving surface. X-rays tracked bone volume change and bone level at the implant neck. The comparison tests whether surface chemistry earns a place beside graft choice.
Catalog record
| CREATOR | Luigi Canullo, Domenico Baldi, Paolo Pesce, Vito Carlo Alberto Caponio, Alessio Triestino, Maria Menini |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 38 KB |
| VERSION | 1.0 |
| LICENSE | CC BY 4.0 |
| RIGHTS | CC BY |
| SOURCE | Europe PMC |