Development of colloidal gold and carbon immunochromatographic strips for rapid detection of PDCoV

Chenlin Hao, Mengxiao Xu, Tong Bu, Bingqian Zhang, Zhiyang Ran, Xueshi Niu, Zhihui Chen, Xiaohui Jin, Yue Zhang, Zhanyong Wei, Honglei Zhang · 2026

Read Development of colloidal gold and carbon immunochromatographic strips for rapid detection of PDCoV by Chenlin Hao, Mengxiao Xu, Tong Bu, Bingqian Zhang, Zhiyang Ran, Xueshi Niu, Zhihui Chen, Xiaohui Jin, Yue Zhang, Zhanyong Wei, Honglei Zhang (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/PMC13427578.txt.

Introduction

Chenlin Hao and colleagues report, in 2026, quick farm-side test strips for a pig coronavirus that causes severe diarrhea in newborn piglets. Porcine deltacoronavirus spreads fast in herds and costs the swine industry heavily. Lab testing confirms cases but takes time and equipment most farms lack. The team built strip tests much like home pregnancy kits, using either gold particles or black carbon particles.

Both strips picked up the virus in diluted samples and ignored three related pig viruses. On 137 stool samples from farms, the gold strip agreed with standard lab tests in about 93 cases out of 100. The carbon strip topped 88 percent agreement and marks a first use of carbon in this kind of viral test. Faster answers can help farmers isolate sick animals sooner.

Catalog record

CREATORChenlin Hao, Mengxiao Xu, Tong Bu, Bingqian Zhang, Zhiyang Ran, Xueshi Niu, Zhihui Chen, Xiaohui Jin, Yue Zhang, Zhanyong Wei, Honglei Zhang
YEAR2026
COLLECTIONPAPERS
FORMATTXT
FILE SIZE32378
LICENSEhttps://creativecommons.org/licenses/by/4.0
RIGHTSCC BY
SOURCEEurope PMC

Source: https://europepmc.org/article/MED/PMC13427578

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Development of colloidal gold and carbon immunochromatographic strips for rapid detection of PDCoV Authors: Chenlin Hao, Mengxiao Xu, Tong Bu, Bingqian Zhang, Zhiyang Ran, Xueshi Niu, Zhihui Chen, Xiaohui Jin, Yue Zhang, Zhanyong Wei, Honglei Zhang Published: 2026 ABSTRACT SummaryPorcine deltacoronavirus (PDCoV) is an enteric coronavirus that causes diarrhea in suckling piglets, leading to serious economic losses in the swine industry. In this study, we report the development of competitive immunochromatographic strips for PDCoV detection using both colloidal gold and carbon nanoparticles, which also represents the novel reported application of carbon nanoparticles in a viral immunochromatographic assay. The established strips had visual detection limits of 1:128 (gold) and 1:64 (carbon) at 1 × 108 TCID50/mL. Both assays showed excellent specificity, exhibiting no cross-reactivity with porcine epidemic diarrhea virus (PEDV), transmissible gastroenteritis virus (TGEV), or other viruses. Testing 137 clinical fecal samples showed that gold strips had 92.7% agreement with both RT-PCR and western blot, while carbon strips reached over 88%. These results demonstrate that gold- and carbon-nanoparticle-based immunochromatographic strips hold great potential for the rapid and sensitive detection of PDCoV, facilitating timely disease diagnosis and prevention. Introduction As a novel porcine intestinal coronavirus of the genus Deltacoronavirus, porcine deltacoronavirus (PDCoV) shows a particular severity in newborn piglets, leading to acute diarrhea, vomiting, dehydration, and even death.1,2 Since its emergence in 2012 and a notable outbreak in the United States in 2014, PDCoV has spread to multiple regions including South Korea, Japan, Thailand, and China, resulting in substantial economic damage to the global swine industry.3,4,5,6 Experimental studies have shown that PDCoV can infect mice, chickens, calves, and turkey poults.1,7,8,9 Furthermore, its detection in the plasma of Haitian children in 2021 demonstrated its potential for cross-species transmission.10 PDCoV is a single-stranded positive-sense RNA virus that encodes four structural proteins: spike (S), membrane (M), envelope (E), and nucleocapsid (N).11,12 Among these, the N protein is highly immunogenic and abundantly expressed during viral infection. Due to its high conservation, it is frequently employed as a target antigen for coronavirus detection.13 Therefore, this study aimed to develop a rapid, highly sensitive, and cost-effective PDCoV detection method based on the N protein to promote its prevention and control. Epidemiological investigation revealed that the co-infections of PDCoV with porcine epidemic diarrhea virus (PEDV) and porcine sapelovirus (PSV) were highly prevalent in swine herds.14,15 Such co-infections are likely to aggravate disease severity, complicate clinical presentations, and increase the difficulty of diagnosis and treatment. Currently, PDCoV detection relies on laboratory diagnostic techniques. These methods primarily include molecular biological detection based on viral genetic material analysis, such as RT-PCR and real-time quantitative PCR,16,17 as well as serological detection methods that assess host immune responses, including ELISA and virus neutralization tests.18,19,20 Although RT-PCR remains the preferred method for diagnosing coronavirus infections due to its high sensitivity and broad applicability, it typically requires prolonged detection time, sophisticated bench-top equipment, and professionally trained technicians. These requirements hinder its application in on-site farm detection.21,22 The immunochromatographic assay (ICA) was first proposed by Faulk and Taylor in 1971 and developed as a rapid diagnostic technology in the 1990s.23 With advancements in nanotechnology, various nanomaterials and detection strategies have been successfully incorporated into ICA platforms.24 Gold nanoparticles (Au NPs) are favored for their cost-effectiveness, facile synthesis, operational simplicity, low sample consumption, and stability, establishing them as the most widely employed labels in ICA strips.25,26 Carbon nanoparticles (C NPs) are also effective labels, with the advantages of scalable, low-cost industrial production and clear color development. Gold and carbon nanoparticles have been successfully employed as labels in ICA strips.27 The minimal sample preparation, user-friendly format, low cost, and speed of ICA strips make it a highly promising point-of-care testing (POCT) platform for rapid on-site virus detection. In this study, we selected the N protein as the detection antigen and employed gold and carbon nanoparticles conjugated with an anti-PDCoV monoclonal antibody (mAb) as probes to construct two types of competitive ICA strips. Key parameters in the ICA process, including the coating concentration of the test line (T-line) protein, antibody labeling amount, and color development time, were optimized. Finally, the developed test strips demonstrated high specificity and sensitivity. This work demonstrates the application of carbon nanoparticle probes for coronavirus detection, offering important data and a theoretical basis for diagnostic kit development. Results Purification of recombinant PDCoV N and preparation of anti-PDCoV-N mAb 6B7 Following the principle depicted in the schematic representation of the ICA strip (Figure 1), we first prepared the PDCoV N protein and anti-PDCoV-N mAb 6B7 used in the strip. The recombinant N protein was successfully expressed in the Escherichia coli Rosetta strain. The SDS-PAGE analysis showed that N protein was detected in the supernatant of the IPTG-induced E. coli (Figure 2A, lane 2). The molecular weight of the expressed N protein was 53 KDa, which was consistent with the predicted target protein size. N protein was then purified by Ni-NTA agarose column with the final concentration of 1 mg/mL (Figure 2B, lane 8). Western blot results showed that the recombinant N protein could be specifically recognized by PDCoV positive serum, which had good reactionogenicity (Figure 2C). Purified mAb 6B7 were analyzed by IFA (Figure 2D) and western blot (Figure 2E), which confirmed that the mAbs specifically reacted with PDCoV.Figure 1The schematic representation of the ICA stripThe schematic illustration (A) and detection principle of PDCoV immunochromatographic test strips (B).Figure 2Preparation of the PDCoV N protein and validation of the Anti-PDCoV-N mAb 6B7(A) Detection of PDCoV N recombinant protein expression by SDS-PAGE. M: protein marker; lane 1: after induction; lane 2: supernatant parts post-lysing; lane 3: precipitation parts post-lysing.(B) SDS-PAGE analysis of purified PDCoV N recombinant protein. Lane 1: percolate; lane 2–6: Ni column elution buffer 1; lane 7–8: Ni column elution buffer 2.(C) Western blot analysis of the reactivity of PDCoV N recombinant protein. IFA (D) and western blot (E) identification of the reactivity between Anti-PDCoV-N mAb 6B7 and PDCoV. Anti-PDCoV-N mAb 6B7 recognized the nucleocapsid protein in PDCoV-infected LLC-PK1 cells. The uninfected LLC-PK1 cells were used as mock. Scale bar: 150 μm. The schematic representation of the ICA strip The schematic illustration (A) and detection principle of PDCoV immunochromatographic test strips (B). Preparation of the PDCoV N protein and validation of the Anti-PDCoV-N mAb 6B7 (A) Detection of PDCoV N recombinant protein expression by SDS-PAGE. M: protein marker; lane 1: after induction; lane 2: supernatant parts post-lysing; lane 3: precipitation parts post-lysing. (B) SDS-PAGE analysis of purified PDCoV N recombinant protein. Lane 1: percolate; lane 2–6: Ni column elution buffer 1; lane 7–8: Ni column elution buffer 2. (C) Western blot analysis of the reactivity of PDCoV N recombinant protein. IFA (D) and western blot (E) identification of the reactivity between Anti-PDCoV-N mAb 6B7 and PDCoV. Anti-PDCoV-N mAb 6B7 recognized the nucleocapsid protein in PDCoV-infected LLC-PK1 cells. The uninfected LLC-PK1 cells were used as mock. Scale bar: 150 μm. Characterization of gold nanoparticles Au NPs were successfully synthesized via the trisodium citrate reduction method. The prepared solution was clear, homogeneous, and exhibited a stable wine red (Figure 3A). UV-visible spectrophotometer showed a single, sharp absorption peak at approximately 521 nm, indicating the formation of monodisperse and stable nanoparticles. Based on the established correlation between the absorption maximum

Read the complete text