Mechanical Performance of a Monolithic 3D-Printed Orthodontic Bracket–Crown System: An In-Vitro Study †
Selcen Eser Mısır, Serkan Görgülü, Simel Ayyıldız, Gökhan Serhat Duran, Kübra Gülnur Topsakal · 2026
Read Mechanical Performance of a Monolithic 3D-Printed Orthodontic Bracket–Crown System: An In-Vitro Study † by Selcen Eser Mısır, Serkan Görgülü, Simel Ayyıldız, Gökhan Serhat Duran, Kübra Gülnur Topsakal (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/pmc-13117730.txt.
Description
Mısır, Görgülü, Ayyıldız, Duran and Topsakal test a one-piece printed bracket and crown system for teeth in lab work listed for 2026. The design joins the bracket or tube right into a custom metal coping, with no glue joint.
The team loaded three groups of samples until they gave way: the new one-piece group, crowns with bonded parts, and natural teeth with bonded parts. The one-piece group showed the highest resistance, though values varied widely. All groups stayed above the accepted clinical floor. The authors say the design may help when normal bonding is not an option.
Catalog record
| CREATOR | Selcen Eser Mısır, Serkan Görgülü, Simel Ayyıldız, Gökhan Serhat Duran, Kübra Gülnur Topsakal |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 27 KB |
| VERSION | 1.0 |
| LICENSE | CC BY 4.0 |
| RIGHTS | CC BY |
| SOURCE | Europe PMC |