Read Assessment of dose distribution in pancreatic SABR in the presence of a metallic biliary stent using Monte Carlo modeling by Ahmad Abbas, Owen Nicholas, Richard P Hugtenburg (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/PMC13389806.txt.

Description

Abbas and colleagues used Monte Carlo modeling in 2026 to check radiation dose accuracy for pancreatic cancer treatment when a metal bile duct stent is present. Patients often carry these self-expanding stents for blocked bile flow, and their dense alloy bends CT scan readings, which can throw off the dose plans made by standard software. The team rechecked two treated patients whose plans used focused high-dose radiation in five sessions.

A new outlining method that splits the hollow stent core from its metal wall shrank the modeled stent size and fixed much of the scan error. Standard simulation overstated tumor dose by about 15 percent. The planning software understated dose beside the stent by up to about 12 percent and understated dose to the nearby duodenum, the first stretch of small bowel, by a similar margin. The authors say stent-aware modeling should be routine in such plans.

Catalog record

CREATORAhmad Abbas, Owen Nicholas, Richard P Hugtenburg
YEAR2026
COLLECTIONPAPERS
FORMATTXT
FILE SIZE44 KB
LICENSEhttps://creativecommons.org/licenses/by/4.0
RIGHTSCC BY
SOURCEEurope PMC

Source: https://europepmc.org/article/MED/PMC13389806

Browse the full library · About the Tower of Babel