Inadvertent dislodgement of a biliary metallic stent during duodenal stent placement
Hidehito Sumiya, Yoshihide Kanno, Shinsuke Koshita, Takahisa Ogawa, Hiroaki Kusunose, Toshitaka Sakai, Kei Ito · 2026
Read Inadvertent dislodgement of a biliary metallic stent during duodenal stent placement by Hidehito Sumiya, Yoshihide Kanno, Shinsuke Koshita, Takahisa Ogawa, Hiroaki Kusunose, Toshitaka Sakai, Kei Ito (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/PMC13441500.txt.
Description
Hidehito Sumiya and colleagues report the first known case of a bile duct stent knocked loose while placing a duodenal stent, publishing in 2026. Their patient, an 81-year-old woman with a pancreatic neuroendocrine tumour, already carried a covered metal biliary stent for drainage. A malignant narrowing then blocked her duodenum, and a second stent was planned. The scope could pass only partway, so the delivery system advanced over a guidewire.
The wire apparently threaded the mesh at the biliary stent's lower end and dragged it downward into the duodenum. The team withdrew the delivery system without deploying, avoiding trapped or clashing stents. Since the bile duct opening could not be seen, they cannulated under X-ray guidance with a novel rotatable cutting tool and placed a plastic stent. The duodenal stent then followed successfully, and the case is presented as an endoscopically rescued first.
Catalog record
| CREATOR | Hidehito Sumiya, Yoshihide Kanno, Shinsuke Koshita, Takahisa Ogawa, Hiroaki Kusunose, Toshitaka Sakai, Kei Ito |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 3 KB |
| LICENSE | https://creativecommons.org/licenses/by/4.0 |
| RIGHTS | CC BY |
| SOURCE | Europe PMC |