Management of Mixed Mechanism Glaucoma Secondary to NewColorIris Implant Using an Ab Externo Xen Gel Stent
Roshun Sangani, Param Shukla, Miriam M. Habiel · 2026
Read Management of Mixed Mechanism Glaucoma Secondary to NewColorIris Implant Using an Ab Externo Xen Gel Stent by Roshun Sangani, Param Shukla, Miriam M. Habiel (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/pmc-13156467.txt.
Description
Roshun Sangani, Param Shukla, and Miriam Habiel report a glaucoma rescue after a cosmetic iris implant went wrong. A 42-year-old woman with implants in both eyes came to the emergency room with corneal failure and mixed mechanism glaucoma in her left eye, caused by the implant chafing the iris. The implant was removed, yet her eye pressure stayed high afterward.
An off-label Xen Gel Stent, placed from outside the eye, then brought pressures under control. She needed no extra glaucoma drops for 13 months and kept a look she was happy with. The authors propose the stent as a safe option for implant-related glaucoma.
Catalog record
| CREATOR | Roshun Sangani, Param Shukla, Miriam M. Habiel |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 16 KB |
| VERSION | 1.0 |
| LICENSE | CC BY 4.0 |
| RIGHTS | CC BY |
| SOURCE | Europe PMC |