Interatrial conduction delay in a young woman mimicking complete atrioventricular block

Vito Mustapić, Martin Manninger, Daniel Scherr, Stefan Kurath-Koller, Kristijan Šipoš, Janko Szavits Nossan · 2026

Read Interatrial conduction delay in a young woman mimicking complete atrioventricular block by Vito Mustapić, Martin Manninger, Daniel Scherr, Stefan Kurath-Koller, Kristijan Šipoš, Janko Szavits Nossan (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/pmc-13379333.txt.

Description

Vito Mustapić and five co-authors reported a 2026 case where two heart chambers fell out of sync, faking a total block. A 31-year-old woman, after two mitral valve surgeries and an ablation in her right upper chamber, was sent for a pacemaker: her monitor seemed to show complete heart block. The true fault lay between the two upper chambers, whose main connecting cable can be hurt by surgery or ablation.

When the left chamber fires late or independently, tracings can mimic block while the lower chambers still conduct normally. A full electrical study of her heart showed the node between chambers working fine. The teaching point: prove true block with such a study before implanting a pacemaker.

Catalog record

CREATORVito Mustapić, Martin Manninger, Daniel Scherr, Stefan Kurath-Koller, Kristijan Šipoš, Janko Szavits Nossan
YEAR2026
COLLECTIONPAPERS
FORMATTXT
FILE SIZE9 KB
VERSION1.0
LICENSECC BY 4.0
RIGHTSCC BY
SOURCEEurope PMC

Source: https://europepmc.org/articles/PMC13379333

Browse the full library · About the Tower of Babel