Learning from a pitfall: Atrial septostomy in LV failure under VA-ECMO for pulmonary hypertension

Camille Wirth, Pierre De Normandie, Sebastien Hascoet, Elie Fadel, François Stephan · 2026

Read Learning from a pitfall: Atrial septostomy in LV failure under VA-ECMO for pulmonary hypertension by Camille Wirth, Pierre De Normandie, Sebastien Hascoet, Elie Fadel, François Stephan (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/PMC13281321.txt.

Description

Camille Wirth and colleagues shared a 2026 case report on a heart fix that backfired in a very sick patient. The patient was on a heart and lung support machine for severe lung artery pressure. The heart then weakened under stress, and fluid backed up into the lungs. Doctors made a small hole between the heart's upper chambers to drain the pressure. The step is used to ease lung pressure in some patients and to unload the heart in others.

Here it did the reverse. Blood slipped the wrong way through the hole, starving the body of oxygen. Pressure also loaded the weak heart further, and the patient got worse. The authors say the balance of pressures on each side of the heart decides whether the hole helps or harms. They urge great care before using it in like cases.

Catalog record

CREATORCamille Wirth, Pierre De Normandie, Sebastien Hascoet, Elie Fadel, François Stephan
YEAR2026
COLLECTIONPAPERS
FORMATTXT
FILE SIZE14442
LICENSEhttps://creativecommons.org/licenses/by/4.0
RIGHTSCC BY
SOURCEEurope PMC

Source: https://europepmc.org/article/MED/PMC13281321

Browse the full library · About the Tower of Babel