Oral Fine Motor Control in Patients With Anterior Maxillary Single Implants, Freestanding Teeth and Teeth Connected in 3‐Unit Bridges: An Experimental In Vivo Study
Nicole Winitsky, Aron Naimi‐Akbar, Jan‐Ivan Smedberg, Anastasios Grigoriadis · 2026
Read Oral Fine Motor Control in Patients With Anterior Maxillary Single Implants, Freestanding Teeth and Teeth Connected in 3‐Unit Bridges: An Experimental In Vivo Study by Nicole Winitsky, Aron Naimi‐Akbar, Jan‐Ivan Smedberg, Anastasios Grigoriadis (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/pmc-13446234.txt.
Description
Nicole Winitsky and three co-authors test fine mouth control in patients with a single front tooth implant. Each patient did a hold and split task twice, once with a small fixed bridge and once with the implant. Four tooth spots were tested in all.
Control at the implant was worse than at a free tooth on most scores, and much like control at the fake tooth in a bridge. Linking a tooth in a bridge did not hurt control. The work helps dentists set fair hopes for how implants feel in fine mouth tasks.
Catalog record
| CREATOR | Nicole Winitsky, Aron Naimi‐Akbar, Jan‐Ivan Smedberg, Anastasios Grigoriadis |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 30 KB |
| VERSION | 1.0 |
| LICENSE | CC BY 4.0 |
| RIGHTS | CC BY |
| SOURCE | Europe PMC |