AI detection of knee joint effusion from radiographs: Comparative accuracy of two commercial algorithms
Jarno T. Huhtanen, Mikko Nyman, Roberto Blanco Sequeiros, Seppo K. Koskinen, Tomi K. Pudas, Sami Kajander, Pekka Niemi, Hannu J. Aronen, Jussi Hirvonen · 2026
Read AI detection of knee joint effusion from radiographs: Comparative accuracy of two commercial algorithms by Jarno T. Huhtanen, Mikko Nyman, Roberto Blanco Sequeiros, Seppo K. Koskinen, Tomi K. Pudas, Sami Kajander, Pekka Niemi, Hannu J. Aronen, Jussi Hirvonen (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/pmc-13186055.txt.
Description
Jarno Huhtanen and co-authors compare, in 2026, two commercial artificial intelligence tools that look for fluid in the knee on X-rays. Extra fluid can signal injury even when bones look normal. The team gathered one hundred twenty-three side-view knee images and compared both tools against two radiologists, with a tie-breaker.
Fluid was present in just over half the images. One tool missed many cases but never raised a false alarm, while the other caught more cases with a few false alarms and higher overall accuracy. Agreement between the two tools was moderate. Adding fluid detection to fracture checks improved sensitivity, the authors note.
Catalog record
| CREATOR | Jarno T. Huhtanen, Mikko Nyman, Roberto Blanco Sequeiros, Seppo K. Koskinen, Tomi K. Pudas, Sami Kajander, Pekka Niemi, Hannu J. Aronen, Jussi Hirvonen |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 27 KB |
| VERSION | 1.0 |
| LICENSE | CC BY 4.0 |
| RIGHTS | CC BY |
| SOURCE | Europe PMC |