Aberrant Right Subclavian Artery Causing Dampening of the Right Radial Arterial Cannula Tracing Following Transesophageal Echocardiography Probe Insertion
Osama Elazzouny, Joseph D. Tobias, Ibrahim Abdullah · 2026
Read Aberrant Right Subclavian Artery Causing Dampening of the Right Radial Arterial Cannula Tracing Following Transesophageal Echocardiography Probe Insertion by Osama Elazzouny, Joseph D. Tobias, Ibrahim Abdullah (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/pmc-13278703.txt.
Description
Osama Elazzouny, Joseph D Tobias, and Ibrahim Abdullah report a 2026 case where a hidden vessel variant surfaced during heart surgery. A six-month-old girl with Down syndrome was having a heart defect repaired. An ultrasound probe passed into her food pipe to watch the heart during the operation.
As the probe went in, the pressure trace from her right wrist line flattened unexpectedly. Imaging then revealed an aberrant right subclavian artery running behind the food pipe. The probe had pressed on the misplaced vessel and cut its flow signal. Such variants usually cause no symptoms at all. The authors urge teams to consider vessel anomalies when monitoring traces change without explanation.
Catalog record
| CREATOR | Osama Elazzouny, Joseph D. Tobias, Ibrahim Abdullah |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 12 KB |
| VERSION | 1.0 |
| LICENSE | CC BY 4.0 |
| RIGHTS | CC BY |
| SOURCE | Europe PMC |