Synoptic Reporting Improves Quality of Endobronchial Ultrasound (EBUS): An Australian Multicentre Study
Ashleigh Witt, Nicole M. Rankin, Hanson Siu, Nicholas Wilsmore, Shaun Yo, Christopher Lyne, Kexin Sun, Kanishka Rangamuwa, Tracy Leong, Ashleigh Hocking, Shankar Siva, Daniel P. Steinfort · 2026
Read Synoptic Reporting Improves Quality of Endobronchial Ultrasound (EBUS): An Australian Multicentre Study by Ashleigh Witt, Nicole M. Rankin, Hanson Siu, Nicholas Wilsmore, Shaun Yo, Christopher Lyne, Kexin Sun, Kanishka Rangamuwa, Tracy Leong, Ashleigh Hocking, Shankar Siva, Daniel P. Steinfort (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/pmc-13204654.txt.
Description
Ashleigh Witt and co-authors test whether structured reporting improves a lung staging procedure in Australian hospitals, in work from 2026. Endobronchial ultrasound guides the sampling of chest lymph nodes in lung cancer care, but free-text reports often leave gaps.
Five hospitals switched to synoptic, checklist-style reports for three months and compared results with the prior three months. Complete staging jumped from about 18 percent to 87 percent of procedures. More lymph nodes were sampled per procedure, more normal-looking nodes were checked, and hidden metastases that scans missed were found more often, rising from 3 to nearly 12 percent. Report completeness improved across most required items.
Catalog record
| CREATOR | Ashleigh Witt, Nicole M. Rankin, Hanson Siu, Nicholas Wilsmore, Shaun Yo, Christopher Lyne, Kexin Sun, Kanishka Rangamuwa, Tracy Leong, Ashleigh Hocking, Shankar Siva, Daniel P. Steinfort |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 23 KB |
| VERSION | 1.0 |
| LICENSE | CC BY 4.0 |
| RIGHTS | CC BY |
| SOURCE | Europe PMC |