Improved immediate postoperative T4-L1 hip axis with use of pre-contoured patient-specific rods versus surgeon-contoured rods in adolescent idiopathic scoliosis
Sahir S Jabbouri, Peter Joo, Anthony Seddio, Dominick Tuason · 2026
Read Improved immediate postoperative T4-L1 hip axis with use of pre-contoured patient-specific rods versus surgeon-contoured rods in adolescent idiopathic scoliosis by Sahir S Jabbouri, Peter Joo, Anthony Seddio, Dominick Tuason (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/pmc-13263568.txt.
Description
Sahir S Jabbouri and colleagues tested in 2026 whether factory pre-bent rods beat rods bent by the surgeon during scoliosis correction in teenagers. Alignment of the mid-spine against the hips right after surgery predicts later mechanical trouble in adults. Their single-surgeon series compared 33 pre-contoured cases with 40 surgeon-contoured cases.
Immediately after surgery, the pre-contoured group hit the target alignment window far more often, about eighty-two percent against forty-three. By the last follow-up, averaging well over a year, the gap had narrowed and lost statistical force. The groups matched beforehand on curve type, levels fused, and starting measurements. Neither arm showed a clear edge in staying near the ideal pelvic angle. Too few complications occurred to judge hardware failure. The authors claim an early alignment win that may fade with time.
Catalog record
| CREATOR | Sahir S Jabbouri, Peter Joo, Anthony Seddio, Dominick Tuason |
|---|---|
| YEAR | 2026 |