Comment on: “Radiation-Free Assessment of Scoliosis: A Reliability and Validity Study for Ultrasound Angles”
Sharath Raj, Vijay Goni · 2026
Read Comment on: “Radiation-Free Assessment of Scoliosis: A Reliability and Validity Study for Ultrasound Angles” by Sharath Raj, Vijay Goni (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/pmc-13473321.txt.
Description
Sharath Raj and Vijay Goni wrote a 2026 comment on a study of ultrasound for scoliosis checks. Scoliosis is a side curve of the spine, often tracked with repeated X-rays in teens. Zhu and co-authors tested whether ultrasound angles can stand in for X-ray angles, sparing patients radiation. Their reliability results looked promising.
Raj and Goni urge care before the method is used for long-term tracking. Strong correlation between two measures does not prove they agree, since a steady offset can hide inside it. The error range also came from repeat scans in one visit, not across months of visits. Small subgroups in a group of 94 add more doubt. They ask for between-visit error data.
Catalog record
| CREATOR | Sharath Raj, Vijay Goni |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 4 KB |
| VERSION | 1.0 |
| LICENSE | CC BY 4.0 |
| RIGHTS | CC BY |
| SOURCE | Europe PMC |