Balloon-Assisted Distal Control for Open Thoracoabdominal Aortic Repair After Endovascular Aortic Repair

Sei Yasunaga, Tomoaki Kudo, Natsumi Horikawa, Sawaka Tanabe, Yukihiro Noda, Atsushi Takamori, Narihisa Yamada, Shinya Fukui · 2026

Read Balloon-Assisted Distal Control for Open Thoracoabdominal Aortic Repair After Endovascular Aortic Repair by Sei Yasunaga, Tomoaki Kudo, Natsumi Horikawa, Sawaka Tanabe, Yukihiro Noda, Atsushi Takamori, Narihisa Yamada, Shinya Fukui (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/pmc-13420651.txt.

Description

Yasunaga and co-authors describe a surgical technique for controlling blood flow during open repair of a chest-and-abdomen aortic aneurysm. Their patient was a man whose aorta had earlier been treated from inside with a stent graft. Clamping the old graft directly looked difficult. So they used inflatable occlusion balloons to seal the aorta from within.

The patient was a 76-year-old man whose earlier repair had developed a pseudoaneurysm, a contained leak beside the original stent. Guided by X-ray imaging, the team placed balloons into each graft limb through leg artery sheaths. Blood kept flowing to the legs through side branches during the operation. A composite graft bridged the size mismatch, and an inner cuff stopped bleeding at the lower join. He survived without major complications. Scans at 12 months showed no recurrence.

Catalog record

CREATORSei Yasunaga, Tomoaki Kudo, Natsumi Horikawa, Sawaka Tanabe, Yukihiro Noda, Atsushi Takamori, Narihisa Yamada, Shinya Fukui
YEAR2026